Acessibilidade / Reportar erro

Ischemia modified albumin: does it change during pneumoperitoneum in robotic prostatectomies?

ABSTRACT

Background

The unique positioning of the patient at steep Trendelenburg with prolonged and increased intra-abdominal pressure (IAP) during robotic radical prostatectomy may increase the risk of splanchnic ischemia. We aimed to investigate the acute effects of IAP and steep Trendelenburg position on the level of ischemia modified albumin (IMA) and to test if serum IMA levels might be used as a surrogate marker for possible covert ischemia during robotic radical prostatectomies.

Patients and Methods

Fifty ASA I-II patients scheduled for elective robotic radical prostatectomy were included in this investigation.

Exclusion criteria

The patients were excluded from the study when an arterial cannulation could not be accomplished, if the case had to be converted to open surgery or if the calculated intraoperative bleeding exceeded 300ml. All the patients were placed in steep (45 degrees) Trendelenburg position following trocar placement. Throughout the operation the IAP was maintained between 11-14mmHg. Mean arterial blood pressure (MAP), cardiac output (CO) were continuously monitored before the induction and throughout the surgery. Blood gases, electrolytes, urea, creatinine, alanine transferase (ALT), aspartate transferase (AST) were recorded. Additionally, IMA levels were measured before, during and after surgery.

Results

(1) MAP, CO, lactate and hemoglobin (Hb) did not significantly change in any period of surgery (p>0.05); (2) sodium (p<0.01), potassium (p<0.05) and urea (p<0.05) levels decreased at postoperative period, and no significant changes at creatinine, AST, ALT levels were observed in these patients; (3) At the end of surgery (180 min) pCO2, pO2, HCO3 and BE did not change compared to after induction values (p>0.05) but mild acidosis was present in these patients (p<0.01 vs. after induction); (4) IMA levels were found to be comparable before induction (0.34±0.04), after induction (0.31±0.06) and at the end of surgery (0.29±0.05) as well.

Conclusion

We did not demonstrate any significant mesenteric-splanchnic ischemia which could be detected by serum IMA levels during robotic radical prostatectomies performed under steep Trendelenburg position and when IAP is maintained in between 11-14 mmHg

Ischemia; Albumins; Head-Down Tilt; Robotics; Prostatectomy

INTRODUCTION

Robot assistance in laparoscopic surgery has undoubtedly contributed to the advancement of minimally invasive oncologic surgery. Robotic surgery provides a number of potential benefits such as improvement in surgical precision, diminished blood loss, reduced postoperative pain, improved cosmetic outcome, shorter convalescence and hence improved patient satisfaction (11. Fuchs KH. Minimally invasive surgery. Endoscopy. 2002; 34:154-9., 22. Sullivan MJ, Frost EA, Lew MW. Anesthetic care of the patient for robotic surgery. Middle East J Anaesthesiol. 2008; 19:967-82.). Robot assisted laparoscopic radical prostatectomy (RARP) is the most frequently performed robotic procedure in urology. Despite the established advantages, there are several important issues related to the intra-operative management specific to this procedure. The positioning of patients during RARP impacts the risks related to hemodynamic changes such as increased systemic vascular resistance (SVR), mean arterial pressure (MAP), filling pressures and reduction in cardiac index (CI) (33. Hu JC, Nelson RA, Wilson TG, Kawachi MH, Ramin SA, Lau C, et al. Crocitto LE. Perioperative complications of laparoscopic and robotic assisted laparoscopic radical prostatectomy. J Urol. 2006; 175:541-6., 44. Nishanian E, Mets B. in R. Miller. Anesthesia for Robotic Surgery. ed, (2006) Anesthesia, 6th ed. Elsevier, New York; Chapter 66: pp. 2557-71.). High intra-abdominal pressure (IAP), especially if over 15mmHg, increases cerebral blood flow and intracranial pressure, while decreasing portal, hepatic vein flow and the total hepatic microcirculation (55. Joris JL, Noirot DP, Legrand MJ, Jacquet NJ, Lamy ML. Hemodynamic changes during laparoscopic cholecystectomy. Anesth Analg. 1993; 76:1067-71.

6. Smith I, Benzie RJ, Gordon NL, Kelman GR, Swapp GH. Cardiovascular effects of peritoneal insufflation of carbon dioxide for laparoscopy. Br Med J. 1971; 3:410-1.

7. Branche PE, Duperret SL, Sagnard PE, Boulez JL, Petit PL, Viale JP. Left ventricular loading modifications induced by pneumoperitoneum: a time course echocardiographic study. Anesth Analg. 1998; 86:482-7.
-88. Westerband A, Van De Water J, Amzallag M, Lebowitz PW, Nwasokwa ON, Chardavoyne R, et al. Cardiovascular changes during laparoscopic cholecystectomy. Surg Gynecol Obstet. 1992; 175:535-8.). Increased IAP furthermore decreases mesenteric blood flow and impedes gastrointestinal microcirculation (88. Westerband A, Van De Water J, Amzallag M, Lebowitz PW, Nwasokwa ON, Chardavoyne R, et al. Cardiovascular changes during laparoscopic cholecystectomy. Surg Gynecol Obstet. 1992; 175:535-8., 99. Johannsen G, Andersen M, Juhl B. The effect of general anaesthesia on the haemodynamic events during laparoscopy with CO2-insufflation. Acta Anaesthesiol Scand. 1989; 33:132-6.). The pneumoperitoneum (PP) similarly leads to decreased arterial and venous flow in renal medulla and cortex (1010. Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 1995; 39:949-55.

11. Walder AD, Aitkenhead AR. Role of vasopressin in the haemodynamic response to laparoscopic cholecystectomy. Br J Anaesth. 1997; 78:264-6.
-1212. De Cosmo G, Iannace E, Primieri P, Valente MR, Proietti R, Matteis M, Silvestrini M. Changes in cerebral hemodynamics during laparoscopic cholecystectomy. Neurol Res. 1999;21:658-60.).

The fixed positioning of the patients followed by the docking of the robot in steep Trendelenburg position and the relatively long duration of this procedure can thus cause excessive mechanical pressure over the gastrointestinal, respiratory and the cardiovascular systems, increase the risk of hypothermia, intensify the hemodynamic and respiratory adverse effects of the PP and may as well give rise to mesenteric-splanchnic hypoxic ischemia (44. Nishanian E, Mets B. in R. Miller. Anesthesia for Robotic Surgery. ed, (2006) Anesthesia, 6th ed. Elsevier, New York; Chapter 66: pp. 2557-71.).

Serum ischemia modified albumin (IMA) is a new, FDA approved biomarker of ischemia, and increases in patients with acute coronary syndrome (1313. Sinha MK, Roy D, Gaze DC, Collinson PO, Kaski JC. Role of “Ischemia modified albumin”, a new biochemical marker of myocardial ischaemia, in the early diagnosis of acute coronary syndromes. Emerg Med J. 2004; 21:29-34.

14. Roy D, Quiles J, Sharma R, Sinha M, Avanzas P, Gaze D, et al. Ischemia-modified albumin concentrations in patients with peripheral vascular disease and exercise-induced skeletal muscle ischemia. Clin Chem. 2004; 50:1656-60.

15. Gunduz A, Turedi S, Mentese A, Altunayoglu V, Turan I, Karahan SC, et al. Ischemia-modified albumin levels in cerebrovascular accidents. Am J Emerg Med. 2008; 26:874-8.
-1616. Gunduz A, Mentese A, Turedi S, Karahan SC, Mentese U, Eroglu O, et al. Serum ischaemia-modified albumin increases in critical lower limb ischaemia. Emerg Med J. 2008; 25:351-3.). IMA is produced during an ischemic attack and is present in blood in easily detectable concentrations (1313. Sinha MK, Roy D, Gaze DC, Collinson PO, Kaski JC. Role of “Ischemia modified albumin”, a new biochemical marker of myocardial ischaemia, in the early diagnosis of acute coronary syndromes. Emerg Med J. 2004; 21:29-34., 1717. Christenson RH, Duh SH, Sanhai WR, Wu AH, Holtman V, Painter P, et al. Characteristics of an Albumin Cobalt Binding Test for assessment of acute coronary syndrome patients: a multicenter study. Clin Chem. 2001; 47:464-70.

18. Wu AH, Morris DL, Fletcher DR, Apple FS, Christenson RH, Painter PC. Analysis of the Albumin Cobalt Binding (ACB) test as an adjunct to cardiac troponin I for the early detection of acute myocardial infarction. Cardiovasc Toxicol. 2001; 1:147-51.
-1919. Bhagavan NV, Lai EM, Rios PA, Yang J, Ortega-Lopez AM, Shinoda H, et al. Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction. Clin Chem. 2003; 49:581-5.). Hypoxia, acidosis and free radical production reduce the ability of human serum albumin to bind metals like cobalt to its N-terminus, which in turn causes IMA production. Endothelial or extracellular hypoxia, acidosis, and free oxygen radicals have been shown to cause IMA increase (2020. Erturk E, Cekic B, Geze S, Kosucu M, Coskun I, Eroglu A, et al. Comparison of the effect of propofol and N-acetyl cysteine in preventing ischaemia-reperfusion injury. Eur J Anaesthesiol. 2009; 26:279-84., 2121. Kanko M, Yavuz S, Duman C, Hosten T, Oner E, Berki T. Ischemia-modified albumin use as a prognostic factor in coronary bypass surgery. J Cardiothorac Surg. 2012; 7:3.), thus IMA can be detected early on the beginning of ischemia. Moreover IMA was found to increase in patients with mesenteric ischemia (2222. Gunduz A, Turedi S, Mentese A, Karahan SC, Hos G, Tatli O, et al. Ischemia-modified albumin in the diagnosis of acute mesenteric ischemia: a preliminary study. Am J Emerg Med. 2008; 26:202-5.). It has been identified as a helpful marker for determining the alterations in the splanchnic and the visceral blood flow during laparoscopic cholecystectomies (2323. Koksal H, Kurban S, Sahin M. The role of ischemia modified albumin in the evaluation of hemodynamic changes in the splanchnic area during laparoscopic cholecystectomy.Ulusal Cerrahi Dergisi. 2010; 26: 91-4.).

After myocardial ischemia, the serum levels of IMA rise within minutes and continue to increase for 6-12 hours, after which they return to normal (2424. Bar-Or D, Lau E, Winkler JV. A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report. J Emerg Med. 2000; 19:311-5.

25. Kadioğlu H, Kaptanoğlu L. The Use of Ischemia Modified Albumin in Emergency Surgery (Iskemik Modifiye Albüminin Acil Cerrahide Kullanimi). J Kartal TR. 2012;23:106-9.

26. Dekker MS, Mosterd A, van ‘t Hof AW, Hoes AW. Novel biochemical markers in suspected acute coronary syndrome: systematic review and critical appraisal. Heart. 2010; 96:1001-10.

27. Christenson RH, Duh SH, Sanhai WR, Wu AH, Holtman V, Painter P, et al. Characteristics of an Albumin Cobalt Binding Test for assessment of acute coronary syndrome patients: a multicenter study. Clin Chem. 2001; 47:464-70.
-2828. Gidenne S, Ceppa F, Fontan E, Perrier F, Burnat P. Analytical performance of the Albumin Cobalt Binding (ACB) test on the Cobas MIRA Plus analyzer. Clin Chem Lab Med. 2004; 42:455-61.). Increase in IMA concentrations has also been shown to indicate tissue ischemia in other conditions such as peripheral vascular disease, exercise-induced skeletal muscle ischemia, end-stage renal disease patients on haemodialysis, acute stroke, calf-muscle ischemia (2929. Roy D, Quiles J, Sharma R, Sinha M, Avanzas P, Gaze D, et al. Ischemia-modified albumin concentrations in patients with peripheral vascular disease and exercise-induced skeletal muscle ischemia. Clin Chem. 2004; 50:1656-60.

30. Kiyici A, Mehmetoğlu I, Karaoğlan H, Atalay H, Solak Y, Türk S. Ischemia-modified albumin levels in patients with end-stage renal disease patients on hemodialysis: does albumin analysis method affect albumin-adjusted ischemia-modified albumin levels? J Clin Lab Anal. 2010; 24:273-7.

31. Abboud H, Labreuche J, Meseguer E, Lavallee PC, Simon O, Olivot JM, et al. Ischemia-modified albumin in acute stroke. Cerebrovasc Dis. 2007; 23:216-20.

32. Apple FS, Quist HE, Otto AP, Mathews WE, Murakami MM. Release characteristics of cardiac biomarkers and ischemia-modified albumin as measured by the albumin cobalt-binding test after a marathon race. Clin Chem. 2002; 48:1097-100.
-3333. Falkensammer J, Stojakovic T, Huber K, Hammerer-Lercher A, Gruber I, Scharnagl H, et al. Serum levels of ischemia-modified albumin in healthy volunteers after exercise-induced calf-muscle ischemia. Clin Chem Lab Med. 2007; 45:535-40.).

In the present study, we aimed to investigate the acute effects of IAP and steep Trendelenburg position on the level of ischemia modified albumin (IMA) and to test if serum IMA levels might be used as a surrogate marker for possible covert ischemia during robotic radical prostatectomies.

MATERIALS AND METHODS

Local ethics committee approval for this study (ATADEK No: 2013-456/B.30.2.ACU.0.00.00.050-06) was provided by ATADEK, Acibadem University, Ethics Committee, Istanbul, Turkey on 01 February 2013.

Fifty male patients, aged 55-75 years, ASA I-II, scheduled for RARP were included in the study and informed consents were taken.

Exclusion Criteria: The patients were excluded from the study when an arterial cannulation could not be accomplished, if the case had to be converted to open surgery or if the calculated intraoperative bleeding exceeded 300ml.

General Procedure

All patients were pre-medicated with midazolam 0.05mg/kg intravenously (i.v.) and standard monitorization, including, electrocardiography (ECG), invasive blood pressure (IBP), pulse oximetry (SpO2), regional cerebral oxygenation (rSO2), cardiac output (CO), and end tidal carbon dioxide (ETCO2), was applied. Anaesthesia induction was performed by propofol 2.5-3.5mg/kg, remifentanil 1mic/kg i.v. and muscle relaxation was performed by rocuronium bromide 0.6mg/kg i.v. bolus and infusion 4-15mcg/kg/min. Anaesthesia was maintained by remifentanil 0.025-0.05mic/kg/min i.v.infusion and by sevoflurane 0.8-1% in O2:N2O/40:60 in all patients. PEEP was adjusted between 4.6-4.8mmHg. The patients were placed in steep Trendelenburg position (45 degrees head-down angulation) after trocar placement and until the robot was un-docked. The IAP was maintained between 11-14mmHg throughout the laparoscopic stage of the operation.

MAP and CO were measured constantly as systemic hemodynamic parameters and recorded at particular instants: (11. Fuchs KH. Minimally invasive surgery. Endoscopy. 2002; 34:154-9.) before induction (BI); (22. Sullivan MJ, Frost EA, Lew MW. Anesthetic care of the patient for robotic surgery. Middle East J Anaesthesiol. 2008; 19:967-82.) after induction (AI); (33. Hu JC, Nelson RA, Wilson TG, Kawachi MH, Ramin SA, Lau C, et al. Crocitto LE. Perioperative complications of laparoscopic and robotic assisted laparoscopic radical prostatectomy. J Urol. 2006; 175:541-6.) 5thmin; (44. Nishanian E, Mets B. in R. Miller. Anesthesia for Robotic Surgery. ed, (2006) Anesthesia, 6th ed. Elsevier, New York; Chapter 66: pp. 2557-71.) 60thmin; (55. Joris JL, Noirot DP, Legrand MJ, Jacquet NJ, Lamy ML. Hemodynamic changes during laparoscopic cholecystectomy. Anesth Analg. 1993; 76:1067-71.) 90thmin; (66. Smith I, Benzie RJ, Gordon NL, Kelman GR, Swapp GH. Cardiovascular effects of peritoneal insufflation of carbon dioxide for laparoscopy. Br Med J. 1971; 3:410-1.) 120thmin; (77. Branche PE, Duperret SL, Sagnard PE, Boulez JL, Petit PL, Viale JP. Left ventricular loading modifications induced by pneumoperitoneum: a time course echocardiographic study. Anesth Analg. 1998; 86:482-7.) 150thmin; (88. Westerband A, Van De Water J, Amzallag M, Lebowitz PW, Nwasokwa ON, Chardavoyne R, et al. Cardiovascular changes during laparoscopic cholecystectomy. Surg Gynecol Obstet. 1992; 175:535-8.) 180thmin of PP. Arterial blood levels of lactate, hemoglobin, pH, pCO2, pO2, HCO3- and base access were monitored at same intervals. Additionally, serum sodium, potassium, blood urea nitrogen (BUN), creatinine, alanine transferase (ALT) and aspartate transferase (AST) were assessed preoperatively and postoperatively. Blood was sampled for interim measurements of serum ischemia modified albumin levels before induction (BI), after induction (AI) and the end of surgery (ES). The serum samples were stored at -20 degrees until they were sent to laboratory for IMA quantification. All of the serum samples for IMA measurements remained intact.

Determination of Ischemia modified Albumin (IMA)

IMA levels were determined according to the method defined by Bar-Or et al. (2424. Bar-Or D, Lau E, Winkler JV. A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report. J Emerg Med. 2000; 19:311-5.). Briefly, 200uL serum was added to 50uL 0. 1% (w/v) cobalt chloride (Sigma Aldrich, St. Louis, MO; CoCl2.6H2O). After gentle shaking, 10 minutes were waited to allow cobalt binding to albumin. Then 50uL dithiothreitol (DTT) (Sigma) was added as a colouring agent. As control, 50uL of distilled water was used instead of DTT. After 2 minutes, 1mL of 0.9% NaCl was added to stop the reaction, and the absorbance at 470nm was determined using a spectrophotometer (2424. Bar-Or D, Lau E, Winkler JV. A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report. J Emerg Med. 2000; 19:311-5.). The difference of absorbance units between control and DTT samples were recorded. The results were quantified as absorbance unit (ABSU) and values greater than 0.400 ABSU were accepted as showing lower binding capacity for cobalt, therefore indicative of ischemia, whereas values lower than 0.400 ABSU were interpreted as lack of ischemia (2424. Bar-Or D, Lau E, Winkler JV. A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report. J Emerg Med. 2000; 19:311-5., 2525. Kadioğlu H, Kaptanoğlu L. The Use of Ischemia Modified Albumin in Emergency Surgery (Iskemik Modifiye Albüminin Acil Cerrahide Kullanimi). J Kartal TR. 2012;23:106-9.).

Statistical analysis

Outcomes were reported as the mean±SEM. Statistical analysis was performed using GraphPad Prism version 5.0 for Windows (GraphPad Software, La Jolla, Calif). Results were compared using repeated measures ANOVA-tukey post hoc test used and a p-value of <0.05 was considered statistically significant.

RESULTS

The descriptive characteristics of patients and duration of surgery is summarized in Table-1.

Table 1
Characteristics of the patients and duration of pneumoperitoneum(PP).

Systemic hemodynamics results

The systemic hemodynamic values are presented in Figure-1. Induction of anaesthesia did not cause a statistically significant effect on MAP (p>0.05). Likewise, CO values were not affected by anaesthesia. At any time of surgery, both MAP and CO values were found to be similar compared to their respective levels after anaesthesia induction (p>0.05).

Figure 1
Systemic hemodynamic parameters.

Blood gases analysis results

Blood gasses and related parameters are presented in Figure-2 and Table-2. The arterial pH was more acidotic at the 150th and 180thmin of PP when compared to 5thmin of PP. pCO2 values were also found higher concurrently. pO2 values were higher preoperatively than the pre-induction values during PP. While HCO3- level was not statistically different, base excess (BE) levels were higher at 60th, 120th and 180thmin. Hemoglobin and lactate values were not statistically altered during the operation.

Figure 2
Lactate and hemoglobin values at all-time points.

Table 2
Blood Gases parameters.

Routine biochemistry and plasma electrolyte results

Plasma ions, urea, creatinine, ALT, AST levels are presented in Table-3. Postoperative levels of sodium, potassium and urea were lower (p<0.01, p<0.05, p<0.05; respectively), whereas, postoperative levels of creatinine, ALT and AST were not different from the preoperative values (p>0.05).

Table 3
Routine blood chemistry parameters .

IMA levels results

IMA assessments at three time intervals are presented in Figure-3. Mean IMA (ABS unit) values were 0.34±0.04, 0.31±0.06 and 0.29±0.05. The variances between intervals were not found to be statistically significant (p>0.05) (Figure-3).

Figure 3
Serum IMA levels at three time points (BI: Before induction, AI: After induction, ES: End of surgery).

DISCUSSION

RARP is performed while the patient is uniquely placed in a 45 degrees head-down (Trendelenburg) position and requires CO2 insufflation to maintain an IAP of 12-15mmHg. We designed this study to investigate a hypothesis that even with a standard IAP, some form of mesenteric-splanchnic injury might be induced due to an extra gravitational pressure or a traction force caused by the exclusive fixed patient-positioning in addition to the duration of robot-assisted laparoscopic radical prostatectomy. We have come up with a hypothesis of a possible mesenteric-splanchnic injury during RARP subsequent to a simple observation of frequent and prolonged post-operative ileus in patients undergoing this operation. Our purpose was to assess the acute effects of IAP at steep Trendelenburg position during this operation by hemodynamic monitorization, blood gas and electrolyte analyses and utilizing serum IMA as a biomarker for a supposedly overlooked mesenteric-splanchnic ischemia during robotic prostatectomies. However, our research failed to suggest any significant association of this exclusive patient positioning or variances of IAP levels with mesenteric-splanchnic ischemia as assessed by means of serum IMA during robotic radical prostatectomy.

Previous studies evaluating the course of cardiovascular changes during PP pointed out that the CI gradually increased and systemic vascular resistance decreased 10 minutes after CO2 insufflation (3535. Ho HS, Saunders CJ, Gunther RA, Wolfe BM. Effector of hemodynamics during laparoscopy: CO2 absorption or intra-abdominal pressure? J Surg Res. 1995; 59:497-503.

36. Westerband A, Van De Water J, Amzallag M, Lebowitz PW, Nwasokwa ON, Chardavoyne R, et al. Cardiovascular changes during laparoscopic cholecystectomy. Surg Gynecol Obstet. 1992; 175:535-8.
-3737. Johannsen G, Andersen M, Juhl B. The effect of general anaesthesia on the haemodynamic events during laparoscopy with CO2-insufflation. Acta Anaesthesiol Scand. 1989; 33:132-6.). Additionally other studies suggested that CO rate decreased by 10-30% in Trendelenburg position (3737. Johannsen G, Andersen M, Juhl B. The effect of general anaesthesia on the haemodynamic events during laparoscopy with CO2-insufflation. Acta Anaesthesiol Scand. 1989; 33:132-6.

38. Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 1995; 39:949-55.
-3939. Lestar M, Gunnarsson L, Lagerstrand L, Wiklund P, Odeberg-Wernerman S. Hemodynamic perturbations during robot-assisted laparoscopic radical prostatectomy in 45° Trendelenburg position. Anesth Analg. 2011; 113:1069-75.). On the other hand, the mean CO level stayed stable (between 2.4-3.8L/min) in our study. It decreased to 2.4L/min at 5 minutes of PP but this change was statistically insignificant.

Lestar et al. examined the circulatory effects of an extreme Trendelenburg position (45º) on patients during robot-assisted laparoscopic radical prostatectomy and reported an almost 3-fold increase in central venous pressure compared with the initial value. MAP was increased by 35% in this study whereas heart rate (HR), stroke volume (SV), CO, and mixed venous oxygen saturation were unaffected during surgery, as were echocardiographic heart dimensions. In the horizontal position after PP exsufflation, filling pressures and MAP returned to baseline levels (3838. Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 1995; 39:949-55.).

In another study designed to evaluate hemodynamic changes associated with head-down positioning and prolonged PP during RARP, invasive hemodynamic parameters were measured by transpulmonary arterial thermodilution using the PiCCO system with a femoral artery catheter, CI, HR, MAP, systemic vascular resistance index, intrathoracic blood volume, and central venous pressure were recorded with the patient in the supine position, after head-down tilt, intraoperatively after 30 min, 1h, 2hs, 3hs, and 4hs of PP at an insufflation pressure of 12mmHg. Placing the patient in the Trendelenburg position caused a significant increase in CVP, whereas all other hemodynamic parameters remained nearly unaffected. The induction of PP resulted in a significant increase in MAP whereas no other parameter was affected. Even at 4 hours of PP, only mild hemodynamic changes were observed (3838. Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 1995; 39:949-55.). In our study, MAP was lower compared to pre-induction values throughout the operation, except a slight but statistically insignificant increase after PP. In our study, we did not prefer the use of invasive cardiac control.

In the present study, the IAP was 14mmHg at the start of PP and then maintained around 11mmHg for a mean duration of 3 hours. Post-operative levels of AST, ALT were not statistically different compared to the preoperative values. In an animal study assessing the effect of prolonged PP on liver function and perfusion, it was found that the liver sustained no damage due to prolonged PP during laparoscopic surgery. In that study, the IAP was maintained at 14mmHg and the mean operation time was 6 hours (3434. Hoekstra LT, Ruys AT, Milstein DM, van Samkar G, van Berge Henegouwen MI, Heger M, et al. Effects of prolonged pneumoperitoneum on hepatic perfusion during laparoscopy. Ann Surg. 2013; 257:302-7.).

In our study Group, the blood pH values were significantly lower at 150thmin and 180th min of PP than other intervals. At the same periods, pCO2 was also significantly higher compared to those measurements at other times. This can be explained by increased CO2 absorption during that time intervals of PP. In a study assessing the acid-base status and hemodynamic changes during PP, it was reported that there was a significant absorption of CO2 gas across the peritoneum which caused substantial acidemia and hypercapnia, which is also consistent with our results. In that study by Ho et al., the IAP did not affect metabolic function, acid-base balance or hemodynamics (3333. Falkensammer J, Stojakovic T, Huber K, Hammerer-Lercher A, Gruber I, Scharnagl H, et al. Serum levels of ischemia-modified albumin in healthy volunteers after exercise-induced calf-muscle ischemia. Clin Chem Lab Med. 2007; 45:535-40.). The investigators installed an IAP of 7 and 14mmHg each for 30 minutes to test the IAP ranges for laparoscopic procedures which elicited splanchnic and pulmonary hemodynamic and metabolic changes (3333. Falkensammer J, Stojakovic T, Huber K, Hammerer-Lercher A, Gruber I, Scharnagl H, et al. Serum levels of ischemia-modified albumin in healthy volunteers after exercise-induced calf-muscle ischemia. Clin Chem Lab Med. 2007; 45:535-40.). The effect of low IAP (7mmHg) on splanchnic perfusion was pointed out to be minimal whereas higher IAPs (14mmHg) decreased the portal and hepatic blood flow, lowered the hepatic and intestinal tissue pH. In our study, the IAPs were kept in the range of 11-14mmHg throughout the operations and we found no statistically significant increase in IMA levels, which would have indicated ischemia.

In a study evaluating the effects of PP on mesenteric ischemia-reperfusion injury by measuring intestinal tissue oxygen pressure (PtiO2) and oxidative damage during laparoscopic and open colon surgery, the authors found that during laparoscopic surgery, there was a significant decrease of PtiO2 only when PP was increased to 15mmHg. Although malondialdehyde (MDA) significantly increased in both Groups after mesentery traction and at the end of operation versus baseline levels, there was no difference between techniques (3939. Lestar M, Gunnarsson L, Lagerstrand L, Wiklund P, Odeberg-Wernerman S. Hemodynamic perturbations during robot-assisted laparoscopic radical prostatectomy in 45° Trendelenburg position. Anesth Analg. 2011; 113:1069-75.). When the effects of prolonged PP (44. Nishanian E, Mets B. in R. Miller. Anesthesia for Robotic Surgery. ed, (2006) Anesthesia, 6th ed. Elsevier, New York; Chapter 66: pp. 2557-71. hours) during RARP were investigated, it was found that MDA concentrations were significantly elevated at various intervals as compared with the pre-insufflation value and also the intra-mucosal pH value decreased significantly after CO2 insufflation compared with the pre-insufflation values. It was concluded that prolonged PP in RALP resulted in decreased splanchnic blood flow and PP itself produced oxidative stress (4040. Windberger UB, Auer R, Keplinger F, Längle F, Heinze G, Schindl M, et al. The role of intra-abdominal pressure on splanchnic and pulmonary hemodynamic and metabolic changes during carbon dioxide pneumoperitoneum. Gastrointest Endosc. 1999; 49:84-91.). In our study, PP lasted 3.5 hours and the difference between pre- and postoperative IMA values was not statistically significant. Therefore, no ischemia was detected by measuring IMA.

Our findings did not reveal any renal injury as there was no significant statistical difference between the preoperative and postoperative BUN and creatinine values, unlike the study of Bishara et al., where renal perfusion and function were decreased by induction of IAP of 14mmHg (4141. Gianotti L, Nespoli L, Rocchetti S, Vignali A, Nespoli A, Braga M. Gut oxygenation and oxidative damage during and after laparoscopic and open left-sided colon resection: a prospective, randomized, controlled clinical trial. Surg Endosc. 2011; 25:1835-43.).

The maintenance of the IAP within 11-14mmHg during the RARP operations is necessary in order to avoid the complications of PP. This safety measure certainly protects the patients from the adverse effects of high IAP. The restriction of IAP might be considered a limitation for this clinical study, and the sensitivity of IMA as an ischemic biomarker can further be tested by designing animal studies where IAP may be increased to higher levels. Further studies may as well be performed utilizing novel biomarkers to identify whether there are any mesenteric compartment like syndromes during RARP.

Based upon the findings obtained as a result of current study; although patients were kept in steep (45 degrees) Trendelenburg position during robotic prostatectomies, IAP between 11-14mmHg does not cause any hypoxia/ischemia detected by conventional measurement techniques. Even if there is a hypoxia, which is out of detection limits, this cannot be followed by serum IMA levels.

In conclusion, during robotic radical prostatectomies performed under steep Trendelenburg position and when IAP is maintained in between 11-14mmHg, we did not demonstrate any significant mesenteric-splanchnic ischemia that could be detected by serum IMA levels.

REFERENCES

  • 1
    Fuchs KH. Minimally invasive surgery. Endoscopy. 2002; 34:154-9.
  • 2
    Sullivan MJ, Frost EA, Lew MW. Anesthetic care of the patient for robotic surgery. Middle East J Anaesthesiol. 2008; 19:967-82.
  • 3
    Hu JC, Nelson RA, Wilson TG, Kawachi MH, Ramin SA, Lau C, et al. Crocitto LE. Perioperative complications of laparoscopic and robotic assisted laparoscopic radical prostatectomy. J Urol. 2006; 175:541-6.
  • 4
    Nishanian E, Mets B. in R. Miller. Anesthesia for Robotic Surgery. ed, (2006) Anesthesia, 6th ed. Elsevier, New York; Chapter 66: pp. 2557-71.
  • 5
    Joris JL, Noirot DP, Legrand MJ, Jacquet NJ, Lamy ML. Hemodynamic changes during laparoscopic cholecystectomy. Anesth Analg. 1993; 76:1067-71.
  • 6
    Smith I, Benzie RJ, Gordon NL, Kelman GR, Swapp GH. Cardiovascular effects of peritoneal insufflation of carbon dioxide for laparoscopy. Br Med J. 1971; 3:410-1.
  • 7
    Branche PE, Duperret SL, Sagnard PE, Boulez JL, Petit PL, Viale JP. Left ventricular loading modifications induced by pneumoperitoneum: a time course echocardiographic study. Anesth Analg. 1998; 86:482-7.
  • 8
    Westerband A, Van De Water J, Amzallag M, Lebowitz PW, Nwasokwa ON, Chardavoyne R, et al. Cardiovascular changes during laparoscopic cholecystectomy. Surg Gynecol Obstet. 1992; 175:535-8.
  • 9
    Johannsen G, Andersen M, Juhl B. The effect of general anaesthesia on the haemodynamic events during laparoscopy with CO2-insufflation. Acta Anaesthesiol Scand. 1989; 33:132-6.
  • 10
    Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 1995; 39:949-55.
  • 11
    Walder AD, Aitkenhead AR. Role of vasopressin in the haemodynamic response to laparoscopic cholecystectomy. Br J Anaesth. 1997; 78:264-6.
  • 12
    De Cosmo G, Iannace E, Primieri P, Valente MR, Proietti R, Matteis M, Silvestrini M. Changes in cerebral hemodynamics during laparoscopic cholecystectomy. Neurol Res. 1999;21:658-60.
  • 13
    Sinha MK, Roy D, Gaze DC, Collinson PO, Kaski JC. Role of “Ischemia modified albumin”, a new biochemical marker of myocardial ischaemia, in the early diagnosis of acute coronary syndromes. Emerg Med J. 2004; 21:29-34.
  • 14
    Roy D, Quiles J, Sharma R, Sinha M, Avanzas P, Gaze D, et al. Ischemia-modified albumin concentrations in patients with peripheral vascular disease and exercise-induced skeletal muscle ischemia. Clin Chem. 2004; 50:1656-60.
  • 15
    Gunduz A, Turedi S, Mentese A, Altunayoglu V, Turan I, Karahan SC, et al. Ischemia-modified albumin levels in cerebrovascular accidents. Am J Emerg Med. 2008; 26:874-8.
  • 16
    Gunduz A, Mentese A, Turedi S, Karahan SC, Mentese U, Eroglu O, et al. Serum ischaemia-modified albumin increases in critical lower limb ischaemia. Emerg Med J. 2008; 25:351-3.
  • 17
    Christenson RH, Duh SH, Sanhai WR, Wu AH, Holtman V, Painter P, et al. Characteristics of an Albumin Cobalt Binding Test for assessment of acute coronary syndrome patients: a multicenter study. Clin Chem. 2001; 47:464-70.
  • 18
    Wu AH, Morris DL, Fletcher DR, Apple FS, Christenson RH, Painter PC. Analysis of the Albumin Cobalt Binding (ACB) test as an adjunct to cardiac troponin I for the early detection of acute myocardial infarction. Cardiovasc Toxicol. 2001; 1:147-51.
  • 19
    Bhagavan NV, Lai EM, Rios PA, Yang J, Ortega-Lopez AM, Shinoda H, et al. Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction. Clin Chem. 2003; 49:581-5.
  • 20
    Erturk E, Cekic B, Geze S, Kosucu M, Coskun I, Eroglu A, et al. Comparison of the effect of propofol and N-acetyl cysteine in preventing ischaemia-reperfusion injury. Eur J Anaesthesiol. 2009; 26:279-84.
  • 21
    Kanko M, Yavuz S, Duman C, Hosten T, Oner E, Berki T. Ischemia-modified albumin use as a prognostic factor in coronary bypass surgery. J Cardiothorac Surg. 2012; 7:3.
  • 22
    Gunduz A, Turedi S, Mentese A, Karahan SC, Hos G, Tatli O, et al. Ischemia-modified albumin in the diagnosis of acute mesenteric ischemia: a preliminary study. Am J Emerg Med. 2008; 26:202-5.
  • 23
    Koksal H, Kurban S, Sahin M. The role of ischemia modified albumin in the evaluation of hemodynamic changes in the splanchnic area during laparoscopic cholecystectomy.Ulusal Cerrahi Dergisi. 2010; 26: 91-4.
  • 24
    Bar-Or D, Lau E, Winkler JV. A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report. J Emerg Med. 2000; 19:311-5.
  • 25
    Kadioğlu H, Kaptanoğlu L. The Use of Ischemia Modified Albumin in Emergency Surgery (Iskemik Modifiye Albüminin Acil Cerrahide Kullanimi). J Kartal TR. 2012;23:106-9.
  • 26
    Dekker MS, Mosterd A, van ‘t Hof AW, Hoes AW. Novel biochemical markers in suspected acute coronary syndrome: systematic review and critical appraisal. Heart. 2010; 96:1001-10.
  • 27
    Christenson RH, Duh SH, Sanhai WR, Wu AH, Holtman V, Painter P, et al. Characteristics of an Albumin Cobalt Binding Test for assessment of acute coronary syndrome patients: a multicenter study. Clin Chem. 2001; 47:464-70.
  • 28
    Gidenne S, Ceppa F, Fontan E, Perrier F, Burnat P. Analytical performance of the Albumin Cobalt Binding (ACB) test on the Cobas MIRA Plus analyzer. Clin Chem Lab Med. 2004; 42:455-61.
  • 29
    Roy D, Quiles J, Sharma R, Sinha M, Avanzas P, Gaze D, et al. Ischemia-modified albumin concentrations in patients with peripheral vascular disease and exercise-induced skeletal muscle ischemia. Clin Chem. 2004; 50:1656-60.
  • 30
    Kiyici A, Mehmetoğlu I, Karaoğlan H, Atalay H, Solak Y, Türk S. Ischemia-modified albumin levels in patients with end-stage renal disease patients on hemodialysis: does albumin analysis method affect albumin-adjusted ischemia-modified albumin levels? J Clin Lab Anal. 2010; 24:273-7.
  • 31
    Abboud H, Labreuche J, Meseguer E, Lavallee PC, Simon O, Olivot JM, et al. Ischemia-modified albumin in acute stroke. Cerebrovasc Dis. 2007; 23:216-20.
  • 32
    Apple FS, Quist HE, Otto AP, Mathews WE, Murakami MM. Release characteristics of cardiac biomarkers and ischemia-modified albumin as measured by the albumin cobalt-binding test after a marathon race. Clin Chem. 2002; 48:1097-100.
  • 33
    Falkensammer J, Stojakovic T, Huber K, Hammerer-Lercher A, Gruber I, Scharnagl H, et al. Serum levels of ischemia-modified albumin in healthy volunteers after exercise-induced calf-muscle ischemia. Clin Chem Lab Med. 2007; 45:535-40.
  • 34
    Hoekstra LT, Ruys AT, Milstein DM, van Samkar G, van Berge Henegouwen MI, Heger M, et al. Effects of prolonged pneumoperitoneum on hepatic perfusion during laparoscopy. Ann Surg. 2013; 257:302-7.
  • 35
    Ho HS, Saunders CJ, Gunther RA, Wolfe BM. Effector of hemodynamics during laparoscopy: CO2 absorption or intra-abdominal pressure? J Surg Res. 1995; 59:497-503.
  • 36
    Westerband A, Van De Water J, Amzallag M, Lebowitz PW, Nwasokwa ON, Chardavoyne R, et al. Cardiovascular changes during laparoscopic cholecystectomy. Surg Gynecol Obstet. 1992; 175:535-8.
  • 37
    Johannsen G, Andersen M, Juhl B. The effect of general anaesthesia on the haemodynamic events during laparoscopy with CO2-insufflation. Acta Anaesthesiol Scand. 1989; 33:132-6.
  • 38
    Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 1995; 39:949-55.
  • 39
    Lestar M, Gunnarsson L, Lagerstrand L, Wiklund P, Odeberg-Wernerman S. Hemodynamic perturbations during robot-assisted laparoscopic radical prostatectomy in 45° Trendelenburg position. Anesth Analg. 2011; 113:1069-75.
  • 40
    Windberger UB, Auer R, Keplinger F, Längle F, Heinze G, Schindl M, et al. The role of intra-abdominal pressure on splanchnic and pulmonary hemodynamic and metabolic changes during carbon dioxide pneumoperitoneum. Gastrointest Endosc. 1999; 49:84-91.
  • 41
    Gianotti L, Nespoli L, Rocchetti S, Vignali A, Nespoli A, Braga M. Gut oxygenation and oxidative damage during and after laparoscopic and open left-sided colon resection: a prospective, randomized, controlled clinical trial. Surg Endosc. 2011; 25:1835-43.

Publication Dates

  • Publication in this collection
    Jan-Feb 2016

History

  • Received
    30 Dec 2014
  • Accepted
    12 Aug 2015
Sociedade Brasileira de Urologia Rua Bambina, 153, 22251-050 Rio de Janeiro RJ Brazil, Tel. +55 21 2539-6787, Fax: +55 21 2246-4088 - Rio de Janeiro - RJ - Brazil
E-mail: brazjurol@brazjurol.com.br