Acessibilidade / Reportar erro

Degradation of orthodontic wires under simulated cariogenic and erosive conditions

Abstract

This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively) on the degradation of copper-nickel-titanium (CuNiTi) orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). CC and EC were simulated using a demineralizing solution (pH 4.3) and a citric acid solution (pH 2.3), respectively. Following treatment, the average surface roughness (Ra) of the wires was assessed, and friction between the wires and a passive self-ligating bracket was measured. CuNiTi wires subjected to ECs exhibited significantly higher Ra values than did those that were stored in artificial saliva. In contrast, surface roughness was not affected by CCs. Finally, friction between the treated wires and brackets was not affected by ECs or CCs. Our results indicate that CuNiTi orthodontic wires may suffer degradation within the oral cavity, as ECs increased the surface roughness of these wires. However, rougher surfaces did not increase friction between the wire and the passive self-ligating bracket.

Orthodontics; Corrosion; Friction


Introduction

Ongoing efforts to improve orthodontic technologies have led to the development of novel wire alloys, including copper-nickel-titanium (CuNiTi) wires. These wires are activated by the temperature within the oral cavity,11. Gurgel JA, Kerr S, Powers JM, LeCrone V. Force-deflection properties of superelastic nickel-titanium archwires. Am J Orthod Dentofacial Orthop. 2001 Oct;120(4):378-82. which produces beneficial memory effects. They also have greater elasticity, in contrast to conventional stainless steel wires, which must be frequently replaced during initial stages of alignment because of their low elastic recovery.22. Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop. 1989 Aug;96(2):100-9. These attributes of CuNiTi wires allow for the continuous transmission of force over a long period of time,11. Gurgel JA, Kerr S, Powers JM, LeCrone V. Force-deflection properties of superelastic nickel-titanium archwires. Am J Orthod Dentofacial Orthop. 2001 Oct;120(4):378-82.,33. Gil FJ, Planell JA. Effect of copper addition on the superelastic behavioron Ni-Ti shpe memory alloys or orthodontic applications.J Biomed Mater Res. 1999;48(5):682-8. increasing the time between wire-replacement procedures (10–12 weeks), as compared with stainless steel wires.44. Bennett RK. Extending treatment intervals. Clin Impressions. 2000;9(1):8-13.

The oral cavity is a complex environment, in which orthodontic appliances are subjected to chemical, thermal, and mechanical challenges.55. Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry. Eur J Orthod. 1998 Feb;20(1):79-92.,66. Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005 Apr;127(4):403-12.,77. Regis Júnior S, Soares P, Camargo ES, Guariza Filho O, Tanaka O, Maruo H. Biodegradation of orthodontic metallic brackets and associated implications for friction. Am J Orthod Dentofacial Orthop. 2011 Oct;140(4):501-9.Appliances typically remain in the oral cavity for prolonged periods of time, making a certain amount of degradation likely.77. Regis Júnior S, Soares P, Camargo ES, Guariza Filho O, Tanaka O, Maruo H. Biodegradation of orthodontic metallic brackets and associated implications for friction. Am J Orthod Dentofacial Orthop. 2011 Oct;140(4):501-9.,88. Daems J, Celis JP, Willems G. Morphological characterization of as-received and in vivo orthodontic stainless steel archwires. Eur J Orthod. 2009 Jun;31(3):260-5. Acids produced by intraoral bacteria99. Bahije L, Benyahia H, El Hamzaoui S, EbnTouhami M, Bengueddour R, Rerhrhaye W et al. Behavior of NiTi in the presence of oral bacteria: corrosion by Streptococcus mutans. Int Orthod. 2011 Mar;9(1):110-9. and from beverages1010. Parenti SI, Guicciardi S, Melandri C, Sprio S, Lafratta E, Tampieri A, et al. Effect of soft drinks on the physical and chemical features of nickel-titanium-based orthodontic wires. Acta Odontol Scand. 2012 Jan;70(1):49-55. can cause wire corrosion and affect the physical and mechanical properties of orthodontic wires.66. Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005 Apr;127(4):403-12.,99. Bahije L, Benyahia H, El Hamzaoui S, EbnTouhami M, Bengueddour R, Rerhrhaye W et al. Behavior of NiTi in the presence of oral bacteria: corrosion by Streptococcus mutans. Int Orthod. 2011 Mar;9(1):110-9. Moreover, corrosion increases the roughness of wire surfaces,66. Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005 Apr;127(4):403-12. which leads to wire-bracket friction and reduces the efficiency of orthodontic wires.55. Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry. Eur J Orthod. 1998 Feb;20(1):79-92.,66. Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005 Apr;127(4):403-12.,1111. Benyahia H, Ebn Touhami M, Forsal I, Zaoui F, Aalloula E. Corrosion resistance of NiTi in fluoride and acid environments. Int Orthod. 2009 Dec;7(4):322-34.,1212. Lee TH, Huang TK, Lin SY, Chen LK, Chou MY, Huang HH. Corrosion resistance of different nickel-titanium archwires in acidic fluoride-containing artificial saliva. Angle Orthod. 2010 May;80(3):547-53.

Here we exposed thermally activated orthodontic CuNiTi wires to cariogenic and erosive challenges (CCs and ECs, respectively) in vitro and then assessed wire surface roughness and the amount of friction between brackets and wires.

Methodology

This study was conducted using a randomized design with “storage condition” as the single experimental factor. Orthodontic wires (Damon Optimal Force Copper NiTi, Ormco, Glendora, USA) were measured with a digimatic caliper (Mitutoyo Sul Americana, São Paulo, Brazil) and cut into 30-mm segments using wire cutters. Sixty wire segments were divided into four groups (n = 15), which were exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). The analyzed response variables were surface roughness and friction.

Simulation of CCs and ECs

A demineralizing solution (pH 4.3) was used as the CC. This solution contained 2 mM calcium and 2 mM phosphate in 74 mM acetate buffer and is commonly used in dynamic physicochemical models of caries.1313. Featherstone JDB, O’Really MM, Shariatti M, Brugler S. Enhancement of remineralization in vitro and in vivo. In: Leach AS. Factors relating to demineralization and remineralization of teeth. Oxford: IRL; 1986. p. 23-34. The ingestion of cariogenic food typically lowers the pH of saliva and the biofilm microenvironment for ~45 min (pH < 5.5). As such, 6 h of immersion in the demineralizing solution corresponds to eight cariogenic challenges, which represent a highly cariogenic condition. To simulate 12 weeks of clinical use, i.e., the typical time that CuNiTi wires remain in the oral cavity, wire segments were individually immersed in 10 mL of demineralizing solution for 21 d (24 h per day), under 37 ± 1 °C.

A 0.05 M aqueous citric acid solution (pH 2.3) was used as the EC. This solution is commonly used as an extrinsic acid in laboratory models of dental erosion. With the assumption that contact between an acidic beverage and a dental structure is normally maintained for 90 sec, the experimental wires were individually immersed in 10 mL of the citric acid solution for 60 min each day for 21 d, under 37 ± 1 °C. This simulated 10 erosion episodes per day, which is considered a high EC.1414. Dugmore CR, Rock WP. A multifactorial analysis of factors associated with dental erosion. Br Dent J. 2004 Mar;196(5):283-6. During the remaining daily time (23 h), wires remained dry, under 37 ± 1 °C.

Wire segments exposed to artificial saliva were individually immersed in 10 mL of artificial saliva for 21 d (24 h per day), under 37 ± 1 °C. The artificial saliva, which mimics the inorganic components and rheological characteristics of natural human saliva, was described by McKnight-Hanes and Whitford1515. McKnight-Hanes C, Whitford GM. Fluoride release from three glass ionomer materials and the effects of varnishing with or without finishing. Caries Res. 1992;26(5):345-50. and modified by Amaechi et al.1616. Amaechi BT, Higham SM, Edgar WM. Techniques for the production of dental eroded lesions in vitro. J Oral Rehabil. 1999 Feb;26(2):97-102. It was composed of sodium hydroxymethyl benzoate, sodium carboxymethylcellulose, KCl, MgCl2·6H2O, CaCl2·2H2O, K2HPO4, and KH2PO4.1515. McKnight-Hanes C, Whitford GM. Fluoride release from three glass ionomer materials and the effects of varnishing with or without finishing. Caries Res. 1992;26(5):345-50.,1616. Amaechi BT, Higham SM, Edgar WM. Techniques for the production of dental eroded lesions in vitro. J Oral Rehabil. 1999 Feb;26(2):97-102. Wires within the control group were untreated, i.e., they were stored dry, under 37 ± 1 °C.

Surface roughness assessment

Each orthodontic wire segment was gently dabbed dry with absorbent paper, and a surface roughness tester (TR200, Time Group, Beijing, China) was used to take five readings of surface roughness. The cut-off value was 0.25 mm to filter surface waviness. The surface roughness was the arithmetical average value of all absolute distances of the roughness profile from the center line within the measuring length (Ra, mm). The surface roughness for each orthodontic wire was the average of the five readings.

Friction testing

Each wire segment was positioned within a friction testing apparatus, which was mounted on the transverse beam of a universal testing machine (EMIC DL 10000, São José dos Pinhais, Brazil) equipped with a 20-N load cell. The wire segments were positioned parallel to the base of a passive self-ligating bracket (Damon 3 MX, 0.022 × 0.027–inch slot; Ormco, Glendora, USA), which was bonded to the base of the device with a cyanoacrylate adhesive (Loctite Super Bonder Original, Henkel, Itapevi, Brazil).

During testing, mucin-based artificial saliva (50 µL) was used to simulate natural human saliva. The artificial saliva contained mucin, xylitol, methylparaben, EDTA, benzalkonium chloride, and NaF in an aqueous solution, as described.1717. Christersson CE, Lindh L, Arnebrant T. Film-forming properties and viscosities of saliva substitutes and human whole saliva. Eur J Oral Sci. 2000 Oct;108(5):418-25. The force required to move the wire segment 1 mm at a crosshead speed of 3 mm/min was recorded. The test was performed eight times for each wire-bracket set. For each wire segment, a new self-ligating bracket was used.

Atomic force microscopy (AFM)

To obtain topographical information about surface roughness, representative wire segments were imaged using AFM (NanoScope V platform, Bruker, Santa Barbara, USA). Measurements were performed in tapping mode.

Statistical analysis

Data concerning surface roughness and friction were analyzed using the non-parametric Kruskal-Wallis test. Post hoc pairwise comparisons were then made with Dunn’s test. Spearman’s test was applied to verify correlations between surface roughness and friction. Statistical analyses were performed using SPSS software, version 20 (SPSS, Chicago, USA). Significance level was set at 5%.

Results

The storage condition significantly affected surface roughness of CuNiTi orthodontic wires (p = 0.004, Table). Wires exposed to the ECs were significantly rougher than wires stored in artificial saliva. Artificial saliva did not affect roughness, as this group was not different from the untreated group. Wires exposed to CCs exhibited intermediate values of roughness, which were not significantly different from roughness values associated with artificial-saliva or EC groups. Friction between the CuNiTi orthodontic wires and the self-ligating brackets was not affected by the storage condition (p = 0.430). Finally, there was no correlation between Ra values and wire-bracket friction (p = 0.376; r22. Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop. 1989 Aug;96(2):100-9. = 0.116).

Table
Surface roughness and friction values for CuNiTi wires.

Discussion

Wires exposed to the EC had significantly higher surface roughness compared with wires exposed to artificial saliva or untreated wires. This result was substantiated by AFM images, which revealed deep valleys in the wire subjected to the ECs (Figure 1d). However, the untreated group also exhibited small surface irregularities (Figure 1a), which likely resulted from the wire manufacturing process.1818. Bentahar Z, Bellamine M, Zertoubi M, Irhzo A, El Boussiri K. Relationship between electrochemical corrosion and the tribologic properties of orthodontic alloys. Int Orthod. 2010 Dec;8(4):360-71.

Figure 1
AFM images of orthodontic wires from untreated (a), artificial-saliva (b), CC (c), and EC (d) groups.

The immersion of thermally activated NiTi wires in orange juice, soft drinks, or sports drinks does not affect wire topography.1010. Parenti SI, Guicciardi S, Melandri C, Sprio S, Lafratta E, Tampieri A, et al. Effect of soft drinks on the physical and chemical features of nickel-titanium-based orthodontic wires. Acta Odontol Scand. 2012 Jan;70(1):49-55. However, immersion times used in this previous study were ~95% shorter than immersion times used in our current study. We based our immersion times on previous simulations of diet-induced acid erosion1919. Attin T, Knöfel S, Buchalla W, Tütüncü R. In situ evaluation of different remineralization periods to decrease brushing abrasion of demineralized enamel. Caries res. 2001 May-Jun;35(3):216-22.,2020. Hara AT, Turssi CP, Teixeira ECN, Serra MC, Cury JA. Abrasive wear on eroded root dentine after different periods of exposure to saliva in situ. Eur J Oral Sci. 2003 Oct;111(5):423-7. and on the amount of time that CuNiTi wires remain in the oral cavity. It is worth mentioning that the recovery of salivary pH following the intake of acidic food typically takes 2 min for anterior teeth and 5-15 min for posterior teeth.2121. Millward A, Shaw L, Harrington E, Smith AJ. Continuous monitoring of salivary flow rate and pH at the surface of the dentition following consumption of acidic beverages. Caries Res. 1997;31(1):44-9.,2222. Lussi A, Von Salis-Marincek M, Ganss C, Hellwig E, Cheaib Z, Jaeggi T. Clinical study monitoring the pH on tooth surfaces in patients with and without erosion. Caries Res. 2012;46(6):507-12. Consequently, the effect of ECs on orthodontic wires may be exacerbated. Under clinical conditions, however, the clearing, diluting, and buffering properties of saliva likely help to minimize the deleterious effects of erosive acids.

The CC used in this study simulated situations in which CuNiTi wire comes in contact with bacterial acids. We chose a demineralizing solution that is frequently used in dynamic physicochemical models of caries.2323. Serra MC, Cury JA. The in vitro effect of glass-ionomer cement restoration on enamel subjected to a demineralization and remineralization model. Quintessence Int. 1992 Feb;23(2):143-7.,2424. Basting RT, Rodrigues Júnior AL, Serra MC. The effect of 10% carbamide peroxide bleaching material on microhardness of sound and demineralized enamel and dentin in situ. Oper Dent. 2001 Nov-Dec;26(6):531-9.,2525. Turssi CP, Magalhães CS, Serra MC, Rodrigues Júnior AL. Surface roughness assessment of resin-based materials during brushing preceded by pH-cycling simulations. Oper Dent. 2001 Nov-Dec;26(6):576-84.,2626. Rodrigues JA, Marchi GM, Serra MC, Hara AT. Visual evaluation of in vitro cariostatic effect of restorative materials associated with dentifrices. Braz Dent J. 2005;16(2):112-8. Wires exposed to CCs had intermediate levels of surface roughness, which were not significantly different from roughness measured for the artificial-saliva or EC groups (Figure 1c). This may be because the demineralizing solution had an intermediate pH of 4.3 in relation citric acid solution and artificial saliva. The lack of a significant difference between the surface roughness of the CC and artificial saliva groups contradicts Bahije et al.,99. Bahije L, Benyahia H, El Hamzaoui S, EbnTouhami M, Bengueddour R, Rerhrhaye W et al. Behavior of NiTi in the presence of oral bacteria: corrosion by Streptococcus mutans. Int Orthod. 2011 Mar;9(1):110-9. who reported that NiTi wires immersed in artificial saliva with Streptococcus mutans showed more corrosion than controls. This discrepancy may reflect differences between the microbiological model and the physicochemical model that was used in the current study. In addition, Bahije et al.99. Bahije L, Benyahia H, El Hamzaoui S, EbnTouhami M, Bengueddour R, Rerhrhaye W et al. Behavior of NiTi in the presence of oral bacteria: corrosion by Streptococcus mutans. Int Orthod. 2011 Mar;9(1):110-9. used an electrochemical approach (rather than surface roughness) to assess the effects of the tested solutions.

CuNiTi wires immersed in artificial saliva had mineral micro-deposits on their surface, as shown by AFM (Figure 1b). Such deposits, which are likely formed by calcium and phosphate, are consistent with previous observations2727. Huang HH. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity. J Biomed Mater R. 2005 Sep;74(4):629-39. and result from mineral precipitation, which is expected under laboratory conditions.

Although CuNiTi wire exposed to the EC exhibited corrosive degradation and elevated Ra values, this did not increase the friction between the wire and the self-ligating bracket, i.e., there was not a significant correlation between surface roughness and friction. Therefore, despite wire degradation, sliding of the wire in the bracket slot was not impaired. Thus, the surface roughness of an orthodontic wire cannot predict its friction.55. Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry. Eur J Orthod. 1998 Feb;20(1):79-92. Previous studies, however, have reported associations between surface roughness and friction,66. Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005 Apr;127(4):403-12.,2828. Read-Ward GE, Jones SP, Davies EH. A comparison of self-ligating and conventional orthodontic bracket systems. Br J Orthod.1997 Nov;24(4):309-17.,2929. Fischer-Brandies H, Es-Souni M, Kock N, Raetzke K, Bock O. Transformation behaviour, chemical composition, surface topography and bending properties of five selected 0.016’’ x 0.022’’ NiTi archwires. J Orofac Orthop. 2003 Mar;64(2):88-99. indicating that additional studies are required to clarify the influence of surface roughness on orthodontic-wire friction.

One factor that may explain the lack of correlation between surface roughness and friction was the use of a mucin-based artificial saliva during the friction test. This type of artificial saliva simulates the rheological properties of natural human saliva.1717. Christersson CE, Lindh L, Arnebrant T. Film-forming properties and viscosities of saliva substitutes and human whole saliva. Eur J Oral Sci. 2000 Oct;108(5):418-25. It is possible that if the treated wires had been tested under dry conditions an association between surface roughness and friction would have been revealed. In addition, the friction tests were performed using a passive self-ligating bracket, which produces less friction during sliding and may have influenced the results. Further research is needed to clarify whether other types of brackets, such as active self-ligating brackets, would yield similar results.

Conclusions

CuNiTi orthodontic wires may suffer degradation in the oral cavity, as ECs increased the surface roughness of these wires. However, the rougher surface did not increase friction between the wire and the passive self-ligating bracket.

Acknowledgments

The authors wish to thank Tatiana Ricci for her technical assistance with the friction testing.

References

  • 1
    Gurgel JA, Kerr S, Powers JM, LeCrone V. Force-deflection properties of superelastic nickel-titanium archwires. Am J Orthod Dentofacial Orthop. 2001 Oct;120(4):378-82.
  • 2
    Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop. 1989 Aug;96(2):100-9.
  • 3
    Gil FJ, Planell JA. Effect of copper addition on the superelastic behavioron Ni-Ti shpe memory alloys or orthodontic applications.J Biomed Mater Res. 1999;48(5):682-8.
  • 4
    Bennett RK. Extending treatment intervals. Clin Impressions. 2000;9(1):8-13.
  • 5
    Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry. Eur J Orthod. 1998 Feb;20(1):79-92.
  • 6
    Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005 Apr;127(4):403-12.
  • 7
    Regis Júnior S, Soares P, Camargo ES, Guariza Filho O, Tanaka O, Maruo H. Biodegradation of orthodontic metallic brackets and associated implications for friction. Am J Orthod Dentofacial Orthop. 2011 Oct;140(4):501-9.
  • 8
    Daems J, Celis JP, Willems G. Morphological characterization of as-received and in vivo orthodontic stainless steel archwires. Eur J Orthod. 2009 Jun;31(3):260-5.
  • 9
    Bahije L, Benyahia H, El Hamzaoui S, EbnTouhami M, Bengueddour R, Rerhrhaye W et al. Behavior of NiTi in the presence of oral bacteria: corrosion by Streptococcus mutans. Int Orthod. 2011 Mar;9(1):110-9.
  • 10
    Parenti SI, Guicciardi S, Melandri C, Sprio S, Lafratta E, Tampieri A, et al. Effect of soft drinks on the physical and chemical features of nickel-titanium-based orthodontic wires. Acta Odontol Scand. 2012 Jan;70(1):49-55.
  • 11
    Benyahia H, Ebn Touhami M, Forsal I, Zaoui F, Aalloula E. Corrosion resistance of NiTi in fluoride and acid environments. Int Orthod. 2009 Dec;7(4):322-34.
  • 12
    Lee TH, Huang TK, Lin SY, Chen LK, Chou MY, Huang HH. Corrosion resistance of different nickel-titanium archwires in acidic fluoride-containing artificial saliva. Angle Orthod. 2010 May;80(3):547-53.
  • 13
    Featherstone JDB, O’Really MM, Shariatti M, Brugler S. Enhancement of remineralization in vitro and in vivo. In: Leach AS. Factors relating to demineralization and remineralization of teeth. Oxford: IRL; 1986. p. 23-34.
  • 14
    Dugmore CR, Rock WP. A multifactorial analysis of factors associated with dental erosion. Br Dent J. 2004 Mar;196(5):283-6.
  • 15
    McKnight-Hanes C, Whitford GM. Fluoride release from three glass ionomer materials and the effects of varnishing with or without finishing. Caries Res. 1992;26(5):345-50.
  • 16
    Amaechi BT, Higham SM, Edgar WM. Techniques for the production of dental eroded lesions in vitro. J Oral Rehabil. 1999 Feb;26(2):97-102.
  • 17
    Christersson CE, Lindh L, Arnebrant T. Film-forming properties and viscosities of saliva substitutes and human whole saliva. Eur J Oral Sci. 2000 Oct;108(5):418-25.
  • 18
    Bentahar Z, Bellamine M, Zertoubi M, Irhzo A, El Boussiri K. Relationship between electrochemical corrosion and the tribologic properties of orthodontic alloys. Int Orthod. 2010 Dec;8(4):360-71.
  • 19
    Attin T, Knöfel S, Buchalla W, Tütüncü R. In situ evaluation of different remineralization periods to decrease brushing abrasion of demineralized enamel. Caries res. 2001 May-Jun;35(3):216-22.
  • 20
    Hara AT, Turssi CP, Teixeira ECN, Serra MC, Cury JA. Abrasive wear on eroded root dentine after different periods of exposure to saliva in situ. Eur J Oral Sci. 2003 Oct;111(5):423-7.
  • 21
    Millward A, Shaw L, Harrington E, Smith AJ. Continuous monitoring of salivary flow rate and pH at the surface of the dentition following consumption of acidic beverages. Caries Res. 1997;31(1):44-9.
  • 22
    Lussi A, Von Salis-Marincek M, Ganss C, Hellwig E, Cheaib Z, Jaeggi T. Clinical study monitoring the pH on tooth surfaces in patients with and without erosion. Caries Res. 2012;46(6):507-12.
  • 23
    Serra MC, Cury JA. The in vitro effect of glass-ionomer cement restoration on enamel subjected to a demineralization and remineralization model. Quintessence Int. 1992 Feb;23(2):143-7.
  • 24
    Basting RT, Rodrigues Júnior AL, Serra MC. The effect of 10% carbamide peroxide bleaching material on microhardness of sound and demineralized enamel and dentin in situ. Oper Dent. 2001 Nov-Dec;26(6):531-9.
  • 25
    Turssi CP, Magalhães CS, Serra MC, Rodrigues Júnior AL. Surface roughness assessment of resin-based materials during brushing preceded by pH-cycling simulations. Oper Dent. 2001 Nov-Dec;26(6):576-84.
  • 26
    Rodrigues JA, Marchi GM, Serra MC, Hara AT. Visual evaluation of in vitro cariostatic effect of restorative materials associated with dentifrices. Braz Dent J. 2005;16(2):112-8.
  • 27
    Huang HH. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity. J Biomed Mater R. 2005 Sep;74(4):629-39.
  • 28
    Read-Ward GE, Jones SP, Davies EH. A comparison of self-ligating and conventional orthodontic bracket systems. Br J Orthod.1997 Nov;24(4):309-17.
  • 29
    Fischer-Brandies H, Es-Souni M, Kock N, Raetzke K, Bock O. Transformation behaviour, chemical composition, surface topography and bending properties of five selected 0.016’’ x 0.022’’ NiTi archwires. J Orofac Orthop. 2003 Mar;64(2):88-99.

Publication Dates

  • Publication in this collection
    2014

History

  • Received
    26 Sept 2013
  • Accepted
    25 Feb 2014
  • rev-request
    30 May 2014
Sociedade Brasileira de Pesquisa Odontológica - SBPqO Av. Prof. Lineu Prestes, 2227, 05508-000 São Paulo SP - Brazil, Tel. (55 11) 3044-2393/(55 11) 9-7557-1244 - São Paulo - SP - Brazil
E-mail: office.bor@ingroup.srv.br