Acessibilidade / Reportar erro

Effects of chest wall compression on expiratory flow rates in patients with chronic obstructive pulmonary disease

Abstract

Background:

Manual chest wall compression (CWC) during expiration is a technique for removing airway secretions in patients with respiratory disorders. However, there have been no reports about the physiological effects of CWC in patients with chronic obstructive pulmonary disease (COPD).

Objective:

To compare the effects of CWC on expiratory flow rates in patients with COPD and asymptomatic controls.

Method:

Fourteen subjects were recruited from among patients with COPD who were receiving pulmonary rehabilitation at the University Hospital (COPD group). Fourteen age-matched healthy subjects were also consecutively recruited from the local community (Healthy control group). Airflow and lung volume changes were measured continuously with the subjects lying in supine position during 1 minute of quiet breathing (QB) and during 1 minute of CWC by a physical therapist.

Results:

During CWC, both the COPD group and the healthy control group showed significantly higher peak expiratory flow rates (PEFRs) than during QB (mean difference for COPD group 0.14 L/sec, 95% confidence interval (CI) 0.04 to 0.24, p<0.01, mean difference for healthy control group 0.39 L/sec, 95% CI 0.25 to 0.57, p<0.01). In the between-group comparisons, PEFR was significantly higher in the healthy control group than in the COPD group (-0.25 L/sec, 95% CI -0.43 to -0.07, p<0.01). However, the expiratory flow rates at the lung volume at the PEFR during QB and at 50% and 25% of tidal volume during QB increased in the healthy control group (mean difference for healthy control group 0.31 L/sec, 95% CI 0.15 to 0.47, p<0.01: 0.31 L/sec, 95% CI 0.15 to 0.47, p<0.01: 0.27 L/sec, 95% CI 0.13 to 0.41, p<0.01, respectively) but not in the COPD group (0.05 L/sec, 95% CI -0.01 to 0.12: -0.01 L/sec, 95% CI -0.11 to 0.08: 0.02 L/sec, 95% CI -0.05 to 0.90) with the application of CWC.

Conclusion:

The effects of chest wall compression on expiratory flow rates was different between COPD patients and asymptomatic controls.

physical therapy modalities; chronic obstructive pulmonary disease; peak expiratory flow rate


Clinical Trials Identifier: NCT00981734

BULLET POINTS

  • We compared the effects of CWC on expiratory flow rates in patients with COPD and asymptomatic controls.

  • It was confirmed that PEFR increased during CWC in COPD patients; however, PEFR changes during CWC were lower in COPD patients than in healthy subjects.

  • Although CWC appears to be less effective in increasing absolute expiratory flow rates in COPD patients than in healthy subjects, the PEFR, which is more effective for removing secretions, did increase in the COPD group.

Introduction

Manual chest wall compression (CWC) during expiration is a technique for removing airway secretions11. Branson RD. Secretion management in the mechanically ventilated patient. Respir Care. 2007;52(10):1328-42, discussion 1342-7. PMid:17894902.,22. Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149.. It is known that the main physiological mechanism for removing secretions is increased expiratory flow rates due to increased pleural pressure33. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...

4. McCarren B, Alison JA, Herbert RD. Manual vibration increases expiratory flow rate via increased intrapleural pressure in healthy adults: an experimental study. Aust J Physiother. 2006;52(4):267-71. http://dx.doi.org/10.1016/S0004-9514(06)70006-X. PMid:17132121.
http://dx.doi.org/10.1016/S0004-9514(06)...
-55. McCarren B, Alison JA, Herbert RD. Vibration and its effect on the respiratory system. Aust J Physiother. 2006;52(1):39-43. http://dx.doi.org/10.1016/S0004-9514(06)70060-5. PMid:16515421.
http://dx.doi.org/10.1016/S0004-9514(06)...
and stretching of intercostal muscles by means of manual thoracic compression applied during exhalation66. Guimarães FS, Lopes AJ, Constantino SS, Lima JC, Canuto P, Menezes SL. Expiratory rib cage compression, secretion clearance and respiratory mechanics in mechanically ventilated patients: A randomized crossover trial. Respir Care. 2014;59(5):678-85. http://dx.doi.org/10.4187/respcare.02587. PMid:24106324.
http://dx.doi.org/10.4187/respcare.02587...
. Several studies have also shown that CWC increased expiratory flow rates, improved removal of airway secretions, and improved gas exchange and pulmonary mechanics22. Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149.,66. Guimarães FS, Lopes AJ, Constantino SS, Lima JC, Canuto P, Menezes SL. Expiratory rib cage compression, secretion clearance and respiratory mechanics in mechanically ventilated patients: A randomized crossover trial. Respir Care. 2014;59(5):678-85. http://dx.doi.org/10.4187/respcare.02587. PMid:24106324.
http://dx.doi.org/10.4187/respcare.02587...

7. Genc A, Akan M, Gunerli A. The effects of manual hyperinflation with or without rib-cage compression in mechanically ventilated patients. Italian Journal of Physiotherapy. 2011;1(2):48-54.
-88. Martí JD, Li Bassi G, Rigol M, Saucedo L, Ranzani OT, Esperatti M, et al. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation. Crit Care Med. 2013;41(3):850-6. http://dx.doi.org/10.1097/CCM.0b013e3182711b52. PMid:23314585.
http://dx.doi.org/10.1097/CCM.0b013e3182...
in patients on mechanical ventilation66. Guimarães FS, Lopes AJ, Constantino SS, Lima JC, Canuto P, Menezes SL. Expiratory rib cage compression, secretion clearance and respiratory mechanics in mechanically ventilated patients: A randomized crossover trial. Respir Care. 2014;59(5):678-85. http://dx.doi.org/10.4187/respcare.02587. PMid:24106324.
http://dx.doi.org/10.4187/respcare.02587...

7. Genc A, Akan M, Gunerli A. The effects of manual hyperinflation with or without rib-cage compression in mechanically ventilated patients. Italian Journal of Physiotherapy. 2011;1(2):48-54.

8. Martí JD, Li Bassi G, Rigol M, Saucedo L, Ranzani OT, Esperatti M, et al. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation. Crit Care Med. 2013;41(3):850-6. http://dx.doi.org/10.1097/CCM.0b013e3182711b52. PMid:23314585.
http://dx.doi.org/10.1097/CCM.0b013e3182...

9. MacLean D, Drummond G, Macpherson C, McLaren G, Prescott R. Maximum expiratory airflow during chest physiotherapy on ventilated patients before and after the application of an abdominal binder. Intensive Care Med. 1989;15(6):396-9. http://dx.doi.org/10.1007/BF00261500. PMid:2808898.
http://dx.doi.org/10.1007/BF00261500...

10. Gregson RK, Shannon H, Stocks J, Cole TJ, Peters MJ, Main E. The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children. Pediatr Crit Care Med. 2012;13(2):e97-102. http://dx.doi.org/10.1097/PCC.0b013e3182230f5a. PMid:21666530.
http://dx.doi.org/10.1097/PCC.0b013e3182...
-1111. Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149., as well as in patients with cystic fibrosis33. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...
, in animal models88. Martí JD, Li Bassi G, Rigol M, Saucedo L, Ranzani OT, Esperatti M, et al. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation. Crit Care Med. 2013;41(3):850-6. http://dx.doi.org/10.1097/CCM.0b013e3182711b52. PMid:23314585.
http://dx.doi.org/10.1097/CCM.0b013e3182...
,1212. Wong WP, Paratz JD, Wilson K, Burns YR. Hemodynamic and ventilatory effects of manual respiratory physiotherapy techniques of chest clapping, vibration, and shaking in an animal model. J Appl Physiol. 2003;95(3):991-8. http://dx.doi.org/10.1152/japplphysiol.00249.2003. PMid:12754172.
http://dx.doi.org/10.1152/japplphysiol.0...
. Some studies showed positive effects88. Martí JD, Li Bassi G, Rigol M, Saucedo L, Ranzani OT, Esperatti M, et al. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation. Crit Care Med. 2013;41(3):850-6. http://dx.doi.org/10.1097/CCM.0b013e3182711b52. PMid:23314585.
http://dx.doi.org/10.1097/CCM.0b013e3182...
,1313. Berti JS, Tonon E, Ronchi CF, Berti HW, Stefano LM, Gut AL, et al. Manual hyperinflation combined with expiratory rib cage compression for reduction of length of ICU stay in critically ill patients on mechanical ventilation. J Bras Pneumol. 2012;38(4):477-86. http://dx.doi.org/10.1590/S1806-37132012000400010. PMid:22964932.
http://dx.doi.org/10.1590/S1806-37132012...
, but another study showed negative effects on clinical outcomes with CWC, such as expiratory flow limitation (EFL)66. Guimarães FS, Lopes AJ, Constantino SS, Lima JC, Canuto P, Menezes SL. Expiratory rib cage compression, secretion clearance and respiratory mechanics in mechanically ventilated patients: A randomized crossover trial. Respir Care. 2014;59(5):678-85. http://dx.doi.org/10.4187/respcare.02587. PMid:24106324.
http://dx.doi.org/10.4187/respcare.02587...
.

It has also been reported that many physical therapists often use manual chest physical therapy techniques in patients with acute exacerbations of chronic obstructive pulmonary disease (COPD)1414. Osadnik CR, McDonald CF, Holland AE. Airway clearance techniques in acute exacerbations of COPD: a survey of Australian physiotherapy practice. Physiotherapy. 2013;99(2):101-6. http://dx.doi.org/10.1016/j.physio.2012.01.002. PMid:23219648.
http://dx.doi.org/10.1016/j.physio.2012....
. It is great of importance for physical therapists to know the physiological effects of CWC in patients with COPD. It may also be harder to increase expiratory flow rates with CWC in COPD patients, because many COPD patients often show difficulty increasing expiratory flow rates because of airflow limitation1515. Johnson BD, Weisman IM, Zeballos RJ, Beck KC. Emerging concepts in the evaluation of ventilatory limitation during exercise: the exercise tidal flow-volume loop. Chest. 1999;116(2):488-503. http://dx.doi.org/10.1378/chest.116.2.488. PMid:10453881.
http://dx.doi.org/10.1378/chest.116.2.48...
. However, there have been no reports of the physiological effects of CWC in patients with COPD.

The purpose of this study was to compare the effects of CWC on expiratory flow rates in patients with COPD and asymptomatic controls. We hypothesized that expiratory flow rates during CWC are harder to increase in COPD patients.

Method

Participants

This study was approved by the Hyogo College of Medicine, Nishinomiya-shi, Hyogo, Japan Ethics Committee (approval number 1189). Written, informed consent was obtained from all eligible participants. The study included fourteen clinically stable patients with stage I to IV COPD according to the Global Initiative for Chronic Obstructive Lung Disease guidelines (COPD group) who were receiving pulmonary rehabilitation at the Hyogo College of Medicine Sasayama Medical Center between October 2012 and September 2013 and who could perform spirometric testing according to the ATS/ERS Task Force Guidelines1616. Miller MR, Crapo R, Hankinson J, Brusasco V, Burgos F, Casaburi R, et al. General considerations for lung function testing. Eur Respir J. 2005;26(1):153-61. http://dx.doi.org/10.1183/09031936.05.00034505. PMid:15994402.
http://dx.doi.org/10.1183/09031936.05.00...
. Forced expiratory volume in the first second (FEV1) and forced vital capacity (FVC) were expressed as predicted percentage values for age, sex, and height, established by the Japanese Respiratory Society1717. Hanamoto S, Ohsuji T, Tsuyuguchi I, Kawabata S, Kimura K. Prediction formulas for pulmonary function tests expressed in linear and exponential form for healthy Japanese adults. Nihon Kyobu Shikkan Gakkai Zasshi. 1992;30(12):2051-60. PMid:1289624.. The patients were clinically stable for ≥4 weeks. Exclusion criteria were suspected asthma, other systemic conditions that could contribute to dyspnea or exercise limitation (e.g. heart failure or metabolic disorders), and neuromuscular comorbidity limiting all measurements or non-approval for study participation. All COPD patients continued their regular treatment (all COPD patients used inhaled long-acting beta 2-agonists or long-acting muscarinic antagonists, and one patient used an inhaled corticosteroid). No changes in the medications were made for the purpose of the study. Fourteen age-matched healthy subjects were also consecutively recruited from the local community (healthy control group).

Measurement procedures

All measurements were collected with the subjects in supine position. Airflow rates and lung volume changes during 1 minute of quiet breathing and during 1 minute of CWC were measured via a mouth filter (PIF-1A; MINATO Medical Science, Osaka, Japan) with a heated pneumotachograph (AE300-s; MINATO Medical Science). A mouth filter was used to avoid cross-infection. CWC was applied to each subject during expiration by a male physical therapist with 8 years of clinical experience in pulmonary physical therapy. The physical therapist stood on the right side of the subject and placed both hands on the subject's upper rib cage (upper part from the sixth rib). CWC was started from the beginning of expiration to the end of expiration. The highest tolerable level of force was applied to the subject's chest wall then released as soon as the subject began inspiration. The subject was asked to avoid actively expiring during the application of CWC but to inspire freely. All subjects also performed the inspiratory capacity (IC) maneuver at the start during quiet breathing (QB) and at the end during CWC to correct the volume measuring errors ("drift")1515. Johnson BD, Weisman IM, Zeballos RJ, Beck KC. Emerging concepts in the evaluation of ventilatory limitation during exercise: the exercise tidal flow-volume loop. Chest. 1999;116(2):488-503. http://dx.doi.org/10.1378/chest.116.2.488. PMid:10453881.
http://dx.doi.org/10.1378/chest.116.2.48...
.

Airflow and lung volume data were examined using an analysis system (PowerLab, ADInstruments, Castle Hill, NSW, Australia). The last five breaths during QB and CWC were analyzed, and the mean values for Ti (inspiratory time), Te (expiratory time), Ttot (total breathing cycle time), Ti/Ttot (duty cycle), Vt (tidal volume), PIFR (peak inspiratory flow rate), PEFR (peak expiratory flow rate), PEFR/PIFR, Vt/Ti (mean inspiratory flow rate), and Vt/Te (mean expiratory flow rate) were obtained for each subject.

Flow volume (FV) curve analysis was also performed by calculating the average FV curves from the last five breaths during QB and CWC1818. Nozoe M, Mase K, Murakami S, Okada M, Ogino T, Matsushita K, et al. Relationship between spontaneous expiratory flow-volume curve pattern and air-flow obstruction in elderly COPD patients. Respir Care. 2013;58(10):1643-8. http://dx.doi.org/10.4187/respcare.02296. PMid:23571516.
http://dx.doi.org/10.4187/respcare.02296...
. The same analysis system (PowerLab, ADInstruments) was also used for averaging FV curves. The expiratory flow rate changes during QB and CWC were then examined at the same lung volume (PEFR during QB and at 50% and 25% of tidal volume during QB) and any overlap in the regions of the FV curves was determined. The presence of overlap was defined as a difference in the airflow rates within 5% between the two FV curves at the same lung volume.

Sample size calculation

The effects of CWC in COPD patients have not been reported. The sample size was calculated using the differences in PEFR with the application of CWC in the first seven subjects in each group. The mean difference in the between-group comparison was 0.195 L/sec (standard deviation (SD) 0.183). A sample size of 14 subjects per group was thus required for this study to have 80% power with alpha of 0.05.

Statistical analysis

The results are shown as means±SD. Normality of the measurement data was examined using the Kolmogorov-Smirnov test. The unpaired Student's t-test or Mann-Whitney's U-test was used to compare demographic characteristics and lung function. The between-group sex distribution was compared using chi-square analysis. Within-group comparisons by CWC intervention were done using the paired Student's t-test or Wilcoxon's rank-sum test, and between-group comparisons by CWC intervention were done using the unpaired Student's t-test or Mann-Whitney's U-test. A chi-square analysis was performed to compare the ratios of subjects who showed overlapping regions between the COPD group and the healthy control group. All tests were performed at a significance level of P<0.05. Analyses were performed with statistical software (SPSS 20, SPSS, Chicago, IL, USA).

Results

Table 1 shows the baseline characteristics of the study participants. There were significant differences between the groups in pulmonary function.

Table 1.
Baseline characteristics of the study participants.

Table 2 shows the breathing pattern and lung volume changes during QB and CWC. Ti, Te, Ttot, Vt, IC, PIFR, PEFR, and Vt/Ti increased significantly, and Ti/Ttot decreased significantly more during CWC than during QB, both in the COPD group and in the healthy control group, but Vt/Te increased significantly more during CWC than during QB only in the healthy control group. As a result, PIFR/PEFR was not different during QB and CWC in both groups. In the between group comparisons, Vt, PIFR, PEFR, Vt/Ti, and Vt/Te were significantly higher in the healthy control group than in the COPD group.

Table 2.
Changes in breathing patterns and lung volumes during QB and CWC in both groups.

Table 3 shows the expiratory flow rates at the same lung volume during QB and CWC. The expiratory flow rates at the lung volume at PEFR during QB and at 50% and 25% of tidal volume during QB were higher only in the healthy control group, but not in the COPD group with CWC.

Table 3.
Changes in expiratory flow rates at the same lung volume during QB and CWC in both groups.

Figure 1 shows representative FV curves during QB and CWC in the COPD group and the healthy control group. The left FV curves in the healthy control group show increased expiratory flow rates at all lung volumes. In contrast, the right FV curves in the COPD group show increased expiratory flow rates during CWC at the beginning of expiration, but not at the end of expiration, and the FV curves had overlapping regions. Less than half of the subjects in the healthy control group (6/14 subjects; 43%) had overlapping regions in the FV curves, but almost all subjects in the COPD group had overlapping regions (13/14 subjects; 93%, P<0.05). All overlapping regions were seen at the end of expiration.

Figure 1.
Representative flow-volume curves during QB and CWC. The left side shows a healthy subject, and the right side shows a COPD patient. QB: quiet breathing; CWC: chest wall compression; COPD: chronic obstructive pulmonary disease.

Discussion

In this study, the effects of CWC were examined in COPD patients, and it was confirmed that PEFR increased during CWC in these patients. However, PEFR changes during CWC were lower in COPD patients than in healthy subjects. The reason for the difference may have been the presence of expiratory flow limitation (EFL) in the COPD patients. With EFL, the expiratory flow rates never increase with increased pleural pressure, and this is often seen in patients with severe COPD1919. Koulouris NG, Kaltsakas G, Palamidas AF, Gennimata SA. Methods for assessing expiratory flow limitation during tidal breathing in COPD patients. Pulm Med. 2012; 2012: 1-8.. Ninane et al.2020. Ninane V, Leduc D, Kafi SA, Nasser M, Houa M, Sergysels R. Detection of expiratory flow limitation by manual compression of the abdominal wall. Am J Respir Crit Care Med. 2001;163(6):1326-30. http://dx.doi.org/10.1164/ajrccm.163.6.2004150. PMid:11371396.
http://dx.doi.org/10.1164/ajrccm.163.6.2...
reported assessment of EFL by studying whether the expiratory flow rates could be increased by increased pleural and abdominal pressures with abdominal compression during expiration. In the present study, CWC also increased pleural pressure by upper rib cage compression, but the participants whose expiratory flow rates did not increase during CWC probably had EFL, though the area of compression differed from that of Ninane et al.2020. Ninane V, Leduc D, Kafi SA, Nasser M, Houa M, Sergysels R. Detection of expiratory flow limitation by manual compression of the abdominal wall. Am J Respir Crit Care Med. 2001;163(6):1326-30. http://dx.doi.org/10.1164/ajrccm.163.6.2004150. PMid:11371396.
http://dx.doi.org/10.1164/ajrccm.163.6.2...
. In fact, almost all COPD patients showed overlapping regions in the FV curves during QB and CWC, which suggests that it is difficult for COPD patients to increase expiratory flow rates during CWC. One more reason to consider for the discrepancy in PEFR changes between healthy and COPD participants is the increase in Vt with CWC. Generally, increasing Vt provides higher elastic forces at the start of exhalation, therefore healthy subjects have a tendency to increase expiratory flow rates more than COPD patients do.

In this study, expiratory flow rate changes during CWC were also examined using FV curves. PEFR and Vt have often been measured during various chest physical therapy techniques22. Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149.,44. McCarren B, Alison JA, Herbert RD. Manual vibration increases expiratory flow rate via increased intrapleural pressure in healthy adults: an experimental study. Aust J Physiother. 2006;52(4):267-71. http://dx.doi.org/10.1016/S0004-9514(06)70006-X. PMid:17132121.
http://dx.doi.org/10.1016/S0004-9514(06)...
,77. Genc A, Akan M, Gunerli A. The effects of manual hyperinflation with or without rib-cage compression in mechanically ventilated patients. Italian Journal of Physiotherapy. 2011;1(2):48-54., but FV curves during these interventions have not been previously studied, except in a recent study on patients on mechanical ventilation66. Guimarães FS, Lopes AJ, Constantino SS, Lima JC, Canuto P, Menezes SL. Expiratory rib cage compression, secretion clearance and respiratory mechanics in mechanically ventilated patients: A randomized crossover trial. Respir Care. 2014;59(5):678-85. http://dx.doi.org/10.4187/respcare.02587. PMid:24106324.
http://dx.doi.org/10.4187/respcare.02587...
. The advantage of using FV curve assessment is to examine the expiratory flow changes at absolute volume in peripheral airway regions33. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...
. The expiratory flow rates at the lung volume at PEFR during QB and at 50% and 25% of tidal volume during QB increased only in the healthy control group, but not in the COPD group. Moreover, almost all COPD patients showed overlapping regions in the FV curves. This showed that it is difficult for COPD patients to increase expiratory flow in peripheral airways with CWC.

The present results showed that PEFR/PIFR did not change with CWC in the COPD group or in the healthy control group. McCarren and Alison33. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...
reported that PEFR/PIFR increased during vibration to 1.51 in CF patients. It was concluded that vibration was useful for CF patients because the PEFR/PIFR value needs to increase to more than 1.1 to remove secretions33. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...
. However, there were some differences between their methods and the present methods. They asked their subjects to inspire to total lung capacity as slowly as possible33. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...
. On the other hand, they did not ask subjects to inspire slowly in their other study of normal healthy subjects55. McCarren B, Alison JA, Herbert RD. Vibration and its effect on the respiratory system. Aust J Physiother. 2006;52(1):39-43. http://dx.doi.org/10.1016/S0004-9514(06)70060-5. PMid:16515421.
http://dx.doi.org/10.1016/S0004-9514(06)...
. In the present study, the participants were instructed to inspire freely, therefore it was not possible to determine inspiratory lung volume and breathing speed. McCarren et al.55. McCarren B, Alison JA, Herbert RD. Vibration and its effect on the respiratory system. Aust J Physiother. 2006;52(1):39-43. http://dx.doi.org/10.1016/S0004-9514(06)70060-5. PMid:16515421.
http://dx.doi.org/10.1016/S0004-9514(06)...
reported that not only PEFR but also PIFR increased during CWC in normal subjects, so that PEFR/PIFR decreased more during CWC (to 0.64) than during QB (to 0.72). These results suggest that CWC must be combined with slow deep inspiration for effective removal of secretions. In the present results, Ti, Te, and Ttot also increased during CWC in both groups. Such changes were also seen during pursed-lips breathing (PLB) in COPD patients2121. Bianchi R, Gigliotti F, Romagnoli I, Lanini B, Castellani C, Binazzi B, et al. Patterns of chest wall kinematics during volitional pursed-lip breathing in COPD at rest. Respir Med. 2007;101(7):1412-8. http://dx.doi.org/10.1016/j.rmed.2007.01.021. PMid:17350815.
http://dx.doi.org/10.1016/j.rmed.2007.01...
,2222. Bianchi R, Gigliotti F, Romagnoli I, Lanini B, Castellani C, Grazzini M, et al. Chest wall kinematics and breathlessness during pursed-lip breathing in patients with COPD. Chest. 2004;125(2):459-65. http://dx.doi.org/10.1378/chest.125.2.459. PMid:14769725.
http://dx.doi.org/10.1378/chest.125.2.45...
because of the increased inspiratory effort during PLB. We hypothesized that increased inspiratory effort was the result of maintaining ventilation, because decreased respiratory frequency was seen not only during PLB but also CWC. Furthermore, we believe that the reason for the greater PIFR and Vt/Ti changes with CWC in the healthy control group compared to the COPD group was the presence of hyperinflation in COPD patients. It is known that lung hyperinflation leads to decreased inspiratory flow reserve by the increased elastic recoil pressure of the lung or the decreased inspiratory muscle-generated force1515. Johnson BD, Weisman IM, Zeballos RJ, Beck KC. Emerging concepts in the evaluation of ventilatory limitation during exercise: the exercise tidal flow-volume loop. Chest. 1999;116(2):488-503. http://dx.doi.org/10.1378/chest.116.2.488. PMid:10453881.
http://dx.doi.org/10.1378/chest.116.2.48...
.

In the present results, tidal volume was increased with CWC in both groups, but the increase was greater in the healthy control group than in the COPD group. We thought this difference was also explained by the differences in Vt/Ti between the groups. In contrast, IC increased with CWC in both groups. It is known that IC changes are associated with changes in end expiratory lung volume, so this technique may reduce hyperinflation, such as that shown in PLB2121. Bianchi R, Gigliotti F, Romagnoli I, Lanini B, Castellani C, Binazzi B, et al. Patterns of chest wall kinematics during volitional pursed-lip breathing in COPD at rest. Respir Med. 2007;101(7):1412-8. http://dx.doi.org/10.1016/j.rmed.2007.01.021. PMid:17350815.
http://dx.doi.org/10.1016/j.rmed.2007.01...
,2222. Bianchi R, Gigliotti F, Romagnoli I, Lanini B, Castellani C, Grazzini M, et al. Chest wall kinematics and breathlessness during pursed-lip breathing in patients with COPD. Chest. 2004;125(2):459-65. http://dx.doi.org/10.1378/chest.125.2.459. PMid:14769725.
http://dx.doi.org/10.1378/chest.125.2.45...
. In fact, CWC has been used as a technique to reduce dyspnea by reducing hyperinflation, particularly in Japanese clinical practice2323. Yoshimi K, Ueki J, Seyama K, Takizawa M, Yamaguchi S, Kitahara E, et al. Pulmonary rehabilitation program including respiratory conditioning for chronic obstructive pulmonary disease (COPD): Improved hyperinflation and expiratory flow during tidal breathing. J Thorac Dis. 2012;4(3):259-64. PMid:22754664..

Limitations of the study

CWC effects were measured in the supine position, but this position may affect the expiratory flow changes. Koulouris et al.2424. Koulouris NG, Valta P, Lavoie A, Corbeil C, Chassé M, Braidy J, et al. A simple method to detect expiratory flow limitation during spontaneous breathing. Eur Respir J. 1995;8(2):306-13. http://dx.doi.org/10.1183/09031936.95.08020306. PMid:7758567.
http://dx.doi.org/10.1183/09031936.95.08...
reported that COPD patients often have EFL, particularly in the supine position. The decreased functional residual capacity (FRC) in the supine position decreases elastic lung recoil and expiratory flow reserve. On the other hand, McCarren et al.44. McCarren B, Alison JA, Herbert RD. Manual vibration increases expiratory flow rate via increased intrapleural pressure in healthy adults: an experimental study. Aust J Physiother. 2006;52(4):267-71. http://dx.doi.org/10.1016/S0004-9514(06)70006-X. PMid:17132121.
http://dx.doi.org/10.1016/S0004-9514(06)...
applied CWC to their subjects in the lateral recumbent position. FRC values are higher in the lateral recumbent position than in the supine position2525. Lumb AB, Nunn JF. Respiratory function and ribcage contribution to ventilation in body positions commonly used during anesthesia. Anesth Analg. 1991;73(4):422-6. http://dx.doi.org/10.1213/00000539-199110000-00010. PMid:1897767.
http://dx.doi.org/10.1213/00000539-19911...
, so these differences may have affected the present results. However, the supine position was chosen because it provides more powerful chest compression, as shown by Toussaint et al.2626. Toussaint M, Boitano LJ, Gathot V, Steens M, Soudon P. Limits of effective cough-augmentation techniques in patients with neuromuscular disease. Respir Care. 2009;54(3):359-66. PMid:19245730.. Moreover, CWC was applied to the upper rib cage in the present study, even though it was applied to the lower rib cage in other studies22. Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149.

3. McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605. PMid:16455834.
http://dx.doi.org/10.1183/09031936.06.00...

4. McCarren B, Alison JA, Herbert RD. Manual vibration increases expiratory flow rate via increased intrapleural pressure in healthy adults: an experimental study. Aust J Physiother. 2006;52(4):267-71. http://dx.doi.org/10.1016/S0004-9514(06)70006-X. PMid:17132121.
http://dx.doi.org/10.1016/S0004-9514(06)...
-55. McCarren B, Alison JA, Herbert RD. Vibration and its effect on the respiratory system. Aust J Physiother. 2006;52(1):39-43. http://dx.doi.org/10.1016/S0004-9514(06)70060-5. PMid:16515421.
http://dx.doi.org/10.1016/S0004-9514(06)...
. It is more difficult to apply CWC to the lower rib cage due to the presence of breasts in women; since there were subjects of both sexes in this sample, applying CWC to the upper rib cage was an alternative to achieve better standardization. Some of the healthy subjects in the present study also had overlapping regions in their FV curves. This may be due to age-related changes. The present subjects included many elderly persons, and their mean age was also very advanced. Since it is known that elastic lung recoil pressure and FRC decrease with age2727. Janssens JP, Pache JC, Nicod LP. Physiological changes in respiratory function associated with ageing. Eur Respir J. 1999;13(1):197-205. http://dx.doi.org/10.1183/09031936.99.14614549. PMid:10836348.
http://dx.doi.org/10.1183/09031936.99.14...
, some of the present healthy subjects may have had EFL. However, expiratory flow rates and tidal volume were different between the COPD group and the healthy control group. Thus, there appears to be a difference in the effects of CWC depending on the presence of COPD, even if age-related effects are excluded.

Another possible limitation was that changes in the amounts of secretions with CWC intervention and the longitudinal effects of CWC were not measured. Since the subjects were not asked to inspire to total lung capacity, the lung volume effects could not be controlled. It has been reported that chest physical therapy technique has low reliability2828. Shannon H, Gregson R, Stocks J, Cole TJ, Main E. Repeatability of physiotherapy chest wall vibrations applied to spontaneously breathing adults. Physiotherapy. 2009;95(1):36-42. http://dx.doi.org/10.1016/j.physio.2008.08.004. PMid:19627684.
http://dx.doi.org/10.1016/j.physio.2008....
. In the present study, the effects of CWC performed by one physical therapist were examined, so that the same results may not be generalized to other physical therapists. Moreover, either the physical therapist or the assessor were not blinded. This lack of blinding may also affect the results of the study.

Clinical implications

In this study, peak expiratory flow rates, but not mean expiratory flow rates, increased in COPD patients. Volpe et al.2929. Volpe MS, Adams AB, Amato MBP, Marini JJ. Ventilation patterns influence airway secretion movement. Respir Care. 2008;53(10):1287-94. PMid:18811989. reported that peak expiratory and inspiratory flows are the key factors in secretion removal, not mean expiratory and inspiratory flows. Therefore, we believe that it would be effective to use CWC in patients with COPD to remove secretions when combined with slow inspiration, even though it would be less effective than in healthy subjects. We also showed that IC increased with CWC, so this technique may reduce hyperinflation and dyspnea.

Conclusion

The present results showed higher PEFR during CWC than during QB, both in COPD patients and in healthy subjects, but absolute expiratory flow rates during CWC increased only in healthy subjects, not in COPD patients. As a result, PEFR and Vt/Te increased with CWC more in healthy subjects than in COPD patients. Although CWC appears to be less effective in increasing absolute expiratory flow rates in COPD patients than in healthy subjects, the PEFR, which is more effective for removing secretions, did increase in the COPD group.

References

  • 1
    Branson RD. Secretion management in the mechanically ventilated patient. Respir Care. 2007;52(10):1328-42, discussion 1342-7. PMid:17894902.
  • 2
    Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149.
  • 3
    McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J. 2006;27(6):1204-9. http://dx.doi.org/10.1183/09031936.06.00083605 PMid:16455834.
    » http://dx.doi.org/10.1183/09031936.06.00083605
  • 4
    McCarren B, Alison JA, Herbert RD. Manual vibration increases expiratory flow rate via increased intrapleural pressure in healthy adults: an experimental study. Aust J Physiother. 2006;52(4):267-71. http://dx.doi.org/10.1016/S0004-9514(06)70006-X PMid:17132121.
    » http://dx.doi.org/10.1016/S0004-9514(06)70006-X
  • 5
    McCarren B, Alison JA, Herbert RD. Vibration and its effect on the respiratory system. Aust J Physiother. 2006;52(1):39-43. http://dx.doi.org/10.1016/S0004-9514(06)70060-5 PMid:16515421.
    » http://dx.doi.org/10.1016/S0004-9514(06)70060-5
  • 6
    Guimarães FS, Lopes AJ, Constantino SS, Lima JC, Canuto P, Menezes SL. Expiratory rib cage compression, secretion clearance and respiratory mechanics in mechanically ventilated patients: A randomized crossover trial. Respir Care. 2014;59(5):678-85. http://dx.doi.org/10.4187/respcare.02587 PMid:24106324.
    » http://dx.doi.org/10.4187/respcare.02587
  • 7
    Genc A, Akan M, Gunerli A. The effects of manual hyperinflation with or without rib-cage compression in mechanically ventilated patients. Italian Journal of Physiotherapy. 2011;1(2):48-54.
  • 8
    Martí JD, Li Bassi G, Rigol M, Saucedo L, Ranzani OT, Esperatti M, et al. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation. Crit Care Med. 2013;41(3):850-6. http://dx.doi.org/10.1097/CCM.0b013e3182711b52 PMid:23314585.
    » http://dx.doi.org/10.1097/CCM.0b013e3182711b52
  • 9
    MacLean D, Drummond G, Macpherson C, McLaren G, Prescott R. Maximum expiratory airflow during chest physiotherapy on ventilated patients before and after the application of an abdominal binder. Intensive Care Med. 1989;15(6):396-9. http://dx.doi.org/10.1007/BF00261500 PMid:2808898.
    » http://dx.doi.org/10.1007/BF00261500
  • 10
    Gregson RK, Shannon H, Stocks J, Cole TJ, Peters MJ, Main E. The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children. Pediatr Crit Care Med. 2012;13(2):e97-102. http://dx.doi.org/10.1097/PCC.0b013e3182230f5a PMid:21666530.
    » http://dx.doi.org/10.1097/PCC.0b013e3182230f5a
  • 11
    Unoki T, Kawasaki Y, Mizutani T, Fujino Y, Yanagisawa Y, Ishimatsu S, et al. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation. Respir Care. 2005;50(11):1430-7. PMid:16253149.
  • 12
    Wong WP, Paratz JD, Wilson K, Burns YR. Hemodynamic and ventilatory effects of manual respiratory physiotherapy techniques of chest clapping, vibration, and shaking in an animal model. J Appl Physiol. 2003;95(3):991-8. http://dx.doi.org/10.1152/japplphysiol.00249.2003 PMid:12754172.
    » http://dx.doi.org/10.1152/japplphysiol.00249.2003
  • 13
    Berti JS, Tonon E, Ronchi CF, Berti HW, Stefano LM, Gut AL, et al. Manual hyperinflation combined with expiratory rib cage compression for reduction of length of ICU stay in critically ill patients on mechanical ventilation. J Bras Pneumol. 2012;38(4):477-86. http://dx.doi.org/10.1590/S1806-37132012000400010 PMid:22964932.
    » http://dx.doi.org/10.1590/S1806-37132012000400010
  • 14
    Osadnik CR, McDonald CF, Holland AE. Airway clearance techniques in acute exacerbations of COPD: a survey of Australian physiotherapy practice. Physiotherapy. 2013;99(2):101-6. http://dx.doi.org/10.1016/j.physio.2012.01.002 PMid:23219648.
    » http://dx.doi.org/10.1016/j.physio.2012.01.002
  • 15
    Johnson BD, Weisman IM, Zeballos RJ, Beck KC. Emerging concepts in the evaluation of ventilatory limitation during exercise: the exercise tidal flow-volume loop. Chest. 1999;116(2):488-503. http://dx.doi.org/10.1378/chest.116.2.488 PMid:10453881.
    » http://dx.doi.org/10.1378/chest.116.2.488
  • 16
    Miller MR, Crapo R, Hankinson J, Brusasco V, Burgos F, Casaburi R, et al. General considerations for lung function testing. Eur Respir J. 2005;26(1):153-61. http://dx.doi.org/10.1183/09031936.05.00034505 PMid:15994402.
    » http://dx.doi.org/10.1183/09031936.05.00034505
  • 17
    Hanamoto S, Ohsuji T, Tsuyuguchi I, Kawabata S, Kimura K. Prediction formulas for pulmonary function tests expressed in linear and exponential form for healthy Japanese adults. Nihon Kyobu Shikkan Gakkai Zasshi. 1992;30(12):2051-60. PMid:1289624.
  • 18
    Nozoe M, Mase K, Murakami S, Okada M, Ogino T, Matsushita K, et al. Relationship between spontaneous expiratory flow-volume curve pattern and air-flow obstruction in elderly COPD patients. Respir Care. 2013;58(10):1643-8. http://dx.doi.org/10.4187/respcare.02296 PMid:23571516.
    » http://dx.doi.org/10.4187/respcare.02296
  • 19
    Koulouris NG, Kaltsakas G, Palamidas AF, Gennimata SA. Methods for assessing expiratory flow limitation during tidal breathing in COPD patients. Pulm Med. 2012; 2012: 1-8.
  • 20
    Ninane V, Leduc D, Kafi SA, Nasser M, Houa M, Sergysels R. Detection of expiratory flow limitation by manual compression of the abdominal wall. Am J Respir Crit Care Med. 2001;163(6):1326-30. http://dx.doi.org/10.1164/ajrccm.163.6.2004150 PMid:11371396.
    » http://dx.doi.org/10.1164/ajrccm.163.6.2004150
  • 21
    Bianchi R, Gigliotti F, Romagnoli I, Lanini B, Castellani C, Binazzi B, et al. Patterns of chest wall kinematics during volitional pursed-lip breathing in COPD at rest. Respir Med. 2007;101(7):1412-8. http://dx.doi.org/10.1016/j.rmed.2007.01.021 PMid:17350815.
    » http://dx.doi.org/10.1016/j.rmed.2007.01.021
  • 22
    Bianchi R, Gigliotti F, Romagnoli I, Lanini B, Castellani C, Grazzini M, et al. Chest wall kinematics and breathlessness during pursed-lip breathing in patients with COPD. Chest. 2004;125(2):459-65. http://dx.doi.org/10.1378/chest.125.2.459 PMid:14769725.
    » http://dx.doi.org/10.1378/chest.125.2.459
  • 23
    Yoshimi K, Ueki J, Seyama K, Takizawa M, Yamaguchi S, Kitahara E, et al. Pulmonary rehabilitation program including respiratory conditioning for chronic obstructive pulmonary disease (COPD): Improved hyperinflation and expiratory flow during tidal breathing. J Thorac Dis. 2012;4(3):259-64. PMid:22754664.
  • 24
    Koulouris NG, Valta P, Lavoie A, Corbeil C, Chassé M, Braidy J, et al. A simple method to detect expiratory flow limitation during spontaneous breathing. Eur Respir J. 1995;8(2):306-13. http://dx.doi.org/10.1183/09031936.95.08020306 PMid:7758567.
    » http://dx.doi.org/10.1183/09031936.95.08020306
  • 25
    Lumb AB, Nunn JF. Respiratory function and ribcage contribution to ventilation in body positions commonly used during anesthesia. Anesth Analg. 1991;73(4):422-6. http://dx.doi.org/10.1213/00000539-199110000-00010 PMid:1897767.
    » http://dx.doi.org/10.1213/00000539-199110000-00010
  • 26
    Toussaint M, Boitano LJ, Gathot V, Steens M, Soudon P. Limits of effective cough-augmentation techniques in patients with neuromuscular disease. Respir Care. 2009;54(3):359-66. PMid:19245730.
  • 27
    Janssens JP, Pache JC, Nicod LP. Physiological changes in respiratory function associated with ageing. Eur Respir J. 1999;13(1):197-205. http://dx.doi.org/10.1183/09031936.99.14614549 PMid:10836348.
    » http://dx.doi.org/10.1183/09031936.99.14614549
  • 28
    Shannon H, Gregson R, Stocks J, Cole TJ, Main E. Repeatability of physiotherapy chest wall vibrations applied to spontaneously breathing adults. Physiotherapy. 2009;95(1):36-42. http://dx.doi.org/10.1016/j.physio.2008.08.004 PMid:19627684.
    » http://dx.doi.org/10.1016/j.physio.2008.08.004
  • 29
    Volpe MS, Adams AB, Amato MBP, Marini JJ. Ventilation patterns influence airway secretion movement. Respir Care. 2008;53(10):1287-94. PMid:18811989.

Publication Dates

  • Publication in this collection
    15 Mar 2016
  • Date of issue
    Mar-Apr 2016

History

  • Received
    07 Mar 2015
  • Reviewed
    21 July 2015
  • Accepted
    15 Oct 2015
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia Rod. Washington Luís, Km 235, Caixa Postal 676, CEP 13565-905 - São Carlos, SP - Brasil, Tel./Fax: 55 16 3351 8755 - São Carlos - SP - Brazil