Acessibilidade / Reportar erro

Reinforced Glass-ceramics: Parametric Inspection of Three-Dimensional Wear and Volumetric Loss after Chewing Simulation

Abstract

The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.

Key Words:
ceramics; wear simulation; volume loss

Resumo

O objetivo deste estudo foi investigar o desgaste tridimensional, perda volumétrica e rugosidade após a simulação de mastigação de dois materiais vitro-cerâmicos. Discos de dissilicato de lítio (LD, Emax CAD, Ivoclar) e silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity, Vita Zhanfabrick) (n=20/g) foram confeccionados e digitalizados para obtenção de arquivos de estereolitografia (STL) de cada amostra. Todos os discos foram submetidos à simulação de mastigação com configuração deslizante (30 N, 300.000 ciclos, 6 mm e 1,7 Hz) com esteatita como antagonista. As amostras foram escaneadas novamente e a perda de volume e o defeito mais profundo foram medidos usando o arquivo sobreposto da linha de base através de um software de inspeção paramétrica digital e tridimensional (GOM Inspect, Braunschweig, Alemanha). A rugosidade superficial (Ra e Rz) foi avaliada através de rugosímetro de contato. Os resultados foram analisados por ANOVA 1-fator e teste Tukey (α=0,5%). ANOVA mostrou diferenças significantes entre os grupos. Considerando a perda de volume cerâmico, comprimento do defeito e rugosidade Rz, LD (-22,09±5,57%; 0,80±0,06 µm; 3,08±1.02 µm) apresentou valores médios superiores a ZLS (-15,67±4,51%; 0,56±0,09 µm; 1.51±0.90 µm). Todos os discos exibiram pequenos arranhões na superfície conforme a direção de deslizamento com padrões de desgaste, enquanto grandes ranhuras foram observadas nos traços de desgaste. Essas mesmas áreas podem ser identificadas em azul, sobrepondo os arquivos STL antes e depois da simulação de mastigação no software de inspeção. A redução linear gerada pelo contato deslizante mostra um gráfico com uma forma de padrão de desgaste semelhante. ZLS foi mais resistente ao desgaste do que LD, com menor perda de volume e menores defeitos superficiais.

Introduction

The incorporation of crystalline particles inside glasses matrices enables dental ceramics to reach high fracture resistance due to smaller crack propagations without compromising the final aesthetics 11 Pieger, S; Salman, A; Bidra, AS. Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review. J Prosthet Dent2014;112:22-30.. Among the main ceramics used in dentistry, lithium disilicate ceramics are noteworthy for their extensive indication: veneers, inlays, onlays 11 Pieger, S; Salman, A; Bidra, AS. Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review. J Prosthet Dent2014;112:22-30., monolithic crowns 11 Pieger, S; Salman, A; Bidra, AS. Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review. J Prosthet Dent2014;112:22-30.,22 Dal Piva, AMO; Tribst, JPM; Borges, ALS; Souza, ROAE; Bottino, MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater2018;S0109-5641:30026-30035., copings, fixed prostheses 11 Pieger, S; Salman, A; Bidra, AS. Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review. J Prosthet Dent2014;112:22-30., hybrid abutments 33 Tribst, JPM; Dal Piva, AMO; Borges, ALS; Bottino, MA. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis. Rev Odontol UNESP 2018;47:149-154. and endocrowns 44 Tribst, JPM; Dal Piva, AMO; Madruga, CFL; Valera, MC; Borges, ALS; Bresciani, E; et al. Endocrown restorations: Influence of dental remnant and restorative material on stress distribution. Dent Mater 2018;S0109-5641:31303-31309.. Another ceramic with a similar function is zirconia reinforced lithium silicate, possessing reinforcement crystals in the monosilicate phase instead of disilicate. In addition, zirconia particles were incorporated inside the glass matrix to promote better mechanical properties when subjected to masticatory forces 55 Elsaka, SE; Elnaghy, AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater 2016;32:908-914..

Despite the difference in composition, the literature is not as concise regarding the differences between lithium disilicate and zirconia reinforced lithium silicate materials. There are reports of superior strength in zirconia reinforced lithium silicate 66 Zimmermann, M; Egli, G; Zaruba, M; Mehl, A. Influence of material thickness on fractural strength of CAD/CAM fabricated ceramic crowns. Dent Mater J2017:29;36:778-783.,77 Hamza, TA; Sherif, RM. Fracture resistance of monolithic glass-ceramics versus bilayered zirconia-based restorations. J Prosthodont 2019;28:e259-e264. and reports of superior strength in lithium disilicate 88 Sieper, K; Wille, S; Kern, M. Fracture strength of lithium disilicate crowns compared to polymer-infiltrated ceramic-network and zirconia reinforced lithium silicate crowns. J Mech Behav Biomed Mater 2017;74:342-348., or even similar mechanical behavior between them 22 Dal Piva, AMO; Tribst, JPM; Borges, ALS; Souza, ROAE; Bottino, MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater2018;S0109-5641:30026-30035.. Therefore, other criteria should also be considered to help the clinician in choosing which material to use. Likewise, long-term investigations should be performed to evaluate the behavior of these materials.

A methodology that simulates a longitudinal evaluation is the wear resistance of restorative materials 99 Naumova, EA; Schneider, S; Arnold, WH; Piwowarczyk, A. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists. Materials ( Basel) 2017;10:E244.,1010 Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334.. A material with good resistance to wear will not modify the patient’s vertical dimension, nor the restoration shape and its consequent aesthetics. The wear resistance of lithium disilicate is reported to be adequate as it does not decrease the restoration volume during chewing, nor cause excessive wear on the antagonist dentition 1010 Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334.,1111 Matzinger, M; Hahnel, S; Preis, V; Rosentritt, M. Polishing effects and wear performance of chairside CAD/CAM materials. Clin Oral Investig 2019;23:725-737.. Several studies report that this material can experience wear differently in the oral environment due to its individual mechanical properties, and micro- and macrostructural composition 1111 Matzinger, M; Hahnel, S; Preis, V; Rosentritt, M. Polishing effects and wear performance of chairside CAD/CAM materials. Clin Oral Investig 2019;23:725-737.,1212 Lawson, NC; Bansal, R; Burgess, JO. Wear, strength, modulus and hardness of CAD/CAM thyrestorative materials. Dent Mater 2016;32:e275-e283.,1313 Oh, WS; Delong, R; Anusavice, KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent 2002;87:451-459..

Since zirconia reinforced lithium silicate is a ceramic possessing different reinforcing crystals other than lithium disilicate, it is important to ascertain whether they have similar indications if both materials are capable of maintaining their integrity after simulated wear. Based on this concern, some studies have evaluated the wear caused by the natural dentition in zirconia reinforced lithium silicate ceramics 1010 Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334.,1414 Heintze, SD; Cavalleri, A; Forjanic, M; Zellweger, G; Rousson, V. Wear of ceramic and antagonist--a systematic evaluation of influencing factors in vitro. Dent Mater 2008;24:433-439., and comparing these results with the results for lithium disilicate ceramic wear. Since the data obtained by a direct comparison are important, it is necessary to verify the performance of these materials throughout the surface. Moreover, the parametric inspection of the scanning files before and after the wear simulation can enable verifying the volume loss and the depth of the generated defects. In the proposed method, the specimen is verified as a whole and not just a single area, as in the case of the analysis by profilometry or surface roughness 99 Naumova, EA; Schneider, S; Arnold, WH; Piwowarczyk, A. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists. Materials ( Basel) 2017;10:E244..

Thus, the goal of this study was to compare the volume loss and the depth of wear generated after wear simulation in two dental ceramics using a three-dimensional parametric inspection and scanning electron microscopy. The null hypothesis was that there would be no difference between the ceramics under the evaluated criteria.

Material and Methods

Samples Preparation

Two CAD/CAM (Computer Aided Design/Computer Aided Manufacture) ceramic materials were selected: lithium disilicate glass ceramics [(IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) - subgroup LD] and zirconia reinforced lithium silicate [(Vita Suprinity, VITA Zahnfabrik H. Rauter GmbH & Co., BadSäckingen, Germany) - subgroup ZLS]. Two blocks of each material were rounded in an automatic orbital sander (Ecomet 250 ; Buehler, Lake Bluff, IL, USA) using water sandpaper with grain size #600. Next, the rollers were cut using a precision cutting machine (Isomet 1000, Buehler) into 2-mm thick disc specimens under constant water irrigation to fabricate the disc specimens (n=20, n=40). All specimens were finished with an applied force of 33N at a speed of 100 rpm for 5 min with different grits of silicon carbide grinding papers (120, 240, 320, 600,1200 grit) and polishing with specific rubber points in order to assure surface smoothness and parallelism before the wear simulation 1010 Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334.. Afterwards, all samples were cleaned with isopropyl alcohol in an ultrasonic bath (5 min) and crystallized in a furnace according to the manufacturer’s instructions. For lithium disilicate, stand-by temperature of 403 ºC followed by 6 min closing time; first firing temperature (T1) of 820 °C - heating rate of 90 °C/min and held for 10 min; second firing temperature (T2) of 840 °C - heating rate of 30 °C/min and held for 7 min. For ZLS, a stand-by temperature of 400 ºC followed by 8 min closing time; firing temperature of 840 ºC - heating rate of 55 ºC/min and held for 8 min.

Wear Simulation

Each sample was scanned (CEREC AC Omnicam, Sirona, São Paulo, SP, Brazil) before the wear simulation, and the stereolithography (STL) file was stored in a CAD system (Romexis, 4.5.0.R, Planmeca). Each three-dimensional (3D) file was numbered according to the representative sample for further evaluation. The scan accuracy was 2.1 micrometers according to the manufacturer. All specimens were then individually embedded in autopolymerizing acrylic resin cylinder, leaving the top of each disc uncovered. Thus, the samples were submitted to the wear simulator (Biocylce V2, Biopdi, São Carlos, SP, Brazil) with 2 mm steatite pistons (magnesium silicate, Ceramica Chiarotti, Jaguariúna, SP, Brazil), which served as analogue to dental enamel antagonist 1515 Ludovichetti, FS; Trindade, FZ; Werner, A; Kleverlaan, CJ; Fonseca, RG. Wear resistance and abrasiveness of CAD-CAM monolithic materials. J Prosthet Dent2018;120:318:e1-318.e8.,1616 Stawarczyk, B; Özcan, M; Schmutz, F; Trottmann, A; Roos, M; Hämmerle, CH. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 2013;71:102-112.,1717 Preis, V; Grumser, K; Schneider-Feyrer, S; Behr, M; Rosentritt, M. Cycledependent in vitro wear performance of dental ceramics after clinical surface treatments. J Mech Behav Biomed Mater 2016;53:49-58.. The wear simulator operates by applying a vertical load on the specimen, sliding horizontally, and then repeating the cycle 1616 Stawarczyk, B; Özcan, M; Schmutz, F; Trottmann, A; Roos, M; Hämmerle, CH. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 2013;71:102-112.. The parameters for this test were as follows: load of 30 N, frequency of 1.7 Hz, sliding distance of 6 mm and 300,000 cycles at room temperature and in distilled water 1616 Stawarczyk, B; Özcan, M; Schmutz, F; Trottmann, A; Roos, M; Hämmerle, CH. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 2013;71:102-112.. Water was used to keep the antagonists wet, remove worn particles, and simulate the wet environment of the oral cavity.

Parametric Wear and Volume Loss Analysis

The volume loss from each disc was measured using an intraoral scanner (CEREC AC Omnicam, Sirona, São Paulo, SP, Brazil). The 3D STL files of the wear facets were collected (Fig. 1A) and superimposed (Fig. 1B) from the baseline using a 3D digital parametric inspection software (GOM Inspect, Braunschweig, Germany) 99 Naumova, EA; Schneider, S; Arnold, WH; Piwowarczyk, A. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists. Materials ( Basel) 2017;10:E244.. This software generated a colorimetric map of each specimen and then aligned the models to detect the geometric changes that illustrate the wear caused by the antagonist (Fig. 1C). Next, the linear reduction of the discs was also detected by aligning the center of STL file of the disc before and after wear by two-dimensionally comparing them 1818 Zandparsa, R; El Huni, RM; Hirayama, H; Johnson, MI. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016;115:230-237.. The data report indicates the ceramic volume loss (%) and defect depth in micrometers (Fig. 2). Data were analyzed by descriptive statistics, one-way analysis of variance and Tukey test with 5% significance.

Figure 1
A-F: Wear parametric analysis and top surface morphology observation. A: Stereolithography file of one representative sample after wear simulation. B: Superimposition of the sample before and after wear simulation. C: Colorimetric map to detect the geometric changes that illustrate the wear caused by the antagonist. SEM micrographic images of the surface defect at D (35×), E (100×) and F (500×).

Figure 2
A: Illustration of the analyzed plane and its observation using the analysis software. B,C,D: Sagittal analysis of the surface defect. SEM micrographic images of the defects in the same view at B (60×), C (100×) and D (500×).

Surface Roughness

After wear test, the specimens’ surface roughness was evaluated with a contact profilometer (SJ-410, Mitutoyo, Tokyo, Japan). Three parallel readings per specimen were performed and Ra and Rz parameters were measured with Gaussian Filter and cut-off wavelength value of 0.8 mm. The parameters’ means of each specimen was then obtained 1010 Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334.. Data were analyzed by descriptive statistics, one-way analysis of variance and Tukey test, all with 5% significance.

Scanning Electron Microscopy (SEM)

Two representative samples after wear simulation were inspected using SEM (Inspect S50, FEI, Czech Republic). The samples were perpendicularly cut in two parts for direct comparison with the 3D model. The specimens were sputter coated with gold for 130 s at 15 mA, creating a 30-nm-thick layer and examined under different standard SEM magnifications operated at 20 KV using secondary electron detection by a single operator 1010 Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334..

Results

Parametric Wear and Volume Loss Analysis

A boxplot of volume loss and wear depth data are summarized in Figure 3. Descriptive statistics are shown in Table 1. One-way ANOVA showed statistically significant differences among the groups considering the ceramic volume loss and wear depth defect length (Table 2).

Table 1
Volume loss (in %), wear depth defect length (µm), minimum and maximum values for lithium disilicate (LD) and zirconia reinforced lithium silicate (ZLS)

Table 2
One-way Analysis of Variance results of volume loss and wear depth defect length according to the ceramic material

Surface Roughness

One-way ANOVA showed that Ra, average surface roughness, (p=0.064) was similar between ZLS (0.25±0.18 μm) and LD (0.29±0.23 μm). While Rz, the high parameter, (p=0.001) showed that LD (3.08±1.02) presented higher mean value than ZLS (1.51±0.90).

Scanning Electron Microscopy (SEM)

According to SEM images, all discs exhibited slight surface scratches along the sliding direction with pitted wear patterns, and large cracks were also observed on wear traces (Fig. 1D-F). These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software (Fig. 2A). The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape (Fig. 2B-D).

Figure 3:
Boxplot graphs of the amount of volume loss (in %) and wear depth defect length (in mm) according to the ceramic material.

Discussion

The results herein demonstrated statistically significant differences among the ceramics volume loss and wear depth defect length. Therefore, the null hypothesis was rejected. Sliding fatigue is widely used in laboratory tests to evaluate the wear resistance of restorative materials 1818 Zandparsa, R; El Huni, RM; Hirayama, H; Johnson, MI. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016;115:230-237.. Despite the limitations in movement, it is a reproducible method that provides a stressed material with superficial microfatigue. Previous studies evaluating the wear resistance of dental ceramics used cuspal tips of molars extracted as antagonists during the cyclic test 1919 Mitov, G; Heintze, SD; Walz, S; Woll, K; Muecklich, F; Pospiech, P. Wear behavior of dental Y-TZP ceramic against natural enamel after different finishing procedures. Dent Mater 2012;28:909-918.,2020 Sripetchdanond, J; Leevailoj, C. Wear of human enamel opposing monolithic zirconia, glass ceramic, and composite resin: an in vitro study. J Prosthet Dent 2014;112:1141-1150.,2121 Amer, R; Kürklü, D; Johnston, W. Effect of simulated mastication on the surface roughness of three ceramic systems. J Prosthet Dent 2015;114:260-265.,2222 Stawarczyk, B; Frevert, K; Ender, A; Roos, M; Sener, B; Wimmer, T. Comparison of four monolithic zirconia materials with conventional ones: Contrast ratio, grain size, four-point flexural strength and two-body wear. J Mech Behav Biomed Mater 2016;59:128-138.. The use of an analogue in steatite was previously validated in the literature as a substitute for dental enamel because it has similar mechanical characteristics 1717 Preis, V; Grumser, K; Schneider-Feyrer, S; Behr, M; Rosentritt, M. Cycledependent in vitro wear performance of dental ceramics after clinical surface treatments. J Mech Behav Biomed Mater 2016;53:49-58., enables better specimen standardization, facilitates reproducibility of the study and also geometry control. Thus, steatite was the material of choice for promoting in vitro wear.

The method used herein was reported in studies that verified the final effect on the geometry of a specimen after mechanical fatigue. Zandparsa et al. 1818 Zandparsa, R; El Huni, RM; Hirayama, H; Johnson, MI. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016;115:230-237. evaluated the dental enamel wear against different restorative materials, verifying the volume loss and the defect depth. The authors did not find a statistically significant difference for the studied effects and still found discrepancies between the verification of volume loss and defect depth generated at the tips of the worn teeth. In contrast, the present study found a significant difference for both analysis parameters between the tested materials. It is worth mentioning that the accuracy of the scanner used is very important for this methodology, because low wear values which are undetectable by the 3D file can suggest a false positive result. Therefore, a scanner with higher accuracy than that previously reported 1818 Zandparsa, R; El Huni, RM; Hirayama, H; Johnson, MI. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016;115:230-237. was used herein.

The 3D measurement of total wear was performed in previous studies using CAD software 2323 Choi, JW; Song, EJ; Shin, JH; Jeong, TS; Huh, JB. In vitro investigation of wear of CAD/CAM polymeric materials against primary Teeth. Materials(Basel) 2017;10:e1410.,2424 Zierden ,K; Acar, J; Rehmann, P; Wöstmann, B. Wear and fracture strength of new ceramic resins for chairside milling. Int J Prosthodont2018;31:74-76.. The innovation in the present study and the study of Zandparsa et al. 1818 Zandparsa, R; El Huni, RM; Hirayama, H; Johnson, MI. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016;115:230-237. is the possibility of measuring the wear depth, as well as the evidence of worn areas in a parametric manner by a computational overlap of previous files and post fatigue through specific software. The overlap in drawing software can be empirical and inaccurate.

Lithium disilicate was more susceptible to wear with greater loss of volume and generated defect depth compared to the zirconia reinforced lithium silicate under the same conditions. The elastic modulus of the restorations is also a factor correlated with the stress concentration on the surface in response to the applied occlusal forces. As the ZLS presents a smaller elastic modulus than the LD, previous studies report lower stress concentration in its structure. Moreover, Dal Piva et al. 22 Dal Piva, AMO; Tribst, JPM; Borges, ALS; Souza, ROAE; Bottino, MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater2018;S0109-5641:30026-30035. define that this material has a lower risk of mechanical failure than the LD, which corroborates the findings of the present study. The direct comparison of the wear resistance between LD and ZLS was previously performed 1111 Matzinger, M; Hahnel, S; Preis, V; Rosentritt, M. Polishing effects and wear performance of chairside CAD/CAM materials. Clin Oral Investig 2019;23:725-737. through evaluating the 3D model in CAD software. Our findings corroborate the findings that ZLS presented lower volume loss (23.6±7.6%) in comparison with LD (30.6±9.9). As the volume measurement is independent of the spatial position of the geometric model, the use of CAD software for this is perfectly applicable. However, a specific overlap parameter must be used in order to verify the defect depth generated by the wear, such as those found in 3D inspection software. Thus, the authors did not find statistical differences for the defect depth among the ceramics, even though a difference in the lost volume was found. Therefore, the present study deviates in showing that the ceramic that lost more volume presented deeper defects 1111 Matzinger, M; Hahnel, S; Preis, V; Rosentritt, M. Polishing effects and wear performance of chairside CAD/CAM materials. Clin Oral Investig 2019;23:725-737.. On the other hand, Lawson et al. 1212 Lawson, NC; Bansal, R; Burgess, JO. Wear, strength, modulus and hardness of CAD/CAM thyrestorative materials. Dent Mater 2016;32:e275-e283. compared the wear of several dental materials submitted to sliding chewing simulation in a similar device to that used in this manuscript. Although LD had approximately 33% more volume loss than ZLS, the authors found no statistical difference between the wear generated for both materials. The authors also report lower elastic modulus and higher hardness for the ZLS, which would justify the smaller volume loss in comparison to the LD. The SEM figure herein (Figs. 1 and 2) corroborates that previous investigation 1212 Lawson, NC; Bansal, R; Burgess, JO. Wear, strength, modulus and hardness of CAD/CAM thyrestorative materials. Dent Mater 2016;32:e275-e283., which showed the same defect pattern generated on the discs’ surface after chewing simulation. It is important to emphasize that this study used 20 specimens and only performed a statistical comparison between two materials instead of n=10 and a comparison of 8 substrates as in the discussed study. Contact profilometry was also applied as a measurement technique for simulated in vitro wear. 99 Naumova, EA; Schneider, S; Arnold, WH; Piwowarczyk, A. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists. Materials ( Basel) 2017;10:E244. The authors compared ZLS with two polymer infiltrated ceramics and found that the substance loss on the crowns were found to be on a comparable level for glass ceramic in the resin interpenetrating matrix and ZLS.

Regarding surface roughness, Matzinger et al. 1111 Matzinger, M; Hahnel, S; Preis, V; Rosentritt, M. Polishing effects and wear performance of chairside CAD/CAM materials. Clin Oral Investig 2019;23:725-737. did not found difference between ZLS and LD using Ra parameter after chewing simulation. Therefore, the results corroborates with those findings for the parameter of average surface defects. When using another roughness parameter, analyzing the difference between the highest peak and deepest vale (Rz) it was possible to point difference between both materials. Rz results corroborates with wear test finding, where the material less strength to resist to the volume loss (LD) was also more susceptible to show higher Rz values.

Ludovichetti et al. 1515 Ludovichetti, FS; Trindade, FZ; Werner, A; Kleverlaan, CJ; Fonseca, RG. Wear resistance and abrasiveness of CAD-CAM monolithic materials. J Prosthet Dent2018;120:318:e1-318.e8. used two-body wear test with ACTA wear machine for 200,000 cycles and determined the wear rate with a surface profilometer. The authors did not found statistically difference between ZLS and LD for wear against bovine enamel. This may have happened due to the absence of cyclic compressive load of this type of test, being the main difference with the method herein.

According to the paper of Elsaka et al. 55 Elsaka, SE; Elnaghy, AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater 2016;32:908-914., ZLS present a homogeneous fine crystalline structure while LD shows a structure with needle-shaped fine-grained crystals embedded in a glassy matrix. Since the microstructure is influenced by the relation between crystalline phase and glassy matrix, any surface or subsurface defect can aggravate wear by fatigue process. Thus, reinforcing the importance a smooth surface to maintain the integrity and texture of the ceramic 2525 Fathy, SM; Swain, MV. In-vitro wear of natural tooth surface opposed with zirconia reinforced lithium silicate glass ceramic after accelerated ageing. Dent Mater 2018;34:551-559.. This can justify the difference in roughness between both tested ceramics, allowing more shear between LD and the antagonist, consequently increasing the wear and volume loss. In spite of the limitations of this study, it is possible to conclude that the zirconia reinforced lithium silicate was more wear resistant than lithium disilicate, with less volume loss throughout the wear simulation and exhibited shallower surface defects.

References

  • 1
    Pieger, S; Salman, A; Bidra, AS. Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review. J Prosthet Dent2014;112:22-30.
  • 2
    Dal Piva, AMO; Tribst, JPM; Borges, ALS; Souza, ROAE; Bottino, MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater2018;S0109-5641:30026-30035.
  • 3
    Tribst, JPM; Dal Piva, AMO; Borges, ALS; Bottino, MA. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis. Rev Odontol UNESP 2018;47:149-154.
  • 4
    Tribst, JPM; Dal Piva, AMO; Madruga, CFL; Valera, MC; Borges, ALS; Bresciani, E; et al. Endocrown restorations: Influence of dental remnant and restorative material on stress distribution. Dent Mater 2018;S0109-5641:31303-31309.
  • 5
    Elsaka, SE; Elnaghy, AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater 2016;32:908-914.
  • 6
    Zimmermann, M; Egli, G; Zaruba, M; Mehl, A. Influence of material thickness on fractural strength of CAD/CAM fabricated ceramic crowns. Dent Mater J2017:29;36:778-783.
  • 7
    Hamza, TA; Sherif, RM. Fracture resistance of monolithic glass-ceramics versus bilayered zirconia-based restorations. J Prosthodont 2019;28:e259-e264.
  • 8
    Sieper, K; Wille, S; Kern, M. Fracture strength of lithium disilicate crowns compared to polymer-infiltrated ceramic-network and zirconia reinforced lithium silicate crowns. J Mech Behav Biomed Mater 2017;74:342-348.
  • 9
    Naumova, EA; Schneider, S; Arnold, WH; Piwowarczyk, A. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists. Materials ( Basel) 2017;10:E244.
  • 10
    Madruga, CFL; Bueno, MG; Dal Piva, AMO; Prochnow, C; Pereira, GKR; Bottino, MA; et al. Sequential usage of diamond bur for CAD/CAM milling: Effect on the roughness, topography and fatigue strength of lithium disilicate glass ceramic. J Mech Behav Biomed Mater 2019;91:326-334.
  • 11
    Matzinger, M; Hahnel, S; Preis, V; Rosentritt, M. Polishing effects and wear performance of chairside CAD/CAM materials. Clin Oral Investig 2019;23:725-737.
  • 12
    Lawson, NC; Bansal, R; Burgess, JO. Wear, strength, modulus and hardness of CAD/CAM thyrestorative materials. Dent Mater 2016;32:e275-e283.
  • 13
    Oh, WS; Delong, R; Anusavice, KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent 2002;87:451-459.
  • 14
    Heintze, SD; Cavalleri, A; Forjanic, M; Zellweger, G; Rousson, V. Wear of ceramic and antagonist--a systematic evaluation of influencing factors in vitro. Dent Mater 2008;24:433-439.
  • 15
    Ludovichetti, FS; Trindade, FZ; Werner, A; Kleverlaan, CJ; Fonseca, RG. Wear resistance and abrasiveness of CAD-CAM monolithic materials. J Prosthet Dent2018;120:318:e1-318.e8.
  • 16
    Stawarczyk, B; Özcan, M; Schmutz, F; Trottmann, A; Roos, M; Hämmerle, CH. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 2013;71:102-112.
  • 17
    Preis, V; Grumser, K; Schneider-Feyrer, S; Behr, M; Rosentritt, M. Cycledependent in vitro wear performance of dental ceramics after clinical surface treatments. J Mech Behav Biomed Mater 2016;53:49-58.
  • 18
    Zandparsa, R; El Huni, RM; Hirayama, H; Johnson, MI. Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016;115:230-237.
  • 19
    Mitov, G; Heintze, SD; Walz, S; Woll, K; Muecklich, F; Pospiech, P. Wear behavior of dental Y-TZP ceramic against natural enamel after different finishing procedures. Dent Mater 2012;28:909-918.
  • 20
    Sripetchdanond, J; Leevailoj, C. Wear of human enamel opposing monolithic zirconia, glass ceramic, and composite resin: an in vitro study. J Prosthet Dent 2014;112:1141-1150.
  • 21
    Amer, R; Kürklü, D; Johnston, W. Effect of simulated mastication on the surface roughness of three ceramic systems. J Prosthet Dent 2015;114:260-265.
  • 22
    Stawarczyk, B; Frevert, K; Ender, A; Roos, M; Sener, B; Wimmer, T. Comparison of four monolithic zirconia materials with conventional ones: Contrast ratio, grain size, four-point flexural strength and two-body wear. J Mech Behav Biomed Mater 2016;59:128-138.
  • 23
    Choi, JW; Song, EJ; Shin, JH; Jeong, TS; Huh, JB. In vitro investigation of wear of CAD/CAM polymeric materials against primary Teeth. Materials(Basel) 2017;10:e1410.
  • 24
    Zierden ,K; Acar, J; Rehmann, P; Wöstmann, B. Wear and fracture strength of new ceramic resins for chairside milling. Int J Prosthodont2018;31:74-76.
  • 25
    Fathy, SM; Swain, MV. In-vitro wear of natural tooth surface opposed with zirconia reinforced lithium silicate glass ceramic after accelerated ageing. Dent Mater 2018;34:551-559.

Publication Dates

  • Publication in this collection
    07 Oct 2019
  • Date of issue
    Sep-Oct 2019

History

  • Received
    11 Jan 2019
  • Accepted
    28 May 2019
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br