Acessibilidade / Reportar erro

Heat transfer in porous media

Abstract

In this work, the effects of electrical double layer (EDL) near the solid/ liquid interface, on three dimensional heat transfer characteristic and pressure drop of water flow through a rectangular microchannel numerically are investigated. An additional body force originating from the existence of EDL is considered to modify the conventional Navier-stokes and energy equations. These modified equations are solved numerically for steady laminar flow on the basis of control volume approaches. Fluid velocity distribution and temperature with presence and absence of EDL effects are presented for various geometric cases and different boundary conditions. The results illustrate that, the liquid flow in rectangular microchannels is influenced significantly by the EDL, particularly in the high electric potentials, and hence deviates from flow characteristics described by classical fluid mechanics.

Microchannel; Heat transfer; Pressure drop; EDL


FLUID DYNAMICS, HEAT AND MASS TRANFER AND OTHER TOPICS

Heat transfer in porous media

N. Amanifard; M. Borji; A. K. Haghi* * To whom correspondence should be addressed

School of Engineering, University of Guilan. P.O. Box 3756, Rasht, Iran. E-mail: Haghi@guilan.ac.ir

ABSTRACT

In this work, the effects of electrical double layer (EDL) near the solid/ liquid interface, on three dimensional heat transfer characteristic and pressure drop of water flow through a rectangular microchannel numerically are investigated. An additional body force originating from the existence of EDL is considered to modify the conventional Navier-stokes and energy equations. These modified equations are solved numerically for steady laminar flow on the basis of control volume approaches. Fluid velocity distribution and temperature with presence and absence of EDL effects are presented for various geometric cases and different boundary conditions. The results illustrate that, the liquid flow in rectangular microchannels is influenced significantly by the EDL, particularly in the high electric potentials, and hence deviates from flow characteristics described by classical fluid mechanics.

Keywords: Microchannel; Heat transfer; Pressure drop; EDL.

INTRODUCTION

The development of electronic industry and its trend toward miniaturization and high speed operating processes requires higher performance and small scale cooling systems. Removal of this amount of heat, more than 106w/m2, attracts much attention in resent researches. Many ideas for initiative cooling methods have been proposed including a microchannel heat sink. There is an electrical potential on the sides of microchannels because of substance of them. Furthermore, the fluid is ionized to prevent fouling in microchannels. The interaction between the microchannels electrical potential and the fluid's ions is called the effect of Electric Double Layer. Because of the electrostatic interaction the focalization of the counterions near the solid surfaces is much more than the bulk liquid that is far from these solid surfaces. Hence, exists a very condensed layer of counterions are attracted to solid surfaces, and ions in this layer are immobile. This layer is named the compact layer. The thickness of this layer is about several Angstroms. Between the compact layer and uniform bulk liquid, the compaction of ions gradually reduces to that of bulk liquid. Ions in this region, are influenced less by electrostatic interaction, and are movable. This region is called diffuse layer of the EDL. For macrochannel flow the EDL effects is safely negligible since the thickness of the EDL is very small compared with channel size. But in microchannel that can't be omitted.

Since pioneering work of Tuckerman and Pease (1981) that demonstrated the microchannel heat sinks, consisting of micro- rectangular flow passages, have a higher heat transfer coefficient in laminar flow regime than that in turbulent flow through conventionally-sized devices, and show that the flow rate follows the Poisoil equation; many experimental, analytical and numerical investigations are reported. Peng et. al. (1994) and Peng and Peterson (1996) systematically examined the forced flow and heat transfer characteristics of water and binary mixtures flowing through rectangular microchannels. It was observed that laminar flow transition occurred at Reynolds number between 200 and 700. And the critical transition Reynolds number diminished with the decrease in the size of the microchannel. Furthermore, the effects of aspect ratio and the hydraulic diameter on the flow and heat transfer in microchannel were investigated. These results provided noticeable experimental data and considerable manifestation that the flow and heat transfer in microchannels are strongly dependent upon the type and properties of the working fluid as well as geometric parameters of microchannels, and therefore may be different from what typically occur in the macrochannels (Wang and Peng, 1994). Wilding et.al. (1994) analyzed flow of water and various biological fluids in glass-capped silicon microchannels. The data illustrated an approximately 50% increase in the Darcy friction factor from the theoretical results. Similar results were observed by Jiang et.al. (1995) who studied flow of water through rectangular and trapezoid cross-section channels. The microchannels used in this study were formed by etching a silicon substrate and capping it with a glass wafer. Mala et.al. (1997) presented a paper on a microchannel flow and heat transfer between two parallel plates with electrokinetic effects. More recently, Mala et. al. (1997) reported experimental studies of flow of distilled water and aqueous solutions through silicon and glass microchannels between two parallel plates. Microchannels with a height ranging from 10-280µm were used in their measurements. Their results amply demonstrated that the liquid flow in such a microchannel was strongly influenced by the electrokinetic effects. For example, depending on the channel height and the electrical properties of the channel surface, the measured flow rate of the distilled water can be 80% lower than the predicted from the classical Poiseuille flow equation.

PHYSICAL MODEL AND COMPUTATIONAL DOMAIN

A schematic view, physical, and computational domain of such microchannels is depicted in Figure (1), Figure (2), and Figure (3), respectively. The microchannel has been studied is made of silicon. At the bottom, a uniform heat flux of q" arises from an electric chip that is connected to the microchannel. At the top of the channels, there is a Pyrex plate which makes an adiabatic condition. The width of microchannels and the wall thickness are represented by Wc and Ws, respectively. The thickness of the silicon substrate through which the heat flux is transformed to the cooling fluid flowing in channels can be simply recognized as Ht-Hc, according to Figure (1). The total length and width of microchannels are Lt and Wt whose values of five different cases are in Table (1). Moreover, steady incompressible and laminar fluid flow and steady heat transfer, with negligible radiative heat transfer and constant solid and fluid property have been assumed in computations. The cooling fluid flowing in channels is diluted electrolyte liquefied of Kcl that enters the channels with 20ºC temperature. By using of electrolyte liquid as cooling fluid, we can decrease the deposits. The silicon walls of microchannel will have static electric charge because of connecting to electric chip. A body force originates from the connection of this electric charge and the electrolyte liquid. A microchannel in the center parts of the plate will be considered in current work. As a result of the symmetry of the rectangular channel, we will center the computational domain in a half channel as shown in Figure (3).




THE EDL EQUATION

Most of solid surfaces convey a static electric charge. In other words they will have superficial electric potential. If the liquid contains a very small number of ions (for instance, due to impurity), the electrostatic charges on the non-conducting solid surface will captivate the counterions, and repel similar ions in cooling fluid. Consequently, as we can see in Figure (4), the ions near the solid surface will found a new arrangement. The rearrangement of the charges on the solid surface and the balancing charges in the fluid is called the electric double layer. On the basis of electrostatic theorems, relation between electric potential Y, and net volume charge density re in each point of fluid, is decrypted by Poisson equation as follows:


er, and e0 represent the dielectric constant of the solution and permittivity of vacuum respectively. Assuming the Boltzman distribution equation is applicable, the number concentration of the type-i ion in an electrolyte fluid can be considered as follows:

Where ni0 and zi are the bulk concentration and the valence of type-i ion, respectively, e is the elementary charge, kb is the Boltzman constant, and T is the absolute temperature. This equation is established only when the system is in equilibrium state. The net volume charge density is commensurate to difference between concentration of cations and anions, via

Substitution of equation (3) into equation (1) leads to the conspicuous Poisson-Boltzman equation:

With considering the Debye-Huckel parameter and following dimensionless groups:

Where Dh is hydraulic diameter of the rectangular channel, Y and Z are non-dimensional coordinates. By using above non-dimensionless groups equation (4) can be non-dimensionalized as:

Here K, is the non-dimensional electrokinetic diameter, depicted as the ratio of the hydraulic diameter to the electrical double layer thickness, and is the non-dimensional electrical potential standing for the ratio of the electrical energy zey to the thermal energy kbT. Considering Figure (3) we can issue following boundary conditions:

Where defined by is a non-dimensional zeta potential of the channel walls (here z is the potential of the channel wall). The zeta potential is an electric potential at the channel walls. After solving equation (11) and computing , the net volume charge density can be obtained as follows:

This net volume charge density is needed for computing of body forces originating from EDL.

Modified Navier-Stokes Equations

Assuming a laminar fully developed flow in rectangular channels in positive x-direction, the components of velocity satisfy u = u (y, z) and v = w = 0in terms of Cartesian coordinate. The equation of motion is written as follows:

In this equation the final term at right hand, is the effects of body forces originating from EDL. Considering following dimensionless groups we can obtain the non-dimensional form of equation (14),

Substitution of resent equations in equation (14), the non-dimensional for of this equation can be obtained:

Related boundary conditions are as follows:

After numerical solution of equation (22) the velocity field will be obtained.

Energy Equation

As presented in Figure (1), a silicon wafer plate with a large number of microchannels is connected to the chip. A liquid is forced to flow through these microchannels to remove the heat. All microchannels are assumed to have a uniform rectangular cross-section with geometric parameters as shown in Table (1). For a steady-state, fully developed, laminar flow in a microchannel, the energy equation (with consideration of the axial thermal conduction in flow direction and the viscous dissipation) for the cooling liquid takes the specific form:

Where q and af are the temperature and the thermal diffusivity of the cooling liquid, respectively, Cpf is the specified heat capacity of the cooling liquid. Based on presented computational domain, the adiabatic condition can be used along the channel symmetric center line:

At the bottom of channels, a uniform heat flux of q" is imposed over the heat sink, and can be expressed as:

Hear kf is the thermal conductivity of the liquid coolant. Since the thermal conductivity of the glass is about two-order of magnitude lower than that the top boundary is insulted. This is a conservative assumption which will lead to slight underestimation of the overall heat transfer coefficient. This assumption yields:

NUMERICAL SOLUTION METHOD

In current work finite volume method of Patankar is used to solve the continuity, momentum, and energy equations numerically. Since a detailed discussion of the FVM is available in Patankar (1980), only a very brief description of the main features of this method is given here.

In the FVM, the domain is divided into a number of control volumes such that there is one control volume surrounding each grid point. The grid point is located in the center of a control volume. The governing equation is integrated over each control volume to derive an algebraic equation containing the grid point values of the dependent variable. The discretization equation then expresses the conservation principle for a finite control volume just as the partial differential equation expresses it for an infinitesimal control volume. The resulting solution implied that the integral conservation of quantities such as mass, momentum, and energy is exactly satisfied for any control volume and of course, for the whole domain. The power-low scheme is used to model the combined convection-diffusion effects in the transport equations. The SIMPLER algebraic of Patankar is used to resolve the pressure-velocity coupling. The resulting algebraic equations are solved using a line-by-line Tri-Diagonal matrix Algorithm.

RESULTS AND DISCUSSIONS

The samples that have been considered in this article and their results are depicted in Table (2). Toh et. al. (2002) presents results without considering EDL for distances 1-4. They compared heir results with experimental results of Tuckermann (1984) . The thermal resistance was the basis of their comparisons, in the same way for verification of results in this study; the experimental results of Tuckermann are used. The thermal resistance is defined as follows:

In equation (28), Tout and Tin represent the measured outlet and inlet temperature of cooling water, respectively, and q is the heat flux.

The numerically obtained results are compared with those of experimental results conducted by Toh et. al. (2002), and Tuckermann (1984) and presented in Table (2). It is shown that sufficiently reasonable agreement exists in such comparison. The thermal resistance due to decrease of volumetric flow rate and consequently increase of Tout increases from case 1 to case 4.

For considering of effects of EDL, the gradient of pressure, velocity profile, and temperature profile are inspected for both, existing of EDL with two amounts for zeta potential, 75 milivolt and 200 milivolt, and absence of EDL. The 75 milivolt zeta potential is considered for feeble EDL effects, and 200 milivolt zeta potential is selected for strong EDL effects. The effects of EDL on distribution of pressure along the microchannel are showed in Figure (5) for case1. The percentage of effects of EDL on dimensionless distribution of pressure for case 1 to case 4 is presented in Table (3). The illustrated difference in alterations of pressure affected of EDL is because of coming into existence of apparent viscosity that is much more than viscosity in absence of EDL. As it can be seen in Table (3), the percentage of alterations of pressure in 75 milivolt zeta potential for cases 1-4 is not so intense, but in 200 milivolt zeta potential for case 0 that has minimum channel width, exists a large mutation causes to considerable thickness of EDL with respect to channel width. Hence we can conclude that whit increasing of thickness of EDL in comparison with channel width the effects of EDL will be stronger. Pressure drop considerations will determine the required pumping power. The more pressure drop, the more required pumping power. Thus, with existing of a powerful EDL effect, we will require much pumping power, and this is not so suitable. The effects of EDL on velocity profile are depicted in Figure's (6, 7) for case 0, and case 1 respectively, and percentage of alterations of velocity for cases 1-4 is shown in Table (4). As presented in Table (4), a large mutation in velocity alliteration exists for case 0 in 200 milivolt zeta potential as there is for pressure alliteration in this case. Adhesiveness of ions to channels walls and body forces originated from EDL causes to reducing of volumetric flow rate. Decreasing in characteristic length of microchannel, and increasing in body forces originating from EDL causes to increasing in velocity alliteration. The EDL effects on dimensionless temperature profile with respect to dimensionless channel high are presented for cases 3, 4 in Figure's (8, 9). As illustrated in Figure's (8, 9), temperature of cooling fluid decreases from bottom wall that is exposed to uniform heat flux to top of the channel that is adiabatic. Gradient of temperature near the upper wall of channel depicted that there is not any heat transfer near this wall. Percentage of effects of EDL on dimensionless temperature profile is shown for cases 0-4 in Table (5). As it can be seen in this table presence of EDL causes to increasing of temperature of fluid, particularly in case 0, this increasing can be explained by decreasing of volumetric flow rate. Increasing of temperature of fluid illustrates the low amount of Nusselt number, and this phenomenon deducts the capability of microchannel.




CONCLUSION

The effects of the EDL at the solid/liquid interface on liquid flow and heat transfer characteristics through a rectangular microchannel numerically investigated. A two dimensional Poisson-Boltzman equation governing the electrical potential distribution in the cross section of rectangular microchannels has been solved based on the Debye-Huckel approximation. We can say that; considering the effects of EDL is very necessary for exact solution of equations of motion in electrolyte fluid flow. Because of using of ionized liquid in practical manners, the effects of EDL are not negligible. For the cases that characteristic length of microchannel is comparable with the thickness of EDL or exist a high electric potential, the liquid flow and heat transfer characteristics are significantly affected by the presence of the EDL, and omission of the effects of EDL causes to a much deviates from the prediction of conventional theorems. Presence of EDL causes to an apparent viscosity that is much more than the viscosity of fluid, and increasing of zeta potential also causes to decreasing in volumetric flow rate. Similarly, presence of EDL leading to a large amount of pressure drop in microchannel heat sinks. As a result we can say that, existence of EDL causes to decreasing in efficiency of microchannel.

NOMENCLATURE

Cpf

Specified heat capacity of the cooling liquid

[j kg-1 k-1]

Dh Hydraulic diameter

[m]

e

Elementary charge

[C]

Ex Streaming potential

[v/m]

Non-dimensional Streaming potential Non-dimensional parameter Ht Height of microchannel

[m]

Hc Depth of microchannel

[m]

k Non-dimensional electrokinetic diameter

(-)

kb Boltzman constant

[j mol-1 k-1]

kf

Thermal conductivity of cooling liquid

[w m-1 k-1]

Lt Total length of microchannel

[m]

nio

Bulk concentration of type-I ion

[m-3]

Non-dimensional pressure

(-)

q" Heat flux

[w m-2]

R Thermal resistance

[m2 k w-1]

Re Reynolds number T Absolute temperature

[k]

Tout Measured outlet temperature

[k]

Tin Measured inlet temperature

[k]

u Velocity in X-direction

[ms-1]

v Velocity in Y-direction

[ms-1]

w

Velocity in Z-direction]

[ms-1]

Non-dimensional Velocity in X-direction

(-)

Wc Width of microchannel

[m]

Ws

Wall thickness of microchannel

[m]

Wt Total width of microchannel

[m]

Y Non-dimensional coordinate

(-)

Z Non-dimensional coordinate

(-)

Zi Valence of type-i ion

(-)

Greek Letters

af Thermal diffusivity of the cooling liquid

[wkm2]

er Dielectric constant of the liquid

(-)

e0 Permittivity of vacuum

[CV-1m-1]

q Temperature of cooling liquid

[k]

À Debye-Huckel parameter

[m-1]

z Zeta potential

[V]

Non-Dimensional zeta potential

(-)

rf Density of cooling liquid

[kg m-3]

re Net volume charge density

[C m-3]

y Electric potential

[V]

Y Non-Dimensional Electric potential

(-)

(Received: August 5, 2006 ; Accepted: April 2, 2007)

  • Jiang, X. N., Zhou, Z.Y., Yao, J., Y. Li, and Ye, X. Y., Micro-fluid Flow in Microchannel, In proc. Transdueers 95, Stockholm, Sweden, June 25-29, pp. 317-320, (1995).
  • Mala, G. M., Li, D., and Dale, J. D., Heat Transfer and Fluid Flow in Microchannel, International Journal of Heat and Mass transfer 40 pp. 3079-3088(1997).
  • Mala, G. M., Li, D., Werner, C., Jacobasch, H. J., Ning, Y. B., Flow Characteristics of Water through a Microchannel between TwoParallel Plates with Electrokinetic Effects, International Journal of Heat and Mass transfer 18, pp. 489-496(1997).
  • Patankar, S.V., Numerical Heat Transfer and Fluid Flow, Hemisphere, New York, 1980.
  • Peng, X.F., Peterson, G.P., and Wang, B.X., Heat Transfer Characteristics of Water Flowing through Microchannels, Experimental Heat transfer 7,pp 265-283 (1994).
  • Peng, X.F., and Peterson, G.P., Forced convection Heat Transfer of Single-Phase Binary Mixture through Microchannels. Experimental Thermal and fluid science 12 pp 98-104(1996).
  • Toh, K.C., Chen, X.Y., and Chai, J.C., Numerical Computation of Fluid Flow and Heat Transfer in Microchannels, International Journal of Heat and Mass Transfer 45, pp. 5133_5141(2002).
  • Tuckerman, D.B., Heat Transfer Microstructures for Integrated Circuits, Ph.D. thesis, Stanford University, (1984).
  • Tuckermann, D.B., and Pease, R.F.W., High-performance Heat Sinking for VLSI, IEEE Electron. Dev.Lett.EDL-2, pp. 126-129 (1981).
  • Wang, B.X., and Peng, X.F., Experimental Investigation on Liquid Forced Convection Heat Transfer through Microchannels, International Journal of Heat and Mass Transfer 37 (supple.1), pp 73-82(1994).
  • Wilding, P., Shoffner, M. A., Kircka, and L. J., Manipulation and Flow of Biological Fluids in Straight Channels Micromachined in Silicon, Clin. Chem., vol. 40, pp. 43-47, (1994).
  • *
    To whom correspondence should be addressed
  • Publication Dates

    • Publication in this collection
      23 July 2007
    • Date of issue
      June 2007

    History

    • Accepted
      02 Apr 2007
    • Received
      05 Aug 2006
    Brazilian Society of Chemical Engineering Rua Líbero Badaró, 152 , 11. and., 01008-903 São Paulo SP Brazil, Tel.: +55 11 3107-8747, Fax.: +55 11 3104-4649, Fax: +55 11 3104-4649 - São Paulo - SP - Brazil