Acessibilidade / Reportar erro

The effect of long-term storage on the microleakage of composite resin restorations: qualitative and quantitative evaluation

Influência do tempo de armazenamento na microinfiltração de restaurações de resina composta: avaliação qualitativa e quantitativa

Abstracts

The aim of this study was to evaluate the influence of storage periods of 24 hours and 3 months on the microleakage of class II cavities. Two methods of assessing microleakage were also compared. Class II cavities were prepared in sound human molars. MO cavities were restored using ABF experimental (Kuraray Medical Inc.) + Z250 composite resin (3M ESPE), and DO cavities were restored using Single Bond (3M ESPE) + Z250. After different storage periods, specimens were thermocycled, immersed in a dye (0.5% methylene blue solution for 4 h) and longitudinally sectioned. Dye penetration was scored according to a 0-4 scale. The extent of microleakage was measured using the ImageLab 2000 program. A statistically significant correlation was verified between both evaluation methods (r = 0.978, p < 0.001). ANOVA revealed a statistically significant difference between the tested adhesive systems regarding microleakage (p < 0.001), although it was not influenced by the different storage periods.

Dentin-bonding agents; Dental leakage; Dental materials


Objetivou-se verificar a influência do tempo de armazenamento (24 horas ou 3 meses) no selamento marginal de restaurações de classe II e, além disso, verificar a correlação entre dois métodos de obtenção dos resultados nos testes de microinfiltração. Cavidades classe II foram confeccionadas em molares humanos íntegros, sendo as cavidades MO restauradas com ABF experimental (Kuraray Medical Inc.) + Z250 (3M ESPE) e as DO, com Single Bond (3M ESPE) + Z250. Após os diferentes tempos de armazenamento, empregou-se uma metodologia para provocar microinfiltração (ciclagem térmica e corante azul de metileno 0,5% por 4 horas) e os corpos-de-prova foram seccionados em 3 fatias. Três avaliadores calibrados atribuíram escores conforme o grau de infiltração, e também foram realizadas medidas morfométricas com ajuda do software ImageLab 2000. A análise de regressão de Pearson mostrou correlação altamente significante entre os valores obtidos pelos dois métodos de avaliação (r = 0,978, p < 0,001). Constatou-se que o adesivo ABF experimental apresentou menor infiltração marginal em relação ao adesivo Single Bond (p < 0,001), sendo que o tempo de armazenamento não influenciou no comportamento dos adesivos.

Adesivos dentinários; Infiltração dentária; Materiais dentários


DENTAL MATERIALS

The effect of long-term storage on the microleakage of composite resin restorations – qualitative and quantitative evaluation† † Study carried out in the Discipline of Experimental Design and Laboratorial Research Technique, Department of Dental Materials, School of Dentistry, University of São Paulo.

Influência do tempo de armazenamento na microinfiltração de restaurações de resina composta – avaliação qualitativa e quantitativa

Fernanda Tranchesi SadekI; Sandra Kiss MouraII; Rafael Yagüe BallesterIII; Antonio MuenchIV; Paulo Eduardo Capel CardosoV

IDoctorate Student

IIMaster Student

IIIAssociate Professor

IVFull Professor

VPhD, Professor – Department of Dental Materials, School of Dentistry, University of São Paulo

ABSTRACT

The aim of this study was to evaluate the influence of storage periods of 24 hours and 3 months on the microleakage of class II cavities. Two methods of assessing microleakage were also compared. Class II cavities were prepared in sound human molars. MO cavities were restored using ABF experimental (Kuraray Medical Inc.) + Z250 composite resin (3M ESPE), and DO cavities were restored using Single Bond (3M ESPE) + Z250. After different storage periods, specimens were thermocycled, immersed in a dye (0.5% methylene blue solution for 4 h) and longitudinally sectioned. Dye penetration was scored according to a 0-4 scale. The extent of microleakage was measured using the ImageLab 2000 program. A statistically significant correlation was verified between both evaluation methods (r = 0.978, p < 0.001). ANOVA revealed a statistically significant difference between the tested adhesive systems regarding microleakage (p < 0.001), although it was not influenced by the different storage periods.

Descriptors: Dentin-bonding agents; Dental leakage; Dental materials.

RESUMO

Objetivou-se verificar a influência do tempo de armazenamento (24 horas ou 3 meses) no selamento marginal de restaurações de classe II e, além disso, verificar a correlação entre dois métodos de obtenção dos resultados nos testes de microinfiltração. Cavidades classe II foram confeccionadas em molares humanos íntegros, sendo as cavidades MO restauradas com ABF experimental (Kuraray Medical Inc.) + Z250 (3M ESPE) e as DO, com Single Bond (3M ESPE) + Z250. Após os diferentes tempos de armazenamento, empregou-se uma metodologia para provocar microinfiltração (ciclagem térmica e corante azul de metileno 0,5% por 4 horas) e os corpos-de-prova foram seccionados em 3 fatias. Três avaliadores calibrados atribuíram escores conforme o grau de infiltração, e também foram realizadas medidas morfométricas com ajuda do software ImageLab 2000. A análise de regressão de Pearson mostrou correlação altamente significante entre os valores obtidos pelos dois métodos de avaliação (r = 0,978, p < 0,001). Constatou-se que o adesivo ABF experimental apresentou menor infiltração marginal em relação ao adesivo Single Bond (p < 0,001), sendo que o tempo de armazenamento não influenciou no comportamento dos adesivos.

Descritores: Adesivos dentinários; Infiltração dentária; Materiais dentários.

INTRODUCTION

The rapid pace at which adhesive systems and aesthetic restorative materials are developed and introduced in the marketplace has contributed to enhance the quality of restorative dentistry over the last few years. Although this fact is uncontestable, adhesive bonding to dental structures is still a great challenge, specially to areas in dentin6,8,12,13,22. Failures in the tooth/restoration interface may result in bacterial penetration or infiltration of saliva components, which may result in marginal discoloration, secondary caries and even pulp injury5,19,20,27.

In an attempt to minimize such problems, manufacturers have introduced new products with different formulations and more effective techniques. Nowadays, the most commonly used adhesive systems try to combine effectiveness with simplicity, so that they can be used both in dentin and enamel3,6,8,13,21,23. Among these, one-bottle and self-etching primers must be emphasized.

One-bottle systems combine priming and bonding components in a single bottle, and must be applied to moist dentinal substrate17,22, previously etched using phosphoric acid3,12,14,24,27. Leaving dentin moist renders the technique sensitive, since it is difficult to clinically measure the ideal level of moisture that must be left following washing of the etching agent17,19. Overdrying may result in the collapse of collagen fibers22,25,27, and prevent adequate monomer penetration. On the other hand, excessive moisture may promote dissolution of bonding monomers and damage the adhesive process12,17,24. These difficulties may result in post-operative sensitivity, which is generally caused by an imperfect sealing of the dentinal tubules after restoration completion1,3,13,27.

Self-etching primer systems were then developed in an effort to minimize technique sensitivity. They were recently introduced in the Brazilian marketplace and are based on the use of an acidic monomer which promotes decalcification of the mineral components and does not require washing and drying steps. The penetration of hydrophilic monomers throughout dental structures occurs simultaneously with tissue demineralization, followed by application of the bonding resin. Clinically, besides combining etching and priming steps, this system eliminates the need for standardization of the moisture that should be left in an specific level before primer application3,25. Moreover, the risk of incomplete impregnation of the demineralized dentin layer with the priming agent is also eliminated, as demineralization occurs at the same depth as the acidic monomers penetrate, since they are combined25. Hence, an enhanced dentinal sealing is theoretically guaranteed, thus reducing the probability of postoperative sensitivity1,3,11-13,27.

Both one-bottle and self-etching primer systems have been constantly studied and due to the great development of new products, laboratory research becomes of fundamental importance, since they try to predict the clinical performance of a new material in a short period of time. However, most studies performed these assays 24 hours after the restoration was finished1,5,6,16-20,22,26, without considering a possible marginal degradation of the tooth/restoration interface in such a hostile moist environment as the oral cavity2,7,9-11,16,21. Undoubtedly, it is also of great importance to evaluate the performance of new adhesive systems following a certain period of time.

Among laboratory tests, we have to emphasize the evaluation of marginal sealing, which is performed using several methods4,7,8,13,19,20,27. The analysis of microleakage by means of dye penetration is one of the most commonly used methods4-8,15,18-20,22,23,26, due to its simplicity and quick accomplishment. Traditionally, microleakage assessment is performed by visual analysis, performed by previously calibrated examiners4-6,13,15. Although this is the most commonly employed method, dye penetration analysis may be subjective4,23 and result in less precise results, even after examiner calibration.

Recently, the morphometric evaluation of microleakage has been used in an attempt to reduce the subjectivity of visual methods, as it is considered as more reliable, although it requires special equipment23,26. In this method, measurements are performed on the linear extension or on the area of microleakage with the aid of an image processor software. Specimens are photographed and, after digitalization, the software delimitates dye penetration using a special tool from the referred system.

Hence the objective of this study is to verify the influence of long-term storage in distilled water at 37°C (24 hours or 3 months) on the microleakage of class II resin-based composite restorations with cervical margins in dentin using 2 adhesive systems, a one-bottle and a self-etching primer system. A possible correlation between visual and morphometric methods of microleakage evaluation was also assessed.

MATERIAL AND METHODS

This study was approved by the Ethics in Research Committee, School of Dentistry, University of São Paulo, according to protocol number 48/02, approved in March, 2002, and report number 23/02.

Twenty sound human molars were extracted for orthodontic reasons and stored in distilled water at 37°C for a maximum post-extraction period of 90 days19. Previously to cavity preparations, tooth apices were sealed using Super Bonder® gel (Loctite, Itapevi, Brazil). After that, root portions were coated with 3 coats of nail polish (Nutra Nail®, Up Cosmetics, Los Angeles, USA). Teeth were then embedded in PVC tubes (Tigre, São Paulo, Brazil) using Epoxide polyester resin (Buhler, Lake Bluff, IL, USA), activated using butanox M 50 catalyst, code BUTA/100 (Redelease®, S.S. White, Rio de Janeiro, Brazil), maintaining the cement/enamel junction at a distance of 2 mm from the embedding resin (Figure 1).


Two class II preparations (MO/DO) were cut in each tooth with the following dimensions: 4 mm of width, 5 mm of height and 1.5 mm of depth towards the pulp. Preparations were made using number 3100 diamond burs (KG Sorensen, Barueri, Brazil) and a high-speed handpiece under constant water cooling. Cavity standardization was obtained by using a special aligning device that allowed controlled movements on the three spatial directions6. Burs were replaced at each five cavity preparations6,23.

After that, cavities were cleaned using pumice paste (S.S. White, Rio de Janeiro, Brazil) in a Robson brush (KG Sorensen, Barueri, Brazil). MO preparations were restored using ABF experimental (Kuraray Medical Inc., Osaka, Japan) and DO were restored using Single Bond (3M ESPE, St. Paul, USA). All materials were applied strictly following the manufacturers’ instructions. Restorations were made using Z250 composite resin shade C3 (3M ESPE, St. Paul, USA) placed in increments of approximately 1 mm, so that each one was light-cured for 20 s using an Optilux 500 light-curing unit (Demetron/Kerr, Danbury, CT, USA), whose readings were maintained in 750 mW/cm2.

After storage in distilled water at 37°C for 24 hours, all restorations were finished using polyester grinding papers (3M ESPE, St. Paul, USA).

For group 1 (n = 10)20, teeth were immediately submitted to thermal cycling in 700 cycles between water baths held at 5° and 55°C, 1 min dwell time and 3 s of interval between each bath15,19. For group 2, teeth were again stored in distilled water at 37°C for a period of 3 months. After that, thermal cycling was carried out as described for group 1.

Upon completion, tooth surfaces were coated with 3 coats of nail polish, except for the restoration and a 1 mm rim of tooth structure. Specimens were immersed in 0.5% methylene blue solution (Fórmula & Ação, São Paulo, Brazil) for 4 hours (neutral pH)19. Teeth were thoroughly washed under tap water and sectioned longitudinally using a diamond disc mounted on a Labcut 1010 machine (Extec Corp., Enfield, USA) under water cooling, so that 3 sections with approximately 1 mm of thickness were obtained for each restoration18,23. Sections were embedded in PVC tubes with 0.5 mm of height using chemically-activated acrylic resin (JET Clássico®, Artigos Odontológicos Clássico, São Paulo, Brazil) in a 1:1 ratio, to protect and facilitate manipulation during microleakage assessments.

Visual analysis was performed by 3 previously calibrated examiners under a stereomicroscope with 25 X magnification (Baucsh & Lomb, Rochester, NY, USA) according to the microleakage scores demonstrated in Figure 215. After scores were attributed, results were analyzed regarding examiner agreement.


The section that presented the highest microleakage score determined the final result, and was also submitted to morphometric analysis. For this study, the ImageLab 200027 image segmentation program was employed to assess dye penetration. This system consisted of a Digital Sony camera (Hyper HAD, Sony Corporation, Tokio, Japan) adapted to a Citoval 2 stereomicroscope (Carl Zeiss Jena, Germany), which was connected to a Pavilion microcomputer (HP, Palo Alto, California, USA) equipped with a digitalizer plate and the processing software ImageLab 2000 (Canborough, Wellandport, Ontario, Canada). After image scanning, linear measurements in mm could be obtained and recorded for each section.

Firstly, to verify if there was a correlation between methods of evaluation, in which parametric and non-parametric data should be obtained, scores were turned into millimeters proportionally to the cavity size. For example: a score 1 attributed to a cavity whose axial wall was 1.8 mm deep was turned into 0.6 mm (one third of 1.8 mm); scores 0 were maintained as 0 mm, despite the cavity size. Results were submitted to Pearson’s regression analysis. Results regarding adhesive systems and storage periods were also submitted to ANOVA and Tukey’s test.

RESULTS

Regarding the two methods of evaluation, Pearson’s regression analysis presented highly significant correlation (r = 0.978, p < 0.001) between visual and morphometric methods (Graph 1), thus emphasizing that both can be reliably used and produce equivalent results.


ANOVA demonstrated no statistically significant difference between the two studied methods (p > 0.05). Regarding adhesive systems, the analysis demonstrated statistically significant differences (p < 0.001), indicating that the ABF experimental presented less microleakage when compared to the Single Bond adhesive system, either after the immediate (24 hours) or the 3-month storage period in distilled water (Table 1).

The storage period did not significantly influence the results of microleakage (p > 0.05), showing that the storage period in distilled water for 3 months had no influence on the performance of the two tested adhesive systems (Table 2).

DISCUSSION

Pearson’s regression analysis demonstrated a highly significant correlation between the tested methods of evaluation. Moreover, it is possible to observe that the reliability interval at the level of 5% varied from 0.0023 to 0.1489, showing that values obtained using both methods were very coherent. B angular coefficient (5%) went from 0.9339 to 1.0745, and hence included value 1. This coefficient indicates that a certain increase in the morphometric value corresponds to the same value obtained using score data, when we consider the cavity size.

Discrepancies were relatively higher when microleakage values were very low to be visually detected and generally corresponded to score 0 (no dye penetration). In some of these cases, the morphometric method detected a small dye penetration, which led to these discrepancies. Nevertheless, statistical analysis proved that there is a highly significant correlation between the two methods. Therefore, when equipment is available, the morphometric analysis can be used with great reliability, although the visual method revealed to be practical and efficient to evaluate microleakage, also showing that the subjectivity attributed to it does not influence the results.

Regarding adhesive systems, the ABF experimental (Table 1) showed a superior sealing ability than did Single Bond. Probably, bonding penetration occurred at the same depth as the demineralization obtained using acidic monomers11,25, so that the risk of incomplete impregnation with the bonding resin does not exist, thus guarantying the marginal sealing observed in this study. As in previous studies11, Single Bond presented higher microleakage when compared to the self-etching primer systems, possibly as a result of incomplete monomer penetration in the demineralized dentin zone obtained following phosphoric acid etching3,11,12,27.

The greater microleakage obtained using Single Bond can also be explained by the fact that its bonding mechanism is based on the total removal of the smear layer following etching with phosphoric acid, which leaves an exposed collagen network available for primer impregnation. Primer application must be made after slight drying, leaving dentin sufficiently moist to prevent collapse of this collagen network22,25,27. Due to the difficulties in verifying the ideal moisture to be left in dentin17,22,27, marginal integrity could be compromised, resulting in higher levels of microleakage.

The idea of adhesives containing acidic monomers is very interesting as, in addition to obtaining excellent results, it renders the technique simpler and less sensitive. Clinically, the reduction of such a critical operative step as etching with phosphoric acid, which requires careful washing and drying, minimizes the possibility of post-operative sensitivity, as marginal sealing is improved1,3,11-13,27.

Once marginal sealing is obtained, it is expected that it will be maintained for many years, guarantying the longevity of a restoration. However, the bonding interface is constantly in contact with saliva and consequently subjected to degradation in the oral cavity, especially in cases of incomplete monomer penetration through the demineralized dentin9,11,21. Moreover, if incomplete polymerization of resin monomers occurs, they can be washed out, leaving spaces in the polymeric matrix, which becomes soaked with water, and thus facilitates degradation2,7,9,11.

Some studies have already reported that bond strength decreases following long periods of storage in water2,7,16, and that the collagen layer presents higher porosity when analyzed using scanning electron microscopy, even after 6 months21. Considering this possible degradation, it is important to evaluate the performance of restorative materials after different storage periods. As in other studies11,16, the period evaluated in the present study (3 months) was not enough to allow bonding degradation and consequently higher microleakage (Table 2). Li et al.11 (2001) found differences on microleakage results only after a storage period of 6 months. Hence, it is evident that more studies are necessary with longer storage periods to evaluate the longevity of these materials.

CONCLUSIONS

Based on the results obtained in this study, the following conclusions can be drawn:

1. The visual method of evaluation using calibrated examiners and data transformation allowed us to obtain the same conclusions as with the morphometric method, which is technologically more sophisticated.

2. The ABF experimental self-etching primer adhesive system presented significantly lower values of microleakage than did the Single Bond one-bottle system, either in the immediate assessment (24 hours) or after 3 months of storage in water.

3. The storage period of 3 months produced microleakage results similar to those produced after the 24 hour period, thus pointing out that the former is not enough to allow degradation of the bonding interface.

Acknowledgements

The authors gratefully acknowledge Paulo Santos for the preliminary drawings, and KG Sorensen, Kuraray Medical Inc., Japan and 3M ESPE for the supply of materials. We also wish to thank the Laboratory of Informatics for the Development of Dentistry (Laboratório de Informática para Desenvolvimento da Odontologia - LIDO), School of Dentistry, University of São Paulo, and the Nucleus for Supporting Research in Dental Materials (Núcleo de Apoio à Pesquisa em Materiais Dentários - NAPEM).

Recebido para publicação em 11/09/02

Enviado para reformulação em 21/02/03

Aceito para publicação em 21/05/03

  • 1
    1. Bouillaguet S, Gysi P, Wataha JC, Ciucchi B, Cattani M, Godin C, et al. Bond strength of composite to dentin using conventional, one-step, and self-etching adhesive systems. J Dent 2001;29:55-61.
  • 2
    2. Burrow MF, Satoh M, Tagami J. Dentin bonding durability after three years using a dentin bonding agent with and without priming. Dent Mater 1996;12:302-7.
  • 3
    3. Christensen GJ. Self-etching primers are here. J Am Dent Assoc 2001;132:1041-3.
  • 4
    4. Déjou J, Sindres V, Camps J. Influence of criteria on the results of in vitro evaluation of microleakage. Dent Mater 1996;12:342-49.
  • 5
    5. Ferrari M. Sealing ability of last generation of adhesive-restorative materials placed on vital teeth. Trans Acad Dent Mater 1998;12:75-102.
  • 6
    6. Formolo E, Sartori A, Demarco F. Infiltração marginal em cavidades de classe V com o uso de diferentes materiais adesivos. RPG Rev Pos Grad 2001;8:306-12.
  • 7
    7. Gwinnett AJ, Yu S. Effect of long-term water storage on dentin bonding. Am J Dent 1995;8:109-11.
  • 8
    8. Hilton TJ. Can modern restorative procedures and materials reliably seal cavities? In vitro investigations. Trans Acad Dent Mater 1998;12:21-71.
  • 9
    9. Kitasako Y, Burrow MF, Nikaido T, Tagami J. Long-term tensile bond durability of two different 4-META containing resin cements to dentin. Dent Mater 2002;18:276-80.
  • 10
    10. Koibuchi H, Yasuda N, Nakabayashi N. Bonding to dentin with a self-etching primer: the effect of smear layers. Dent Mater 2001;17:122-6.
  • 11
    11. Li HP, Burrow MF, Tyas MJ. The effect of long-term storage on nanoleakage. Oper Dent 2001;26:609-16.
  • 12
    12. Lucena-Martín C, González-Rodriguez MP, Ferrer-Luque CM, Robles-Gijón V, Navajas JM. Influence of time and thermocycling on marginal sealing of several dentin adhesive systems. Oper Dent 2001;26:550-5.
  • 13
    13. Manhart J, Chen HY, Mehl A, Weber K, Hickel R. Marginal quality and microleakage of adhesive class V restorations. J Dent 2001;29:123-30.
  • 14
    14. Milia E, Lallai MR, Garcia-Godoy F. In vivo effect of a self-etching primer on dentin. Am J Dent 1999;12:167-71.
  • 15
    15. Miranda Jr WG. Avaliação in vitro da infiltração nas caixas proximais de pré-molares humanos restaurados com diferentes adesivos universais e resinas compostas. [Tese de Doutorado] São Paulo: Faculdade de Odontologia da USP; 1994.
  • 16
    16. Okuda M, Pereira PNR, Nakajima M, Tagami J. Relationship between nanoleakage and long-term durability of dentin bonds. Oper Dent 2001;26:482-90.
  • 17
    17. Pereira GDS, Paulillo LAMS, De Goes MF, Dias CTS. How wet should dentin be? Comparison of methods to remove excess water during moist bonding. J Adhes Dent 2001; 3:257-64.
  • 18
    18. Raskin A. Reliability of dye penetration for microleakage evaluation: influence of sections number. Trans Acad Dent Mater 1998;12:212.
  • 19
    19. Raskin A, D’Hoore W, Gonthier S, Degrange M, Déjou J. Reliability of in vitro microleakage tests: a literature review. J Adhes Dent 2001;4:295-8.
  • 20
    20. Sano H, Takatsu T, Ciucchi, B, Horner JA, Matthews WG, Pashley DH. Nanoleakage: leakage within the hybrid layer. Oper Dent 1995;20:18-25.
  • 21
    21. Sano H, Toshikawa T, Pereira PNR, Kanemura N, Morigami M, Tagami J, et al. Long-term durability of dentin bonds made with a self-etching primer, in vivo. J Dent Res 1999;78:906-11.
  • 22
    22. Santini A, Mitchell S. Effect of wet and dry bonding techniques on marginal leakage. Am J Dent 1998;11:219-24.
  • 23
    23. Tapety CMC. Influência da interposição de bases na infiltração marginal em cavidades classe II (MOD), restauradas com resinas compostas para dentes posteriores. [Dissertação de Mestrado] Bauru: Faculdade de Odontologia da USP; 2000.
  • 24
    24. Tay FR, Gwinnett AJ, Wei SH. The overwet phenomenon: a scanning electron microscopic study of the surface moisture in the acid-conditioned, resin-dentin interface. Am J Dent 1996;9:109-14.
  • 25
    25. Tay FR, Pashley DH. Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers. Dent Mater 2001;17:296-308.
  • 26
    26. Ulson RCB. Avaliação da microinfiltração, utilizando diversos sistemas adesivos, em restaurações de molares decíduos. [Dissertação de Mestrado] São Paulo: Faculdade de Odontologia da USP; 2000.
  • 27
    27. Unemori M, Matsuya Y, Akashi A, Goto Y, Akamine A. Composite resin restoration and postoperative sensitivity: clinical follow-up in an undergraduate program. J Dent 2001;29:7-13.
  • †
    Study carried out in the Discipline of Experimental Design and Laboratorial Research Technique, Department of Dental Materials, School of Dentistry, University of São Paulo.
  • Publication Dates

    • Publication in this collection
      18 Dec 2003
    • Date of issue
      Sept 2003

    History

    • Accepted
      21 May 2003
    • Reviewed
      21 Feb 2003
    • Received
      11 Sept 2002
    Sociedade Brasileira de Pesquisa Odontológica e Faculdade de Odontologia da Universidade de São Paulo Avenida Lineu Prestes, 2227 - Caixa Postal 8216, Cidade Universitária Armando de Salles Oliveira, 05508-900 São Paulo SP - Brazil, Telefone/Fax: (55 11) 3091-7855 - São Paulo - SP - Brazil
    E-mail: pob@edu.usp.br