Fire risk map for the Serra de São Domingos Municipal Park, Poços de Caldas, MG

Zoneamento de risco de incêndios para o parque municipal da Serra de São Domingos, Poços de Caldas, MG

Abstracts

This study constructed a fire risk map for the Serra de São Domingos Municipal Park (SSDMP), southern Minas GeraisSate, Brazil, which harbors Atlantic Forest remnants and endangered species. Geo-processing techniques were used for producing a preliminary risk map for altimetry (a), land slope (e), slope orientation (d), land-use/cover (u) and influence of roads and buildings (i). After, the risk maps were overlaid to produce a structural fire index (SFI)-based risk map for the Park. The SFI was calculated by using the formula SFI = 0,35i + 0,30u + 0,15d + 0,10a + 0,10e. The risks classes were classified as low (0.0-0.9), moderate (1.0 1.9), high (2.0-2.9), very high (3.0-3.9) and extreme (4.0-5.0). All data were processed with 2.5 m base spatial resolution by using the ArcView GIS. According to the SFI calculated, the SSMP area can be divided into the following fire risk zones: Low (0.93%), Moderate (61.77%), High (31.32%), Very High (4.79%) and Extreme (1.19%). The main risk factor is due to the influence of roads and buildings and most fires start due to anthropogenic causes. The low and moderate risk classes comprehend most of the rainforest area. Clearings and grasslands fit mainly the High risk class. The most vulnerable area of SSDMP was the Northern area bordering pasture, crops and eucalypt fields. The SFI map can be a valuable tool for elaborating a fire prevention plan in a small conservation unit when few climate and fire occurrence data are available.

Atlantic Forest; conservation unit; fire prevention; on-the-screen visual image interpretation


Objetivou-se, com este estudo, produzir um mapa de risco de incêndio para o Parque Municipal da Serra de São Domingos (PMSSD), sul de Minas Gerais, Brasil, que abriga remanescentes de Mata Atlântica e espécies ameaçadas de extinção. Técnicas de Geoprocessamento foram utilizadas para produzir mapas de risco preliminares para altimetria (a), declividade do terreno (e), uso e cobertura do solo (u), orientação de encosta (d) e influência de estradas e construções (i). Os mapas foram integrados, gerando um mapa baseado no índice estrutural de risco de incêndio (SFI) calculado pela fórmula SFI = 0,35i + 0,30u + 0,15d + 0,10a + 0,10e. As classes de risco foram definidas como Baixo (0,0-0,9), Moderado (1,0-1,9), Alto (2,0-2,9), Muito Alto (3,0-3,9) e Extremo (4,0-5,0). Os dados foram trabalhados com resolução espacial de 2,5 m utilizando-se o ArcView SIG. A área do PMSSD pode ser distribuída nas seguintes classes: Baixo (0,93%), Moderado (61,77%), Alto (31,32%), Muito Alto (4,79%) e Extremo (1,19%). O principal fator de risco é a influência de estradas. As classes de risco Baixo e Moderado abrangem a maior parte da cobertura florestal. Clareiras e pastagens ocupam principalmente a classe de risco Alto. A área mais vulnerável do SSDMP é a sua fronteira com pastagens e plantios de café e eucalipto ao norte. O mapa baseado no SFI pode ser um valioso subsídio para a elaboração do plano de prevenção de incêndio de pequenas unidades de conservação com poucos dados relativos ao clima e ao histórico de ocorrência de incêndio disponíveis.

Classificação visual criteriosa; Mata Atlântica; prevenção de incêndio; unidade de conservação


Fire risk map for the Serra de São Domingos Municipal Park, Poços de Caldas, MG

Zoneamento de risco de incêndios para o parque municipal da Serra de São Domingos, Poços de Caldas, MG

Henrique Nery CiprianiI; José Aldo Alves PereiraII; Rossi Allan SilvaIII; Sávio Gouvêa de FreitasIV; Luciano Teixeira de OliveiraV

IForest Engineer, Masters student in Soil and Plant Nutrition - Universidade Federal de Viçosa/UFV - Av. Peter Henry Holfs, s/n - Campus Universitário - Viçosa, MG, Brasil - 36570-000 - hncipriani@hotmail.com

IIForest Engineer, Lecturer D.Sc. in Ecology - Departamento de Ciências Florestais - Universidade Federal de Lavras/UFLA - Cx.P. 3037 - 37200-000 - Lavras, MG, Brasil - j.aldo@dcf.ufla.br

IIIForest Engineer, Masters student in Forest Engineering - Departamento de Ciências Florestais - Universidade Federal de Lavras/UFLA - Cx.P. 3037 - 37200-000 - Lavras, MG, Brasil - rossiallan@gmail.com

IVForest Engineer - Instituto Estadual de Florestas/IEF - Rua Misericórdia, 798, Centro - Oliveira, MG, Brasil - 35540-000 - saviogouvea@hotmail.com

VForest Engineer, Doctoral student in Forest Engineering - Departamento de Ciências Florestais - Universidade Federal de Lavras/UFLA - Cx.P. 3037 - 37200-000 - Lavras, MG, Brasil - oliveiralt@hotmail.com

ABSTRACT

This study constructed a fire risk map for the Serra de São Domingos Municipal Park (SSDMP), southern Minas GeraisSate, Brazil, which harbors Atlantic Forest remnants and endangered species. Geo-processing techniques were used for producing a preliminary risk map for altimetry (a), land slope (e), slope orientation (d), land-use/cover (u) and influence of roads and buildings (i). After, the risk maps were overlaid to produce a structural fire index (SFI)-based risk map for the Park. The SFI was calculated by using the formula SFI = 0,35i + 0,30u + 0,15d + 0,10a + 0,10e. The risks classes were classified as low (0.0-0.9), moderate (1.0 1.9), high (2.0-2.9), very high (3.0-3.9) and extreme (4.0-5.0). All data were processed with 2.5 m base spatial resolution by using the ArcView GIS. According to the SFI calculated, the SSMP area can be divided into the following fire risk zones: Low (0.93%), Moderate (61.77%), High (31.32%), Very High (4.79%) and Extreme (1.19%). The main risk factor is due to the influence of roads and buildings and most fires start due to anthropogenic causes. The low and moderate risk classes comprehend most of the rainforest area. Clearings and grasslands fit mainly the High risk class. The most vulnerable area of SSDMP was the Northern area bordering pasture, crops and eucalypt fields. The SFI map can be a valuable tool for elaborating a fire prevention plan in a small conservation unit when few climate and fire occurrence data are available.

Key words: Atlantic Forest, conservation unit, fire prevention, on-the-screen visual image interpretation.

RESUMO

Objetivou-se, com este estudo, produzir um mapa de risco de incêndio para o Parque Municipal da Serra de São Domingos (PMSSD), sul de Minas Gerais, Brasil, que abriga remanescentes de Mata Atlântica e espécies ameaçadas de extinção. Técnicas de Geoprocessamento foram utilizadas para produzir mapas de risco preliminares para altimetria (a), declividade do terreno (e), uso e cobertura do solo (u), orientação de encosta (d) e influência de estradas e construções (i). Os mapas foram integrados, gerando um mapa baseado no índice estrutural de risco de incêndio (SFI) calculado pela fórmula SFI = 0,35i + 0,30u + 0,15d + 0,10a + 0,10e. As classes de risco foram definidas como Baixo (0,0-0,9), Moderado (1,0-1,9), Alto (2,0-2,9), Muito Alto (3,0-3,9) e Extremo (4,0-5,0). Os dados foram trabalhados com resolução espacial de 2,5 m utilizando-se o ArcView SIG. A área do PMSSD pode ser distribuída nas seguintes classes: Baixo (0,93%), Moderado (61,77%), Alto (31,32%), Muito Alto (4,79%) e Extremo (1,19%). O principal fator de risco é a influência de estradas. As classes de risco Baixo e Moderado abrangem a maior parte da cobertura florestal. Clareiras e pastagens ocupam principalmente a classe de risco Alto. A área mais vulnerável do SSDMP é a sua fronteira com pastagens e plantios de café e eucalipto ao norte. O mapa baseado no SFI pode ser um valioso subsídio para a elaboração do plano de prevenção de incêndio de pequenas unidades de conservação com poucos dados relativos ao clima e ao histórico de ocorrência de incêndio disponíveis.

Palavras-chave: Classificação visual criteriosa, Mata Atlântica, prevenção de incêndio, unidade de conservação.

Full text available only in PDF format.

Texto completo disponível apenas em PDF.

5 ACKNOWLEDGEMENTS

The authors thank the Poços de Caldas authorities and workers that provided assistance throughout the carrying out of this research: Corpo de Bombeiros,Guarda Verde,Guarda Municpal and Departamento de Proteção Ambiental. The fruitful comments from the anonymous revisers are also greatly acknowledged.

This work was financed by the Poços de Caldas City Hall in cooperation with Fundação de Desenvolvimento Científico e Cultural (FUNDECC).

6 REFERENCES

(received: December 3, 2009; accepted: November 30, 2010)

  • BRASIL. Lei n. 9.985, de 18 de julho de 2000. Regulamenta o art. 225, §1º, incisos I, II, III e VII da Constituição Federal, institui o Sistema Nacional de Unidades de Conservação da Natureza e dá outras providências. Brasília: Congresso Nacional, 2000. 23 p.
  • CHUVIECO, E.; CONGALTON, R. G. Application of remote sensing and geographic information systems to forest fire hazard mapping. Remote Sensing of Environment, New York, v. 29, p. 147-159, 1989.
  • CHUVIECO, E. et al. Development of a framework for fire risk assessment using remote sensing and geographic information system technologies. Ecological Modelling, v. 221, p. 46-58, 2010.
  • DALCUMUNE, M. A. B.; SANTOS, A. R. Mapeamento de índice de risco de incêndio para a Região da Grande Vitória/ES, utilizando imagens do satélite LANDSAT para o ano de 2002. In: SIMPóSIO BRASILEIRO DE SENSORIAMENTO REMOTO, 12., 2005, Goiânia. Anais.. Goiânia: INPE, 2005. p. 1485-1492.
  • FERNANDES, M. R. et al. Poços de Caldas: caracterização de ecossistemas. Belo Horizonte: EMATER-MG, 2003. 56 p.
  • FERRAZ, S. F. B.; VETTORAZZI, C. A. Mapeamento de risco de incêndios florestais por meio de sistema de informações geográficas (SIG). Scientia Forestalis, Piracicaba, v. 53, p. 39-48, 1998.
  • FREIRE, S.; CARRÃO, H.; CAETANO, M. R. Produção de cartografia de risco de incêndio florestal com recurso a imagens de satélite e dados auxiliares. 2002. Available in: <http://www.igeo.pt/gdr/pdf/Freire2002.pdf>. Access in: 8 July 2010.
  • HERNANDEZ-LEAL, P. A.; ARBELO, M.; GONZALEZ-CALVO, A. Fire risk assessment using satellite data. Advances in space research, v. 37, p. 741-746, 2006.
  • NÚÑEZ-REGUEIRA, L.; PROUPÍN-CASTIÑEIRAS, J.; RODRÍGUEZ-AÑÓN, J. A. Design of risk index maps as a tool to prevent forest fires in the hill-side zone of Galicia (NW Spain). Bioresource technology, v. 73, p. 123-131, 2000.
  • OLIVEIRA, D. dos S. de et al. Zoneamento de risco de incêndios florestais para o estado do Paraná. Floresta, Curitiba, v. 34, n. 2, p. 217-221, 2004.
  • RIBEIRO, L.; KOPROSKI, L. P.; STOLLE, L.; LINGNAU, C.; SOARES, R. V.; BATISTA, A. C. Zoneamento de riscos de incêndios florestais para a fazenda experimental do Canguiri, Pinhais (PR). Floresta, Curitiba, v. 38, n. 3, 2008.
  • SALAS, J.; CHUVIECO, E. Geographic information systems for wildland fire risk mapping. Wildfire, v. 3, n. 2, p. 7-13, 1994.
  • SANT'ANNA, C. de M.; PEREIRA, J. A. A.; BORÉM, R. A. T. Prevenção e combate a incêndios florestais. Lavras: UFLA/FAEPE, 2001. 88 p.
  • SOARES, R. V. Incêndios florestais: controle e uso do fogo. Curitiba: FUPEF, 1985. 213 p.
  • SOARES, R. V.; BATISTA, A. C. Incêndios florestais: controle, efeitos e uso do fogo. Curitiba, 2007. 264 p.
  • SOUZA, M. P. et al. Zoneamento ambiental do município de poços de Caldas (MG): subsídios ao planejamento territorial. Poços de Caldas: EMATER-MG, 2007. 41 p.

Publication Dates

  • Publication in this collection
    22 Sept 2014
  • Date of issue
    Mar 2011

History

  • Received
    03 Dec 2009
  • Accepted
    30 Nov 2010
UFLA - Universidade Federal de Lavras Universidade Federal de Lavras - Departamento de Ciências Florestais - Cx. P. 3037, 37200-000 Lavras - MG Brasil, Tel.: (55 35) 3829-1706, Fax: (55 35) 3829-1411 - Lavras - MG - Brazil
E-mail: cerne@dcf.ufla.br