Long-term mechanical assisted circulation devices

Heart failure syndrome is the final presentation of a series of cardiac diseases. According to the Department of Informatics of the Brazilian National Health System (DATASUS), cardiovascular diseases are the third largest cause of hospitalizations in Brazil and heart failure is the main cause of cardiovascular hospital admissions in this country.

Despite all the advances in treatments for heart failure, a significant proportion of such patients evolve to states of refractoriness to clinical treatment. In these situations, it becomes necessary to use advanced procedures such as heart transplantation and long-term mechanical assisted circulation devices.

Heart transplantation is still the gold-standard treatment for refractory heart failure and the mean survival after this procedure is 11 years.11 Khush KK, Cherikh WS, Chambers DC, et al. The International Thoracic Organ Transplant Registry of the International Society for Heart and Lung Transplantation: Thirty-sixth adult heart transplantation report - 2019; focus theme: Donor and recipient size match. J Heart Lung Transplant. 2019;38(10):1056-66. PMID: 31548031; https://doi.org/10.1016/j.healun.2019.08.004. Erratum in: J Heart Lung Transplant. 2020;39(1):91.
https://doi.org/10.1016/j.healun.2019.08...
However, a large proportion of such patients cannot benefit from this procedure either because of contraindications or because of lack of availability of organs.

In the light of this scenario, there has been great pressure to develop therapies that provide an alternative to transplantation. This has culminated in the introduction of long-term mechanical assisted circulation devices.22 Kirklin JK, Pagani FD, Kormos RL, et al. Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. J Heart Lung Transplant. 2017t;36(10):1080-6. PMID: 28942782; https://doi.org/10.1016/j.healun.2017.07.005.
https://doi.org/10.1016/j.healun.2017.07...

The beginnings of the development of mechanical assisted circulation devices date back to 1950, when an extracorporeal circulation machine was first used. In 1964, the National Heart and Lung Institute of the United States created an artificial heart program. Twenty years later, in the 1980s, tests on the HeartMate XVE implant began.

HeartMate XVE was the first generation of long-term mechanical assisted circulation devices. It propelled the blood flow by means of a pulsatile pump that attempted to mimic the flow in the left ventricle. This device was tested in the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) trial33 Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345(20):1435-43. PMID: 11794191; https://doi.org/10.1056/NEJMoa012175.
https://doi.org/10.1056/NEJMoa012175...
and was shown to provide a reduction of 48% in the risk of death over a one-year period. However, use of this device presented a high rate of complications such as thromboembolic events and hemolysis.

In 2007, a study comparing HeartMate XVE and HeartMate II, a second-generation device, was published. This new device had a different mechanism, consisting of continuous axial flow. Its technology brought in the advantage of being a smaller device that could be used by individuals of lesser build, with the expectation that it would be possible to use it for a long period, given that it only had a single moving part, its rotor.44 Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361(23):2241-51. PMID: 19920051; https://doi.org/10.1056/NEJMoa0909938. Erratum in: N Engl J Med. 2018;379(7):697.
https://doi.org/10.1056/NEJMoa0909938...

Subsequently, axial flow devices dominated in the field of long-term mechanical assisted circulation, for a long period. Centrifugal flow devices then emerged, which brought in the advantages of miniaturization, intrapericardial placement and a bearing-free rotor, achieved through the technologies of electromagnetic or hydrodynamic levitation. These devices reduced hemolysis and adverse events relating to hemocompatibility.55 Mehra MR, Naka Y, Uriel N, et al. A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure. N Engl J Med. 2017;376(5):440-50. PMID: 27959709; https://doi.org/10.1056/NEJMoa1610426.
https://doi.org/10.1056/NEJMoa1610426...
77 Rogers JG, Pagani FD, Tatooles AJ, et al. Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. N Engl J Med. 2017;376(5):451-60. PMID: 28146651; https://doi.org/10.1056/NEJMoa1602954.
https://doi.org/10.1056/NEJMoa1602954...

The latest report from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) showed that 77.7% of the long-term devices used in 2019 made use of magnetic levitation, thus showing the growth in this technology over recent years.88 Molina EJ, Shah P, Kiernan MS, et al. The Society of Thoracic Surgeons Intermacs 2020 Annual Report. Ann Thorac Surg. 2021;111(3):778-92. PMID: 33465365; https://doi.org/10.1016/j.athoracsur.2020.12.038.
https://doi.org/10.1016/j.athoracsur.202...

Implantation of long-term mechanical assisted circulation devices can be indicated through the following strategies: 1 – As a bridge to candidacy: in situations of clinical conditions that prohibit heart transplantation but which if modifiable would allow the patient to become a candidate for transplantation (for example: pulmonary hypertension and neoplasias that are potentially curable); 2 – As a bridge to transplantation: in situations in which the device might provide hemodynamic support and clinical stability until the heart transplantation is performed, within a context of progressively increasing severity of the patient's condition and unavailability of an organ for transplantation within the short term; 3 – As destination therapy: in situations in which the device might provide hemodynamic support and clinical stability for a patient with refractory heart failure who presents contraindications for heart transplantation, thus enabling greater survival and better quality of life, in comparison with clinical treatment using medications.99 Ayub-Ferreira SM, Souza JD Neto, Almeida DR, et al. Diretriz de Assistência Circulatória Mecânica da Sociedade Brasileira de Cardiologia. Arq Bras Cardiol. 2016;107(2 Suppl 2):1-33. PMID: 27627754; https://doi.org/10.5935/abc.20160128.
https://doi.org/10.5935/abc.20160128...

In Brazil, experience with these devices remains sparse,1010 Rangel BSS, Biselli B, Quintanilha NR, et al. Early reduction of pulmonary arterial hypertension in patients using a long-term mechanical ventricular assist device: a cross-sectional study. Sao Paulo Med J. 2022;140(3):505-8. https://doi.org/10.1590/1516-3180.2021.0944.R2.18032022.
https://doi.org/10.1590/1516-3180.2021.0...
given their high cost and the potential growth in the number of heart transplantations that has occurred over recent decades.1111 Marcondes-Braga FG, Bonatto MG, Andrade CRA, Bacal F. Implementationof Heart Transplantation Program to Advanced Heart Failure Patients in Brazil. Curr Heart Fail Rep. 2019;16(1):7-11. PMID: 30712146; https://doi.org/10.1007/s11897-019-0418-z.
https://doi.org/10.1007/s11897-019-0418-...
These factors have left Brazil well behind with regard current treatments for advanced heart failure.

Within the worldwide scenario, what we see is that improvements in the technology of long-term mechanical assisted circulation devices and in the expertise of medical teams have consequentially increased the survival of such patients. This has given rise to changes in the range of options for treating refractory heart failure. Long-term mechanical assisted circulation devices are increasing gaining space: not only at the transplantation point but also, especially, as destination therapy, which accounted for more than 70% of the indications in 2019.88 Molina EJ, Shah P, Kiernan MS, et al. The Society of Thoracic Surgeons Intermacs 2020 Annual Report. Ann Thorac Surg. 2021;111(3):778-92. PMID: 33465365; https://doi.org/10.1016/j.athoracsur.2020.12.038.
https://doi.org/10.1016/j.athoracsur.202...

  • Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR

REFERENCES

  • 1
    Khush KK, Cherikh WS, Chambers DC, et al. The International Thoracic Organ Transplant Registry of the International Society for Heart and Lung Transplantation: Thirty-sixth adult heart transplantation report - 2019; focus theme: Donor and recipient size match. J Heart Lung Transplant. 2019;38(10):1056-66. PMID: 31548031; https://doi.org/10.1016/j.healun.2019.08.004 Erratum in: J Heart Lung Transplant. 2020;39(1):91.
    » https://doi.org/10.1016/j.healun.2019.08.004
  • 2
    Kirklin JK, Pagani FD, Kormos RL, et al. Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. J Heart Lung Transplant. 2017t;36(10):1080-6. PMID: 28942782; https://doi.org/10.1016/j.healun.2017.07.005
    » https://doi.org/10.1016/j.healun.2017.07.005
  • 3
    Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345(20):1435-43. PMID: 11794191; https://doi.org/10.1056/NEJMoa012175
    » https://doi.org/10.1056/NEJMoa012175
  • 4
    Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361(23):2241-51. PMID: 19920051; https://doi.org/10.1056/NEJMoa0909938 Erratum in: N Engl J Med. 2018;379(7):697.
    » https://doi.org/10.1056/NEJMoa0909938
  • 5
    Mehra MR, Naka Y, Uriel N, et al. A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure. N Engl J Med. 2017;376(5):440-50. PMID: 27959709; https://doi.org/10.1056/NEJMoa1610426
    » https://doi.org/10.1056/NEJMoa1610426
  • 6
    Mehra MR, Goldstein DJ, Uriel N, et al. Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. N Engl J Med. 2018;378(15):1386-95. PMID: 29526139; https://doi.org/10.1056/NEJMoa1800866
    » https://doi.org/10.1056/NEJMoa1800866
  • 7
    Rogers JG, Pagani FD, Tatooles AJ, et al. Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. N Engl J Med. 2017;376(5):451-60. PMID: 28146651; https://doi.org/10.1056/NEJMoa1602954
    » https://doi.org/10.1056/NEJMoa1602954
  • 8
    Molina EJ, Shah P, Kiernan MS, et al. The Society of Thoracic Surgeons Intermacs 2020 Annual Report. Ann Thorac Surg. 2021;111(3):778-92. PMID: 33465365; https://doi.org/10.1016/j.athoracsur.2020.12.038
    » https://doi.org/10.1016/j.athoracsur.2020.12.038
  • 9
    Ayub-Ferreira SM, Souza JD Neto, Almeida DR, et al. Diretriz de Assistência Circulatória Mecânica da Sociedade Brasileira de Cardiologia. Arq Bras Cardiol. 2016;107(2 Suppl 2):1-33. PMID: 27627754; https://doi.org/10.5935/abc.20160128
    » https://doi.org/10.5935/abc.20160128
  • 10
    Rangel BSS, Biselli B, Quintanilha NR, et al. Early reduction of pulmonary arterial hypertension in patients using a long-term mechanical ventricular assist device: a cross-sectional study. Sao Paulo Med J. 2022;140(3):505-8. https://doi.org/10.1590/1516-3180.2021.0944.R2.18032022
    » https://doi.org/10.1590/1516-3180.2021.0944.R2.18032022
  • 11
    Marcondes-Braga FG, Bonatto MG, Andrade CRA, Bacal F. Implementationof Heart Transplantation Program to Advanced Heart Failure Patients in Brazil. Curr Heart Fail Rep. 2019;16(1):7-11. PMID: 30712146; https://doi.org/10.1007/s11897-019-0418-z
    » https://doi.org/10.1007/s11897-019-0418-z

Publication Dates

  • Publication in this collection
    16 May 2022
  • Date of issue
    May-Jun 2022
Associação Paulista de Medicina - APM APM / Publicações Científicas, Av. Brigadeiro Luís Antonio, 278 - 7º and., 01318-901 São Paulo SP - Brazil, Tel.: +55 11 3188-4310 / 3188-4311, Fax: +55 11 3188-4255 - São Paulo - SP - Brazil
E-mail: revistas@apm.org.br