Acessibilidade / Reportar erro

Oxygen Inhibition of Surface Composites and Its Correlation with Degree of Conversion and Color Stability

Abstract

This study investigated the effects of oxygen inhibition and finishing/polishing procedures on the composite resin properties. One bulk-fill and two conventional composite resins (nanoparticle and microhybrid) were evaluated. Specimens were prepared using 4 surface treatments: control, no treatment; Gly, oxygen inhibition with glycerin; FP, finishing and polishing; Gly + FP, glycerin followed by finishing and polishing. The degree of conversion (DC) was measured using Fourier Transformed Infrared Spectroscopy (FTIR) immediately and after 15 days (n=5). Color stability (ΔEab, and ΔE00) and opacity were evaluated using a spectrophotometer after 15 days of immersion in coffee, using the CIELAB system (n=5). Data were analyzed by two-way ANOVA and Tukey tests (α=0.05) and opacity by two-way repeated-measures ANOVA. Glycerin usage increased significantly the DC however had no influence on the ΔEab, ΔE00 and, opacity values. Finishing and polishing reduced ΔEab and ΔE00 values, regardless of composite resins. Microhybrid showed higher opacity, followed by the nanoparticle and bulk fill, regardless of surface treatment. Post-polymerization polishing procedures resulted in lower conversion than using an oxygen inhibitor agent (Gly condition), but similar staining caused by coffee.

Key Words:
composite resin; oxygen inhibition; finishing and polishing; color change; degree of conversion

Resumo

Este estudo investigou os efeitos da inibição de oxigênio e dos procedimentos de acabamento/polimento nas propriedades das resinas compostas. Foram avaliadas uma resina composta bulk fill e duas resinas convencionais (nanoparticulada e microhíbrida). Os espécimes foram confeccionados, variando o tratamento de superfície: controle, sem tratamento; glicerina (inibidor de oxigênio); acabamento e polimento; glicerina + acabamento e polimento. O grau de conversão (GC) foi medido pela Espectroscopia de Infravermelho Transformada de Fourier (FTIR) imediatamente e após 15 dias da confecção dos espécimes (n=5). Os índices de alteração de cor ΔEab, ΔE00 e opacidade foram avaliados por meio de espectrofotômetro, após 15 dias de imersão no café, utilizando o sistema CIELAB (n=5). Os dados da alteração da cor foram analisados pelos testes ANOVA de dois fatores e Tukey (α=0,05) e a opacidade por ANOVA de medidas repetidas. O uso de glicerina aumentou significativamente o GC, no entanto, não teve influência sobre os valores ΔEab e ΔE00. O acabamento e o polimento reduziram os valores de ΔEab e ΔE00, independentemente da resina composta. A resina microhíbrida apresentou maior opacidade, seguida pela nanoparticula e bulk-fill, independentemente do tratamento de superfície. O acabamento e polimento resultou em menor grau de conversão das resinas compostas se comparado ao uso de um agente inibidor de oxigênio (glicerina), porém apresenta resultados similares para a pigmentação pelo café.

Introduction

Composite resins are materials widely used in daily practice that need adequate polymerization for good clinical performance 11 Velo MM de AC, Wang L, Furuse AY, Brianezzi LF de F, Scotti CK, Zabeu GS, et al. Influence of modulated photo-activation on shrinkage stress and degree of conversion of bulk-fill composites. Braz Dent J 2019;30:592-598. . These materials are undergoing chemical degradation processes in the oral cavity due to diets that contain staining solutions, as well as acidic foods and drinks 22 Ozera EH, Pascon FM, Correr AB, Puppin-Rontani RM, de Castilho AR, Correr-Sobrinho L, et al. Color stability and gloss of esthetic restorative materials after chemical challenges. Braz Dent J 2019;30:52-57. ,33 Al Kheraif AAA, Qasim SS Bin, Ramakrishnaiah R, Rehman I ur. Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites. Dent Mater J 2013;32:326-331. . Degradation of composite resin, including color alteration, may result in additional costs due to early replacement of restorations. The degree of conversion (DC) of monomers is measured by the percentage of double bonds of carbon consumed during the polymerization reaction 11 Velo MM de AC, Wang L, Furuse AY, Brianezzi LF de F, Scotti CK, Zabeu GS, et al. Influence of modulated photo-activation on shrinkage stress and degree of conversion of bulk-fill composites. Braz Dent J 2019;30:592-598. . The DC depends on the emission spectra of light curing units to match the absorption spectra of the photoinitiators used in these materials. Additionally, the light must actually reach all area of the restoration 44 Soares CJ, Rodrigues MP, Oliveira LRS, Braga SSL, Barcelos LM, Da Silva GR, et al. An evaluation of the light output from 22 contemporary light curing units. Braz Dent J 2017;28:362-371. .

During composite light-curing, the contact of oxygen produces a surface layer of uncured resin 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. ,66 Aromaa MK, Vallittu PK. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin. Dent Mater 2018;34:1247-1252. . The oxygen inhibits the polymerization reaction, resulting in the formation of a polymer chain more prone to staining and wearing 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. . The oxygen-inhibited layer thickness for composite resins ranges from 4 µm to 40 μm 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. . The thickness of the oxygen-inhibited layer depends on the type of monomer, initiator-activator systems, particle morphology, concentration of free radicals, and the oxygen consumption rate 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. ,66 Aromaa MK, Vallittu PK. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin. Dent Mater 2018;34:1247-1252. . Some clinicians have applied glycerin gel or water-soluble gel over the last increment light-curing trough the transparent layer avoiding the oxygen inhibition of composite resin surface 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. ,66 Aromaa MK, Vallittu PK. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin. Dent Mater 2018;34:1247-1252. .

Nowadays, microhybrid and nanoparticle composites are considered universal resin-based restorative materials suitable for the restoration of anterior and posterior teeth due to their excellent aesthetic properties. These nanomaterials use submicrometre particles to further enhance the optical and physical properties of the resins 33 Al Kheraif AAA, Qasim SS Bin, Ramakrishnaiah R, Rehman I ur. Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites. Dent Mater J 2013;32:326-331. . Bulk fill composite resin, flowable and higher viscosity, claim to enable the posterior restoration of build-up in thick layers, 4 to 5 mm, reaching adequate polymerization in deeper regions 44 Soares CJ, Rodrigues MP, Oliveira LRS, Braga SSL, Barcelos LM, Da Silva GR, et al. An evaluation of the light output from 22 contemporary light curing units. Braz Dent J 2017;28:362-371. ,77 Sahadi BO, Price RB, Andre CB, Sebold M, Bermejo GN, Palma-Dibb RG, et al. Multiple-peak and single-peak dental curing lights comparison on the wear resistance of bulk-fill composites. Braz Oral Res 2018;32:e122. ,88 Braga S, Oliveira L, Ribeiro M, Vilela A, da Silva GR, Price RB, et al. Effect of Simulated Pulpal Microcirculation on Temperature When Light Curing Bulk Fill Composites. Oper Dent 2019;44:289-301. ,99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. . Sufficient depth of cure may be achieved by using specific polymerization modulators, by improving the translucency, or by using more potent initiator systems. Restoring posterior cavities using bulk-fill composite resins can result in reduced shrinkage stress and cusp deflection, which might improve the clinical performance of the restoration 1010 Oliveira LRS, Braga SSL, Bicalho AA, Ribeiro MTH, Price RB, Soares CJ. Molar cusp deformation evaluated by micro-CT and enamel crack formation to compare incremental and bulk-filling techniques. J Dent 2018;74:71-78.

To the best of our knowledge, the literature is scarce in terms of the ideal moment to perform surface finishing and polishing procedures of composite resins modulated by presence of unpolymerized monomers on the surface. This condition could absorb pigments, especially on the difficult to access areas such as the proximal surface or occlusal surface of posterior teeth. Moreover, the effects of glycerin use over composite resin surfaces are not clear in relation the mechanical properties improvement. Therefore, the aim of this study was to investigate the effects of oxygen inhibition and finishing/polishing procedures on the degree of conversion (DC) and color stability (ΔEab, ΔE00 and opacity) of bulk-fill and conventional composite resins. The null hypothesis was that the use of the glycerin oxygen inhibitor gel or its association with immediate finishing and polishing would not improve the color stability and the degree of cure of bulk-fill or conventional composite resins.

Material and Methods

Experimental Design

This in vitro investigation was conducted using a 3x4x2 factorial study design to evaluate the factors “composite resin - bulk-fill, conventional nanoparticle and microhybrid”, “protocols of surface treatments- no treatment, oxygen inhibition with glycerin, finishing and polishing, and glycerin + finishing and polishing” and “assessment time - immediate and mediate analysis”. The main response variables included in this study were [1] degree of conversion and [2] color change.

Specimen Preparation

One bulk-fill (Filtek Posterior Bulk-Fill, 3M ESPE, St, Paul, MN, USA), and two conventional nanoparticle (Filtek Z350 XT, 3M ESPE) and microhybrid (Filtek Z250, 3M ESPE) composite resins were evaluated in this study. The compositions of materials used are described in Table 1. To measure the DC, according to the International Standards Organization (ISO) 4049, the composite resins were inserted into a silicone mold (HydroXtreme, Vigodent, Rio de Janeiro, Rio de Janeiro, Brazil) with internal dimensions of 4 mm in diameter x 2 mm of thickness. Specimens for color measurement (ISO/TR 28642) were built-up using a Teflon mold (8 mm of diameter x 2 mm of depth).

Table 1
Materials used (information provided by the manufacturers)

A halogen-light-based curing unit (OptiLux 501, Demetron, Danbury, CT, USA - 600 mW/cm2) was fixed in a standard device in order to maintain a fixed distance between the light-curing tip and sample surface. After placing the material into the mold, a polyester strip was pressed over the surface with a glass slab to obtain a flat surface. After the glass slab and the strip were removed and the photoactivation was made for 20 s, perpendicular and directly on the top of the specimens, at the shortest possible standardized position between the tip and the mold. Specimens were prepared according to different surface treatments:

Control group (Control): the composite resins were light-cured for an additional 20 s.

Glycerin surface treatment (Gly): glycerin (Biopharma, Uberlândia, MG, Brazil) was applied on the surface of composite resin specimens followed by additional light activation for 20 s.

Finishing and polishing (FP): the composite resin specimens were light-cured for an additional 20 s, followed by finishing and polishing with abrasive disc Sof-Lex Pop-On (3M/ESPE) used sequentially according to the abrasiveness (medium, fine, and extra-fine discs). Ten movements were performed for each disc. The surface of the specimen was cleaned with distilled water and the composite resin surface was polished with a polishing paste Fotoacrill (Dhpro, Paranaguá, Paraná, Brazil) associated with a felt disk Diamond (FGM, Joinville, Santa Catarina, Brazil). The felt disk was wiped on the surface of the sample with alcohol 70% (Itajá, Goianésia, Goiás, Brazil) with friction and dried with an air-stream for 10 s following each procedure.

Glycerin + finishing + polishing (Gly + FP): after glycerin surface application and light activation for 20 s, the finishing and polishing were performed using the previously described protocol.

Five specimens were produced with the same finishing/polishing instrument. Before DC analysis, 70% alcohol with gauze was used with on the specimens to remove the glycerin and post polishing compounds. The same clean protocol was used for control group.

Degree of Conversion Measurement

The specimens were placed on the ATR crystal directly with standardized pressure by the ATR device. The DC was measured immediately after the finishing and polishing surface procedures and again after 15 days using Fourier Transformed Infrared Spectroscopy (FTIR- Vertex 70, Bruker Optik GmbH, Ettlingen, Germany). For the evaluation after 15 days, specimens were stored in a dry and dark container at 37 °C. The DC was assessed using FTIR with attenuated total reflectance (ATR crystal) sampling, mid-infrared (MIR) and deuterated triglycine sulfate (DTGS) detector elements (Bruker Optik), with a 4 cm-1 resolution and coaddition of 32 scans. All analyses were performed under controlled temperature (25±1 °C) and humidity (60±5%) conditions. The DC was calculated from the equivalent aliphatic (1640 cm-1) and aromatic (1610 cm-1) of cured (C) and uncured (U) composite resin specimens according to the following equation: DC=(1 - C/U) x 100.

Immersion of Coffee and Color Stability Measurement (N=5)

The color analysis was carried out immediately after specimen preparation. After 24 h of specimens being stored in a dry and dark container at 37 °C, they were individually immersed in 1 mL of coffee solution (Nestlé, São Paulo, SP, Brazil) for 15 days at 37°C 99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. . The solution was replaced daily. After storing, the excess of the solution was removed, and the specimens were ultrasonically (Ultrasonic Cleaner, Thornton - INPEC, Vinhedo, SP, Brazil) washed in distilled water for 10 min and dried.

The readings assessed at baseline were used to calculate the color changes caused by coffee immersion. The baseline color coordinates were assessed in standard conditions by means of a reflectance spectrophotometer (Ci64UV, Xrite, Chandler, Arizona, USA). The device was adjusted for the D65 light source, with 100% ultraviolet and specular reflection included. The observer angle was set at 10 degrees, and the device was adjusted to a small reading area (SAV), with a total area of 4 mm2. The color parameters were measured over white background (L*white 85.6, a*white 1.28, b*white 6.83) while the opacity was directly measured by the device. To measure opacity, samples were made against white, black (L*black 26.32, a*black -38, b*black 0.53), and white backgrounds again 1111 Araujo FS, Barros MCR, Santana MLC, de Jesus Oliveira LS, Silva PFD, Lima G da S, et al. Effects of adhesive used as modeling liquid on the stability of the color and opacity of composites. J Esthet Restor Dent 2018;30:427-433. . The spectrophotometer was adjusted for three consecutive readings, which were later averaged. The opacity was calculated by the contrast ratio from the luminous reflectance (Y) of the specimens with a black (Yb) and a white (Yw) backing. A value of Yb/Yw=0 means that the specimen is completely transparent, and Yb/Yw=100 implies that the specimen is completely opaque.

The results of the color readings were quantified in terms of the L*, a*, and b* coordinate values established by the Commission Internationale de l’Eclairage (CIELAB system). The color difference of the same specimen was calculated by the use of two different equations. The first one is the CIELAB color difference (∆Eab) equation, which was calculated as follows: ΔEab= (ΔL2 + Δa2 + Δb2)1/2 where ∆L*, ∆a*, and ∆b* refers to lightness, green-red, and blue-yellow differences of baseline and post coffee immersion color measurements. The second is the CIEDE2000 color difference (ΔE00), and it was calculated as follows: ΔE00= [(ΔL/KLS + (ΔC/KCSC)2 + (ΔH/KHSH)2 + RT (ΔC/KCSC) (ΔH/KHSH)]½.where ∆L, ∆C and ∆H are considered lightness, chroma, and hue differences between color measurements. KL, KC, and KH are the parametric factors for viewing conditions and illuminating conditions influence. RT is the function for the hue and chroma differences interaction in the blue region. SL, SC, and SH are the weighting functions for the color difference adjustment considering the location variation of L*, a*, and b* coordinates 1212 Miotti LL, Santos IS, Nicoloso GF, Pozzobon RT, Susin AH, Durand LB. The use of resin composite layering technique to mask discolored background: A CIELAB/CIEDE2000 analysis. Oper Dent 2017;42:165-174..

Statistical Analysis

DC data was tested by normal distribution (Shapiro-Wilk test) and homoscedasticity (Levine test) followed by two-way ANOVA and Tukey tests (α=0.05). The color alteration data were tested by normal distribution (Shapiro-Wilk test) and homoscedasticity (Levine test) followed by two-way ANOVA and Tukey tests (α=0.05). For opacity data, two-way repeated measures ANOVA were applied for each composite resin (α=0.05). Linear regression for ∆Eab and immediate and mediate composite DC data set were calculated.

Results

The DC (%) mean and standard deviation values of the all tested composite resins are shown in Table 2. Two-way ANOVA showed that the composite resin (p<0.01) and surface treatment (p<0.01) and the interaction between both study factors (p=0.005) were significant for DC values. The moment of analysis had no influence in the DC values. Glycerin usage increased significantly (p<0.001) the DC values for all composite resins.

Table 2
Mean and standard deviation of the degree of conversion (%) for all composite resins, according to surface treatments and assessment time

The mean and standard deviation values of opacity before and after coffee storage, are shown in Table 3. Two-way ANOVA showed that the composite resin (p=0.007), and moment of analysis (p<0.001) influenced significantly the opacity but not the interaction of them (p=0.803). Microhybrid composite resin showed higher opacity, followed by the nanoparticle and bulk-fill composite resins, regardless of surface treatment.

Table 3
Mean and standard deviation of opacity (%) for all composite resins before and after coffee storage, according to surface treatments

The color changes for L*, a* and b* parameters are shown in Figure 1 and the mean and standard deviation values of ΔEab and ΔE00 after coffee storage, are shown in Table 4. Two-way ANOVA showed that the composite resin (ΔEab: p<0.001/ΔE00:p<0.001) and surface treatment factor (ΔEab:p<0.001/ΔE00:p=0.003) were significant; however, the interactions between both factors (ΔEab:p=0.167/ ΔE00:p=0.38) were not significant. In general, glycerin usage had not influence on the surface coffee staining for all composite resins. Finishing and polishing caused lowest ΔEab and ΔE00 values, regardless of composite resins. Linear regression showed a very weak correlation between ∆E00 and DC (R²=0.00548).

Figure 1
Color changes of composite resins after storage in coffee, according surface treatments. Arepresents the change lightness within a specimen and ranges from 0 (black) to 100 (white). B=represents the change of degree of green/red measurement and C represents the degree of blue/yellow color change of composite resins after the storage in coffee.

Table 4
Means and standard deviation of the color difference (ΔEab and ΔE00) after storage in coffee, according to surface treatments and composite resins

Discussion

In the present study, the DC of bulk-fill and conventional composite resins was affected by the glycerin usage and the color stability was influenced by the finishing and polishing procedures. Therefore, the null hypothesis of this study was rejected.

DC is the proportion of single carbon-carbon bonds in a polymer matrix to double carbon bonds between monomers 11 Velo MM de AC, Wang L, Furuse AY, Brianezzi LF de F, Scotti CK, Zabeu GS, et al. Influence of modulated photo-activation on shrinkage stress and degree of conversion of bulk-fill composites. Braz Dent J 2019;30:592-598. . It has been shown that the clinical performance 1313 Alzraikat H, Burrow MF, Maghaireh GA, Taha NA. Nanofilled resin composite properties and clinical performance: a review. Oper Dent 2018;43:E173-190. of dental composites can be affected by mechanical properties that are influenced mainly by the DC 1414 Oliveira DCRS de, Souza-Junior EJ, Prieto LT, Coppini EK, Maia RR, Paulillo LAMS. Color stability and polymerization behavior of direct esthetic restorations. J Esthet Restor Dent 2014;26:288-295. , filler content and type of matrix 1313 Alzraikat H, Burrow MF, Maghaireh GA, Taha NA. Nanofilled resin composite properties and clinical performance: a review. Oper Dent 2018;43:E173-190. ,1515 Cidreira Boaro LC, Pereira Lopes D, de Souza ASC, Lie Nakano E, Ayala Perez MD, Pfeifer CS, et al. Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis. Dent Mater 2019;35:e249-264. . Low DC values might have negative influence on fracture resistance, wear resistance, compressive strength and can lead to early replacement of long-term restorations caused by detachment or discoloration around the adhesive interfaces 1616 Prieto LT, Pimenta de Araujo CT, Araujo Pierote JJ, Salles de Oliveira DCR, Coppini EK, Sartini Paulillo LAM. Evaluation of degree of conversion and the effect of thermal aging on the color stability of resin cements and flowable composite. J Conserv Dent 2018;21:47-51. . Low DC values can also increase the release of toxic monomers and initiators in the oral environment 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. ,1717 Candea Ciurea A, Surlin P, Stratul S-I, Soanca A, Roman A, Moldovan M, et al. Evaluation of the biocompatibility of resin composite-based dental materials with gingival mesenchymal stromal cells. Microsc Res Tech. 2019;82:1768-1778. . In this study, a higher DC was observed for groups with oxygen inhibition surface treatment by glycerin, regardless of composite resins tested. During polymerization, oxygen reacts rapidly with free oxidized radicals and its presence slows the reaction. Oxygen inhibition improved polymerization of the surface layer 66 Aromaa MK, Vallittu PK. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin. Dent Mater 2018;34:1247-1252. . This aspect could also have impact on the surface hardness when the matrix band for making a direct restoration is removed after the light curing procedure 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. ,66 Aromaa MK, Vallittu PK. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin. Dent Mater 2018;34:1247-1252. .

Low DC was observed in the control group and when composite materials were submitted only to finishing and polishing protocol. Also, these data were lower than the literature reports 33 Al Kheraif AAA, Qasim SS Bin, Ramakrishnaiah R, Rehman I ur. Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites. Dent Mater J 2013;32:326-331. ,11 Velo MM de AC, Wang L, Furuse AY, Brianezzi LF de F, Scotti CK, Zabeu GS, et al. Influence of modulated photo-activation on shrinkage stress and degree of conversion of bulk-fill composites. Braz Dent J 2019;30:592-598. . In this research, one possible explanation for this phenomenon may be related to the fact that a polyester strip was used to obtain a flat surface but it was removed before photoactivation, allowing contact between the resin and oxygen. Additionally, maybe finishing and the polishing protocol was not able to completely remove the unpolymerized resin layer, resulting in a lower DC in the resin composite surface.

However, finishing and polishing 55 Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264. surface procedures can reduce color variation (ΔEab and ΔE00) after immersion in coffee. The esthetic features of restorations should not be defined as a factor indicating some intervention in posterior restorations. However, it is well-known that resin staining remains a cause of re-intervention even in posterior teeth, and more color-stable composites can prevent over-interventions. In case finish and polish procedures are awkward to achieve in posteriors composite restoration, light-curing in the absence of oxygen should be considered, especially when performing composite restoration in esthetic areas or in areas difficult to access such as the proximal surfaces.

Instrumental techniques for measuring color alteration include colorimetry and spectrophotometry, with good reliable performance for dental materials. Spectrophotometry is more accurate than measuring by using colorimeter, which is not influenced by ambient light 22 Ozera EH, Pascon FM, Correr AB, Puppin-Rontani RM, de Castilho AR, Correr-Sobrinho L, et al. Color stability and gloss of esthetic restorative materials after chemical challenges. Braz Dent J 2019;30:52-57. . For the objective color difference measurement in dentistry, the CIELAB color difference formula has been extensively used, allowing for comparison with previous similar studies on dental composites. It assumes the uniformity of CIELAB color space and the equal importance of CIELAB individual parameters (L*, a*, and b*). However, a discrepancy sensitivity on the L*, a*, and b* parameters has been demonstrated concerning visual perceptibility and acceptability thresholds.1212 Miotti LL, Santos IS, Nicoloso GF, Pozzobon RT, Susin AH, Durand LB. The use of resin composite layering technique to mask discolored background: A CIELAB/CIEDE2000 analysis. Oper Dent 2017;42:165-174.,1919 Salgado VE, Rego GF, Schneider LF, Moraes RR, Cavalcante LM. Does translucency influence cure efficiency and color stability of resin-based composites? Dent Mater 2018;34:957-966. . The CIEDE2000 metrics have also been then proposed due better indicative of human visual thresholds, even closer with the adjustment of parametric factor KL, KC, and KH set (2:1:1) 1212 Miotti LL, Santos IS, Nicoloso GF, Pozzobon RT, Susin AH, Durand LB. The use of resin composite layering technique to mask discolored background: A CIELAB/CIEDE2000 analysis. Oper Dent 2017;42:165-174.. Similar results were observed for both color difference parameters in this research.

In the present study, microhybrid composite resin storage for 15 days in coffee had different performance, in terms of color change than conventional nanoparticle or bulk-fill composite resins, regardless of surface treatment. The difference in staining may be attributed to the composition of the materials and the characteristics of the particles. The hydrophilicity and degree of water sorption of a resin matrix could affect the staining susceptibility of resin composites. Although the particle sizes of nanoparticle resin composite smaller than microhybrid, it is expected to show less water sorption, thus less ∆E. The discrepancy could be due to resin matrices and additives such as dyes, photosensitizer molecules, and other chemicals in these materials. Moreover, both bulk-fill and nanoparticle (enamel shade) have high translucency and high-translucent materials had the lowest color stability 1919 Salgado VE, Rego GF, Schneider LF, Moraes RR, Cavalcante LM. Does translucency influence cure efficiency and color stability of resin-based composites? Dent Mater 2018;34:957-966.

The aging process was simulated to examine changes in the color alteration of the composite resins over time 1414 Oliveira DCRS de, Souza-Junior EJ, Prieto LT, Coppini EK, Maia RR, Paulillo LAMS. Color stability and polymerization behavior of direct esthetic restorations. J Esthet Restor Dent 2014;26:288-295. ,1616 Prieto LT, Pimenta de Araujo CT, Araujo Pierote JJ, Salles de Oliveira DCR, Coppini EK, Sartini Paulillo LAM. Evaluation of degree of conversion and the effect of thermal aging on the color stability of resin cements and flowable composite. J Conserv Dent 2018;21:47-51. ,2020 Roselino L de MR, Chinelatti MA, Alandia-Roman CC, Pires-de-Souza F de CP. Effect of brushing time and dentifrice abrasiveness on color change and surface roughness of resin composites. Braz Dent J 2015;26:507-513. . In vitro studies evaluating color stability have examined composite specimens immersed in staining solutions over a particular period of time 99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. ,1414 Oliveira DCRS de, Souza-Junior EJ, Prieto LT, Coppini EK, Maia RR, Paulillo LAMS. Color stability and polymerization behavior of direct esthetic restorations. J Esthet Restor Dent 2014;26:288-295. ,1616 Prieto LT, Pimenta de Araujo CT, Araujo Pierote JJ, Salles de Oliveira DCR, Coppini EK, Sartini Paulillo LAM. Evaluation of degree of conversion and the effect of thermal aging on the color stability of resin cements and flowable composite. J Conserv Dent 2018;21:47-51. . Some beverages can alter the color of composite resins through the absorption and/or adsorption of colorants during the period of exposure 99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. ,2121 Alberton Da Silva V, Alberton Da Silva S, Pecho OE, Bacchi A. Influence of composite type and light irradiance on color stability after immersion in different beverages. J Esthet Restor Dent 2018;30:390-396. . In most studies, the specimens have been immersed in coffee, grape juice, wine, and other beverages continuously for long periods of time (hours or days) 33 Al Kheraif AAA, Qasim SS Bin, Ramakrishnaiah R, Rehman I ur. Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites. Dent Mater J 2013;32:326-331. ,99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. . However, the exposure of composite restorations to beverages in vivo occurs through several cycles of a few seconds each. The temperature of a beverage can also increase its staining effect, as volumetric changes caused by heat or cold affect possible specimen defects 2222 Ren Y-F, Feng L, Serban D, Malmstrom HS. Effects of common beverage colorants on color stability of dental composite resins: the utility of a thermocycling stain challenge model in vitro. J Dent 2012;40:e48-56.

For most restorative materials, there is a complex process in the oral environment that includes disintegration and dissolution in saliva and other types of physical/chemical degradation, such as wear and erosion caused by food and drinks, chewing, and bacterial activity 99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. ,1717 Candea Ciurea A, Surlin P, Stratul S-I, Soanca A, Roman A, Moldovan M, et al. Evaluation of the biocompatibility of resin composite-based dental materials with gingival mesenchymal stromal cells. Microsc Res Tech. 2019;82:1768-1778. . This study demonstrated that bulk-fill composite resin storage for 15 days in coffee had different performance, in terms of opacity, than conventional composite resins, regardless of surface treatment. While there is a less evident change in the chemical composition in bulk-fill and conventional composites, the enhanced depth of cure in several bulk-fill is not a result of an improved refractive index mismatch between resin and filler but seems rather have been carried out by reducing the amount of pigments and enlarging the filler size. The higher level of translucency already characteristic of bulk-fill and nanoparticle resins may be responsible for the lower opacity values ​​than microhybrid resin.

More studies are still necessary, especially clinical trials, with real time follow-up. Additionally, in laboratorial study should perform thermal/mechanical fatigue, wettability, water sorption and solubility, the thickness of the unpolymerized surface layer, biofilm presence for degradation and cumulative deleterious effects, to better respond to the dilemma of long-term maintenance of restorative materials after oxygen inhibition and also the consequence of the finishing and polishing procedures. The degradation can be prolonged by the maintenance of a low pH in the oral cavity 99 Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868. ,2323 Somacal DC, Manfroi FB, Monteiro M, Oliveira SD, Bittencourt HR, Borges GA, et al. Effect of pH cycling followed by simulated toothbrushing on the surface roughness and bacterial adhesion of bulk-fill composite resins. Oper Dent 2020;45:209-218. . Associated with stains produced by immersion in drinks such as coffee, this aspect may also contribute to marginal discoloration, which is wrongly defined as the main reason for the replacement of esthetics restorations 1818 Paravina RD, Ghinea R, Herrera LJ, Bona AD, Igiel C, Linninger M, et al. Color difference thresholds in dentistry. J Esthet Restor Dent 2015;27:S1-9. ,2424 Demarco FF, Collares K, Coelho-de-Souza FH, Correa MB, Cenci MS, Moraes RR, et al. Anterior composite restorations: A systematic review on long-term survival and reasons for failure. Dent Mater 2015;31:1214-24. ,2525 Demarco FF, Correa MB, Cenci MS, Moraes RR, Opdam NJM. Longevity of posterior composite restorations: not only a matter of materials. Dent Mater 2012;28:87-101.

In this study, it was simulated the effect of intermittent usage of coffee on the composite resins. The immersion of coffee negatively influenced the physical and chemical properties of the composite resins tested. To maintain the esthetic performance of composite resin restoration, it is suggested to make finishing and polishing surface procedures after conclude the restorative procedure. It is an important indicator to reduce the possibility of changing color parameters and could prevent degradation and darkening of composite resins. Furthermore, patients should be informed about the deleterious effects caused by the abusive use of coffee solutions on composite resin restorations.

The clinical significance of this study is that the degree of conversion of the composite resins surface can be improved by using glycerin to reduce the oxygen presence and the surface staining can be reduced if this previous procedure is associated with immediate finishing and polishing procedures. Within the limits imposed in the experimental design, it is possible to conclude that the glycerin usage increased the degree of conversion and had no effect on the surface coffee staining of tested composite resins and the finishing and polishing surface procedures reduced significantly the color variation (ΔEab/ ΔE00) on the surface of bulk-fill and conventional composite resins.

Acknowledgments

This study was financed in part by the Coordination of Superior Level Staff Improvement - CAPES /(Finance Code 001) and the Research Supporting Foundation of Minas Gerais State - FAPEMIG (Finance Code 11311).

References

  • 1
    Velo MM de AC, Wang L, Furuse AY, Brianezzi LF de F, Scotti CK, Zabeu GS, et al. Influence of modulated photo-activation on shrinkage stress and degree of conversion of bulk-fill composites. Braz Dent J 2019;30:592-598.
  • 2
    Ozera EH, Pascon FM, Correr AB, Puppin-Rontani RM, de Castilho AR, Correr-Sobrinho L, et al. Color stability and gloss of esthetic restorative materials after chemical challenges. Braz Dent J 2019;30:52-57.
  • 3
    Al Kheraif AAA, Qasim SS Bin, Ramakrishnaiah R, Rehman I ur. Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites. Dent Mater J 2013;32:326-331.
  • 4
    Soares CJ, Rodrigues MP, Oliveira LRS, Braga SSL, Barcelos LM, Da Silva GR, et al. An evaluation of the light output from 22 contemporary light curing units. Braz Dent J 2017;28:362-371.
  • 5
    Marigo L, Nocca G, Fiorenzano G, Calla C, Castagnola R, Cordaro M, et al. Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. Biomed Res Int 2019;2019:4240264.
  • 6
    Aromaa MK, Vallittu PK. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin. Dent Mater 2018;34:1247-1252.
  • 7
    Sahadi BO, Price RB, Andre CB, Sebold M, Bermejo GN, Palma-Dibb RG, et al. Multiple-peak and single-peak dental curing lights comparison on the wear resistance of bulk-fill composites. Braz Oral Res 2018;32:e122.
  • 8
    Braga S, Oliveira L, Ribeiro M, Vilela A, da Silva GR, Price RB, et al. Effect of Simulated Pulpal Microcirculation on Temperature When Light Curing Bulk Fill Composites. Oper Dent 2019;44:289-301.
  • 9
    Borges MG, Soares CJ, Maia TS, Bicalho AA, Barbosa TP, Costa HL, et al. Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins. J Prosthet Dent 2019;121:868.e1-868.e868.
  • 10
    Oliveira LRS, Braga SSL, Bicalho AA, Ribeiro MTH, Price RB, Soares CJ. Molar cusp deformation evaluated by micro-CT and enamel crack formation to compare incremental and bulk-filling techniques. J Dent 2018;74:71-78.
  • 11
    Araujo FS, Barros MCR, Santana MLC, de Jesus Oliveira LS, Silva PFD, Lima G da S, et al. Effects of adhesive used as modeling liquid on the stability of the color and opacity of composites. J Esthet Restor Dent 2018;30:427-433.
  • 12
    Miotti LL, Santos IS, Nicoloso GF, Pozzobon RT, Susin AH, Durand LB. The use of resin composite layering technique to mask discolored background: A CIELAB/CIEDE2000 analysis. Oper Dent 2017;42:165-174.
  • 13
    Alzraikat H, Burrow MF, Maghaireh GA, Taha NA. Nanofilled resin composite properties and clinical performance: a review. Oper Dent 2018;43:E173-190.
  • 14
    Oliveira DCRS de, Souza-Junior EJ, Prieto LT, Coppini EK, Maia RR, Paulillo LAMS. Color stability and polymerization behavior of direct esthetic restorations. J Esthet Restor Dent 2014;26:288-295.
  • 15
    Cidreira Boaro LC, Pereira Lopes D, de Souza ASC, Lie Nakano E, Ayala Perez MD, Pfeifer CS, et al. Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis. Dent Mater 2019;35:e249-264.
  • 16
    Prieto LT, Pimenta de Araujo CT, Araujo Pierote JJ, Salles de Oliveira DCR, Coppini EK, Sartini Paulillo LAM. Evaluation of degree of conversion and the effect of thermal aging on the color stability of resin cements and flowable composite. J Conserv Dent 2018;21:47-51.
  • 17
    Candea Ciurea A, Surlin P, Stratul S-I, Soanca A, Roman A, Moldovan M, et al. Evaluation of the biocompatibility of resin composite-based dental materials with gingival mesenchymal stromal cells. Microsc Res Tech. 2019;82:1768-1778.
  • 18
    Paravina RD, Ghinea R, Herrera LJ, Bona AD, Igiel C, Linninger M, et al. Color difference thresholds in dentistry. J Esthet Restor Dent 2015;27:S1-9.
  • 19
    Salgado VE, Rego GF, Schneider LF, Moraes RR, Cavalcante LM. Does translucency influence cure efficiency and color stability of resin-based composites? Dent Mater 2018;34:957-966.
  • 20
    Roselino L de MR, Chinelatti MA, Alandia-Roman CC, Pires-de-Souza F de CP. Effect of brushing time and dentifrice abrasiveness on color change and surface roughness of resin composites. Braz Dent J 2015;26:507-513.
  • 21
    Alberton Da Silva V, Alberton Da Silva S, Pecho OE, Bacchi A. Influence of composite type and light irradiance on color stability after immersion in different beverages. J Esthet Restor Dent 2018;30:390-396.
  • 22
    Ren Y-F, Feng L, Serban D, Malmstrom HS. Effects of common beverage colorants on color stability of dental composite resins: the utility of a thermocycling stain challenge model in vitro. J Dent 2012;40:e48-56.
  • 23
    Somacal DC, Manfroi FB, Monteiro M, Oliveira SD, Bittencourt HR, Borges GA, et al. Effect of pH cycling followed by simulated toothbrushing on the surface roughness and bacterial adhesion of bulk-fill composite resins. Oper Dent 2020;45:209-218.
  • 24
    Demarco FF, Collares K, Coelho-de-Souza FH, Correa MB, Cenci MS, Moraes RR, et al. Anterior composite restorations: A systematic review on long-term survival and reasons for failure. Dent Mater 2015;31:1214-24.
  • 25
    Demarco FF, Correa MB, Cenci MS, Moraes RR, Opdam NJM. Longevity of posterior composite restorations: not only a matter of materials. Dent Mater 2012;28:87-101.

Publication Dates

  • Publication in this collection
    02 Apr 2021
  • Date of issue
    Jan-Feb 2021

History

  • Received
    07 Aug 2020
  • Accepted
    21 Sept 2020
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br