Acessibilidade / Reportar erro

Effect of implant crestal position on primary stability before and after loading: an in vitro study

Efeito do posicionamento crestal do implante na estabilidade primária antes e após carga: um estudo in vitro

Abstract

Introduction

Primary stability is one of the goals of modern implant dentistry and if achieved, reduces treatment time for prosthetic rehabilitation and the number of interventions made in patients mouth. Several companies state as protocol for connical conection implants, a subcrestally positioning.

Objective

This in vitro study aimed to evaluate the effect of placing a conical connection implant equicrestally and subcrestally on static and loading condition in two types of bone density.

Material and method

A total of 200 bone cylinders were extracted from femur of pigs, standardized by means of x-rays and computerized microtomography scan (microCT) and separated in low and high density specimens. The implants were placed on the center of the bone cylinders and were evaluated before and after loading by means of microCT and histomorphometry.

Result

The results showed that placing the evaluated implant subcrestally provided better primary stability and performance on static and loading situations on low and high density bone.

Conclusion

Placing implant subcrestally improve primary stability outcomes under loading and static situations.

Descriptors:
Dental implants; primary stability; in vitro techniques; X-Ray microtomography; pull out test

Resumo

Introdução

A estabilidade primária é um dos objetivos da implantodontia moderna e, caso atingida, reduz o tempo de tratamento para a reabilitação protéticas e o número de intervenções realizadas. Diversas empresas preconizam a posição subcrestal no uso de implantes com conexão cônica interna.

Objetivo

Este estudo in vitro avaliou o efeito do posicionamento de implantes de conexão conica interna sub e equicrestal sob condições estáticas e em função, considerando dois tipos de densidades ósseas.

Material e método

um total de 200 espécimes de osso extraído do femur de suínos e padronizados por meio de radiografias e microtomografias computadorizadas foram separados em densidade alta e baixa. Implantes foram instalados no centro dos especimes e for a avaliados por meio de microCT e histomorfometria.

Resultado

Os resultados demonstraram que a colocação de implante subcrestalmente promoveu melhor estabilidade primária e performance em todas as situações, irrespectivamente à densidade óssea.

Conclusão

A colocação de implantes subcrestalmente melhora a estabilidade primária em todas as situações, sendo indicada quando da utilização de conexões cônicas internas.

Descritores:
Implantes dentais; técnica in vitro; microtomografia; teste de arrancamento

INTRODUCTION

Oral rehabilitation with osseointegrated dental implants have been applied for many years since the first description of the osseointegration11 Brånemark PI, Breine U, Adell R, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg. 1969;3(2):81-100. http://dx.doi.org/10.3109/02844316909036699. PMid:4924041.
http://dx.doi.org/10.3109/02844316909036...
, and one of the requirements for success was a stress-free healing period of 3-6 months11 Brånemark PI, Breine U, Adell R, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg. 1969;3(2):81-100. http://dx.doi.org/10.3109/02844316909036699. PMid:4924041.
http://dx.doi.org/10.3109/02844316909036...

2 Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981 Dec;10(6):387-416. http://dx.doi.org/10.1016/S0300-9785(81)80077-4. PMid:6809663.
http://dx.doi.org/10.1016/S0300-9785(81)...

3 Albrektsson T. Direct bone anchorage of dental implants. J Prosthet Dent. 1983 Aug;50(2):255-61. http://dx.doi.org/10.1016/0022-3913(83)90027-6. PMid:6352912.
http://dx.doi.org/10.1016/0022-3913(83)9...
-44 Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132. PMid:356184.. Later, immediate loading has been proposed in order to reduce the treatment time55 Piattelli A, Ruggeri A, Franchi M, Romasco N, Trisi P. An histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: a pilot study. J Oral Implantol. 1993;19(4):314-20. PMid:8007025.

6 Piattelli A, Corigliano M, Scarano A, Quaranta M. Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: a pilot study in monkeys. Int J Periodontics Restorative Dent. 1997 Apr;17(2):162-9. PMid:9497710.
-77 Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants. 1997 May-Jun;12(3):319-24. PMid:9197096.. This is a prerequisite for immediate loading and it is influenced by many factors, such as bone density, implant geometry, cortical thickness and cortical bone density88 Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998 Sep-Oct;11(5):491-501. PMid:9922740.,99 Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res. 2004 Oct;15(5):529-39. http://dx.doi.org/10.1111/j.1600-0501.2004.01042.x. PMid:15355394.
http://dx.doi.org/10.1111/j.1600-0501.20...
.

Implants with conical geometry and morse taper prosthetic connection have been successfully applied on oral rehabilitation with minimal marginal bone loss, usually attributed to its natural platform shift characteristics1010 Mangano C, Iaculli F, Piattelli A, Mangano F. Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10-20 years of follow-up. Clin Oral Implants Res. 2015 Oct;26(10):1229-36. http://dx.doi.org/10.1111/clr.12439. PMid:24954285.
http://dx.doi.org/10.1111/clr.12439...
. However, there is still a discussion regarding the position of the implant in relation to the bone crest1111 Fetner M, Fetner A, Koutouzis T, Clozza E, Tovar N, Sarendranath A, et al. The effects of subcrestal implant placement on crestal bone levels and bone-to-abutment contact: a microcomputed tomographic and histologic study in dogs. Int J Oral Maxillofac Implants. 2015 Sep-Oct;30(5):1068-75. http://dx.doi.org/10.11607/jomi.4043. PMid:26394343.
http://dx.doi.org/10.11607/jomi.4043...

12 Romanos GE, Aydin E, Gaertner K, Nentwig GH. Long-term results after subcrestal or crestal placement of delayed loaded implants. Clin Implant Dent Relat Res. 2015 Feb;17(1):133-41. http://dx.doi.org/10.1111/cid.12084. PMid:23675969.
http://dx.doi.org/10.1111/cid.12084...
-1313 Calvo-Guirado JL, Lopez-Lopez PJ, Mate Sanchez JE, Gargallo Albiol J, Velasco Ortega E, Delgado Ruiz R. Crestal bone loss related to immediate implants in crestal and subcrestal position: a pilot study in dogs. Clin Oral Implants Res. 2014 Nov;25(11):1286-94. http://dx.doi.org/10.1111/clr.12267. PMid:24118345.
http://dx.doi.org/10.1111/clr.12267...
. Little is known about the influence of the subcrestal/crestal positioning on biomechanics of implant-supported rehabilitations and its stability on immediate loading situations.

In clinical settings, primary stability can be quantified within implant insertion by measuring the torque achieved with a torquimeter attached to a rachet or with the handpiece, at the end of implant insertion. It can also be measured by means of a resonance frequency analysis (RFA) made by a special apparatus1414 Degidi M, Daprile G, Piattelli A, Carinci F. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus‐augmented and nongrafted sites. Clin Implant Dent Relat Res. 2007 Sep;9(3):144-9. http://dx.doi.org/10.1111/j.1708-8208.2007.00042.x. PMid:17716258.
http://dx.doi.org/10.1111/j.1708-8208.20...

15 Schincaglia GP, Marzola R, Scapoli C, Scotti R. Immediate loading of dental implants supporting fixed partial dentures in the posterior mandible: a randomized controlled split-mouth study--machined versus titanium oxide implant surface. Int J Oral Maxillofac Implants. 2007 Jan-Feb;22(1):35-46. PMid:17340895.
-1616 Balshi SF, Allen FD, Wolfinger GJ, Balshi TJ. A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants. 2005 Jul-Aug;20(4):584-94. PMid:16161743.. Due to its non-invasiveness and non-destructive characteristics, RFA has been established as a quantitative measurement of implant integration by assessing changes in implant stability over time1717 Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996 Sep;7(3):261-7. http://dx.doi.org/10.1034/j.1600-0501.1996.070308.x. PMid:9151590.
http://dx.doi.org/10.1034/j.1600-0501.19...
. On in vitro settings, the pullout strength assay analyzes the resistance of the implants based on the physical and chemical properties of the screw, with the inconvenience of destroying the specimen.

Dantas et al.1818 Dantas CDF, Reino DM, Carvalho JP, Novaes Jr AB, Taba Jr M, Bazan Palioto D, et al. Evaluation of standardized porcine bone models to test primary stability of dental implants, using biomechanical tests and Micro-CT. An in vitro pilot study. J Osseointegr. 2015;7(3). successfully evaluated standardized porcine bone models in order to avoid the use of living subjects and reducing the use of animals to test primary stability of dental implants in static situation. This technique was capable to obtain specimens with standardized bone density, mimiquing high density and low density bone. This in vitro model substituted a synthetic one1919 Ahn SJ, Leesungbok R, Lee SW, Heo YK, Kang KL. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study. J Prosthet Dent. 2012 Jun;107(6):366-72. http://dx.doi.org/10.1016/S0022-3913(12)60092-4. PMid:22633592.
http://dx.doi.org/10.1016/S0022-3913(12)...
with a considerable advantage of the ability of using non-mechanical tests such as x-rays, microtomography (microCT) and histology to evaluate periimplant bone. The use of of natural bone gives the possibility of a number of analysis including histologics slices, mimiquing the clinical setting in implant dentistry. In addition this model can also be evaluated three-dimentionally with the aid of microCT and a accurate mesurement of the effect of implant insertion in different bone densities is possible quantitavely and qualitatively. To date, no data has been published using this novel model in loading situations.

The aim of this study is to evaluate the effect of implant positioning (crestal/subcrestal) on primary stability, with or without axial or non-axial load, by means of microtomographical and mechanical analysis, in a standardized porcine model of high and low-density bone.

MATERIAL AND METHOD

Specimen Standardization Phase

A total of 200 bone cylinders from porcine origin were prepared and evaluated by digital radiography as previously described1818 Dantas CDF, Reino DM, Carvalho JP, Novaes Jr AB, Taba Jr M, Bazan Palioto D, et al. Evaluation of standardized porcine bone models to test primary stability of dental implants, using biomechanical tests and Micro-CT. An in vitro pilot study. J Osseointegr. 2015;7(3). . Briefly, bone was removed using an especially designed trephine burr in order to obtain specimens with 15x18mm dimension (Figure 1A and 1B). After removal, they were kept frozen and stored at -20° C.

Figure 1
Custom made trephine for collection of bone specimens (A); bone cylinders prepared and identified (B); 2D and 3D analysis showing high density (C and E) and low density (D and F) specimens.

Before implant insertion, the bone density of the cylinders was certified by two-dimensional radiographic analysis (2D analysis) using a digital X-Ray sensor (RVG Trophy, Eastman Kodak Company, Rochester, NY, EUA)) and a computer software (Image Tool for Windows, version 3.00, UTHSCSA, San Antonio TX, EUA) to determine 2D bone density, as previously described by Dantas et al.1818 Dantas CDF, Reino DM, Carvalho JP, Novaes Jr AB, Taba Jr M, Bazan Palioto D, et al. Evaluation of standardized porcine bone models to test primary stability of dental implants, using biomechanical tests and Micro-CT. An in vitro pilot study. J Osseointegr. 2015;7(3). . The cylinders were then grouped according to their 2D bone densities: values equal or greater than 110 were selected for High bone density cylinders (cylinders removed from femur head), and with values equal or lower than 80 were selected for Low bone density cylinders (cylinders removed from the mandibular condyle); the cylinders with intermediate values were discarded, and a total of 60 cylinders were selected (30 for low density group, 30 for high density) for the experiment.

Before insertion of the implants in bone cylinders, 3D morphometric analysis was performed using the Micro-Sky Scan 1172-160 (SkyScan, Kontich, Belgium). Micro-CT scans of each bone cylinder were taken for the evaluation of tomographic bone parameters (Figures 1C, 1D, 1E, 1F). Using the analysis software (CTan Analyser) to quantify microstructures, the volume region of interest (VOI) was determined for 3D morphometric analysis. The tomographic parameters evaluated in the bone cylinders were tridimensional bone density (BV/TV), trabecular separation (Tb.Sp); percentage of total porosity (Po.tot) and bone surface/volume ratio (BS/BV).

Implant Installation

Sixty implants were selected for this study, measuring 3.5 x 10mm (Alvim Cone Morse - Neodent®, Curitiba, Brazil). According to the manufacturer, these implants have a conical body, twin screw and morse tape prosthetic platform.

The bone cylinders were fixed and immobilized in a specially designed base to avoid displacement during the drilling process (Figure 2A). The surgical site was prepared with progressive drilling sequence, at 800 rpm, with abundant saline solution irrigation, following the protocol recommended by the manufacturer (Neodent®, Curitiba, Brazil). After site preparation, the implants were inserted into the bone cylinders (one implant in each cylinder), according to the four experimental groups (Figures 2B to 2G):

Figure 2
Device designed to hold the bone cylinder in position (A); drilling sequence (B-E); implant installation (F); implant installed on the bone cylinder (G: crestal position; H: 2mm subcrestal position); abutment connected to the implant (I and J); ISQ being measured (K); axial and non-n axial loading (L and M); and the pullout test (N).
  • Experimental Group 1 (G1): implant placed in the high-density bone cylinder at crestal bone level (n = 15);

  • Experimental Group 2 (G2): implant placed in the high-density bone cylinder at 2mm subcrestally (n=15);

  • Experimental Group 3 (G3): implant placed in the low-density bone cylinder at crestal bone level (n =15);

  • Experimental Group 4 (G4): implant placed in the low-density bone cylinder at 2 mm subcrestally (n= 15).

Primary Stability Evaluation

Immediately after implant installation, insertion torque (IT) and ISQ levels were recorded. The IT measurement was performed using an micromotor and a reduction handpiece that precisely measures the handpiece torque in 0.1N.cm intervals (iChiropro, BienAir-Dental, Switzerland). The last torque value measured after implant complete insertion was taken into account for statistics as IT. Following that, Ressonance Frequency Analysis was recorded using Osstell (Osstell ISQ, Göteborg, Sweden), and the Implant Stability Quocient (ISQ) was recorded (Figure 2K). Then, another tomographic 3D analysis was performed to evaluate the tomographic bone to implant contact (Figure 3), as the intersection bone to implant surface/total implant surface (IS/TS), and all the previous described parameters, in 2 bone levels: L1- bone internal to the threads; L2 - bone immediately adjacent to the end of threads (Figure 4).

Figure 3
3D reconstruction of the implant and the two areas of microCT analysis (in pink L1 and in blue L2).
Figure 4
3D reconstruction of L1 (pink) and L2 (blue) for high bone density (A, B and C) and low bone density (D, E and F) cylinders.

Loading Phase

Five implants from each group were submitted to axial (Figure 2L) and non- axial (Figure 2M) (non-axial load, in 45o degree angulation) loads, while the other 5 did not receive loading forces. Loading was performed as previously described2020 Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van Der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998 Nov;25(11):847-58. http://dx.doi.org/10.1046/j.1365-2842.1998.00318.x. PMid:9846905.
http://dx.doi.org/10.1046/j.1365-2842.19...
. Briefly, the implants were placed in a Universal Testing Machine (EMIC®, DL-10000N- São José dos Pinhais, Brazil) and loading was progressive applied until it reaches 150N/cm with 1mm/min speed. After applications of axial and non-axial forces in the selected bone cylinders, new Micro-CT scans and micro-tomographic reconstructions were performed, evaluating the same tomographic parameters previously described. A new resonance frequency analysis was performed and, after that, pull out test was accomplished.

The pullout test was conducted at the Laboratory of Bioengineering from the Faculty of Medicine of Ribeirão Preto. The bone cylinder containing the implant was positioned in the Universal Testing Machine (EMIC®, DL-10000N- São José dos Pinhais, Brazil) and connected to a mobile base by a device specially designed and screwed to the implant. After that, a load cell of 200kg was adjusted, and, after a pre-load of 10N for 30 seconds, an axial tensile strength with constant speed of 2mm/min was applied (Figure 2N). The force that broke up bone to implant interface was then measure in Newtons and recorded as the Pullout strength force for that specimen.

Statistical Analysis

All variables were tested for normality of data; according to the result, parametric (t Test) test was used for intra-groups analysis, and nonparametric test (Mann-Whitney Test Whitney Test) for inter-group evaluation. For all analysis, a significance level of 5% was considered.

RESULT

Trabecular Separation (Tb.Sp)

The intra-group analysis showed significant differences for all the groups, pre and post implant placement, indicating bone compacting within the implant insertion. There was statistical significance between G2 versus G4 regarding the difference between before and after loading. After non-axial load, there were significant differences between G2 versus G4 and between G3 versus G4 for the adjacent area. The trabecular separation after loading significantly decreased for all groups, showing that there was a significant difference of bone compaction after loading, with higher values associated to the low density bone cylinders (Table 1).

Table 1
Mean Values ± SD of Trabecular Separation (Tb.Sp) between groups

Percentage of Total Porosity (Po.tot)

There was a significant reduction of Po.tot for all groups after implant placement. When the differences in Po.tot (ΔPo.tot) were considered, there was a significant difference between all groups after axial load, when compared to the pre-load situation. The non-axial load showed an increase in Po.tot values for all the groups, with significant differences between G2 versus G1 and between G2 versus G4. In G2, it was observed a reduction of the Po.tot after both loading situations (Table 2).

Table 2
Mean Values ± SD of Percentage of total porosity (PO TOT) between groups

Bone Surface / Volume Ratio (BS/BV)

When the bone density was high (G1 and G2), no differences were found after loading. In low-density bone, there was a significant difference between G3 versus G4 for the ratios obtained before and after implant installation. The axial load numerically increased the BS/BV in all groups, and there were significant differences between G3 versus G4, G1 versus G3, and G2 versus G4. When non-axial load was applied, there were significant differences between G2 versus G4, and G1 versus G3 (Table 3).

Table 3
Mean Values ± SD of Bone Surface/ volume ratio (BS/BV) between groups

Tridimensional Bone to Implant Contact (IS/TS)

Overall results showed no signifcant differences on Tridimensional Bone to Implant contact before and after loading on high density bone. On low density bone, there was a significant decrease on IS/TS after oclusal and axial loading.

After axial load it was observed a significant difference between G2 versus G4 and between G1 versus G2. After non-axial load, there were significant differences between G1 versus G3, and G2 versus G4 (Table 4).

Table 4
Mean Values ± SD of Bone Implant Contact (BIC) between groups

Resonance Frequency Analysis

There were no significant differences between G1 versus G3 and between G2 versus G4 at implants placement and after loading. Implants placed subcrestally (G2 versus G4) exhibited higher numeric ISQ values at both densities in static and loading situations, although without significant differences.

Biomechanical Tests

The mean and standard deviation insertion torque values were: 40.70 ± 6.74 N.cm, 45.46 ±7.99 N.cm, 26.86 ± 7.42 N.cm and 30.44 ± 8.18 N.cm for G1, G2, G3 and G4, respectively. The differences were statistically significant between G1 versus G3 and between G2 versus G4 (p<0.05).

In the Pullout strength test, the mean and standard deviation values of implants that received axial and non axial forces, were respectively: Group 1: 472.10 ± 232.30 and 511.50 ± 184.60; Group 2: 506.40 ± 94.01 and 395.30 ± 63.15; Group 3: 190.10 ± 106.80 and 647.20 ± 172.80 and Group 4: 268.30 ± 98.13 e 392.70 ± 186.50. There were significant differences between G1 versus G3, and G1 versus G4 at static situation. After axial load there were significant differences between G1 versus G3, and between G2 versus G4. When the non- axial load was applied to the low bone density, the values were higher than pre-load, and a significant difference could be detected between G3 versus G4.

DISCUSSION

This is a novel in vitro study, evaluating the effects of the position of the implant after insertion in different bone densities on the biomechanics and adjacent bone, in non-loaded and loaded situations. Overall results showed that inserting a morse taper implant 2 mm subcrestally represents better biomechanical settings than inserting it at crestal level.

To date, few studies had used standardized in vitro models to evaluate tridimensional changes caused by implant placement in different bone densities. This model resembles with a good reproducibility high-density and low-density bone, comparable to types 1 and 2, and 3 and 4, respectively. This is the first study to mimic axial and non-axial loading to analyze its effect on implant primary stability and bone compacting in this bone model.

Clinically, implants are placed subcrestally due to esthetic demands, to improve initial stability, especially in case of immediate implants, or in cases presenting insufficient inter-occlusal height for proper restoration2121 Hämmerle CH, Brägger U, Bürgin W, Lang NP. The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues. Clin Oral Implants Res. 1996 Jun;7(2):111-9. http://dx.doi.org/10.1034/j.1600-0501.1996.070204.x. PMid:9002829.
http://dx.doi.org/10.1034/j.1600-0501.19...
,2222 Degidi M, Nardi D, Daprile G, Piattelli A. Nonremoval of immediate abutments in cases involving subcrestally placed postextractive tapered single implants: a randomized controlled clinical study. Clin Implant Dent Relat Res. 2014 Dec;16(6):794-805. http://dx.doi.org/10.1111/cid.12051. PMid:23458566.
http://dx.doi.org/10.1111/cid.12051...
. Primary stability is influenced by various factors, including bone quality and quantity, implant geometry, and cortical bone thickness88 Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998 Sep-Oct;11(5):491-501. PMid:9922740.,2323 Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study. Bone. 2005 Dec;37(6):776-80. http://dx.doi.org/10.1016/j.bone.2005.06.019. PMid:16154396.
http://dx.doi.org/10.1016/j.bone.2005.06...
,2424 Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont. 1998 Sep-Oct;11(5):408-20. PMid:9922733.. It has been reported that the primary stability is affected by cortical bone thickness and trabecular bone density99 Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res. 2004 Oct;15(5):529-39. http://dx.doi.org/10.1111/j.1600-0501.2004.01042.x. PMid:15355394.
http://dx.doi.org/10.1111/j.1600-0501.20...
. In the present study, the highest mean values for insertion torque were obtained in high density bone (G1 and G2), with significant difference between implants with the same position and different bone densities (G1 versus G3 and G2 versus G4). Those results are in agreement with a previous study in a different in vitro model, that showed a significant difference in micromovimentation of implants in soft bone (low density), including in implants with insertion torque considered clinically acceptable to immediate loading2525 Trisi P, Perfetti G, Baldoni E, Berardi D, Colagiovanni M, Scogna G. Implant micromotion is related to peak insertion torque and bone density. Clin Oral Implants Res. 2009 May;20(5):467-71. http://dx.doi.org/10.1111/j.1600-0501.2008.01679.x. PMid:19522976.
http://dx.doi.org/10.1111/j.1600-0501.20...
.

When the primary stability was measured by means of RFA, no difference could be detected between groups. However, the mean values of ISQ were higher in the high density bone groups for subcrestal implant positioning (G1=74.4 versus G2=76.7; G3=72.7 versus G4=75.3;), suggesting that subcrestal placement of implants could improve the initial stability in low density bone such as in posterior maxilla2626 Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res. 2001 Oct;12(5):423-32. http://dx.doi.org/10.1034/j.1600-0501.2001.120501.x. PMid:11564101.
http://dx.doi.org/10.1034/j.1600-0501.20...
,2727 Devlin H, Horner K, Ledgerton D. A comparison of maxillary and mandibular bone mineral densities. J Prosthet Dent. 1998 Mar;79(3):323-7. http://dx.doi.org/10.1016/S0022-3913(98)70245-8. PMid:9553887.
http://dx.doi.org/10.1016/S0022-3913(98)...
. After loading, an increase in ISQ values was observed in the groups that received subcrestal implants placement (G2: 83.3 for axial load and 86.3 for non -axial load; G4: 84.7 axial load and 85.3 for non-axial load), while a reduction was observed for the implants placed at crestal level (G1: 71.50 for axial load and 73.45 for non-axial load e G3: 73.06 for axial load, 70.20 for non-axial load), suggesting a higher bone compression for the subcrestal implants. The lowest values were found in low-density bone groups and it is in agreement with a previous clinical study, that reported mean values of 68.51 and 72.84 in maxilla and mandible, respectively.

The pullout test has been previously used to evaluate primary stability in vitro (66-69). In the present study, the highest values were observed in the high-density groups G1: 564.66 and G2: 443.45, while the low-density groups (G3 and G4) showed 226.38 and 298.74, respectively. Similar results were reported in studies using high-density substrates such as pine wood and a polyurethane 40PCF bone simulator2828 Oliscovicz NF, Shimano AC, Marcantonio E Jr, Lepri CP, Dos Reis AC. Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque. Int J Dent. 2013;2013:194987. http://dx.doi.org/10.1155/2013/194987. PMid:23431301.
http://dx.doi.org/10.1155/2013/194987...
.

The use of microCT to analyze bone density is considered an objective and reliable method2929 Turkyilmaz I, Aksoy U, McGlumphy EA. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Clin Implant Dent Relat Res. 2008 Dec;10(4):231-7. http://dx.doi.org/10.1111/j.1708-8208.2008.00084.x. PMid:18384409.
http://dx.doi.org/10.1111/j.1708-8208.20...
. It was first described in 19873030 Schwarz MS, Rothman SL, Rhodes ML, Chafetz N. Computed tomography: Part I. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants. 1987;2(3):137-41. PMid:3481354.. In the past years it has been used in studies to evaluate bone density and implant stability3131 Ikumi N, Tsutsumi S. Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study. Int J Oral Maxillofac Implants. 2005 Mar-Apr;20(2):253-60. PMid:15839119.,3232 Lundgren S, Anderson S, Gualini F, Sennerby L. Bone reformation with sinus membrane elevation: a new surgical technique for maxillary sinus floor augmentation. Clin Implant Dent Relat Res. 2004;6(3):165-73. http://dx.doi.org/10.1111/j.1708-8208.2004.tb00224.x. PMid:15726851.
http://dx.doi.org/10.1111/j.1708-8208.20...
.

Trabecular separation showed statistically significant difference between all the groups for the pre- implant versus post- implant comparisons (p<0.05). Therefore, it was observed an increasing in bone compression during insertion, more evident in low bone densities groups. The variation values showed statistically significant differences between G2 versus G4; the higher values were observed after non- axial loading, and confirms the deleterious effects of lateral forces on dental implants. The inappropriate immediate loading can cause failure in oral implants, as previously showed in literature3333 Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci. 1998 Jun;106(3):721-64. http://dx.doi.org/10.1046/j.0909-8836..t01-6-.x. PMid:9672097.
http://dx.doi.org/10.1046/j.0909-8836..t...

34 Norton MR. The influence of insertion torque on the survival of immediately placed and restored single-tooth implants. Int J Oral Maxillofac Implants. 2011 Nov-Dec;26(6):1333-43. PMid:22167441.

35 De Bruyn H, Raes S, Ostman PO, Cosyn J. Immediate loading in partially and completely edentulous jaws: a review of the literature with clinical guidelines. Periodontol 2000. 2014 Oct;66(1):153-87. http://dx.doi.org/10.1111/prd.12040. PMid:25123767.
http://dx.doi.org/10.1111/prd.12040...

36 Moraschini V, Porto Barboza E. Immediate versus conventional loaded single implants in the posterior mandible: a meta-analysis of randomized controlled trials. Int J Oral Maxillofac Surg. 2016 Jan;45(1):85-92. http://dx.doi.org/10.1016/j.ijom.2015.07.014. PMid:26259980.
http://dx.doi.org/10.1016/j.ijom.2015.07...
-3737 Benic GI, Mir-Mari J, Hammerle CH. Loading protocols for single-implant crowns: a systematic review and meta-analysis. Int J Oral Maxillofac Implants. 2014;29(Suppl):222-38. http://dx.doi.org/10.11607/jomi.2014suppl.g4.1. PMid:24660200.
http://dx.doi.org/10.11607/jomi.2014supp...
.

The total porosity showed significant differences between pre and post-implant at all groups (p<0.05). Those differences are expected due to a bone compaction after implant placement, as well after loading. Delta values showed significant differences between all the groups, and subcrestal implant placement promoted reduced values of porosity showing an additional bone compacting in comparison to crestal placement.

The three-dimensional BS/BV analysis showed significant differences for same bone level and different bone densities (between G1 versus G3 and G2 versus G4) indicating that the BS/BV is affected by bone density. BV/TV analysis showed significant differences for all the groups between pre-loading and post-loading. However, the lower variations were observed for G2, with higher stability after the loading challenge.

The intersection bone to implant surface/total implant surface (IS/TS) values showed significant reduction after the non-axial load in low bone densities groups, indicating trabecular disorganization after loading. Osseous density shows an important role on primary stability of implants, and has been focus of research in recently3838 Huwais S, Meyer EG. A novel osseous densification approach in implant osteotomy preparation to increase biomechanical primary stability, bone mineral density, and bone-to-implant contact. Int J Oral Maxillofac Implants. 2017 Jan/Feb;32(1):27-36. http://dx.doi.org/10.11607/jomi.4817. PMid:27741329.
http://dx.doi.org/10.11607/jomi.4817...
. The IS/TS measured in the present study refers to primary stability and cannot be compared with in vivo studies reporting histological data. The deleterious effect of non-axial loading to IS/TS values is an important data regarding the protection of non-physiological loading, especially on initial healing phase in order to avoid disruption of the osseointegration biological process.

This is an in vitro study and the influence of secondary stability (osseointegration) is not being evaluated. The tridimensional bone to implant contact values after load represents an in vivo/clinical situation immediately after the loading and cannot be extrapolated to a live tissue setting. On the other hand, to date, it would be impossible to achieve an optimal standardization of bone quality and density considering an in vivo setting in order to perform biomechanical studies.

Within the limitations of this study, the subcrestally positioned dental implant had shown advantages for the primary stability of implants placed in low-density and high-density bone. Further in vivo studies might be necessary to confirm this statement and evaluate the effect of this primary stability on the osseointegration and secondary stability of dental implants.

ACKNOWLEDGEMENTS

The authors would like to thank laboratory technician Adriana Luisa Gonçalves de Almeida for her assistance in the experimental procedures.

  • How to cite: Carvalho JP, Ramos UD, Sousa LG, Vasconcelos PB, Messora MR, Palioto DB, et al. Effect of implant crestal position on primary stability before and after loading: an in vitro study. Rev Odontol UNESP. 2022;51:e20220047. https://doi.org/10.1590/1807-2577.04722

REFERENCES

  • 1
    Brånemark PI, Breine U, Adell R, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg. 1969;3(2):81-100. http://dx.doi.org/10.3109/02844316909036699 PMid:4924041.
    » http://dx.doi.org/10.3109/02844316909036699
  • 2
    Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981 Dec;10(6):387-416. http://dx.doi.org/10.1016/S0300-9785(81)80077-4 PMid:6809663.
    » http://dx.doi.org/10.1016/S0300-9785(81)80077-4
  • 3
    Albrektsson T. Direct bone anchorage of dental implants. J Prosthet Dent. 1983 Aug;50(2):255-61. http://dx.doi.org/10.1016/0022-3913(83)90027-6 PMid:6352912.
    » http://dx.doi.org/10.1016/0022-3913(83)90027-6
  • 4
    Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132. PMid:356184.
  • 5
    Piattelli A, Ruggeri A, Franchi M, Romasco N, Trisi P. An histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: a pilot study. J Oral Implantol. 1993;19(4):314-20. PMid:8007025.
  • 6
    Piattelli A, Corigliano M, Scarano A, Quaranta M. Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: a pilot study in monkeys. Int J Periodontics Restorative Dent. 1997 Apr;17(2):162-9. PMid:9497710.
  • 7
    Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants. 1997 May-Jun;12(3):319-24. PMid:9197096.
  • 8
    Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998 Sep-Oct;11(5):491-501. PMid:9922740.
  • 9
    Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res. 2004 Oct;15(5):529-39. http://dx.doi.org/10.1111/j.1600-0501.2004.01042.x PMid:15355394.
    » http://dx.doi.org/10.1111/j.1600-0501.2004.01042.x
  • 10
    Mangano C, Iaculli F, Piattelli A, Mangano F. Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10-20 years of follow-up. Clin Oral Implants Res. 2015 Oct;26(10):1229-36. http://dx.doi.org/10.1111/clr.12439 PMid:24954285.
    » http://dx.doi.org/10.1111/clr.12439
  • 11
    Fetner M, Fetner A, Koutouzis T, Clozza E, Tovar N, Sarendranath A, et al. The effects of subcrestal implant placement on crestal bone levels and bone-to-abutment contact: a microcomputed tomographic and histologic study in dogs. Int J Oral Maxillofac Implants. 2015 Sep-Oct;30(5):1068-75. http://dx.doi.org/10.11607/jomi.4043 PMid:26394343.
    » http://dx.doi.org/10.11607/jomi.4043
  • 12
    Romanos GE, Aydin E, Gaertner K, Nentwig GH. Long-term results after subcrestal or crestal placement of delayed loaded implants. Clin Implant Dent Relat Res. 2015 Feb;17(1):133-41. http://dx.doi.org/10.1111/cid.12084 PMid:23675969.
    » http://dx.doi.org/10.1111/cid.12084
  • 13
    Calvo-Guirado JL, Lopez-Lopez PJ, Mate Sanchez JE, Gargallo Albiol J, Velasco Ortega E, Delgado Ruiz R. Crestal bone loss related to immediate implants in crestal and subcrestal position: a pilot study in dogs. Clin Oral Implants Res. 2014 Nov;25(11):1286-94. http://dx.doi.org/10.1111/clr.12267 PMid:24118345.
    » http://dx.doi.org/10.1111/clr.12267
  • 14
    Degidi M, Daprile G, Piattelli A, Carinci F. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus‐augmented and nongrafted sites. Clin Implant Dent Relat Res. 2007 Sep;9(3):144-9. http://dx.doi.org/10.1111/j.1708-8208.2007.00042.x PMid:17716258.
    » http://dx.doi.org/10.1111/j.1708-8208.2007.00042.x
  • 15
    Schincaglia GP, Marzola R, Scapoli C, Scotti R. Immediate loading of dental implants supporting fixed partial dentures in the posterior mandible: a randomized controlled split-mouth study--machined versus titanium oxide implant surface. Int J Oral Maxillofac Implants. 2007 Jan-Feb;22(1):35-46. PMid:17340895.
  • 16
    Balshi SF, Allen FD, Wolfinger GJ, Balshi TJ. A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants. 2005 Jul-Aug;20(4):584-94. PMid:16161743.
  • 17
    Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996 Sep;7(3):261-7. http://dx.doi.org/10.1034/j.1600-0501.1996.070308.x PMid:9151590.
    » http://dx.doi.org/10.1034/j.1600-0501.1996.070308.x
  • 18
    Dantas CDF, Reino DM, Carvalho JP, Novaes Jr AB, Taba Jr M, Bazan Palioto D, et al. Evaluation of standardized porcine bone models to test primary stability of dental implants, using biomechanical tests and Micro-CT. An in vitro pilot study. J Osseointegr. 2015;7(3).
  • 19
    Ahn SJ, Leesungbok R, Lee SW, Heo YK, Kang KL. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study. J Prosthet Dent. 2012 Jun;107(6):366-72. http://dx.doi.org/10.1016/S0022-3913(12)60092-4 PMid:22633592.
    » http://dx.doi.org/10.1016/S0022-3913(12)60092-4
  • 20
    Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van Der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998 Nov;25(11):847-58. http://dx.doi.org/10.1046/j.1365-2842.1998.00318.x PMid:9846905.
    » http://dx.doi.org/10.1046/j.1365-2842.1998.00318.x
  • 21
    Hämmerle CH, Brägger U, Bürgin W, Lang NP. The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues. Clin Oral Implants Res. 1996 Jun;7(2):111-9. http://dx.doi.org/10.1034/j.1600-0501.1996.070204.x PMid:9002829.
    » http://dx.doi.org/10.1034/j.1600-0501.1996.070204.x
  • 22
    Degidi M, Nardi D, Daprile G, Piattelli A. Nonremoval of immediate abutments in cases involving subcrestally placed postextractive tapered single implants: a randomized controlled clinical study. Clin Implant Dent Relat Res. 2014 Dec;16(6):794-805. http://dx.doi.org/10.1111/cid.12051 PMid:23458566.
    » http://dx.doi.org/10.1111/cid.12051
  • 23
    Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study. Bone. 2005 Dec;37(6):776-80. http://dx.doi.org/10.1016/j.bone.2005.06.019 PMid:16154396.
    » http://dx.doi.org/10.1016/j.bone.2005.06.019
  • 24
    Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont. 1998 Sep-Oct;11(5):408-20. PMid:9922733.
  • 25
    Trisi P, Perfetti G, Baldoni E, Berardi D, Colagiovanni M, Scogna G. Implant micromotion is related to peak insertion torque and bone density. Clin Oral Implants Res. 2009 May;20(5):467-71. http://dx.doi.org/10.1111/j.1600-0501.2008.01679.x PMid:19522976.
    » http://dx.doi.org/10.1111/j.1600-0501.2008.01679.x
  • 26
    Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res. 2001 Oct;12(5):423-32. http://dx.doi.org/10.1034/j.1600-0501.2001.120501.x PMid:11564101.
    » http://dx.doi.org/10.1034/j.1600-0501.2001.120501.x
  • 27
    Devlin H, Horner K, Ledgerton D. A comparison of maxillary and mandibular bone mineral densities. J Prosthet Dent. 1998 Mar;79(3):323-7. http://dx.doi.org/10.1016/S0022-3913(98)70245-8 PMid:9553887.
    » http://dx.doi.org/10.1016/S0022-3913(98)70245-8
  • 28
    Oliscovicz NF, Shimano AC, Marcantonio E Jr, Lepri CP, Dos Reis AC. Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque. Int J Dent. 2013;2013:194987. http://dx.doi.org/10.1155/2013/194987 PMid:23431301.
    » http://dx.doi.org/10.1155/2013/194987
  • 29
    Turkyilmaz I, Aksoy U, McGlumphy EA. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Clin Implant Dent Relat Res. 2008 Dec;10(4):231-7. http://dx.doi.org/10.1111/j.1708-8208.2008.00084.x PMid:18384409.
    » http://dx.doi.org/10.1111/j.1708-8208.2008.00084.x
  • 30
    Schwarz MS, Rothman SL, Rhodes ML, Chafetz N. Computed tomography: Part I. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants. 1987;2(3):137-41. PMid:3481354.
  • 31
    Ikumi N, Tsutsumi S. Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study. Int J Oral Maxillofac Implants. 2005 Mar-Apr;20(2):253-60. PMid:15839119.
  • 32
    Lundgren S, Anderson S, Gualini F, Sennerby L. Bone reformation with sinus membrane elevation: a new surgical technique for maxillary sinus floor augmentation. Clin Implant Dent Relat Res. 2004;6(3):165-73. http://dx.doi.org/10.1111/j.1708-8208.2004.tb00224.x PMid:15726851.
    » http://dx.doi.org/10.1111/j.1708-8208.2004.tb00224.x
  • 33
    Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci. 1998 Jun;106(3):721-64. http://dx.doi.org/10.1046/j.0909-8836..t01-6-.x PMid:9672097.
    » http://dx.doi.org/10.1046/j.0909-8836..t01-6-.x
  • 34
    Norton MR. The influence of insertion torque on the survival of immediately placed and restored single-tooth implants. Int J Oral Maxillofac Implants. 2011 Nov-Dec;26(6):1333-43. PMid:22167441.
  • 35
    De Bruyn H, Raes S, Ostman PO, Cosyn J. Immediate loading in partially and completely edentulous jaws: a review of the literature with clinical guidelines. Periodontol 2000. 2014 Oct;66(1):153-87. http://dx.doi.org/10.1111/prd.12040 PMid:25123767.
    » http://dx.doi.org/10.1111/prd.12040
  • 36
    Moraschini V, Porto Barboza E. Immediate versus conventional loaded single implants in the posterior mandible: a meta-analysis of randomized controlled trials. Int J Oral Maxillofac Surg. 2016 Jan;45(1):85-92. http://dx.doi.org/10.1016/j.ijom.2015.07.014 PMid:26259980.
    » http://dx.doi.org/10.1016/j.ijom.2015.07.014
  • 37
    Benic GI, Mir-Mari J, Hammerle CH. Loading protocols for single-implant crowns: a systematic review and meta-analysis. Int J Oral Maxillofac Implants. 2014;29(Suppl):222-38. http://dx.doi.org/10.11607/jomi.2014suppl.g4.1 PMid:24660200.
    » http://dx.doi.org/10.11607/jomi.2014suppl.g4.1
  • 38
    Huwais S, Meyer EG. A novel osseous densification approach in implant osteotomy preparation to increase biomechanical primary stability, bone mineral density, and bone-to-implant contact. Int J Oral Maxillofac Implants. 2017 Jan/Feb;32(1):27-36. http://dx.doi.org/10.11607/jomi.4817 PMid:27741329.
    » http://dx.doi.org/10.11607/jomi.4817

Publication Dates

  • Publication in this collection
    16 Dec 2022
  • Date of issue
    2022

History

  • Received
    20 Nov 2022
  • Accepted
    21 Nov 2022
Universidade Estadual Paulista Júlio de Mesquita Filho Rua Humaitá, 1680 - Caixa Postal 331, 14801-903 Araraquara,São Paulo,SP, Tel.: (55 16) 3301-6376, Fax: (55 16) 3301-6433 - Araraquara - SP - Brazil
E-mail: adriana@foar.unesp.br