Acessibilidade / Reportar erro

Histological analysis of the repair of dural lesions with silicone mesh in rats subjected to experimental lesions

ABSTRACT

Objective

To evaluate inflammatory reaction, fibrosis and neovascularization in dural repairs in Wistar rats using four techniques: simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture.

Methods

Thirty Wistar rats were randomized in five groups: the first was the control group, submitted to dural tear only. The others underwent durotomy and simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Animals were euthanized and the spine was submitted to histological evaluation with a score system (ranging from zero to 3) for inflammation, neovascularization and fibrosis.

Results

Fibrosis was significantly different between simple suture and silicon mesh (p=0.005) and between simple suture and mesh with suture (p=0.015), showing that fibrosis is more intense when a foreign body is used in the repair. Bovine membrane was significantly different from mesh plus suture (p=0.011) regarding vascularization. Inflammation was significantly different between simple suture and bovine collagen membrane.

Conclusion

Silicon mesh, compared to other commercial products available, is a possible alternative for dural repair. More studies are necessary to confirm these findings.

Dura Mater; Meninges; Surgical procedures, operative; Thoracic surgery; Silicon; Models, animal

RESUMO

Objetivo

: Avaliar reação inflamatória, fibrose e neovascularização da reparação da lesão dural em ratos Wistar, comparando quatro diferentes técnicas: pontos simples, membrana de colágeno bovino, tela de silicone e tela de silicone associada a pontos simples.

Métodos

: Trinta ratos Wistar foram randomizados em cinco grupos: o primeiro foi um grupo controle, submetido somente à durotomia. Os outros também foram submetidos à durotomia, porém sofreram sutura simples, reparo com membrana de colágeno bovino, tela de silicone e tela de silicone com sutura. Os animais foram sacrificados, e a coluna foi submetida à avaliação histológica com um escore (variando de zero a 3) para inflamação, neovascularização e fibrose.

Resultados

: A fibrose foi significativamente diferente, comparando-se sutura simples e tela de silicone (p=0,005) e sutura simples e tela com fio de sutura (p=0,015), demonstrando que a fibrose foi mais intensa quando um corpo estranho foi utilizado na reparação. Membrana bovina foi significativamente diferente da tela mais sutura (p=0,011) em relação à vascularização. A inflamação foi significativamente diferente entre os grupos submetidos à sutura simples e ao reparo com membrana de colágeno bovino.

Conclusão

: A tela de silicone, comparada com produtos similares com disponibilidade comercial, é uma possível alternativa como protetor de dura-máter. Mais estudos são necessários para comprovar esses resultados.

Dura-Máter; Meninges; Procedimentos cirúrgicos operatórios; Cirurgia torácica; Silício; Modelos animais

INTRODUCTION

Spinal trauma and iatrogenic lesions are the most common causes for dural lesions.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.

2. Cain JE Jr., Dryer RF, Barton BR. Evaluation of dural closure techniques. Suture methods, fibrin adhesive sealant, and cyanoacrylate polymer. Spine (Phila Pa 1976). 1988;13(7):720-5.

3. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.

4. Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.
-55. Aydinli U, Karaeminoğullari O, Tişkaya K, Oztürk C. Dural tears in lumbar burst fractures with greenstick lamina fractures. Spine (Phila Pa 1976). 2001; 26(18):E410-5.) Vertebral fractures can cause dural lesions,(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.

4. Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.
-55. Aydinli U, Karaeminoğullari O, Tişkaya K, Oztürk C. Dural tears in lumbar burst fractures with greenstick lamina fractures. Spine (Phila Pa 1976). 2001; 26(18):E410-5.) in up to 19% of cases, when posterior spinal elements have also fractures associated to vertebral body explosion fractures.(44. Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.,55. Aydinli U, Karaeminoğullari O, Tişkaya K, Oztürk C. Dural tears in lumbar burst fractures with greenstick lamina fractures. Spine (Phila Pa 1976). 2001; 26(18):E410-5.) Accidental lesion of the dura mater in lumbar procedures has a prevalence between 1 to 17%.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.,22. Cain JE Jr., Dryer RF, Barton BR. Evaluation of dural closure techniques. Suture methods, fibrin adhesive sealant, and cyanoacrylate polymer. Spine (Phila Pa 1976). 1988;13(7):720-5.)Several autologous structures and synthetic materials have been used in dura mater repair. That includes autologous fat, fascia lata, lyophilized dura mater, and synthetic materials with great variability in clinical results.(66. Cantore G, Guidetti B, Delfini R. Neurosurgical use of human dura mater sterilized by gamma rays and stored in alcohol: long-term results. J Neurosurg. 1987;66(1):93-5.

7. Collins RL, Christiansen D, Zazanis GA, Silver FH. Use of collagen film as a dural substitute: preliminary animal studies. J Biomed Mater Res. 1991;25(2):267-76.
-88. Maurer PK, McDonald JV. Vicryl (polyglactin 910) mesh as a dural substitute. J Neurosurg. 1985;63(3):448-52.)

The increasing indications and the complexity of spine surgical procedures have led to an increased prevalence of dural lesions,(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.,99. Tamaki N, Shirataki K, Kojima N, Shouse Y, Matsumoto S. Tethered cord syndrome of delayed onset following repair of myelomeningocele. J Neurosurg. 1988;69(3):393-8.) particularly in reoperation procedures.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.,33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.) The lack of attention to the principles of modern surgery, the complexity of the cases, lack of experience, and the rush to complete the surgical procedure are factors that could contribute to this statistic. In the United States, the increase in the number of lumbar laminectomies performed for degenerative diseases of the intervertebral discs has been the leading cause of dural lesions, frequently occurring by the time of opening the ligamentum flavum.(1010. Morris GF, Marshall LF. Cerebrospinal fluid leaks: etiology and treatment. In: Herkowitz HN, Garfin SR, Balderston RA, et al. editors. Rothman-Simeone: The Spine. 4. ed.Philadelphia: W.B. Saunders. 1999. v 2. p. 1733-9.)

Most lesions are recognized intraoperatively. In some cases, in which the lesion is incomplete, affecting only the dura mater external layer without reaching the arachnoid, cerebrospinal fluid may not leak immediately and still occur postoperatively.(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.)According to Wang et al., immediate intraoperative repair does not increase perioperative morbidity or affect the outcomes.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.)

In dura mater repair surgeries, prevention of postoperative adhesions is an important aspect.(99. Tamaki N, Shirataki K, Kojima N, Shouse Y, Matsumoto S. Tethered cord syndrome of delayed onset following repair of myelomeningocele. J Neurosurg. 1988;69(3):393-8.) Lyophilized dura mater from human cadavers is often used as a dural substitute, and also in cases of repair of dural defects and meningomyeloceles, but the disadvantage of the transmission of infectious diseases exists.(99. Tamaki N, Shirataki K, Kojima N, Shouse Y, Matsumoto S. Tethered cord syndrome of delayed onset following repair of myelomeningocele. J Neurosurg. 1988;69(3):393-8.)

Dural repair increases around 20 to 30 minutes to the total surgery time.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.) The proper technique should be quick and easy to apply,(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.)however, lesions in the anterior or lateral regions may be more complicated, requiring other types of techniques.(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.,44. Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.) A combination of methods has been advocated by some authors.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.

2. Cain JE Jr., Dryer RF, Barton BR. Evaluation of dural closure techniques. Suture methods, fibrin adhesive sealant, and cyanoacrylate polymer. Spine (Phila Pa 1976). 1988;13(7):720-5.
-33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.)

Dural lesions have been treated successfully through primary repair followed by bed rest in dorsal decubitus.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.,33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.,44. Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.) Various forms of repair have been used, such as sutures with separate stitches,(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.,55. Aydinli U, Karaeminoğullari O, Tişkaya K, Oztürk C. Dural tears in lumbar burst fractures with greenstick lamina fractures. Spine (Phila Pa 1976). 2001; 26(18):E410-5.) continuous sutures,(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.) autologous fascia grafts,(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.) fibrin sealant,(1111. Nakamura H, Matsuyama Y, Yoshihara H, Sakai Y, Katayama Y, Nakashima S, et al. The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial. Spine (Phila Pa 1976). 2005;30(13):E347-51.) and porcine collagen matrix.(1212. Haq I, Cruz-Almeida Y, Siqueira EB, Norenberg M, Green BA, Levi AD. Postoperative fibrosis after surgical treatment of the porcine spinal cord: a comparison of dural substitutes. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004. J Neurosurg Spine. 2005;2(1):50-4.) Silicon mesh has been used in various surgical fields, we developed a silicon membrane in order to evaluate the applicability of the dural lesion.

It is very difficult to compare the different types of treatment of dural lesion because the few studies that were conducted are based on a small number of patients.(11. Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.) This study is therefore important due to the lack of consensus in the international literature about the repair methods and the new materials that are emerging for its treatment. Moreover, experimental controlled studies are rare and would help compare crucial aspects, such as inflammation, biocompatibility, neovascularization and fibrosis between distinct dural repair methods.

OBJECTIVE

To evaluate the potential of silicone mesh use in the repair of dura mater lesions comparing different techniques.

METHODS

This experimental study with rats was conducted in the Animal Experimentation Laboratory and Bioterium of the Faculdade de Medicina do ABC(FMABC) in accordance with the due legislation. It was approved by the FMABC Animal Experimentation Ethics Committee (protocol number 003/2010).

Thirty male Wistar rats (Rattus norvergicus), at least 12 week-old and weighing between 300 and 350g, were used. They were placed in groups of up to three per cage. They were maintained under environmental conditions (handling,ad libitum, periodic changing of shavings and cage cleaning), at a controlled temperature of around 28oC, with 12 hour light/dark periods and regular daily feeding with food appropriate for the species, until the end of the experiment.

The rats were evaluated for overall condition, weight, and motor skills. The following exclusion criteria were established: death following the lesion; loss of tissue in the area of the lesion; abnormalities observed macroscopically in the medullary region; lack of anal or vesical sphincter control; absence of motor activity following the lesion; and weight loss of more than 20% of the animal’s weight.

The rats were randomly separated (by draw) into five groups composed of six animals each and identified on their tails. All were submitted to lesion of the dura mater. The groups were the following: Durotomy Group, control, with rats submitted to dural lesion without subsequent treatment; Simple Suture Group, with dural lesion repaired with simple sutures; DuraGen® Group, with dural lesion repaired with bovine collagen dural substitute (DuraGen®) as a protector, without fixation; Mesh Group, with dural lesion repaired with silicone mesh as a protector, without fixation; Mesh Plus Suture Group, with dura mater lesion repaired with simple sutures and silicone mesh as a protector.

Description of the surgical technique

Intraperitoneal anesthesia was used (a solution of ketamine, 50 to 80mg/kg, with xylazine chlorhydrate 2%, 10mg/kg, and atropine, 0.05mg/kg). Deep anesthesia was confirmed by the absence of a corneal reflex and the absence of a reaction to deep pain inflicted by interdigital compression of the paws. Subcutaneous cefalotin (25mg/kg) was used for prophylactic antibiotic therapy following the anesthesia, 24 and 48 hours after creating the lesion. In rats that presented infection, the treatment was extended until the tenth day, and in cases of persistent infection, the animal was euthanized (exclusion criterion).

The same investigator operated on all the animals using a Carl Zeiss 3.5x surgical magnifier. The surgical site was exposed (Figure 1) by making a 2cm dorsal midline incision with a no. 15 scalpel blade to expose the vertebral spine from T8 to T12. The muscles inserted in the spinous processes were dissected and retracted using a bipolar coagulator, auto-static retractors, anatomical forceps, a perforating punch, a delicate Cobb rongeur, and a dura mater dissector. The dural sac was exposed by a laminectomy and a 5mm durotomy (Figure 2) was performed with a no. 15 scalpel blade, applied gently in the craniocaudal direction, and a 45° angle up to the CSF leak, without damaging the subjacent neural tissue.

Figure 1
Surgical exposure of the spinal cord

Figure 2
A 1mm incision in the dura mater with scalpel, causing lesion to the spinal cord involucrum

The repair of the dura mater was made with Prolene 6.0 sutures with an atraumatic needle, and with the aid of microdissection forceps, using simple separate stiches due to the small surgical incision.

In DuraGen® Group, Mesh Group, and Mesh Plus Suture Group, that were the groups with repair using mesh, 7mm squares of DuraGen® (R) or silicone mesh (depending on the group), rough on one surface and smooth on the other, were used (Figure 3). The rough surface was in contact with the dura mater for the purpose of adhesion and isolation of the lesion.

Figure 3
Placement of the silicon mesh over the spinal cord lesion

An approximation of the tissue, muscle, fascia, and skin planes was performed using simple sutures of nylon monofilament 4,0. Postoperative analgesia was maintained for a period of 72 hours with meloxicam (0.2%, 2mg/kg), administered subcutaneously once a day.

The rats were returned to their original cages and the following parameters were monitored: (a) motor activity, evaluated from the gait pattern outside the cage, observing any paralysis and paresis, as well as their location and predominance; (b) healing of the surgical wound, observing for the presence of any inflammatory signs, such as erythema, heat, and humidity, and for the presence of either CSF fistulas or abscedation.

The animals were sacrificed 24 days after surgery by carbon dioxide inhalation, in accordance with the current legislation, and following the precepts of theConselho Nacional de Controle de Experimentação Animal(CONCEA).

Following euthanasia, the spinal cord was removed en bloc, with a margin of 1cm at the edges, cephalic and caudal, in relation to the lesion site. The blocks were stored in bottles, identified by codes, with formaldehyde solution (10%), and sent to the Pathology Department of the Faculdade de Medicina do ABC.

Histopathological analysis

Histopathological analysis was performed using slides, stained with hematoxylin-eosin (HE) and Masson trichrome, of the cranial, central, and caudal segments of the spinal cord, viewed under a binocular optical microscope. The evaluation was conducted by a single professional using the same Nikon microscope and observing and grading (absent, mild, moderate, and severe) the cases for inflammatory infiltrate, neovascularization and fibrosis.

Six levels of cuts were analyzed for each case, and the evaluation was concentrated on the posterior quadrants of the spinal cord. At each level, five consecutive fields were studied under 200-x magnification. The slides were stained with HE and the inflammatory infiltrate and density of the neovessels were evaluated semi-quantitatively and graded as absent (zero), mild (1), moderate (2), or severe (3). In the Masson trichrome, the degree of fibrous thickening of the dura mater was evaluated semi-quantitatively as absent (zero), mild (1), moderate (2), or severe (3). The pathologist was given no information about which group of rats the spinal cords belonged to (blind evaluation).

Statistical analysis

A descriptive analysis of all study variables was conducted. The qualitative variables were presented as absolute and relative values, while the quantitative variables were presented in terms of their central tendency and dispersion values. For the variables that satisfied both of these principles, non-parametric tests (the Krusal-Wallis test) were used, at the level of alpha of 0.05, to compare the scores of the groups in relation to the variable, testing the hypotheses H0, if the scores obtained are independent from the group they belong to, and H1, if the scores obtained are dependent on the group they belong to.

RESULTS

Table 1 describes the inflammatory infiltrate findings for all the rats (general) and by the groups of animals subjected to durotomy, sutures, DuraGen®, mesh, and mesh with sutures. Table 2 describes the same analysis, but for the neovascularization findings. Fibrosis is described in table 3 and table 4 describes the comparative statistical analysis among the groups for the three variables of inflammatory infiltrate, neovascularization, and fibrosis. All tables present the averages and standard deviations of the scores resulting from the histological analyses.

Table 1
Descriptive statistics of the inflammatory infiltrate in the five study groups

Table 2
Descriptive statistics of neovascularization

Table 3
Descriptive statistics of fibrosis in the five groups evaluated

Table 4
Statistical analysis comparing the five study groups in relation to inflammatory infiltrate, neovascularization, and fibrosis

In terms of histopathological aspects, when compared with the preserved aspects of the meninges (Figure 4), in relation to the presence of fibrosis, there was a statistically significant difference between the Simple Suture versus Mesh Groups (p=0.005) and between the Simple Suture versus Mesh Plus Suture Groups, showing that fibrosis is more evident when a foreign body (mesh or DuraGen®) is used to repair the lesion, as shown in figures 5 and 6.

Figure 4
Photomicrography of a rat in Simple Suture Group (Masson trichrome, 40 X). Spinal cord is at the center, in red, enclosed by the pia mater and dura mater, stained in blue with a preserved aspect

Figure 5
Photomicrography of a rat in DuraGen® Group (Masson trichrome, 100 X). Dura mater with normal thickness in the upper half (arrow) and thick in the lower half (star)

Figure 6
Photomicrography of a rat in Mesh Group (Masson trichrome, 200 X). The arrow indicates the fibroid thickening of the dura mater, stained in blue

In relation to the presence of neovessels (Figure 7), a statistically significant difference was noted between the DuraGen®versus Mesh Plus Suture Groups (p=0.011). In relation to inflammatory infiltrate, there was a statistically significant difference between the Simple Suture versus DuraGen®Groups (p=0.006).

Figure 7
Photomicrography of a rat in Mesh Group (hematoxylin-eosin, 400x) indicated the presence of neovessels in the dura mater

DISCUSSION

The spinal cord is enclosed in three fibrous membranes. The outermost is called the dura mater; the innermost, attached to the nervous system, is called the pia mater; and the middle one, the arachnoid. The phenomena that occur following a lesion to the dural membrane, at any level of the spinal cord, are still not completely understood. There is an insufficient number of publications, and most of those that do exist have small sample populations or a low number of cases.(88. Maurer PK, McDonald JV. Vicryl (polyglactin 910) mesh as a dural substitute. J Neurosurg. 1985;63(3):448-52.) There is no consensus in the literature on the results achieved with the techniques, or the materials available on the market for dural repair. Additional research needs to be conducted to develop better experimental models of dural lesion in animals, to establish and standardize evaluation methods, and to continuously compare new dural repair techniques and materials.

The search for better forms of treatment for dural lesions requires the development of experimental models, in which the new techniques developed for human use can be reproduced, and both the effects caused by the implants and the reactions produced in the dural and spinal cord tissues can be evaluated.

There are numerous animal experimentation models for the development of dural repair techniques and materials, for testing the safety, efficacy, efficiency, and effectiveness of the implant materials, and for evaluating spinal cord degeneration in experimental models. Many investigators employ experimental models using rats. Rabbits are also used(1313. Sakas DE, Charnvises K, Borges LF, Zervas NT. Biologically inert synthetic dural substitutes. Appraisal of a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer. J. Neurosurg. 1990;73(6):936-41. Review.) and there are experimental models that use larger animals, such as dogs,(88. Maurer PK, McDonald JV. Vicryl (polyglactin 910) mesh as a dural substitute. J Neurosurg. 1985;63(3):448-52.) pigs,(1212. Haq I, Cruz-Almeida Y, Siqueira EB, Norenberg M, Green BA, Levi AD. Postoperative fibrosis after surgical treatment of the porcine spinal cord: a comparison of dural substitutes. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004. J Neurosurg Spine. 2005;2(1):50-4.) and primates.(1414. Narotam P, José S, Nathoo N, Taylon C, Vora Y. P63. Collagen matrix (Duragen) in spinal durotomy: techinique appraisal and clinical results. Spine J. 2003;3(5):147-8.) However, we decided to use Wistar rats of the Wistar breed due to the availability and quality of the animals, and the ease of handling and housing following surgery.

The surgical technique used in our study was a dural lesion in the thoracic region, even though most authors use the lumbar region(88. Maurer PK, McDonald JV. Vicryl (polyglactin 910) mesh as a dural substitute. J Neurosurg. 1985;63(3):448-52.,1515. Park YK, Tator CH. Prevention of arachnoiditis and postoperative tethering of the spinal cord with Gore-Tex surgical membrane: an experimental study with rats. Neurosurgery. 1998;42(4):813-23; discussion 823-4.) and the cranial region(1414. Narotam P, José S, Nathoo N, Taylon C, Vora Y. P63. Collagen matrix (Duragen) in spinal durotomy: techinique appraisal and clinical results. Spine J. 2003;3(5):147-8.) as the sites of choice for conducting tests with dural substitutes. The option to produce a dural lesion by performing a laminectomy in the thoracic region was chosen because it is easier to identify possible iatrogenic lesions of the spinal cord caused by the surgical technique through clinical parameters, enabling the exclusion of animals with any motor changes. We also chose the thoracic level since the vast majority of iatrogenic lesions occur at lumbar level, and lesions with dural involvement, in the case of fractures, occur with equal frequency in the lumbar and thoracic regions.(1515. Park YK, Tator CH. Prevention of arachnoiditis and postoperative tethering of the spinal cord with Gore-Tex surgical membrane: an experimental study with rats. Neurosurgery. 1998;42(4):813-23; discussion 823-4.,1616. Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.)

In our study, in order to evaluate the efficacy of dural repair using silicone mesh, we compared the dural repair techniques and commercial materials that are most often mentioned and tested in the medical literature,(1717. Narotam PK, José S, Nathoo N, Taylon C, Vora Y. Collagen Matriz (DuraGen) in dural repair: analysis of a new modified technique. Spine (Phila Pa 1976). 2004;29(24):2861-7; discussion 2868-9.) safe (contamination and reaction of the host tissue), and available in Brazil. We aimed to compare dural repair techniques using simple sutures, collagen membrane, and silicone mesh.

Dural suture is a well-established method. It can be combined with other methods. However, it has extremely variable closure techniques. The type, diameter, and material of the suture thread, and the suture technique used (number, spacing, and type of stitch) can vary. Isolated, continuous simple, or continuous anchored sutures are used.(33. Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.) The study by Megyesi et al. demonstrated greater efficacy of the simple-type suture with isolated stitches in in vitro tests to evaluate the resistance of the dura mater closure when submitted to hydrostatic pressure, and this closure option was used in our study.(1818. Megyesi JF, Ranger A, MacDonald W, Del Maestro RF. Suturing technique and the integrity of dural closures: an in vitro study. Neurosurgery. 2004; 55(4):950-4; discussion 954-5.) There is also a great possibility of variation in the suture thread used. The sutures most often used are polyamide monofilament (nylon) 4-0, Prolene 6-0, and silk 3-0. Prolene 6-0 thread with an atraumatic needle was used for the dural sutures. Closure was achieved with three to four isolated simple stitches, with spacing of approximately 2mm between them, due to the small size of the neural structures.

DuraGen® bovine collagen membrane was chosen because of its viability and easy of use. It is not sutured to the dura mater (the material is not suturable); its fixation is achieved by placing it directly on the lesion site and applying drops of 9% NaCl saline solution. The use of DuraGen® as a substitute or sealant for dural defects is considered to be safe in terms of contamination and reactions of the host tissue.(1717. Narotam PK, José S, Nathoo N, Taylon C, Vora Y. Collagen Matriz (DuraGen) in dural repair: analysis of a new modified technique. Spine (Phila Pa 1976). 2004;29(24):2861-7; discussion 2868-9.)

In our study, we compared two groups (sutures and DuraGen®) with the silicone mesh with and without fixation with sutures, and observed that as to the inflammatory infiltration, the silicone mesh caused less of an inflammatory reaction, on average, than DuraGen®, and a similar reaction to that of sutures. Knowing that in some cases, simple sutures are not feasible for the closure of dura mater due to the large size of the lesion, both silicone mesh and DuraGen® can be options for replacement of the membrane surrounding the spinal cord. Concerning neovascularization, there was a statistically significant difference between the DuraGen® and Silicone Mesh Plus Suture Groups. The results of Silicone Mesh Plus Suture were significantly different from those of DuraGen® in terms of inflammatory infiltrate and neovascularization, and different from simple sutures as to fibrosis.

The main limitations of our study were as follows: the possible different timing of the scar tissue process comparing the animal model to humans and, secondly, the short post-operative period of observation before the rats became sacrificed. We found no studies detailing the late results of experimental silicone mesh repair and neither scientific data about the costs involved with this technique. More studies including meta-analysis and systematic reviews are necessary to better evaluate, compare and confirm these results proving the value of silicone mesh in dural lesions difficult to repair.

CONCLUSIONS

When compared to other similar commercially-used products, silicone mesh showed potential for use as a dura mater protector, but further studies are necessary to confirm these initial results.

ACKNOWLEDGEMENTS

The authors are grateful for the financial support from Fundação de Amaparo a Pesquisa do Estado de São Paulo (FAPESP), protocol number 2013/00902-4.

REFERENCES

  • 1
    Wang JC, Bohlman HH, Riew KD. Dural tears secondary to operations on the lumbar spine. Management and results after a two-year-minimum follow-up of eighty-eight patients. J Bone Joint Surg Am. 1998;80(12):1728-32.
  • 2
    Cain JE Jr., Dryer RF, Barton BR. Evaluation of dural closure techniques. Suture methods, fibrin adhesive sealant, and cyanoacrylate polymer. Spine (Phila Pa 1976). 1988;13(7):720-5.
  • 3
    Bosacco SJ, Gardner MJ, Guille JT. Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res. 2001;(389):238-47. Review.
  • 4
    Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.
  • 5
    Aydinli U, Karaeminoğullari O, Tişkaya K, Oztürk C. Dural tears in lumbar burst fractures with greenstick lamina fractures. Spine (Phila Pa 1976). 2001; 26(18):E410-5.
  • 6
    Cantore G, Guidetti B, Delfini R. Neurosurgical use of human dura mater sterilized by gamma rays and stored in alcohol: long-term results. J Neurosurg. 1987;66(1):93-5.
  • 7
    Collins RL, Christiansen D, Zazanis GA, Silver FH. Use of collagen film as a dural substitute: preliminary animal studies. J Biomed Mater Res. 1991;25(2):267-76.
  • 8
    Maurer PK, McDonald JV. Vicryl (polyglactin 910) mesh as a dural substitute. J Neurosurg. 1985;63(3):448-52.
  • 9
    Tamaki N, Shirataki K, Kojima N, Shouse Y, Matsumoto S. Tethered cord syndrome of delayed onset following repair of myelomeningocele. J Neurosurg. 1988;69(3):393-8.
  • 10
    Morris GF, Marshall LF. Cerebrospinal fluid leaks: etiology and treatment. In: Herkowitz HN, Garfin SR, Balderston RA, et al. editors. Rothman-Simeone: The Spine. 4. ed.Philadelphia: W.B. Saunders. 1999. v 2. p. 1733-9.
  • 11
    Nakamura H, Matsuyama Y, Yoshihara H, Sakai Y, Katayama Y, Nakashima S, et al. The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial. Spine (Phila Pa 1976). 2005;30(13):E347-51.
  • 12
    Haq I, Cruz-Almeida Y, Siqueira EB, Norenberg M, Green BA, Levi AD. Postoperative fibrosis after surgical treatment of the porcine spinal cord: a comparison of dural substitutes. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004. J Neurosurg Spine. 2005;2(1):50-4.
  • 13
    Sakas DE, Charnvises K, Borges LF, Zervas NT. Biologically inert synthetic dural substitutes. Appraisal of a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer. J. Neurosurg. 1990;73(6):936-41. Review.
  • 14
    Narotam P, José S, Nathoo N, Taylon C, Vora Y. P63. Collagen matrix (Duragen) in spinal durotomy: techinique appraisal and clinical results. Spine J. 2003;3(5):147-8.
  • 15
    Park YK, Tator CH. Prevention of arachnoiditis and postoperative tethering of the spinal cord with Gore-Tex surgical membrane: an experimental study with rats. Neurosurgery. 1998;42(4):813-23; discussion 823-4.
  • 16
    Carl AL, Matsumoto M, Whalen JT. Anterior dural laceration caused by thoracolumbar and lumbar burst fractures. J Spinal Disord. 2000;13(5):399-403.
  • 17
    Narotam PK, José S, Nathoo N, Taylon C, Vora Y. Collagen Matriz (DuraGen) in dural repair: analysis of a new modified technique. Spine (Phila Pa 1976). 2004;29(24):2861-7; discussion 2868-9.
  • 18
    Megyesi JF, Ranger A, MacDonald W, Del Maestro RF. Suturing technique and the integrity of dural closures: an in vitro study. Neurosurgery. 2004; 55(4):950-4; discussion 954-5.

Publication Dates

  • Publication in this collection
    Oct-Dec 2015

History

  • Received
    28 Apr 2014
  • Accepted
    4 Nov 2015
Instituto Israelita de Ensino e Pesquisa Albert Einstein Avenida Albert Einstein, 627/701 , 05651-901 São Paulo - SP, Tel.: (55 11) 2151 0904 - São Paulo - SP - Brazil
E-mail: revista@einstein.br