Acessibilidade / Reportar erro

Lateral strength force of URM structures based on a constitutive model for interface element

Abstract

This paper presents the numerical implementation of a new proposed interface model for modeling the behavior of mortar joints in masonry walls. Its theoretical framework is fully based on the plasticity theory. The Von Mises criterion is used to simulate the behavior of brick and stone units. The interface laws for contact elements are formulated to simulate the softening behavior of mortar joints under tensile stress; a normal linear cap model is also used to limit compressive stress. The numerical predictions based on the proposed model for the behavior of interface elements correlate very highly with test data. A new explicit formula based on results of proposed interface model is also presented to estimate the strength of unreinforced masonry structures. The closed form solution predicts the ultimate lateral load of unreinforced masonry walls less error percentage than ATC and FEMA-307. Consequently, the proposed closed form solution can be used satisfactorily to analyze unreinforced masonry structures.

masonry wall; interface element; softening behavior; micro modeling; cap model; tensile strength of mortar joint


ARTICLES

Lateral strength force of URM structures based on a constitutive model for interface element

A.H. Akhaveissy* * Author email: Ahakhaveissy@razi.ac.ir

Department of Civil Engineering, Faculty Engineering, Razi University, P.O. Box 67149–67346, Kermanshah, Iran

ABSTRACT

This paper presents the numerical implementation of a new proposed interface model for modeling the behavior of mortar joints in masonry walls. Its theoretical framework is fully based on the plasticity theory. The Von Mises criterion is used to simulate the behavior of brick and stone units. The interface laws for contact elements are formulated to simulate the softening behavior of mortar joints under tensile stress; a normal linear cap model is also used to limit compressive stress. The numerical predictions based on the proposed model for the behavior of interface elements correlate very highly with test data. A new explicit formula based on results of proposed interface model is also presented to estimate the strength of unreinforced masonry structures. The closed form solution predicts the ultimate lateral load of unreinforced masonry walls less error percentage than ATC and FEMA-307. Consequently, the proposed closed form solution can be used satisfactorily to analyze unreinforced masonry structures.

Keywords: masonry wall, interface element, softening behavior, micro modeling, cap model, tensile strength of mortar joint.

1 INTRODUCTION

Masonry is the oldest building material that still finds wide use in today's building industries. Masonry buildings are constructed in many parts of the world where earthquakes occur. Hence, knowledge of their seismic behavior is necessary to evaluate the seismic performance of these types of building. Pushover analysis is commonly used to evaluate seismic performance and to determine the capacity curve. Therefore, the capacity curve is studied in this paper.

Important new developments in masonry materials and applications have occurred in the past two decades. Masonry is a composite material that consists of block and mortar joints. Hence, micro-modeling is used for the detailed analysis of masonry and may include a representation of clay bricks, mortar and the block/mortar interface, Fig. 1(a).


The primary aim of micro-modeling is to closely represent masonry using knowledge of the properties of each constituent and the interface. The necessary experimental data must be obtained from laboratory tests on the constituents and small masonry samples. Several attempts to use interfaces for the modeling of masonry were carried out in the past decade with reasonably simple models; see Lourenço (1994) for reference [8]. In particular, gradual softening behavior and all failure mechanisms, namely tensile, shear and compressive failure, have not yet been fully included. Riddington and Naom, in 1994 [13], used the finite element method to predict the ultimate compressive strength of a masonry prism. They used the bi-linear criterion to model the behavior of a mortar joint. The cap model was not used to limit the compressive and tensile strength of the mortar joint. Lourenco in 1996 [9] carried out finite element analysis with the use of the non-associated flow rule. The yield surface included the tension cut-off criterion with a compressive spherical cap model to introduce the behavior of the mortar joint; the coulomb friction criterion was also used as a potential surface [9]. The predicted load-displacement curve was in accordance with experimental data for a low initial vertical load on the wall. The contact elements with four nodes and triangular elements were implemented to analyze masonry deep beams and shear masonry walls by Sutcliffe et al. [17]. They reintroduced the yield surface used by Lourenco in [9]. They estimated the linear approximation to the cap model instead of Lourenco's spherical cap model for compressive strength. The slope of the linear approximation to the cap model was less than the frictional angle of the mortar joint. Giambanco et al. [6] implemented the tension cut-off criterion for the tensile strength and Mohr-Coulomb criterion for the shear failure mode without the compressive cap model. An asperity model was adopted to describe the evolution of the contact surface shape during the loss of cohesion process and sliding. Olivirea and Lourenco developed the model presented in [9] for cyclic loading. The limit analysis of the masonry structure was implemented by modeling nonassociative Coulomb sliding friction [7]. Chaimoon and Attard [4] carried out analysis of a masonry wall with the model introduced in [17]; however, they implemented the model with different slope angles for the linear approximation to the cap model. Shieh-Beygi and Pietruszczak [16] adopted a mesoscale approach to analyze masonry walls. The non-associated flow rule was used in the analysis. The tension cut-off model was approximated with three lines in the normal stress-shear stress space without using the compressive cap model for the yield/failure surface, and a logarithmic plastic potential surface was also employed in the analysis. They assumed the conditions at failure for both brick and mortar to be governed by the Mohr-Coulomb criterion. Thanoon et al. [18] implemented the cohesion-less Mohr-Coulomb criterion to analyze interlocking mortarless block masonry systems. Senthivel and Lourenco [15] implemented the model in [9] to analyze stone masonry shear walls. The obtained results show good agreement with test data. Brasile et al. [2] proposed a coarse-scale model based on an assumed stress finite element formulation. They obtained the nonlinear behavior by assuming a set of planes on the element where the frictional response can take place, together with the tensile and compression limit stress.

In accordance with the research above on the numerical analysis of masonry walls by the use of micro modeling processes, the models can be divided into groups: 1) one group used the tension cut-off model with the compressive cap model for the mortar joint and elastic behavior of a block [7, 13, 18], 2) another group used the tension cut-off model without the compressive cap model for the mortar joint for either the elastic-plastic behavior for block masonry [2, 16] or the elastic behavior for block masonry [6], and 3) the final group implemented the tension cut-off model with the compressive cap model for mortar joints and the elastic behavior of block masonry [4, 8, 9, 11, 15, 17]. Therefore, based on these divisions, it is necessary to investigate masonry walls with the use of the tension cut-off model with the compressive cap model and elastic-plastic behavior for block masonry with a simple formulation. This paper focuses on masonry walls with this aim.

2 THE INTERFACE MODEL

Masonry is a composite material that consists of units and mortar joints. A masonry wall is constructed by laying pieces of bricks on top of each other with cohesion via mortar. The mortar joint can be modeled by interface elements and bricks by isoparametric elements. Sliding on mortar joints may occur for a masonry wall under a lateral force. Modeling of this phenomenon with standard finite elements would lead to numerical ill conditioning due to the high aspect ratios present. The idea of overcoming this problem by introducing special elements is not new [8]. However, in this paper, the joint elements were developed by Giambanco et al. [6] and [2, 16]. Sekiguchi [14] applied 6-noded joint elements in an elasto-viscoplasticity analysis based on tangential and normal stiffness of joint elements related to the force-displacement relationship. Here, a 6-noded joint element is reformulated based on tangential and normal elasticity modules related to the stress-strain relationship, as shown in Fig. 2.


The elastic stiffness matrix of a joint element is defined in the standard finite element as

where the B matrix is defined as

The evaluation of Ke in (1) can be performed as a line integral:

where t is width of joint element, and D is the stress-strain matrix in the local coordinate system. The elastic stress-strain relation is defined as

Here we note that ET and En are tangential and normal elastic modules, respectively, in the local coordinates of the joint element, and r is illustrated as

where the shape functions ni associated with node I are expressed in terms of the local ξ coordinate as

Irreversible discontinuous displacements occur when the stress state reaches a limit condition. In this paper, the elastic domain is defined by three convex limit surfaces intersecting in a non-smooth fashion: the Coulomb criterion for the shear stress state, the tension cut-off for the tensile stress state and the compression cut-off for compressive strength. The limit functions, reported in the stress space, as shown in Fig. 3, take the following form:

where φ is the internal friction angle of the contact layer, ε is the normal strain, C, S and FC are cohesion, tensile strength and compressive strength of the contact layer, respectively, and σn, τn are the amount of normal stress and shear stress on the interface surface, respectively. These stresses are calculated in local coordinates.


The stresses will be calculated for step n and iteration i+1 based on the amount of stresses in step n and iteration i by use of the elastic predict-plastic correction as

By substituting Eq. (8) in Eq. (7), the predicted stresses are found to be

3 FINITE ELEMENT ANALYSIS

To test the effectiveness of the proposed interface laws for the solution of boundary value problems regarding masonry walls, which are made up of blocks connected to each other by mortar joints, the finite element method has been chosen to obtain the discretized version of the equilibrium equations. In finite element analysis, two-dimensional 8-nodes isoparametric elements simulating blocks and 6-nodes simulating contact elements are used for the mortar joints and units. For this purpose the program was in the FORTRAN language. The Von-Mises criterion was assumed for the behavior of blocks, and the proposed yield/failure surface was applied for the behavior of mortar joints. Three Lobatto points were considered for each contact element, and 2*2 gauss points for the 8-nodes isoparametric elements were used to carry out the numerical integrations. This method and the program were applied for modeling a number of experimental tests, and two examples are considered in the following section.

3.1 Numerical Example

3.1.1 The masonry shear wall example

This example simulates the mechanical response of the masonry wall illustrated in Fig. 4. Experimental tests on a masonry wall were carried out by Vermeltfoort et al. [19]. The wall was made of wire-cut solid clay bricks with dimensions of 210*52*100 mm3 and 10-mm thick mortar joints and characterized by a height/width ratio of one, with dimensions of 1000*990 mm2. Two stiff steel beams at the horizontal boundaries of the test setup clamp on the top and the bottom wall. The geometry of the model and the boundary conditions adopted are shown in Fig. 4. At the top horizontal side of the wall, the vertical degrees of freedom are constrained using a uniform distribution of springs of stiffness k simulating the stiffness of the test apparatus [6].


The elastic properties of the bricks as well as the joint with the interface parameters characterizing the strength properties are reported in Table 1. Fig. 5 shows the softening behavior of mortar in tension and the behavior of mortar in compression. The behavior of bricks is assumed to be elastic-perfect plastic. The behavior is modeled by the Von-Mises criterion.


Here, E is the elastic modulus, Et the tangential modulus, υ the Poission ratio, Fc the compressive strength, Ft the tensile strength, C the shear strength and ϕ the friction angle.

The value of the stiffness k has been previously calibrated to obtain a final collapse of the wall for a slip type mechanism [6]. The value of the stiffness k = 9*104 N/cm adopted to simulate the constraint was provided by the test apparatus. For the numerical analysis, bricks are represented by plane stress continuum elements (8-noded), whereas line interface elements (6-noded) are adopted for the joints. Each brick is modeled with 2*1 elements. The wall is modeled by 160 8-noded isoparametric elements, 222 interface elements and 2086 degrees of freedom. The value of error for the displacement convergence criterion is 1e-5. Fig. 6 shows the comparison between the predicted load-displacement curve and the test data. The comparison expresses significant relation between the predicted results and the test data.

Fig. 6


The variation of shear stress for point A from Fig. 6 in the isoparametric elements and interface elements is shown in Fig. 8, in the same way the variation of normal stress is shown in Fig. 9.



Fig. 8 shows distribution of the shear stress in the direction of the diagonal of the wall, BC, and the distribution of normal stress is expressed in Fig. 9. In both Fig. 8 and Fig. 9, the width of the compressive diagonal is shown with the parameter W, which is about 60 cm or 40% of the length of the diagonal.

3.1.2 The stone-masonry shear wall example

The irregular stone masonry with bonding mortar is representative of large stone block construction, possibly in monumental buildings. The data were obtained from the ancient stone masonry shear wall test [15]. The average compressive strength, tensile strength and Young's modules of the stone were 69.2 N/mm2, 2.8 N/mm2 and 20200 N/mm2, respectively. The average compressive strength of the mortar was 3.0 N/mm2. Fig. 10 and Table 2 present the experimental stone-masonry shear wall test. The dimensions of the wall were fixed as 1000 mm (length) * 1200 mm (height) * 200 mm (width), and the height to length ratio was 1.2. The dimensions of the sawn stone used in the wall were 200 mm (length) * 150 mm (height) * 200 mm (width). The monotonic lateral load was carried out with a low axial pre-compression load level of 100 kN (σ0 = 0.5 N/mm2).


Fig. 11 shows the softening behavior of mortar in tension and the behavior of mortar in compression.


For the numerical analysis, stone masonry units are represented by plane stress continuum elements (8-noded), whereas line interface elements (6-noded) are adopted for the joints. Each stone masonry unit is modeled with 2*1 elements. The wall is modeled by 48, 8-noded isoparametric elements, 60 interface elements and 1024 degrees of freedom, and the value of error for the displacement convergence criterion is 1e-4. Fig. 12 shows the comparison between predicted load-displacement curve and test data. The comparison expresses close relationship between the predicted results and test data.


The variation of the shear stress for point A from Fig. 12 in the isoparametric elements and interface elements is shown in Fig. 13. The variation of normal stress is shown in Fig. 14 too.



Fig. 13 shows that the maximum shear stress occurred above the diagonal of the wall, BC, which is in accordance with the failure observed in the laboratory [15]. In Fig. 13, the width of the compressive diagonal is shown with the parameter W, which is about 470 mm or 30% of the length of the diagonal. The maximum normal tensile stress shows the tensile failure of mortar joints and no crushing in the mortar joints due to compressive stress; see Fig. 14.

Therefore, in accordance with two different above boundary value problems, the width of the compressive diagonal can be shown as a coefficient of the length of the diagonal. Also, this coefficient by use of parameters in Table 1 was determined for a height/width ratio of two, with dimensions of 100*50 cm2 and the ratio of four, with dimensions of 200*50 cm2. The thickness of the wall was 10 cm. The coefficient for the ratio two and four was determined 0.22 and 0.12, respectively. Fig. 15 shows variations of the coefficient versus different height/width ratio of the wall. This coefficient is shown by Fw.


Therefore, the resistance lateral force of unreinforced masonry wall can be determined based on the effective width of the wall in compression. Hence, the resistance lateral force is based on compressive axial force of the effective width, Fig. 16.


According to Fig. 16, the resistance lateral force is as follows:

where, C and ϕ are the cohesive strength and the friction angle, respectively. In Eq. (10), σ0 is the initial applied pressure on the top of the wall. The lateral resistance force of two previous boundary value problems are determined based on Eq. (10), see Table 3.

The comparisons between predictions by Eq. (10) and test data in Table 3 show good correlation. To assess the ability of the proposed formula, Eq. (10), different experimental results were selected in Table 4.

The ultimate lateral force and error percentage presented by [5] were calculated based on ATC [1]. Table 4 shows that maximum error percentage of predicted lateral resistance force by Eq. (10) was about 15%, however the maximum error percentage from [5] based on ATC [1] was about 49%.

To assess the ability of the proposed formula, Eq. (10), predictions between results by Eq. (10) and ATC and FEMA-307 [1] are compared in Table 5. The thickness for all of the walls in Table 5 is the same as 250 mm.

Comparing amount of error between prediction by ATC [1] and Eq. (10) with test data in Table 5 shows that the predictions by Eq. (10) estimate the lateral resistance force well. Therefore, according to Table 3 to 5, Eq. (10) may be used to estimate the lateral resistance force of unreinforced masonry walls instead of expressed formulations in ATC and FEMA-307.

A single-story unreinforced masonry building

A full-scale single-story unreinforced masonry building tested in the laboratory by Paquette and Bruneau [12] was chosen to validate the model. Fig 17 shows the west wall of the tested model. The parapet of the west wall and the east wall was 254 mm tall [12].


The compressive strengths of the brick and mortar were 109 and 9.24 MPa, respectively, and the compressive and tensile strengths of the masonry were 22.2 and 0.18 MPa, respectively [12]. These strengths are used here for the numerical analysis of the west wall. The modulus of elasticity of the masonry specimen was assumed to be 850 times the compressive strength of the masonry specimen [3, 12]. The thickness of the wall was 190 mm. The gravity load, 2.4 kN/m2, was applied on the diaphragm, whose dimensions were 4091 mm * 5610 mm. Ten wood joists were applied to the diaphragm to transmit the gravity load to the west and east walls. The net span of the wood joist was 5310 mm [12]. Therefore, the gravity load on each wall was 6.37 kN/m.

The Drucker-Prager criterion is used to determine the cohesion strength and the friction angle of the mortar joints. As it is observed from Fig. 7, the failure of the mortar joint usual is occurred in tension. Hence the tensile strength of mortar joints, i.e. 0.18 MPa, is used to calculate the cohesion strength and the friction angle. Therefore, an infinitesimal element is analyzed under shear stress by the Drucker-Prager Criterion to determine these parameters. It is noticeable that the principle stress in principle stresses space in solid mechanics was the same as the shear stress if applied stress on the element was only shear stress. Therefore, loading on the element level is selected to be only shear stress as cyclic loading. Fig. 18 shows shear stress - shear strain curve of the element under cyclic loading for the cohesion strength and the friction angle equal to 0.078 MPa and 31.9 degree, respectively.

Fig. 18


The shear strength for all piers is calculated in Table 6 in accordance with Fig. 19. The initial applied vertical stress on the top of the east wall by dividing uniform load to the thickness is 0.0335 MPa. The ultimate shear stress is calculated based on Eq. (10) is as:

τu = C + σ0 tan(ϕ) = 0.078 + 0.0335 * tan(31.9) = 0.0988 MPa

The data analysis show the difference between the predicted shear strength of the east wall is 25.73 kN with test data, 26 kN. The comparison between the predicted shear strength of the east wall with test data [12] shows error about 1%. Therefore, the proposed closed form solution, Eq. (10), can be used satisfactorily to analyze practical masonry structures similar to those considered herein.

4 CONCLUSION

The paper presents the numerical implementation of a new proposed interface model for modeling the mechanical response of mortar joints in masonry walls. The interface laws are formulated in the framework of elasto-plasticity for non standard materials with softening which occurs in mortar joints due to applied shear and tensile stresses. Its theoretical framework is fully based on the plasticity theory. The finite element formulation is based on eight noded isoparametric quadrilateral elements and six noded contact elements. The Von Mises criterion is assumed to simulate the behavior of the units. The interface laws for contact elements are formulated to simulate the softening behavior of mortar joints under tensile stress; a normal linear cap model is also used to limit compressive stress. The capabilities of the interface model and the effectiveness of the computational procedure are investigated by making use of numerical examples that simulate the response of a masonry wall tested under shear in the presence of an initial pre-compression load. Experimental results are provided in the literature to compare with numerical analysis results. The computer predictions correlate very well with the test data. The predicted ultimate load of the masonry wall is estimated to be about 93.25% of the ultimate load according to the test data. The width of the compressive diagonal is about 40% of the length of the diagonal. The proposed model is applied to simulate a stone masonry shear wall. The predicted load-displacement curve is in accordance with the observed data, and diagonal failure is predicted with the use of the distribution of stresses in the stone masonry wall. The width of the compressive diagonal for stone masonry shear wall is about 30% of the length of the diagonal. In addition, a closed form solution was proposed based on the solid mechanics and the compressive effective width of the wall. The closed form solution is better than ATC and FEMA-307 in which predicts the ultimate lateral load of unreinforced masonry walls relatively well. Then it can be concluded that the proposed close form solution can be used satisfactorily to analyze masonry structures similar to those considered herein.

Received 25 Apr 2011;

In revised form 27 Jul 2011

  • [1] Applied Technology Council (ATC). Evaluation of earthquake damaged concrete and masonry wall buildings Federal Emergency Management Agency, Washington (DC), 1999. Technical Resources.
  • [2] S. Brasile, R. Casciaro, and G. Formica. Finite element formulation for nonlinear analysis of masonry walls. Computers and Structures, 88:135143, 2010.
  • [3] Canadian Standard Association (CSA), Ontario, Canada. Design of masonry structures, 2004.
  • [4] K. Chaimoon and M. M. Attard. Modeling of unreinforced masonry walls under shear and compression. Engineering Structures, 29:20562068, 2007.
  • [5] S. Y. Chen, F. L. Moon, and T. Yi. A macro element for the nonlinear analysis of in-plane unreinforced masonry piers. Engineering Structures, 30:22422252, 2008.
  • [6] G. Giambanco, S. Rizzo, and R. Spallino. Numerical analysis of masonry structures via interface models. Comput. Methods Appl. Engrg., 190:64936511, 2001.
  • [7] M. Gilbert, C. Casapulla, and H. M. Ahmed. Limit analysis of masonry block structures with non-associative frictional joints using linear programming. Computers and Structures, 84:873887, 2006.
  • [8] P. B. Louren¸co. Analysis of masonry structures with interface elements: Theory and applications. Technical Report 03-21-22-0-01, Delft University of Technology, Delft, The Netherlands, 1994.
  • [9] P. B. Loureno. Computational strategies for masonry structures. Thesis Delft University of Technology Delft University Press, 1996.
  • [10] G. Magenes and G. M. Calvi. In-plane seismic response of brick masonry walls. Earthquake Engineering and Structural Dynamics, 26:10911112, 1997.
  • [11] D. V. Oliveira and P. B. Lourenco. Implementation and validation of a constitutive model for the cyclic behaviour of interface elements. Computers and Structures, 82:14511461, 2004.
  • [12] J. Paquette and M. Bruneau. Pseudo-dynamic testing of unreinforced masonry building with flexible diaphragm. Journal of Structural Engineering (ASCE), 129(6):708716, 2003.
  • [13] J. R. RIDDINGTON and N. F. NAOM. Finite element prediction of masonry compressive strength. Computers & Structures, 52:113119, 1994.
  • [14] K. Sekiguchi, R. K. Rowe, K. Y. Lo, and T. Ogawa. Time step selection for 6-noded nonlinear joint element in elasto-viscoplasticity analysis. Computer and Geotechnics, 10:3358, 1990.
  • [15] R. Senthivel and P. B. Louren¸co. Finite element modelling of deformation characteristics of historical stone masonry shear walls. Engineering Structures, 31:19301943, 2009.
  • [16] B. Shieh-Beygi and S. Pietruszczak. Numerical analysis of structural masonry: mesoscale approach. Computers and Structures, 86:19581973, 2008.
  • [17] D. J. Sutcliff, H. S. Yu, and A. W. Page. Lower bound limit analysis of unreinforced masonry shear wall. Computers and Structures, 79:12951312, 2001.
  • [18] W. A. Thanoon, A. H. Alwathaf, J. Noorzaei, M. S. Jaafar, and M. R. Abdulkadir. Nonlinear finite element analysis of grouted and ungrouted hollow interlocking mortarless block masonry system. Engineering Structures, 30:15601572, 2008.
  • [19] A. T. Vermeltfoort, T. M. J. Raijmakers, and H. J. M. Janssen. Shear test on masonry walls. In Proc. 6th North Am. Masonry Conf., pages 11831193, Philadelphia, 1993.
  • *
    Author email:
  • Publication Dates

    • Publication in this collection
      17 Apr 2012
    • Date of issue
      2011

    History

    • Received
      25 Apr 2011
    • Accepted
      27 July 2011
    Individual owner www.lajss.org - São Paulo - SP - Brazil
    E-mail: lajsssecretary@gmsie.usp.br