Acessibilidade / Reportar erro

Biocompatibility of orthodontic adhesives in rat subcutaneous tissue

Abstract

ABSTRACT OBJECTIVE: The objective of the present study was to verify the hypothesis that no difference in biocompatibility exists between different orthodontic adhesives. MATERIAL AND METHODS: Thirty male Wistar rats were used in this study and divided into five groups (n=6): Group 1 (control, distilled water), Group 2 (Concise), Group 3 (Xeno III), Group 4 (Transbond XT), and Group 5 (Transbond plus Self-Etching Primer). Two cavities were performed in the subcutaneous dorsum of each animal to place a polyvinyl sponge soaked with 2 drops of the respective adhesive in each surgical loci. Two animals of each group were sacrificed after 7, 15, and 30 days, and their tissues were analyzed by using an optical microscope. RESULTS: At day 7, Groups 3 (Transbond XT) and 4 (Xeno III) showed intense mono- and polymorphonuclear inflammatory infiltrate with no differences between them, whereas Groups 1 (control) and 2 (Concise) showed moderate mononuclear inflammatory infiltrate. At day 15, severe inflammation was observed in Group 3 (Transbond XT) compared to other groups. At day 30, the same group showed a more expressive mononuclear inflammatory infiltrate compared to other groups. CONCLUSION: Among the orthodontic adhesive analyzed, it may be concluded that Transbond XT exhibited the worst biocompatibility. However, one cannot interpret the specificity of the data generated in vivo animal models as a human response.

Orthodontic adhesives; Biocompatibility testing; Inflammation


ORIGINAL ARTICLES

Biocompatibility of orthodontic adhesives in rat subcutaneous tissue

Rogério Lacerda dos SantosI; Matheus Melo PithonI; Alline Birra Nolasco FernandesII; Márcia Grillo CabralIII; Antônio Carlos de Oliveira RuellasIV

IDDS, MS, Specialist in Orthodontics, PhD student in Orthodontics, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil

IIUndergraduate Dental Student, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil, Brazil

IIIDDS, MS, PhD, Adjunct Professor of Oral Pathology, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil, Brazil

IVDDS, MS, PhD, Adjunct Professor, Federal University, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil, Brazil

Corresponding address Corresponding address: Rogério Lacerda dos Santos Rua Ipatinga, 170 - Planalto Divinópolis - MG - Brazil 35501-191 e-mail: lacerdaorto@hotmail.com or lacerdaorto@bol.com.br

ABSTRACT

OBJECTIVE: The objective of the present study was to verify the hypothesis that no difference in biocompatibility exists between different orthodontic adhesives.

MATERIAL AND METHODS: Thirty male Wistar rats were used in this study and divided into five groups (n=6): Group 1 (control, distilled water), Group 2 (Concise), Group 3 (Xeno III), Group 4 (Transbond XT), and Group 5 (Transbond plus Self-Etching Primer). Two cavities were performed in the subcutaneous dorsum of each animal to place a polyvinyl sponge soaked with 2 drops of the respective adhesive in each surgical loci. Two animals of each group were sacrificed after 7, 15, and 30 days, and their tissues were analyzed by using an optical microscope.

RESULTS: At day 7, Groups 3 (Transbond XT) and 4 (Xeno III) showed intense mono- and polymorphonuclear inflammatory infiltrate with no differences between them, whereas Groups 1 (control) and 2 (Concise) showed moderate mononuclear inflammatory infiltrate. At day 15, severe inflammation was observed in Group 3 (Transbond XT) compared to other groups. At day 30, the same group showed a more expressive mononuclear inflammatory infiltrate compared to other groups.

CONCLUSION: Among the orthodontic adhesive analyzed, it may be concluded that Transbond XT exhibited the worst biocompatibility. However, one cannot interpret the specificity of the data generated in vivo animal models as a human response.

Key words: Orthodontic adhesives. Biocompatibility testing. Inflammation.

INTRODUCTION

Orthodontic adhesives are used to provide effective union between composite and dental structure. However, the most common substances present in adhesive systems show a well defined cytotoxic effect1,6,15. These adhesives are used in moist media and often on contaminated surfaces without compromising their adhesion, but different compounds can be released during the aqueous phase11, such as non-polymerized free monomers from resin materials5. Some authors have demonstrated that these free monomers caused apoptosis in cell culture16,26. In vivo studies17,19 show that non-polymerized resin compounds released from dental adhesives cause a pulp inflammatory response, which is visible and chronic8. Recent studies4,5 have shown presence of macrophages together with resin compounds following restorative procedure5, in which a persistent and chronic inflammatory response was observed over a period of 300 days. In general, the adhesives used in orthodontics are chosen based on the research on mechanical assays and effectiveness in sealing the interface between tooth and orthodontic accessory. However, many research studies on the biocompatibility of dental materials are currently being performed5,7,8,15,20. Taken together, all these findings are in accordance with the idea that the close proximity of orthodontic accessories to gingival and oral tissues makes this issue very important when choosing these adhesives. Therefore, the aim of the present work was test the hypothesis that there is no difference in biocompatibility between the adhesives used for attaching orthodontic accessories.

MATERIAL AND METHODS

This study used 30 male adult Wistar rats weighing 250-350 g, which were divided into five groups of 6 animals each: Group 1 (control, distilled water), Group 2 (Concise, 3M Unitek Orthodontic Products, Monrovia, CA, USA), Group 3 (Xeno III, Dentsply/DeTrey, Konstanz, Baden-Württemberg, Germany), Group 4 (Transbond XT, 3M Unitek Orthodontic Products) and Group 5 (Transbond Self-Etching Primer, 3M Unitek Orthodontic Products) (Figure 1). The rats were anesthetized with intraperitoneal injection of sodium thiopental (50 mg/kg) (THIO, Cristália, Itapira, SP, Brazil), and the dorsal region (4x4 cm) of each animal was shaved. Asepsis of the operatory area was done with 4% chlorhexidine digluconate (School of Pharmacy, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil). Two midline incisions of approximately 8 mm in length were made equidistantly from the tail base to the head of the animal with a #5 scalpel blade mounted onto a scalpel handle. The subcutaneous tissue was laterally separated using a pair of blunt-ended scissors, resulting in two approximately 18-mm-deep surgical loci each. All animals received two PVA sponge implants (4.0 mm long x 2.0 mm diameter). The implants were previously kept in 70% alcohol for 120 min, rinsed with sterile distilled water, autoclaved and then soaked with 2 drops of the respective adhesives. The adhesives in the sponges were photoactivated with a LED source unit (Radii, SDI, Baywater, Victoria, Australia) according to the application time recommended by the manufacturer. The light intensity of the curing unit (1000 mW/cm2) was checked immediately before each polymerization using a radiometer (Model 100, Demetron Research Corporation, Danbury, CT, USA). The surgical loci were sutured with 4.0 suture (Ethicon, Johnson & Johnson, São José dos Campos, São Paulo, Brazil) and then the animals received an injection of sodium dipyrone (0.3 mL/100 g Novalgina®; Sanofi-Aventis Farmacêutica LTDA, Suzano, SP, Brazil).


The rats were kept in cages and fed balanced food and water. After 7, 15, and 30 days, the animals were anesthetized and submitted to excisional biopsy at the implantation area so that enough surrounding normal tissue could be collected. Each group consisted of 6 rats with two implants, thus resulting in 12 samples per group (Table 1). Next, the animals were sacrificed by cervical dislocation.

After being fixed in 4% formaldehyde (Milony solution) for 24 h, the samples were inserted into paraffin and then 6-µm-thick histological sections were cut and stained with hematoxylin and eosin. The inflammatory responses induced by the adhesives were examined with a light microscope and classified as mild, moderate, and severe17,19. The biocompatibility of the materials was determined according to the ISO 10993-313 standard.

DISCUSSION

The quality and specificity of the data generated by in vivo models is questioned and criticized in literature30, depends of use of a biological system that reproduces as close as possible the metabolic behavior of the target organ for the toxic effect of xenobiotics and of choice of appropriate parameters to evaluate toxic effects. Evaluating the biocompatibility of orthodontic adhesives by means of subcutaneous implants in rats is of great value as the tissue response in rats is similar to that expected when the same material is applied to the gingival tissue surrounding the area to receive orthodontic accessories.

Several studies have assessed the biocompatibility of dental materials5,7,8,15,20. However, methodological divergence exists. In the present study, polyvinyl sponges saturated with the respective adhesives were inserted into rats subcutaneous tissue and then light cured17 in an attempt to simulate actual clinical procedures.

Costa, et al.6 (1999) have used polyvinyl sponges saturated with adhesives that had not been photoactivated after surgical implantation, allowing the adhesive and their monomers to be in close contact with the subcutaneous connective tissue. Therefore, not only a cytotoxic effect of the dental adhesive was observed but also a persistent inflammatory reaction resulting from the resin compounds. According to the authors, these materials do not seem to be suitable for direct application to connective tissue.

Studies15,21,29 have demonstrated the cytotoxicity of the compounds of adhesive systems, which can be explained by the different compositions, mechanisms, and application procedures as well as by methodological variations1. However, it is clear that the choice for a given adhesive system should be based on its biocompatibility.

The most often studied method for in vivo analysis of biocompatibility relies on inflammation17. Analyzing and rating the inflammation phenomena in different experimental groups makes it possible to establish the best biocompatibility by placing the material in contact with vascularized tissues and observing the different reactions. It is also important to use an innocuous substance in the control group in order to facilitate data interpretation17.

The inflammatory response begins with a more intense reaction to both surgical procedures and implanted foreign body, and because such a reaction is not specific, the first post-surgical hours are not taken into account. After 7 days, a more organized inflammatory reaction was expected due to the adhesive rather than the surgical procedure.

The decrease in the inflammatory intensity relies on the control of the host defense system, which organizes itself to limit the aggressive action from the compounds existing in the adhesives and to localize the inflammatory reaction. It was possible to differentiate the inflammation intensity between the experimental groups, mainly regarding the higher level of cytotoxic from Xeno III and Transbond XT after 7 days.

Methacrylate monomers such as TEGDMA, Bis-GMA, UDMA, and HEMA, which are largely used in the composition of dentinal adhesives, can cause cell lesion10,12. TEGDMA, Bis-GMA, UDMA are hydrophobic monomers that are often associated with HEMA. Diffusion of these monomers can be facilitated because HEMA increases the hydrophilic characteristic of the material. Under such conditions, the hydrophobic monomers can reach the cells and damage them10,12,23.

With respect to Xeno III, the presence of HEMA in association with ethanol seems to cause more cell damage. The ethanol in relation with the oral mucosa showed increased mucosal permeability13,24 and penetration of potential carcinogens across the mucosal permeability barrier13. It has been reported that topical application of ethanol on the oral mucosa affects epithelial cell homeostasis2 and alters mucosal structure18.

In the present study, a mild reaction was observed in the control group whose sponges were saturated with distilled water, whereas a moderate to severe reaction was found in all experimental groups. After 15 and 30 days, the inflammatory reaction was visible, thus allowing the biocompatibility of the materials to be rated in ascending order. In general, small necrotic areas with edema surrounded by cell proliferation, consequent deposition of collagen fibers, chronic inflammation, and decreased number of blood vessels were observed. The presence of multinuclear giant cells suggests the formation of granulomas due to the presence of sponge and/or adhesive material. Therefore, these events are described as a favorable tissue response regarding the biocompatibility of the material.

At the end of the 30-day period, it was possible to observe that all adhesive systems showed good biocompatibility, although Transbond XT was found to be more aggressive compared to other groups as formation of abscess occurred at the implant region. Based on this finding, one can conclude that Transbond XT is the least biocompatible adhesive.

According to in the literature, HEMA is an important toxic component released by most adhesive systems since several in vitro studies have demonstrated a defined cytotoxicity of HEMA to the culture of cells3,25. Methacrylate monomers, such as HEMA, are incorporated in the lipid bilayers of cell membranes which are solubilized by the unreacted monomers10. This mechanism of action of uncured leached monomers on the cell membrane may be regarded as responsible for the high cytotoxicity of Transbond (Transbond XT, 3M Unitek) observed in the present investigation.

Traditionally, persulfate molecules have been used as initiators in redox water-based polymerization systems to decrease the amount of residual monomers after setting14. The high cytotoxicity of adhesive systems is probably caused by leachable resin components, such as TEGDMA, Bis-GMA and HEMA, which has frequently been added to their chemical composition9.

However, it may be speculated that some minor adhesive components released into the connective tissue, such as HEMA, which presents low molecular weight, might be removed by local lymphatic drainage. This hypothesis should explain why the inflammatory reaction decreased with time and the connective tissue healing occurred for all experimental materials at 30 days following the implantation.

Sohoel, et al.22 (1994), after testing adhesives in pigs, have suggested that orthodontic adhesives can be potentially allergenic for human being, particularly the "no-mix" ones, and lead to adverse reactions in both patients and practitioners. Such cytotoxicity can last two years after polymerisation27.

Thompson, et al.28 (1982) have concluded that even adequately mixed and set, the orthodontic adhesives showed great amounts of material that not had been cured (up to 14% of the material), thus resulting in potential toxicity. Therefore, in addition to adequately preparing and applying these products, the clinician should be careful not to expose skin, mucosa, and gingival to these materials for long periods of time, particularly the subgingival and interproximal areas.

CONCLUSIONS

It is possible (and safer) to evaluate inflammatory and healing phenomena to characterize, and rate the experimental groups by comparing them to a control group. This allows us to state that Xeno III, Transbond SEP, and Concise adhesives had the best biocompatibility, since formation of chronic inflammation with peripheral healing phenomena and multinuclear giant cells around the samples were observed. However, one cannot interpret the specificity of the data generated in vivo animal models as a human response. The hypothesis was rejected and one can state that, among the adhesives studied, Transbond XT was found to have the worst biocompatibility.

Received: February 2, 2009

Modification: September 5, 2009

Accepted: February 16, 2010

  • 1- al-Dawood A, Wennberg A. Biocompatibility of dentin bonding agents. Endod Dent Traumatol. 1993;9(1):1-7.
  • 2- Axford SE, Ogden GR, Stewart AM, Saleh HA, Ross PE, Hopwood D. Fluid phase endocytosis within buccal mucosal cells of alcohol misusers. Oral Oncol. 1999;35(1):86-92.
  • 3- Bouillaguet S, Wataha JC, Hanks CT, Ciucchi B, Holz J. In vitro cytotoxicity and dentin permeability of HEMA. J Endod. 1996;22(5):244-8.
  • 4- Costa CA, Giro EM, Nascimento AB, Teixeira HM, Hebling J. Short-term evaluation of the pulpo-dentin complex response to a resin-modified glass-ionomer cement and a bonding agent applied in deep cavities. Dent Mater. 2003;19(8):739-46.
  • 5- Costa CA, Hebling J, Hanks CT. Current status of pulp capping with dentin adhesive systems: a review. Dent Mater. 2000;16(3):188-97.
  • 6- Costa CA, Teixeira HM, Nascimento AB, Hebling J. Biocompatibility of an adhesive system and 2-hydroxyethylmethacrylate. ASDC J Dent Child. 1999;66(5):337-42.
  • 7- Cox CF, Kim KM, Stevenson RG 3rd, Hafez AA. Histological evaluation of a self-priming etchant adhesive system. Compend Contin Educ Dent. 2003;24(8):17-20.
  • 8- Souza Costa CA, Nascimento AB, Teixeira HM. Response of human pulps following acid conditioning and application of a bonding agent in deep cavities. Dent Mater. 2002;18(7):543-51.
  • 9- Souza Costa CA, Hebling J, Garcia-Godoy F, Hanks CT. In vitro cytotoxicity of five glass-ionomer cements. Biomaterials. 2003;24(21):3853-8.
  • 10- Fujisawa S, Kadoma Y, Komoda Y. 1H and 13C NMR studies of the interaction of eugenol, phenol, and triethyleneglycol dimethacrylate with phospholipid liposomes as a model system for odontoblast membranes. J Dent Res. 1988;67(11):1438-41.
  • 11- Geurtsen W, Spahl W, Muller K, Leyhausen G. Aqueous extracts from dentin adhesives contain cytotoxic chemicals. J Biomed Mater Res. 1999;48(16):772-7.
  • 12- Hanks CT, Wataha JC, Sun Z. In vitro models of biocompatibility: a review. Dent Mater. 1996;12(3):186-93.
  • 13- Howie NM, Trigkas TK, Cruchley AT, Wertz PW, Squier CA, Williams DM. Short-term exposure to alcohol increases the permeability of human oral mucosa. Oral Dis. 2001;7(6):349-54.
  • 14- Kakaboura A, Eliades G, Palaghias G. An FTIR study on the setting mechanism of resin-modified glass ionomer restoratives. Dent Mater. 1996;12(3):173-8.
  • 15- Kostoryz EL, Eick JD, Glaros AG, Judy BM, Welshons WV, Burmaster S, et al. Biocompatibility of hydroxylated metabolites of BISGMA and BFDGE. J Dent Res. 2003;82(5):367-71.
  • 16- Lefeuvre M, Amjaad W, Goldberg M, Stanislawski L. TEGDMA induces mitochondrial damage and oxidative stress in human gingival fibroblasts. Biomaterials. 2005;26(25):5130-7.
  • 17- Machado NP, Moysés MR, Pereira AAC, Pereira LJ, Ribeiro JCR, Dias SC. Study of dentinal adhesives compatibility using histological analysis. Braz J Oral Sci. 2007;6(20):1289-94.
  • 18- Maier H, Tisch M. Epidemiology of laryngeal cancer: results of the Heidelberg case-control study. Acta Otolaryngol Suppl. 1997;527:160-4.
  • 19- Moyses MR, Lopes WL, Pereira AAC, Ribeiro JCR, Dias SC, Pereira LJ. Biocompatibility of the Prime & Bond 2.1, Prime & Bond NT and Scothbond MP Primer adhesive systems. Braz J Oral Sci. 2006;5(18):1079-84.
  • 20- Mussel RL, Sa Silva E, Costa AM, Mandarim-De-Lacerda CA. Mast cells in tissue response to dentistry materials: an adhesive resin, a calcium hydroxide and a glass ionomer cement. J Cell Mol Med. 2003;7(2):171-8.
  • 21- Nagem-Filho H, Monteiro CR, Nagem HD, Lage-Marques JL. Effect of dental adhesives on the exudative phase of the inflammatory process in subcutaneous tissue of rats. Pesqui Odontol Bras. 2003;17(2):109-12.
  • 22- Sohoel H, Gjerdet NR, Hensten-Pettersen A, Ruyter IE. Allergenic potential of two orthodontic bonding materials. Scand J Dent Res. 1994;102(2):126-9.
  • 23- Souza PP, Aranha AM, Hebling J, Giro EM, Costa CA. In vitro cytotoxicity and in vivo biocompatibility of contemporary resin-modified glass-ionomer cements. Dent Mater. 2006;22(9):838-44.
  • 24- Squier CA, Cox P, Hall BK. Enhanced penetration of nitrosonornicotine across oral mucosa in the presence of ethanol. J Oral Pathol. 1986;15(5):276-9.
  • 25- Stanislawski L, Daniau X, Lauti A, Goldberg M. Factors responsible for pulp cell cytotoxicity induced by resin-modified glass ionomer cements. J Biomed Mater Res. 1999;48(3):277-88.
  • 26- Stanislawski L, Lefeuvre M, Bourd K, Soheili-Majd E, Goldberg M, Perianin A. TEGDMA-induced toxicity in human fibroblasts is associated with early and drastic glutathione depletion with subsequent production of oxygen reactive species. J Biomed Mater Res A. 2003;66(3):476-82.
  • 27- Tell RT, Sydiskis RJ, Isaacs RD, Davidson WM. Long-term cytotoxicity of orthodontic direct-bonding adhesives. Am J Orthod Dentofacial Orthop. 1988;93(5):419-22.
  • 28- Thompson LR, Miller EG, Bowles WH. Leaching of unpolymerized materials from orthodontic bonding resin. J Dent Res. 1982;61(8):989-92.
  • 29- Vajrabhaya LO, Pasasuk A, Harnirattisai C. Cytotoxicity evaluation of single component dentin bonding agents. Oper Dent. 2003;28(4):440-4.
  • 30- Vande Vannet BM, Hanssens JL. Cytotoxicity of two bonding adhesives assessed by three-dimensional cell culture. Angle Orthod. 2007;77(4):716-22.
  • Corresponding address:
    Rogério Lacerda dos Santos
    Rua Ipatinga, 170 - Planalto Divinópolis - MG - Brazil
    35501-191
    e-mail:
  • Publication Dates

    • Publication in this collection
      05 Nov 2010
    • Date of issue
      Oct 2010

    History

    • Reviewed
      05 Sept 2009
    • Received
      02 Feb 2009
    • Accepted
      16 Feb 2010
    Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil
    E-mail: jaos@usp.br