Acessibilidade / Reportar erro

Cough peak flow to predict extubation outcome: a systematic review and meta-analysis

Abstract

Objective:

This systematic review was designed to assess the usefulness of cough peak flow to predict the extubation outcome in subjects who passed a spontaneous breathing trial.

Methods:

The search covered the scientific databases MEDLINE, Lilacs, Ibecs, Cinahl, SciELO, Cochrane, Scopus, Web of Science and gray literature. The Quality Assessment of Diagnostic Accuracy Studies was used to assess the methodological quality and risk of study bias. The statistical heterogeneity of the likelihood (LR) and diagnostic odds ratios were evaluated using forest plots and Cochran’s Q statistic, and a crosshair summary Receiver Operating Characteristic plot using the multiple cutoffs model was calculated.

Results:

We initially retrieved 3,522 references from the databases; among these, 12 studies including 1,757 subjects were selected for the qualitative analysis. Many studies presented an unclear risk of bias in the “patient selection” and “flow and time” criteria. Among the 12 included studies, seven presented “high risk” and five “unclear risk” for the item “reference standard.” The diagnostic performance of the cough peak flow for the extubation outcome was low to moderate when we considered the results from all included studies, with a +LR of 1.360 (95%CI 1.240 - 1.530), -LR of 0.218 (95%CI 0.159 - 0.293) and a diagnostic odds ratio of 6.450 (95%CI 4.490 - 9.090). A subgroup analysis including only the studies with a cutoff between 55 and 65 L/minute showed a slightly better, although still moderate, performance.

Conclusion:

A cough peak flow assessment considering a cutoff between 55 and 65L/minute may be useful as a complementary measurement prior to extubation. Additional well-designed studies are necessary to identify the best method and equipment to record the cough peak flow as well as the best cutoff.

Keywords:
Airway extubation; Respiration; artificial; Weaning; Cough; Ventilator weaning; Respiratory therapy

RESUMO

Objetivo:

Avaliar a utilidade do pico de fluxo da tosse para predizer o desfecho da extubação em pacientes que obtiveram sucesso no teste de respiração espontânea.

Métodos:

A busca cobriu as bases de dados científicos MEDLINE, Lilacs, Ibecs, Cinahl, SciELO, Cochrane, Scopus, Web of Science e literatura cinzenta. Utilizaram-se os critérios Quality Assessment of Diagnostic Accuracy Studies para avaliar a qualidade da metodologia e o risco de viés dos estudos. A heterogeneidade estatística da razão de verossimilhança (LR) e razão de chance diagnóstica (RCD) do diagnóstico foram avaliadas com utilização de gráficos em floresta, teste Q de Cochran e um gráfico crosshair summary Receiver Operating Characteristic, utilizando um modelo com múltiplos pontos de corte.

Resultados:

Inicialmente obteve-se, nas bases de dados, um total de 3.522 referências; dentre estas, selecionaram-se para análise qualitativa 12 estudos que incluíram 1.757 participantes. Muitos estudos apresentavam um risco de viés incerto em termos da seleção de pacientes e do fluxo e tempo. Dentre os 12 estudos incluídos, sete tinham alto risco e cinco risco incerto para o item padrão de referência. O desempenho diagnóstico do pico de fluxo da tosse para o resultado da extubação foi baixo a moderado quando se consideram os resultados de todos os estudos incluídos, com +LR de 1,360 (IC95% 1,240 - 1,530), -LR de 0,218 (IC95% 0,159 - 0,293) e razão de chance diagnóstica de 6,450 (IC95% 4,490 - 9,090). Uma análise de subgrupos que incluiu somente estudos com valores de corte entre 55 e 65 L/minuto demonstrou desempenho ligeiramente melhor, porém ainda moderado.

Conclusão:

A avaliação do pico de fluxo da tosse, considerando valor de corte entre 55 e 65 L/minuto, pode ser útil como medida complementar antes da extubação. São necessários estudos com melhor delineamento para elucidar o melhor método e equipamento para registrar o pico de fluxo da tosse, assim como o melhor ponto de corte.

Descritores:
Extubação; Respiração artificial; Desmame; Tosse; Desmame da ventilação mecânica; Terapia respiratória

INTRODUCTION

Mechanical ventilation (MV) is essential for interventions in respiratory failure; however, the decision about ventilatory support interruption is paramount in the care of critically ill subjects. Increases in MV duration are associated with increased mortality and complications such as ventilator-associated pneumonia, ventilator-associated lung injury, atelectasis and pneumothorax, among others.(11 MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JE, Heffner JE, Hess D, Hubmayer RD, Scheinhorn DJ; American College of Chest Physicians; American Association for Respiratory Care; American College of Critical Care Medicine. Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest. 2001;120(6 Suppl):375S-95S.

2 Epstein SK. Weaning from ventilatory support. Curr Opin Crit Care. 2009;15(1):36-43.
-33 Esteban A, Anzueto A, Frutos F, Alia I, Brochard L, Stewart TE, Benito S, Epstein SK, Apezteguía C, Nightingale P, Arroliga AC, Tobin MJ; Mechanical Ventilation International Study Group. Characteristics and outcomes in adult patients receiving mechanical ventilation: a 28-day international study. JAMA. 2002;287(3):345-55.) Therefore, discontinuation of MV should be implemented as soon as possible. On the other hand, early extubation may lead to reintubation, which also leads to increased morbidity, increased length of hospital stay and mortality.(44 Frutos-Vivar F, Esteban A, Apezteguria C, González M, Arabi Y, Restrepo MI, et al. Outcome of reintubated patients after scheduled extubation. J Crit Care. 2011;26(5):502-9.,55 Coplin WM, Pierson DJ, Cooley KD, Newell DW, Rubenfeld GD. Implications of extubation delay in brain-injured patients meeting standard weaning criteria. Am J Respir Crit Care Med. 2000;161(5):1530-6.)

With the goal of avoiding complications resulting from both the unnecessary presence and precocious withdrawal of the endotracheal tube, a spontaneous breathing trial (SBT) is recommended in the current weaning guidelines to assess the patient’s ability to breathe spontaneously.(11 MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JE, Heffner JE, Hess D, Hubmayer RD, Scheinhorn DJ; American College of Chest Physicians; American Association for Respiratory Care; American College of Critical Care Medicine. Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest. 2001;120(6 Suppl):375S-95S.,66 Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, et al. Weaning from mechanical ventilation. Eur Respir J. 2007;29(5):1033-56.,77 Macintyre NR. Evidence-based assessments in the ventilator discontinuation process. Respir Care. 2012;57(10):1611-8.) It can be carried out using various techniques, such as low ventilatory pressure support, continuous positive airway pressure (CPAP), automatic tube compensation, or total removal of the mechanical ventilatory support by connecting a “T”-shaped piece in the endotracheal tube to an enriched oxygen source.(88 Burns KE, Soliman I, Adhikari NK, Zwein A, Wong JT, Gomes-Builes C, et al. Trials directly comparing alternative spontaneous breathing trial techniques: a systematic review and meta-analysis. Crit Care. 2017;21(1):127.) A trial is considered successful when the patient tolerates 30 minutes or more of either technique.(66 Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, et al. Weaning from mechanical ventilation. Eur Respir J. 2007;29(5):1033-56.,99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.) Although SBT has been proven to have high accuracy in predicting the weaning outcome, 12.4% to 21% of subjects who succeed in this test require reintubation within 48 to 72 hours.(66 Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, et al. Weaning from mechanical ventilation. Eur Respir J. 2007;29(5):1033-56.,77 Macintyre NR. Evidence-based assessments in the ventilator discontinuation process. Respir Care. 2012;57(10):1611-8.,99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.

10 Hayashi LY, Gazzotti MR, Vidotto MC, Jardim JR. Incidence, indication and complications of postoperative reintubation after elective intracranial surgery. Sao Paulo Med J. 2013;131(3):158-65.

11 11. Liu Y, Wei LQ, Li GQ, Lv FY, Wang H, Zhang YH, et al. A decision-tree model for predicting extubation outcome in elderly patients after a successful spontaneous breathing trial. Anesth Analg. 2010;111(5):1211-8.

12 Solsona JF, Díaz Y, Vázquez A, Pilar Gracia M, Zapatero A, Marrugat J. A pilot study of a new test to predict extubation failure. Crit Care. 2009;13(2):R56.

13 Navalesi P, Frigerio P, Moretti MP, Sommariva M, Vesconi S, Baiardi P, et al. Rate of reintubation in mechanically ventilated neurosurgical and neurologic subjects: evaluation of systematic approach to weaning and extubation. Crit Care Med. 2008;36(11):2986-92.
-1414 El Solh AA, Bhat A, Gunen H, Berbary E. Extubation failure in the elderly. Respir Med. 2004;98(7):661-8.) One of the main reasons reported for reintubation is ineffective coughing, resulting in secretion retention in the postextubation period, which cannot be predicted by the SBT.(1515 Rothaar RC, Epstein SK. Extubation failure: magnitude of the problem, impact on outcomes, and prevention. Curr Opin Crit Care. 2003;9(1):59-66.

16 Thille AW, Harrois A, Schortgen F, Brun-Buisson C, Brochard L. Outcomes of extubation failure in medical intensive care unit patients. Crit Care Med. 2011;39(12):2612-8.
-1717 Mokhlesi B, Tulaimat A, Gluckman TJ, Wang Y, Evans AT, Corbridge TC. Predicting extubation failure after successful completion of a spontaneous breathing trial. Respir Care. 2007;52(12):1710-7.)

Many studies have reported that cough strength assessment by the measurement of cough peak flow is very accurate in predicting the extubation outcome.(1818 Smina M, Salam A, Khamiees M, Gada P, Amoateng-Adjepong Y, Manthous CA. Cough peak flows and extubation outcomes. Chest. 2003;124(1):262-8.

19 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.

20 Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous CA. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334-9.
-2121 Gao XJ, Qin YZ. [A study of cough peak expiratory flow in predicting extubation outcome]. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2009;21(7):390-3. Chinese.) Moreover, this assessment is advocated as objective, easy to perform, inexpensive and reproducible.(2222 Jiang C, Esquinas A, Mina B. Evaluation of cough peak expiratory flow as a predictor of successful mechanical ventilation discontinuation: a narrative review of the literature. J Intensive Care. 2017;5:33.,2323 Duan J, Han X, Huang S, Bai L. Noninvasive ventilation for avoidance of reintubation in patients with various cough strength. Crit Care. 2016;20(1):316.) Despite these promising results, there are several methodological aspects to be considered in related studies, as well as differences regarding the accuracy, the best cutoff value to predict extubation success and how to obtain the measurement. Therefore, we decided to summarize the current evidence by conducting this systematic review and meta-analysis to assess the accuracy of cough peak flow measurement, the best cutoff point, and any technical issues regarding the procedure.

METHODS

The review methodology was defined prior to the start of data research. The protocol has been registered in the International Prospective Register of Systematic Reviews (registration number CRD42019143195). Changes were made in the initial protocol to include the possibility of further subgroup analyses. This addendum to the protocol aimed to enable the analysis of subgroups, including studies with similar characteristics, such as the use of rescue therapy, the cough stimulation method, equipment used, cutoff values, etc. However, subgroup analyses were only carried out in the presence of a sufficient number of studies with homogeneous characteristics. This systematic review was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist.(2424 Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264-9, W64.)

Search strategy

The searches of the databases were carried out on April 3rd, 2020 guided by two experienced librarians and two researchers. They covered the following databases and portals: MEDLINE® via PubMed®; BVS Portal, including Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs) and Índice Bibliográfico Español en Ciencias de la Salud (Ibecs) scientific databases; Cummulative Index to Nursing and Allied Health Literature(Cinahl); Scientific Electronic Library Online (SciELO); Cochrane; Scopus; Web of Science; Embase®; and gray literature. Additionally, we searched a clinical trials registry (http://clinicaltrials.gov) for unpublished and ongoing studies.

The search strategy used the following keywords: (“artificial respiration” or “ventilation mechanical” or “intubation” or “spontaneous breathing trial” or “critical care” or “intensive care”) and (cough or “peak expiratory flow rate”) and (“airway extubation” or weaning or “ventilator weaning” or extubation). For the Embase® database, the search strategy was (“artificial ventilation” or intubation or “intensive care”) and coughing or “peak expiratory flow”) and weaning or “ventilator weaning” or “extubation failure.”

This research was designed to obtain the highest possible sensitivity, while its specificity was ensured by manual reviews of the retrieved results. FG and NA independently examined the titles and abstracts resulting from the electronic search to exclude obviously irrelevant articles. After this stage, the full texts of the other studies were evaluated. The two reviewers discussed the texts to reach a consensus when there was a disagreement.

Inclusion and exclusion criteria

The inclusion criteria were as follows: (1) type of study: prospective or retrospective peer-reviewed studies in English, Portuguese or Spanish; (2) population: subjects older than 18 years under MV for more than 24 hours who were successful in the SBT and considered able to be extubated; (3) index test/assessment: measurement of cough peak flow prior to the extubation process; and (4) predefined results: the expected outcome of the cough peak flow assessment’s ability to predict extubation success or failure. The following were excluded: abstracts, letters, editorials, expert opinions, reviews and case reports; studies with tracheotomized subjects; and studies with subjects extubated for clinical comfort.

Data extraction

Two reviewers extracted the data independently using a predefined data extraction form. The data extracted included the first author’s name, year of publication, study design, cough assessment method (voluntary or involuntary), instrument used for measurement, use of rescue therapy (yes or no, device), sample size (n), extubation failure or success (n), sensitivity and specificity, cutoff, area under the Receiver Operating Characteristic (ROC) curve (AUC), positive and negative predictive value, relative risk, odds ratio and positive and negative likelihood ratios. Articles by the same author were carefully examined to avoid duplication of the included studies, and any disagreement was resolved by consensus.

Quality assessment and publication bias

The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2)(2525 Whiting PF, Rutjes AW, Westwood ME, Mallet S, Deeks JJ, Reitsma JB, Leeflang MM, Sterne JA, Bossuyt PM; QUADAS-2 Group. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. An Intern Med. 2011;155(8):529-36.) was used to assess the methodological quality and risk of study bias. This tool is structured in four domains that present the main sources of bias, including patient selection, index testing, reference standard and flow and time. Each domain is assessed for bias risk and, except for the flow and time domains, for test applicability.

Statistical analysis

Statistical analysis was performed by ASF using R Project version 3.6.2(2626 R Core Team. R: A language and environment for statistical. Version 2.6.2 (2008-02-08). Vienna, Austria: R Foundation for Statistical Computing; c1999-2003.) and the packages diagmeta(2727 Rücker G, Steinhauser S, Kolampally S, Schwarzer G. Meta-analysis of diagnostic accuracy studies with several cutpoints. [cited 2020 May 15]. Available from: https://github.com/guido-s/diagmeta
https://github.com/guido-s/diagmeta...
) and mada,(2828 Doebler P. MADA package: meta-analysis of diagnostic accuracy. [cited 2020 May 15]. Available from https://r-forge.r-project.org/projects/mada
https://r-forge.r-project.org/projects/m...
) as recommended.(2929 Wang J, Leeflang M. Recommended software/packages for meta-analysis of diagnostic accuracy. J Lab Precis Med. 2019;4:22.)

Positive and negative likelihood ratios (+LR and -LR, respectively; the magnitude by which the probability of extubating a given patient is modified by the results of the cough peak flow test) and the diagnostic odds ratio (DOR; the ratio of the odds of a positive result in a patient with successful extubation compared with a patient with unsuccessful extubation) were calculated for each study. Pooling of the indices was performed with the bivariate model of Zwindermann & Bossuyt.(3030 Zwinderman AH, Bossuyt PM. We should not pool diagnostic likelihood ratios in systematic reviews. Stat Med. 2008;27(5):687-97.) Confidence intervals (95%CIs) were calculated using Wilson’s method. The statistical heterogeneity of likelihood and DORs were evaluated using forest plots and Cochran’s Q statistic, in which each study was weighted by the use of an inverse variance model; significant heterogeneity was detected when p < 0.10 due to the number of studies included.(3131 Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557-60.) To quantify the extent of heterogeneity, we used Higgins’s I2 statistic to measure the percentage of variability among summary indices that was caused by heterogeneity rather than chance (0% to 25%, may not be important; 25% to 50%, may represent low heterogeneity; 50% to 75%, may represent moderate heterogeneity; 75% to 100%, may represent high heterogeneity).(3131 Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557-60.)

The paired sensitivity and specificity values of each study are presented on a crosshair summary ROC (sROC) plot using the multiple cutoff model.(3232 Steinhauser S, Schumacher M, Rücker G. Modelling multiple thresholds in meta-analysis of diagnostic test accuracy studies. BMC Med Res Methodol. 2016;16(1):97.) A smoothed curve was then fitted across the studies to represent the relationship between the true positive and false positive (1-specificity) fractions of each study, from which the area under the ROC (AUROC) curve was calculated. To investigate whether variations in the diagnostic threshold affected the shape of the sROC curve, the threshold effect was tested using the regression equation log (DOR) = a + b·S, where S is a measure of the diagnostic threshold (null hypothesis: b = 0). A subgroup analysis was conducted with studies that reported a cutoff value in the range of 55 to 65L/min. Publication bias was assessed by funnel plots for the DOR using Deeks’ funnel plot asymmetry test. Significant asymmetry (p < 0.10) indicates the presence of publication bias.(3333 Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005;58(9):882-93.)

RESULTS

Literature search results

We initially identified 3,522 references in the databases, and after the removal of 818 duplicates, we obtained 2,704 studies. Among these, we discarded 2,654 articles after reading the titles and abstracts. We examined the full texts of 50 articles and excluded 38 that did not meet the inclusion criteria. Finally, 12 articles were selected for inclusion in this review (Figure 1).

Characteristics of the studies

The main individual characteristics of the studies are summarized in table 1. Among the 12 included studies,(99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.,1818 Smina M, Salam A, Khamiees M, Gada P, Amoateng-Adjepong Y, Manthous CA. Cough peak flows and extubation outcomes. Chest. 2003;124(1):262-8.

19 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.
-2020 Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous CA. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334-9.,2323 Duan J, Han X, Huang S, Bai L. Noninvasive ventilation for avoidance of reintubation in patients with various cough strength. Crit Care. 2016;20(1):316.,3434 Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.

35 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.

36 Duan J, Zhou L, Xiao M, Liu J, Yang X. Semiquantitative cough strength score for predicting reintubation after planned extubation. Am J Crit Care. 2015;24(6):e86-90.

37 Kutchak FM, Debesaitys AM, Rieder MM, Meneguzzi C, Skueresky AS, Forgiarini Junior LA, et al. Reflex cough as predictor of successful extubation in neurological subjects. J Bras Pneumol. 2015;41(4):358-64.

38 Bai L, Duan J. Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable. Respir Care. 2017;62(5):566-71.

39 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.
-4040 Xiao M, Duan J. Weaning attempts, cough strength and albumin are independent risk factors of reintubation in medical patients. Clin Respir J. 2018;12(3):1240-6.) two had their results divided for analysis.(3535 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.,3838 Bai L, Duan J. Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable. Respir Care. 2017;62(5):566-71.) Thus, 14 sets of results are presented in table 2, with one study published each year in 2003, 2004, 2009, 2010, 2013, 2014, 2016 and 2018, corresponding to 66%; two (17%) studies published in 2015; and two (17%) studies published in 2017. The total sample size from the included studies was 1,757 (range 88 to 356) participants, of whom 135 were classified as neurological and 125 were classified as burned. Cough assessment was performed voluntarily in nine articles and involuntarily in two articles, and one article compared the two forms. Four articles used noninvasive ventilation (NIV) as rescue therapy, and one of those also used mechanically assisted cough. Two studies assessed the cough peak flow with a mechanical ventilator, and one of those compared the evaluation of the cough peak flow between a spirometer and ventilator. The postextubation observation period was up to 72 hours in seven studies, up to 48 hours in four studies and up to hospital discharge in one study. In the studies in which there was no contingency table, we e-mailed the authors to ask for data to construct 2 x 2 tables.

Figure 1
Selection of studies included in this meta-analysis.

Cinahl - Cumulative Index of Nursing and Allied Health Literature; SciELO - Scientific Electronic Library Online; BVS - Biblioteca Virtual em Saúde.


The ROC curve was calculated in seven studies, while the cutoff point was defined “a priori” in five studies. The specificity and sensitivity values ranged from 55.1 to 87 and from 69 to 85, respectively. The area under the ROC curve ranged from 0.61 to 0.83, and the averaged cutoff value for the cough peak flow was 59.3 ± 9.9L/minute (range 35 to 80L/minute). Ten (71%) results from nine studies used cutoff values in the range of 56 to 62.4L/minute. The total number of successful cases was 1,677 (84%), with an average cough peak flow value of 83.6 ± 17.9L/minute (range 63.6 to 125.8L/minute). The total number of failures was 321 (16%), with an average cough peak flow value of 55.5 ± 11.1L/minute (range 36.3 to 75.8L/minute). The details of all included studies are shown in tables 1 and 2.

Quality assessment of the included studies

Most studies presented a low to unclear risk of bias in the overall analysis, except for the item “reference standard.” Among the 12 included studies, seven presented a “high risk” and five an “unclear risk” due to a lack of objective clinical criteria for reintubation and the nonexclusion of subjects who were reintubated for laryngospasm. The use of NIV as rescue therapy was observed in four studies and was classified as “unclear risk” for bias in the item “flow and time”. Three studies including reintubated subjects were also assigned as having “unclear risk” in the item “flow and time.” Three studies reported that the subjects were ready to wean but did not describe specific criteria, so we assigned them to the “unclear risk” classification in the item “patient selection” (Figures 2 and 3).

Quantitative data synthesis

Regarding the confusion matrix analysis, 10 (71%) results reported sensitivity and specificity values alongside the area under the ROC curve. Four (29%) results reported positive and negative predictive values. Five (36%) results reported positive likelihood values, and four (29%) reported negative likelihood values. Five (36%) studies also reported the relative risk, whereas only three (21%) reported the odds ratio. The pooled summary probabilities (Figures 4 and 5) showed that the diagnostic performance of the cough peak flow for extubation was low to moderate, with a +LR of 1.360 (95%CI 1.240 - 1.530), -LR of 0.218 (95%CI 0.159 - 0.293) and DOR of 6.450 (95%CI 4.490 - 9.090). No evidence of heterogeneity was observed for +LR (Cochran’s Q = 9.426, p = 0.399, I2 = 4.5%), -LR (Cochran’s Q = 7.493, p = 0.586, I2 = 0%) or DOR (Cochran’s Q = 7.889, p = 0.545, I2 = 0%).

Table 1
Characteristics of the included studies
Figure 2
Assessment of the risk of bias of the included studies (Quality Assessment of Diagnostic Accuracy Studies 2 - QUADAS 2).
Table 2
Predictive power of the peak cough flow of the included studies

The sROC curve yielded a maximum sensitivity of 0.767 (95%CI 0.353 - 0.967) and a specificity of 0.536 (95%CI 0.158 - 0.882) and an area under the curve of 0.696 (given sensitivity: 95%CI 0.088 to-0.015; given specificity: 95%CI 0.441 to 0.980), consistent with the moderate diagnostic accuracy of the cough peak flow for extubation (Figure 5, left panel). We observed no evidence of a threshold effect (b = -0.007, p = 0.668). Figure 6 shows Deeks’ funnel plot asymmetry test for publication bias. We observed a significant asymmetry (p = 0.043), indicating the presence of publication bias across studies.

Subgroup analysis

Six (43%) studies reported a cutoff value in the range of 55 to 65L/minute. The pooled summary probabilities showed that the diagnostic performance of the cough peak flow for extubation was slightly higher than the overall quantitative synthesis, with a +LR of 1.390 (95%CI 1.270 - 1.540), -LR of 0.176 (95%CI 0.109 - 0.267), and DOR of 8.400 (95%CI 4.740 - 13.600). No evidence of heterogeneity was observed for +LR (Cochran’s Q = 4.417, p = 0.491, I2 = 0%), -LR (Cochran’s Q = 4.339, p = 0.501, I2 = 0%), or DOR (Cochran’s Q = 4.827, p = 0.437, I2 = 0%). Due to the limited number of studies, no subgroup analysis was conducted for the sROC curve. Likewise, we observed no evidence of a threshold effect (b = -0.155, p = 0.182).

DISCUSSION

The current recommendations for extubation readiness testing are focused on SBT performance; however, it is known that this trial cannot assess individuals’ capacity to protect their airways, which is directly related to the extubation outcome. Therefore, considering that extubation failure is associated with increased mortality and MV stay among ICU subjects,(11 MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JE, Heffner JE, Hess D, Hubmayer RD, Scheinhorn DJ; American College of Chest Physicians; American Association for Respiratory Care; American College of Critical Care Medicine. Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest. 2001;120(6 Suppl):375S-95S.,1616 Thille AW, Harrois A, Schortgen F, Brun-Buisson C, Brochard L. Outcomes of extubation failure in medical intensive care unit patients. Crit Care Med. 2011;39(12):2612-8.) a number of authors have assessed the cough strength in subjects who succeed in an SBT, with the goal of predicting the extubation outcome.

Figure 3
Group bar charts showing the risk of bias and applicability concerns of the twelve included records using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).
Figure 4
Pooled summary of positive and negative likelihood ratios of the included studies.

The evaluation of cough peak flow is an objective method to predict successful extubation, which can be carried out voluntarily or involuntarily. Most of the studies in this review evaluated voluntary coughing, which depends on the patient’s motivation, effective coordination and the preservation of respiratory neuromuscular activity. Two studies evaluated the subjects in an involuntary way - i.e., one triggered by the cough reflex.(3434 Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.,3737 Kutchak FM, Debesaitys AM, Rieder MM, Meneguzzi C, Skueresky AS, Forgiarini Junior LA, et al. Reflex cough as predictor of successful extubation in neurological subjects. J Bras Pneumol. 2015;41(4):358-64.) Su et al. considered this method more natural, being similar to the physiological cough and having the advantage of covering uncooperative subjects who do not want or are unable to produce a cough voluntarily.(3434 Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.) Duan et al., in a study with 115 subjects (5 of whom were noncooperative), compared voluntary and involuntary cough assessments (by instilling 2mL of saline), concluding that voluntary coughing is not invasive and has a greater capacity to predict extubation failure than involuntary coughing in cooperative subjects.(3535 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.) As the cough reflex response may be directly proportional to the stimulation, it is not known whether a stronger stimulus, such as mechanical stimulation with a catheter or instilling a higher saline volume, would produce better results. Nevertheless, the instillation of saline solution could be uncomfortable and could lead to transitory desaturation. Thus, voluntary measures would be more suitable for cooperative individuals, whereas involuntary stimulation could be reserved for noncooperative subjects. Another alternative is using voluntary testing first in cooperative subjects. If the cough peak flow is below the success threshold, an effective involuntary stimulation would be applied to discard false-negative results due to the low motivation of the subjects.

Figure 5
Diagnostic accuracy of the cough peak flow for the extubation outcome: pooled odds ratio and summary Receiver Operating Characteristic curve.

ROC - Receiver Operating Characteristic; 95%CI - 95% confidence interval; AUROC - under Receiver Operating Characteristic.


Most of the studies used an external spirometer to record the cough peak flow. However, two studies used mechanical ventilator displays. Bai et al. concluded that both methods had good predictive accuracy for reintubation (AUC = 0.79 for the spirometer versus AUC = 0.83 for the ventilator, p = 0.26).(3838 Bai L, Duan J. Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable. Respir Care. 2017;62(5):566-71.) Similarly, Gobert et al. used a flow meter built into a ventilator, showing good predictive capacity (AUC = 0.61) and highlighting the advantage of not requiring additional costs to purchase a device or having to disconnect the patient.(3939 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.) Although a measurement using the mechanical ventilator is more practical, some aspects must be taken into account, such as how much the ventilator circuit resistance reduces the cough peak flow (perhaps determining a lower cutoff), what frequency response and sampling frequency are needed in the ventilator acquisition system and what the most appropriate ventilatory parameters are necessary to perform the measurement. Other technical aspects can also affect the reliability of the cough peak flow measurements, regardless of whether they are made with a ventilator or with an external device. The European Respiratory Society (ERS)(4141 Laveneziana P, Albuquerque A, Aliverti A, Babb T, Barreiro E, Dres M, et al. ERS statement on respiratory muscle testing at rest and during exercise. Eur Respir J. 2019;53(6):1801214.) carried out a complete—although not specifically designed for the target population of our study—update on respiratory muscle tests since its last recommendations in 2002, advising on the importance of the standardization of peak expiratory flow measurements. Aspects such as the number of maneuvers, patient position and possible discrepancies between different measurement instruments were pointed to as important contributors to different results across the studies. The authors of the articles selected for this review used different measurement instruments, and generally, they did not describe how the maneuvers were performed. The position of the subjects, level of consciousness, endotracheal tube size, number of measurements and the interval(s) between them, acceptability criteria for the measurements, and how the researchers performed the verbal stimulation are examples of data not reported in most studies.

Figure 6
Deeks’ funnel plot asymmetry test for publication bias across studies.

SSE - sample size-effectiveness. Significant asymmetry (p = 0.043) indicates the presence of publication bias.


Among the studies included in this review, Beuret et al. presented the lowest cough peak flow cutoff value at 35L/minute, which may be considered an outlier compared to the other values.(1919 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.) This difference could be attributed to the abovementioned issues and the lack of information about how long the subjects remained in an SBT, since a longer time might have predisposed subjects to fatigue prior to the assessment, resulting in lower cough peak flow values. Moreover, the use of NIV as rescue therapy may have postponed the reintubation of subjects with a low cough peak flow, causing them to be reintubated beyond the 48 hours that determined extubation failure in their study. At the other extreme, the cutoff value of 80L/min found in the study of Kutchak et al. may also be an outlier compared to the values of the other studies in this review.(3737 Kutchak FM, Debesaitys AM, Rieder MM, Meneguzzi C, Skueresky AS, Forgiarini Junior LA, et al. Reflex cough as predictor of successful extubation in neurological subjects. J Bras Pneumol. 2015;41(4):358-64.) Some factors that may have contributed to this result include subjects who were younger than in the other studies and mostly male and the use of the Mini Wright flowmeter, which may have resulted in overreading and measurement bias.(4242 Jackson AC. Accuracy, reproducibility, and variability of portable peak flowmeters. Chest. 1995;107(3):648-51.,4343 Miller MR, Dickinson SA, Hitchings DJ. The accuracy of portable peak flow meters. Thorax. 1992;47(11):904-9.)

When we analyzed the risk of bias, the “reference standard” criterion presented “high risk” or “unclear risk” in most studies. For this review, the reference standard was considered the outcome of extubation—that is, as essential to calculating the predictive power of cough peak flow. Unfortunately, seven(99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.,1919 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.,2020 Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous CA. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334-9.,3434 Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.,3636 Duan J, Zhou L, Xiao M, Liu J, Yang X. Semiquantitative cough strength score for predicting reintubation after planned extubation. Am J Crit Care. 2015;24(6):e86-90.,3737 Kutchak FM, Debesaitys AM, Rieder MM, Meneguzzi C, Skueresky AS, Forgiarini Junior LA, et al. Reflex cough as predictor of successful extubation in neurological subjects. J Bras Pneumol. 2015;41(4):358-64.,3939 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.) of the 12 included studies did not report the criteria that guided decision-making regarding reintubation. Moreover, the authors did not exclude reintubations due to laryngospasm and laryngeal edema, which are relatively common causes of extubation failure and are not related to the subjects’ ability to eliminate secretions. Another possible source of bias was the difference in the temporal criterion to define extubation failure. Some authors considered reintubation within 48 hours, while others considered 72 hours after extubation as the failure criterion.

The inclusion of subjects who had already been extubated was scored as “unclear risk” in the “flow and time” criterion,(99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.,1818 Smina M, Salam A, Khamiees M, Gada P, Amoateng-Adjepong Y, Manthous CA. Cough peak flows and extubation outcomes. Chest. 2003;124(1):262-8.,3535 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.) since reintubation is associated with a longer duration of intensive care and hospital stay, an increased incidence of ventilator-associated pneumonia, laryngeal edema and increased mortality.(4444 Menon N, Joffe AM, Deem S, Yanez ND, Grabinsky A, Dagal AH, et al. Occurrence and complications of tracheal reintubation in critically ill adults. Respir Care. 2012;57(10):1555-63.,4545 Maggiore SM, Battilana M, Serano L, Petrini F. Ventilatory support after extubation in critically ill patients. Lancet Respir Med. 2018;6(12):948-62.) Although the evidence is scarce regarding the use of NIV to prevent reintubation,(4545 Maggiore SM, Battilana M, Serano L, Petrini F. Ventilatory support after extubation in critically ill patients. Lancet Respir Med. 2018;6(12):948-62.) four studies(1919 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.,2323 Duan J, Han X, Huang S, Bai L. Noninvasive ventilation for avoidance of reintubation in patients with various cough strength. Crit Care. 2016;20(1):316.,3535 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.,3939 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.) in this review have included this procedure as rescue therapy. Even when NIV is not effective at preventing reintubation, its use may delay it. Therefore, as the “reference standard” uses a 48- or 72-hour time criterion, we considered that the use of NIV during the postextubation period represents an “unclear” risk of bias in the “flow and time” criterion. In three studies,(1919 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.,3636 Duan J, Zhou L, Xiao M, Liu J, Yang X. Semiquantitative cough strength score for predicting reintubation after planned extubation. Am J Crit Care. 2015;24(6):e86-90.,3737 Kutchak FM, Debesaitys AM, Rieder MM, Meneguzzi C, Skueresky AS, Forgiarini Junior LA, et al. Reflex cough as predictor of successful extubation in neurological subjects. J Bras Pneumol. 2015;41(4):358-64.) “unclear risk” was given in the “patient selection” criterion. These studies did not sufficiently describe the parameters for considering subjects ready to wean, the criteria for interrupting the SBT or that subjects had to pass the SBT to be included. Studies that did not sufficiently describe how the cough peak flow measurement was performed or that established the cutoff a priori (and not from the ROC curve) also received an “unclear” or “high risk” rating in the “index test” criterion.

Despite the methodological limitations, different measurement instruments and ways in which the cough peak flow was measured, we observed that nine of the 12 studies in this review had cough peak flow cutoff values between 56 and 62.4L/minute, presenting high sensitivity and specificity to predict success in planned extubation.(99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.,1818 Smina M, Salam A, Khamiees M, Gada P, Amoateng-Adjepong Y, Manthous CA. Cough peak flows and extubation outcomes. Chest. 2003;124(1):262-8.,2020 Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous CA. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334-9.,3434 Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.

35 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.
-3636 Duan J, Zhou L, Xiao M, Liu J, Yang X. Semiquantitative cough strength score for predicting reintubation after planned extubation. Am J Crit Care. 2015;24(6):e86-90.,3838 Bai L, Duan J. Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable. Respir Care. 2017;62(5):566-71.

39 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.
-4040 Xiao M, Duan J. Weaning attempts, cough strength and albumin are independent risk factors of reintubation in medical patients. Clin Respir J. 2018;12(3):1240-6.) Among these nine studies, five calculated the cutoff from the ROC curve.(1818 Smina M, Salam A, Khamiees M, Gada P, Amoateng-Adjepong Y, Manthous CA. Cough peak flows and extubation outcomes. Chest. 2003;124(1):262-8.,3434 Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.

35 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.
-3636 Duan J, Zhou L, Xiao M, Liu J, Yang X. Semiquantitative cough strength score for predicting reintubation after planned extubation. Am J Crit Care. 2015;24(6):e86-90.,3838 Bai L, Duan J. Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable. Respir Care. 2017;62(5):566-71.) Because these results strongly suggest that the best cutoff to predict the outcome of extubation is approximately 60L/minute, some authors adopted this threshold when determining the cutoff a priori in their studies.(99 Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.,2020 Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous CA. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334-9.,3939 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.,4040 Xiao M, Duan J. Weaning attempts, cough strength and albumin are independent risk factors of reintubation in medical patients. Clin Respir J. 2018;12(3):1240-6.) No study considered the factors of age, sex or endotracheal tube size (endotracheal tubes with smaller diameters may determine lower cough peak flow results for the same individuals), which might be confounders for determining the best cutoff. Age and sex are directly related to the predicted peak expiratory flow. Therefore, it is likely that women and older people may have a cough peak flow that is lower but within a normal range. Moreover, table 1 shows that in practically all included studies, the mean age was higher among patients who failed extubation. Considering that older individuals have a greater risk of failure and lower predicted peak flow values, collinearity may have occurred in predicting the extubation outcome. Thus, future studies should control for the factors age, sex and endotracheal tube diameter to assess the peak cough flow’s predictive power concerning the extubation outcome.

When we analyzed the subgroup of studies with cutoff values between 55 and 65L/minute, the diagnostic performance of the cough peak flow was slightly higher than the overall quantitative synthesis, reinforcing the current assumption that the best cutoff is approximately 60L/minute.

The rationale of cough peak flow as a predictor of extubation outcome in subjects who succeed in an SBT is based on secretion retention during the postextubation period due to cough ineffectiveness. Therefore, measures should be taken to optimize airway clearance and to prevent reintubation in subjects who present with a low cough peak flow. Some evidence reinforces this premise, such as a study from Duan et al., who divided their sample of 356 individuals who succeeded in an SBT into subjects eligible for treatment with NIV or conventional oxygen therapy (control group).(2323 Duan J, Han X, Huang S, Bai L. Noninvasive ventilation for avoidance of reintubation in patients with various cough strength. Crit Care. 2016;20(1):316.) Their results showed that for subjects with a cough peak flow ≤ 70L/minute, NIV reduced reintubation compared to the control group (9% versus 35% postextubation up to 72 hours, p < 0.01). Subjects with cough peak flow > 70L/minute did not benefit from NIV, which strengthens the hypothesis that NIV as rescue therapy may have been a source of bias in another three cough peak flow studies included in this review.(1919 Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.,3535 Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.,3939 Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.)

As limitations of this review, we found that the included studies used different methods, rescue therapies, extubation failure criteria, populations, and devices to perform the measurements. These differences, the lack of relevant information, and some other methodological limitations of the included studies make it difficult to devise recommendations for recording the cough peak flow and the best cutoff point associated with the extubation outcome. Moreover, along with a possible presence of publication bias, all of these abovementioned issues may have contributed to the asymmetry observed in the funnel plot analysis (Figure 6)(4646 Song F, Khan KS, Dinnes J, Sutton AJ. Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy. Int J Epidemiol. 2002;31(1):88-95.) and the moderate diagnostic performance found in the statistical analysis.

CONCLUSION

The cough peak flow recording is promising for improving approaches to subjects during the process of mechanical ventilation withdrawal. The studies included in this review make it very clear that reduced cough peak flow values are associated with extubation failure. The cutoff of approximately 60L/minute seems to have the best accuracy. However, recommendations about how to perform the measurement are necessary so that well-designed studies using standardized protocols can in the future determine the best cutoff associated with the extubation outcome.

ACKNOWLEDGMENTS

Supported by:Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ) and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) - Finance Code 001.

REFERÊNCIAS

  • 1
    MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JE, Heffner JE, Hess D, Hubmayer RD, Scheinhorn DJ; American College of Chest Physicians; American Association for Respiratory Care; American College of Critical Care Medicine. Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest. 2001;120(6 Suppl):375S-95S.
  • 2
    Epstein SK. Weaning from ventilatory support. Curr Opin Crit Care. 2009;15(1):36-43.
  • 3
    Esteban A, Anzueto A, Frutos F, Alia I, Brochard L, Stewart TE, Benito S, Epstein SK, Apezteguía C, Nightingale P, Arroliga AC, Tobin MJ; Mechanical Ventilation International Study Group. Characteristics and outcomes in adult patients receiving mechanical ventilation: a 28-day international study. JAMA. 2002;287(3):345-55.
  • 4
    Frutos-Vivar F, Esteban A, Apezteguria C, González M, Arabi Y, Restrepo MI, et al. Outcome of reintubated patients after scheduled extubation. J Crit Care. 2011;26(5):502-9.
  • 5
    Coplin WM, Pierson DJ, Cooley KD, Newell DW, Rubenfeld GD. Implications of extubation delay in brain-injured patients meeting standard weaning criteria. Am J Respir Crit Care Med. 2000;161(5):1530-6.
  • 6
    Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, et al. Weaning from mechanical ventilation. Eur Respir J. 2007;29(5):1033-56.
  • 7
    Macintyre NR. Evidence-based assessments in the ventilator discontinuation process. Respir Care. 2012;57(10):1611-8.
  • 8
    Burns KE, Soliman I, Adhikari NK, Zwein A, Wong JT, Gomes-Builes C, et al. Trials directly comparing alternative spontaneous breathing trial techniques: a systematic review and meta-analysis. Crit Care. 2017;21(1):127.
  • 9
    Smailes ST, McVicar AJ, Martin R. Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial. Burns. 2013;39(2):236-42.
  • 10
    Hayashi LY, Gazzotti MR, Vidotto MC, Jardim JR. Incidence, indication and complications of postoperative reintubation after elective intracranial surgery. Sao Paulo Med J. 2013;131(3):158-65.
  • 11
    11 Liu Y, Wei LQ, Li GQ, Lv FY, Wang H, Zhang YH, et al. A decision-tree model for predicting extubation outcome in elderly patients after a successful spontaneous breathing trial. Anesth Analg. 2010;111(5):1211-8.
  • 12
    Solsona JF, Díaz Y, Vázquez A, Pilar Gracia M, Zapatero A, Marrugat J. A pilot study of a new test to predict extubation failure. Crit Care. 2009;13(2):R56.
  • 13
    Navalesi P, Frigerio P, Moretti MP, Sommariva M, Vesconi S, Baiardi P, et al. Rate of reintubation in mechanically ventilated neurosurgical and neurologic subjects: evaluation of systematic approach to weaning and extubation. Crit Care Med. 2008;36(11):2986-92.
  • 14
    El Solh AA, Bhat A, Gunen H, Berbary E. Extubation failure in the elderly. Respir Med. 2004;98(7):661-8.
  • 15
    Rothaar RC, Epstein SK. Extubation failure: magnitude of the problem, impact on outcomes, and prevention. Curr Opin Crit Care. 2003;9(1):59-66.
  • 16
    Thille AW, Harrois A, Schortgen F, Brun-Buisson C, Brochard L. Outcomes of extubation failure in medical intensive care unit patients. Crit Care Med. 2011;39(12):2612-8.
  • 17
    Mokhlesi B, Tulaimat A, Gluckman TJ, Wang Y, Evans AT, Corbridge TC. Predicting extubation failure after successful completion of a spontaneous breathing trial. Respir Care. 2007;52(12):1710-7.
  • 18
    Smina M, Salam A, Khamiees M, Gada P, Amoateng-Adjepong Y, Manthous CA. Cough peak flows and extubation outcomes. Chest. 2003;124(1):262-8.
  • 19
    Beuret P, Roux C, Auclair A, Nourdine K, Kaaki M, Carton M. Interest of an objective evaluation of cough during weaning from mechanical ventilation. Intensive Care Med. 2009;35(6):1090-3.
  • 20
    Salam A, Tilluckdharry L, Amoateng-Adjepong Y, Manthous CA. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334-9.
  • 21
    Gao XJ, Qin YZ. [A study of cough peak expiratory flow in predicting extubation outcome]. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2009;21(7):390-3. Chinese.
  • 22
    Jiang C, Esquinas A, Mina B. Evaluation of cough peak expiratory flow as a predictor of successful mechanical ventilation discontinuation: a narrative review of the literature. J Intensive Care. 2017;5:33.
  • 23
    Duan J, Han X, Huang S, Bai L. Noninvasive ventilation for avoidance of reintubation in patients with various cough strength. Crit Care. 2016;20(1):316.
  • 24
    Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264-9, W64.
  • 25
    Whiting PF, Rutjes AW, Westwood ME, Mallet S, Deeks JJ, Reitsma JB, Leeflang MM, Sterne JA, Bossuyt PM; QUADAS-2 Group. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. An Intern Med. 2011;155(8):529-36.
  • 26
    R Core Team. R: A language and environment for statistical. Version 2.6.2 (2008-02-08). Vienna, Austria: R Foundation for Statistical Computing; c1999-2003.
  • 27
    Rücker G, Steinhauser S, Kolampally S, Schwarzer G. Meta-analysis of diagnostic accuracy studies with several cutpoints. [cited 2020 May 15]. Available from: https://github.com/guido-s/diagmeta
    » https://github.com/guido-s/diagmeta
  • 28
    Doebler P. MADA package: meta-analysis of diagnostic accuracy. [cited 2020 May 15]. Available from https://r-forge.r-project.org/projects/mada
    » https://r-forge.r-project.org/projects/mada
  • 29
    Wang J, Leeflang M. Recommended software/packages for meta-analysis of diagnostic accuracy. J Lab Precis Med. 2019;4:22.
  • 30
    Zwinderman AH, Bossuyt PM. We should not pool diagnostic likelihood ratios in systematic reviews. Stat Med. 2008;27(5):687-97.
  • 31
    Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557-60.
  • 32
    Steinhauser S, Schumacher M, Rücker G. Modelling multiple thresholds in meta-analysis of diagnostic test accuracy studies. BMC Med Res Methodol. 2016;16(1):97.
  • 33
    Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005;58(9):882-93.
  • 34
    Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest. 2010;137(4):777-82.
  • 35
    Duan J, Liu J, Xiao M, Yang X, Wu J, Zhou L. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects. Respir Care. 2014;59(11):1643-51.
  • 36
    Duan J, Zhou L, Xiao M, Liu J, Yang X. Semiquantitative cough strength score for predicting reintubation after planned extubation. Am J Crit Care. 2015;24(6):e86-90.
  • 37
    Kutchak FM, Debesaitys AM, Rieder MM, Meneguzzi C, Skueresky AS, Forgiarini Junior LA, et al. Reflex cough as predictor of successful extubation in neurological subjects. J Bras Pneumol. 2015;41(4):358-64.
  • 38
    Bai L, Duan J. Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable. Respir Care. 2017;62(5):566-71.
  • 39
    Gobert F, Yonis H, Tapponnier R, Fernandez R, Labaune MA, Burle JF, et al. Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter. Respir Care. 2017;62(12):1505-19.
  • 40
    Xiao M, Duan J. Weaning attempts, cough strength and albumin are independent risk factors of reintubation in medical patients. Clin Respir J. 2018;12(3):1240-6.
  • 41
    Laveneziana P, Albuquerque A, Aliverti A, Babb T, Barreiro E, Dres M, et al. ERS statement on respiratory muscle testing at rest and during exercise. Eur Respir J. 2019;53(6):1801214.
  • 42
    Jackson AC. Accuracy, reproducibility, and variability of portable peak flowmeters. Chest. 1995;107(3):648-51.
  • 43
    Miller MR, Dickinson SA, Hitchings DJ. The accuracy of portable peak flow meters. Thorax. 1992;47(11):904-9.
  • 44
    Menon N, Joffe AM, Deem S, Yanez ND, Grabinsky A, Dagal AH, et al. Occurrence and complications of tracheal reintubation in critically ill adults. Respir Care. 2012;57(10):1555-63.
  • 45
    Maggiore SM, Battilana M, Serano L, Petrini F. Ventilatory support after extubation in critically ill patients. Lancet Respir Med. 2018;6(12):948-62.
  • 46
    Song F, Khan KS, Dinnes J, Sutton AJ. Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy. Int J Epidemiol. 2002;31(1):88-95.

Edited by

Responsible editor: Leandro Utino Taniguchi

Publication Dates

  • Publication in this collection
    25 Oct 2021
  • Date of issue
    Jul-Sep 2021

History

  • Received
    16 Aug 2020
  • Accepted
    20 Jan 2021
Associação de Medicina Intensiva Brasileira - AMIB Rua Arminda, 93 - Vila Olímpia, CEP 04545-100 - São Paulo - SP - Brasil, Tel.: (11) 5089-2642 - São Paulo - SP - Brazil
E-mail: rbti.artigos@amib.com.br