Acessibilidade / Reportar erro
This document is related to:

Reply to: Behavior of lung ultrasound findings during spontaneous breathing trial

First, we would like to thank Drs Blanco and Esquinas for their valuable comments. Indeed, bedside ultrasound became a foremost tool in daily intensive care unit management. International guidelines provide compelling evidence of its benefits and required skills.(11 Volpicelli G, Elbarbary M, Blaivas M, Lichtenstein DA, Mathis G, Kirkpatrick AW, Melniker L, Gargani L, Noble VE, Via G, Dean A, Tsung JW, Soldati G, Copetti R, Bouhemad B, Reissig A, Agricola E, Rouby JJ, Arbelot C, Liteplo A, Sargsyan A, Silva F, Hoppmann R, Breitkreutz R, Seibel A, Neri L, Storti E, Petrovic T; International Liaison Committee on Lung Ultrasound (ILC-LUS) for International Consensus Conference on Lung Ultrasound (ICC-LUS). International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012;38(4):577-91.)

We fully agree that B-lines are not always pathological. Lichtenstein et al. reported that 28% the healthy subjects in their sample exhibited comet-tail artifacts confined to the last intercostal space above the diaphragm.(22 Lichtenstein D, Mézière G, Biderman P, Gepner A, Barré O. The comet-tail artifact. An ultrasound sign of alveolar-interstitial syndrome. Am J Respir Crit Care Med. 1997;156(5):1640-6.) It should be noted that individuals in our study(33 Antonio AC, Teixeira C, Castro PS, Savi A, Maccari JG, Oliveira RP, et al. Behavior of lung ultrasound findings during spontaneous breathing trial. Rev Bras Ter Intensiva. 2017;29(3):279-86. Figure 1. Prevalence of B-pattern and consolidation (C-lines) in 12 zones before spontaneous breathing trial in all 57 individuals; p. 281. Table 2. B-predominance prior to spontaneous breathing trial and at the end of trial according to wearing groups. p. 283. Table 3. Performance of B-predominance as a screening test for wearing prediction; p. 283.) had in average six days on mechanical ventilation - and, thus, on supine position - before the lung ultrasound analysis. It is not surprising that more than half of our sample already exhibited B and C-lines in lower posterior lung regions, preceding spontaneous breathing trial (SBT), as shown on figure 1.(33 Antonio AC, Teixeira C, Castro PS, Savi A, Maccari JG, Oliveira RP, et al. Behavior of lung ultrasound findings during spontaneous breathing trial. Rev Bras Ter Intensiva. 2017;29(3):279-86. Figure 1. Prevalence of B-pattern and consolidation (C-lines) in 12 zones before spontaneous breathing trial in all 57 individuals; p. 281. Table 2. B-predominance prior to spontaneous breathing trial and at the end of trial according to wearing groups. p. 283. Table 3. Performance of B-predominance as a screening test for wearing prediction; p. 283.) Variables degrees of lung deaeration in dependent areas are likely to represent effects of gravity, perhaps worsened by fluid overload,(44 Besen BA, Gobatto AL, Melro LM, Maciel AT, Park M. Fluid and electrolyte overload in critically ill patients: An overview. World J Crit Care Med. 2015;4(2):116-29.) infectious or inflammatory injury.(55 Slutsky AS, Ranieri VM. Ventilator-induced lung injury. N Engl J Med. 2013;369(22):2126-36. Erratum in N Engl J Med. 2014 Apr 24;370(17):1668-9.)

We were not able to determine the clinical significance of the above findings, however the lack of variation during the spontaneous breathing trial led us to believe that anterior chest zones were sensitive enough to show physiological changes during weaning from mechanical ventilation. As the procedure took up to 120 minutes, the emergence of B-lines during such a short period suggested transudative mechanism, significantly demonstrated for subjects who failed SBT. More or less severe alveolar hydrostatic edema, or even exudative fluid underlying the so-called B-pattern might have played a role, particularly in critically ill subjects who failed to pass SBT. Still, this group showed a significant increase of B-predominance by the end of SBT (Table 2).(33 Antonio AC, Teixeira C, Castro PS, Savi A, Maccari JG, Oliveira RP, et al. Behavior of lung ultrasound findings during spontaneous breathing trial. Rev Bras Ter Intensiva. 2017;29(3):279-86. Figure 1. Prevalence of B-pattern and consolidation (C-lines) in 12 zones before spontaneous breathing trial in all 57 individuals; p. 281. Table 2. B-predominance prior to spontaneous breathing trial and at the end of trial according to wearing groups. p. 283. Table 3. Performance of B-predominance as a screening test for wearing prediction; p. 283.)

The performance of B-predominance according to weaning groups on predicting clinical endpoints was notably poor, as shown on table 3.(33 Antonio AC, Teixeira C, Castro PS, Savi A, Maccari JG, Oliveira RP, et al. Behavior of lung ultrasound findings during spontaneous breathing trial. Rev Bras Ter Intensiva. 2017;29(3):279-86. Figure 1. Prevalence of B-pattern and consolidation (C-lines) in 12 zones before spontaneous breathing trial in all 57 individuals; p. 281. Table 2. B-predominance prior to spontaneous breathing trial and at the end of trial according to wearing groups. p. 283. Table 3. Performance of B-predominance as a screening test for wearing prediction; p. 283.) Shortcomings of our investigation were also disclosed. We certainly cannot rule out the usefulness of echocardiography, and pleural and vein ultrasound examinations during weaning from mechanical ventilation and in many critical and emergency scenarios. However, we cannot completely agree that intensivists could accurately perform such assessments without consuming too much time. Although the Blue Protocol is based on six-region scans,(66 Lichtenstein DA, Mezière GA. Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest. 2008;134(1):117-25.) the authors designated A and B profiles based on anterior predominance of corresponding lines.

We completely agree that there is a compelling need to explore the full potential of lung ultrasound.

Ana Carolina Peçanha Antonio
Adult Intensive Care Unit, Hospital Moinhos de Vento - Porto Alegre (RS), Brazil.
Adult Intensive Care Unit, Hospital de Clínicas de Porto Alegre- Porto Alegre (RS), Brazil.
Cassiano Teixeira
Adult Intensive Care Unit, Hospital Moinhos de Vento - Porto Alegre (RS), Brazil.
Adult Intensive Care Unit, Hospital de Clínicas de Porto Alegre- Porto Alegre (RS), Brazil.

REFERÊNCIAS

  • 1
    Volpicelli G, Elbarbary M, Blaivas M, Lichtenstein DA, Mathis G, Kirkpatrick AW, Melniker L, Gargani L, Noble VE, Via G, Dean A, Tsung JW, Soldati G, Copetti R, Bouhemad B, Reissig A, Agricola E, Rouby JJ, Arbelot C, Liteplo A, Sargsyan A, Silva F, Hoppmann R, Breitkreutz R, Seibel A, Neri L, Storti E, Petrovic T; International Liaison Committee on Lung Ultrasound (ILC-LUS) for International Consensus Conference on Lung Ultrasound (ICC-LUS). International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012;38(4):577-91.
  • 2
    Lichtenstein D, Mézière G, Biderman P, Gepner A, Barré O. The comet-tail artifact. An ultrasound sign of alveolar-interstitial syndrome. Am J Respir Crit Care Med. 1997;156(5):1640-6.
  • 3
    Antonio AC, Teixeira C, Castro PS, Savi A, Maccari JG, Oliveira RP, et al. Behavior of lung ultrasound findings during spontaneous breathing trial. Rev Bras Ter Intensiva. 2017;29(3):279-86. Figure 1. Prevalence of B-pattern and consolidation (C-lines) in 12 zones before spontaneous breathing trial in all 57 individuals; p. 281. Table 2. B-predominance prior to spontaneous breathing trial and at the end of trial according to wearing groups. p. 283. Table 3. Performance of B-predominance as a screening test for wearing prediction; p. 283.
  • 4
    Besen BA, Gobatto AL, Melro LM, Maciel AT, Park M. Fluid and electrolyte overload in critically ill patients: An overview. World J Crit Care Med. 2015;4(2):116-29.
  • 5
    Slutsky AS, Ranieri VM. Ventilator-induced lung injury. N Engl J Med. 2013;369(22):2126-36. Erratum in N Engl J Med. 2014 Apr 24;370(17):1668-9.
  • 6
    Lichtenstein DA, Mezière GA. Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest. 2008;134(1):117-25.

Publication Dates

  • Publication in this collection
    Mar 2018
Associação de Medicina Intensiva Brasileira - AMIB Rua Arminda, 93 - Vila Olímpia, CEP 04545-100 - São Paulo - SP - Brasil, Tel.: (11) 5089-2642 - São Paulo - SP - Brazil
E-mail: rbti.artigos@amib.com.br