Acessibilidade / Reportar erro

A castor oil-containing dental luting agent: effects of cyclic loading and storage time on flexural strength

Abstract

Favorable results in the use of castor oil polyurethane (COP) as pulp capping, membrane material, sealer, mouthwash and in bone repair, associated with the fact that Ricinus communis is not derived from petroleum and it is abundant in Brazil, encourage researches in the development of luting agents.

Objectives

This study compared the flexural strength (FS) of a castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate (COP10) with RelyX ARC (RX) after mechanical cycling (MC) and distilled water storage.

Material and Methods

Sixty-four specimens (25x2x2 mm) were fabricated and divided into two groups, COP10 and RX (control). Each group was divided into 4 subgroups (n=8) according to the storage time, 24 hours (24 h) or 60 days (60 d), and the performance (MC+FS) or not (only FS) of the mechanical cycling test. The FS (10 kN; 0.5 mm/min) and MC tests (10,000 cycles, 5 Hz, 0.5 mm/min) were carried out using an MTS-810 machine. The data were analyzed using ANOVA (α=0.05).

Results

The obtained FS (MPa) values were: COP10 24h- 19.04±2.41; COP10 60d- 17.92±3.54; RX 24h- 75.19±3.43; RX 60d- 88.77±6.89. All the RX specimens submitted to MC fractured, while the values for COP10 after MC were as follows: COP10 24h- 17.90±1.87 and COP10 60d- 18.60±1.60.

Conclusions

A castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate is resistant to mechanical cycling without decreases in flexural strength. However, mean COP10 showed only about 25% of the RelyX ARC mean flexural strength.

Biocompatible materials; Polyurethanes; Dental cements; Material resistance; Aging


INTRODUCTION

Polymers are biocompatible materials of natural or synthetic origin that can be prepared by different methods3434 - Yaszemski MJ, Payne RG, Hayes WC, Langer R, Mikos AG. Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone. Biomaterials. 1996;17:175-85.. In dentistry, various polymers are used, such as silicone, methyl methacrylate and polyurethane. Currently, vegetable-polyurethane, which combines the versatility of polymer formulation while addressing the global concern towards producing new biomaterials from sustainable resources, has become one of the most studied biomaterials3- Bao H, Zhang ZP, Ying S. Effect of ionic group on the behaviour of polyurethaneurea emulsion. Polymer. 1996;37:2751-4.. The use of vegetable-polyurethane derived from castor oil (COP) in the health science fields has been studied, and COP has shown favorable results in tests for biocompatibility2222 - Monteiro AS, Macedo LG, Macedo NL, Balducci I. Polyurethane and PTFE membranes for guided bone regeneration: histopathological and ultrastructural evaluation. Med Oral Patol Oral Cir Bucal. 2010;15:401-6.. Castor oil is a new material that is globally available, and it has received much attention in recent years because of its availability on a large commercial scale2323 - Nayak P, Mishra DK, Sahoo KC, Pati NC, Jena PK, Lenka S, et al. Polymers from renewable resources. XIII. Interpenetrating polymer networks derived from castor oil-hexamethylene diisocyanate and polymethacrylamide. J Appl Polymer Sci. 2001;80:1349-53..

The COP is a biocompatible, antimicrobial, osteointegrable and absorbable, osteoconductive and osteoinductive1313 - Ferreira CM, Silva Rosa OP, Torres SA, Ferreira FB, Bernardinelli N. Activity of endodontic antibacterial agents against selected anaerobic bacteria. Braz Dent J. 2002;13:118-22.. In dentistry, the use of this polymer has been studied in direct pulp capping5- Camargo SE, Rode SM, Prado RF, Carvalho YR, Camargo CH. Subcutaneous tissue reaction to castor oil bean and calcium hydroxide in rats. J Appl Oral Sci. 2010;18:273-8., as a membrane material2222 - Monteiro AS, Macedo LG, Macedo NL, Balducci I. Polyurethane and PTFE membranes for guided bone regeneration: histopathological and ultrastructural evaluation. Med Oral Patol Oral Cir Bucal. 2010;15:401-6., as a sealer3131 - Rosa PC, Mancini MN, Camargo SE, Garrido AD, Camargo CH, Rode SM. Dimensional alterations and solubility of new endodontic sealers. Braz Dent J. 2010;21:301-4., as a mouthwash2828 - Pinelli LA, Montandon AA, Corbi SC, Moraes TA, Fais LM. Ricinus communis treatment of denture stomatitis in institutionalised elderly. J Oral Rehabil. 2013;40:375-80., as bone prosthesis and in alveolar healing7- Carvalho TL, Araújo CA, Teófilo JM, Brentegani LG. Histologic and histometric evaluation of rat alveolar wound healing around polyurethane resin implants. Int J Oral Maxillofac Surg. 1997;26:149-52. and bone reconstruction2020 - Leite FR, Ramalho LT. Bone regeneration after demineralized bone matrix and castor oil (Ricinus communis) polyurethane implantation. J Appl Oral Sci. 2008;16:122-6.. In clinical research focusing on human dental alveoli, Jowett, et al.1919 - Jowett AK, Ferguson MW, Combe EC. In vitro biocompatibility testing: a new organ culture model. J Dent. 1988;16:55-65. (1988) showed that this polyurethane has good biocompatibility for use both in soft and hard tissue, has osteoinductive properties, and can be bactericidal and fungicidal when combined with calcium carbonate.

The versatility of the polyurethane derived from castor oil as well as the aforementioned positive aspects support the study of COP as a dental luting agent. Although a wide range of dental luting agents is commercially available, the selection of a luting agent to be used for a given restoration should not be an arbitrary choice. It must be based on a basic knowledge of the materials available, the type of restoration to be placed, and the requirements defined by the patient1717 - Hill EE. Dental cements for definitive luting: a review and practical clinical considerations. Dent Clin North Am. 2007;51:643-58. based on the functional and biological needs2- Attar N, Tam LE, McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent. 2003;89:127-34. of a particular clinical situation, including handling characteristics such as working time, setting time, consistency and ease of removal of excess material3333 - Shen C. Dental cements. In: Anusavice KJ, ed. Philips’ science of dental materials. St. Louis: Elsevier; 2003. p.471-85.. As such, no single dental luting agent is considered ideal, and new products should be studied. It is important to characterize the mechanical, physical and biological properties of COP. When compared with zinc phosphate cement, the COP, with the addition of calcium carbonate, presented better diametral tensile strength values and was associated with better film thickness6- Carmello JC, Fais LM, Ribeiro LN, Claro Neto S, Guaglianoni DG, Pinelli LA. Diametral tensile strength and film thickness of an experimental dental luting agent derived from castor oil. J Appl Oral Sci. 2012;20:16-20.. The addition of calcium carbonate is responsible for conferring radiopacity to COP2929 - Pinelli LA, Fais LM, Ricci WA, Reis JM. In vitro comparisons of casting retention on implant abutments among commercially available and experimental castor oil-containing dental luting agents. J Prosthet Dent. 2013;109:319-24.. Moreover, this filler provides the release of calcium ions, facilitating ion exchange at the bone/resin matrix interface1515 - Frazilio FO, Rossi R, Negrini Neto J, Facco GG, Ovando M, Fialho M. Use of castor oil polyurethane in an alternative technique for medial patella surgical correction in dogs. Acta Cir Bras. 2006;21:74-9., which may be beneficial in subgingival restoration margins. The COP dental luting agents are deemed strong enough to resist masticatory stresses and provide retention similar to that of zinc phosphate cement, a permanent cementation material2929 - Pinelli LA, Fais LM, Ricci WA, Reis JM. In vitro comparisons of casting retention on implant abutments among commercially available and experimental castor oil-containing dental luting agents. J Prosthet Dent. 2013;109:319-24..

In the oral cavity, the chewing forces applied to restorative materials result in cycles of mechanical impulses that lead to material fatigue and, consequently, fracture. These impulses can be simulated in the laboratory by performing mechanical cycling, which approaches the physiological conditions generated by the chewing cycle2424 - Nikaido T, Kunzelmann KH, Chen H, Ogata M, Harada N, Yamaguchi S, et al. Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin. Dent Mater. 2002;18:269-75.. Fixed partial dentures are more likely to be subjected to bending forces than to other types of stress1010 - Duymus ZY, Yanikoğlu ND, Alkurt M. Evaluation of the flexural strength of dual-cure composite resin cements. J Biomed Mater Res B Appl Biomater. 2013;101:878-81.,2525 - Oilo G, Espevik S. Stress/strain behavior of some dental luting cements. Acta Odontol Scand. 1978;36:45-9.,2626 - Pace LL, Hummel SK, Marker VA, Bolouri A. Comparison of the flexural strength of five adhesive resin cements. J Prosthodont. 2007;16:18-24.. As such, the flexural properties of the restorative material are more important than their tensile, shear and compressive strengths. Moreover, the flexural strength test is considered the most appropriate for simulating the clinical situation of material fatigue4- Blackman R, Barghi N, Duke E. Influence of ceramic thickness on the polymerization of light-cured resin cement. J Prosthet Dent. 1990;63:295-300.,3232 - Saskalauskaite E, Tam LE, McComb D. Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont. 2008;17:262-8. because the concentration of masticatory forces causes flaws and microcracks in the dental luting agent prior to the fracture or displacement of the restoration material1111 - Fan P, Nicholls JI, Kois JC. Load fatigue of five restoration modalities in structurally compromised premolars. Int J Prosthodont. 1995;8:213-20.. The mechanical properties of resinous materials are directly related to the quantity and type of inorganic particles8- Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76:1405-11., degree of cure and percentage of silane-treated filler1212 - Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42:465-72., with the flexural strength being directly proportional to amount of filler particles3030 - Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent. 2003;28:535-42.. Most current in vitro studies include cycling testing with dynamic loads in order to assess the influence of stress on the material1616 - Freeman MA, Nicholls JI, Kydd WL, Harrington GW. Leakage associated with load fatigue-induced preliminary failure of full crowns placed over three different post and core systems. J Endod. 1998;24:26-32.,2121 - Mannocci F, Ferrari M, Watson TF. Microleakage of endodontically treated teeth restored with fiber posts and composite cores after cyclic loading: a confocal microscopic study. J Prosthet Dent. 2001;85:284-91..

The aim of this study was to assess the behavior of COP under masticatory stress simulated by mechanical cycling. The flexural strength of COP with a weight percentage of 10% (wt%) of calcium carbonate was analyzed with and without the performance of the mechanical cycling test as well as with storage in distilled water. The results were compared with the results for RelyX ARC. The null hypothesis was that there is no difference between the flexural strength of COP10 and that of RelyX ARC.

MATERIAL AND METHODS

The procedure of the study is summarized in Figure 1. For the COP10 group, 32 specimens were fabricated with the castor oil-containing dental luting agent (Castor Oil Polyurethane - COP, Poliquil Araraquara, Chemical Polymers Ltd, Araraquara, SP, Brazil) with a weight percentage of 10% (wt%) of calcium carbonate (CaCO3). For the control group, named RX, 32 specimens were fabricated with the resin cement RelyX ARC (3M ESPE, Sumaré, SP, Brazil). Each group was randomly divided into 4 subgroups (n=8) according to the storage time in distilled water, 24 hours (24 h) or 60 days (60 d), and the performance or not of the mechanical cycling (MC) test.

Figure 1
Flow chart of the study

The COP was provided in a sachet containing polyol, prepolymer and calcium carbonate6- Carmello JC, Fais LM, Ribeiro LN, Claro Neto S, Guaglianoni DG, Pinelli LA. Diametral tensile strength and film thickness of an experimental dental luting agent derived from castor oil. J Appl Oral Sci. 2012;20:16-20.. This polyurethane has the following highly reactive groups in the ricinoleic acid structure: a carbonyl group on the first carbon, a double bond (or unsaturation) on the ninth carbon and a hydroxyl group on the twelfth carbon. This combination of a hydroxyl group and unsaturation occurs exclusively in the castor oil molecule1414 - Ferreira P, Pereira R, Coelho JF, Silva AF, Gil MH. Modification of the biopolymer castor oil with free isocyanate groups to be applied as bioadhesive. Int J Biol Macrom. 2007;40:144-52.. Prepolymer was synthesized from methylene diphenyl diisocyanate (MDI) and was prepolymerized with the polyol while preserving 20% of free isocyanate. When these two components were mixed, the moisture-curing kinetics was determined by the polymerization reaction between the isocyanate and hydroxyl groups. The stoichiometric ratio between the polyol and the prepolymer was equal to 1:0.66.

For the COP10 specimens, the material was manually mixed in the sachet for 2 minutes. It was then mixed with a spatula on a Teflon plate for an additional 2 minutes to obtain the final consistency6- Carmello JC, Fais LM, Ribeiro LN, Claro Neto S, Guaglianoni DG, Pinelli LA. Diametral tensile strength and film thickness of an experimental dental luting agent derived from castor oil. J Appl Oral Sci. 2012;20:16-20.. The material was inserted into a Teflon matrix (2x2x25 mm) positioned between two Teflon plates. This apparatus was placed in a mechanical press under constant load and stored in saturated water vapor in a container lined with wet paper at 37°C for one hour9- Council adopts American Dental Association. Specification No. 8 (dental zinc phosphate cement) and 11 (agar impression material). Council on Dental Materials and Devices. J Am Dent Assoc. 1967;74:1565-73..

For the RX group, the cement was manipulated according to the instructions of the manufacturer, dispensed on the Teflon matrix (2x2x25 mm) and cured with light at three points along its length on both sides for 40 seconds each1010 - Duymus ZY, Yanikoğlu ND, Alkurt M. Evaluation of the flexural strength of dual-cure composite resin cements. J Biomed Mater Res B Appl Biomater. 2013;101:878-81.. The matrix was placed in a mechanical press under constant load and stored in saturated water vapor in a container lined with wet paper at 37°C for one hour9- Council adopts American Dental Association. Specification No. 8 (dental zinc phosphate cement) and 11 (agar impression material). Council on Dental Materials and Devices. J Am Dent Assoc. 1967;74:1565-73..

After the initial storage period of 1 hour, all the samples were removed from the matrix and polished with 200 grit silicon carbide sandpaper (3M ESPE). Then, they were measured at three points using a digital caliper (500-144B, Mitutoyo Sul America Ltd, Suzano, SP, Brazil) to verify the width and thickness. A variance of ±0.2 mm was accepted. The samples were immersed in distilled water at 37°C for the specified periods according to the subgroups.

All samples were subjected to 3-point bending test, which was conducted in a universal testing machine (MTS 810, Material Test System, Eden Prairie, MN) equipped with the Test Work 4 software, at a crosshead of 0.5 mm/min18 and with a 10 kN load cell. The FS values were calculated in MPa according to the following formula: σ=3PI/2bd2 (σ=flexural strength, P=maximum load at fracture point, I=distance between the supports, b=width of the samples, d=thickness of the samples). The MC procedure was carried out under conditions equivalent to those used for the FS test. Samples were submitted to 10,000 cycles at a frequency of 5 Hz and a cross-head displacement of 0.5 mm. The initial load was 60% of the mean FS value previously obtained. After completing the MC, samples were submitted to FS. Normality distribution within each sample was done using Kolmogorov-Smirnov test, and the comparison between the experimental subgroups was performed using analysis of variance (ANOVA) adopting a significance level of 5% (α=0.05).

RESULTS

The FS values are shown in Table 1. The COP10 specimens had mean only about 25% of the RelyX ARC. The RX samples did not resist the mechanical cycling and fractured before the 10,000 cycles were completed. Two-way ANOVA among the subgroups of COP10 reveals no significant differences among the FS values as a function of either the “mechanical cycling” (F1,28=0.068; p=.0795) or “storage time” (F1,28=0.0558; p=.8150). One-way ANOVA identified significant differences between 24 h and 60 days of RelyX ARC storage (F1,14=24.860, p<.0002); it was observed that storage increased the flexural strength of the RX samples (Table 1).

Table 1
- Means (MPa) and standard deviations of flexural strength values of luting agents according to storage time and performance of mechanical cycling test

DISCUSSION

In this study, the null hypothesis was rejected because the FS of the COP10 was significantly different from that of the RelyX ARC, a commercially available and most widely used resin cement. Two clinical situations were assessed using conditions designed to simulate the oral environment: aging was simulated by storage in aqueous medium1212 - Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42:465-72., and chewing forces were simulated by mechanical cycling2424 - Nikaido T, Kunzelmann KH, Chen H, Ogata M, Harada N, Yamaguchi S, et al. Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin. Dent Mater. 2002;18:269-75.. The calcium carbonate filler was used because previous studies have shown its ability to provide radiopacity to the COP and to supply bactericidal and fungicidal properties to the cement, properties that can be a key factor in the selection of a dental luting agent. The addition of 10% calcium carbonate showed good results regarding diametral tensile strength and film thickness6- Carmello JC, Fais LM, Ribeiro LN, Claro Neto S, Guaglianoni DG, Pinelli LA. Diametral tensile strength and film thickness of an experimental dental luting agent derived from castor oil. J Appl Oral Sci. 2012;20:16-20..

The mechanical properties of resinous materials are directly related to the quantity and type (composition, shape, size and distribution) of the inorganic particles8- Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76:1405-11., degree of cure and percentage of silane-treated filler1212 - Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42:465-72., with the flexural strength being directly proportional to the amount of filler particles3030 - Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent. 2003;28:535-42.. The results of this study showed that, for both storage times, the flexural strength of the COP10 group was lower than that of the RelyX ARC group. This result can be explained by differences in the type and amount of filler particles in both cements.

The RelyX ARC is composed of the following: 1) an organic matrix composed of monomers, polymerization inhibitors, color modifiers and an initiator/activator system; 2) a zirconia/silica inorganic filler of approximately 67.5% by weight; 3) organo-silane as a bonding agent between the organic matrix and the filler. In contrast, the COP10 is composed of the following: 1) a matrix that results from the polymerization of polyester from vegetable polyol with linear aliphatic diisocyanates; 2) 10% (wt%) of calcium carbonate by weight as an inorganic filler. Thus, aside from the differences between the amount and type of filler, the absence of a bonding agent, which could result in the consequent failure in the linking-up of the inorganic particles with the resin matrix, could be a key factor in the lower flexural strength of the COP10. However, even though the FS mean for COP10 was only about 25% of that of RelyX ARC, the FS values were similar or slightly less than those found for luting agents such as zinc phosphate (18 MPa), glass ionomer cement (15-36 MPa) and resin-modified cement (22 MPa)2.

The specimens made from the resin cement RelyX ARC did not achieve the FS values reported by ISO Specification 4049 for light-cure composites (86±6 – 155±7 MPa) in 24 hours1818 - International Organization for Standardization. ISO 4049: Dentistry - Polymer-based restorative materials. Geneva: ISO; 2009.. However, after 60 days of storage in distilled water, this dental luting agent showed an 18% increase in FS in comparison with the values obtained after 24 hours. It has been shown in the literature that mechanical resistance results can vary as a result of different filler compositions, extent of cure and testing method used1212 - Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42:465-72.. According some authors1010 - Duymus ZY, Yanikoğlu ND, Alkurt M. Evaluation of the flexural strength of dual-cure composite resin cements. J Biomed Mater Res B Appl Biomater. 2013;101:878-81.,1212 - Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42:465-72.,2626 - Pace LL, Hummel SK, Marker VA, Bolouri A. Comparison of the flexural strength of five adhesive resin cements. J Prosthodont. 2007;16:18-24., increases in FS, even in the presence of water, could be the result of significant residual or continued polymerization that may occur in dual-cure cements.

On the other hand, after 60 days, the flexural strength of the COP10 specimens remained statistically similar to that observed after 24 hours of storage. According to the manufactures of the COP, after 1 hour, the cement has acquired strength, although it can continue to present residual polymerization for up to 36 hours after the initial mixing, thought most of the isocyanate-hydroxyl reaction is completed in 24 hours. As such, in this study, the residual polymerization that occurred between 24 and 36 hours of storage was not sufficient to significantly increase the FS values. Moreover, considering that the specimens were immersed in distilled water and that the free isocyanates may have reacted with water molecules, it was interesting that there was no decrease in FS, i.e., the long-term effect of water storage did not affect the FS of the COP10, similarly to the COP applied as an endodontic filler that had a reduced solubility in both artificial saliva and deionized water3131 - Rosa PC, Mancini MN, Camargo SE, Garrido AD, Camargo CH, Rode SM. Dimensional alterations and solubility of new endodontic sealers. Braz Dent J. 2010;21:301-4..

The results of the MC test show that the RelyX ARC fractured before 10,000 cycles. This finding may be the result of the large amount of zirconia/silica filler (67.5 wt%) incorporated into the matrix1717 - Hill EE. Dental cements for definitive luting: a review and practical clinical considerations. Dent Clin North Am. 2007;51:643-58.. This amount of filler may have influenced the fracturing of the material without the occurrence of behaviour elastic. In comparison, the COP10 showed no change in FS after mechanical cycling, possibly due to the higher elasticity provided by the proportion of polymeric matrix/filler present. The failure potential of a cemented restoration under forces is related to the mechanical properties of the individual parts (periodontal ligament, tooth, luting agent and restoration)3232 - Saskalauskaite E, Tam LE, McComb D. Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont. 2008;17:262-8.. Despite reports of success of RelyX ARC1- Aguiar TR, André CB, Correr-Sobrinho L, Arrais CA, Ambrosano GM, Giannini M. Effect of storage times and mechanical load cycling on dentin bond strength of conventional and self-adhesive resin luting cements. J Prosthet Dent. 2014;111:404-10.,2727 - Pekperdahci T, Turkoz Y, Ozan O, Seker E. The effects of different adhesive agents on the shear bond strength of a self-adhesive resin cement. J Appl Biomater Funct Mater. 2012;10:149-56., current literature shows that the comparisons based on adhesive properties and clinical data proving the longevity of crown and fixed partial dentures (FPD) cemented with RelyX ARC are still limited. Then, this in vitro study was carried out as a preliminary study to investigate and compare the behavior of the COP10 under tension, without the influence of the individual parts3232 - Saskalauskaite E, Tam LE, McComb D. Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont. 2008;17:262-8.. Future studies will be designed to assess the flexural (monotonic and fatigue) behavior of crowns or FPD cemented with these two materials in order to enhance the knowledge about COP10 and RelyX ARC.

Despite the limitations inherent to an in vitro study as well as the lower FS values of the COP10 that were observed, this dental luting agent can still be considered a promising material due to its characteristics related to biocompatibility, elasticity, mechanical strength and versatility in being modified in terms of composition and structure according to specific requirements3434 - Yaszemski MJ, Payne RG, Hayes WC, Langer R, Mikos AG. Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone. Biomaterials. 1996;17:175-85.. Moreover, Ricinus communis is a plant easily found in Brazil with great potential in the manufacturing of products derived from its oil. As such, future studies should be conducted to assess COP containing higher concentrations of CaCO3 and the addition of other fillers, such as zirconia/silica, as well as certain bonding agents. These modifications may improve its mechanical resistance, causing it to have properties similar to those of commercially available resin cements.

CONCLUSION

A castor oil-containing dental luting agent with a 10% weight percentage (wt%) of calcium carbonate resisted mechanical cycling without decreases in flexural strength. However, the COP10 showed lower flexural strength values than the RelyX ARC.

ACKNOWLEDGEMENTS

The authors thank São Paulo Research Foundation – Fapesp for financial support (# 2006/00083-0; 2006/02821-8).

REFERENCES

  • 1
    - Aguiar TR, André CB, Correr-Sobrinho L, Arrais CA, Ambrosano GM, Giannini M. Effect of storage times and mechanical load cycling on dentin bond strength of conventional and self-adhesive resin luting cements. J Prosthet Dent. 2014;111:404-10.
  • 2
    - Attar N, Tam LE, McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent. 2003;89:127-34.
  • 3
    - Bao H, Zhang ZP, Ying S. Effect of ionic group on the behaviour of polyurethaneurea emulsion. Polymer. 1996;37:2751-4.
  • 4
    - Blackman R, Barghi N, Duke E. Influence of ceramic thickness on the polymerization of light-cured resin cement. J Prosthet Dent. 1990;63:295-300.
  • 5
    - Camargo SE, Rode SM, Prado RF, Carvalho YR, Camargo CH. Subcutaneous tissue reaction to castor oil bean and calcium hydroxide in rats. J Appl Oral Sci. 2010;18:273-8.
  • 6
    - Carmello JC, Fais LM, Ribeiro LN, Claro Neto S, Guaglianoni DG, Pinelli LA. Diametral tensile strength and film thickness of an experimental dental luting agent derived from castor oil. J Appl Oral Sci. 2012;20:16-20.
  • 7
    - Carvalho TL, Araújo CA, Teófilo JM, Brentegani LG. Histologic and histometric evaluation of rat alveolar wound healing around polyurethane resin implants. Int J Oral Maxillofac Surg. 1997;26:149-52.
  • 8
    - Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76:1405-11.
  • 9
    - Council adopts American Dental Association. Specification No. 8 (dental zinc phosphate cement) and 11 (agar impression material). Council on Dental Materials and Devices. J Am Dent Assoc. 1967;74:1565-73.
  • 10
    - Duymus ZY, Yanikoğlu ND, Alkurt M. Evaluation of the flexural strength of dual-cure composite resin cements. J Biomed Mater Res B Appl Biomater. 2013;101:878-81.
  • 11
    - Fan P, Nicholls JI, Kois JC. Load fatigue of five restoration modalities in structurally compromised premolars. Int J Prosthodont. 1995;8:213-20.
  • 12
    - Ferracane JL, Berge HX, Condon JR. In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998;42:465-72.
  • 13
    - Ferreira CM, Silva Rosa OP, Torres SA, Ferreira FB, Bernardinelli N. Activity of endodontic antibacterial agents against selected anaerobic bacteria. Braz Dent J. 2002;13:118-22.
  • 14
    - Ferreira P, Pereira R, Coelho JF, Silva AF, Gil MH. Modification of the biopolymer castor oil with free isocyanate groups to be applied as bioadhesive. Int J Biol Macrom. 2007;40:144-52.
  • 15
    - Frazilio FO, Rossi R, Negrini Neto J, Facco GG, Ovando M, Fialho M. Use of castor oil polyurethane in an alternative technique for medial patella surgical correction in dogs. Acta Cir Bras. 2006;21:74-9.
  • 16
    - Freeman MA, Nicholls JI, Kydd WL, Harrington GW. Leakage associated with load fatigue-induced preliminary failure of full crowns placed over three different post and core systems. J Endod. 1998;24:26-32.
  • 17
    - Hill EE. Dental cements for definitive luting: a review and practical clinical considerations. Dent Clin North Am. 2007;51:643-58.
  • 18
    - International Organization for Standardization. ISO 4049: Dentistry - Polymer-based restorative materials. Geneva: ISO; 2009.
  • 19
    - Jowett AK, Ferguson MW, Combe EC. In vitro biocompatibility testing: a new organ culture model. J Dent. 1988;16:55-65.
  • 20
    - Leite FR, Ramalho LT. Bone regeneration after demineralized bone matrix and castor oil (Ricinus communis) polyurethane implantation. J Appl Oral Sci. 2008;16:122-6.
  • 21
    - Mannocci F, Ferrari M, Watson TF. Microleakage of endodontically treated teeth restored with fiber posts and composite cores after cyclic loading: a confocal microscopic study. J Prosthet Dent. 2001;85:284-91.
  • 22
    - Monteiro AS, Macedo LG, Macedo NL, Balducci I. Polyurethane and PTFE membranes for guided bone regeneration: histopathological and ultrastructural evaluation. Med Oral Patol Oral Cir Bucal. 2010;15:401-6.
  • 23
    - Nayak P, Mishra DK, Sahoo KC, Pati NC, Jena PK, Lenka S, et al. Polymers from renewable resources. XIII. Interpenetrating polymer networks derived from castor oil-hexamethylene diisocyanate and polymethacrylamide. J Appl Polymer Sci. 2001;80:1349-53.
  • 24
    - Nikaido T, Kunzelmann KH, Chen H, Ogata M, Harada N, Yamaguchi S, et al. Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin. Dent Mater. 2002;18:269-75.
  • 25
    - Oilo G, Espevik S. Stress/strain behavior of some dental luting cements. Acta Odontol Scand. 1978;36:45-9.
  • 26
    - Pace LL, Hummel SK, Marker VA, Bolouri A. Comparison of the flexural strength of five adhesive resin cements. J Prosthodont. 2007;16:18-24.
  • 27
    - Pekperdahci T, Turkoz Y, Ozan O, Seker E. The effects of different adhesive agents on the shear bond strength of a self-adhesive resin cement. J Appl Biomater Funct Mater. 2012;10:149-56.
  • 28
    - Pinelli LA, Montandon AA, Corbi SC, Moraes TA, Fais LM. Ricinus communis treatment of denture stomatitis in institutionalised elderly. J Oral Rehabil. 2013;40:375-80.
  • 29
    - Pinelli LA, Fais LM, Ricci WA, Reis JM. In vitro comparisons of casting retention on implant abutments among commercially available and experimental castor oil-containing dental luting agents. J Prosthet Dent. 2013;109:319-24.
  • 30
    - Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent. 2003;28:535-42.
  • 31
    - Rosa PC, Mancini MN, Camargo SE, Garrido AD, Camargo CH, Rode SM. Dimensional alterations and solubility of new endodontic sealers. Braz Dent J. 2010;21:301-4.
  • 32
    - Saskalauskaite E, Tam LE, McComb D. Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont. 2008;17:262-8.
  • 33
    - Shen C. Dental cements. In: Anusavice KJ, ed. Philips’ science of dental materials. St. Louis: Elsevier; 2003. p.471-85.
  • 34
    - Yaszemski MJ, Payne RG, Hayes WC, Langer R, Mikos AG. Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone. Biomaterials. 1996;17:175-85.

Publication Dates

  • Publication in this collection
    Nov-Dec 2014

History

  • Received
    19 Feb 2014
  • Reviewed
    21 July 2014
  • Accepted
    8 Aug 2014
Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil
E-mail: jaos@usp.br