Acessibilidade / Reportar erro

Photodegradation Mechanisms on Poly(ε-caprolactone) (PCL)

Abstract

Photodegradation of PCL was performed exposing injected specimens to ultraviolet radiation (UV-B) up to 9 weeks. Photodegradated PCL specimens were tested by Differential Scanning Calorimetry (DSC), Infrared Spectroscopy (FTIR), mechanical properties, Optical Microscopy (MO) and Scanning Electron Microscopy (SEM).Upon exposure decrease in elongation at break and increase of elastic modulus were verified, higher degree of crystallinity was observed for longer exposure what can be due to the chemi-crystallization mechanism. From IR spectra new carbonyl group (C=O) peaks were observed. Presence of micro cracks on specimens’ surface was identified by MO. From morphological analyses is suggested that the photodegradation in PCL takes place by bulk erosion mechanism.

Key-words:
PCL; Phododegradation; Chemi-crystallization; Bulk erosion


1. Introduction

Synthetic plastics have been used for various purposes, especially in the packaging industrial sector; however, the majority of these materials presently cause serious problems with the waste management 11 Bastioli C, ed. Handbook of Biodegradable Polymers. Shawbury: Rapra Technology; 2005.

2 Mohanty AK, Misra M, Drzal LT, eds. Natural Fibers, Biopolymers, and Biocomposites. Singapore: Taylor & Francis; 2005.

3 Biron M. The Plastics Industry: Economic Overwiew. In: Biron M. Thermosets and Composites - Material Selection, Applications, Manufacturing and Cost Analysis. 2nd ed. Amsterdam: William Andrew; 2014. p. 25-104.
-44 Emblem A. Plastics Properties for Packing Materials. In: Emblem A, ed. Packing Technology - Fundamentals, Materials and Processes. Oxford: Woodhead Publishing; 2012. p. 287-309.. Focusing on potential solutions for this problem, polymer researchers have paid attention to biodegradable polymers, from petroleum and renewable sources, since they can be biologically degraded and therefore being considered as environmental friendly materials 55 Van Hung N, De Schryver P, Tam TT, Garcia-Gonzalez L, Bossier P, Nevejan N. Application of poly-ß-hydroxybutyrate (PHB) in mussel larviculture. Aquaculture. 2015;446:318-324.

6 Li X, Qi C, Han L, Chu C, Bai J, Guo C, et al. Influence of dynamic compressive loading on the in vitro degradation behavior of pure PLA and Mg/PLA composite. Acta Biomaterialia. 2017;64:269-278.

7 Sungkapreecha C, Iqbal N, Gohn AM, Focke WW, Androsch R. Phase behavior of the polymer/drug system PLA/DEET. Polymer. 2017;126:116-125.

8 Laycock B, Nikolic M, Colwell JM, Gauthier E, Halley P, Bottle S, et al. Lifetime prediction of biodegradable polymers. Progress in Polymer Science. 2017;71:144-189.

9 Wachirahuttapong S, Thongpin C, Sombatsompop N. Effect of PCL and Compatibility Contents on the Morphology, Crystallization and Mechanical Properties of PLA/PCL Blends. Energy Procedia. 2016;89:198-206.

10 Hsu ST, Tan H, Yao YL. Effect of excimer laser irradiation on crystallinity and chemical bonding of biodegradable polymer. Polymer Degradation and Stability. 2012;97(1):88-97.

11 Badia JD, Gil-Castell O, Ribes-Greus A. Long-term properties and end-of-life of polymers from renewable resources. Polymer Degradation and Stability. 2017;137:35-57.
-1212 Wang Y, Pan J, Han X, Sinka C, Ding L. A phenomenological model for the degradation of biodegradable polymers. Biomaterials. 2008;29(23):3393-3401. .

Among the biodegradable polymers, a special attention has been given by the scientific community to poly(ε-caprolactone) (PCL), that is a linear aliphatic semicrystalline polyester, synthesized by ring-opening polymerization of the cyclic lactone in presence of a catalyst. PCL has high ductility due to its chemical structure and low glass transition temperature of -60 ºC, it is thermally stable until 320 ºC, as a thermoplastic it is easily processed and recycled by conventional polymer processing, i.e., extrusion and injection 1212 Wang Y, Pan J, Han X, Sinka C, Ding L. A phenomenological model for the degradation of biodegradable polymers. Biomaterials. 2008;29(23):3393-3401.

13 Abdel-Rehim HA, Yoshii F, Kume T. Modification of polycaprolactone in the presence of polyfunctional monomers by irradiation and its biodegradability. Polymer Degradation and Stability. 2004;85(1):689-695.

14 Zhao Q, Tao J, Yam RCM, Mok ACK, Li RKY, Song C. Biodegradation behavior of polycaprolactone/rice husk ecocomposites in simulated soil medium. Polymer Degradation and Stability. 2008;93(8):1571-1576.
-1515 . De Paoli MA. Degradação e Estabilização de Polímeros. 2ª versão on-line. Chemkeys; 2008. Available from: < http://www.chemkeys.com/blog/wp-content/uploads/2008/09/polimeros.pdf>. Access in: 30/1/2018.
http://www.chemkeys.com/blog/wp-content...
. PCL has been successful used in a wide range of industrial applications, including packing, food containers, agricultural films, biomedical applications, devices for automobile and electronic industries, and so on 1616 Copinet A, Bertrand C, Govindin S, Coma V, Couturier Y. Effects of ultraviolet light (315 nm), temperature and relative humidity on the degradation of polylactic acid plastic films. Chemosphere. 2004;55(5):763-773.

17 França DC, Bezerra EB, Morais DDS, Araújo EM, Wellen RMR. Hydrolytic and Thermal Degradation of PCL and PCL/Bentonite Compounds. Materials Research. 2016;19(3):618-627.
-1818 Bhullar SK, Rana D, Lekesiz H, Bedeloglu AC, Ko J, Cho Y, et al. Design and fabrication of auxetic PCL nanofiber membranes for biomedical applications. Materials Science and Engineering: C. 2017;81:334-340..

Nevertheless, to the best of our knowledge few works are dealt about the photodegradation of PCL. Tsuji et al. 1919 Tsuji H, Echizen Y, Nishimura Y. Photodegradation of biodegradable polyesters: A comprehensive study on poly(l-lactide) and poly(ɛ-caprolactone). Polymer Degradation and Stability. 2006;91(5):1128-1137. suggested that photodegradation of PCL films proceeds via a bulk erosion mechanism with serious damages to the elongation at break, they observed that the effects are deeper in the amorphous phases; and the UV irradiation significantly increased the degree of crystallinity of PCL due to thickening of crystallites. Photodegradation of PCL was delayed upon blending with PVC as observed by Christensen et al. (2008) 2020 Christensen PA, Egerton TA, Franchetti SM, Jin C, White JR. Photodegradation of polycaprolactone/poly(vinyl chloride) blend. Polymer Degradation and Stability. 2008;93(1):305-309..Bei et al. (2000) 2121 Bei J, He W, Hu X, Wang S. Photodegradation behavior and mechanism of block copoly(caprolactone-ethylene glycol). Polymer Degradation and Stability. 2000;67(2):375-380. verified in poly(ε-caprolactone)-poly(ethylene glycol) block copolymer (PCE) that the pure poly(ethylene glycol) (PEO) cannot be photodegraded alone, but the carbonyl groups in PCL segment catalyze the breakage of PEO chains by a series of UV initiated free radical reactions.

In this work inject specimens of PCL were photodegraded by exposure to UV-B radiation, and their morphology, thermal and mechanical properties properly analyzed by optical microscopy (OM), scanning electron microscopy (SEM), differential scanning calorimetry (DSC), infrared spectroscopy (FTIR) and mechanical properties. According to the DSC results further presented the chemi-crstallization process is suggested taking place and being the responsible for increasing the degree of crystallinity, and the photodegradation in PCL was evidenced by SEM images as occurring by bulk erosion mechanism.

2.Experimental

2.1 Materials

Poly (ɛ-caprolactone) (PCL) CAPA 6500, melting flow rate (MFR) = 28 g/10 min (190 °C/2.16 kg), was purchased from Perstorp Winning Formulas.

2.2 Processing

Neat PCL was processed in a twin screw extruder Coperion-Werner&Pfleiderer ZSK 18. The temperature inside the extruder was kept between 80 °C and 100 °C and the screw speed was set up at 250 rpm. After extrusion, the material was granulated and oven dried for 24 hours at 40 ºC. Injected specimens for mechanical experiment were produced in Arburg Allrounder 270C machine at 80-100 ºC, according to ASTM D638 standard.

2.3 Radiation exposure

The radiation tests were performed using a Comexim (type C-UV) appropriate for non-metallic materials, operating with 40 W F40 UV-B fluorescent lamps with peak radiation at 313 nm. The samples were exposed to continuous radiation for periods up to 9 weeks, forwarding characterization experiments were performed.

3. Characterization

3.1 Differential scanning calorimetry (DSC)

DSC analyses carried out in a DSC-Q20 TA Instruments, samples weighting approximately 3 mg were heated from 25 ºC to 250 ºC, followed by cooling to 10 °C and reheating to 250 °C. The heating/cooling rate was 10 ºC/min, under nitrogen flow of 50 mL/min.

3.2 Mechanical tests

Mechanical properties in tension were measured according to ASTM D638; tests were conducted in an EMIC DL 2000 testing machine operating at 50 mm/min of elongation rate and 2000 kgf cell load. Tests were conduct at ambient temperature (~ 23 ºC) and presented results are an average of seven tests.

3.3 Fourier transformed infrared spectroscopy (FTIR)

FTIR analyses were performed in a Perkin Elmer Spectrometer Spectrum 400 FT Mid-IR, Attenuated Total Reflectance (ATR) mode was applied and scans ranging from 4000 to 650 cm-1 were computed.

3.4 Polarized optical microscopy (OM)

Photographs of PCL before and after exposure were recorded on a Carl Zeiss Polarized Optical Microscope equipped with a digital camera, AxioCAM MRc.

3.5 Scanning electron microscopy (SEM)

Scanning electron microscopy images were acquired in a VEGAN3 TESCAN machine with 30 KV. Fractured surface from mechanical test was covered with gold to avoid accumulation of charges.

4. Results and Discussion

Photographs of PCL specimens unexposed and exposed to UV-B radiation up to 9 weeks are illustrated in Figure 1. After exposure, there is light-yellowing on exposed specimen surface and micro cracks developed with exposition to radiation (Figure 1 from 1 week). According to the literature 1515 . De Paoli MA. Degradação e Estabilização de Polímeros. 2ª versão on-line. Chemkeys; 2008. Available from: < http://www.chemkeys.com/blog/wp-content/uploads/2008/09/polimeros.pdf>. Access in: 30/1/2018.
http://www.chemkeys.com/blog/wp-content...
the yellowing is evidence that photodegradation is taking place, its origin may be accessed to radiation absorption by chromophoric groups and formation of free radicals that absorb oxygen and start chemical and physical changes like chain scission, damaging the mechanical properties.

Figure 1
Photographs of PCL specimens illustrating light-yellowing after UV-B exposure. Exposing times in weeks are indicated

The texture of the specimen exposed surface becomes rougher and crumbles for longer exposure times. The presence of cracks and roughness in samples exposed to radiation has already been reported for other polymers like poly(3-hydroxybutyrate) (PHB), polyvinyl chloride (PVC), polystyrene (PS), polypropylene (PP) 11 Bastioli C, ed. Handbook of Biodegradable Polymers. Shawbury: Rapra Technology; 2005.,1313 Abdel-Rehim HA, Yoshii F, Kume T. Modification of polycaprolactone in the presence of polyfunctional monomers by irradiation and its biodegradability. Polymer Degradation and Stability. 2004;85(1):689-695.,1414 Zhao Q, Tao J, Yam RCM, Mok ACK, Li RKY, Song C. Biodegradation behavior of polycaprolactone/rice husk ecocomposites in simulated soil medium. Polymer Degradation and Stability. 2008;93(8):1571-1576.,2222 Rabello MS, White JR. The role of physical structure and morphology in the photodegradation behaviour of polypropylene. Polymer Degradation Stability. 1997;56(1):55-73.,2323 Rabello MS, White JR. Crystallization and melting behaviour of photodegraded polypropylene - II. Re-crystallization of degraded molecules. Polymer. 1997;38(26):6379-6387..

Wellen et al.2424 Wellen RMR, Canedo EL, Rabello MS, Fechine GJM. Photodegradation and Photostabilization of Poly(3-Hydroxybutyrate). Materials Research. 2016;19(4):759-764. studied the photodegradation and photostabilization of two commercial grades of PHB. The authors obtained the specimens by injection molding and the specimens were exposed to ultraviolet radiation (UV-A) for up to 12 weeks and then characterized by tensile testing, surface appearance, size exclusion chromatography (SEC) and scanning electron microscopy (SEM). According to the authors the exposure to UV-B radiation caused great damage on the surface color, reduction of molecular size and mechanical properties. However, it is important to note that for PHB changes in color can be not caused by chromophoric groups but by cracks on the specimen surface that increase its roughness and the diffuse reflectance of visible light.

Regarding the superficial changes originated upon exposition to radiation, according to Rabello and White2222 Rabello MS, White JR. The role of physical structure and morphology in the photodegradation behaviour of polypropylene. Polymer Degradation Stability. 1997;56(1):55-73. an important process called chemi-crystallization is observed in some semi-crystalline polymers, for instance in PP. In chemi-crystallization the chain scission occurs due to the degradation mechanism but these broken molecules reorganize in a crystalline phase, provided that they have enough mobility. The main characteristic of this process is the spontaneous crack formation on external surfaces by the contraction of the specimen layers, these cracks contribute to the embrittlement of ductile semi-crystalline polymers promoting serious deterioration on polymer after short exposure.

Figure 2 shows DSC scans for melt crystallization and melting of PCL unexposed and exposed up to 9 weeks, and Tables 1 and 2 present thermal parameters computed from these scans. It is observed that the crystallization peak shifted lightly to higher temperatures, the degree of crystallinity (ΔXC) decreased upon exposure. An interesting fact observed for 9 weeks of exposure is that the crystallinity was higher than for shorter intervals of exposure, somehow PCL molecular chains rearranged and crystallized, it may be seen as an effect of chemi-crystallization.

Figure 2
DSC scans for Melt Crystallization (left) and Melting (right), acquired during cooling and re-heating cycles, respectively

Table 1
Melt crystallization parameters computed from DSC scans during cooling for PCL exposed to UV-B radiation up to 9 weeks.
Table 2
Melting parameters computed from DSC scans during the second heating for PCL up to 9 weeks.

The melting peak temperature did not show significant changes, the degree of crystallinity (ΔXm) measured from melting enthalpy presented a similar trend as that verified for melt crystallization, the degree of crystallinity decreased upon exposure and then it increased for longer exposure, i.e., 9 weeks, it also may be an effect of chemi-crystallization.

Polymer studiers have reported decrease in crystallinity upon degradation for other resins like PLA, PET and PEEK 2525 Santonja-Blasco L, Ribes-Greus A, Alamo RG. Comparative thermal, biological and photodegradation kinetics of polylactide and effect on crystallization rates. Polymer Degradation and Stability. 2013;98(3):771-784.,2626 Vaughan AS, Stevens GC. On radiation effects in poly(ethylene terephthalate): a comparison with poly(ether ether ketone). Polymer. 1995;36(8):1541-1547.. Santonja-Blasco et al.2525 Santonja-Blasco L, Ribes-Greus A, Alamo RG. Comparative thermal, biological and photodegradation kinetics of polylactide and effect on crystallization rates. Polymer Degradation and Stability. 2013;98(3):771-784. investigated the effects of three types of degradation, thermo-degradation, photodegradation and biodegradation in PLA. At high temperature i.e., thermal degradation at 220 °C, random chain scission was faster followed by photodegradation and biodegradation. Photodegraded specimens presented around the half of molar mass compared to soil degraded ones, i.e. biodegraded. Chain defects such as the anhydride groups formed during photodegradation decreased the crystallization rate, but the extreme damages as higher chain scission and lower crystallinity were verified for thermal-degradation.

Vaughan and Stevens2626 Vaughan AS, Stevens GC. On radiation effects in poly(ethylene terephthalate): a comparison with poly(ether ether ketone). Polymer. 1995;36(8):1541-1547. analyzed the effect of gamma radiation on PET crystallization. Sample tests were experimented in amorphous state as well as after annealing. The gathered results were similar to those obtained for PEEK, i.e. as the radiation doses increased, the melt crystallization peak shifted to higher temperatures and the degree of crystallinity decreased.

Figure 3 shows results for elastic modulus (a), elongation at break (b), maximum stress (c) and tensile strength (d) for PCL before and after exposure to UV-B radiation.

Figure 3
PCL mechanical properties before and after exposure. a) Elastic Modulus, b) Elongation at Break, b) Maximum Strength, d) Tensile Strength

Initially, PCL behaves as a ductile polymer, with low elastic modulus and high elongation at break (>418%). After exposure, its elastic modulus increased by 48% and remained almost unchangeable over the exposure time.

For elongation at break, a decrease of 80% was observed after the first week of exposure, in two weeks it decreased 94% in relation to unexposed PCL and 71% to PCL exposed for 1 week. Further exposure did not provide significant changes, specimens presented similar mechanical properties.

These events, increase in elastic modulus and higher decrease in elongation at break that occurred after exposure to radiation, modified PCL properties, making it a rigid and brittle polymer, micro cracks, crazy development as well as chemi-crystallization are processes possibly linked to these changes 88 Laycock B, Nikolic M, Colwell JM, Gauthier E, Halley P, Bottle S, et al. Lifetime prediction of biodegradable polymers. Progress in Polymer Science. 2017;71:144-189..

Figure 4 shows FT-IR spectra of PCL unexposed and exposed. According to the literature 3030 Elzein T, Nasser-Eddine M, Delaite C, Bistac S, Dumas P. FTIR study of polycaprolactone chain organization at interfaces. Journal of Colloid and Interface Science. 2004;273(2):381-387.,3131 Lin-Vien D, Colthup NB, Fateley WG, Grassselli J. The Handbook of Infrared and Raman Characteristic Frequencies of Organic Molecules. London: Academic Press; 1991., PCL presents infrared absorption bands which are relevant for polymer characterization and its changes. The spectra in Figure 4 presented in 2944 cm-1 and 2861 cm-1 referring bands to asymmetric and symmetrical stretching of CH2 groups, respectively. The most intense peak at 1725 cm-1 is characteristic of carbonyl group C=O, the peak at 1300 cm-1 to the C-O and C-C groups of main chain, at 1243 cm-1 a symmetric elongation of C-O-C and at 1168 cm-1 a symmetrical elongation of C-O-C groups.

Figure 4
(a) FT-IR spectra of PCL unexposed and exposed to UV-B radiation and (b) zoom of Figure 5 (a) illustrating absorption wavenumber of carbonyl group

After exposure, the relative peak of carbonyl group (C=O), visualized at 1725 cm-1 broadened what may have been caused by formation of new radicals (C=O) localized in different regions in PCL macromolecules, for instance in terminal groups, this change is suggested as degradation evidence due exposure to UV-B radiation.

Optical microscopy images are presented in Figure 5, it is observed that before exposure PCL had a dense and non-porous surface, Figure 5 (Unexposed). After exposure, Figure 5 for 1 week, presence of micro cracks on PCL surface is verifiable and they increase with exposure. It can be clearly seen in the micrographs (Figure 5 for 2 weeks exposure) presence of crystals inside and near of the cracks 3232 Grigull VH, Mazur LP, Garcia MCF, Schneider ALS, Pezzin APT. Estudo da degradação de blendas de poli(hidroxibutirato-co-hidroxivalerato)/poli(l-ácido lático) em diferentes condições ambientais. Engevista. 2015;17(4):444-462..

Figure 5
Optical microscopy images of PCL unexposed and exposed to UV-B radiation

Regarding the cracks and roughness, the researcher groups Grigull et al., 2015 3232 Grigull VH, Mazur LP, Garcia MCF, Schneider ALS, Pezzin APT. Estudo da degradação de blendas de poli(hidroxibutirato-co-hidroxivalerato)/poli(l-ácido lático) em diferentes condições ambientais. Engevista. 2015;17(4):444-462. and Narkis et al., 1985 3333 Narkis M, Sibony-Chaouat S, Siegmann A, Shkolnikt S, Bell JP. Irradiation effects on polycaprolactone. Polymer. 1985;26(1):50-54., agree that these, probably, can be originated from chemi-crystallization as well as from degradation mechanism Norrish II. It is plausible assuming the observed decreasing in mechanical properties may be accelerated by these processes.

Figure 6 shows SEM images for PCL specimens upon UV-B radiation. Unexposed PCL presents ductile fracture with evidences of plastic deformation. After exposure the fracture surface changes and a fibrous morphology is observed. This behavior has been reported for PCL by Tsuji et al. 2006 1919 Tsuji H, Echizen Y, Nishimura Y. Photodegradation of biodegradable polyesters: A comprehensive study on poly(l-lactide) and poly(ɛ-caprolactone). Polymer Degradation and Stability. 2006;91(5):1128-1137., Castilla-Cortazár et al. 2012 3434 Castilla-Cortázar I, Más-Estellés J, Meseguer-Dueñas JM, Escobar Ivirico JL, Marí B, Vidaurre A. Hydrolytic and enzymatic degradation of a poly(e-caprolactone) network. Polymer Degradation and Stability. 2012;97(8):1241-1248 and França et al. 2016 1717 França DC, Bezerra EB, Morais DDS, Araújo EM, Wellen RMR. Hydrolytic and Thermal Degradation of PCL and PCL/Bentonite Compounds. Materials Research. 2016;19(3):618-627. who related this morphological change due to degradation mechanisms called bulk erosion that is when the degradation occurs throughout the whole material, for this case, both the surface and the bulk of the material degrade. These authors observed initially surface erosion followed by the fibrous morphology, being both linked to PCL degradation, similarly to what was verified in the present work in Figure 6.

Figure 6
SEM micrographs of PCL fracture surface exposed to UV-B radiation. Exposure times up to 9 weeks

5. Conclusions

Photodegradation of PCL was analyzed by exposing injected specimens to UV-B radiation up to 9 weeks. From the gathered results was possible assuming that PCL is strongly affected by radiation, its mechanical properties such as elastic modulus and elongation at break changed considerably. FTIR spectra presented alterations related to the carbonyl groups; formation of micro cracks could be observed by optical microscopy. The degree of crystallinity increased for longer exposure time, as probable consequence of chemi-crystallization. In SEM images erosion and fibrous morphologies were verified what can be linked to loses in mechanical properties. Summing up 9 weeks of exposure are enough to considerably damage PCL products.

6. Acknowledgments

The authors are grateful to CNPq and Capes (Brasilia/DF, Brazil) for the financial support and the Fraunhofer Institute for Manufacturing Technology and Advanced Materials-IFAM in Bremen for experiments with Polarized Optical Microscopy (MO).

7. References

  • 1
    Bastioli C, ed. Handbook of Biodegradable Polymers Shawbury: Rapra Technology; 2005.
  • 2
    Mohanty AK, Misra M, Drzal LT, eds. Natural Fibers, Biopolymers, and Biocomposites Singapore: Taylor & Francis; 2005.
  • 3
    Biron M. The Plastics Industry: Economic Overwiew. In: Biron M. Thermosets and Composites - Material Selection, Applications, Manufacturing and Cost Analysis 2nd ed. Amsterdam: William Andrew; 2014. p. 25-104.
  • 4
    Emblem A. Plastics Properties for Packing Materials In: Emblem A, ed. Packing Technology - Fundamentals, Materials and Processes. Oxford: Woodhead Publishing; 2012. p. 287-309.
  • 5
    Van Hung N, De Schryver P, Tam TT, Garcia-Gonzalez L, Bossier P, Nevejan N. Application of poly-ß-hydroxybutyrate (PHB) in mussel larviculture. Aquaculture 2015;446:318-324.
  • 6
    Li X, Qi C, Han L, Chu C, Bai J, Guo C, et al. Influence of dynamic compressive loading on the in vitro degradation behavior of pure PLA and Mg/PLA composite. Acta Biomaterialia 2017;64:269-278.
  • 7
    Sungkapreecha C, Iqbal N, Gohn AM, Focke WW, Androsch R. Phase behavior of the polymer/drug system PLA/DEET. Polymer 2017;126:116-125.
  • 8
    Laycock B, Nikolic M, Colwell JM, Gauthier E, Halley P, Bottle S, et al. Lifetime prediction of biodegradable polymers. Progress in Polymer Science 2017;71:144-189.
  • 9
    Wachirahuttapong S, Thongpin C, Sombatsompop N. Effect of PCL and Compatibility Contents on the Morphology, Crystallization and Mechanical Properties of PLA/PCL Blends. Energy Procedia 2016;89:198-206.
  • 10
    Hsu ST, Tan H, Yao YL. Effect of excimer laser irradiation on crystallinity and chemical bonding of biodegradable polymer. Polymer Degradation and Stability 2012;97(1):88-97.
  • 11
    Badia JD, Gil-Castell O, Ribes-Greus A. Long-term properties and end-of-life of polymers from renewable resources. Polymer Degradation and Stability 2017;137:35-57.
  • 12
    Wang Y, Pan J, Han X, Sinka C, Ding L. A phenomenological model for the degradation of biodegradable polymers. Biomaterials 2008;29(23):3393-3401.
  • 13
    Abdel-Rehim HA, Yoshii F, Kume T. Modification of polycaprolactone in the presence of polyfunctional monomers by irradiation and its biodegradability. Polymer Degradation and Stability 2004;85(1):689-695.
  • 14
    Zhao Q, Tao J, Yam RCM, Mok ACK, Li RKY, Song C. Biodegradation behavior of polycaprolactone/rice husk ecocomposites in simulated soil medium. Polymer Degradation and Stability 2008;93(8):1571-1576.
  • 15
    De Paoli MA. Degradação e Estabilização de Polímeros 2ª versão on-line. Chemkeys; 2008. Available from: < http://www.chemkeys.com/blog/wp-content/uploads/2008/09/polimeros.pdf>. Access in: 30/1/2018.
    » http://www.chemkeys.com/blog/wp-content/uploads/2008/09/polimeros.pdf
  • 16
    Copinet A, Bertrand C, Govindin S, Coma V, Couturier Y. Effects of ultraviolet light (315 nm), temperature and relative humidity on the degradation of polylactic acid plastic films. Chemosphere 2004;55(5):763-773.
  • 17
    França DC, Bezerra EB, Morais DDS, Araújo EM, Wellen RMR. Hydrolytic and Thermal Degradation of PCL and PCL/Bentonite Compounds. Materials Research 2016;19(3):618-627.
  • 18
    Bhullar SK, Rana D, Lekesiz H, Bedeloglu AC, Ko J, Cho Y, et al. Design and fabrication of auxetic PCL nanofiber membranes for biomedical applications. Materials Science and Engineering: C 2017;81:334-340.
  • 19
    Tsuji H, Echizen Y, Nishimura Y. Photodegradation of biodegradable polyesters: A comprehensive study on poly(l-lactide) and poly(ɛ-caprolactone). Polymer Degradation and Stability 2006;91(5):1128-1137.
  • 20
    Christensen PA, Egerton TA, Franchetti SM, Jin C, White JR. Photodegradation of polycaprolactone/poly(vinyl chloride) blend. Polymer Degradation and Stability 2008;93(1):305-309.
  • 21
    Bei J, He W, Hu X, Wang S. Photodegradation behavior and mechanism of block copoly(caprolactone-ethylene glycol). Polymer Degradation and Stability 2000;67(2):375-380.
  • 22
    Rabello MS, White JR. The role of physical structure and morphology in the photodegradation behaviour of polypropylene. Polymer Degradation Stability 1997;56(1):55-73.
  • 23
    Rabello MS, White JR. Crystallization and melting behaviour of photodegraded polypropylene - II. Re-crystallization of degraded molecules. Polymer 1997;38(26):6379-6387.
  • 24
    Wellen RMR, Canedo EL, Rabello MS, Fechine GJM. Photodegradation and Photostabilization of Poly(3-Hydroxybutyrate). Materials Research 2016;19(4):759-764.
  • 25
    Santonja-Blasco L, Ribes-Greus A, Alamo RG. Comparative thermal, biological and photodegradation kinetics of polylactide and effect on crystallization rates. Polymer Degradation and Stability 2013;98(3):771-784.
  • 26
    Vaughan AS, Stevens GC. On radiation effects in poly(ethylene terephthalate): a comparison with poly(ether ether ketone). Polymer 1995;36(8):1541-1547.
  • 27
    Mandelkern L. Crystallization of Polymers. Volume 1: Equilibrium Concepts 2nd ed. Cambridge: Cambridge University Press; 2002. p. 249.
  • 28
    Mandelkern L, Alamo RG. Thermodynamic Quantities Governing Melting. In: Mark JE, ed. Physical Properties of Polymers Handbook 2nd ed. New York: Springer; 2007. p. 165-186.
  • 29
    Van Krevelen DW, Te Nijenhuis K. Properties of Polymers 4th ed. Amsterdam: Elsevier; 2009. p. 121.
  • 30
    Elzein T, Nasser-Eddine M, Delaite C, Bistac S, Dumas P. FTIR study of polycaprolactone chain organization at interfaces. Journal of Colloid and Interface Science 2004;273(2):381-387.
  • 31
    Lin-Vien D, Colthup NB, Fateley WG, Grassselli J. The Handbook of Infrared and Raman Characteristic Frequencies of Organic Molecules London: Academic Press; 1991.
  • 32
    Grigull VH, Mazur LP, Garcia MCF, Schneider ALS, Pezzin APT. Estudo da degradação de blendas de poli(hidroxibutirato-co-hidroxivalerato)/poli(l-ácido lático) em diferentes condições ambientais. Engevista 2015;17(4):444-462.
  • 33
    Narkis M, Sibony-Chaouat S, Siegmann A, Shkolnikt S, Bell JP. Irradiation effects on polycaprolactone. Polymer 1985;26(1):50-54.
  • 34
    Castilla-Cortázar I, Más-Estellés J, Meseguer-Dueñas JM, Escobar Ivirico JL, Marí B, Vidaurre A. Hydrolytic and enzymatic degradation of a poly(e-caprolactone) network. Polymer Degradation and Stability 2012;97(8):1241-1248

Publication Dates

  • Publication in this collection
    16 July 2018
  • Date of issue
    2018

History

  • Received
    20 Sept 2017
  • Reviewed
    26 Feb 2018
  • Accepted
    05 June 2018
ABM, ABC, ABPol UFSCar - Dep. de Engenharia de Materiais, Rod. Washington Luiz, km 235, 13565-905 - São Carlos - SP- Brasil. Tel (55 16) 3351-9487 - São Carlos - SP - Brazil
E-mail: pessan@ufscar.br