Surface modification of titanium by plasma nitriding

Abstract

A systematic investigation was undertaken on commercially pure titanium submitted to plasma nitriding. Thirteen different sets of operational parameters (nitriding time, sample temperature and plasma atmosphere) were used. Surface analyses were performed using X-ray diffraction, nuclear reaction and scanning electron microscopy. Wear tests were done with stainless steel Gracey scaler, sonic apparatus and pin-on-disc machine. The obtained results indicate that the tribological performance can be improved for samples treated with the following conditions: nitriding time of 3 h; plasma atmosphere consisting of 80%N2+20%H2 or 20%N2+80%H2; sample temperature during nitriding of 600 or 800 °C.

plasma nitriding; tribology; titanium; dental implants


Surface modification of titanium by plasma nitriding

Myriam Pereira KapczinskiI; Carlos GilII; Eder Julio KinastIII; Carlos Alberto dos SantosIII, * * e-mail: cas@if.ufrgs.br

IFaculdade de Odontologia - ULBRA Rua Miguel Tostes, 101, 92420-280 Canoas - RS, Brazil

IIFaculdade de Odontologia - USP Av. Prof. Lineu Prestes 2227, 05508-900 São Paulo - SP, Brazil

IIIInstituto de Física - UFRGS C.P. 15051, Campus do Vale, 91501-970 Porto Alegre - RS, Brazil

ABSTRACT

A systematic investigation was undertaken on commercially pure titanium submitted to plasma nitriding. Thirteen different sets of operational parameters (nitriding time, sample temperature and plasma atmosphere) were used. Surface analyses were performed using X-ray diffraction, nuclear reaction and scanning electron microscopy. Wear tests were done with stainless steel Gracey scaler, sonic apparatus and pin-on-disc machine. The obtained results indicate that the tribological performance can be improved for samples treated with the following conditions: nitriding time of 3 h; plasma atmosphere consisting of 80%N2+20%H2 or 20%N2+80%H2; sample temperature during nitriding of 600 or 800 °C.

Keywords: plasma nitriding, tribology, titanium, dental implants

1. Introduction

The biocompatibility and good corrosion resistance of commercially pure titanium (c.p. Ti) has motivated its use in medical procedures. The osseointegrated titanium implants are reliable alternatives for safety and long time treatment, representing advancement in the clinical practice mostly in dental prosthetic1-4. However, occasionally the use of c.p. Ti as implant is problematic as long as it presents low wear resistance5,6.

A crucial issue concerning the removal of the bacterial plaque from the transmucous dental implant cylinders is the possibility of damage by the routine instruments, such as stainless steel Gracey scaler, sonic and ultrasonic apparatus7-10. Such an obstacle has been bypassed using mild instrumental, but the results are not satisfactory. An obvious alternative would be the surface modification of the transmucous cylinders to provide better wear resistance. In fact, this has been the subject of several investigations in clinical dentistry4. Among the surface treatment techniques, the most reported are: plasma assisted chemical vapor deposition5, conventional ion implantation15-19, plasma source nitrogen ion implantation20, conventional nitriding21, conventional plasma nitriding22,23, intensified plasma ion nitriding24, physical and chemical vapor deposition TiN films25-28, powder immersion reaction assisted coating method29, laser heating30,31 as well as combined techniques32,33. Improvement on the mechanical and tribological properties of c.p. Ti and its alloys have been reported11-14.

Aiming the use in clinical procedures, we have started a systematic study on surface treatment of c.p. Ti. Thin film deposition, ion implantation and plasma nitriding are available at our laboratories. We intend to investigate all these processes, but due to recent technological interest we firstly decided to approach the plasma nitriding technique, whose results will be discussed in this paper.

2. Experimental

2.1 Sample preparation

Samples from the same ingot of commercially pure Ti (Atomergic Chemetals) were ground flat and mechanically polished to a 0.5 mm diamond finish and nitrided in conventional d.c. plasma-nitriding equipment similar to those previously described34,35. Preceding nitriding the specimens were ultrasonically cleaned in acetone and dried in air. Nitriding processing followed the same procedures: (i) cleaning of the treatment chamber through a four-step filling-evacuation process with nitrogen; (ii) voltage in the range from 370 to 700 V and current density from 2.5 to 5.0 mA/cm2 were adjusted to maintain the cathode temperature between 400 and 800 °C; (iii) after treatment the samples were cooled in the treatment chamber with a nitrogen atmosphere.

As previously reported for Ti-6Al-4V alloy, the total pressure has a quite little effect on the surface composition of the nitrided samples36. Therefore, this parameter was allowed to vary between 0.5 and 7.5 × 10-2 Pa. Three different plasma compositions (nitriding atmosphere) were used (80%N2-20%H2, 60%N2-40%H2, 20%N2-80%H2). The time treatment varied between 3 and 9 h. For each operational condition, two samples were prepared in the same batch.

2.2 Sample characterization

X-ray diffraction (XRD) measurements, in q-2q geometry (Bragg-Brentano goniometer) were carried out in a Siemens diffractometer with monochromated Co Ka radiation (l1 = 1.78896 Å and l2 = 1.79285 Å). All the patterns were obtained in the 2q range between 20° and 110°, with scan step of 0.05° 2q with a counting time of 2 s. The profile parameters were obtained using Rietveld refinement with the program FullProf37,38. Starting lattice parameters were taken from JCPDS39 files 44-1294 (for a-Ti), 41-1352 (for TiNx) and 38-1420 (for TiN).

Scanning electron microscopy (SEM) micrographs were obtained using Phillips XL 20 microscope equipped with energy-dispersive X-ray spectrometer (EDX). Nitrogen depth profiles were obtained from 14N(p,g)15O nuclear reaction (RNA) using the 400 kV ion implanter at the Institute of Physics - UFRGS, with protons accelerated to 278 keV. The N concentration (in at.%) is given by

where, Ccal and Scal are the count and the stopping power for the calibration (Si3N4), while Csam and Ssam stand for the same parameters for the sample40. Surface roughness measurements were made using a Talysurf 5M (Ranck Taylor Hobson) profilometer on all the samples, except for those submitted to pin-on-disc tests. Typical errors are ±10%.

2.3 Tribological experiments

To simulate clinical procedures, wear tests were performed with stainless steel Gracey scaler (SS White Duflex G11-G12) and sonic apparatus (Sonicborden 2000 N, Kavo) with universal tip #5. Both are commercial equipments used in the clinical routine. Each sample (20 × 10 × 1 mm) was demarcated in three regions. The central one was kept intact for control while the others were submitted to the tests. Two hundred unidirectional strokes were done with the Gracey scaler. The tests with the sonic apparatus were performed with bidirectional motion during 60 s, under uninterrupted water and air sprays. All the tests were performed manually by a single person, which was well trained to be reproductive.

The generic denomination "pin-on-disc" (POD) test is used for tests where a disc rotate under a pin that can have various formats (ASTM standard41). Although the use of ball instead of pin is increasing, the POD denomination continue to be used. The POD tests were performed in a tribometer (TE79 Plint &Partners) using AISI 52100 balls of 6 mm in diameter. The experiments were done during 600 s in air without lubrication, at @ 27 °C and relative humidity between 50% and 60%. A normal load of 4 N was applied on a rotating disk with 120 RPM and 3 mm of radius.

3. Results

Firstly, all the samples were submitted to tests with the sonic apparatus. Excepting for samples treated with 600 °C, 80%N2-20%H2, 3 h, 2 × 10-2 Pa and 800 °C, 20%N2-80%H2, 3 h, 2 × 10-2 Pa, all the others, including the c.p. Ti one, have shown severe damages after the test. Besides good wear performance, the sample treated at 600 °C shows coloration similar to that of the as-received one. Therefore, concerning clinical application this is the best condition. Several samples were prepared with the same operational parameters, but in different batches to evaluate the process reproducibility. The obtained result is quite favorable. In the following, the treated sample means that one nitrided at 600 °C.

SEM photomicrographs for c.p. Ti and nitrided sample are shown in Figs. 1a and 1b respectively. Surface roughness measurements indicated that the treatment increases the roughness parameter Ra (mean arithmetic deviation from the median line of the surface profile) from 0.076 mm (as-polished surface) to about 0.134 mm. Similar increasing on Ra has been early reported for c.p. Ti submitted to intensified plasma ion nitriding42. Figures 2a and 2b show SEM photomicrographs, respectively for c.p. Ti and nitrided sample submitted to test with the sonic apparatus. The areas in both figures are within the scratch of the tool. As can be seen the test with the sonic apparatus produced roughening of the surface and material loss on c.p. Ti (Ra 0.122 mm). Contrary, no macroscopic signal of damage was observed on the nitrided sample, only a subtle increasing of the brightness, which can be due to surface depressions observed under 450× SEM magnification (Fig. 2b).The Ra parameter was 0.141 mm in this surface. Patches and abrasions on the photomicrography shown in Fig. 3a indicate that c.p. Ti sample was strongly damaged after test with the Gracey scaler (Ra @ 0.143 mm), while the nitrided sample (Fig. 3b) appeared smoother after this test (0.098 mm). That is to say, while the as-nitrided sample exhibited Ra @ 0.134 mm, the nitrided sample submitted to Gracey scaler test exhibited Ra @ 0.098.




Figure 4a shows the photomicrography of c.p. Ti submitted to POD test. The wear track (@ 0.7 mm) exhibits many grooves typical of abrasive wear. For the nitrided sample, the ball track exhibited a brightness which can be attributed to surface dent. No signal of scratch was observed on this sample (see Fig. 4b). Nevertheless, as illustrated in Fig. 5, a 250× magnification photomicrography exhibited adhered material (see the inset in Fig. 5). Energy-dispersive X-ray spectrometry (EDS) performed on these wear particles showed the presence of iron and oxygen, suggesting they are from the steel ball.



The coefficient of friction (m) as a function of the sliding time for the control and nitrided samples are shown in Fig. 6. The features are typical. After an initial period of about 200 s (400 revolutions) for the control sample and about 300 s for the nitrided sample (batch #1), the coefficient of friction increases from @ 0.35 to @ 0.50 and from @ 0.10 to @ 0.50, respectively. Such a behavior can be attributed to two effects, which play in a synergetic way. From one side, the consummation of the protective layer leaves the surface more weak against wear. On the other hand, the debris so produced increase the coefficient of friction. Thus, for c.p. Ti, the native oxide layer is supposedly protective against mild wear test, while for the nitrided sample the surface layer can tolerate more severe tests. In this sense, it is interesting to point out other differences among the results obtained for these samples. Firstly, the initial value of m for the nitrided sample is about 3 times smaller than for c.p. Ti. Second, the features exhibited by the nitrided sample suggest that the wear is of the abrasive type, as this pattern is typical of wear particles at the sliding interface42,43. To properly discuss such a process it is interesting to have some insight on the physicochemical state of the sliding surfaces. As discussed below, we approached this point performing XRD and NRA measurements.


Figure 7 displays significant parts of the XRD patterns for the control and nitrided sample batch #1 (all batches gave quite similar patterns). The patterns were fitted by means of a Rietveld procedure, whose results are summarized in Table 1. The main contribution in each one of the spectra is due to a-Ti, whereas the minor ones are due to different titanium nitrides and Ti(N) solid solutions. The nitrided sample exhibited cubic phase TiN in addition to hexagonal phases a-Ti and a-TiNx44. The a-Ti phase is present with three different cell-parameter values, which we named a-Ti(1), a-Ti(2) and a-Ti(3). These phases can be attributed to different N-saturated á-phases or to sub-stoichiometric phases similar to a-TiN0.2518, a-TiN0.26 (JCPDS file 44-1095) or a-TiN0.30 (JCPDS file 41-1352).


To better understand such a result we have performed NRA to access the near-surface nitrogen concentration. As shown in Fig. 8, between 50 nm and 250 nm the N concentration is higher than 25 at.%. Between 250 nm and 400 nm the concentration is between 25 at.% and 15 at.%. The near-surface layer could provides precipitation of d-TiN, while the deeper one would be consistent with e-Ti2N precipitation19,42,45. The lack of reflections attributed to e-Ti2N in Fig. 7 is probably because its layer thickness is below the detection limit for Co Ka radiation.


4. Discussion

The test with the sonic apparatus produced on c.p. Ti an effect similar to those observed after tests with Implacare scaler and Cavitron7,10. As shown in Fig. 2a, roughening of the surface and material loss are evident. In this sense, a meaningful difference is observed when compared to the results obtained for the nitrided sample, which does not show any apparent surface damage, even at microscopic level (Fig. 2b). Taking into account data from Brookshire et al.46, the present tests are comparable to several years of implant maintenance. The different a-Ti phases detected with XRD analysis can be attributed to nitrogen, as well as to oxygen present in interstitial sites. In fact, the presence of oxide in this material is well known and has been reported by Brånemark et al.2.

Now, let us discuss the correlation between near-surface composition and tribological behavior. During the first step of the sliding experiment (up to @ 300 s for the nitrided sample), surface oxidation is promoted by the increasing of the temperature in the contact zone. As a-TiNd reacts strongly with oxygen19, a oxynitride layer quickly growth with the sliding time, resulting in a low friction coefficient. When this layer reaches a critical thickness it will peel off, producing debris and increasing the friction coefficient.

5. Summary and Conclusion

Near-surface composition and tribological behavior of plasma nitrided c.p. Ti have been investigated using X-ray diffraction, nuclear reaction analysis, scanning electron microscopy, profilometry, wear tests with stainless steel Gracey scaler and sonic apparatus, as well as friction coefficient measurements. More than 40 samples have been prepared with different nitriding conditions. Based on the tribo-oxidative wear process, the whole behavior can be divided in two steps. The first one is the growth of an oxinitride layer a-Ti(N,O)d. During the second step delamination of the oxinitride layer produces debris and increases the friction coefficient.

In conclusion, it is demonstrated that plasma nitriding is useful to improve dental implant tribological behavior.

Acknowledgments

This work was supported in part by the Brazilian agencies CAPES, CNPq(PRONEX) and FAPERGS.

7. Matarasso, S.; Quaremba, G.; Coraggio, F.; Vaia, E.; Cafiero, C.; Lang, N.P. Clin Oral Impl Res, v. 7, n. 1, p. 64-72, 1996.

8. McCollum, J.; O'Neal, R.B.; Brennan, W.A; Van Dyke, T.E.; Horner, J. Periodontol 2000, v. 63, n. 10, p. 802-805, 1992.

9. Orton, G.; Steele, D.; Wolinsky, L. Int J Oral Maxillofac Implants, v. 4, p. 305-310, 1989.

10. Rapley, J.W; Swan R.H.; Hallmon W.W.; Mills M.P. Int J Oral Maxillofac Implants, v. 5, n. 1, p. 47-52, 1990.

11. Efeoglu, I.; Arnell, R.D.; Tinston, S.F. Surf Coat Technol, v. 57, n. 1, p. 61-69, 1993.

12. Johansson, C.; Lausmaa, J.; Röstlund, T.; Thomsen, P. J Mater Sc Mater Med, v. 4, n. 2, p. 132-141, 1993.

13. Takadoum, J.; Bennani, H.H. Surf Coat Technol, v. 96, n. 2-3, p. 272-282, 1997.

14. Wilson, S.; Alpas, A.T. Surf Coat Technol, v. 94-95, n. 1-3, p. 53-59, Oct. 1997.

15. Krupa, D.; Basrzkiewicz, J.; Kozubowski, J.A.; Barcz, A.; Sobczak, I.W.; Bilinski, A.; Lewandowska-Szumiel, M.; Rajchel, B. Biomaterials, v. 22, p. 2139-2151, 2001.

16. Dong, H.; Shi, W.; Bell, T. Wear, v. 225-229, p. 146-153, 1999.

17. Itoh, Y.; Itoh, A.; Azuma, H.; Hioki T. Surf Coat Technol, v. 111, p. 172-176, 1999.

18. Guemmaz, M.; Mosser, A.; Grob, J.J. Appl Phys, A 64, p. 407-415, 1997.

19. Pons, F.; Pivin, J.C.; Farges, G. J Mater Res, v. 2, p. 580-587, 1987.

20. Qiu, X.; Conrad, J.R.; Dodd, R.A.; Worzala, F.J. Metall Trans, v. 21, p. 1663-1667, 1990.

21. Venugopalan, R.; George, M.A.; Weimer, J.J.; Lucas, L.C. Biomaterials, v. 20, p. 1709-1716, 1990.

22. Wierzchon, T.; Fleszar, A. Surf Coat Technol, v. 96, p. 205-209, 1997.

23. Salehi, M.; Bell, T.; Morton, P.H. J Phys D: Appl Phys, v. 25, p. 889-895, 1992.

24. Meletis, E.I.; Surf Coat Technol, v. 149, p. 95-113, 2002.

25. Shima, M.; Okado, J.; McColl, I.R.; Waterhouse, R.B.; Hasegawa, T.; Kasaya, M. Wear, v 225-229, p. 38-45, 1999.

26. Wu, P.Q.; Drees, D.; Stals, L.; Celis, J.P. Surf Coat Technol, v. 113, p. 251-258, 1999.

27. Vitchev, R.G.; Blanpain, B.; Celis, J.P. Wear, v. 231, p. 220-227, 1999.

28. Vancoille, E.; Banpain, B.; Xingpu, Y.; Celis, J.P.; Roos, J.R. J Mater Res, v. 9, p. 992-998, 1994.

29. Shenhar, A.; Gotman, I.; Radin, S.; Ducheyne, P.; Gutmanas, E.Y. Surf Coat Technol, v. 126, p. 210-218, 2000.

30. Yilbas, B.S.; Shuja, S.Z. Surf Eng, v. 16, p. 519-523, 2000.

31. L'Enfant, H.; Laurens, P.; Sainte Catherine, M.C.; Dubois, T.; Amouroux, J. Surf Coat Technol, v. 96, p. 169-175, 1997.

32. Labudovic, M.; Kovacevic, R.; Kmecko, I.; Chan, T.I.; Blecic, D.; Blecic, Z. Metall Mater Trans, A 30, p. 1597-1603, 1999.

33. Rodrigo, M.T.; Jiménez, C.; Vázquez, L.; Alonso, F.; Fernández, M.; Martínez-Duart, J.M. J Mater Res, 1998; v. 13, p. 2117-2122, 1998.

34. Santos, C.A. Ion nitriding, Cooperativa Cultural da UFRN, Natal, Brazil, 1989 (in Portuguese).

35. Hudis, M.J. Appl. Phys, v. 44, p. 1489-1492, 1973.

36. Silva, S.L.R.; Kerber, L.O.; Amaral, L.; Santos, C.A. Surf Coat Technol, v. 116-119, p. 342-346, 1999.

37. Rodriguez-Carvajal, J. Physica B, v. 192, p. 55-57, 1993.

38. Kinast, E.J. Structural refinement with the Rietveld method: implementation and essays with the program Fullprof, MSc dissertation (in Portuguese), Instituto de Física - UFRGS, Porto Alegre, Brazil, 2000.

39. Joint Committee on Powder Diffraction Standards. Published by International Centre for Diffraction Data, Swarthmore, Pennsylvania, USA.

40. Feldman, L.C.; Picraux, S.T. Selected low energy nuclear reaction data. In: Mayer, M., Rimini, E., editors. Ion beam handbook for material analysis. London: Academic Press, p. 109-309, 1997.

41. American Society for Testing and Materials, Standard test method for wear testing with a pin-on-disk apparatus, G 99, Philadelphia, USA, 1990.

42. Muraleedharan, T.M.; Meletis, E.I. Thin Solid Films, v. 221, p.104-113, 1992.

43. Hwang, D.H.; Kim, D.E.; Lee, S.J. Wear, v. 225-229, p. 427-439, 1999.

44. Beck, U.; Reiners, G.; Kopacz, U.; Jehn, H.A. Surf Coat Technol, v. 60, p. 389-395, 1993.

45. Badini, C.; Gianoglio, C.; Bacci, T.; Tesi, B. J. Less-Common Metals, v. 143, p.129-141, 1988.

46. Brookshire, F.; Nagy W.W.; Dhuru V.B.; Ziebert G.J.; Chada S. J Prosthet Dent, v. 78, n. 3, p. 286-94, 1997.

Received: November 5, 2002

Revised: February 23, 2003

  • 1. Adell, R.; Eriksson, B.; Lekholh, U.; Brånemark, P.; Jemt, T. Int J Oral & Maxillofac Implants, v. 5, n. 4, p. 347-359, 1990.
  • 2. Brånemark, P.; Zarb, G.; Albrektsson, T. Prótesis tejido-integradas. La osseointegración en la odontologia clínica Quintessenz Verlags-GmbH, Berlin, Germany, p. 350, 1987.
  • 3. Jemt, T.; Lekholm, U.; Adell, R. Int J Oral & Maxillofac Implants, v. 4, n. 3, p. 211-217, 1989.
  • 4. Mezger, P.R.; Creugers, N.H.J. J Dent, v. 20, n. 6, p. 342-344, 1992.
  • 5. Rie, K.; Stucky, T.; Silva, R.A.; Leitão, E.; Bordji, K.; Jouzeau, J.Y.; Mainard, D. Surf Coat Technol, v. 74-75, n. 1-3, p. 973-980, 1995.
  • 6. Wang, K. Mat Science & Eng, A 213, p. 134-137, 1996.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      03 July 2003
    • Date of issue
      June 2003
    ABM, ABC, ABPol UFSCar - Dep. de Engenharia de Materiais, Rod. Washington Luiz, km 235, 13565-905 - São Carlos - SP- Brasil. Tel (55 16) 3351-9487 - São Carlos - SP - Brazil
    E-mail: pessan@ufscar.br