Acessibilidade / Reportar erro

Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

ABSTRACT

Objective:

The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections.

Material and Methods:

Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05).

Results:

Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied.

Conclusions:

Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

Keywords:
Orthodontic wires; Mechanical phenomena; Elasticity; Comparative study

INTRODUCTION

Nowadays, having a natural and pleasant smile even during orthodontic treatment is one of patients' main concerns. Devices combining acceptable esthetic and adequate technical performance, satisfying both the patient and the clinician expectations, have been developed22- Birnie D. Ceramic brackets. Br J Orthod. 1990;17:71-4.. Nevertheless, esthetic brackets show higher friction coefficients than metallic brackets, which can impair the desired movement3535- Tselepis M, Brockhurst P, West VC. The dynamic frictional resistance between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop. 1994;106:131-8..

Self-ligating brackets, introduced as Russel's accessories in the mid-1930s, are systems that present a mechanical device designed to close the edgewise slot3333- Stolzenberg J. The Russell attachment and its improved advantages. Int J Orthod Dent Child. 1935;21:837-40.. Their use has become common in recent years. Manufactures claim several advantages in using these accessories, and the low friction seems to be the most studied among them1111- Gurgel JA, Kerr S, Powers JM, LeCrone V. Force-deflection properties of superelastic nickel-titanium archwires. Am J Orthod Dentofacial Orthop. 2001;120:378-82.,1515- Imai T, Watari F, Yamagata S, Kobayashi M, Nagayama K, Toyoizumi Y, et al. Mechanical properties and aesthetics of FRP orthodontic wire fabricated by hot drawing. Biomaterials. 1998;19:2195-200.,1818- Kumar S, Singh S, Hamsa PR, Ahmed S, Prasanthma, Bhatnagar A, et al. Evaluation of friction in orthodontics using various brackets and archwire combinations - an in vitro study. J Clin Diagn Res. 2014;8:ZC33-6.. Some studies confirm that there is significantly lower friction in these brackets, increasing the efficiency of the alignment, resulting in a shorter treatment time1515- Imai T, Watari F, Yamagata S, Kobayashi M, Nagayama K, Toyoizumi Y, et al. Mechanical properties and aesthetics of FRP orthodontic wire fabricated by hot drawing. Biomaterials. 1998;19:2195-200.,1919- Kusy RP. Orthodontic biomaterials: from the past to the present. Angle Orthod. 2002;72:501-12.. However, some studies showed that this reduced friction depends on the type and caliper of the wire and the degree of crowding3030- Reznikov N, Har-Zion G, Barkana I, Abed Y, Redlich M. Influence of friction resistance on expression of superelastic properties of initial NiTi wires in “reduced friction” and conventional bracket systems. J Dent Biomech. 2010;2010:613142.. Further studies and clinical evaluations are still necessary to confirm these benefits2424- Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load deflection characteristics and force level of nickel titanium initial archwires. Angle Orthod. 2012;82:507-21..

Therefore, effectiveness of orthodontic movement results not only from different bracket systems, but also from a series of other factors, related to both the patient (teeth and supporting structures) and the type of mechanics applied. Teeth movement also depends on the action of orthodontic wires, which varies according to their structural and mechanical properties33- Burstone CJ. Variable-modulus orthodontics. Am J Orthod. 1981;80:1-16..

Consequently, it is necessary to assess not only the friction related to different bracket systems, but also the behavior of different currently available orthodontic materials regarding the forces applied during orthodontic mechanics. Furthermore, the development of esthetic brackets with metal components comprises a new field for research88- De Franco DJ, Spiller RE Jr, von Fraunhofer JA. Frictional resistances using teflon-coated ligatures with various bracket-archwire combinations. Angle Orthod. 1995;65:63-72.. To make the best choice among the various brackets and orthodontic wires available, it is essential to know the magnitude of forces released by these wires and their behavior regarding the gradual increase in wire deflection77- D'Antò V, Rongo R, Ametrano G, Spagnuolo G, Manzo P, Martina R, et al. Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy. Angle Orthod. 2012;82:922-8..

This in vitro study assessed deflection forces of round Nitinol orthodontic wires, placed in conventional metallic, reinforced polycarbonate, sapphire (Ormco, Glenda, CA, USA), and self-ligating brackets by using a clinical simulation model and following ISO 15841 as protocol.

MATERIAL AND METHODS

Material - experimental groups

The sample used in this study consisted of 400 round-section Nitinol wires (Standard or Medium, GAC®, Bohemia, NY, USA) with 0.014, 0.016, 0.018, and 0.020-inch diameters and five different bracket types: conventional metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating brackets (Figure 1). Wires that showed very different behavior from the others were excluded2121- Lee SM, Hwang CJ. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type. Korean J Orthod. 2015;45:13-9.: they statistically represent outliers that would negatively interfere with the results. In conventional brackets, the wires were tied with “O” shaped elastomeric ligatures (GAC®; Bohemia, NY, USA). In the self-ligating brackets the wires were tied by closing the passive (Damon Q) or active (In-Ovation R) systems.

Figure 1
Sample used and test conditions

Methods - clinical simulation device

In order to internationally standardize the tests as adequately as possible, the methods used in this study followed the ISO 15841 Standard: Dentistry – Wires for use in orthodontics1616- International Organization for Standardization - ISO. ISO 15841: Dentistry - Wires for use in orthodontics. 1st ed. Geneva: ISO; 2006..

Deflection of the orthodontic wire was performed in a clinical simulation device representing all 10 teeth of the maxillary arch1111- Gurgel JA, Kerr S, Powers JM, LeCrone V. Force-deflection properties of superelastic nickel-titanium archwires. Am J Orthod Dentofacial Orthop. 2001;120:378-82.. Figure 2 shows the clinical simulation device that was used in this study. This device consists of a parabola shaped acrylic resin plate with fixed acrylic structures representing the maxillary teeth (Figure 2). The parabola shape was determined by the wires, reducing the risk of diverse forces arising from the deflection applied in an unexpected way. Brackets were bonded with cyanoacrylate ester gel (Super Bonder, Loctite, São Paulo, SP, Brazil), positioned in the long axis of the acrylic devices parallel to the ground and at the same height. The wires had the same length1212- Hemingway R, Williams RL, Hunt JA, Rudge SJ. The influence of bracket type on the force delivery of ni-ti archwires. Eur J Orthod. 2001;23:233-41.. The acrylic structures were fixed by means of threaded screw in the bottom of the acrylic resin plate.

Figure 2
Clinical simulation device

The tests were performed on the structure corresponding to the right maxillary central incisor (Figure 3). Unlike the others, this structure was not screwed, enabling its labio-lingual movement. It had a perforation, in which a metal cylinder was placed to activate it. The tip of the activation head, attached to the testing machine, had a rounded cut to fit the metal cylinder. Deflection of the wire was performed without changing the inter bracket distance (6 mm), since the relation deflection/force depends, among other things, on this distance. The speed of the deflection was 2 mm/min.

Figure 3
Instron universal testing machine used in this study, with a load cell of 10 N. Acrylic container adapted to the Instron device

Records of the force released by the wire deflection were made in 0.5, 1, 2, and 3 mm. Deflection of the wire attached to the bracket clinically corresponds to the beginning of treatment, when the teeth are poorly positioned and the wire is forced into the accessories slots. Depending on the degree of crowding, teeth experience more or less force to align the teeth.

The deflection tests were performed using the Universal Testing Machine (Instron 3342), with a load cell of 10 N1010- Galvão MB, Camporesi M, Tortamano A, Dominguez GC, Defraia E. Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures. Prog Orthod. 2013;14:9. (Figure 3). This load cell has an accuracy of 0.5% of the reading value with the temperature of 25°C. In this study, the load cell was maintained at this temperature. Also according to the ISO standard, the tests were always performed at the same testing temperature of 36±1°C for all test groups2626- Montasser MA, Keilig L, Bourauel C. Archwire diameter effect on tooth alignment with different bracket-archwire combinations. Am J Orthod Dentofacial Orthop. 2016;149:76-83.. To obtain this, an acrylic container with water at a temperature of 36±1°C, maintained with the aid of submersible heater with integral thermostat (Electronic Atman Heater, China) and checked by a decimal precision thermometer, with a limit of error of ± 0.2°C (Incoterm, reference 5097, São Paulo, SP, Brazil), was adapted to the testing machine2424- Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load deflection characteristics and force level of nickel titanium initial archwires. Angle Orthod. 2012;82:507-21. (Figure 3).

Statistical analyses

The sample size, according to the ISO 15841 standards, is of six specimens in each group1616- International Organization for Standardization - ISO. ISO 15841: Dentistry - Wires for use in orthodontics. 1st ed. Geneva: ISO; 2006.. To minimize the chances of any technical error and increase reliability of the results, 20 specimens were chosen for each group. Outliers were excluded through a statistical program that provides the values to be deleted2222- Lee YS, Lee SJ, An H, Donatelli RE, Kim SH. Do Class III patients have a different growth spurt than the general population? Am J Orthod Dentofacial Orthop. 2012;142:679-89.. Normal distribution was evaluated with Kolmogorov-Smirnov tests. Because all variables showed a normal distribution, one-way ANOVA and Tukey tests were used.

All statistical analyses were performed with Statistica software (Statistica for Windows – Release 7.0 - Copyright Statsoft Inc., Tulsa, OK, USA). Results were considered significant at p<0.05.

RESULTS

The deactivation forces were generally significantly higher with conventional than with self-ligating brackets, with 0.014 and 0.016-inch nickel-titanium wires, except with the activation of 2 mm, in which the opposite occurred (Tables 1 and 2). Overall, Inspire ICE showed the highest deactivation forces while In-Ovation R showed the lowest.

Table 1
Deactivation forces (cN) comparisons of the bracket types with 0.014-inch nickel-titanium wire, in progressive deflections (One-way Anova followed by Tukey tests)
Table 2
Deactivation forces (cN) comparisons of the bracket types with 0.016-inch nickel-titanium wire, in progressive deflections (One-way Anova followed by Tukey tests)

The deactivation forces were generally significantly higher with conventional than with self-ligating brackets, with 0.018-inch nickel-titanium wires (Table 3). Overall, Inspire ICE showed the highest deactivation forces while In-Ovation R showed the lowest.

Table 3
Deactivation forces (cN) comparisons of the bracket types with 0.018-inch nickel-titanium wire, in progressive deflections (One-way Anova followed by Tukey tests)

There was an inversion of the previous tendency with 0.020-inch nickel-titanium wires. The deactivation forces were generally significantly higher with self-ligating than with conventional brackets (Table 4). Overall, Damon Q showed the highest deactivation forces while Spirit showed the lowest. The forces with the Damon Q with 3 mm of activation exceeded 1000g.

Table 4
Deactivation forces (cN) comparisons of the bracket types with 0.020-inch nickel-titanium wire, in progressive deflections (One-way Anova followed by Tukey tests)

DISCUSSION

Sample and methodology

A clinical simulation device was used to approximate the laboratory results to clinical situations, providing more practical applications3232- Sakima MT, Dalstra M, Melsen B. How does temperature influence the properties of rectangular nickel-titanium wires? Eur J Orthod. 2006;28:282-91.. Even with this in mind, the specific ISO standard was used for orthodontic wires laboratory tests1616- International Organization for Standardization - ISO. ISO 15841: Dentistry - Wires for use in orthodontics. 1st ed. Geneva: ISO; 2006..

The elastic deflection test was chosen because it is clinically closest to the orthodontists' interests, since that is what they do when adapting a wire to the patient's teeth. Although engineers work with parameters such as elastic modulus and yield value, the orthodontist is more concerned about knowing the force released regarding the amount of deflection.

Results

In general, it was observed that the deactivation force increased with the increase in amount of deflection (Tables 1 to 4). These findings are consistent with other studies2929- Pesce RE, Uribe F, Janakiraman N, Neace WP, Peterson DR, Nanda R. Evaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets. Eur J Orthod. 2014;36:245-54..

The results found in different combinations of the brackets with 0.014-inch nickel-titanium wires are in agreement with other studies in the literature that have found erratic results in different deflections, large variation in the difference of force values, and significant differences between different types of devices3636- Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2002;121:483-95. (Table 1).

The self-ligating brackets, in deflection of 2 mm, presented the highest forces when compared with conventional brackets (Table 1). This result can be explained by assuming that part of the force is used to overcome the greater resistance to sliding, generated in tests with conventional bracket systems during unloading66- Cordasco G, Lo Giudice A, Militi A, Nucera R, Triolo G, Matarese G. In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment. Korean J Orthod. 2012;42:218-24.,3434- Thorstenson GA, Kusy RP. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofacial Orthop. 2002;122:295-305.. These findings are grounded in previous studies and confirm that NiTi wires, along with self-ligating bracket systems, generate significantly higher forces when compared with conventional brackets11- Badawi HM, Toogood RW, Carey JP, Heo G, Major PW. Three-dimensional orthodontic force measurements. Am J Orthod Dentofacial Orthop. 2009;136:518-28.,99- Franchi L, Baccetti T, Camporesi M, Giuntini V. Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teeth. Am J Orthod Dentofacial Orthop. 2009;136:316.e1-6..

However, in deflection of 3 mm, the self-ligating brackets presented the smallest forces, contradicting previous investigation2727- Nucera R, Gatto E, Borsellino C, Aceto P, Fabiano F, Matarese G, et al. Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations. Angle Orthod. 2014;84:541-7. (Table 1). This occurs because smaller diameter wires release smaller forces, since they are not completely pressed against the slots. In conventional brackets, even small diameter wires are pressed into the slots by the elastic tie.

Confirming previous results3131- Rino Neto J, Queiroz GV, Paiva JB, Ballester RY. Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires? Dental Press J Orthod. 2013;18:81-5., there were no differences in the discharge forces between Damon and In-Ovation self-ligating brackets with 0.014-inch NiTi wires in most deflections (Table 1). This may be a consequence of the more uniform wire mechanical locking system than the wire tying process of conventional brackets, with elastomeric ligatures3636- Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2002;121:483-95.. There may be more variation in the process of tying the elastomeric ligatures than when closing the self-ligating brackets.

The results were not standardized between different bracket combinations with 0.016-inch Nitinol wires, showing that the design of the experimental testing qualitatively and quantitatively affects the discharge forces during leveling and alignment with superelastic NiTi wires2828- Parvizi F, Rock WP. The load/deflection characteristics of thermally activated orthodontic archwires. Eur J Orthod. 2003;25:417-21.,3636- Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2002;121:483-95. (Table 2). Similarly, when these forces were evaluated in an experimental model with embedded bracket systems, the wires tended to lose their superelastic properties, showing variations of force2727- Nucera R, Gatto E, Borsellino C, Aceto P, Fabiano F, Matarese G, et al. Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations. Angle Orthod. 2014;84:541-7.. Other studies confirmed these findings2424- Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load deflection characteristics and force level of nickel titanium initial archwires. Angle Orthod. 2012;82:507-21.,2525- Montasser MA, El-Bialy T, Keilig L, Reimann S, Jager A, Bourauel C. Force loss in archwire-guided tooth movement of conventional and self-ligating brackets. Eur J Orthod. 2014;36:31-8..

The self-ligating brackets continued delivering less force in the 3 mm deflection because of the reasons previously provided (Table 2).

The results of combinations of different bracket types with 0.018-inch Nitinol wires demonstrated that Damon Q generated significantly greater forces when compared with In-Ovation R (Table 3). Other studies44- Buzzoni R, Elias CN, Fernandes DJ, Miguel JA. Assessment of surface friction of self-ligating brackets under conditions of angulated traction. Dental Press J Orthod. 2012;17:51-6.,2121- Lee SM, Hwang CJ. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type. Korean J Orthod. 2015;45:13-9. also noticed higher forces when passive (Smart Clip) were compared with active self-ligating brackets (Time3).

Finally, different bracket combinations with 0.020-inch Nitinol wires showed again that Damon Q generated greater forces than In-Ovation R (Table 4). From 1 mm of deflection, the self-ligating brackets showed greater forces than the others. This result is consistent with another study in which friction was responsible for reducing the amount of released force3636- Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2002;121:483-95.. This partially explains the fact that the highest average was generated by the simulation device with self-ligating brackets1414- Huang TH, Luk HS, Hsu YC, Kao CT An in vitro comparison of the frictional forces between archwires and self-ligating brackets of passive and active types. Eur J Orthod. 2012;34:625-32.,1717- Krishnan M, Kalathil S, Abraham KM. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys. Am J Orthod Dentofacial Orthop. 2009;136:675-82..

Clinically, this explanation makes sense because friction increases the released force during loading, but decreases it during unloading2323- Liaw YC, Su YY, Lai YL, Lee SY. Stiffness and frictional resistance of a superelastic nickel-titanium orthodontic wire with low-stress hysteresis. Am J Orthod Dentofacial Orthop. 2007;131:578.e12-8.. Therefore, the device with higher friction generated less force, because friction hinders the return of the wire to its initial position during the discharge3636- Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2002;121:483-95.. The presence of the brackets, the distance between them, the bands, and the crowding itself are factors that increase friction in the clinical setting. Thus, this large friction would be able to decrease the released force by the wire. Other studies also found higher frictional resistance of conventional brackets when compared with self-ligating ones55- Cacciafesta V, Sfondrini MF, Ricciardi A, Scribante A, Klersy C, Auricchio F Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations. Am J Orthod Dentofacial Orthop. 2003;124:395-402.,1313- Hiroce M, Fernandes DJ, Elias CN, Miguel JA. Sliding resistance of polycarbonate self-ligating brackets and stainless steel esthetic archwires. Prog Orthod. 2012;13:148-53..

Conventional and esthetic brackets showed very different patterns of forces due to bracket composition. Thus, this result should be considered when choosing the type of brackets to be used according to the type of mechanics necessary in orthodontic treatment of each case.

An important aspect to be considered is the difficulty in extrapolating laboratorial findings regarding frictional forces to the clinical environment. Many different factors, such as occlusal forces and tightening or loosening the archwire in the brackets during treatment, may produce different force values, with significant clinical relevance2020- Kusy RP, Whitley JQ. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding. Eur J Orthod. 1999;21:199-208..

CONCLUSIONS

Conventional and esthetic brackets showed very different patterns of forces due to bracket composition;

Self-ligating brackets presented similar behavior to each other and showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

REFERENCES

  • 1
    - Badawi HM, Toogood RW, Carey JP, Heo G, Major PW. Three-dimensional orthodontic force measurements. Am J Orthod Dentofacial Orthop. 2009;136:518-28.
  • 2
    - Birnie D. Ceramic brackets. Br J Orthod. 1990;17:71-4.
  • 3
    - Burstone CJ. Variable-modulus orthodontics. Am J Orthod. 1981;80:1-16.
  • 4
    - Buzzoni R, Elias CN, Fernandes DJ, Miguel JA. Assessment of surface friction of self-ligating brackets under conditions of angulated traction. Dental Press J Orthod. 2012;17:51-6.
  • 5
    - Cacciafesta V, Sfondrini MF, Ricciardi A, Scribante A, Klersy C, Auricchio F Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations. Am J Orthod Dentofacial Orthop. 2003;124:395-402.
  • 6
    - Cordasco G, Lo Giudice A, Militi A, Nucera R, Triolo G, Matarese G. In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment. Korean J Orthod. 2012;42:218-24.
  • 7
    - D'Antò V, Rongo R, Ametrano G, Spagnuolo G, Manzo P, Martina R, et al. Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy. Angle Orthod. 2012;82:922-8.
  • 8
    - De Franco DJ, Spiller RE Jr, von Fraunhofer JA. Frictional resistances using teflon-coated ligatures with various bracket-archwire combinations. Angle Orthod. 1995;65:63-72.
  • 9
    - Franchi L, Baccetti T, Camporesi M, Giuntini V. Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teeth. Am J Orthod Dentofacial Orthop. 2009;136:316.e1-6.
  • 10
    - Galvão MB, Camporesi M, Tortamano A, Dominguez GC, Defraia E. Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures. Prog Orthod. 2013;14:9.
  • 11
    - Gurgel JA, Kerr S, Powers JM, LeCrone V. Force-deflection properties of superelastic nickel-titanium archwires. Am J Orthod Dentofacial Orthop. 2001;120:378-82.
  • 12
    - Hemingway R, Williams RL, Hunt JA, Rudge SJ. The influence of bracket type on the force delivery of ni-ti archwires. Eur J Orthod. 2001;23:233-41.
  • 13
    - Hiroce M, Fernandes DJ, Elias CN, Miguel JA. Sliding resistance of polycarbonate self-ligating brackets and stainless steel esthetic archwires. Prog Orthod. 2012;13:148-53.
  • 14
    - Huang TH, Luk HS, Hsu YC, Kao CT An in vitro comparison of the frictional forces between archwires and self-ligating brackets of passive and active types. Eur J Orthod. 2012;34:625-32.
  • 15
    - Imai T, Watari F, Yamagata S, Kobayashi M, Nagayama K, Toyoizumi Y, et al. Mechanical properties and aesthetics of FRP orthodontic wire fabricated by hot drawing. Biomaterials. 1998;19:2195-200.
  • 16
    - International Organization for Standardization - ISO. ISO 15841: Dentistry - Wires for use in orthodontics. 1st ed. Geneva: ISO; 2006.
  • 17
    - Krishnan M, Kalathil S, Abraham KM. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys. Am J Orthod Dentofacial Orthop. 2009;136:675-82.
  • 18
    - Kumar S, Singh S, Hamsa PR, Ahmed S, Prasanthma, Bhatnagar A, et al. Evaluation of friction in orthodontics using various brackets and archwire combinations - an in vitro study. J Clin Diagn Res. 2014;8:ZC33-6.
  • 19
    - Kusy RP. Orthodontic biomaterials: from the past to the present. Angle Orthod. 2002;72:501-12.
  • 20
    - Kusy RP, Whitley JQ. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding. Eur J Orthod. 1999;21:199-208.
  • 21
    - Lee SM, Hwang CJ. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type. Korean J Orthod. 2015;45:13-9.
  • 22
    - Lee YS, Lee SJ, An H, Donatelli RE, Kim SH. Do Class III patients have a different growth spurt than the general population? Am J Orthod Dentofacial Orthop. 2012;142:679-89.
  • 23
    - Liaw YC, Su YY, Lai YL, Lee SY. Stiffness and frictional resistance of a superelastic nickel-titanium orthodontic wire with low-stress hysteresis. Am J Orthod Dentofacial Orthop. 2007;131:578.e12-8.
  • 24
    - Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load deflection characteristics and force level of nickel titanium initial archwires. Angle Orthod. 2012;82:507-21.
  • 25
    - Montasser MA, El-Bialy T, Keilig L, Reimann S, Jager A, Bourauel C. Force loss in archwire-guided tooth movement of conventional and self-ligating brackets. Eur J Orthod. 2014;36:31-8.
  • 26
    - Montasser MA, Keilig L, Bourauel C. Archwire diameter effect on tooth alignment with different bracket-archwire combinations. Am J Orthod Dentofacial Orthop. 2016;149:76-83.
  • 27
    - Nucera R, Gatto E, Borsellino C, Aceto P, Fabiano F, Matarese G, et al. Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations. Angle Orthod. 2014;84:541-7.
  • 28
    - Parvizi F, Rock WP. The load/deflection characteristics of thermally activated orthodontic archwires. Eur J Orthod. 2003;25:417-21.
  • 29
    - Pesce RE, Uribe F, Janakiraman N, Neace WP, Peterson DR, Nanda R. Evaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets. Eur J Orthod. 2014;36:245-54.
  • 30
    - Reznikov N, Har-Zion G, Barkana I, Abed Y, Redlich M. Influence of friction resistance on expression of superelastic properties of initial NiTi wires in “reduced friction” and conventional bracket systems. J Dent Biomech. 2010;2010:613142.
  • 31
    - Rino Neto J, Queiroz GV, Paiva JB, Ballester RY. Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires? Dental Press J Orthod. 2013;18:81-5.
  • 32
    - Sakima MT, Dalstra M, Melsen B. How does temperature influence the properties of rectangular nickel-titanium wires? Eur J Orthod. 2006;28:282-91.
  • 33
    - Stolzenberg J. The Russell attachment and its improved advantages. Int J Orthod Dent Child. 1935;21:837-40.
  • 34
    - Thorstenson GA, Kusy RP. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofacial Orthop. 2002;122:295-305.
  • 35
    - Tselepis M, Brockhurst P, West VC. The dynamic frictional resistance between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop. 1994;106:131-8.
  • 36
    - Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2002;121:483-95.

Publication Dates

  • Publication in this collection
    Sep-Oct 2016

History

  • Received
    16 Sept 2015
  • Reviewed
    31 Mar 2016
  • Accepted
    18 Apr 2016
Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil