Acessibilidade / Reportar erro

Influence of specimens' design and manufacturing process on microtensile bond strength to enamel: laboratory and FEA comparison

Abstract

This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.

microtensile bond strength; enamel; sample geometry; failure mode; FEA


REGULAR ARTICLES

Influence of specimens' design and manufacturing process on microtensile bond strength to enamel - laboratory and FEA comparison

Fernanda Tranchesi SadekI,* * e-mail: fernandasadek@gmail.com ; Antônio MuenchI; Isis Andréa PoiateII; Edgard Poiate JuniorIII; Paulo Eduardo Capel CardosoI

IDepartment of Dental Materials, University of São Paulo - USP, São Paulo, SP, Brazil

IIDepartment of Operative Dentistry, School of Dentistry, Federal Fluminense University - UFF, Nova Friburgo, Rio de Janeiro, RJ, Brazil

IIIDepartment of Mining and Petroleum Engineering, University of São Paulo - USP, São Paulo, SP, Brazil

ABSTRACT

This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm2 stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPab), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.

Keywords: microtensile bond strength, enamel, sample geometry, failure mode, FEA

1. Introduction

Several mechanical tests, such as shear (microshear), tensile (microtensile) and flexural strength, have been used to measure bond strength of dental substrates and composites, being the microtensile technique, currently, the most used. Since parameters and standardized models were not established for this method, many different procedures for specimen preparation and loading are being followed1, resulting in discrepancies on the data reported by different researchers. As a consequence, the consideration in critically evaluate the microtensile test has risen to overcome some problems associated to it2,3 and also, to turn it in a more reliable, accurate and sensible test1,4-6.

Though the innumerous advantages associated to the microtensile test, specimens' preparation is critical, laborious and technically demanding. It involves sequential cuts into the sample, using predominantly a diamond disc1,7, resulting in thin slabs that can be trimmed or resectioned into beams. Independently on the final shape, sectioning process can introduce stress raisers into the specimen, mainly in enamel, a highly brittle substrate8,9. As a result, high incidences of premature failure and low bond strength values in enamel have frequently being reported2,4,10,11.

Researches in Engineering fields12-14, demonstrated that sectioning with a diamond wire can be an alternative to minimize the introduction of structural defects into brittle specimens. And, recently, the Micro-Specimen Former (University of Iowa, IA, USA) has been employed to standardize the trimming process and could also be an option to avoid additional stress into microtensile specimens15. Their effects, however, in enamel microtensile specimens, should be better evaluated.

Finite element analysis (FEA) of stress distribution has been used to study the sensitivity of bond strengths to specimen design, and changes in testing conditions5,16. Even though, the effect of specimen size, geometry and manufacturing process in the results of bond strength has been partially studied17,18, most studies are focused in the dentin substrate6,19-21. To the best of the author's knowledge, there is scattered peer-reviewed information specific on microtensile enamel's specimen and to date potential effects, on enamel microtensile bond strength, of the difference between diamond wire or disc and stick or dumbbell-shaped specimens are unknown. This raises concern on whether a particular manufacturing process or specimen design could be more appropriate for measurement of the microtensile bond strength on enamel. The null hypothesis was that there is no difference in microtensile bond strength on enamel irrespective of the type of test and specimen manufacturing process.

2. Material and Methods

Thirty caries- and defects- free human third molars were collected after the patients' informed consent that had been obtained under a protocol reviewed and approved by the Ethical Research Committee of the University of São Paulo, Brazil (protocol number 113/07). Some of the most superficial enamel was abraded from the vestibular aspect of the tooth with a 180-grit silicon carbide sand paper under running water to create an enamel flat surface, supported by the underlying dentin; however without exposing it.

The exposed surfaces were acid etched with 37% phosphoric acid for 15 seconds (Total-Etch®, Ivoclar-Vivadent, Schaan, Liechstein), thoroughly rinsed and dried until the enamel surface appeared chalky. Subsequently, the adhesive system (Excite®, Ivoclar-Vivadent) was applied as recommended by the manufacturer and light-cured for 20 seconds. A composite resin block (Tetric Ceram®, Ivoclar-Vivadent) of approximately 5 × 5 × 5 mm was built on the bonding surface, following the incremental technique. Each layer of composite was individually cured for 40 seconds, with an Optilux® 501 light (Demetron®/Kerr, Danbury, CT - USA) with an output of 600 mW.cm-2.

The bonded specimens were stored in a saline solution at 37 °C for 24 hours before being sectioned. Teeth were randomly divided into 3 groups (n = 10): Group 1 - teeth were cut with a diamond disc (Extec® Technologies Inc., Enfield, CA - USA) and Group 2 - teeth were cut using a diamond wire (Well Diamond Wire Saws, Le Locle - Switzerland), in order to obtain stick-shaped specimens with a cross-sectional area of 0.8 mm2. Both cutting procedures were done under continuous water-cooling. Group 3 - teeth were cut initially with a diamond disc (Extec®) into stick-shaped specimens with 2.5 × 2.5 mm that were then trimmed with a cylindrical super fine diamond bur (FG755SF, Kerr-Hawe, Bioggio - Switzerland) mounted on a high-speed handpiece under air-spray, mounted in a Micro-Specimen Former, following the protocol proposed by Armstrong and co-workers15 (Figure 1). The narrowest portion was located at the bonding interface, obtaining dumbbell-shaped specimens with a bonding area of 0.8 mm2.


The incidence of premature failures was calculated for each group. Five specimens from each group were randomly selected for microscopy evaluation. They were previously observed under a Laser Scanning Confocal Microscope (LCM) (Carl Zeiss® Laser Scanning Systems - LSM510, META, Germany) with an excitation wavelength of 488 nm and an emission filter LP 505 nm. After this previous analysis, specimens were dehydrated with ascending alcohol concentrations (30, 50, 70, 90 and 100%) and dried in a hermetic sealed vial with silica. Each specimen was then mounted on aluminum stubs, sputter-coated with gold-palladium (Edwards® Coater S150B, Edwards Ltd., London, UK), and observed under a SEM (Philips® 515, Philips, Eindhoven, the Netherlands). Images taken at relatively low magnifications (25 x - 100 x) provided an overview of the superficial morphology of each specimen, whereas with high magnification views (250 x - 1000 x) defects, microcracks, scratches and wrenches were visualized.

Remaining samples had their cross-sectional areas carefully measured to the nearest 0.01 mm with a digital caliper. For groups 1 and 2, a cyanoacrylate material (Super Bonder® Gel, Loctite) was used to bond the ends of each specimen on the grip of a Geraldeli's device 22. Specimens for group 3 were placed in a Dircks' device15. Both devices were mounted on a universal loading machine (Instron model 5565, Instron® Corporation Headquarters, Canton, MA, USA) and tensile load rate was applied at a crosshead speed of 1 mm/min, until the fracture of the specimen occurred. Bond strength data were considered per tooth in order to take into account the tooth-related variance (n = 10) and specimens with premature bond failures were not included in the compilation of the mean. Then, the statistical analysis of the influence of specimens' design and manufacturing process was performed with an one-way ANOVA, followed by an all pair-wise multiple comparison post-hoc test (Tukey test). Statistical significance was set in advance at the 0.05 of probability level.

The mode of failure of each specimen was determined using the SEM (Philips® 515) in a secondary electron and back-scattered mode and classified as cohesive in composite resin - type 1; cohesive in enamel - type 2; adhesive - type 3 and mixed - type 4.

Three-dimensional FEA models were developed using the program MSC/PATRAN® 2005 (MSC.Software Corporation, Santa Ana, CA, USA) in the pre-processing, post-processing for visualization and evaluation of the results. The processing stage or the solution analysis was performed with the program MSC/NASTRAN 2005 (MSC.Software Corporation, Santa Ana, CA, USA). 3D solid model geometry representing each component or substrate was designed and assembled following the procedures recently described by Poiate and co-authors 23. The modeled specimens were assumed with 10.01 mm in height and 0.8 mm2 in cross-sectional area (Figure 2). Due to the symmetry in two planes, only one quarter of the specimen was simulated. The analysis for the two models was run with a bonding agent layer thickness of 10 μm24. All the structures in these models assumed to be linearly elastic behavior, isotropic and homogeneous, characterized by two physical properties: Young's Modulus (E) and Poisson's Ratio (ν) of dentin, enamel, adhesive, and resin composite, were, respectively: 18.6 GPa/0.31, 41 GPa/0.30, 4 GPa/0.35 and 9.4 GPa/0.3824, 25. The interfaces between the structures were presumed to be perfectly bonded. Tetrahedral element topology (Tet4) was applied. The degree of discretization was established from convergence studies and the m-method of finite element refinement ensured that a proper FE model mesh density was generated. The dumbell model resulted in 33481 nodal points and 194766 elements and the stick model in 15940 nodal points and 92277 elements.


The boundary conditions of the models were the same of the experimental tests, thus, in the stick model, the constraints were applied over the surfaces (posterior, anterior and lateral) of dentin and resin composite to simulate the test where the specimen was attached with glue in the Geraldeli's device, with a free central length of 3.51 mm. In the resin composite side, no rotation and no translation were applied and in the dentin side, just the translation along the symmetry axis was allowed. In the dumbbell model, the constraints (no rotation and no translation) were applied over the neck and shoulder in the resin composite side and in dentin side, just the translation along the symmetry axis was allowed, with a free central length of 3.01 mm, to simulate the specimen attached in the Dircks' device.

Considering the load conditions in the experiment (1 mm/min) the applied load at the numerical models was static, suitable for the conditions tested. The static load applied in the models was the average value obtained in the experiments tests with stick (32.30 N) and dumbbell model (17.46 N), divided equally for the number of nodes existent in the application areas. In the stick model the load was applied perpendicular to the upper dentin surface and parallel to the symmetry axis at the dentin neck and shoulder area in the dumbbell model (region where the device was attached), simulating the experimental set-up during microtensile test. The symmetry boundary conditions were applied in two surfaces in both models. The maximum principal stress (MPS) was used as the stress criterion to present the stress patterns distribution for each model and the dentin, enamel and adhesive's tensile strength of 10326, 16.726 and 27 MPa5, respectively, were used as reference for results comparison.

3. Results

3.1. Microtensile bond strength test and premature failure incidence

The mean and standard deviation microtensile bond strength data are summarized in Figure 3. One-way ANOVA and Tukey's test revealed statistically significant differences between the three groups (p < 0.05). The bond strength value for the stick-shaped design cut with wire (42.93 ± 4.77 MPa)ª was higher than the stick-shaped design sectioned with disc (36.62 ± 3.63 MPa)b, which was also higher than dumbbell-shaped specimens (21.83 ± 5.44 MPa)c. Differences were also found in the incidence of premature failures. It was low when sectioning with wire (5.4%), almost four times higher when sectioning with disc (20.0%) and approximately six times higher when trimmed as a dumbbell (31.8%).


3.2. Results of LCM and SEM integrity analysis

The LCM analyze demonstrated structural defects in the stick-shaped specimens sectioned with the diamond disc and irregularities in the dumbbell-shaped specimens, while the ones cut with wire presented a flawless structural integrity (Figure 4a-c). SEM analyze corroborated to these finds. Structural defects, like cracks, scratches and wrenches were commonly observed in stick-shaped specimens sectioned with disc. Even though dumbbell-shaped specimens did not show structural defects, it was not possible to observe perfectly cylindrical trimmed interfaces (Figure 4d-f).


3.3. Mode of failure

The failure modes of debonded specimens are reported in Table 1 and examples of common modes of failure are illustrated in Figure 5. Type 4, mixed failure, was the predominant mode of failure in all groups. However, the results revealed that the primary failure site among the three groups was at the enamel border. A very small number of specimens displayed a total cohesive failure within the adhesive material (type 3) and no cohesive failure within the resin composite was recorded (type 1). For groups 1 and 3 a large number of specimens showed cohesive failure in enamel (type 2), especially with the stick-shaped specimens cut with disc.


3.4. FEA results

The MPS distribution from FEA in stick and dumbbell models is presented in Figure 6 in lateral, central and in perspective views. The geometry design and the boundary conditions had a significant influence on stress concentration and distribution. The dumbbell model resulted in more homogeneous stress distribution than the stick model along the testing region, due to circular cross section against the square. Maximum stresses were located near the neck in the dumbbell model (38 to 40 MPa) and concentrated at the sharp corner in the stick model (45 to 62 MPa), exceeding the adhesive's tensile strength. In both models dentin's tensile strength was not reached, while enamel's tensile strength was exceed, and reached 25 to 30 MPa in the dumbbell-shaped model and up to 62 MPa in the stick-shaped model.


Figure 7 shows the MPS along the symmetry line. The minimum stress in the stick model was 36 MPa and the maximum stress was 43 MPa, while in the dumbbell model was 0 and 23 MPa, respectively. The curve shape of each model was different due to the boundary conditions that each model was submitted.


4. Discussion

Results of the current study revealed that microtensile bond strength in enamel was dependent on specimen designs and manufacturing process, though the null hypothesis should be rejected. Stick-shaped specimens sectioned with a diamond wire showed a significant higher bond strength values (Figure 3), lower incidence of premature failure and cohesive failure in enamel (Table 1) and better a structural integrity of the specimens before being tested (Figure 4). This suggested that sectioning with wire, when bonding is done in enamel, is more reliable compared to stick-shaped specimens cut with a diamond disc and dumbbell-shaped specimens.

The lower bond strength and higher incidence of premature failure and structural defects in enamel associated with stick-shaped specimens sectioned with the diamond disc can be related to the elevated elastic modulus (80.3 ± 7.7 GPa) and low fracture toughness (0.8 MPa.m1/2) of this brittle substrate9,27. Both properties demonstrate nucleation facility and crack propagation when enamel is stressed. Stress concentration is effective upon contact loading, and the probability of encountering flaws into sectioned specimens increases with increasing dimensions of the contact area. As already demonstrated, contact area of wire saws is about an order of magnitude smaller compared to that of high-end super thin saw blades12. It should be pointed out that this enamel friability was exacerbated due to the reduced areas of stick-shaped specimens used in this study.

Generally, stick-shaped specimens are easier to prepare with a more consistent outline, as observed in this study. Trimming is very technique sensitive1, mainly in enamel, and it increases the chance of damaging the specimens by creating defects, flaws and additional stress6,18, facilitating premature failures. In addition, even though the trimming process in this study was done with the Micro-Specimen Former, milling progress movements were done freehand. For this reason, it was difficult to consistently produce a perfectly cylindrical outline at the bonded interface (Figures 4a and d) and the negative effect of additional trimming was observed. When Ghassemieh simulated a flaw both at the edge and in the middle of the adhesive interface, he found that the percentage of chance in maximum stresses was in order of 30 - 50% and it was concentrated at the tip of the flaw5. The high-stress areas at the tip of the crack are oriented toward the interface, which results in progression of the crack. Since dumbbell-shaped specimens is in need of bur diamond trimming at the edges, the possibility of creating such a flaw at the edge of the sample is higher.

LCM and SEM results were coherent to the microtensile bond strength data collected, showing the undesirable and deleterious effect that cutting equipment and/or specimens' shape could induce to microtensile specimens in enamel (Figure 4). Structural defects and irregularities were found more frequently in groups with lower bond strength values (stick-shaped specimens cut with saw and dumbbell-shaped specimens), so can be hypothesized that these defects undermining their integrity, being responsible for their failure under relatively low loading levels and for their higher incidence of premature failure. A rapid propagation to the interface of a defect nucleated in the enamel substrate may be again a possible explanation of this phenomenon28. Moreover, the mode of failure analysis substantiated with this hypothesis, since most primary failure sites among these groups were at the enamel border (Figure 5).

It could be questioned if these SEM defects found would not be related to SEM artifacts, due to desiccation during sample preparation and/or vacuum process. Nonetheless, it may be elucidated that LCM analysis also demonstrated these structural defects (Figure 4a and c), even though confocal microscopy provides the capacity for direct, noninvasive, serial optical sectioning of intact specimens with a minimum of sample preparation and no vacuum is needed. Moreover, stick-shaped specimens cut with wire underwent through the same sample preparations and vacuum for SEM and presented a flawless structural integrity (Figure 2e).

The two designs used in the study were modeled to evaluate the influence of the geometry of microtensile specimens on the stress developed across the adhesive interface. FEA is a useful approach to help understand structural behavior under load17,19,20. In the two FEA models studied, the maximum principal stress (MPS) was selected to illustrate the stress generated at the adhesive interface and the stress distribution observed in our FEA models were in agreement with a previous work 5. The maximum stress for the dumbbell design was in the center and decreased to the extremities, due to its geometry (cylindrical shape) and how it was loaded (Figure 7). Strengths converge to the central region of the model, which is the ideal condition to evaluate a structural behavior of adhesive interfaces. Opposite to that, stick-shaped specimen concentrated the maximum stress at the sharp corner. The average stress evaluated from the rupture load divided by the cross section area was lower than the real failure stress, due to stress concentration. In the edges of stick model it was around 44%, whilst in the dumbbell model the difference was around 27% (Figure 6).

Since FEA showed that there were significant differences in the stress concentration and distribution between the two designs (Figure 6), different bond strength values should be expected. Actually, different bond strength values were found, however, in an opposite way. The stress concentration at the interface in the dumbbell model was smaller compared to stick-shaped model, nevertheless, lower bond strength values were also observed.

The failure stress predicted by FEA is on the basis of assumption that the strengths of the interfaces are equal to the strength of the adhesive and the interfaces between the structures are perfectly bonded. However, there has been no experimental work to support these assumptions. And this could only be valid if the laboratory samples were all perfectly made and are free from flaws, which was rarely obtained, justifying opposite results found. Cracks induced at the edge of the sample during manufacturing process were clearly seen in the microscopy analysis when stick-shaped specimens were cut with the blade and imperfect interface were observed in dumbbell-shaped specimens (Figure 4). As also observed in a recent published research6, even though trimming process was done with the Micro-Specimen Former, unperfected cylindrical interfaces were observed for the dumbbell-shaped specimens.

Within the limitations of this study, it could be concluded that, theoretically, dumbbell-shaped specimens distribute more uniformly the stress due to their cylindrical geometry and boundary conditions. However, they should only be indicated to evaluate bond strength in enamel if manufacturing process would be improved (like CAD-CAM® process) to reduce imperfections into the interface. Awaiting it would be possible, stick-shaped, nontrimmed specimens sectioned with diamond wire are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.

Acknowledgments

This study was supported by FAPESP (process 2005/60644-2).

Received: February 9, 2010

Revised: April 22, 2010

  • 1. Pashley DH, Carvalho RM, Sano H, Nakajima M, Yoshiyama M, Shono Y, et al. The microtensile bond test: a review. Journal of Adhesive Dentistry (Carol Stream), 1999; 1(4):299-309.
  • 2. Sadek FT, Cury AH, Monticelli F, Ferrari M and Cardoso PE. The influence of the cutting speed on bond strength and integrity of microtensile specimens. Dental Materials (Kidlinton), 2005; 21(12):1144-1149.
  • 3. Goracci C, Tavares AU, Fabianelli A, Monticelli F, Raffaelli O, Cardoso PC, et al. The adhesion between fiber posts and root canal walls: comparison between microtensile and push-out bond strength measurements. European Journal of Oral Science (Malden). 2004; 112(4):353-361.
  • 4. de Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, et al. A critical review of the durability of adhesion to tooth tissue: methods and results. Journal of Dental Research (Washington, DC), 2005; 84(2):118-132.
  • 5. Ghassemieh E. Evaluation of sources of uncertainties in microtensile bond strength of dental adhesive system for different specimen geometries. Dental Materials (Kidlinton), 2008; 24(4):536-547.
  • 6. Poitevin A, De Munck J, Van Landuyt K, Coutinho E, Peumans M, Lambrechts P, et al. Critical analysis of the influence of different parameters on the microtensile bond strength of adhesives to dentin. Journal of Adhesive Dentistry (Carol Stream), 2008; 10(1):7-16.
  • 7. Shono Y, Ogawa T, Terashita M, Carvalho RM, Pashley EL and Pashley DH. Regional measurement of resin-dentin bonding as an array. Journal of Dental Research (Washington, DC), 1999; 78(2):699-705.
  • 8. Arikawa H. Dynamic shear modulus in torsion of human dentin and enamel. Dental Materials Journal (Kdlinton), 1989; 8(2):223-235.
  • 9. Mahoney E, Holt A, Swain M and Kilpatrick N. The hardness and modulus of elasticity of primary molar teeth: an ultra-micro-indentation study. Journal of Dentistry (Bristol), 2000; 28(8):589-594.
  • 10. de Munck J, Van Meerbeek B, Satoshi I, Vargas M, Yoshida Y, Armstrong S, et al. Microtensile bond strengths of one- and two-step self-etch adhesives to bur-cut enamel and dentin. American Journal of Dentistry (San Antonio), 2003; 16(6):414-420.
  • 11. van Meerbeek B, De Munck J, Mattar D, Van Landuyt K and Lambrechts P. Microtensile bond strengths of an etch&rinse and self-etch adhesive to enamel and dentin as a function of surface treatment. Operative Dentistry (Washington, DC), 2003; 28(5):647-660.
  • 12. Clark WI, Shih AJ, Hardin CW, Lemaster RL and McSpadden SB. Fixed abrasive diamond wire machine - part I: process monitoring and wire tension force. International Journal of Machines Tools & Manufacturing (New York), 2003; 43(3):523-532.
  • 13. Ito S and Murata R. Study on machining characteristics of diamond abrasive wire. Journal of Mechanical Engeneering Laboratory (Tokyo), 1987; 41(5):236-244.
  • 14. Tokura H, Nakayama S and Yoshikawa M. Cutting performance of diamond plated wire tools. International Journal of the Japan Society for Precision Engeneering (Tokyo), 1992; 58(12):2013-2018.
  • 15. Armstrong SR, Keller JC and Boyer DB. Mode of failure in the dentin-adhesive resin-resin composite bonded joint as determined by strength-based (muTBS) and fracture-based (CNSB) mechanical testing. Dental Materials (Kidlinton), 2001; 17(3):201-210.
  • 16. Soares CJ, Soares PV, Santos-Filho PC and Armstrong SR. Microtensile specimen attachment and shapefinite element analysis. Journal of Dental Research (Washington, DC). 2008; 87(1):89-93.
  • 17. Phrukkanon S, Burrow MF and Tyas MJ. The influence of cross-sectional shape and surface area on the microtensile bond test. Dental Materials (Kidlinton), 1998; 14(3):212-221.
  • 18. Goracci C, Sadek FT, Monticelli F, Cardoso PE and Ferrari M. Influence of substrate, shape, and thickness on microtensile specimens' structural integrity and their measured bond strengths. Dental Materials (Kidlinton), 2004; 20(7):643-654.
  • 19. Betamar N, Cardew G and Van Noort R. The effect of variations in hourglass specimen design on microtensile bond strength to dentin. Journal of Adhesive Dentistry (Carol Stream), 2007; 9(5):427-436.
  • 20. Betamar N, Cardew G and Van Noort R. Influence of specimen designs on the microtensile bond strength to dentin. Journal of Adhesive Dentistry (Carol Stream), 2007; 9(2):159-168.
  • 21. Silva NR, Calamia CS, Harsono M, Carvalho RM, Pegoraro LF, Fernandes CA, et al. Bond angle effects on microtensile bonds: Laboratory and FEA comparison. Dental Materials (Kidlinton), 2006; 22(4):314-324.
  • 22. Perdigao J, Geraldeli S. Bonding characteristics of self-etching adhesives to intact versus prepared enamel. Journal of esthetic and restorative dentistry (Hamilton), 2003; 15(1):32-41.
  • 23. Poiate IA, Vasconcellos AB, Andueza A, Pola IR and Poiate Jr. E. Three dimensional finite element analyses of oral structures by computerized tomography. Journal of Bioscience and Bioengeneering (Osaka), 2008; 106(6):606-609.
  • 24. Ausiello P, Rengo S, Davidson CL and Watts DC. Stress distributions in adhesively cemented ceramic and resin-composite Class II inlay restorations: a 3D-FEA study. Dental Materials (Kidlinton), 2004; 20(9):862-872.
  • 25. Ko CC, Chu CS, Chung KH and Lee MC. Effects of posts on dentin stress distribution in pulpless teeth. Journal of Prosthetic Dentistry (Saint Louis), 1992; 68(3):421-427.
  • 26. Tanaka M, Naito T, Yokota M and Kohno M. Finite element analysis of the possible mechanism of cervical lesion formation by occlusal force. Journal of Oral Rehabilitation (Oxford), 2003; 30(1):60-67.
  • 27. Dong XD and Ruse ND. Fatigue crack propagation path across the dentinoenamel junction complex in human teeth. Journal of Biomedical Material Research Part A (Hoboken), 2003; 66(1):103-109.
  • 28. Callister WDJ. Materials science and engineering: an introduction. New York: Wiley and Sons; 1994.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      16 July 2010
    • Date of issue
      June 2010

    History

    • Accepted
      22 Apr 2010
    • Received
      09 Feb 2010
    ABM, ABC, ABPol UFSCar - Dep. de Engenharia de Materiais, Rod. Washington Luiz, km 235, 13565-905 - São Carlos - SP- Brasil. Tel (55 16) 3351-9487 - São Carlos - SP - Brazil
    E-mail: pessan@ufscar.br