Acessibilidade / Reportar erro

Development of a filtration system with high-frequency flow reversal

Desenvolvimento de um sistema de filtragem com reversão de fluxo de alta frequência

ABSTRACT

The aim of this study was to develop a filtration system with high-frequency flow reversal and minimum requirement of water for cleaning routines. The system was developed in the period from 2011 to 2013 and consists of three screen filters and eleven solenoid valves electronically controlled by a controller that operates based on head loss measurements. The following evaluations were carried out: head loss curve as a function of flow rate; filtrating efficiency as a function of solids concentration, frequency of flow reversal and increment in head loss. The experimental design was completely randomized in a factorial scheme with three replicates and two treatment levels for each factor. The filtration efficiency was equal to 98.6% for particles larger than 50 µm. The minimum volume of water for each cleaning of the filters was 5.39 L. The head loss increment in the filtration system with flow reversal at frequencies of 11.11 and 22.22 mHz was smaller compared with the filtration system without flow reversal. The developed filtration system has potential for filtering low-quality irrigation water, but requires periodic maintenance to clean the filter element.

Key words:
water quality; emitter clogging; screen filter

RESUMO

Este trabalho objetivou desenvolver um sistema de filtragem com inversão automática de fluxo de alta frequência e consumo mínimo de água de limpeza. O sistema foi desenvolvido no período de 2011 a 2013 e é composto de três filtros de tela e onze válvulas solenoides, acionadas eletronicamente por controlador baseado na perda de carga. Avaliou-se a curva de perda de carga em função da vazão e a eficiência de filtragem em função da concentração de sólidos, frequência de inversão de fluxo e incremento da perda de carga. O delineamento experimental foi inteiramente aleatorizado em esquema fatorial com três repetições e dois níveis de tratamento para cada fator. A eficiência de filtragem para sólidos maiores que 50 µm foi de 98,6%. O volume mínimo de água para cada limpeza dos filtros foi de 5,39 L. A inversão de fluxo com frequências de 11,11 e 22,22 mHz reduziu a taxa de crescimento da perda de carga comparado ao sistema funcionando sem inversão de fluxo. O sistema de filtragem apresentou potencial para filtragem da água de baixa qualidade para irrigação porém necessita de manutenções periódicas para limpeza do elemento filtrante.

Palavras-chave:
qualidade da água; obstrução de emissores; filtro de tela

Introduction

Emitter clogging may compromise the application uniformity of micro-irrigation systems due to the uneven reduction in the flow rate of the emitters; in addition, a reduction in the applied water depth may occur (Batista et al., 2010Batista, R. O.; Souza, J. A. R.; Ferreira, D. C. Influência da aplicação de esgoto doméstico tratado no desempenho de um sistema de irrigação. Revista Ceres, v.57, p.18-22, 2010. http://dx.doi.org/10.1590/S0034-737X2010000100004
http://dx.doi.org/10.1590/S0034-737X2010...
; Ribeiro et al., 2008Ribeiro, T. A. P.; Paterniani, J. E. S.; Colleti, C. Chemical treatment to unclogg dripper irrigation systems due to biological problems. Scientia Agricola, v.65, p.1-9, 2008. http://dx.doi.org/10.1590/S0103-90162008000100001
http://dx.doi.org/10.1590/S0103-90162008...
). Increase in emitter clogging of approximately 1 to 5% may result in great loss of application uniformity (Nakayama & Books, 1981Nakayama, F. S.; Bucks, D. A. Emitter clogging effects on trickle irrigation uniformity. Transactions of the ASAE, v.24, p.77-80, 1981. http://dx.doi.org/10.13031/2013.34203
http://dx.doi.org/10.13031/2013.34203...
). According to Frizzone et al. (2012)Frizzone, J. A.; Freitas, P. S. L.; Rezende, R.; Faria, M. A. Microirrigação: Gotejamento e microaspersão. 1.ed. Maringá: Eduem, 2012. 356p., the total clogging of 5 to 10% of the emitters promotes coefficients of variation in the flow rate from 23 to 33%. Additionally, according to Camargo et al. (2013)Camargo, A. P.; Molle, B.; Tomas, S.; Frizzone, J. A. An assessment of clogging effects on lateral hydraulics: proposing a monitoring and detection protocol. Irrigation Science, v.33, p.181-191, 2013. , the effect of emitter clogging on the hydraulic variables of the lateral line depends on the location of the clogged emitters.

Although the causing agents of emitter clogging have different natures, i.e., physical, chemical or biological, Adin & Alon (1986)Adin, A.; Alon, G. Mechanisms and process parameters of filter screens. Journal of Irrigation and Drainage Engineering, v.112, p.293-304, 1986.http://dx.doi.org/10.1061/(ASCE)0733-9437(1989)115:3(474)
http://dx.doi.org/10.1061/(ASCE)0733-943...
observed that most of the causes of clogging are due to the presence of materials in suspension, showing the importance of a filtration system for micro-irrigation. It should be pointed out that the prevention of emitter clogging should not be based only on agents of physical nature, but also on the other agents, in combination, because in many cases they occur simultaneously (Lemos Filho et al., 2011Lemos Filho, A. F.; Zanini, J. R.; Silva, E. R. S.; Cazetta, J. O.; Ferraudo, A. S. Sistema com aeração, decantação e filtragem para a melhoria da qualidade de água em irrigação localizada. Engenharia Agrícola, v.31, p.506-519, 2011. http://dx.doi.org/10.1590/S0100-69162011000300011
http://dx.doi.org/10.1590/S0100-69162011...
; Pinto et al., 2011Pinto, M. F.; Camargo, A. P.; Almeida, Alves, D. G.; Botrel, T. A. Desenvolvimento de um sistema para controle do pH da água para microirrigação. Revista Brasileira de Engenharia Agrícola e Ambiental, v.15, p.211-217, 2011.http://dx.doi.org/10.1590/S1415-43662011000200015
http://dx.doi.org/10.1590/S1415-43662011...
).

Thus, various studies have shown that filtration systems can be more or less efficient due to the different natures of the causing agents of clogging. According to Testezlaf (2008)Testezlaf, R. Filtros de areia aplicados à irrigação localizada: teoria e prática. Engenharia Agrícola, v.28, p.604-613, 2008. http://dx.doi.org/10.1590/S0100-69162008000300020
http://dx.doi.org/10.1590/S0100-69162008...
, sand filters are recommended for the removal of organic contaminants and algae, while screen or disc filters should be used to retain solid particles of physical nature, which is the reason why they are commonly used after the sand filter, in order to retain particles from fertilizer injection systems (Frizzone et al., 2012Frizzone, J. A.; Freitas, P. S. L.; Rezende, R.; Faria, M. A. Microirrigação: Gotejamento e microaspersão. 1.ed. Maringá: Eduem, 2012. 356p.).

Many studies have confirmed that screen or disc filters are efficient at retaining small-diameter solid particles; however, when subjected to water of low quality, with large amount of impurities, such as algae and organic matter, they are very susceptible to clogging and require frequent cleanings (Adin & Elimelech, 1989Adin, A.; Elimelech, M. Particle filtration for wastewater irrigation. Journal of Irrigation and Drainage Engineering, v.115, p.474-487, 1989.; Tajrishy et al., 1994Tajrishy, M. A.; Hills D. J.; Tchobanoglous, G. Pretreatment of secondary effluent for drip irrigation. Journal of Irrigation and Drainage, v.120, p.716-731, 1994.; Puig-Bargués et al., 2005Puig-Bargués, J.; Arbat, G.; Barragán, J.; Cartagena, F. R. Effluent particle removal by microirrigation system filters. Spanish Journal of Agricultural Research, v.3, p.182-191, 2005. http://dx.doi.org/10.5424/sjar/2005032-139
http://dx.doi.org/10.5424/sjar/2005032-1...
; Duran-Ros et al. 2009aDuran-Ros, M.; Puig-Bargués, M. J.; Arbat, G. Effect of filter, emitter and location on clogging when using effluents. Agricultural Water Management, v.96, p.67-79, 2009a. http://dx.doi.org/10.1016/j.agwat.2008.06.005
http://dx.doi.org/10.1016/j.agwat.2008.0...
). All of these authors evaluated the screen filter subjected to wastewater and observed that its clogging occurred rapidly, and Tajrishy et al. (1994)Tajrishy, M. A.; Hills D. J.; Tchobanoglous, G. Pretreatment of secondary effluent for drip irrigation. Journal of Irrigation and Drainage, v.120, p.716-731, 1994. reported the necessity of daily cleanings considering a head loss limit of 55 kPa. Puig-Bargués et al. (2005)Puig-Bargués, J.; Arbat, G.; Barragán, J.; Cartagena, F. R. Effluent particle removal by microirrigation system filters. Spanish Journal of Agricultural Research, v.3, p.182-191, 2005. http://dx.doi.org/10.5424/sjar/2005032-139
http://dx.doi.org/10.5424/sjar/2005032-1...
and Duran-Ros et al. (2009a)Duran-Ros, M.; Puig-Bargués, M. J.; Arbat, G. Effect of filter, emitter and location on clogging when using effluents. Agricultural Water Management, v.96, p.67-79, 2009a. http://dx.doi.org/10.1016/j.agwat.2008.06.005
http://dx.doi.org/10.1016/j.agwat.2008.0...
observed that, when screen or disc filters are clogged, particles may detach due to the increase in pressure, reducing the efficiency or even increasing the concentration of solids in suspension. However, the results found by these authors were obtained with filters working in the traditional way, i.e., without flow reversal. According to Testezlaf & Ramos (1995)Testezlaf, R.; Ramos, J. P. S. Sistema automatizado para determinação de perda de carga em filtros de tela e disco usados na irrigação localizada. Pesquisa Agropecuária Brasileira, v.30, p.1079-1088, 1995., screen filters must be cleaned immediately after use, in order to prevent particles from becoming strongly aggregated, which makes their removal difficult. High-frequency flow reversal may promote the removal of these particles.

Given the above, this study aimed to develop an automatic filtration system with high-frequency flow reversal, high efficiency and low water requirement for cleaning.

Material and Methods

Description and characterization of the filtration system

The filtration system was developed from 2011 to 2013 and consists of three filters (model: Amiad 1" Super with filter element of 130-µm screen and nominal flow rate of 7 m3 h-1) and eleven electronically controlled solenoid valves (model: Bermad 220-M DN-25, with flow rate of 5.5 m3 h-1 for a head loss of 30 kPa).

The prototype assembly scheme is shown in Figure 1A, where the components F1, F2 and F3 represent filters, V1 to V8 the flow-direction control valves and VL1, VL2 and VL3 represent valves for the cleaning of the filters.

Figure 1
Assembly scheme of the filtration system (A) and the prototype (B)

The components were interconnected using fittings and pipes. The configuration, composed of three filters, aimed to condition the flow reversal in the filters with the system in operation, by activating the sequence of valves as shown inTable 1. Each sequence of opening of the valves promotes a pathway for the water in the filtration system, as described by Pinto (2013)Pinto, M. F. Desenvolvimento e avaliação de um sistema de filtragem com reversão de fluxo de alta frequência. Piracicaba: ESALQ/USP, 2013. 99p. Tese Doutorado. http://dx.doi.org/10.11606/t.11.2013.tde-12072013-082758
http://dx.doi.org/10.11606/t.11.2013.tde...
.

Table 1
Sequence of opening of the valves as a function of the filter in reversal and/or under cleaning

The head loss curve as a function of flow rate was determined and the tests were performed using clean water for the three operation conditions of the system (F1, F2 and F3 in reversal, individually). Eleven flow rate points were tested, varying from 0.5 to 5.5 m3 h-1 with increments of 0.5 m3 h-1. This number of points is higher than the seven points recommended by the norm ASAE S 539 (ASABE, 2008ASABE - American Society of Agricultural and Biological Engineers. ASAE S 539. Media filters for irrigation - Testing and performance. St. Joseph: ASABE, 2008. 7p.). Head loss was determined using a differential mercury manometer installed between the inlet and the outlet of the filtration system. Flow rate was determined using an electromagnetic meter installed before the filtration system and controlled using a valve installed after the meter. The pressure in the inlet of the system was maintained at 196.2 kPa and the head loss curve as a function of the flow rate was adjusted to a potential model.

Minimization of cleaning water volume

The water volume required for the cleaning of each filter depends on the water pressure inside the filter and on the time of opening of its cleaning valve. In order to minimize this water volume, different combinations of opening times of cleaning valves were analysed, according to Table 2. The opening time of each valve ranged from 0.25 to 2.0 s and the opening was performed using electrical pulses. Three consecutive electrical pulses, spaced by 1 s, were adopted; therefore, the total opening time of the valve in each filter cleaning ranged from 1 to 3 s.

Table 2
Combinations of pulse times to open the cleaning valves of the filters F1, F2 and F3, used in the tests of the system

Cleanings were performed when the head loss increment reached 50%. For each combination of time, the cleaning water was collected for volume determination. Time combinations that were not tested were due to ineffective cleaning.

Evaluation of the filtration system's retention efficiency

Filtration efficiency was measured in tests performed in completely randomized design, in 2 x 2 x 2 factorial scheme, with three replicates. The following factors were considered: concentration of solids larger than 50 µm (500 and 1000 mg L-1); flow reversal frequency (11.11 and 22.22 mHz) and head loss increment for filter cleaning (25 and 50%).

The composition of the concentration of solids was obtained through the injection of solids directly into the inlet pipe of the filtration system, using the arrangement of valves installed in the piping, as shown in Figure 2. Particle injection rates were 33.3 and 16.7 g min-1 for the concentrations of 1000 and 500 mg L-1, respectively, since the flow rate of the filtration system was 2 m3h-1.

Figure 2
Scheme of the solids injection system

Retention efficiency was obtained based on the total mass of solids in the inlet and the total mass of solids retained by the filters (Eq. 1). In addition, the efficiency of retention of solids larger than 50 µm was determined, i.e., referring to particles injected into the pipes (Eq. 2). For each treatment level, samples of the water used in the tests and cleaning water were collected and the total mass of solids used in the tests was obtained by drying the samples in an oven.

The filtered volume was measured using a water meter with flow rate range from 0 to 2.5 m3 h-1 and the volume of cleaning water was determined through weighing, as in the tests of minimum volume.

where:

Er - filtration efficiency, %;

Ed>50 - filtration efficiency for solids with diameter larger than 50 µm, %;

mr - mass of solids with diameter larger than 50 µm, retained by the filters, g;

mt - mass of solids injected into the filters, g;

Cl - concentration of solids with diameter smaller than 50 µm, present in the cleaning water, g L-1;

Ce - concentration of solids with diameter larger than 50 µm injected in the inlet of the system, g L-1;

V - filtered volume, L; and,

Vl - volume of cleaning water, L.

For the separation of particles with diameters larger and smaller than 50 µm, a sieve (ABNT n° 270, 53 µm) was connected to the inlet of the container for the collection of cleaning water, where the solids of the sand fraction were retained.

Results and Discussion

Curve of flow rate x head loss in clean water

The characteristic head loss curve as a function of the inlet flow rate of the filtration system, with screen filter, for the three operating conditions, i.e., with one of the filters in reversal, is shown in Figure 3. The curve showed a potential behavior, as suggested byTestezlaf & Ramos (1995)Testezlaf, R.; Ramos, J. P. S. Sistema automatizado para determinação de perda de carga em filtros de tela e disco usados na irrigação localizada. Pesquisa Agropecuária Brasileira, v.30, p.1079-1088, 1995. andOliveira et al. (2007)Oliveira, C. F.; Frizzone, J. A.; Rettore Neto, O. Recomendação de equações para determinação da perda de carga em filtros de tela. Revista Brasileira de Agricultura Irrigada, v.1, p.3-8, 2007. http://dx.doi.org/10.7127/rbai.v1n100005
http://dx.doi.org/10.7127/rbai.v1n100005...
. Even considering the three flow directions, the potential model adjusted well to the data and showed a coefficient of determination of 0.9986.

Figure 3
Characteristic curve of head loss as a function of the inlet flow rate of the filtration system

For the flow rate of 5 m3 h-1, the head loss in the filtration system was approximately 196.2 kPa and, for the three filters in series, it would be approximately 60 kPa, because the value for each filter was 20 kPa, evidencing that other components of the system contributed to the head loss, especially the control valves. Each valve showed head loss of 24 kPa, in a total of 96 kPa for the four valves, which represents 48.9% of the total head loss.

In order to decrease the head loss in the system, it would be interesting to reduce the number of fittings that cause abrupt changes in water flow, especially by using direct-acting valves, but they have a relatively high cost compared with indirectacting hydraulic valves. In addition, the electrical power required for activation would be much higher.

Minimization of cleaning water volume

The results of cleaning water volume as a function of valve opening time are shown in Table 3. The lowest water volume for filter cleaning was 5.35 L (5.34 = 2.2(F1) + 1.69(F2) + 1.46(F3)) resulting from the following combination: pulse1 = 250 ms, pulse2 = 1500 ms and pulse3 = 250 ms, for F1; pulse1 = 250 ms, pulse2 = 1000 ms and pulse3 = 250 ms, for F2; and pulse1 = 500 ms, pulse2 = 1000 ms and pulse3 = 500 ms, for F3. The other combinations of number of pulses and valve opening time showed higher water volumes and caused problems in the closure of cleaning valves, due to the presence of solid particles. The particles retained in the cleaning valve were probably eliminated in the last pulse. Therefore, cleaning the filters with three valve opening pulses was the most viable alternative.

Table 3
Volume of cleaning water for different combinations of valve opening time for the filters F1, F2 and F3

When cleaning was performed using two pulses, only the filters F1 and F2 did not have leakage in the cleaning valves. However, the water volume was higher compared with the use of three pulses, even for the situation in which the total valve opening time was the same. This occurs because the times of pulses 1 and 3 are lower than the total time of opening of the valve (0.75 s), i.e., the valve is partially open, making the flow rate lower than the maximum flow rate of the valve, which occurs after complete opening. Thus, opening times longer than that for complete opening result in maximum flow rate of the valve and, consequently, in higher volume of cleaning water.

Retention efficiency and volume of cleaning water per volume of filtered water

Considering the efficiency of retention of total solids, only the factor concentration showed significant difference at 0.01 and 0.05 probability levels, and no interaction between the factors was significant (Table 4). Thus, the effect of the concentration of solids can be analysed collectively, with Er values of 71.7 and 78.3% for the concentrations of 500 and 1000 mg L-1, respectively (Table 5).

Table 4
Result of the analysis of variance for the efficiency o f retention of solids by the system
Table 5
Filtration efficiency considering total solids and solids with diameter larger than 50 μm

The treatment with highest concentration showed the highest efficiency of retention of solids, which can be related to the particle-size distribution, i.e., the frequency with which certain particle size is associated. The frequencies associated with the diameter of 50 µm were 55.6 and 77.8%, for the treatments with 500 and 1000 mg L-1, respectively, and these results corroborate those reported by Hatukai et al. (1997)Hatukai, S.; Ben-Tzur, Y.; Rebhun, M. Particle counts and size distribution in system design for removal of turbidity by granular deep bed filtration. Water Science Technology, v.36, p.225-230, 1997. http://dx.doi.org/10.1016/S0273-1223(97)00453-8
http://dx.doi.org/10.1016/S0273-1223(97)...
and Puig-Bargués et al. (2005)Puig-Bargués, J.; Arbat, G.; Barragán, J.; Cartagena, F. R. Effluent particle removal by microirrigation system filters. Spanish Journal of Agricultural Research, v.3, p.182-191, 2005. http://dx.doi.org/10.5424/sjar/2005032-139
http://dx.doi.org/10.5424/sjar/2005032-1...
, who claimed that the determination of particle-size distribution helps in the understanding of particle retention efficiency and can detect problems that would not be evidenced by other means. In the study developed by Puig-Bargués et al. (2005)Puig-Bargués, J.; Arbat, G.; Barragán, J.; Cartagena, F. R. Effluent particle removal by microirrigation system filters. Spanish Journal of Agricultural Research, v.3, p.182-191, 2005. http://dx.doi.org/10.5424/sjar/2005032-139
http://dx.doi.org/10.5424/sjar/2005032-1...
, the analysis of particle distribution before and after the filtration identified the occurrence of aggregation of solid particles after the filter. These authors expressed the retention efficiency as a function of filter diameter and observed efficiency values ranging from 30 to 100%, which were dependent on the distribution of particles and the origin of the water.

In the present study, however, considering the retention efficiency for solids with diameter larger than 50 µm, no interaction with significant difference at 0.01 and 0.05 probability levels was observed (Table 4), with Ed > 50 of 98.6 ± 0.3%. The significance level of the factor concentration was 94.39% for total solids, while for the filtration efficiency (Er) using solids with diameter larger than 50 µm, the factor concentration was equal to 0.146%, proving that the increase in Er with the concentration of solids was influenced by the concentration of solids with diameter smaller than 50 µm.

The mean volume of water used for the cleanings in each performance test was 5.39 L per cleaning, which represented a cleaning water volume per filtered water volume of 8.0 and 12.6 L m-3, for the concentrations of 500 and 1000 mg L-1, respectively. This occurred because, for the water with lower concentration of solids (500 mg L-1), the evolution of head loss is slower and, in contrast, the number of backwashes per volume of filtered water is lower. According to Ribeiro et al. (2005)Ribeiro, T. A. P.; Paterniani, J. E. S.; Silva, M. J. M.; Airoldi, R. P. S. Efeito da qualidade da água na perda de carga em filtros utilizados na irrigação localizada. Revista Brasileira de Engenharia Agrícola e Ambiental, v.9, p.1-6, 2005. http://dx.doi.org/10.1590/S1415-43662005000100001
http://dx.doi.org/10.1590/S1415-43662005...
, the variations in the quality of irrigation water influence the evolution of head loss in filtration systems, thus interfering with the intervals of backwashes, depending on the type of filter element. However, although the lowest concentration of solids in suspension (500 mg L-1) is half of the highest concentration (1000 mg L-1), the mean water volume per cleaning did not follow the same proportion and represented 63.5% of the water volume for the highest concentration. According to Zeier & Hills (1987)Zeier, K. R.; Hills, D. J. Trickle irrigation screen filter performance as affected by sand size and concentration. Transaction of the ASAE, v.30, p.735-739, 1987. http://dx.doi.org/10.13031/2013.30468
http://dx.doi.org/10.13031/2013.30468...
, for lower concentrations, the amount of sand necessary to cause an increase in head loss is lower than that of the filtered volume and does not follow a linear relationship with the concentration. However, these authors emphasize that the volume of water per cleaning is, on average, the same.

Even for the use of water with high concentration of solids in suspension, the volumes of water required for filter cleaning can be considered as low, based on the limit of 10% of the filtered volume recommended by Tajrishy et al. (1994)Tajrishy, M. A.; Hills D. J.; Tchobanoglous, G. Pretreatment of secondary effluent for drip irrigation. Journal of Irrigation and Drainage, v.120, p.716-731, 1994.. These authors found backwash volume of 3% for sand filters with wastewater at concentration of 25 mg L-1, i.e., a concentration of solids 20 to 40 times less than that of the water used in the present study. Duran et al. (2009a,b)Duran-Ros, M.; Puig-Bargués, M. J.; Arbat, G.; Barragán, J. Cartagena, F. R. Performance and backwashing efficiency of disc and screen filters in microirrigation systems. Biosystems Engineering, v.103, p.35-42, 2009b. http://dx.doi.org/10.1016/j.biosystemseng.2009.01.017
http://dx.doi.org/10.1016/j.biosystemsen...
reported cleaning volumes of 27.7 and 3 L m-3, respectively, but for the concentration of solids in suspension of 10 mg L-1 from wastewater, i.e., a concentration of solids 100 times lower than that tested in the present study.

According to Qingsong et al. (2008)Qingsong, W.; Gang, L.; Jie, L.; Yusheng, S.; Wenchu, D.; Shuhuai, H. Evaluations of emitter clogging in drip irrigation by two-phase flow simulations and laboratory experiments. Computers and Electronics in Agriculture, v.63, p.294-303, 2008. http://dx.doi.org/10.1016/j.compag.2008.03.008
http://dx.doi.org/10.1016/j.compag.2008....
, the amount of solids suspended in the irrigation water may reach concentrations higher than 1000 mg L-1, a value adopted as one of the treatment levels of the factor concentration in the evaluation of performance of the proposed system.

Efficiency of backwash and flow reversal in filter cleaning (recovery of initial head loss)

The profile of head loss as a function of filtration time, with the system operating in flow reversal (reversal time of 15 s) for the critical head loss variation of 35% and water with concentration of solids of 1000 mg L-1, is shown in Figure 4A.

Figure 4
Profile of head loss increment as a function of the number of backwashes of the filtration system: (A) with flow reversal; (B) without flow reversal

According to Frizzone et al. (2012)Frizzone, J. A.; Freitas, P. S. L.; Rezende, R.; Faria, M. A. Microirrigação: Gotejamento e microaspersão. 1.ed. Maringá: Eduem, 2012. 356p., an ideal filter is that in which the initial head loss is recovered after one backwash; in addition, it can be classified as effective or ineffective, based on the recovery of head loss (Duran-Ros et al., 2009bDuran-Ros, M.; Puig-Bargués, M. J.; Arbat, G.; Barragán, J. Cartagena, F. R. Performance and backwashing efficiency of disc and screen filters in microirrigation systems. Biosystems Engineering, v.103, p.35-42, 2009b. http://dx.doi.org/10.1016/j.biosystemseng.2009.01.017
http://dx.doi.org/10.1016/j.biosystemsen...
), which can be noticed in Figure 4A, through both the time between backwashes and the head loss after one backwash.

It is evident that time between backwashes decreases along the test, which indicates that the cleanings were not totally effective. Additionally, for the system operating with flow reversal (Figure 4A), immediately after the first backwash, the head loss did not return to its initial value and tended to increase for the subsequent backwashes, as can be seen through the dashed line.

If this tendency continued, in 2.6 h the increment in head loss right after one cleaning would be equal to 35%, i.e., cleanings had no effect on the head loss of the filters (saturation of the control).

Although the head loss returned to its initial value until the fourth cleaning, for the system operating without flow reversal, the head loss increment rate was superior (Figure 4B) and, if this rate continued, the saturation of the system would occur in 1.4 h, a time shorter than that of the system with flow reversal. Furthermore, the numbers of backwashes per time of test were 9 and 17 h-1, for the filtration system with and without flow reversal, respectively. Therefore, it is supposed that flow reversal contributed to the removal of part of the particles retained on the screen, because the number of backwashes decreased.

The ineffectiveness of the cleanings in the recovery of the initial head loss is possibly associated with the solid particles retained on the filter screen, and its magnitude depends on particle diameter; smaller particles clog screen pores more easily in comparison to larger particles (Zeier & Hills, 1987Zeier, K. R.; Hills, D. J. Trickle irrigation screen filter performance as affected by sand size and concentration. Transaction of the ASAE, v.30, p.735-739, 1987. http://dx.doi.org/10.13031/2013.30468
http://dx.doi.org/10.13031/2013.30468...
). Testezlaf & Ramos (1995)Testezlaf, R.; Ramos, J. P. S. Sistema automatizado para determinação de perda de carga em filtros de tela e disco usados na irrigação localizada. Pesquisa Agropecuária Brasileira, v.30, p.1079-1088, 1995. comment that screen filters must be cleaned immediately after use, in order to prevent particles from becoming strongly aggregated, which compromises their removal.

When the screens were mechanically cleaned using a brush, the head loss returned to its initial value, indicating that the automatic cleanings were not effective at removing the particles retained on the screen. Thus, the proposed system will work with restrictions, requiring maintenance when the control system saturates. It should be pointed out that, when the concentration of total solids in the water is high, as in the analysed case, maintenance must be more frequent, which can make its use unviable.

Conclusions

  1. The filtration system showed good efficiency at the retention of particles.

  2. High-frequency flow reversal reduced the head loss evolution rate of the filtration system.

  3. The logic of cleaning the filters using pulses promoted minimum volume of cleaning water.

  4. The developed filtration system has potential for filtering low-quality irrigation water, but requires periodic maintenance, with manual cleaning of the filter element.

Acknowledgments

To the São Paulo Research Foundation (FAPESP), for the financial support through the research project 2010/52457-6 and to the National Institute of Science and Technology in Irrigation Engineering (INCTEI), along with the Ministry of Science and Technology (MCT), the National Council for Scientific and Technological Development (CNPq) and the Coordination for the Improvement of Higher Education Personnel (Capes).

Literature Cited

  • Adin, A.; Alon, G. Mechanisms and process parameters of filter screens. Journal of Irrigation and Drainage Engineering, v.112, p.293-304, 1986.http://dx.doi.org/10.1061/(ASCE)0733-9437(1989)115:3(474)
    » http://dx.doi.org/10.1061/(ASCE)0733-9437(1989)115:3(474)
  • Adin, A.; Elimelech, M. Particle filtration for wastewater irrigation. Journal of Irrigation and Drainage Engineering, v.115, p.474-487, 1989.
  • ASABE - American Society of Agricultural and Biological Engineers. ASAE S 539. Media filters for irrigation - Testing and performance. St. Joseph: ASABE, 2008. 7p.
  • Batista, R. O.; Souza, J. A. R.; Ferreira, D. C. Influência da aplicação de esgoto doméstico tratado no desempenho de um sistema de irrigação. Revista Ceres, v.57, p.18-22, 2010. http://dx.doi.org/10.1590/S0034-737X2010000100004
    » http://dx.doi.org/10.1590/S0034-737X2010000100004
  • Camargo, A. P.; Molle, B.; Tomas, S.; Frizzone, J. A. An assessment of clogging effects on lateral hydraulics: proposing a monitoring and detection protocol. Irrigation Science, v.33, p.181-191, 2013.
  • Duran-Ros, M.; Puig-Bargués, M. J.; Arbat, G. Effect of filter, emitter and location on clogging when using effluents. Agricultural Water Management, v.96, p.67-79, 2009a. http://dx.doi.org/10.1016/j.agwat.2008.06.005
    » http://dx.doi.org/10.1016/j.agwat.2008.06.005
  • Duran-Ros, M.; Puig-Bargués, M. J.; Arbat, G.; Barragán, J. Cartagena, F. R. Performance and backwashing efficiency of disc and screen filters in microirrigation systems. Biosystems Engineering, v.103, p.35-42, 2009b. http://dx.doi.org/10.1016/j.biosystemseng.2009.01.017
    » http://dx.doi.org/10.1016/j.biosystemseng.2009.01.017
  • Frizzone, J. A.; Freitas, P. S. L.; Rezende, R.; Faria, M. A. Microirrigação: Gotejamento e microaspersão. 1.ed. Maringá: Eduem, 2012. 356p.
  • Hatukai, S.; Ben-Tzur, Y.; Rebhun, M. Particle counts and size distribution in system design for removal of turbidity by granular deep bed filtration. Water Science Technology, v.36, p.225-230, 1997. http://dx.doi.org/10.1016/S0273-1223(97)00453-8
    » http://dx.doi.org/10.1016/S0273-1223(97)00453-8
  • Lemos Filho, A. F.; Zanini, J. R.; Silva, E. R. S.; Cazetta, J. O.; Ferraudo, A. S. Sistema com aeração, decantação e filtragem para a melhoria da qualidade de água em irrigação localizada. Engenharia Agrícola, v.31, p.506-519, 2011. http://dx.doi.org/10.1590/S0100-69162011000300011
    » http://dx.doi.org/10.1590/S0100-69162011000300011
  • Nakayama, F. S.; Bucks, D. A. Emitter clogging effects on trickle irrigation uniformity. Transactions of the ASAE, v.24, p.77-80, 1981. http://dx.doi.org/10.13031/2013.34203
    » http://dx.doi.org/10.13031/2013.34203
  • Oliveira, C. F.; Frizzone, J. A.; Rettore Neto, O. Recomendação de equações para determinação da perda de carga em filtros de tela. Revista Brasileira de Agricultura Irrigada, v.1, p.3-8, 2007. http://dx.doi.org/10.7127/rbai.v1n100005
    » http://dx.doi.org/10.7127/rbai.v1n100005
  • Pinto, M. F. Desenvolvimento e avaliação de um sistema de filtragem com reversão de fluxo de alta frequência. Piracicaba: ESALQ/USP, 2013. 99p. Tese Doutorado. http://dx.doi.org/10.11606/t.11.2013.tde-12072013-082758
    » http://dx.doi.org/10.11606/t.11.2013.tde-12072013-082758
  • Pinto, M. F.; Camargo, A. P.; Almeida, Alves, D. G.; Botrel, T. A. Desenvolvimento de um sistema para controle do pH da água para microirrigação. Revista Brasileira de Engenharia Agrícola e Ambiental, v.15, p.211-217, 2011.http://dx.doi.org/10.1590/S1415-43662011000200015
    » http://dx.doi.org/10.1590/S1415-43662011000200015
  • Puig-Bargués, J.; Arbat, G.; Barragán, J.; Cartagena, F. R. Effluent particle removal by microirrigation system filters. Spanish Journal of Agricultural Research, v.3, p.182-191, 2005. http://dx.doi.org/10.5424/sjar/2005032-139
    » http://dx.doi.org/10.5424/sjar/2005032-139
  • Qingsong, W.; Gang, L.; Jie, L.; Yusheng, S.; Wenchu, D.; Shuhuai, H. Evaluations of emitter clogging in drip irrigation by two-phase flow simulations and laboratory experiments. Computers and Electronics in Agriculture, v.63, p.294-303, 2008. http://dx.doi.org/10.1016/j.compag.2008.03.008
    » http://dx.doi.org/10.1016/j.compag.2008.03.008
  • Ribeiro, T. A. P.; Paterniani, J. E. S.; Colleti, C. Chemical treatment to unclogg dripper irrigation systems due to biological problems. Scientia Agricola, v.65, p.1-9, 2008. http://dx.doi.org/10.1590/S0103-90162008000100001
    » http://dx.doi.org/10.1590/S0103-90162008000100001
  • Ribeiro, T. A. P.; Paterniani, J. E. S.; Silva, M. J. M.; Airoldi, R. P. S. Efeito da qualidade da água na perda de carga em filtros utilizados na irrigação localizada. Revista Brasileira de Engenharia Agrícola e Ambiental, v.9, p.1-6, 2005. http://dx.doi.org/10.1590/S1415-43662005000100001
    » http://dx.doi.org/10.1590/S1415-43662005000100001
  • Tajrishy, M. A.; Hills D. J.; Tchobanoglous, G. Pretreatment of secondary effluent for drip irrigation. Journal of Irrigation and Drainage, v.120, p.716-731, 1994.
  • Testezlaf, R. Filtros de areia aplicados à irrigação localizada: teoria e prática. Engenharia Agrícola, v.28, p.604-613, 2008. http://dx.doi.org/10.1590/S0100-69162008000300020
    » http://dx.doi.org/10.1590/S0100-69162008000300020
  • Testezlaf, R.; Ramos, J. P. S. Sistema automatizado para determinação de perda de carga em filtros de tela e disco usados na irrigação localizada. Pesquisa Agropecuária Brasileira, v.30, p.1079-1088, 1995.
  • Zeier, K. R.; Hills, D. J. Trickle irrigation screen filter performance as affected by sand size and concentration. Transaction of the ASAE, v.30, p.735-739, 1987. http://dx.doi.org/10.13031/2013.30468
    » http://dx.doi.org/10.13031/2013.30468

Publication Dates

  • Publication in this collection
    Apr 2016

History

  • Received
    09 Apr 2015
  • Accepted
    04 Feb 2016
Unidade Acadêmica de Engenharia Agrícola Unidade Acadêmica de Engenharia Agrícola, UFCG, Av. Aprígio Veloso 882, Bodocongó, Bloco CM, 1º andar, CEP 58429-140, Campina Grande, PB, Brasil, Tel. +55 83 2101 1056 - Campina Grande - PB - Brazil
E-mail: revistagriambi@gmail.com