Corrosion of galvanic pairs of dental alloys copper base with silver amalgams in artificial saliva

Corrosión de pares galvánicos de aleaciones dentales base cobre con amalgamas de plata en saliva artificial

ABSTRACT

Galvanic corrosion is a metal dissolution process that occurs when two metals of different electrochemical potential are immersed in an electrolyte causing electrical currents between the metals through the conducting medium. To restore lost or damaged teeth, different alloys are used, leaving the mouth exposed to electrical currents that circulate through saliva and dental fluids. In the present work, the potentials and densities of corrosion currents of galvanic pairs of silver amalgams and copper base dental alloys were determined simultaneously using potenciodynamic methods, finding that the most resistant to corrosion are the pairs formed by silver amalgams of high copper and Cu -Zn alloys, and that the corrosion products released in greater quantity in the electrolytic medium are formed by Hg, Cu, Zn and Ni ions.

Keywords
Corrosion; dental alloy; polarization curve; artificial saliva; galvanic pair

RESUMEN

La corrosión galvánica es un proceso de disolución metálica que se produce cuando dos metales de distinto potencial electroquímico se sumergen en un electrolito originando corrientes eléctricas entre los metales a través del medio conductor. Para restaurar las piezas dentales perdidas o deterioradas se usan diferentes aleaciones quedando la boca expuesta a corrientes eléctricas que circulan a través de la saliva y los fluidos dentarios. En el presente trabajo se determinaron simultáneamente, los potenciales y densidades de corrientes de corrosión de pares galvánicos de amalgamas de plata y aleaciones dentales base cobre usando métodos potenciodinámicos, encontrando que los más resistentes a la corrosión son los pares formados por amalgamas de plata de alto cobre y aleaciones Cu – Zn, y que los productos de corrosión liberados en mayor cantidad en el medio electrolítico están formados por iones Hg, Cu, Zn y Ni.

Palabras clave
Corrosión; aleación dental; curva de polarización; saliva artificial; par galvánico

1. INTRODUCTION

The dental alloys have application in the restoration and correction of lost or misaligned dental pieces to preserve the correct masticatory function and the aesthetic aspect. The designs of these prostheses can take various forms and all branches of dentistry such as restorative, orthodontic, endodontic, implantology, periodontics and geriatrics apply these models [11 MUELLER, H. J., “Tarnish and Corrosion of Dental Alloys”, In Metal Handbook, v. 13, Ohio, Ed. ASM International Metal Park, pp. 1336 -1366, 1992.,22 PHILLIPS, R. W., La Ciencia de los Materiales Dentales, 9° Edición, Cap. 16, Editorial Interamericana, México, 1988.].

Alloys are used for direct fillings (amalgams), crowns, bridges, inlays, partial or total prostheses, fixed or mobile, implanted structures, or in the form of wires to correct defects in mastication using orthodontic appliances. These alloys are usually as cast, but in certain applications welding or bonding with porcelain or special polymers is required.

To fulfill these functions the alloys must meet a variety of biocompatibility requirements, suitable physical properties, wear resistance or corrosion resistance and acceptable and stable appearance. The most traditional are noble alloys containing not less than 75% gold and platinum group metals. The techniques of casting, cast and finished are simple and do not suffer deterioration of their properties over time or lose their aesthetic appearance. In contrast, they have the disadvantage of having high density, under elastic modulus and are too expensive [33 Guide to Dental Materials and Device, American Dental Association, 7 th Ed., Chicago, 1974.].

For this reason, alloys of non-precious metals have been developed to replace high gold alloys, which have been used since the 1940s in developed countries. Among these we have the ones of Co -Cr, Ni -Cr and lately those of base titanium. In developing countries such as ours copper base alloys are used: Cu -Al, Cu -Zn and Cu -Ni and amalgams of silver of low and high copper by its reduced cost, as has been mentioned in foreign publications [44 NAKAYAMA, M., MOSER, J. B. AND GREENER, E.H. “Corrosion and Tarnish of Aluminum Bronze”, Dent. Mater. J., v.3, pp.133, 1984.] and manifested in presentations made by various researchers at the meetings of the Argentine Branch of the International Association for Dental Research [55 Proc. XXIII Reunión Anual de la División Argentina de la International Association for Dental Research (I.A.D.R.), Buenos Aires, 1990.

6 Proc. XXIV Reunión Anual de la División Argentina de la International Association for Dental Research (I.A.D.R.), Villa Giordano (Córdoba), 1991.
-77 Proc. XXV Reunión Anual de la División Argentina de la International Association for Dental Research (I.A.D.R.), Paraná (Entre Ríos), 1992.].

Two or more dissimilar metals in the mouth form batteries that generate galvanic currents, due to electrolytic contact through the saliva or the root fluids; these pairs interact by direct, indirect or intermittent contact [11 MUELLER, H. J., “Tarnish and Corrosion of Dental Alloys”, In Metal Handbook, v. 13, Ohio, Ed. ASM International Metal Park, pp. 1336 -1366, 1992.]. Research has been carried out on galvanic pairs of alloys of Au, Co -Cr, Ni -Cr, titanium and stainless steel with amalgams [88 HALLAND, R.I., “Galvanic currents between gold and amalgam”, Scand. J Dent Res. v.88, pp. 269-272, 1980.

9 RAVNHOL, G., “Corrosion Current and PH rise around titanium coupled to dental alloys”, Scand. J. Res. v.96, pp. 466-472, 1988.

10 RAVNHOLT, G., JENSEN, J., “Corrosion investigation of two materials for implant supraconstructions coupled to a titanium implant”, Dent. Res. v.99, pp. 181-186, 1991.

11 GRIFFIN, CH., BUCHANAN,R.A., LEMOUS, J.E., “In vitro electrochemical corrosion study of coupled surgical implant materials”, J. of Biomedical Mat. Res. v.17, pp. 489 – 500, 1996.

12 CISZEWSKI, A., BARANIAK, M., URBANEK-BRYCHCZYNSKA, M., “Corrosion by Galvanic Coupling Between Amalgam and Different Chromium-Based Alloys”, Dental Materials, v. 23, pp. 1256 – 1261, Dec. 2007.
-1313 CAPELO, S., PROENCA, L., FERNANDEZ, J., et al., “Galvanic Corrosion of Two Non Noble Dental Alloys”, Int. J. Electrochem. Sci., v. 9, pp. 593 – 609, Sep. 2014.]. In this work we will study the susceptibility to corrosion of galvanic pairs of copper base alloys (Cu -Al, Cu -Zn, and Cu -Ni) with silver amalgams using potenciodynamic methods and later determine the corrosion products by EDAX and SEM.

2. MATERIALS AND METHODS

2.1 Materials

Three copper base dental alloys and two silver amalgams whose chemical composition are shown in table 1 have been used.

Table 1
Chemical composition of amalgams and dental alloys base copper by weight %.

2.2 Preparation of test pieces

  • The copper base samples were prepared by the lost wax method with an oxygen -butane -propane flame and centrifugation processes.

  • The amalgams were crushed and condensed according to the manufacturer's instructions [1414 COIMPA -Sociedade Industrial de Metais Preciosos da Amazonia Ltda. 11. Instrucciones para uso de amalgamas, Brasil.]. In both cases the specimens were cylinders 0.5 cm high and 0.8 cm in diameter.

2.3 Electrochemical methods

To predict the corrosion of galvanic pairs in electrolytic solutions, measurements of potential, polarization and current must be made [1515 BABOIAN, R., “Electrochemical techniques for predicting galvanic corrosion”. In: BOBOIAN, R, FRANCE, W.D J.R, ROEW, L.C., et al., Galvanic and Pitting – field and Laboratory Studies. ASTM stp 556. Philadelphia: American Society for Testing and Materials, pp 6-9, 1976.].

  • Potential measurements -The electrode potential of each alloy was measured with a saturated calomel electrode in a three-electrode cell and a Princeton Applied Research Potenciostat Model 173. Prior to the measurement, the specimen was introduced to the solution and at the same time air was circulated at a rate of 80 bubbles per minute with a fish tank aerator. Before measuring the corrosion potential, it was waited 30 minutes for the potential to stabilize always under the action of the air stream. Potentials were measured five times with different specimens.

  • Polarization curves -The potentiodynamic polarization curves were plotted in triplicate using the same cell and the same potentiostat as the one used to measure the electrode potential. The reference electrode was saturated calomel and the platinum counter electrode. The scanning speed was 12 mV / min and the curves were recorded with an XT Princeton Applied Reserch Model REO 151 plotter. Before plotting the curves the corrosion potential was measured in the same manner as in the previous section. The global curves (anodic and cathodic) of each alloy were drawn with different specimens. Once the tests were finished, the specimens were analyzed with a scanning electron microscope to determine the corrosion products by EDAX.

  • Potential corrosion of galvanic pairs -Dental alloys are corroded in the oral environment by the action of saliva and bone fluids so that when electrically coupled both are polarized and corrode at a new speed. When the metals A and B of equal areas are coupled, the mixed potential and the current density (Ecupla and Icupla) of the galvanic cupla are at the intersection of the anodic curves of the less noble metal (A) and cathodic of the metal plus noble (B) [1616 JONES DENNY A. Principles and Prevention of Corrosion. 2 º Ed. Prentice Hall, Upper Saddle Rivers, N.J., pp. 177, 1996.].

  • Electrolyte -The electrolyte used in electrochemical tests is an experimental saliva that reproduces the electrochemical behavior of natural saliva [1717 DUFFO,G.S., QUEZADA, E., “Development of an Artificial Saliva Solution for Studying the Corrosion Behavior of Dental Alloys”, Corrosion, v. 60, pp. 594–602, Jun. 2004.], whose formula is shown in Table 2. The electrolyte was prepared with deionized water of 18.2 MΩ-cm electrical resistivity and with reagents of analytical grade. The pH of the solution was 6.5; to prevent this value from being modified, KHCO3 must be added shortly before starting the tests.

    Table 2
    Chemical composition of experimental saliva [1717 DUFFO,G.S., QUEZADA, E., “Development of an Artificial Saliva Solution for Studying the Corrosion Behavior of Dental Alloys”, Corrosion, v. 60, pp. 594–602, Jun. 2004.].

RESULTS AND DISCUSSION

3.1 Electrochemical series

Table 3 shows the average open circuit corrosion potentials of the studied alloys according to their resistance to corrosion. The average standard deviation calculated according to G standard: 16-95 ASTM [1818 ASTM Standars: G.16-95. “Standars guide for applying statistics to analysis of corrosion dat”. In, Anual Booke of ASTM Standards, v. 03, pp.02, 1999.] is also shown. Copper base alloys manufactured to substitute gold for their yellow color have high potential for corrosion due to the large amount of copper they contain. In contrast, the Standalloy F amalgam has a low corrosion potential due to the small amount of copper it contains compared to the other alloys considered in this work.

Table 3
Corrosion Potentials and Average Standard Deviations.

3.2 Polarization curves

Dental amalgams are galvanically corroded in the mouth due to the different phases that have: Ag-Hg, Ag-Sn and Sn-Hg, each of which has a different electrochemical potential due to its diverse chemical composition [1919 FATHI, M., MORTAZARVI,V., “A review on Dental Amalgam Corrosion and Its Consecuences”, Journal of Research in Medical Science, v. 9, n. 1, pp. 42-51, 2004.,2020 ACCIARI, H.A., GUASTALDI, A.C., BRETTT, C.M.A., Corrosion of dental amalgam: electrochemical study of Ag-Hg, Ag-Sn and Sn-Hg phases”, Electrochemica Acta, v.42, n. 1, pp.3887-3893, Jan. 2001.]

Figure 1 shows the overall polarization curves of the alloys under study. The cathodic curves of these alloys are similar; for small over cathodic potential the current density increases rapidly observing a linear relationship between the potential envelope and the logarithm of the current. In all cases the cathodic region corresponds to the evolution of hydrogen [2121 GONZALES FERNANDEZ, G.A., Control de la corrosión: estudio y medida por técnicas electroquímicas, 1a Edición, Consej Superior de Investigaciones Científicas. Centro Nacional de Investigaciones Metalúrgicas, pp. 97, Madrid ,1989.].

Figure 1
Polarization curves of silver amalgams and copper base alloys.

The low copper amalgam (Standalloy F) has a passive zone that extends from -370 mVsce to -100 mVsce and its breaking potential is -90 mVsce, from this value the current density increases rapidly. The amalgam of high copper (Duralloy S), not represented in all its extension, have a current density of 2.20 μA/ cm2 at the height of the rupture potentials of aurocast and pentacast. The current density of the Standalloy passive zone is 0.30 μA / cm2 obtained by averaging the current densities of its passive zone.

The most corrosive phase of the low copper amalgam is the γ2 or Sn-Hg phase, due to the formation of tin oxychloride from the tin of the γ2 phase and also the release of mercury [1919 FATHI, M., MORTAZARVI,V., “A review on Dental Amalgam Corrosion and Its Consecuences”, Journal of Research in Medical Science, v. 9, n. 1, pp. 42-51, 2004.]. The high copper quality amalgams do not have phase γ2 and the most corrosion resistant phase of these alloys is the Ag-Hg phase [2222 BRETT, C. M. A., TRANDAFIR, F., “The corrosion of dental amalgam in artificial salivas: an electrochemical impedance study”, Journal of Electroanalytical Chemistry, v. 552, n. 1, pp. 347-354, Feb. 2004.].

The Cu-Al alloy presents a passive zone that extends from -190 mVsce to 180 mVsce with an average current density in this area of 2μA / cm2. Its breaking potential is 200 mVsce, from which dissolution of the interdendritic structure of the alloy known as phase k occurs, formed by segregation of Fe and Ni due to its insolubility in the α phase [2323 BREZINA, P., “Heat treatment of complex aluminium bronzes”, International Metals Reviews, v.21, n.1, pp. 77-120, Jan. 1982.]. The Cu-Ni alloy has a passive zone extending from -160 mVsce to 200 mVsce and a passivation current density of 3 μA / cm2. The breaking potential is 210 mVsce, from which the dissolution of the material takes place. The Cu-Zn alloy has a small passive zone that extends from -180 mVsce up to 20 mVsce and a passive current density of 1.50 μA / cm2. The reduction of this zone compared to the previous alloys is due to its high Zn content[11 MUELLER, H. J., “Tarnish and Corrosion of Dental Alloys”, In Metal Handbook, v. 13, Ohio, Ed. ASM International Metal Park, pp. 1336 -1366, 1992.]. From the rupture potentials the current densities of the copper base alloys rapidly increase to small over potentials as shown in figure 1, due to the selective dissolution of the material known as dealloyed.

Figure 2
Intersection of anodic curve of Standalloy and cathodic of Duralloy with the anodic and cathodic curves of copper base dental alloys.

3.3 Potentials and densities of corrosion current of galvanic pairs

The potential and corrosion current densities of the galvanic pairs under study are determined from the intersection of the cathodic curves of the silver amalgams and the anodic curves of the copper base alloys, as shown in figure 2. The results are presented in table 4.

Table 4
Potentials and corrosion current densities of galvanic pairs of copper base dental alloys with silver amalgam.

In Table 4 we observe that the range of the corrosion potentials of the galvanic pairs of the alloys under study with Standalloy is between -299 mVsce and -247 mVsce and the current densities between 0.244 μA / cm2 and 0.142 μA / cm2. For Duralloy-formed pairs the corrosion potentials are between -255 mVsce and -232 mVsce and the current densities between 0.055 μA / cm2 and 0.004 μA / cm2.

3.4 Corrosion products of galvanic pairs

At the end of the tests the corrosion products were observed with a scanning electron microscope (Phillips 500) and by making a general sweep of the surface of the specimens by EDAX the corrosion products whose spectra are shown in figures 3 to 7 were qualitatively determined.

Figure 3
SEM micrograph and EDAX spectra of corrosion products on Standalloy (× 1440).
Figure 4
SEM micrograph and EDAX spectra of corrosion products on Duralloy (× 1280).
Figure 5
SEM micrograph and EDAX spectra of corrosion products on Pentacast (× 1440).
Figure 6
SEM micrograph and EDAX spectra of corrosion products on Orodent (× 1200).
Figure 7
SEM micrograph and EDAX spectra of corrosion products on Aurocast (× 1120).

Figures 3 and 4 show the SEM micrographs of the corrosion products and the EDAX spectra of the silver amalgam of low and high copper with high peaks of Hg, Sn, Ag, Cl and Cu and small peaks of P, Si and Ca. in agreement with the results of other researchers [2424 SARKAR, N.K., MARSHALL, G. W., MOSER, J.B., et al., “In vivo and In vitro Corrosion Products of Dental Amalgam”, J Dent Res., v. 54, n. 5, pp. 1031-1038, Sep.-Oct. 1975.,2525 FINKELSTEIN, G. F., GREENER, E. H., “In vitro polarization of dental in human saliva”, Journal of Oral Rehabilitation, v.04, n.4, pp.347-354, Oct. 1977.]. Since this technique does not register oxygen or hydrogen, it is assumed that oxides, hydroxides, phosphates and chlorides are formed from these elements, such as those identified by Fathi and Mortazavi in dental patients [1919 FATHI, M., MORTAZARVI,V., “A review on Dental Amalgam Corrosion and Its Consecuences”, Journal of Research in Medical Science, v. 9, n. 1, pp. 42-51, 2004.].

Figures 5 to 7 show the SEM micrographs of the corrosion products and the EDAX spectra of the Cu base alloys, showing high peaks of Cu and Zn and small peaks of Al, Ni and Fe. The analysis of the spectra and the bibliographic references [2626 MUELER, H., “The effects of a human salivary dialysate upon ionic release and electrochemical corrosion of a Copper-Aluminim alloy”, Journal Electrochemical Society, v. 134, n. 3, pp. 575-580, Mar. 1987.,2727 SARKAR, N. K., “SEM and x-ray microanalysis of in vitro corrosion of a copper-zinc alloy”, Journal of Prosthetic Dentistry, v. 45, n. 3, pp. 292-295, Mar. 1981.], indicate that oxides, hydroxides, phosphates and copper chlorides are formed, mainly, and aluminum, iron and nickel, in a minority form.

The ions released in corrosion processes can be stored in the mucosa in the form of staining or pass through the digestive tract to the stomach. Some of them are eliminated abroad and the rest is stored in some organ such as liver, kidneys, lungs or brain [2828 BRUNE, D., GJERDET, N., PAULSEN, G., “Gastrointestinal and in vitro release of copper, cadmium, indium, mercury and zinc from conventional and copper-rich amalgams”, Scand. J. Dent. Res.,v. 91, n. 1,pp. 66 -71, Feb. 1983.].

Cu ions are released when copper amalgams and dental alloys dissolve and are stored in the gingival tissue adjacent to the restored tooth. These ions affect the viability and proliferation of lymphocytes. Over time the concentration of copper increases in the gums, producing inflammation, alteration of cellular immunity and oral homeostasis. In general, these ions contribute to a variety of immunopathological conditions including periodontal diseases and decreased resistance to oral infections [2929 BUMGARDNER, J.D., LUCAS, L.C., ALVERSON, M.W., et al., “Effects of copper-based casting alloys on two lymphocyte cell lines and the secretion of interleukin 2 and Ig”, Dent. Mater.,v. 9, pp. 85 – 90, 1993.].

The major component mercury of amalgams is highly toxic and very permeable through the cell membrane, being able to pass from the gastrointestinal tract to the lungs and brain. It has been found "mercury in the hairs, nails and a high concentration in the pituitary gland (approximately 70 times higher than in the control groups) in people who have amalgams in the mouth" [2929 BUMGARDNER, J.D., LUCAS, L.C., ALVERSON, M.W., et al., “Effects of copper-based casting alloys on two lymphocyte cell lines and the secretion of interleukin 2 and Ig”, Dent. Mater.,v. 9, pp. 85 – 90, 1993.]. Nickel is a potential allergic, and is the most common cause of allergic contact dermatitis, it is present in most jewelry and household utensils. Therefore, it can be considered a danger to public health increasing with the use of dental restorations. Ni ions produce nonspecific allergies and inflammations around restorations that can take lichenoid and sometimes erosive reactions, with women being more hypersensitive to this metal because of the jewelry that they use from an early age [3030 BURROWS, D. “Hypersensitivity to mercury, nickel and chromium in relation to dental materials”, International Dental Journal, v. 36,n. 1, pp. 30-34, Mar. 1986.,3131 BLANCO-DALMA, L., CARRASQUILLO-ALBERT, H., SILVA PARRA, J. “A study of nickel allergy”, J. Prosth Dent, v. 52, n. 1, pp. 116-119, Jul. 1984.].

4. CONCLUSIONS

From the results obtained in the present work it can be established that:

  1. Galvanic pairs of copper base dental alloys with high copper silver amalgams are more resistant to corrosion than pairs formed with low copper silver amalgams. The most resistant pair is PG2,4 (Duralloy / Orodent) and the less resistant the pair PG1,5 (Standalloy / Pentacast).

  2. All dental alloys release ions into the oral environment. Some of these diffuse into the buccal mucosa and the rest pass into the gastrointestinal system. They are then distributed and stored in different parts of the body, such as brain, lungs, liver and kidneys affecting the health of patients, especially when the concentration of corrosion products (Hg, Cu, Ni, etc.) exceeds normal tolerance limits.

ACKNOWLEDGMENT

The Materials Laboratory of the National Commission for Atomic Energy (Constituents) of the Republic Argentina, for allowing us to use their equipment in sections of Corrosion and Electron Microscopy.

BIBLIOGRAPHY

  • 1
    MUELLER, H. J., “Tarnish and Corrosion of Dental Alloys”, In Metal Handbook, v. 13, Ohio, Ed. ASM International Metal Park, pp. 1336 -1366, 1992.
  • 2
    PHILLIPS, R. W., La Ciencia de los Materiales Dentales, 9° Edición, Cap. 16, Editorial Interamericana, México, 1988.
  • 3
    Guide to Dental Materials and Device, American Dental Association, 7 th Ed., Chicago, 1974.
  • 4
    NAKAYAMA, M., MOSER, J. B. AND GREENER, E.H. “Corrosion and Tarnish of Aluminum Bronze”, Dent. Mater. J., v.3, pp.133, 1984.
  • 5
    Proc. XXIII Reunión Anual de la División Argentina de la International Association for Dental Research (I.A.D.R.), Buenos Aires, 1990.
  • 6
    Proc. XXIV Reunión Anual de la División Argentina de la International Association for Dental Research (I.A.D.R.), Villa Giordano (Córdoba), 1991.
  • 7
    Proc. XXV Reunión Anual de la División Argentina de la International Association for Dental Research (I.A.D.R.), Paraná (Entre Ríos), 1992.
  • 8
    HALLAND, R.I., “Galvanic currents between gold and amalgam”, Scand. J Dent Res v.88, pp. 269-272, 1980.
  • 9
    RAVNHOL, G., “Corrosion Current and PH rise around titanium coupled to dental alloys”, Scand. J. Res v.96, pp. 466-472, 1988.
  • 10
    RAVNHOLT, G., JENSEN, J., “Corrosion investigation of two materials for implant supraconstructions coupled to a titanium implant”, Dent. Res v.99, pp. 181-186, 1991.
  • 11
    GRIFFIN, CH., BUCHANAN,R.A., LEMOUS, J.E., “In vitro electrochemical corrosion study of coupled surgical implant materials”, J. of Biomedical Mat. Res v.17, pp. 489 – 500, 1996.
  • 12
    CISZEWSKI, A., BARANIAK, M., URBANEK-BRYCHCZYNSKA, M., “Corrosion by Galvanic Coupling Between Amalgam and Different Chromium-Based Alloys”, Dental Materials, v. 23, pp. 1256 – 1261, Dec. 2007.
  • 13
    CAPELO, S., PROENCA, L., FERNANDEZ, J., et al, “Galvanic Corrosion of Two Non Noble Dental Alloys”, Int. J. Electrochem. Sci, v. 9, pp. 593 – 609, Sep. 2014.
  • 14
    COIMPA -Sociedade Industrial de Metais Preciosos da Amazonia Ltda 11. Instrucciones para uso de amalgamas, Brasil.
  • 15
    BABOIAN, R., “Electrochemical techniques for predicting galvanic corrosion”. In: BOBOIAN, R, FRANCE, W.D J.R, ROEW, L.C., et al, Galvanic and Pitting – field and Laboratory Studies ASTM stp 556. Philadelphia: American Society for Testing and Materials, pp 6-9, 1976.
  • 16
    JONES DENNY A. Principles and Prevention of Corrosion 2 º Ed. Prentice Hall, Upper Saddle Rivers, N.J., pp. 177, 1996.
  • 17
    DUFFO,G.S., QUEZADA, E., “Development of an Artificial Saliva Solution for Studying the Corrosion Behavior of Dental Alloys”, Corrosion, v. 60, pp. 594–602, Jun. 2004.
  • 18
    ASTM Standars: G.16-95. “Standars guide for applying statistics to analysis of corrosion dat”. In, Anual Booke of ASTM Standards, v. 03, pp.02, 1999.
  • 19
    FATHI, M., MORTAZARVI,V., “A review on Dental Amalgam Corrosion and Its Consecuences”, Journal of Research in Medical Science, v. 9, n. 1, pp. 42-51, 2004.
  • 20
    ACCIARI, H.A., GUASTALDI, A.C., BRETTT, C.M.A., Corrosion of dental amalgam: electrochemical study of Ag-Hg, Ag-Sn and Sn-Hg phases”, Electrochemica Acta, v.42, n. 1, pp.3887-3893, Jan. 2001.
  • 21
    GONZALES FERNANDEZ, G.A., Control de la corrosión: estudio y medida por técnicas electroquímicas, 1a Edición, Consej Superior de Investigaciones Científicas. Centro Nacional de Investigaciones Metalúrgicas, pp. 97, Madrid ,1989.
  • 22
    BRETT, C. M. A., TRANDAFIR, F., “The corrosion of dental amalgam in artificial salivas: an electrochemical impedance study”, Journal of Electroanalytical Chemistry, v. 552, n. 1, pp. 347-354, Feb. 2004.
  • 23
    BREZINA, P., “Heat treatment of complex aluminium bronzes”, International Metals Reviews, v.21, n.1, pp. 77-120, Jan. 1982.
  • 24
    SARKAR, N.K., MARSHALL, G. W., MOSER, J.B., et al, “In vivo and In vitro Corrosion Products of Dental Amalgam”, J Dent Res, v. 54, n. 5, pp. 1031-1038, Sep.-Oct. 1975.
  • 25
    FINKELSTEIN, G. F., GREENER, E. H., “In vitro polarization of dental in human saliva”, Journal of Oral Rehabilitation, v.04, n.4, pp.347-354, Oct. 1977.
  • 26
    MUELER, H., “The effects of a human salivary dialysate upon ionic release and electrochemical corrosion of a Copper-Aluminim alloy”, Journal Electrochemical Society, v. 134, n. 3, pp. 575-580, Mar. 1987.
  • 27
    SARKAR, N. K., “SEM and x-ray microanalysis of in vitro corrosion of a copper-zinc alloy”, Journal of Prosthetic Dentistry, v. 45, n. 3, pp. 292-295, Mar. 1981.
  • 28
    BRUNE, D., GJERDET, N., PAULSEN, G., “Gastrointestinal and in vitro release of copper, cadmium, indium, mercury and zinc from conventional and copper-rich amalgams”, Scand. J. Dent. Res,v. 91, n. 1,pp. 66 -71, Feb. 1983.
  • 29
    BUMGARDNER, J.D., LUCAS, L.C., ALVERSON, M.W., et al, “Effects of copper-based casting alloys on two lymphocyte cell lines and the secretion of interleukin 2 and Ig”, Dent. Mater.,v. 9, pp. 85 – 90, 1993.
  • 30
    BURROWS, D. “Hypersensitivity to mercury, nickel and chromium in relation to dental materials”, International Dental Journal, v. 36,n. 1, pp. 30-34, Mar. 1986.
  • 31
    BLANCO-DALMA, L., CARRASQUILLO-ALBERT, H., SILVA PARRA, J. “A study of nickel allergy”, J. Prosth Dent, v. 52, n. 1, pp. 116-119, Jul. 1984.

Publication Dates

  • Publication in this collection
    20 May 2019
  • Date of issue
    2019

History

  • Received
    28 Nov 2017
  • Accepted
    10 Sept 2018
Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro, em cooperação com a Associação Brasileira do Hidrogênio, ABH2 Av. Moniz Aragão, 207, 21941-594, Rio de Janeiro, RJ, Brasil, Tel: +55 (21) 3938-8791 - Rio de Janeiro - RJ - Brazil
E-mail: revmateria@gmail.com