Successful and failed mini-implants: microbiological evaluation and quantification of bacterial endotoxin

Abstract

Objectives

Using two groups of mini-implants (successful and failed) the objectives of this in vivo study were: to evaluate the microbial contamination by the checkerboard DNA-DNA hybridization technique and to quantify the bacterial endotoxin by the limulus amebocyte lysate assay.

Material and Methods

The 15 successful and 10 failed mini-implants (1.6 mm diameter × 7.0 or 9.0 mm long), placed in the maxilla and/or mandible, were obtained from 15 patients undergoing orthodontic treatment. Data were analyzed statistically by the Wilcoxon rank-sum test using the SAS software (a=0.05).

Results

All 40 microbial species were detected in both groups of mini-implants, with different frequencies. No differences were observed between the groups with respect to microbial complexes (blue, purple, yellow, green, orange, red and other species) and endotoxin quantification (p>0.05).

Conclusion

Neither microbial contamination nor endotoxin quantification was determinant for the early loss of stability of the mini-implants.

Orthodontic anchorage procedures; Microbiology; Gram-negative bacteria

Introduction

In the last decades, mini-implants have been widely used in Orthodontics as temporary bone anchorage devices to provide greater mechanical control with no need of patient cooperation11 - Pithon MM, Figueiredo DS, Oliveira DD. Mechanical evaluation of orthodontic mini-implants of different lengths. J Oral Maxillofac Surg. 2013;71(3):479-86.. According to the literature, mini-implants have a high clinical success rate (>80%)22 - Reynders R, Ronchi L, Bipat S. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop. 2009;135(5):564.e1-19.,33 - Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop. 2012;142(5):577-95.. However, there are reports of early failure involving loss of stability during the treatment44 - Freitas AO, Alviano CS, Alviano DS, Siqueira JF Jr, Nojima LI, Nojima MC. Microbial colonization in orthodontic mini-implants. Braz Dent J. 2012;23(4):422-7.. Different variables may influence the success rate and they may relate to: characteristics of the patient; characteristics, location and cleaning of the mini-implant; surgical placement technique; and orthodontic mechanics22 - Reynders R, Ronchi L, Bipat S. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop. 2009;135(5):564.e1-19.,55 - Meursinge Reynders RA, Ronchi L, Ladu L, van Etten-Jamaludin F, Bipat S. Insertion torque and success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop. 2012;142(5):596-614.. Mini-implants are placed transgingivally and are therefore directly accessible to all types of microorganisms in the oral cavity, specially bacteria associated with periodontitis and periimplantitis. These bacteria can penetrate the mini-implant, causing infection of soft and mineralized tissues, especially in patients with poor oral hygiene66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.. The colonization of mini-implant surfaces by pathogenic bacteria has been referred to as one of the contributing factors for the failure of these devices, but this possibility should be further investigated77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5..

It is known that the periodontopathogenic microbiota predominantly consists of anaerobes88 - Lakhssassi N, Elhajoui N, Lodter JP, Pineill JL, Sixou M. Antimicrobial susceptibility variation of 50 anaerobic periopathogens in aggressive periodontitis: an interindividual variability study. Oral Microbiol Immunol. 2005;20(4):244-52., mostly Gram-negative microorganisms99 - Mombelli A, Décaillet F. The characteristics of biofilms in peri-implant disease. J Clin Periodontol. 2011;38:203-13., which have endotoxin (also known as LPS due to its lipopolysaccharide nature) in their cell wall1010 - Leonardo MR, Silva RA, Assed S, Nelson-Filho P. Importance of bacterial endotoxin (LPS) in endodontics. J Appl Oral Sci. 2004;12(2):93-8.. Endotoxin is released after the death or multiplication of these bacteria and represents a major virulence factor by acting as a potent stimulus for proinflammatory cytokine expression and amplification of the host immune response1111 - Morra M, Cassinelli C, Bollati D, Cascardo G, Bellanda M. Adherent endotoxin on dental implant surfaces: a reappraisal. J Oral Implantol. 2015;41(1):10-6., resulting in the development of inflammatory reaction and bone resorption1010 - Leonardo MR, Silva RA, Assed S, Nelson-Filho P. Importance of bacterial endotoxin (LPS) in endodontics. J Appl Oral Sci. 2004;12(2):93-8.

11 - Morra M, Cassinelli C, Bollati D, Cascardo G, Bellanda M. Adherent endotoxin on dental implant surfaces: a reappraisal. J Oral Implantol. 2015;41(1):10-6.
-1212 - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7..

Microbial contamination and persistent peri-implant inflammation are two potential causes to be considered and thus microbiological analyses and detection of endotoxin on mini-implants with and without stability should be performed. This knowledge could lead to the development of strategies that can guarantee the long-term success of mini-implants.

Using two groups of mini-implants – stable (successful) and unstable (failed) – the objectives of this in vivo study were: 1) to evaluate the microbial contamination, using DNA probes for 40 bacterial species, by the checkerboard DNA-DNA hybridization (CDDH) biomolecular technique and 2) to quantify the bacterial endotoxin in both groups of mini-implants by the limulus amebocyte lysate assay.

Material and methods

After the research protocol was approved by the institutional Ethics Committee (Process #19866013.0.0000.5419), the patients or their legal representatives signed a written informed consent form for participation. The Declaration of Helsinki guidelines were followed in this investigation.

Initially, sample calculation was performed using SAS Power software and Sample Size 3.1 software for the Wilcoxon two-sample test and a test power between 0.6 and 0.887, respectively, with differences of medians between groups of 200,000 to 400,000 bacteria.

A total of 15 patients, aged between 11 and 49 years, of both genders, who were under corrective orthodontic treatment with fixed appliances at the Orthodontics Clinic were enrolled in the study within a period of 12 months. The participants had good general and oral health, were nonsmokers and had not used antibiotics or anti-inflammatory drugs within 3 months before the mini-implant removal. Two groups of mini-implants were obtained: 15 well-fixed mini-implants (successful), which were removed after completion of orthodontic mechanics or at the end of the treatment, and 10 unstable mini-implants, which were removed early because of excessive mobility and became loose before the desired tooth movement could be achieved (failed).

The mini-implants (1.6 mm diameter x 7.0 or 9.0 mm long; Neodent; Curitiba, Paraná, Brazil) were placed in the maxilla and/or mandible. All mini-implants were placed and removed by the same experient surgeon, using the same surgical technique, presented no contact with adjacent tooth roots and all devices presented primary stability immediately after placement. All patients received the same postsurgical instructions to clean the peri-implant area with a soft-bristle toothbrush during toothbrushing and rinse the mouth with an antiseptic solution once a day during the period of use of the mini-implant. The mean time of permanence in the mouth was 26.1 months for successful mini-implants and 6.7 months for failed mini-implants.

At the removal, the mini-implants were stored individually in nonpyrogenic 1.5 mL Eppendorf® Safe-Lock microcentrifuge tubes (Merck, Darmstadt, Hessen, Germany) containing 200 µL of pyrogen-free water. Each tube was labeled and vigorously agitated in a shaker (Mixtron; Toptronix, São Paulo, São Paulo, Brazil) for 30 seconds for desorption of the material adhered to mini-implant surfaces. From the 200 µL of bacterial suspension, 150 µL were centrifuged at 4,000 g for 12 minutes to eliminate the supernatant. The pellet was resuspended in 150 µL TE (Tris EDTA) buffer and 100 µL 0.5 M NaOH and stored frozen at 20°C for further processing by the CDDH technique.

The tubes with the remaining 50 µL of bacterial suspension were stored frozen at 20°C for further analysis by the limulus amebocyte lysate assay (PYROGENT™-5000; Lonza, Walkersville, Maryland, USA). As an additional control, endotoxin was quantified in 10 mini-implants removed from their original packages and not used to verify whether contamination occurred during manufacturing and/or packaging.

The presence of 40 bacterial species grouped according to the microbial complexes described by Socransky, et al.1313 - Socransky SS, Haffajee AD, Cugini MA, Smith C, Kent RL Jr. Microbial complexes in subgingival plaque. J Clin Periodontol. 1998;25(2):134-44. (1994) (Actinomyces group, purple, yellow, green, orange, red complexes and other species) was assessed in each sample using the CDDH technique1414 - Socransky SS, Smith CL, Martin L, Paster BJ, Dewhirts FE, Levin AE. “Checkerboard” DNA-DNA hybridization. Biotechniques. 1994;17(4):788-92..

The amount of bacterial endotoxin on the mini-implants, expressed in EU/mL (endotoxin units per milliliter) was quantified by the limulus amebocyte lysate PYROGENT™ 5000 (Lonza, Walkersville, Maryland, USA), following the manufacturer’s instructions1212 - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7..

Statistical analysis

A comparative analysis of the patients’ sex and age and the mean time of permanence of the mini-implants in the mouth was performed by the test of difference of means for continuous variables and test of difference of proportions (Wald test) for categorical variables, considering the individuals as clusters. The other results were analyzed by the nonparametric Wilcoxon rank-sum test considering the clusters1515 - Rosner B, Glynn RJ, Lee ML. Incorporation of clustering effects for the Wilcoxon rank sum test: a large-sample approach. Biometrics. 2003;59(4):1089-98. followed by a False Discovery Rate (FDR)1616 - Benjamini Y, Hochberg Y. Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Stat Soc Series B Stat Methodol. 1995;57:289-300. to adjust for multiple comparisons. All analyses were performed using the SAS (Statistical Analysis System) software for Windows version 9.3 (SAS Institute, Inc., Cary, North Carolina, USA). The significance level was set at 5%.

Results

The descriptive analysis of patient data showed no statistically significant difference between groups of successful and failed mini-implants with respect to sex and age. Only the mean time of permanence in the mouth of the mini-implants presented significant difference between groups (p<0.05).

All 40 microbial species of the Actinomyces group, purple, yellow, green, orange, red complexes and other species (100%) were observed in both groups, although with different frequencies (Figure 1). No significant difference (p=0.2824) was found between successful and failed mini-implants considering the frequency of the microbial complexes.

Figure 1
Percentage of occurrence of the 40 microbial species in successful and failed mini-implants

Regarding the semi-quantitative analysis (bacterial cell count), the median of number of microorganisms of the 40 species in the group of successful and failed mini-implants was 12,950,000 and 8,490,000, respectively. No significant difference was found between the groups regarding the total number of microorganisms (p=0.75480). Considering the bacterial species alone, although there was an increase for P. micra, T. denticola and E. saburreum, it was not statistically significant (p>0.05), after adjusting for multiple comparison test (FDR) (Table 1). No significant difference was observed among the bacterial complexes in the semi-quantitative analysis (Table 2).

Table 1
Detection of microorganisms in successful and failed mini-implants (MI)
Table 2
Results of the semi-quantitative analysis for detection of microorganisms in successful and failed mini-implants (MI) according to the bacterial complexes

The quantification of endotoxin revealed median values of 65,750 EU/mL for the successful mini-implants and 43,500 EU/mL for the failed mini-implants. No significant difference was found between the groups (p=0.63613) (Table 3).

Table 3
Quantification of endotoxin in successful and failed mini-implants (MI)

Bacterial endotoxin was not detected in the group of mini-implants examined immediately after removal from their packages and not used clinically (values <0.01 EU).

Discussion

Although the chronic inflammation caused by retention of bacterial biofilm has been implicated in the excessive mobility and consequent loss of mini-implants66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90., few studies have investigated microbial contamination around mini-implants used as temporary orthodontic anchorage devices44 - Freitas AO, Alviano CS, Alviano DS, Siqueira JF Jr, Nojima LI, Nojima MC. Microbial colonization in orthodontic mini-implants. Braz Dent J. 2012;23(4):422-7.,66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.,77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5..

Previous studies using microbial culture techniques, polymerase chain reaction (PCR) and microarray44 - Freitas AO, Alviano CS, Alviano DS, Siqueira JF Jr, Nojima LI, Nojima MC. Microbial colonization in orthodontic mini-implants. Braz Dent J. 2012;23(4):422-7.,66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.,77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5. have identified periodontopathogenic microorganisms in the peri-implant sulci or surfaces of mini-implants. This study evaluated the contamination of mini-implant surfaces using checkerboard DNA-DNA hybridization, as this biomolecular technique can detect, in a single analysis, 40 microbial species, including the Actinomyces group, purple, yellow, green, orange, red complexes and other species. It has been used in Orthodontics to evaluate the contamination of metallic and ceramic brackets1212 - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7.,1717 - Nelson-Filho P, Olmedo LY, Andrucioli MC, Saraiva MC, Matsumoto MA, Queiroz AM, et al. Use of the checkerboard DNA-DNA hybridisation technique for in vivo detection of cariogenic microorganisms on metallic brackets, with or without use of an antimicrobial agent. J Dent. 2011;39(7):513-7.

18 - Andrucioli MC, Nelson-Filho P, Matsumoto MA, Saraiva MC, Feres M, Figueiredo LC, et al. Molecular detection of in vivo microbial contamination of metallic orthodontic brackets by checkerboard DNA-DNA hybridization. Am J Orthod Dentofacial Orthop. 2012;141(1):24-9.
-1919 - Nelson-Filho P, Carpio-Horta KO, Andrucioli MC, Feres M, Bezerra da Silva RA, Garcia Paula-Silva FW, et al. Molecular detection of Aggregatibacter actinomycetemcomitans on metallic brackets by the checkerboard DNA-DNA hybridization technique. Am J Orthod Dentofacial Orthop. 2012;142(4):481-6. and the subgingival microbiota in patients undergoing orthodontic treatment2020 - Kim K, Heimisdottir K, Gebauer U, Persson GR. Clinical and microbiological findings at sites treated with orthodontic fixed appliances in adolescents. Am J Orthod Dentofacial Orthop. 2010;137(2):223-8..

In this study there was no significant difference in the frequency of complexes between the groups. In a previous study66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90., bacterial samples collected from the peri-implant sulcus surrounding had the 8 failed and 4 successful mini-implants subjected to a universal bacteria-directed real-time quantitative PCR for quantification in combination with a microarray-based identification of 20 selected species. A. odontolyticus and V. parvula (both from purple complex) and S. gordonii and S. mitis (both from the yellow complex) were detected in 100% of the samples of both groups. S. constellatus (orange complex), P. gingivalis (red complex) and A. actinomycetemcomitans (green complex) were not detected in either of the groups. These findings differ from those of the present study in which all 40 microbial species were detected in both mini-implant groups. Despite the methodological differences, Apel, et al.66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90. (2009) observed no differences between groups of successful and failed mini-implants regarding the total number of microorganisms or the microbial composition, and were unable to identify a specific aggressive microbiota in the failed mini-implants.

Tortamano, et al.77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5. (2012) also used PCR to assess 3 periodontopathogenic bacteria on the surfaces of 15 unstable and 16 stable mini-implants and reported very similar results to those of the present study, with a higher incidence of microorganisms in the stable mini-implants. In addition, they found no association between periodontopathogenic microorganisms and loss of stability.

It should be mentioned that neither of those studies66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.,77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5. performed a semi-quantitative analysis of each individual microorganism, making it difficult to establish a proper comparison with the present results. In this study, the semi-quantitative analysis of the microorganisms revealed no significant difference between groups for all species.

According to Lindhe and Meyle2121 - Lindhe J, Meyle J; Group D of European Workshop on Periodontology. Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology. J Clin Periodontol. 2008;35(8 Suppl):282-5. (2008), the inflammation associated with prosthetic implants due to poor oral hygiene may cause peri-implantitis, which starts in the soft tissue and extends slowly along the screw, causing mobility and consequently loss of the implant. As the progression of peri-implantitis and chronic periodontitis usually is slow and may take several years, inflammation of the gingival tissues around mini-implants might not be determinant for clinical success or failure, considering the short period of these devices in the mouth, especially in failed cases. These results agree with those of Apel, et al.66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90. (2009) and Tortamano, et al.77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5. (2012), who found no significant differences in the detection of microorganisms in mini-implants with and without stability, making bacterial contamination not determinant in this process.

The results of this study could be associated with the longer time of successful mini-implants in the mouth compared with the failed ones. Randomized clinical trials should be conducted to determine how the microbiota is established in both situations.

It is known that endotoxin has high affinity for several materials, including titanium2222 - Lieder R, Petersen PH, Sigurjónsson ÓE. Endotoxins - the invisible companion in biomaterials research. Tissue Eng Part B Rev. 2013;19(5):391-402., and that contamination with endotoxin causes the loss of orthopedic implants, inhibits initial osseointegration and induces cytokine production and osteoclast differentiation2323 - Beidelschies MA, Huang H, McMullen MR, Smith MV, Islam AS, Goldberg VM, et al. Stimulation of macrophage TNFalpha production by orthopaedic wear particles requires activation of the ERK1/2/Egr-1 and NF-kappaB pathways but is independent of p38 and JNK. J Cell Physiol. 2008;217(3):652-66.

24 - Greenfield EM, Beidelschies MA, Tatro JM, Goldberg VM, Hise AG. Bacterial pathogen-associated molecular patterns stimulate biological activity of orthopaedic wear particles by activating cognate toll-like receptors. J Biol Chem. 2010;285(42):32378-84.
-2525 - Bonsignore LA, Anderson JR, Lee Z, Goldberg VM, Greenfield EM. Adherent lipopolysaccharide inhibits the osseointegration of orthopedic implants by impairing osteoblast differentiation. Bone. 2013;52(1):93-101.. Endotoxin also plays an important role in the development of chronic periodontitis, possibly affecting the healing process and inflammation, with reduction of cell proliferation2222 - Lieder R, Petersen PH, Sigurjónsson ÓE. Endotoxins - the invisible companion in biomaterials research. Tissue Eng Part B Rev. 2013;19(5):391-402., and is associated with pathologies involving dental implants, including osseointegration failure and development of peri-implantitis1111 - Morra M, Cassinelli C, Bollati D, Cascardo G, Bellanda M. Adherent endotoxin on dental implant surfaces: a reappraisal. J Oral Implantol. 2015;41(1):10-6.,2222 - Lieder R, Petersen PH, Sigurjónsson ÓE. Endotoxins - the invisible companion in biomaterials research. Tissue Eng Part B Rev. 2013;19(5):391-402.. Additionally, recent in vitro studies confirmed the effect of endotoxin on the induction of genic expression of proinflammatory cytokines1111 - Morra M, Cassinelli C, Bollati D, Cascardo G, Bellanda M. Adherent endotoxin on dental implant surfaces: a reappraisal. J Oral Implantol. 2015;41(1):10-6. and bone resorption around contaminated prosthetic implants in an animal model2626 - Omar OM, Granéli C, Ekström K, Karlsson C, Johansson A, Lausmaa J, et al. The stimulation of an osteogenic response by classical monocyte activation. Biomaterials. 2011;32(32):8190-204.. Following the same reasoning, it could also occur with mini-implants.

The contamination of mini-implants by Gram-negative periodontopathogenic bacteria has been demonstrated66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.,77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5.. However, to the best of our knowledge, this is the first study to evaluate the contamination of these devices by endotoxin, and thus comparison of results is not possible.

Considering the importance of endotoxin in inflammation and bone resorption, the amount of endotoxin in well-retained and unstable mini-implants was quantified in this study to assess whether contamination by endotoxin, rather than implant stability, would be a determinant factor for clinical success.

The affinity of endotoxin for metallic materials has been demonstrated in two studies1212 - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7.,2727 - Knoernschild KL, Rogers HM, Lefebvre CA, Fortson WM, Schuster GS. Endotoxin affinity for orthodontic brackets. Am J Orthod Dentofacial Orthop 1999;115(6):634-9. that detected it on the surfaces of orthodontic brackets. The authors considered endotoxin contamination as a probable cause of the gingival inflammation commonly observed in patients undergoing orthodontic treatment, as the placement of brackets close to the gingival sulcus might affect endotoxin concentration, predisposing the periodontal tissues to inflammation. According to these results, both successful and failed mini-implants of both groups were heavily contaminated with endotoxin, justifying, in part, the occurrence of peri-implant soft tissue inflammation reported in clinical investigations44 - Freitas AO, Alviano CS, Alviano DS, Siqueira JF Jr, Nojima LI, Nojima MC. Microbial colonization in orthodontic mini-implants. Braz Dent J. 2012;23(4):422-7.,66 - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.,77 - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5., as the mini-implants are in intimate contact with the periodontal tissues. However, no significant difference was found between successful and failed mini-implants in this study.

Regarding the additional controls, the mini-implants examined immediately after removal from their packages and not used in the patients were free of endotoxin (<0.01 EU). As the acceptable level of endotoxin medical-hospital products is <0.5 EU2828 - U. S. Department of Health and Human Services. Food and Drug Administration. Guidance for industry pyrogen and endotoxins testing: questions and answers [Internet]. 2012. [cited 2018 25 March]. Available from: https://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM310098.pdf.
https://www.fda.gov/downloads/Drugs/Guid...
, the amount of endotoxin detected in the mini-implants of this study originated from oral bacteria that colonized the surfaces of these devices.

Nelson-Filho, et al.1212 - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7. (2011) detected endotoxin in amounts ranging from 0.09136 to >1.9000 EU/mL (median=0.6673 EU/mL) on the surface of orthodontic brackets after 30 days in the mouth. Therefore, comparison of endotoxin quantification on the surfaces of brackets, successful (median=65,750 EU/mL) and failed (median=43,500 EU/mL) mini-implants revealed a substantially greater amount of endotoxin on the bone anchorage devices. This fact has a clinical relevance because the endotoxin in contact with soft and mineralized tissues may act as a potent inductor of inflammation and bone resorption1212 - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7., reinforcing the need for rigorous oral hygiene in orthodontic patients with mini-implants. In this study, significant gingival inflammatory alterations were observed in the patients of both groups. Additionally, the medians of endotoxin detected in the failed mini-implants could be explained by the shorter time of permanence in the mouth (6.7 months) compared with the successful implants (23.1 months).

In conclusion, in the studied population, it is possible that bacterial contamination and endotoxin on the mini-implants were not determinant for their loss of stability, and other factors related to orthodontic mechanics, mini-implant location and surgical technique would be more directly involved in the early loss of mini-implants. Further in vivo studies should be conducted to elucidate the participation of these factors on the success or early loss of these orthodontic anchorage devices.

Acknowledgments

This study was supported by a grant-in-aid from the São Paulo Research Foundation (FAPESP – Process number 2011/23822-0) and a research postgraduate scholarship granted by the Coordination of Higher Education and Graduate Training (CAPES).

References

  • 1
    - Pithon MM, Figueiredo DS, Oliveira DD. Mechanical evaluation of orthodontic mini-implants of different lengths. J Oral Maxillofac Surg. 2013;71(3):479-86.
  • 2
    - Reynders R, Ronchi L, Bipat S. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop. 2009;135(5):564.e1-19.
  • 3
    - Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop. 2012;142(5):577-95.
  • 4
    - Freitas AO, Alviano CS, Alviano DS, Siqueira JF Jr, Nojima LI, Nojima MC. Microbial colonization in orthodontic mini-implants. Braz Dent J. 2012;23(4):422-7.
  • 5
    - Meursinge Reynders RA, Ronchi L, Ladu L, van Etten-Jamaludin F, Bipat S. Insertion torque and success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop. 2012;142(5):596-614.
  • 6
    - Apel S, Apel C, Morea C, Tortamano A, Dominguez G C, Conrads G. Microflora associated with successful and failed orthodontic mini-implants. Clin Oral Impl Res. 2009;20(11):1186-90.
  • 7
    - Tortamano A, Dominguez GC, Haddad AC, Nunes FD, Nacao M, Morea C. Periodontopathogens around the surface of mini-implants removed from orthodontic patients. Angle Orthod. 2012;82(4):591-5.
  • 8
    - Lakhssassi N, Elhajoui N, Lodter JP, Pineill JL, Sixou M. Antimicrobial susceptibility variation of 50 anaerobic periopathogens in aggressive periodontitis: an interindividual variability study. Oral Microbiol Immunol. 2005;20(4):244-52.
  • 9
    - Mombelli A, Décaillet F. The characteristics of biofilms in peri-implant disease. J Clin Periodontol. 2011;38:203-13.
  • 10
    - Leonardo MR, Silva RA, Assed S, Nelson-Filho P. Importance of bacterial endotoxin (LPS) in endodontics. J Appl Oral Sci. 2004;12(2):93-8.
  • 11
    - Morra M, Cassinelli C, Bollati D, Cascardo G, Bellanda M. Adherent endotoxin on dental implant surfaces: a reappraisal. J Oral Implantol. 2015;41(1):10-6.
  • 12
    - Nelson-Filho P, Valdez RM, Andrucioli MC, Saraiva MC, Feres M, Sorgi CA, et al. Gram-negative periodontal pathogens and bacterial endotoxin in metallic orthodontic brackets with or without use of an antimicrobial agent: an in vivo study. Am J Orthod Dentofacial Orthop. 2011;140(6):e281-7.
  • 13
    - Socransky SS, Haffajee AD, Cugini MA, Smith C, Kent RL Jr. Microbial complexes in subgingival plaque. J Clin Periodontol. 1998;25(2):134-44.
  • 14
    - Socransky SS, Smith CL, Martin L, Paster BJ, Dewhirts FE, Levin AE. “Checkerboard” DNA-DNA hybridization. Biotechniques. 1994;17(4):788-92.
  • 15
    - Rosner B, Glynn RJ, Lee ML. Incorporation of clustering effects for the Wilcoxon rank sum test: a large-sample approach. Biometrics. 2003;59(4):1089-98.
  • 16
    - Benjamini Y, Hochberg Y. Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Stat Soc Series B Stat Methodol. 1995;57:289-300.
  • 17
    - Nelson-Filho P, Olmedo LY, Andrucioli MC, Saraiva MC, Matsumoto MA, Queiroz AM, et al. Use of the checkerboard DNA-DNA hybridisation technique for in vivo detection of cariogenic microorganisms on metallic brackets, with or without use of an antimicrobial agent. J Dent. 2011;39(7):513-7.
  • 18
    - Andrucioli MC, Nelson-Filho P, Matsumoto MA, Saraiva MC, Feres M, Figueiredo LC, et al. Molecular detection of in vivo microbial contamination of metallic orthodontic brackets by checkerboard DNA-DNA hybridization. Am J Orthod Dentofacial Orthop. 2012;141(1):24-9.
  • 19
    - Nelson-Filho P, Carpio-Horta KO, Andrucioli MC, Feres M, Bezerra da Silva RA, Garcia Paula-Silva FW, et al. Molecular detection of Aggregatibacter actinomycetemcomitans on metallic brackets by the checkerboard DNA-DNA hybridization technique. Am J Orthod Dentofacial Orthop. 2012;142(4):481-6.
  • 20
    - Kim K, Heimisdottir K, Gebauer U, Persson GR. Clinical and microbiological findings at sites treated with orthodontic fixed appliances in adolescents. Am J Orthod Dentofacial Orthop. 2010;137(2):223-8.
  • 21
    - Lindhe J, Meyle J; Group D of European Workshop on Periodontology. Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology. J Clin Periodontol. 2008;35(8 Suppl):282-5.
  • 22
    - Lieder R, Petersen PH, Sigurjónsson ÓE. Endotoxins - the invisible companion in biomaterials research. Tissue Eng Part B Rev. 2013;19(5):391-402.
  • 23
    - Beidelschies MA, Huang H, McMullen MR, Smith MV, Islam AS, Goldberg VM, et al. Stimulation of macrophage TNFalpha production by orthopaedic wear particles requires activation of the ERK1/2/Egr-1 and NF-kappaB pathways but is independent of p38 and JNK. J Cell Physiol. 2008;217(3):652-66.
  • 24
    - Greenfield EM, Beidelschies MA, Tatro JM, Goldberg VM, Hise AG. Bacterial pathogen-associated molecular patterns stimulate biological activity of orthopaedic wear particles by activating cognate toll-like receptors. J Biol Chem. 2010;285(42):32378-84.
  • 25
    - Bonsignore LA, Anderson JR, Lee Z, Goldberg VM, Greenfield EM. Adherent lipopolysaccharide inhibits the osseointegration of orthopedic implants by impairing osteoblast differentiation. Bone. 2013;52(1):93-101.
  • 26
    - Omar OM, Granéli C, Ekström K, Karlsson C, Johansson A, Lausmaa J, et al. The stimulation of an osteogenic response by classical monocyte activation. Biomaterials. 2011;32(32):8190-204.
  • 27
    - Knoernschild KL, Rogers HM, Lefebvre CA, Fortson WM, Schuster GS. Endotoxin affinity for orthodontic brackets. Am J Orthod Dentofacial Orthop 1999;115(6):634-9.
  • 28
    - U. S. Department of Health and Human Services. Food and Drug Administration. Guidance for industry pyrogen and endotoxins testing: questions and answers [Internet]. 2012. [cited 2018 25 March]. Available from: https://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM310098.pdf
    » https://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM310098.pdf

Publication Dates

  • Publication in this collection
    10 July 2018
  • Date of issue
    2018

History

  • Received
    22 Dec 2017
  • Reviewed
    25 Mar 2018
  • Accepted
    23 Apr 2018
Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil
E-mail: jaos@usp.br