Acessibilidade / Reportar erro

Physicomechanical characterization and biological evaluation of bulk-fill composite resin

Abstract

The aim of this study was to evaluate the cytotoxic effect, degree of conversion (% DC), Vickers hardness (VH), and surface morphology of composite resins. Eleven resins, nine bulk-fill resins, and two conventional resins were evaluated. Each material was sampled to evaluate DC (using FTIR), VH, cytotoxicity (using MTT and Neutral Red - NR test), surface morphology (using SEM and AFM), and organic filler (using EDS). All statistical tests were performed with SPSS and the level of significance was set at 0.05. MTT revealed that the materials presented low or no cytotoxic potential in relation to the control. Opus was the resin with the lowest cell viability at a 1:2 concentration at 72 h (32%) and at 7 days (43%), but that significantly increased when the NR test was applied at a 1:2 concentration after 7 days. Thickness and surface subjected to polymerization had no influence on DC, and differences were observed only between the materials. In the microhardness test, statistical differences were observed between the evaluated thicknesses. The bulk-fill resins analyzed in this study exhibited low and/or no cytotoxicity to L929 cells, except for Opus, which showed moderate cytotoxicity according to the MTT assay. When the NR test was used, results were not satisfactory for all composites, indicating the need for different methodologies to evaluate the properties of these materials. The assessed resins demonstrated acceptable physicomechanical properties.

Composite Resins; Biocompatible Materials; In Vitro Techniques

Introduction

The use of composite resins in restorative procedures has increased over the years, especially because of their aesthetic properties. However, there is still considerable concern about polymerization shrinkage, degree of conversion, and biocompatibility/cytotoxicity. 11. Moharamzadeh K, Brook IM, Scutt AM, Thornhill MH, Van Noort R. Mucotoxicity of dental composite resins on a tissue-engineered human oral mucosal model. J Dent. 2008 May;36(5):331-6. https://doi.org/10.1016/j.jdent.2008.01.019
https://doi.org/10.1016/j.jdent.2008.01....
The cytotoxicity of these materials has been associated with the quantity and type of residual monomer released, and studies have shown a correlation between this phenomenon and mass loss and/or low degree of conversion. 22. Salehi S, Gwinner F, Mitchell JC, Pfeifer C, Ferracane JL. Cytotoxicity of resin composites containing bioactive glass fillers. Dent Mater. 2015 Feb;31(2):195-203. https://doi.org/10.1016/j.dental.2014.12.004
https://doi.org/10.1016/j.dental.2014.12...
Although composite resins are biologically accepted, there has been evidence of allergic effects on oral mucosal tissues, 33. Sevkusic M, Schuster L, Rothmund L, Dettinger K, Maier M, Hickel R et al. The elution and breakdown behavior of constituents from various light-cured composites. Dent Mater. 2014 Jun;30(6):619-31. https://doi.org/10.1016/j.dental.2014.02.022
https://doi.org/10.1016/j.dental.2014.02...
due to the dissolution of methacrylate and leaching of its components, 44. Darmani H, Al-Hiyasat AS, Milhem MM. Cytotoxicity of dental composites and their leached components. Quintessence Int. 2007 Oct;38(9):789-95. resulting from masticatory forces and chemical degradation. 55. Tauböck TT, Marovic D, Zeljezic D, Steingruber AD, Attin T, Tarle Z. Genotoxic potential of dental bulk-fill resin composites. Dent Mater. 2017 Jul;33(7):788-95. https://doi.org/10.1016/j.dental.2017.04.011
https://doi.org/10.1016/j.dental.2017.04...

Thus, composite resins, known as bulk-fill resins, with modifications in their chemical formulation and polymerization properties, have been developed to minimize or eliminate polymerization shrinkage, increasing the depth of polymerization as well as cytotoxicity. Bulk-fill resins with a 4–6 mm single increment have low shrinkage stress and a high degree of polymerization at this depth, due in particular to the increase in translucency and to the presence of polymerization modulators. 66. Marovic D, Tauböck TT, Attin T, Panduric V, Tarle Z. Monomer conversion and shrinkage force kinetics of low-viscosity bulk-fill resin composites. Acta Odontol Scand. 2015 Aug;73(6):474-80. https://doi.org/10.3109/00016357.2014.992810
https://doi.org/10.3109/00016357.2014.99...
,77. Benetti AR, Havndrup-Pedersen C, Honoré D, Pedersen MK, Pallesen U. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation. Oper Dent. 2015 Mar-Apr;40(2):190-200. https://doi.org/10.2341/13-324-L
https://doi.org/10.2341/13-324-L...
However, what is not clear is whether the degree of conversion at this depth is compromised, which would increase the cytotoxic potential, especially in the case of bulk-fill flowable resins with a higher organic matter content. 88. Furness A, Tadros MY, Looney SW, Rueggeberg FA. Effect of bulk/incremental fill on internal gap formation of bulk-fill composites. J Dent. 2014 Apr;42(4):439-49. https://doi.org/10.1016/j.jdent.2014.01.005
https://doi.org/10.1016/j.jdent.2014.01....
,99. Jan YD, Lee BS, Lin CP, Tseng WY. Biocompatibility and cytotoxicity of two novel low-shrinkage dental resin matrices. J Formos Med Assoc. 2014 Jun;113(6):349-55. https://doi.org/10.1016/j.jfma.2012.07.008
https://doi.org/10.1016/j.jfma.2012.07.0...
Therefore, given the difficulties of in vivo studies, this in vitro study investigated the degree of conversion, microhardness, surface morphology, and cytotoxicity of newly developed composites. Three hypotheses were tested: the differences in time and concentration of the assessed composite resin samples would not make them potentially cytotoxic to cells. There would be no difference between the methods used for evaluating cytotoxicity. The degree of conversion and microhardness would not be dependent on material thickness or on the surface subjected to polymerization.

Methodology

Sample preparation

Nine bulk-fill resins – Aura Bulk Fill (SDI, Australia), Filtek Bulk Fill Flow (3MESPE, Germany), Filtek Bulk Fill Sculptable (3MESPE, Germany), Surefil SDR+ (Dentsply, Germany), Tetric EvoFlow Bulk Fill (Ivoclar-Vivadent, Liechtenstein), Admira Fusion (Voco, Germany) X-tra Fil (Voco, Germany), X-tra Base (Voco, Germany), Opus (FGM, Brazil); and two conventional resins – Filtek Z350XT (3MESPE, Germany) and Filtek Z350 Flow (3MESPE, Germany), were evaluated ( Table 1 ).

Table 1
Materials used in the study (Information provided by manufacturers).

Samples of each material with 5 mm in diameter and 2 mm and 4 mm in thickness were prepared for assessment of degree of conversion and Vickers hardness. In order to avoid inhibition of oxygen, a transparent polyester strip was placed on the top and bottom of the mold, and resins were inserted and photopolymerized with a LED device (KaVo Poly Wireless, KaVo - Brazil) according to the manufacturer’s instructions ( Table 1 ). All specimens were stored in distilled water for 24 h at 37°C prior to testing. For the cytotoxicity test, discs of each material (5 x 4 mm, n = 2) were prepared under aseptic conditions, using sterile material and a laminar flow cabinet, to reduce any risk of biological contamination of the cells. Thereafter, the samples were placed in 24-well plates with 200 µL of culture medium (RPMI -1640) at two different time intervals (72 h and 7 days) at 37ºC and 5% CO2, to obtain the extracts.

Cell culture and cytotoxicity assay (MTT assay)

The fibroblast cell line was obtained from ATCC (ATCC® L929), and cells were grown in RPMI 1640 medium containing L-glutamine, sodium pyruvate, and 2.0 g/L of NaHCO3 supplemented with 10% fetal bovine serum (FBS), and 1% penicillin-streptomycin (Gibco® Anti-anti (100X), USA) at 37 °C and 5% CO2. Cell density was evaluated and cells were exposed to 2 mL of trypsin solution (0.25%) - Sigma-Aldrich (Sigma Chemical Co., St. Louis, MO, USA) for 5 min, neutralized with the same amount of culture medium, and cell viability was then assessed. Subsequently the cells were seeded in 96-well plates (TPP, Darmstadt, Germany) at the concentration of 1 x 105 cells/mL per well, each containing 100 µL of medium, for 24 h at 37ºC and 5% CO2. After that, the medium was removed and replaced with the extracts of the diluted resin to obtain 1:2 and 1:10 concentrations. The negative control consisted of cells treated with culture medium only. Cell metabolism was evaluated by the MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide)) assay, in accordance with the BS EN ISO 10993-5 1010. International Organization for Standardization – ISO. ISO 10993-5:2009: Biological evaluation of medical devices. Part 5: Tests for in vitro cytotoxicity. Geneve: International Organization for Standardization; 2009. standard, and absorbance was measured at 570 nm and 650 nm using a spectrophotometer (PerkinElmer VICTORTM X3). Grubbs’ test was used to eliminate outliers, and cell viability was estimated considering the negative control at 100%.

Neutral red incorporation

L929 cells were seeded in 96-well plates at the concentration of 1 x 105 cells/well using Dulbecco’s modified Eagle’s medium (DMEM) without phenol red and kept in an oven with 5% CO2 at 37 °C for 24 h. Thereafter, the medium was removed and added to the medium with the extracts (1:2 and 1:10 concentrations), and incubated again for 24 h at 37 ºC and 5% CO2. The supernatant of the media with the extracts was discarded, and 100 µL of neutral red (50 µg/mL, Sigma Aldrich, USA), previously incubated for 12 h, was added. After allowing some time for the cells to take up the neutral red, the medium was removed and cells were washed twice with PBS – Dulbecco for eliminating excessive extracellular dye and photographing cell condition. Then, a lysis solution (1% acetic acid and 49% absolute ethanol) was added in order to extract the neutral red incorporated into lysosomes. The plate was stirred for 30 min and absorbance was measured at 540 nm with a spectrophotometer (PerkinElmer VICTORTM X3). Grubbs’ test was used to eliminate the outliers, and cell viability was estimated considering the negative control at 100%.

Degree of conversion (% DC)

The unpolymerized material and the top and bottom surfaces of the photopolymerized samples were analyzed by FTIR using a spectrophotometer (Perkin Elmer, Norwalk, USA) equipped with attenuated total reflection (ATR), at 4,000-650 nm. Thirty-two scans were taken of each sample (n = 3) with a resolution of 2.0 cm-1. Peak heights at 1,637 cm-1 (aliphatic carbon-carbon bonds) and at 1,608 cm-1 (aromatic carbon-carbon bonds) were measured using the normalized baseline method, on the same equipment, and the % DC values of the monomers were determined by the following equation:

% DC = [ 1 - 1637 cm - 1 1608 cm - 1 Peak height cured 1637 cm - 1 1608 cm - 1 Peak height uncured ] x 100

Vickers hardness (VH)

Vickers hardness test was performed with a digital microdurometer (FM 700, Future Tech Corp., Equilam, Tokyo, Japan), with a 50-kg load applied for 15 s. Three readings were taken from the top and bottom of the test specimens (2 mm and 4 mm), and a final mean was obtained for each sample (n = 5). The length of the diagonals (d 1 and d 2), left in the specimens by the penetrator, was digitally measured by a light microscope coupled to the microdurometer.

Surface morphology analysis (SEM and AFM) and identification of chemical elements (EDS)

For the surface morphology analysis, a sample of each material was subjected to finishing and polishing procedures, performed in a single direction, for 15 s, with Sof-Lex discs (high, medium, fine, and ultrafine, respectively), according to the manufacturer’s instructions. A new disc was used for each sample. The specimens were cleaned in an ultrasonic tank for 5 min at 50ºC and then washed with distilled water and dried at room temperature (30 min). Afterwards, the samples were examined by low vacuum scanning electron microscopy – SEM (PHENOM pro X, ANACOM Scientific) with detector operating at 15Kv. Images from a representative area of the surfaces of the composite resins were obtained at 500X and 3,000X magnification. In addition, energy dispersive X-ray spectroscopy (EDS) was performed to determine the chemical elements present at the point of the incident beam. Three areas of each sample were selected for EDS reading.

Atomic force microscopy (AFM) was performed in one sample of each material using a commercial AFM (Veeco Metrology Group, Santa Barbara, CA, USA) in contact mode (cantilevers) with a spring constant of 0.1 N/m and OTR 8-35 Nanoprobe SPM tips. Images (30 × 30 μm) were obtained with a resolution of 512 x 512 pixels and analyzed using dedicated software (Nanoscope v616r1, Veeco Metrology Group and WSxM 4.0 Develop 11.1, Nanotec Electronica, TreaCantas, Spain).

Data analysis

Data were analyzed descriptively (mean and standard deviation), inferentially (paired Student’s t or Wilcoxon tests), and by the F statistic (ANOVA) with Tukey’s post-hoc or Tamhane’s tests. The paired Student’s t test, Wilcoxon test for paired data, F statistic (ANOVA) with Tamhane’s multiple comparisons or with Tukey’s multiple comparisons were used in the MTT assay. The paired Student’s t test, Wilcoxon test for paired data, and F statistic (ANOVA) with multiple comparisons were used for assessing neutral red uptake. Finally, Wilcoxon test for paired data, the Kruskal-Wallis test with paired comparisons and the Mann-Whitney test were used for the analysis of microhardness and degree of conversion. All the tests were performed using SPSS version 23, and the level of significance was set at 0.05.

Results

Cytotoxic effect assessed by the MTT Assay

Table 2 presents the mean, standard deviation, and coefficient of variation of the evaluated materials for their cytotoxic potential. The materials showed variable responses to cell metabolism. Low and/or no cytotoxic effect was observed for some of the tested resins in relation to time of evaluation and concentration of the extracts (1:2 and 1:10). Only Opus resin showed moderate cytotoxicity after 7 days at the 1:2 concentration. At 72 h, all resins reduced the percentage of cell viability, except for Z350 and Z350F, when the concentration of the extracts was accounted for.

Table 2
Mean ± standard deviation of MTT according to material, concentration, and days of evaluation.

Neutral red incorporation

Table 3 presents the results for the neutral red incorporation test. After 7 days of evaluation, Opus, FBFS, FBFF, and ABF showed a lower percentage (92%, 80%, 76%, and 54%, respectively) of cell viability at the 1:2 concentration.

Table 3
Mean ± standard deviation of neutral red according to material, concentration and days of evaluation.

Table 4 shows the statistical difference between extract concentrations according to each method of cytotoxicity analysis. The MTT assay revealed that only Opus, Z350 and XTF resins showed statistical differences between the extracts after 72 h, without any difference verified for Z350 and XTF after 7 days. The neutral red test indicated statistically significant differences among most resins when the concentrations of the extracts were compared, especially after 7 days.

Table 4
Statistical analysis of cytotoxicity of the materials with comparison of extract concentrations, according to each test.

Degree of conversion

Table 5 shows the percentage degree of conversion according to thickness (2 mm and 4 mm) and the analysis of surface morphology (top and bottom). The resins presented no significant difference in degree of conversion at 2 mm and 4 mm. Statistically significant differences were observed only between materials.

Table 5
Mean ± standard deviation of degree of conversion according to material and thickness, and the surface of the test specimen subjected to polymerization.

Vickers hardness

Microhardness values are listed in Table 6 . The lowest microhardness values were observed for FBFF, Opus, and TEF resins, while the highest ones were obtained for XTF and Z350. No statistical difference was observed regarding the surface subjected to polymerization, but statistically significant differences were found when the thickness of the test specimens was compared.

Table 6
Mean ± standard deviation of microhardness according to material, thickness, and surface of the test specimen subjected to polymerization.

Surface morphology (SEM/AFM) and EDS analyses

SEM images showed surfaces with deep scratches, detachment, and protrusion of load particles. The AFM analysis revealed depressions, protrusions, and irregular surfaces with deep scratches in most resins. TEF, Opus, and XTF resins presented uniform and slightly scratched surfaces with homogeneous surface topography ( Figure ).

Figure 1
Image representative of the surface morphology (SEM/AFM) of the materials after finishing and polishing with soft-lex discs. SEM images at 500 and 3000X magnification.

Table 7 presents the chemical composition and the respective percentages of inorganic components for the resins evaluated by EDS. Most resins contained Si, followed by Ba, Zr, and Al. Zirconia and silica peaks corresponded to the zirconia-silica clusters or to the silicate particles found in the composite resins. Ba could represent the barium-silicate particles added to ensure radiopacity.

Table 7
Chemical elements identified by means of EDS analysis (% and SD).

Discussion

The results of this study led to the rejection of the first null hypothesis. In the MTT assay, there was a greater decrease in cell viability at the 1:2 than at the 1:10 concentration, and the materials showed a slight cytotoxic potential in relation to the control, except for Opus (1:2 – 72 h). 1111. Toh WS, Yap AU, Lim SY. In vitro biocompatibility of contemporary bulkfill composites. Oper Dent. 2015 Nov-Dec;40(6):644-52. https://doi.org/10.2341/15-059-L
https://doi.org/10.2341/15-059-L...
Low cytotoxicity levels detected by MTT in pulp cells were also reported by Marigo et al. 1212. Marigo L, Spagnuolo G, Malara F, Martorana GE, Cordaro M, Lupi A et al. Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites. Eur Rev Med Pharmacol Sci. 2015 Dec;19(23):4469-80.

The cytotoxicity of these materials has been associated with the amount and type of residual monomer released, demonstrating a correlation between this phenomenon and mass loss and/or low degree of conversion. 1313. Ahmed RH, Aref MI, Hassan RM, Mohammed NR. Cytotoxic effect of composite resin and amalgam filling materials on human labial and buccal epithelium. Nat Sci. 2010;8(10):48-53. Even though composite resins are considered to be biologically well tolerated, there have been some reports of allergic effects on oral mucosal tissues, 33. Sevkusic M, Schuster L, Rothmund L, Dettinger K, Maier M, Hickel R et al. The elution and breakdown behavior of constituents from various light-cured composites. Dent Mater. 2014 Jun;30(6):619-31. https://doi.org/10.1016/j.dental.2014.02.022
https://doi.org/10.1016/j.dental.2014.02...
due to the dissolution of methacrylate and to the leaching of its components. 44. Darmani H, Al-Hiyasat AS, Milhem MM. Cytotoxicity of dental composites and their leached components. Quintessence Int. 2007 Oct;38(9):789-95. All the materials presented acceptable cytotoxic potential at the thickness of 4 mm; however, Opus did not fit into these standards, corroborating the results of Jang et al., 1414. Jang JH, Park SH, Hwang IN. Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin. Oper Dent. 2015 Mar-Apr;40(2):172-80. https://doi.org/10.2341/13-307-L
https://doi.org/10.2341/13-307-L...
who affirmed that not all bulk-fill resins achieve proper polymerization at this thickness. According to the neutral red test, cell viability decreased as exposure time increased from 72 h to 7 days, especially for the bulk-fill flowable resins, except for TEF. This indicates that the components of the resins are continuously released after polymerization, corroborating the findings of Karaarslan et al. 1515. Karaarslan ES, Altintas S, Bulbul M, Cebe MA, Usumez A. High performance liquid chromatography analysis of monomers from one composite resin cured with different polymerization methods. Mater Res Innov. 2011 Nov;15(2):124-9. https://doi.org/10.1179/143307511X12998222918912
https://doi.org/10.1179/143307511X129982...
On the other hand, Yildirin-Bicer et al. 1616. Yildirim-Bicer AZ, Ergun G, Egilmez F, Demirkoprulu H. In vitro cytotoxicity of indirect composite resins: effect of storing in artificial saliva. Indian J Dent Res. 2013 Jan-Feb;24(1):81-6. https://doi.org/10.4103/0970-9290.114962
https://doi.org/10.4103/0970-9290.114962...
reported that the 24-hour exposure period proved to be the most cytotoxic one. Tsitrou et al., 1717. Tsitrou E, Kelogrigoris S, Koulaouzidou E, Antoniades-Halvatjoglou M, Koliniotou-Koumpia E, van Noort R. Effect of extraction media and storage time on the elution of monomers from four contemporary resin composite materials. Toxicol Int. 2014 Jan;21(1):89-95. https://doi.org/10.4103/0971-6580.128811
https://doi.org/10.4103/0971-6580.128811...
however, reported that the time, solution, and type of material used significantly influence the detection of residual monomer and cytotoxicity. 1818. Ak AT, Alpoz AR, Bayraktar O, Ertugrul F. Monomer release from resin based dental materials cured with LED and halogen lights. Eur J Dent. 2010 Jan;4(1):34-40. In this study, an aqueous medium was used by means of the direct technique, which may have favored the dissolution of hydrophilic and low molecular weight monomers.

The release of monomers, especially methacrylate-based ones (Bis-GMA, Bis-EMA, UDMA), co-monomers (TEGDMA and HEMA), and some composite additives, causes local adverse effects (pulp changes, marginal gingivitis, and allergic reactions) and even systemic effects, with allergic, 1919. Alanko K, Susitaival P, Jolanki R, Kanerva L. Occupational skin diseases among dental nurses. Contact Dermat. 2004 Feb;50(2):77-82. https://doi.org/10.1111/j.0105-1873.2004.00304.x
https://doi.org/10.1111/j.0105-1873.2004...
cytotoxic, 2020. Brackett MG, Bouillaguet S, Lockwood PE, Rotenberg S, Lewis JB, Messer RL et al. In vitro cytotoxicity of dental composites based on new and traditional polymerization chemistries. J Biomed Mater Res B Appl Biomater. 2007 May;81(2):397-402. https://doi.org/10.1002/jbm.b.30676
https://doi.org/10.1002/jbm.b.30676...
genotoxic, and toxic potential on the reproductive system. 2121. Darmani H, Al-Hiyasat AS. The effects of BIS-GMA and TEG-DMA on female mouse fertility. Dent Mater. 2006 Apr;22(4):353-8. https://doi.org/10.1016/j.dental.2005.04.029
https://doi.org/10.1016/j.dental.2005.04...
The exact mechanism by which this occurs has not yet been established in the literature; however, the reduction in cellular glutathione levels 2222. Engelmann J, Leyhausen G, Leibfritz D, Geurtsen W. Effect of TEGDMA on the intracellular glutathione concentration of human gingival fibroblasts. J Biomed Mater Res. 2002;63(6):746-51. https://doi.org/10.1002/jbm.10465
https://doi.org/10.1002/jbm.10465...
and the increase in the levels of reactive oxygen species (ROS) are believed to be the main triggers; 2323. Samuelsen JT, Dahl JE, Karlsson S, Morisbak E, Becher R. Apoptosis induced by the monomers HEMA and TEGDMA involves formation of ROS and differential activation of the MAP-kinases p38, JNK and ERK. Dent Mater. 2007 Jan;23(1):34-9. https://doi.org/10.1016/j.dental.2005.11.037
https://doi.org/10.1016/j.dental.2005.11...
in addition, the latter has been associated with damage to cellular DNA exposed to methacrylate. 2424. Schweikl H, Spagnuolo G, Schmalz G. Genetic and cellular toxicology of dental resin monomers. J Dent Res. 2006 Oct;85(10):870-7. https://doi.org/10.1177/154405910608501001
https://doi.org/10.1177/1544059106085010...
On the other hand, Tauböck et al. 55. Tauböck TT, Marovic D, Zeljezic D, Steingruber AD, Attin T, Tarle Z. Genotoxic potential of dental bulk-fill resin composites. Dent Mater. 2017 Jul;33(7):788-95. https://doi.org/10.1016/j.dental.2017.04.011
https://doi.org/10.1016/j.dental.2017.04...
reported that the tested bulk-fill resins did not induce significant genotoxic effects on cellular DNA.

The second hypothesis, which posited that there would be no difference between the methods used for evaluating cytotoxicity, was also rejected. The neutral red test was more sensitive than MTT regarding time and concentration of the extracts. The neutral red test was directly associated with lysosomal membrane integrity, 2525. Repetto G, Peso A, Zurita JL. Neutral red uptake assay for the estimation of cell viability/cytotoxicity. Nat Protoc. 2008;3(7):1125-31. https://doi.org/10.1038/nprot.2008.75
https://doi.org/10.1038/nprot.2008.75...
while the MTT assay was associated with mitochondrial integrity. 2626. Geran RI, Greenberg NH, MacDonald MM. Protocols for screening chemical agents and natural products against animal and other biological systems. Cancer Chemother Rep. 1972;3:208-9.,2727. Mosmann T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods. 1983 Dec;65(1-2):55-63. https://doi.org/10.1016/0022-1759(83)90303-4
https://doi.org/10.1016/0022-1759(83)903...
Based on the results, the authors concluded that the toxic effect of resins at the lysosomal level precedes the effect on the mitochondria. Lysosomes participate in the apoptotic process if it is initiated by the rupture of this organelle from an exogenous stimulus, which leads to the release of lysosomal enzymes into the cellular cytoplasm, triggering a cascade of intracellular degradation events. These enzymes may directly attack the mitochondria and induce the release of cytochrome c, increase the formation of mitochondrial reactive oxygen species, and activate pro-apoptotic proteins. 2828. Zhao M, Antunes F, Eaton JW, Brunk UT. Lysosomal enzymes promote mitochondrial oxidant production, cytochrome c release and apoptosis. Eur J Bioch sept 2003 Sep; 270(18): 3778-3786. https://doi.org/10.1046/j.1432-1033.2003.03765.x
https://doi.org/10.1046/j.1432-1033.2003...
This shows that neutral red could be an important tool in the detection of initial damage at the lysosomal level, distinguish the cytotoxic effects at the cellular level from the damage to cellular organelles, and explain the different results obtained by the two methods in this study.

Notwithstanding, the neutral red test is dependent on the number of viable cells and on the lysosomal viability of cells or their function. Thus, the simultaneous use of different evaluation methods reinforces the obtained results and provides information about the possible mechanism of action of the toxin. According to Fotakis, 2929. Fotakis G, Timbrell JA. In vitro cytotoxicity assays: comparison of LDH, neutral red, MTT and protein assay in hepatoma cell lines following exposure to cadmium chloride. Toxicol Lett. 2006 Jan;160(2):171-7. https://doi.org/10.1016/j.toxlet.2005.07.001
https://doi.org/10.1016/j.toxlet.2005.07...
neutral red and MTT assays were more sensitive than the LDH and total protein tests for the detection of cytotoxicity.

The third null hypothesis, dealing with the degree of conversion and microhardness, was partially rejected, since a significant difference was found between the thicknesses of the specimens in the microhardness test. Marigo et al. 1212. Marigo L, Spagnuolo G, Malara F, Martorana GE, Cordaro M, Lupi A et al. Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites. Eur Rev Med Pharmacol Sci. 2015 Dec;19(23):4469-80. also found a statistically significant difference between the thicknesses of the test specimens (2 mm and 4 mm), corroborating the findings of this study obtained the for microhardness test. Bulk-fill flowable resins presented lower microhardness when compared to restorative resins, but the difference was not statistically significant. Similar results were obtained by Flury et al. 3030. Flury S, Peutzfeldt A, Lussi A. Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites. Dent Mater. 2014 https://doi.org/10.1016/j.dental.2014.07.001
https://doi.org/10.1016/j.dental.2014.07...
and by Garoushi et al. 3131. Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology. 2016 Sep;104(3):291-7. https://doi.org/10.1007/s10266-015-0227-0
https://doi.org/10.1007/s10266-015-0227-...
The low percentage values for load particles of the flowable composite resins may explain the data obtained. Thus, in order for these materials to withstand the conditions of the oral cavity, it is necessary to coat them with a conventional resin. 3131. Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology. 2016 Sep;104(3):291-7. https://doi.org/10.1007/s10266-015-0227-0
https://doi.org/10.1007/s10266-015-0227-...
Among flowable resins, XTB presented better VH than the other materials, which suggests that the data obtained are related to the load content of each material (manufacturer’s information), thus corroborating the findings of Zorzin et al. 3232. Zorzin J, Maier E, Harre S, Fey T, Belli R, Lohbauer U et al. Bulk-fill resin composites: polymerization properties and extended light curing. Dent Mater. 2015 Mar;31(3):293-301. https://doi.org/10.1016/j.dental.2014.12.010
https://doi.org/10.1016/j.dental.2014.12...
and of Ashali et al. 3333. ALShaafi MM, Haenel T, Sullivan B, Labrie D, Alqahtani MQ, Price RB. Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths. J Dent. 2016 Feb;45:14-8. https://doi.org/10.1016/j.jdent.2015.11.004
https://doi.org/10.1016/j.jdent.2015.11....
The data obtained in this work did not reveal a significant reduction in microhardness on the polymerization surface, indicating adequate monomer conversion. Similar results were reported by Tauböck et al. 55. Tauböck TT, Marovic D, Zeljezic D, Steingruber AD, Attin T, Tarle Z. Genotoxic potential of dental bulk-fill resin composites. Dent Mater. 2017 Jul;33(7):788-95. https://doi.org/10.1016/j.dental.2017.04.011
https://doi.org/10.1016/j.dental.2017.04...
As regards the degree of conversion, no influence of the thickness and surface subjected to polymerization was observed. Degree of conversion at the top and bottom of all resin specimens was greater than the clinically recommended values (> 55%), according to Alshali et al., 3434. Alshali RZ, Silikas N, Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater. 2013 Sep;29(9):e213-7. https://doi.org/10.1016/j.dental.2013.05.011
https://doi.org/10.1016/j.dental.2013.05...
except for AFB (4 mm) Z350F, Opus, and FBFF (2 mm) at the bottom. Other authors 3131. Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology. 2016 Sep;104(3):291-7. https://doi.org/10.1007/s10266-015-0227-0
https://doi.org/10.1007/s10266-015-0227-...
,66. Marovic D, Tauböck TT, Attin T, Panduric V, Tarle Z. Monomer conversion and shrinkage force kinetics of low-viscosity bulk-fill resin composites. Acta Odontol Scand. 2015 Aug;73(6):474-80. https://doi.org/10.3109/00016357.2014.992810
https://doi.org/10.3109/00016357.2014.99...
also obtained a good degree of conversion at 4 mm for bulk-fill resins. Higher translucency, modifications in the photoinitiator system, and incorporation of charge particles that function as “microscopic springs” into bulk-fill resins, compared to the conventional ones used in these studies (Z350 and Z350F), may explain the higher degree of conversion. This allows greater penetrability of the photopolymerizing light, thereby increasing the depth of cure. 55. Tauböck TT, Marovic D, Zeljezic D, Steingruber AD, Attin T, Tarle Z. Genotoxic potential of dental bulk-fill resin composites. Dent Mater. 2017 Jul;33(7):788-95. https://doi.org/10.1016/j.dental.2017.04.011
https://doi.org/10.1016/j.dental.2017.04...
However, ABF presented low degree of conversion on the bottom surface at 4 mm (20%), without statistical significance, drawing attention to the influence of the material on the varied results obtained. 3535. Alrahlah A, Silikas N, Watts DC. Post-cure depth of cure of bulk fill dental resin-composites. Dent Mater. 2014 Feb;30(2):149-54. https://doi.org/10.1016/j.dental.2013.10.011
https://doi.org/10.1016/j.dental.2013.10...
Statistical differences were observed among the evaluated materials, as expected, since degree of conversion is influenced by variables such as composite type, monomer composition, inorganic fraction, mass viscosity, reaction temperature, thickness of the increment, among others. 3636. Conditt M, Leinfelder K. Improving the polymerization of composite resins. Pract Proced Aesthet Dent. 2006 Apr;18(3):169-71. It should be noted that degree of conversion differs from degree of polymerization. The former refers to the percentage of conversion of carbon-carbon bonds into single bonds, while the latter corresponds to the quality of the formed polymer network in terms of chain size and is defined by the ratio between the molecular weight of the polymer and the molecular weight of the repeating polymer units. Regarding surface morphology, SEM and AFM images showed rough surfaces after the finishing and polishing with Sof-Lex discs. According to Sahbaz et al., 3737. Sahbaz C, Bahsi E, Ince B, Bakir EP, Cellik O. Effect of the different finishing and polishing procedures on the surface roughness of three different posterior composite resins. Scanning. 2016 Sep;38(5):448-54. https://doi.org/10.1002/sca.21295
https://doi.org/10.1002/sca.21295...
the use of Sof-Lex discs results in good finishing and polishing levels compared to other systems. Thus, the irregularities presented by most of the resins in this study may have been due to the displacement of load particles, which produced surface grooves when combined with the use of a rotary instrument. Clinically, increased roughness directly influences restoration esthetics, secondary caries, and patients’ periodontal health, the latter of which is associated with biofilm accumulation. 3838. Checketts MR, Turkyilmaz I, Asar NV. An investigation of the effect of scaling-induced surface roughness on bacterial adhesion in common fixed dental restorative materials. J Prosthet Dent. 2014 Nov;112(5):1265-70. https://doi.org/10.1016/j.prosdent.2014.04.005
https://doi.org/10.1016/j.prosdent.2014....
These results show the importance of this evaluation, given that five resins (ABF, FBFF, Opus, TEF, and XTF) had greater Ra values than those clinically acceptable (0.2 μm) for the enamel. Note that, although previous studies indicate that the Sof-Lex disc had good finishing/polishing outcomes, there is no universal system to perform such procedure in all resins. The indication and final outcomes produced by each system depend on the hardness, size, and content of load particles. 3939. Berger SB, Palialol AR, Cavalli V, Giannini M. Surface roughness and staining susceptibility of composite resins after finishing and polishing. J Esthet Restor Dent. 2011 Feb;23(1):34-43. https://doi.org/10.1111/j.1708-8240.2010.00376.x
https://doi.org/10.1111/j.1708-8240.2010...

Conclusion

Bulk-fill resins exhibited low and/or no cytotoxicity to L929 cells, except for Opus, which had moderate cytotoxicity, as pointed out by the MTT assay. However, when the neutral red test was used, results were not satisfactory for all composites, showing the need to use different methodologies to evaluate the properties of these materials. Yet, the resins presented acceptable values for microhardness, degree of conversion, and surface morphology.

Acknowledgements

The authors wish to thank Mr. João Batista Morais dos Santos for the technical assistance with the microhardness measurements and the Federal University of Campina Grande (UFCG) for technical support.

References

  • 1
    Moharamzadeh K, Brook IM, Scutt AM, Thornhill MH, Van Noort R. Mucotoxicity of dental composite resins on a tissue-engineered human oral mucosal model. J Dent. 2008 May;36(5):331-6. https://doi.org/10.1016/j.jdent.2008.01.019
    » https://doi.org/10.1016/j.jdent.2008.01.019
  • 2
    Salehi S, Gwinner F, Mitchell JC, Pfeifer C, Ferracane JL. Cytotoxicity of resin composites containing bioactive glass fillers. Dent Mater. 2015 Feb;31(2):195-203. https://doi.org/10.1016/j.dental.2014.12.004
    » https://doi.org/10.1016/j.dental.2014.12.004
  • 3
    Sevkusic M, Schuster L, Rothmund L, Dettinger K, Maier M, Hickel R et al. The elution and breakdown behavior of constituents from various light-cured composites. Dent Mater. 2014 Jun;30(6):619-31. https://doi.org/10.1016/j.dental.2014.02.022
    » https://doi.org/10.1016/j.dental.2014.02.022
  • 4
    Darmani H, Al-Hiyasat AS, Milhem MM. Cytotoxicity of dental composites and their leached components. Quintessence Int. 2007 Oct;38(9):789-95.
  • 5
    Tauböck TT, Marovic D, Zeljezic D, Steingruber AD, Attin T, Tarle Z. Genotoxic potential of dental bulk-fill resin composites. Dent Mater. 2017 Jul;33(7):788-95. https://doi.org/10.1016/j.dental.2017.04.011
    » https://doi.org/10.1016/j.dental.2017.04.011
  • 6
    Marovic D, Tauböck TT, Attin T, Panduric V, Tarle Z. Monomer conversion and shrinkage force kinetics of low-viscosity bulk-fill resin composites. Acta Odontol Scand. 2015 Aug;73(6):474-80. https://doi.org/10.3109/00016357.2014.992810
    » https://doi.org/10.3109/00016357.2014.992810
  • 7
    Benetti AR, Havndrup-Pedersen C, Honoré D, Pedersen MK, Pallesen U. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation. Oper Dent. 2015 Mar-Apr;40(2):190-200. https://doi.org/10.2341/13-324-L
    » https://doi.org/10.2341/13-324-L
  • 8
    Furness A, Tadros MY, Looney SW, Rueggeberg FA. Effect of bulk/incremental fill on internal gap formation of bulk-fill composites. J Dent. 2014 Apr;42(4):439-49. https://doi.org/10.1016/j.jdent.2014.01.005
    » https://doi.org/10.1016/j.jdent.2014.01.005
  • 9
    Jan YD, Lee BS, Lin CP, Tseng WY. Biocompatibility and cytotoxicity of two novel low-shrinkage dental resin matrices. J Formos Med Assoc. 2014 Jun;113(6):349-55. https://doi.org/10.1016/j.jfma.2012.07.008
    » https://doi.org/10.1016/j.jfma.2012.07.008
  • 10
    International Organization for Standardization – ISO. ISO 10993-5:2009: Biological evaluation of medical devices. Part 5: Tests for in vitro cytotoxicity. Geneve: International Organization for Standardization; 2009.
  • 11
    Toh WS, Yap AU, Lim SY. In vitro biocompatibility of contemporary bulkfill composites. Oper Dent. 2015 Nov-Dec;40(6):644-52. https://doi.org/10.2341/15-059-L
    » https://doi.org/10.2341/15-059-L
  • 12
    Marigo L, Spagnuolo G, Malara F, Martorana GE, Cordaro M, Lupi A et al. Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites. Eur Rev Med Pharmacol Sci. 2015 Dec;19(23):4469-80.
  • 13
    Ahmed RH, Aref MI, Hassan RM, Mohammed NR. Cytotoxic effect of composite resin and amalgam filling materials on human labial and buccal epithelium. Nat Sci. 2010;8(10):48-53.
  • 14
    Jang JH, Park SH, Hwang IN. Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin. Oper Dent. 2015 Mar-Apr;40(2):172-80. https://doi.org/10.2341/13-307-L
    » https://doi.org/10.2341/13-307-L
  • 15
    Karaarslan ES, Altintas S, Bulbul M, Cebe MA, Usumez A. High performance liquid chromatography analysis of monomers from one composite resin cured with different polymerization methods. Mater Res Innov. 2011 Nov;15(2):124-9. https://doi.org/10.1179/143307511X12998222918912
    » https://doi.org/10.1179/143307511X12998222918912
  • 16
    Yildirim-Bicer AZ, Ergun G, Egilmez F, Demirkoprulu H. In vitro cytotoxicity of indirect composite resins: effect of storing in artificial saliva. Indian J Dent Res. 2013 Jan-Feb;24(1):81-6. https://doi.org/10.4103/0970-9290.114962
    » https://doi.org/10.4103/0970-9290.114962
  • 17
    Tsitrou E, Kelogrigoris S, Koulaouzidou E, Antoniades-Halvatjoglou M, Koliniotou-Koumpia E, van Noort R. Effect of extraction media and storage time on the elution of monomers from four contemporary resin composite materials. Toxicol Int. 2014 Jan;21(1):89-95. https://doi.org/10.4103/0971-6580.128811
    » https://doi.org/10.4103/0971-6580.128811
  • 18
    Ak AT, Alpoz AR, Bayraktar O, Ertugrul F. Monomer release from resin based dental materials cured with LED and halogen lights. Eur J Dent. 2010 Jan;4(1):34-40.
  • 19
    Alanko K, Susitaival P, Jolanki R, Kanerva L. Occupational skin diseases among dental nurses. Contact Dermat. 2004 Feb;50(2):77-82. https://doi.org/10.1111/j.0105-1873.2004.00304.x
    » https://doi.org/10.1111/j.0105-1873.2004.00304.x
  • 20
    Brackett MG, Bouillaguet S, Lockwood PE, Rotenberg S, Lewis JB, Messer RL et al. In vitro cytotoxicity of dental composites based on new and traditional polymerization chemistries. J Biomed Mater Res B Appl Biomater. 2007 May;81(2):397-402. https://doi.org/10.1002/jbm.b.30676
    » https://doi.org/10.1002/jbm.b.30676
  • 21
    Darmani H, Al-Hiyasat AS. The effects of BIS-GMA and TEG-DMA on female mouse fertility. Dent Mater. 2006 Apr;22(4):353-8. https://doi.org/10.1016/j.dental.2005.04.029
    » https://doi.org/10.1016/j.dental.2005.04.029
  • 22
    Engelmann J, Leyhausen G, Leibfritz D, Geurtsen W. Effect of TEGDMA on the intracellular glutathione concentration of human gingival fibroblasts. J Biomed Mater Res. 2002;63(6):746-51. https://doi.org/10.1002/jbm.10465
    » https://doi.org/10.1002/jbm.10465
  • 23
    Samuelsen JT, Dahl JE, Karlsson S, Morisbak E, Becher R. Apoptosis induced by the monomers HEMA and TEGDMA involves formation of ROS and differential activation of the MAP-kinases p38, JNK and ERK. Dent Mater. 2007 Jan;23(1):34-9. https://doi.org/10.1016/j.dental.2005.11.037
    » https://doi.org/10.1016/j.dental.2005.11.037
  • 24
    Schweikl H, Spagnuolo G, Schmalz G. Genetic and cellular toxicology of dental resin monomers. J Dent Res. 2006 Oct;85(10):870-7. https://doi.org/10.1177/154405910608501001
    » https://doi.org/10.1177/154405910608501001
  • 25
    Repetto G, Peso A, Zurita JL. Neutral red uptake assay for the estimation of cell viability/cytotoxicity. Nat Protoc. 2008;3(7):1125-31. https://doi.org/10.1038/nprot.2008.75
    » https://doi.org/10.1038/nprot.2008.75
  • 26
    Geran RI, Greenberg NH, MacDonald MM. Protocols for screening chemical agents and natural products against animal and other biological systems. Cancer Chemother Rep. 1972;3:208-9.
  • 27
    Mosmann T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods. 1983 Dec;65(1-2):55-63. https://doi.org/10.1016/0022-1759(83)90303-4
    » https://doi.org/10.1016/0022-1759(83)90303-4
  • 28
    Zhao M, Antunes F, Eaton JW, Brunk UT. Lysosomal enzymes promote mitochondrial oxidant production, cytochrome c release and apoptosis. Eur J Bioch sept 2003 Sep; 270(18): 3778-3786. https://doi.org/10.1046/j.1432-1033.2003.03765.x
    » https://doi.org/10.1046/j.1432-1033.2003.03765.x
  • 29
    Fotakis G, Timbrell JA. In vitro cytotoxicity assays: comparison of LDH, neutral red, MTT and protein assay in hepatoma cell lines following exposure to cadmium chloride. Toxicol Lett. 2006 Jan;160(2):171-7. https://doi.org/10.1016/j.toxlet.2005.07.001
    » https://doi.org/10.1016/j.toxlet.2005.07.001
  • 30
    Flury S, Peutzfeldt A, Lussi A. Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites. Dent Mater. 2014 https://doi.org/10.1016/j.dental.2014.07.001
    » https://doi.org/10.1016/j.dental.2014.07.001
  • 31
    Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology. 2016 Sep;104(3):291-7. https://doi.org/10.1007/s10266-015-0227-0
    » https://doi.org/10.1007/s10266-015-0227-0
  • 32
    Zorzin J, Maier E, Harre S, Fey T, Belli R, Lohbauer U et al. Bulk-fill resin composites: polymerization properties and extended light curing. Dent Mater. 2015 Mar;31(3):293-301. https://doi.org/10.1016/j.dental.2014.12.010
    » https://doi.org/10.1016/j.dental.2014.12.010
  • 33
    ALShaafi MM, Haenel T, Sullivan B, Labrie D, Alqahtani MQ, Price RB. Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths. J Dent. 2016 Feb;45:14-8. https://doi.org/10.1016/j.jdent.2015.11.004
    » https://doi.org/10.1016/j.jdent.2015.11.004
  • 34
    Alshali RZ, Silikas N, Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater. 2013 Sep;29(9):e213-7. https://doi.org/10.1016/j.dental.2013.05.011
    » https://doi.org/10.1016/j.dental.2013.05.011
  • 35
    Alrahlah A, Silikas N, Watts DC. Post-cure depth of cure of bulk fill dental resin-composites. Dent Mater. 2014 Feb;30(2):149-54. https://doi.org/10.1016/j.dental.2013.10.011
    » https://doi.org/10.1016/j.dental.2013.10.011
  • 36
    Conditt M, Leinfelder K. Improving the polymerization of composite resins. Pract Proced Aesthet Dent. 2006 Apr;18(3):169-71.
  • 37
    Sahbaz C, Bahsi E, Ince B, Bakir EP, Cellik O. Effect of the different finishing and polishing procedures on the surface roughness of three different posterior composite resins. Scanning. 2016 Sep;38(5):448-54. https://doi.org/10.1002/sca.21295
    » https://doi.org/10.1002/sca.21295
  • 38
    Checketts MR, Turkyilmaz I, Asar NV. An investigation of the effect of scaling-induced surface roughness on bacterial adhesion in common fixed dental restorative materials. J Prosthet Dent. 2014 Nov;112(5):1265-70. https://doi.org/10.1016/j.prosdent.2014.04.005
    » https://doi.org/10.1016/j.prosdent.2014.04.005
  • 39
    Berger SB, Palialol AR, Cavalli V, Giannini M. Surface roughness and staining susceptibility of composite resins after finishing and polishing. J Esthet Restor Dent. 2011 Feb;23(1):34-43. https://doi.org/10.1111/j.1708-8240.2010.00376.x
    » https://doi.org/10.1111/j.1708-8240.2010.00376.x

Publication Dates

  • Publication in this collection
    25 Oct 2018
  • Date of issue
    2018

History

  • Received
    22 Jan 2018
  • Accepted
    21 May 2018
  • Reviewed
    30 Aug 2018
Sociedade Brasileira de Pesquisa Odontológica - SBPqO Av. Prof. Lineu Prestes, 2227, 05508-000 São Paulo SP - Brazil, Tel. (55 11) 3044-2393/(55 11) 9-7557-1244 - São Paulo - SP - Brazil
E-mail: office.bor@ingroup.srv.br