Acessibilidade / Reportar erro

Tomographic study of the atlas concerning screw fixation on lateral mass

Abstracts

INTRODUCTION: Harms's technique for atlanto-axial arthrodesis fusion makes possible the use of intraoperative reduction maneuvers of the atlanto-axial dislocation and facilitates the fixation of this joint, especially in hiperkyphotic patients and in situations where the fixation with transarticular screw on C1-C2 segment is impossible. OBJECTIVE: to describe the morphometric parameters of atlases related to the Harms's technique for atlanto-axial arthrodesis, the optimal path and the safety aisle for screw insertion into atlas' lateral mass measured with multiplanar reconstruction imaging with helical computed tomography scan at the planes. MATERIALS AND METHODS: 30 atlases of local origin have been submitted to computed tomography imaging and measured with digital cursor. RESULTS: The posteroanterior length of the implant measured 16.5 mm to the right and 16.3 mm to the left. When using it as entry point at the central portion of the lateral mass just below the posterior arc, the path must have a congruence of 15º in the coronal plan and an upper angle of 20º at the sagittal plane. CONCLUSION: The safety aisle for screw fixation into the lateral mass would have a lower bending of 22º and an upper bending of 33º at sagittal plane and 36º medially and 26° laterally, at the axial plane.

Atlanto-axial joint; Arthrodesis; Tomography


INTRODUÇÃO: A técnica de Harms para a realização da artrodese atlantoaxial possibilita o uso de manobras de redução transoperatória da subluxação atlantoaxial e facilita a fixação dessa articulação, principalmente nos pacientes hipercifóticos e nas situações em que há impossibilidade da fixação com o parafuso transarticular C1-C2. OBJETIVOS: descrever os parâmetros morfométricos do atlas relacionados à técnica de Harms para a artrodese C1-C2, o trajeto ideal e o corredor de segurança da inserção do parafuso na massa lateral do atlas mensurados através de imagens de reconstrução multiplanar com tomografia computadorizada helicoidal nos planos. MATERIAIS E MÉTODOS: trinta atlas de origem local foram submetidos a tomografia computadorizada e mensurados com cursor digital. RESULTADOS: o comprimento posteroanterior do implante mediu 16,5 mm à direita e 16,3mm à esquerda. Quando utilizando como ponto de entrada na porção central da massa lateral imediatamente inferior ao arco posterior, o trajeto deve ter uma congruência de 15º no plano coronal e uma angulação superior de 20º no plano sagital. CONCLUSÃO: O corredor de segurança para um parafuso na massa lateral teria uma inclinação inferior de 22º e superior de 33º no plano sagital e no plano axial de 36º medial e 26º lateral.

Articulação atlanto-axial; Artrodese; Tomografia


ORIGINAL ARTICLE

Tomographic study of the atlas concerning screw fixation on lateral mass

Max Franco de CarvalhoI, II; Roberta Teixeira RochaI; João Tiago Silva MonteiroI; Carlos Umberto PereiraI; Ricardo Ferreira LeiteI; Helton Luiz Aparecido DefinoII

IDepartment of Medicine, Federal University of Sergipe, Brazil

IIDepartment of Biomechanics, Medicine, and Locomotive Apparatus Rehabilitation, Medical School of Ribeirão Preto -USP, SP, Brazil

Correspondences to Correspondences to: Rua José Seabra Batista, 255; Condomínio: Tyrol; Edifício Innsbruck; Apto:1204, Jardins Aracaju-Sergipe- Brasil. CEP:49025-750 Email: carvalhomax@hotmail.com

ABSTRACT

INTRODUCTION: Harms's technique for atlanto-axial arthrodesis fusion makes possible the use of intraoperative reduction maneuvers of the atlanto-axial dislocation and facilitates the fixation of this joint, especially in hiperkyphotic patients and in situations where the fixation with transarticular screw on C1-C2 segment is impossible.

OBJECTIVE: to describe the morphometric parameters of atlases related to the Harms's technique for atlanto-axial arthrodesis, the optimal path and the safety aisle for screw insertion into atlas' lateral mass measured with multiplanar reconstruction imaging with helical computed tomography scan at the planes.

MATERIALS AND METHODS: 30 atlases of local origin have been submitted to computed tomography imaging and measured with digital cursor.

RESULTS: The posteroanterior length of the implant measured 16.5 mm to the right and 16.3 mm to the left. When using it as entry point at the central portion of the lateral mass just below the posterior arc, the path must have a congruence of 15º in the coronal plan and an upper angle of 20º at the sagittal plane.

CONCLUSION: The safety aisle for screw fixation into the lateral mass would have a lower bending of 22º and an upper bending of 33º at sagittal plane and 36º medially and 26° laterally, at the axial plane.

Keywords: Atlanto-axial joint. Arthrodesis. Tomography.

INTRODUCTION

High cervical spine anatomy is responsible for the segment with the highest degree of mobility in the whole vertebral spine. Due to these unique characteristics, both the first and the second cervical vertebrae present different morphological characteristics from the other cervical vertebrae.1-4

Pathologies of the craniocervical joint may be caused by trauma, tumors, congenital malformations or rheumatic pathologies. With the development of imaging diagnostic methods and surgical techniques, a significant increase of the number of surgical procedures was seen on this region.5,6

The key objective of most surgical procedures on atlanto-axial joint is to achieve intervertebral union. The most employed arthrodesis techniques are: Brooks- or Gallie-type ligation, interlaminar clamp, Magerl's transarticular technique, translaminar screw on atlas, and screw on lateral mass.5-16 Atlas fixation with screws on the lateral mass was introduced by Goel and Laheri14, but the technique was disseminated by Harms and Mecher15 with the development of a system composed by a polyaxial screw and nail.

Biomechanical studies proved that Magerl's transarticular technique and the screw on C1 lateral mass technique associated to screw at the C2 pedicle provide the same stability level as in laboratory studies.17 However, these systems are more stable than the different ligation techniques. The size of C2 isthmus can prevent transarticular screw fixation in approximately 20% of the patients.6 The possibility of using atlanto-axial dislocation reduction maneuvers after the insertion of screws on C1 and C2 of the lateral mass, has enabled an advancement on reducing and fixating atlanto-axial instability.15

In recent years, the safety of Harms' technique has been described in several studies.12,14,15,17-19 Lateral mass provides a structure that is large enough to accommodate a 3.5-mm screw. However, the near distance from vertebral artery, from the second cervical nerve's ganglion, and from the spinal cord can cause serious iatrogenic injuries should the screw is inserted out of the lateral mass. The objective of this study is to describe the safety zone for fixating screws on the lateral mass of dried vertebrae using a multiplanar reconstruction assay with multiplanar helical computed tomography machine.

MATERIALS AND METHODS

Thirty cervical vertebrae (C1 or Atlas) removed from human unidentified cadavers were obtained by donation of the Urban Services Company (EMURB) of the city of Aracaju – Sergipe – Brazil, according to report nr. 047/2005. The vertebrae were removed from local individuals buried as indigents, and no distinction was made concerning gender, age or ethnicity. After dissection, cleaning and fixation, the vertebrae were numbered for subsequent classification and X-ray analysis by means of helical computed tomography (Toshiba Asteion TSX – 021A/1A, 1-mm thick sections). After measurements were performed, 5 vertebrae were randomly selected and tomographically re-scanning and re-measuring these for studying the error.

The screw insertion point was determined by following the Harms' technique (15) at the central portion of the lateral mass just below the posterior arch, as seen on 3-dimensional images. Then, through multiplanar studies, safety zones were found for inserting screw on the lateral mass, following the parameters: anterior height (distance between upper and lower surfaces of the most anterior portion of atlas' lateral mass); lateral height (distance between the insertion point and the lower posterior end of the atlas' lateral mass); posterior height (distance between the upper and lower surfaces of the most posterior portion of atlas' lateral mass); cross-sectional diameter (largest distance from medial surface to the lateral portion of atlas' lateral mass at a cross-sectional foramen level); anteroposterior length (distance between the anterior cortical of atlas' lateral mass at sagittal plane and the insertion point); upper angle (angle between one line of the insertion point up to anterior cortical and atlas' anteroinferior cortical at sagittal plane); lower angle (angle between one line of the insertion point up to anterior cortical and atlas' anteroinferior cortical at sagittal plane); medial angle (angle between one line of the insertion point up to anterior cortical and atlas' medial cortical at coronal plane), and lateral angle (angle between one line of the insertion point up to anterior cortical and atlas' lateral cortical at coronal plane). (Figures 1 and 2).



In order to assess the reproducibility of measurements, a subgroup of five vertebrae was randomly selected, which were submitted to a new tomographic test where measurements were made again by the same investigator, blinded to the results of the first measurement. For assessing intra-investigator variation, the intraclass correlation coefficient (ICC) was calculated.20,21

The consistency between both measurements was assessed by means of the ICC and of the corresponding confidence interval (95% confidence).20,21 For comparing the variables assessed for right and left sides, the linear regression model was adopted. Similarity of sides was assessed by the hypothesis test that the straight line intercept was equal to zero, and that the angle coefficient was equal to one.

RESULTS

Based on the findings of the measurements on the thirty atlas, the median, the mean, maximum, minimum and standard deviation values were calculated. Both linear and angular measurements did not show statistical difference between the values achieved and those seen at error evaluation. The reliability of these measurements is significantly higher than zero. All intraclass correlation coefficient values were close to 1, evidencing its reliability.

On the measurements of anterior height of the lateral mass, a mean value of 17.42 + 2.04 mm was found to the right and, to the left, the mean value was 17.61 + 1.88 mm. For lateral heights of the lateral mass, the mean value seen to the right was 3.83 + 0.63 mm and 3.67 + 0.61 mm to the left. In both cases, no significant differences were found between right and left sides (p > 0.05). Nevertheless, in the measurements for posterior height of the lateral mass, a significant difference was found between right and left sides (p < 0.05). The mean value seen for the right was 12.09 + 2.03 mm and for the left, 12.41 + 1.99 mm.

For cross-sectional diameter measurements, the mean value found to the right was 18.03 + 2.58 mm and to the left, 18.42 + 2.41 mm. For anteroposterior diameter, the mean value found to the right was 16.47 + 1.85 mm and 16.27 + 1.74 mm to the left. In both cases, no significant differences were found between right and left sides (p > 0.05). (Table 1)

The measurements for lower angle showed a mean value of 23.63 + 5.25 to the right, and 22.99º + 5.62º to the left. The measurements for upper angle showed a mean value of 33.73º + 6.30º to the right, and 34.44º + 5.80º to the left. The measurements for medial angle showed a mean value of 36.99º + 5.25º to the right and 36.20º + 5.07º to the left. The measurements for lateral angle showed a mean value of 26.61º + 5.21º to the right, and 26.17º + 4.98º to the left. In all angle measurements, no significant differences were found between right and left sides (p > 0.05). (Table 2)

DISCUSSION

Since Magerl and Seemann16 first described the transarticular arthrodesis technique, biomechanical studies have evidenced the biomechanical superiority of this fixation method in all motion planes of the atlanto-axial joint, including the rotation, when compared to the other ligation techniques.12,14,15,17-19

Atlas fixation achieved a great advancement, after the dissemination of a system using polyaxial screws on the lateral mass of C1 and on the pedicle of C2 by Harms and Melcher15, which enabled the use of peroperative reduction maneuvers of the atlanto-axial dislocation and made the fixation of this joint easier, especially on hyperkyphotic patients. The biomechanical study by Melcher et al.17 did not show significant difference between this new method and the transarticular fixation.

According to Harms and Melcher15 and Melcher et al.17 the screw insertion point on the lateral mass must be located at the middle of the posterior C1 arch joint and the middle of the lower portion and posterior surface of the lateral mass. The screw path should be straight or a little medially convergent towards the posteroanterior plane, parallel to C1 posterior arch at sagittal plane towards the anterior arch. On the description of the technique, the need to palpate lateral masses with a Penfield-like retractor protecting the vertebral artery, the vertebral canal, and the second cervical nerve has always been emphasized.

Tan et al.19 reported atlas fixation through posterior arch. The insertion point would be at 19.01 mm laterally to the mean line of the posterior arch, and at 2.03 mm superiorly to the lower edge of the posterior arch. The thickness of the vertebral groove would be 9.51 + 2.09 mm to the right, and 9.68 + 2.40 mm to the left. Of the 50 studied vertebrae, only 4 (8%), the thickness of the posterior arch has shown to be thinner than 4 mm. In these cases, the fixation must be made through lateral or transarticular mass. Ebraheimet al.22 measured the dimensions of the vertebral artery groove and found that the thickness of the vertebral groove was 4.1+ 1.2 mm. After an anatomical and X-ray study of dried atlas removed from Brazilian cadavers, Carvalho et al.23 found a mean inter-investigator thickness of 3.87 + 0.83 mm to the right and 3.92 + 1.10 mm to the left. These findings precluded fixation through the posterior arch as suggested by Tan et al.19

Honget al.24 conducted an anatomical study of the lateral mass of 30 atlas and found that the screw insertion point would be an intersection point between the lower edge of the posterior arch and the center of the lateral mass. The optimal end point for the screw would be situated at 3-4 mm from the lower joint facet. The screw should be preferably inserted with a convergence of 15º and with a cephalic bend of 23º at sagittal plane.

At the insertion place recommended in our study, the lateral mass showed a mean width of 18.03 mm on the right and 18.42 mm on the left, posterior height of the lateral mass of 12.09 mm on the right and 12.41 mm on the left. All studied vertebrae showed enough space for a safe fixation of a 3.5 mm-thick screw on the lateral mass. However, a height comprehended between the insertion point and the lower edge of the lateral mass was 3.83 mm on the right and 3.67 mm on the left. In these cases, the surgeon must resect 10 mm of the atlas' posterior arch to enable an easy screw insertion.

In an anatomical study, Wang and Samudrala25 described how to position a screw on the lateral mass, which should have a straight direction. However, a maximum medial and lateral angulation of 33° and 13°, respectively, would be allowed at the coronal plane, and a maximum upper and lower angulation of 19º and 0º, respectively, at sagittal plane.

According to our findings, the screw on lateral mass should be approximately 16 mm long. When using an insertion point at the central portion of the lateral mass just beneath the posterior arch, the path should have a congruence of 15º at coronal plane, and an upper angle of 20º at sagittal plane. The safety zone for a screw on lateral mass would be a lower and upper bending of 22º and 33º respectively at the sagittal plane, and a medial and lateral bending of approximately 36° and 26°, respectively, at the axial plane.

CONCLUSION

The fixation with screw on atlas' lateral mass is certainly a surgical technique that enabled spine surgeons to achieve better outcomes in cases of atlanto-axial joint dislocation. Our study has shown that, in all atlas studied here, this technique is a safe procedure. However, the preparation of the insertion point and the awareness of the safety zone for inserting the screw are critical factors for avoiding an iatrogenic injury.

REFERENCES

1. Breathnach AS. Frazer's anatomy of the human skeleton. 6th. ed. London: J. Churchill Livingstone; 1965.

2. Agur AMR, Ming J, Grant JCB. Grant's atlas of anatomy. Baltimore: Willians & Wilkins; 1962.

3. Gray H. Anatomy, descriptive and surgical. New York: Bounty Books, 1901.

4. Francis C. Dimensions of the cervical vertebrae. Anat Rec. 1955;122:603-9.

5. Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86:961-8.

6. Nogueira-Barbosa M. Reconstruções multiplanares da tomografia computadorizada no estudo da artrodese atlanto-axial transarticular [dissertação]. Ribeirão Preto: Universidade de São Paulo; 2004. 86p.

7. Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am. 1978;60:279-84.

8. Davey JR, Rorabech CH, Bailey SI. A technique of posterior cervical fusion for instability of the cervical spine. Spine. 1985;10:722-8.

9. Foustas KN, Smisson HF 3rd, Robinson JS Jr. C1–C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience. Neurosurgery. 2002;50:672-3.

10. Mihara H, Cheng BC, David SM, Ohnari K, Zdeblick TA. Biomechanical comparison of posterior cervical fixation. Spine. 2001 26:1662-7.

11. Kanat A, Aydin Y. Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery. 1999;44:687-9.

12. Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine. 2002;16:1724-32.

13. Tokuhashi Y, Matsuzaki H, Shirasaki Y, Tateishi T. C1-C2 intra articular screw fixation for atlantoaxial posterior stabilization. Spine- 2000;25:337-41.

14. Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994;129:47-53.

15. Harms J, Melcher RP. Posterior C1-C2 fusion with poliaxial screw and rod fixation. Spine. 2001;26:2467-71.

16. Magerl F, Seemann PS. Stable posterior fusion of the atlas and axis by trans-articular screw fixation. In: Weidner A, Kehr P editors. Cervical spine J. New York: Springer Verlag; 1987.

17. Melcher RP, Puttlitz CM, Kleinstueck SF, Lotz JC, Harms J, Bradford DS. Biomechanical testing of posterior atlantoaxial posterior fixation: techniques. Spine. 2002;22:2435-40.

18. Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T. Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine. 2003;28:666-70.

19. Tan M, Wang H, Wang Y, Zhang G, Yi P, Li Z. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine. 2003;28:888-95.

20. Prieto L, Lamarca R, Casado A. Assessment ot the reliability of clinical findings: the intraclass correlation coefficient. Med Clin (Barc). 1998;110:142-5.

21. Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420-8.

22. Ebraheim NA, Xu R, Ahmad M, Heck B. The quantitative anatomy of the vertebral artery groove of the atlas and its relation to the posterior atlantoaxial approach. Spine.1998;23:320-3.

23. Carvalho MF, Monteiro JT, Pereira CU. Morfometria do atlas.. In: XI Encontro de Iniciação Científica da Universidade Federal de Sergipe. Anais do Congresso. Aracaju- Sergipe-Brasil; 2006; p. 58.

24. Hong X, Dong Y, Chang Y, Yin Q, Zong S, Liu J. Posterior screw placement on the lateral mass of lateral mass of atlas: an anatomic study. Spine. 2004;29:500-3.

25. Wang MY, Samudrala S. Cadaveric morphometric analysis for atlantal lateral mass screw placement. Neurosurgery. 2004;54:1436-9.

Received in: 09/10/07

approved in: 01/06/08

All the authors state no potential conflict of interest concerning this article.

  • 1. Breathnach AS. Frazer's anatomy of the human skeleton. 6th. ed. London: J. Churchill Livingstone; 1965.
  • 2. Agur AMR, Ming J, Grant JCB. Grant's atlas of anatomy. Baltimore: Willians & Wilkins; 1962.
  • 3. Gray H. Anatomy, descriptive and surgical. New York: Bounty Books, 1901.
  • 4. Francis C. Dimensions of the cervical vertebrae. Anat Rec. 1955;122:603-9.
  • 5. Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86:961-8.
  • 6. Nogueira-Barbosa M. Reconstruções multiplanares da tomografia computadorizada no estudo da artrodese atlanto-axial transarticular [dissertação]. Ribeirão Preto: Universidade de São Paulo; 2004. 86p.
  • 7. Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am. 1978;60:279-84.
  • 8. Davey JR, Rorabech CH, Bailey SI. A technique of posterior cervical fusion for instability of the cervical spine. Spine. 1985;10:722-8.
  • 9. Foustas KN, Smisson HF 3rd, Robinson JS Jr. C1C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience. Neurosurgery. 2002;50:672-3.
  • 10. Mihara H, Cheng BC, David SM, Ohnari K, Zdeblick TA. Biomechanical comparison of posterior cervical fixation. Spine. 2001 26:1662-7.
  • 11. Kanat A, Aydin Y. Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery. 1999;44:687-9.
  • 12. Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine. 2002;16:1724-32.
  • 13. Tokuhashi Y, Matsuzaki H, Shirasaki Y, Tateishi T. C1-C2 intra articular screw fixation for atlantoaxial posterior stabilization. Spine- 2000;25:337-41.
  • 14. Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994;129:47-53.
  • 15. Harms J, Melcher RP. Posterior C1-C2 fusion with poliaxial screw and rod fixation. Spine. 2001;26:2467-71.
  • 16. Magerl F, Seemann PS. Stable posterior fusion of the atlas and axis by trans-articular screw fixation. In: Weidner A, Kehr P editors. Cervical spine J. New York: Springer Verlag; 1987.
  • 17. Melcher RP, Puttlitz CM, Kleinstueck SF, Lotz JC, Harms J, Bradford DS. Biomechanical testing of posterior atlantoaxial posterior fixation: techniques. Spine. 2002;22:2435-40.
  • 18. Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T. Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine. 2003;28:666-70.
  • 19. Tan M, Wang H, Wang Y, Zhang G, Yi P, Li Z. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine. 2003;28:888-95.
  • 20. Prieto L, Lamarca R, Casado A. Assessment ot the reliability of clinical findings: the intraclass correlation coefficient. Med Clin (Barc). 1998;110:142-5.
  • 21. Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420-8.
  • 22. Ebraheim NA, Xu R, Ahmad M, Heck B. The quantitative anatomy of the vertebral artery groove of the atlas and its relation to the posterior atlantoaxial approach. Spine.1998;23:320-3.
  • 23. Carvalho MF, Monteiro JT, Pereira CU. Morfometria do atlas.. In: XI Encontro de Iniciação Científica da Universidade Federal de Sergipe. Anais do Congresso. Aracaju- Sergipe-Brasil; 2006; p. 58.
  • 24. Hong X, Dong Y, Chang Y, Yin Q, Zong S, Liu J. Posterior screw placement on the lateral mass of lateral mass of atlas: an anatomic study. Spine. 2004;29:500-3.
  • 25. Wang MY, Samudrala S. Cadaveric morphometric analysis for atlantal lateral mass screw placement. Neurosurgery. 2004;54:1436-9.
  • Correspondences to:

    Rua José Seabra Batista, 255; Condomínio: Tyrol; Edifício Innsbruck; Apto:1204, Jardins
    Aracaju-Sergipe- Brasil. CEP:49025-750
    Email:
  • Publication Dates

    • Publication in this collection
      17 July 2009
    • Date of issue
      2009

    History

    • Accepted
      06 Jan 2009
    • Received
      10 Sept 2007
    ATHA EDITORA Rua: Machado Bittencourt, 190, 4º andar - Vila Mariana - São Paulo Capital - CEP 04044-000, Telefone: 55-11-5087-9502 - São Paulo - SP - Brazil
    E-mail: actaortopedicabrasileira@uol.com.br