Tensile Strength of Resin Cements Used with Base Metals in a Simulating Passive Cementation Technique for Implant-Supported Prostheses

Abstract

The aim of this study was to analyze the tensile strength of two different resin cements used in passive cementation technique for implant-supported prosthesis. Ninety-six plastic cylinders were waxed in standardized forms, cast in commercially pure titanium, nickel-chromium and nickel-chromium-titanium alloys. Specimens were cemented on titanium cylinders using self-adhesive resin cement or conventional dual-cured resin cement. Specimens were divided in 12 groups (n=8) in accordance to metal, cement and ageing process. Specimens were immersed in distilled water at 37 °C for 24 h and half of them was thermocycled for 5,000 cycles. Specimens were submitted to bond strength test in a universal test machine EMIC-DL2000 at 5 mm/min speed. Statistical analysis evidenced higher tensile strength for self-adhesive resin cement than conventional dual-cured resin cement, whatever the used metal. Self-adhesive resin cement presented higher tensile strength compared to conventional dual-cured resin cement. In conclusion, metal type and ageing process did not influence the tensile strength results.

Key Words:
implant; implant-supported prosthesis; resin cement; tensile strength; self-adhesive cement; dual resin cement.

Resumo

O objetivo deste estudo foi analisar a resistência à tração de dois diferentes cimentos resinosos usados na técnica de cimentação passiva de próteses implanto-suportadas. Noventa e seis cilindros plásticos foram encerados em formas padronizadas, fundidos em titânio grau 2 comercialmente puro e ligas de níquel-cromo e níquel-cromo-titânio. Amostras foram cimentadas sobre cilindros de titânio usando um cimento auto-adesivo ou um cimento convencional de dupla polimerização. Os espécimes foram divididos em 12 grupos (n=8) de acordo com o metal, cimento e processo de envelhecimento. Espécimes foram imersos em água destilada a 37 °C por 24 h e metade deles foi termociclado por 5,000 ciclos. Espécimes foram submetidos ao ensaio de tração numa máquina universal de ensaios (velocidade de 5 mm/min). Análise estatística evidenciou maior resistência à tração do cimento auto adesivo do que o cimento convencional de dupla polimerização, independente do metal utilizado. O cimento resinoso auto adesivo apresentou maior resistência à tração do que o cimento convencional de dupla polimerização. O tipo de metal e o processo de envelhecimento não tiveram influência nos resultados.

Introduction

The osseointegration has been studied for years, as well as some techniques for rehabilitation with implant-supported prostheses that have been developed and constantly improved. The implant reconstructions present excellent clinical survival rates11 Sailer, I; Muhlemann, S; Zwahlen, M; Hammerle, CH; Schneider, D. Cemented and screw-retained implant reconstructions: A systematic review of the survival and complication rates. Clin Oral Implants Res 2012;23(suppl 6):163-201..

One of the important decisions in implant prosthodontics is the choice of the connection type that can be either screw- or cement-retained. Both retention types have their advantages and limitations. The choice is based on ease of fabrication, precision, passivity of the framework, retention provided by cement and abutment occlusion, esthetics, accessibility, retrievability, complications and cost22 Wittneben, JG; Millen, C; Bragger, U. Clinical performance of screw-versus cement-retained fixed implant-supported reconstructions - A systematic review. Int J Oral Maxillofac Implants 2014;29(suppl):84-98..

Cemented prosthesis appears to minimize pressure on the implants caused by the misfit of frameworks and absorbs a part of the load exerted on the implants33 Guichet, DL; Caputo, AA; Choi, H; Sorensen, JA. Passivity of fit and marginal opening in screw or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000;15:239-245.. However, a possible technical problem associated with the cementation is the de-cementation failure of the prosthesis11 Sailer, I; Muhlemann, S; Zwahlen, M; Hammerle, CH; Schneider, D. Cemented and screw-retained implant reconstructions: A systematic review of the survival and complication rates. Clin Oral Implants Res 2012;23(suppl 6):163-201.. The cemented cylinder technique is a form of rehabilitation with implants that allows complete or partial prosthesis supposedly passive fit to the implant restoration, keeping the advantage of retrievability inherent to screwed prosthesis22 Wittneben, JG; Millen, C; Bragger, U. Clinical performance of screw-versus cement-retained fixed implant-supported reconstructions - A systematic review. Int J Oral Maxillofac Implants 2014;29(suppl):84-98..

Passive fit of implant-supported prosthesis seems to be a prerequisite for the prevention of mechanical complications33 Guichet, DL; Caputo, AA; Choi, H; Sorensen, JA. Passivity of fit and marginal opening in screw or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000;15:239-245. and enhances the quality of restorations44 Mansour, A; Ercoli, C; Graser, G; Tallents, R; Moss, M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin. Oral Impl Res 2002;13:343-348.. The cementation of titanium frameworks improves the passive fit because the cement space between abutment and titanium cylinder may compensate for fit discrepancies33 Guichet, DL; Caputo, AA; Choi, H; Sorensen, JA. Passivity of fit and marginal opening in screw or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000;15:239-245.,44 Mansour, A; Ercoli, C; Graser, G; Tallents, R; Moss, M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin. Oral Impl Res 2002;13:343-348.,55 Greven, B; Luepke, M; Von Dorsche, SH. Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit. J Prosthet Dent 2007;98:239-244.,66 Michalakis, KX; Hirayama, H; Garefis, PD. Cement-retained versus screw retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;15:719-728.. The choice of luting agent is one of most important factors controlling the amount of retention and is critical to the passivity66 Michalakis, KX; Hirayama, H; Garefis, PD. Cement-retained versus screw retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;15:719-728.,77 Osman, SA; McCabe, JF; Walls, AW. Bonding adhesive resin luting agents to metal and amalgam. Eur J Prosthodont Restor Dent 2008;16:171-176.,88 Cicciù, M; Beretta, M; Risitano, G; Maiorana, C. Cement-retained vs screw-retained implant restorations: an investigation on 1939 dental implants. Minerva Stomatologica 2008;57:167-179..

The used cement must have favorable biological and mechanical properties due to the sensitivity of the technique especially when performed for the immediate load technique. The choice of the cement is one the most important factors controlling the amount of retention to prevent dislodgement of the titanium cylinders.66 Michalakis, KX; Hirayama, H; Garefis, PD. Cement-retained versus screw retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;15:719-728.. As consequence, the dislodgement could cause deleterious micro movements and the concentration of loads in some implants may cause failures44 Mansour, A; Ercoli, C; Graser, G; Tallents, R; Moss, M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin. Oral Impl Res 2002;13:343-348.,99 Karl, M; Wichmann, MG; Winter, W; Graef, F; Taylor, TD; Heckman, SM. Influence of fixation mode and superstructure span upon strain development of implant fixed partial dentures. J Prosthodont 2008;17:3-8.,1010 Yannikakis, S; Prombonas, A. Improving the fit of implant prosthetics: an in vitro study. Int J Oral Maxillofac Implants 2013;28:126-134..

The aim of this study was evaluate the tensile strength of two different resin cements used to fix titanium cylinders in a passive cementation technique of implant-supported prosthesis.

Material and Methods

Micro Unit abutment analog (Conexão Sistemas de Prótese, Arujá, SP, Brazil) was fixed in the center of a polytetrafluoroethylene cylinder for waxing the samples. Over this analog space, ring (Conexão) and its respective plastic cylinder (Conexão) were positioned and screwed. Ninety-six specimens (9 mm high x 9 mm lower diameter x 11 mm upper diameter) were waxed and cast (n=32) using commercially pure titanium (cp Ti grid 2; Realum, São Paulo, SP, Brazil), nickel-chromium (NiCr,Verabond 2; Alba Dental, Cordelia, CA, USA) and nickel-chromium-titanium (NiCrTi, Tilite Omega; Talladium, Valencia, CA, USA).

Patterns were included with specific investments, Rematitan Plus (Dentaurum, Pforzheim, Germany) was used for commercially pure titanium (cp Ti) and Rema Exakt (Dentaurum) was used for nickel-chromium (NiCr) and nickel-chromium-titanium (NiCrTi) alloys. Investments were mixed in a vacuum machine (Turbomix; EDG, São Carlos, SP, Brazil) and inclusion made in stainless steel rings. After 40 min, rings were placed in a heating oven (10 P-S; EDG). Casting of cp Ti occurred when the temperature of the investment preheating reached 430 °C and for NiCr and NiCrTi alloys accomplished when temperature of 950 °C were reached. Castings were done in a Discovery Plasma (EDG) furnace that promotes fusion through voltaic arc current of the tungsten electrode, under vacuum and inert argon atmosphere.

After divesting, the samples were submitted to airborne-particle abrasion using 100 µm aluminum oxide particles at an emission pressure of 90 psi for 10 s at a standardized 45° incidence angle and ultrasonically cleaned (Ultrasonic Cleaner; Odontobras, Ribeirão Preto, SP, Brazil) with isopropyl alcohol (Labsynth, Diadema, SP, Brazil) for 10 min.

Titanium cylinder (Conexão) was placed on the Micro Unit abutment and screwed with 10 Ncm torque by a manual torquemeter (Conexão). Over this titanium cylinder samples (copings) were individually cemented with the aid of a surveyor in the central position of the Micro Unit abutment (Conexão).

Panavia F (Kuraray, Fujimoto, Japan) or RelyX U100 (3M ESPE, Seefeld, Germany) was applied in half the samples Alloy Primer (Kuraray) was used for conditioning the metal surface etching when Panavia F was employed. Cements were handled according to the guidelines of the manufacturers, inserted into samples and positioned over the titanium cylinders. After removing excess of cement, a 5 kg-load was applied over the samples for 10 min. Cements were cured with a halogen lamp (Ultralux; Dabi Atlante, Ribeirão Preto, SP, Brazil) at 450 mW/cm2 for 20 s at each side (mesial, distal, buccal, lingual and occlusal) totaling 100 s for each sample, and maintained under a 5 kg load of for 10 min44 Mansour, A; Ercoli, C; Graser, G; Tallents, R; Moss, M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin. Oral Impl Res 2002;13:343-348.,88 Cicciù, M; Beretta, M; Risitano, G; Maiorana, C. Cement-retained vs screw-retained implant restorations: an investigation on 1939 dental implants. Minerva Stomatologica 2008;57:167-179.,1111 Spazzin, AO; Spazzin, WO; Schuh, C; Bacchi, A; Tosta, VB; Marcaccini, AM. Technique of framework cemented on prepared abutments to obtain passive fit at fixed complete denture: A 2-year follow-up report. Braz Dent J. 2014;25:565-570.. The samples of Panavia F group were kept with an Oxyguard (Kuraray) layer at the margins during the same period.

After cementation, the samples were stored in distilled water at 37 °C for 24 h. Half he samples were submitted to tensile strength test in a universal test machine (EMIC DL2000; EMIC, São Carlos, Brazil) with a 5 mm/min speed1212 Stewart, GP; Jain, P; Hodges, J. Shear bond strength of resin cements to both ceramic and dentin. J Prosthet Dent 2002;88:277-284.,1313 Wadhwani, C; Chung, KH. Bond strength and interactions of machined titanium-based alloy with dental cements. J Prosthet Dent 2015Nov;114:660-665. and 500 kgf load cell. The other half was thermocycled for 5,000 cycles with temperature bath of 5 and 55 °C, and next subjected to bond strength test (Table 1).

Table 1
Experimental studied groups

Statistical analysis was performed with SPSS for windows (SPSS/PC for Windows Inc., Chicago, IL, USA) and p values of less than 0.05 were considered significant. For the tested tensile strength variable, adhesion to the normal distribution and homogeneity of variances were analyzed by Kolmogorov-Smirnov and Levene tests, respectively.

The comparison was performed using three-way ANOVA (cement, metal and ageing factors). The interaction among factors (5%) was also investigated.

Results

Kolmogorov-Smirnov statistical test showed that the rate and tensile strength variables had a normal distribution and the Levene test showed homogeneity of variances, which allowed comparisons using parametric methods.

No statistically significant difference (p>0.05) was found for the metal and ageing process factors and their interactions.

The cementing agent factor showed a statistically significant difference between cements, regardless the type of metal and ageing process before or after thermocycling, and the highest values of tensile strength were for RelyX U100 cementing agent (Fig. 1).

Figure 1
Mean and standard deviation of tensile strength of different studied groups (N).

Discussion

Resin cement showed different values for tensile strength. The self-adhesive resin cement (RelyX U100) presented higher tensile strength when used to fix titanium cylinders in passive cementing technique with values varying from 535.3±96 to 676.2±188 N after 24 h and from 556.5±131 to 698.1±195 N after 30 days of ageing process.

In the present study, Panavia F cement, using a conditioner, showed mean values of tensile strength varying from 504±206 to 540.2±195 N after 24 h and from 377±120 to 516.5±109 N after 30 days of ageing process.

Panavia contains the organic ester 10-methacryloyloxi-decyl-dihydrogen-phosphate (MDP) which has the property of bonding the primer monomer and metal oxides44 Mansour, A; Ercoli, C; Graser, G; Tallents, R; Moss, M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin. Oral Impl Res 2002;13:343-348.,1414 Yoshida, K; Tanagawa, M; Atsuta, M. In vitro solubility of three types of resin and conventional luting cements. J Oral Rehabil 1998;25:285-291.. Then, the results obtained with Panavia F can be justified by the presence of residual monomer or solvent like ethanol and acetone from conditioner primers1515 Fonseca, RG; Almeida, JG; Haneda, IG; Adabo, GL. Effect of metal primers on bond strength of resin cements to base metals. J Prosthet Dent 2009;101:262-268.. It is suggested that the negative influence of VBATDT monomer (6-(4-vinylbenzyl-h-propyl) amino-1,2,5-tiazine-2,4-dithione), in the Alloy Primer, disturbs the polymerization reaction of resin-based materials that contain the benzoyl peroxide-amine initiator system. This monomer may interfere in the reaction between the MDP of the primer and the cement and/or metal oxides1515 Fonseca, RG; Almeida, JG; Haneda, IG; Adabo, GL. Effect of metal primers on bond strength of resin cements to base metals. J Prosthet Dent 2009;101:262-268..

Temperature range between 5 and 55 °C did not cause mechanical changes on the cohesive strength of resin cement to weaken metal/cement bond. The ageing process in distilled water (24 h) and thermocycling (30 days) may be unsufficient for the hydrolysis process, because lower sorption and solubility may avoid water diffusion1515 Fonseca, RG; Almeida, JG; Haneda, IG; Adabo, GL. Effect of metal primers on bond strength of resin cements to base metals. J Prosthet Dent 2009;101:262-268..

RelyX U100, (methacrylate phosphoric acid esters) is classified by the manufacturer as self-adhesive resin cement and contains hydrophilic monomers and acids, demineralizing and infiltrating the enamel and dentin1616 Vrochari, AD; Eliades, G; Hellwig, E; Arbas, KT. Curing efficiency of four self-etching, self-adhesive resin cements. Dent Mater 2009; 25:1104-1108.. Base metals provide a more reactive surface for bonding to the resin cement because they have higher free-surface energy and are more reactive than precious metal alloys, forming a thicker oxide layer that roughens the metal surface providing micromechanical retention1717 Abreu, A; Loza, MA; Elias, A; Mukhopadhyay, S; Looney, S; Rueggeberg, FA. Tensile bond strength of an adhesive resin cement to different alloys having various surface treatments. J Prosthet Dent 2009;101:107-118..

RelyX U100 cementing agent showed a statistically greater average tensile strength (N) compared to Panavia F. The highest mean retention was obtained when a Tilite (NiCrTi) structure was cemented with RelyX U100 and subjected to thermocycling for 5,000 cycles (698.1±195 N). This result suggests further evaluation of this agent for cementation but offers a perspective with easy access and convenient use.

The resin cements are materials composed of a Bis-GMA (bisphenol A-glycidyl methacrylate) or UDMA (urethane dimethacrylate) matrix and silane-treated small particles of inorganic load. A group of these cements has adhesive monomers in the composition of a system part, which chemically adhere to the metal. They are called adhesive cements and are able to efficiently join the oxides. The high reactivity of base metal alloys makes them more appropriate for the restoration of preparations with small surface area1616 Vrochari, AD; Eliades, G; Hellwig, E; Arbas, KT. Curing efficiency of four self-etching, self-adhesive resin cements. Dent Mater 2009; 25:1104-1108.,1818 Abreu, A; Loza, MA; Elias, A; Mukhopadhyay, S; Rueggeberg, FA. Effect of metal type and surface treatment on in vitro tensile strength of copings cemented to minimally retentive preparations. J Prosthet Dent 2007;98:199-207..

The chemical bond of resin cement can enhance the performance of conditioner primers, which, with bifunctional monomers with one end containing mercaptan or thiol groups (-SH), are able to optimize the metal alloys bond. Some types of adhesive monomers are the 10-MDP and VBATDT that are in the Alloy Primer, the conditioner of the Panavia F cement system.

The effectiveness of the primers for bonding resin cements to precious metal alloys and base metal alloys was confirmed in some studies 1919. Ishikawa, Y; Kawamoto, Y; Koizumi, H; Furuchi, M; Matsumura, H; Tanoue, N. Effect of metal priming agents on bonding characteristics of an acrylic resin joined to SUS XM27 steel. J Oral Sci 2006;48:215-218.,2020 Furuchi, M; Oshima, A; Ishikawa, Y; Koizumi, H; Tanoue, N; Matsumura, H. Effect of metal priming agents on bond strength of resin-modified glass ionomers joined to gold alloy. Dent Mater J 2007;26:728-732.,2121 Silikas, N; Wincott, PL; Vaughan, D; Watts, DC; Eliades, G. Surface characterization of precious alloy treated with thione metal primers. Dent Mater 2007;23:665-673.,2222 Serafionou, A; Seimenis, I; Papadopoulos, T. Effectiveness of different adhesive primers on the bond strength between an indirect composite resin and a base metal alloy. J Prosthet Dent 2008;99:377-387.,2323 Taira, Y; Kamada, K; Atsuta, M. Effects of primer containing sulfur and phosphate monomers on bonding of resin to Ag-Pd-Au alloy. Dent Mater J 2008;27:69-74.. Self-adhesive cements are a nonhomogeneous group with regard to their bond values and chemical composition and differ significantly in their bonding to base metal alloys2424 Hattar, S; Hatamleh, M; Khraisat, A; Al-Rabab-ah, M. Shear bond strength of self-adhesive resin cements to base alloy. J Prosthet Dent 2014;111:411-415..

The oxide layer formed over cp titanium produces a firm oxide adherent layer that does not influence the bond strength of self-adhesive resin cements2525 Menani, LR; Ribeiro, RF; Antunes, RPA. Tensile bond strength of cast commercially pure titanium and cast gold-alloy posts and cores cemented with two luting agents. J Prosthet Dent 2008;99:141-147.. However, the bond strength of the cements varies depending on the prosthodontic substrate, indicating that selection of these cements should be dictated by the substrate2626 Sabatini, C; Patel, M; Silva, E. In vitro shear bond strength of three self-adhesive rein cements and a resin-modified glass ionomer cement to various prosthodontics substrates. Oper Dent 2013;38:186-196.

Certain properties of resin cements compared are superior to other types of cements, like greater fracture resistance1818 Abreu, A; Loza, MA; Elias, A; Mukhopadhyay, S; Rueggeberg, FA. Effect of metal type and surface treatment on in vitro tensile strength of copings cemented to minimally retentive preparations. J Prosthet Dent 2007;98:199-207.,2727 Dalen, A; Feilzer, AJ; Kleverlaan, CJ. In vitro exploration and finite element analysis of failure mechanisms of resin-bonded fixed partial dentures. J Prosthodont 2008;17:555-561.,2828 Attar, N; Tam, LE; McComb, D. Mechanical and physical properties of contemporary dental luting agents. J. Prosthet. Dent 2003;89:127-134., good adherence to dental structures and alloys provided by adhesive systems2929 Pan, YH; Ramp, LC; Lin, CK; Liu, PR. Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration. Int J Oral Maxillofac Implants 2006;21:587-592.,3030 Orsi, IA; Vardi, FK; Pieroni, CHP; Ferreira ,MCCG; Borie, E. In vitro tensile strength of luting cements on metallic substrates. Braz Dent J 2014;25:136-140., low solubility in oral fluids, in addition to the reduced leakage in restorations2929 Pan, YH; Ramp, LC; Lin, CK; Liu, PR. Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration. Int J Oral Maxillofac Implants 2006;21:587-592., make the resin cements agents of choice for cementation. It is claimed that there is no established value of load considered ideal for clinical success of prosthesis retention3030 Orsi, IA; Vardi, FK; Pieroni, CHP; Ferreira ,MCCG; Borie, E. In vitro tensile strength of luting cements on metallic substrates. Braz Dent J 2014;25:136-140..

The traditional system of building a metal framework by melting over mechanized pieces called cylinders was modified. The cylinders are joined to the metal framework by physicochemical bonding. A passive cementing technique is a viable alternative, as well as others whose main purpose is the ability to compensate possible distortions in the metal framework that could generate undesirable loads to the implants88 Cicciù, M; Beretta, M; Risitano, G; Maiorana, C. Cement-retained vs screw-retained implant restorations: an investigation on 1939 dental implants. Minerva Stomatologica 2008;57:167-179.,1111 Spazzin, AO; Spazzin, WO; Schuh, C; Bacchi, A; Tosta, VB; Marcaccini, AM. Technique of framework cemented on prepared abutments to obtain passive fit at fixed complete denture: A 2-year follow-up report. Braz Dent J. 2014;25:565-570..

In this study, the standard form of preparation and use of segments of the framework allowed comparing only the efficiency of the physicochemical bond of the tested cementing agents, without change in any other factor. The substrate surfaces were similar due the airborne-particle abrasion applied to all samples.

The alloys behaved similarly despite the cp Ti providing a more stable oxidation layer1515 Fonseca, RG; Almeida, JG; Haneda, IG; Adabo, GL. Effect of metal primers on bond strength of resin cements to base metals. J Prosthet Dent 2009;101:262-268.. In this study, the tensile bond strength of cements was similar in all tested metals. This similarity between the metals was possibly due to the standardization of surface, cylinder form and samples.

The chemical bond occurred on all metals regardless of chemical composition of the oxide layer on the surface of samples. The MDP and VBTDT adhesive monomers of Panavia F system and the phosphoric acid esters of methacrylate of RelyX U100 provided good adhesion to different substrates used in this study.

Although the present results show no differences between the different alloys, it is important to choose the nature of the material to be used77 Osman, SA; McCabe, JF; Walls, AW. Bonding adhesive resin luting agents to metal and amalgam. Eur J Prosthodont Restor Dent 2008;16:171-176.) in regard to other mechanical properties and biological action. Further studies should be conducted to evaluate other biological and mechanical properties of materials evaluated in this study.

According to the employed methodology, it may be concluded that the self-adhesive resin cement used to cement titanium cylinders on different metallic copings in passive cementation technique of implant-supported prosthesis presented higher tensile strength when compared to conventional dual-cured resin cement. Metal and ageing process do not influence tensile results at in the different studied situations.

Acknowledgements

The authors would like to thank The São Paulo State Research Foundation FAPESP (Grant 06-56702-9) for the financial support to this study.

References

  • 1
    Sailer, I; Muhlemann, S; Zwahlen, M; Hammerle, CH; Schneider, D. Cemented and screw-retained implant reconstructions: A systematic review of the survival and complication rates. Clin Oral Implants Res 2012;23(suppl 6):163-201.
  • 2
    Wittneben, JG; Millen, C; Bragger, U. Clinical performance of screw-versus cement-retained fixed implant-supported reconstructions - A systematic review. Int J Oral Maxillofac Implants 2014;29(suppl):84-98.
  • 3
    Guichet, DL; Caputo, AA; Choi, H; Sorensen, JA. Passivity of fit and marginal opening in screw or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000;15:239-245.
  • 4
    Mansour, A; Ercoli, C; Graser, G; Tallents, R; Moss, M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin. Oral Impl Res 2002;13:343-348.
  • 5
    Greven, B; Luepke, M; Von Dorsche, SH. Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit. J Prosthet Dent 2007;98:239-244.
  • 6
    Michalakis, KX; Hirayama, H; Garefis, PD. Cement-retained versus screw retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;15:719-728.
  • 7
    Osman, SA; McCabe, JF; Walls, AW. Bonding adhesive resin luting agents to metal and amalgam. Eur J Prosthodont Restor Dent 2008;16:171-176.
  • 8
    Cicciù, M; Beretta, M; Risitano, G; Maiorana, C. Cement-retained vs screw-retained implant restorations: an investigation on 1939 dental implants. Minerva Stomatologica 2008;57:167-179.
  • 9
    Karl, M; Wichmann, MG; Winter, W; Graef, F; Taylor, TD; Heckman, SM. Influence of fixation mode and superstructure span upon strain development of implant fixed partial dentures. J Prosthodont 2008;17:3-8.
  • 10
    Yannikakis, S; Prombonas, A. Improving the fit of implant prosthetics: an in vitro study. Int J Oral Maxillofac Implants 2013;28:126-134.
  • 11
    Spazzin, AO; Spazzin, WO; Schuh, C; Bacchi, A; Tosta, VB; Marcaccini, AM. Technique of framework cemented on prepared abutments to obtain passive fit at fixed complete denture: A 2-year follow-up report. Braz Dent J. 2014;25:565-570.
  • 12
    Stewart, GP; Jain, P; Hodges, J. Shear bond strength of resin cements to both ceramic and dentin. J Prosthet Dent 2002;88:277-284.
  • 13
    Wadhwani, C; Chung, KH. Bond strength and interactions of machined titanium-based alloy with dental cements. J Prosthet Dent 2015Nov;114:660-665.
  • 14
    Yoshida, K; Tanagawa, M; Atsuta, M. In vitro solubility of three types of resin and conventional luting cements. J Oral Rehabil 1998;25:285-291.
  • 15
    Fonseca, RG; Almeida, JG; Haneda, IG; Adabo, GL. Effect of metal primers on bond strength of resin cements to base metals. J Prosthet Dent 2009;101:262-268.
  • 16
    Vrochari, AD; Eliades, G; Hellwig, E; Arbas, KT. Curing efficiency of four self-etching, self-adhesive resin cements. Dent Mater 2009; 25:1104-1108.
  • 17
    Abreu, A; Loza, MA; Elias, A; Mukhopadhyay, S; Looney, S; Rueggeberg, FA. Tensile bond strength of an adhesive resin cement to different alloys having various surface treatments. J Prosthet Dent 2009;101:107-118.
  • 18
    Abreu, A; Loza, MA; Elias, A; Mukhopadhyay, S; Rueggeberg, FA. Effect of metal type and surface treatment on in vitro tensile strength of copings cemented to minimally retentive preparations. J Prosthet Dent 2007;98:199-207.
  • 19
    Ishikawa, Y; Kawamoto, Y; Koizumi, H; Furuchi, M; Matsumura, H; Tanoue, N. Effect of metal priming agents on bonding characteristics of an acrylic resin joined to SUS XM27 steel. J Oral Sci 2006;48:215-218.
  • 20
    Furuchi, M; Oshima, A; Ishikawa, Y; Koizumi, H; Tanoue, N; Matsumura, H. Effect of metal priming agents on bond strength of resin-modified glass ionomers joined to gold alloy. Dent Mater J 2007;26:728-732.
  • 21
    Silikas, N; Wincott, PL; Vaughan, D; Watts, DC; Eliades, G. Surface characterization of precious alloy treated with thione metal primers. Dent Mater 2007;23:665-673.
  • 22
    Serafionou, A; Seimenis, I; Papadopoulos, T. Effectiveness of different adhesive primers on the bond strength between an indirect composite resin and a base metal alloy. J Prosthet Dent 2008;99:377-387.
  • 23
    Taira, Y; Kamada, K; Atsuta, M. Effects of primer containing sulfur and phosphate monomers on bonding of resin to Ag-Pd-Au alloy. Dent Mater J 2008;27:69-74.
  • 24
    Hattar, S; Hatamleh, M; Khraisat, A; Al-Rabab-ah, M. Shear bond strength of self-adhesive resin cements to base alloy. J Prosthet Dent 2014;111:411-415.
  • 25
    Menani, LR; Ribeiro, RF; Antunes, RPA. Tensile bond strength of cast commercially pure titanium and cast gold-alloy posts and cores cemented with two luting agents. J Prosthet Dent 2008;99:141-147.
  • 26
    Sabatini, C; Patel, M; Silva, E. In vitro shear bond strength of three self-adhesive rein cements and a resin-modified glass ionomer cement to various prosthodontics substrates. Oper Dent 2013;38:186-196.
  • 27
    Dalen, A; Feilzer, AJ; Kleverlaan, CJ. In vitro exploration and finite element analysis of failure mechanisms of resin-bonded fixed partial dentures. J Prosthodont 2008;17:555-561.
  • 28
    Attar, N; Tam, LE; McComb, D. Mechanical and physical properties of contemporary dental luting agents. J. Prosthet. Dent 2003;89:127-134.
  • 29
    Pan, YH; Ramp, LC; Lin, CK; Liu, PR. Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration. Int J Oral Maxillofac Implants 2006;21:587-592.
  • 30
    Orsi, IA; Vardi, FK; Pieroni, CHP; Ferreira ,MCCG; Borie, E. In vitro tensile strength of luting cements on metallic substrates. Braz Dent J 2014;25:136-140.

Publication Dates

  • Publication in this collection
    Oct-Dec 2016

History

  • Received
    26 Nov 2015
  • Accepted
    20 Sept 2016
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br