Acessibilidade / Reportar erro

Anatomical variation of radial wrist extensor muscles: a study in cadavers

Abstract

OBJECTIVE: The tendons of the extensor carpi radialis longus and brevis muscles are quite useful in tendon transfer, such as in correction of finger clawing and restoration of thumb opposition. Knowledge of additional radial wrist extensor muscle bellies with independent tendons is useful in the above-mentioned surgical procedures. METHODS: The skin, subcutaneous tissue, and antebrachial fascia of 48 (24 on the right side and 24 on left side) male upper limb forearms were dissected. The following aspects were then analyzed: (a) the presence of additional muscle bellies of radial wrist extensors, (b) the origin and insertion of the additional muscle, and (c) measurements of the muscle bellies and their tendons. RESULTS: Five out of 48 upper limbs (10.41%) had additional radial wrist extensors; this occurred in 3 out of 24 left upper limbs (12.5%) and 2 out of 24 right upper limbs (8.3%). In one of the right upper limbs, two additional muscles were found. The length and width of each additional muscle belly and its tendon ranged between 2 - 15cm by 0.35 - 6.4cm and 2.8 - 20.8cm by 0.2 0.5cm, respectively. The additional radial wrist extensor tendons in our study basically originated either from the extensor carpi radialis longus or brevis muscles and were inserted at the base of the 2nd or 3rd metacarpal bone. CONCLUSION: The present study will inform surgeons about the different varieties of additional radial wrist extensors and the frequency of their occurrence.

Extensor carpi radialis longus; Extensor carpi radialis brevis; Occurrence; Tendon transfer; Clinical significance


BASIC RESEARCH

Anatomical variation of radial wrist extensor muscles: a study in cadavers

Soubhagya Ranjan Nayak; Ashwin Krishnamurthy; Latha Venkatraya Prabhu; Rajalakshmi Rai; Anu Vinod Ranade; Sampath Madhyastha

Kasturba Medical College, Department of Anatomy, CBS, Bejai Mangalore - Karnataka, India. ranjanbhatana@gmail.com

ABSTRACT

OBJECTIVE: The tendons of the extensor carpi radialis longus and brevis muscles are quite useful in tendon transfer, such as in correction of finger clawing and restoration of thumb opposition. Knowledge of additional radial wrist extensor muscle bellies with independent tendons is useful in the above-mentioned surgical procedures.

METHODS: The skin, subcutaneous tissue, and antebrachial fascia of 48 (24 on the right side and 24 on left side) male upper limb forearms were dissected. The following aspects were then analyzed: (a) the presence of additional muscle bellies of radial wrist extensors, (b) the origin and insertion of the additional muscle, and (c) measurements of the muscle bellies and their tendons.

RESULTS: Five out of 48 upper limbs (10.41%) had additional radial wrist extensors; this occurred in 3 out of 24 left upper limbs (12.5%) and 2 out of 24 right upper limbs (8.3%). In one of the right upper limbs, two additional muscles were found. The length and width of each additional muscle belly and its tendon ranged between 2 - 15cm by 0.35 - 6.4cm and 2.8 - 20.8cm by 0.2 0.5cm, respectively. The additional radial wrist extensor tendons in our study basically originated either from the extensor carpi radialis longus or brevis muscles and were inserted at the base of the 2nd or 3rd metacarpal bone.

CONCLUSION: The present study will inform surgeons about the different varieties of additional radial wrist extensors and the frequency of their occurrence.

KEYWORDS: Extensor carpi radialis longus. Extensor carpi radialis brevis. Occurrence. Tendon transfer. Clinical significance.

INTRODUCTION

The extensor carpi radialis longus (ECRL) and brevis (ECRB) are two muscles that belong to the radial wrist extensors (RWE). The ECRL arises from the distal third of the lateral supracondylar ridge of the humerus and the adjacent portion of the lateral intermuscular septum, while the ECRB arises from the front of the lateral epicondyle of the humerus and the fascia covering the common extensor origin. Both of these radial extensors run through the 2nd compartment of the extensor retinaculum; the ECRL is inserted into the base of the second metacarpal bone, and the ECRB is inserted into the third1. According to a study conducted by Caetano et al. (2004) the most common pattern of the ECRL and ECRB was one muscle and one tendon each. Out of 60 upper limbs, they found additional RWE tendons in only 3 hands (all in relation to the ECRL tendon). The presence of an accessory tendon connecting the tendons of the ECRL and ECRB was identified in 4 dissected hands2. Albright and Linburg (1978) found that 26% of upper limbs had an accessory tendon joining the tendons of the ECRL and ECRB. The occurrence rate of an additional RWE was 24% in the same study (42 out of 173 upper limbs), and the additional muscles originated from either the ECRL or ECRB muscles3.

The importance of tendon transfer using RWE in opponensplasty and correction of finger clawing has been reported by several authors4-6. Cooney et al. (1984) studied various muscles to achieve effective tendon transfer for median nerve palsy. They found the ECRL muscle to be one of the best at approximating the force and motion required to restore lost thumb flexion, full thumb opposition and strength both in high and low median nerve palsy4. Baek et al. (1999) used either the ECRL or ECRB to restore opposition of the thumb. Out of the 11 transfers they performed, 10 gave excellent results5. Studies on the RWE were undertaken by various authors3, 7-13. Wood (1988) described the presence of additional RWE that could be used successfully for thumb opposition by motoring the flexor pollicis longus and extensor pollicis longus of the thumb12. The additional RWE tendons in our study were inserted into the dorsal digital expansion of the index finger (DDEIF), the base of the second metacarpal bone (B2M), the base of the third metacarpal bone (B3M), the base of both the second and third metacarpal bones (B2/3M) and the ECRB. In the past decade, unusual forms of RWE have been mentioned in the literature14-17. The purpose of the present study was to identify the occurrence and various forms of additional RWE. This knowledge should help surgeons to reduce their error in diagnosis and treatment in and around the radial wrist extensors when additional muscle bellies and their tendons exist. This work was motivated by the paucity of literature regarding the origin of additional RWE and their immense importance in tendon transfers.

MATERIALS AND METHODS

During routine cadaver dissection in the Department of Anatomy, Kasturba Medical College, Mangalore, India, we dissected 24 formalin-embalmed male (47-75) upper limbs during the academic years, 2004-2005 and 2005-2006. The skin, superficial fascia, and antebrachial fascia from the lateral aspect of the forearms were then excised, and the individual RWE were studied for the presence of any additional muscles. When identified, anatomical description of the additional RWE was achieved by measuring its length, width and attachments. Measurements of the additional muscles and their tendons were done with the help of a Vernier caliper in centimeters (cm).

RESULTS

Out of 48 upper limbs studied, five (10.41%) had additional RWE (Fig 1, 2, 3a, 3b, 4, 5). Three out of 24 left upper limbs (12.5%) and 2 out of 24 right upper limbs (8.3%) had additional RWE. In one of the right upper limbs, there were two additional muscles found (Fig 3a, 3b). The length and width of each additional muscle belly and its tendon are mentioned in Table 1.







Anatomical variation 1

The additional muscle took its origin from the ECRB and then passed between the ECRB and extensor digitorum communis (EDC) in the forearm. Its tendon ran below the extensor retinaculum, along with the tendons of the EDC and extensor indicis in the fourth dorsal osseofibrous tunnel, and was inserted into the DDEIF. The tendon of the EDC to the IF was absent in the above case (Fig 1). The length and width of the additional muscle belly and tendon were 11.4 cm by 1.3 cm and 15 cm by 0.25 cm, respectively.

Anatomical variation 2

The additional muscle took a tendinous origin from the lateral epicondyle of the humerus (LEH), between the origin of the ECRB and EDC muscles, and was on the medial side of the ECRL and ECRB muscles. Fifteen centimeters from its origin, the muscle divided into two tendons below the abductor pollicis longus (APL) and extensor pollicis brevis (EPB) muscles. The upper tendon then traveled side by side with the tendon of the ECRB muscle and passed through the second dorsal osseofibrous tunnel to be inserted into the B2M, medial to the insertion of the ECRB tendon. The lower tendon crossed over the ECRL tendon and also passed through the second dorsal osseofibrous tunnel to be inserted into the radial side of the B3M, above the insertion of ECRL (Fig 2). The length and width of the additional muscle bellies and tendons were 15 cm by 6.4 cm for the upper and lower muscle bellies, 10.2 cm by 0.5 cm for the upper tendon and 10.5 cm by 0.45 cm for the lower tendon.

Anatomical variation 3a

The additional muscle took its origin from the ECRB, between the ECRB and ECRL muscles. The tendon of the additional muscle was placed between the ECRB and ECRL tendons in the second dorsal osseofibrous tunnel and was inserted between the B2/3M (Fig 3a). The length and width of the additional muscle belly and tendon were 3 cm by 1.1 cm and 19.4 cm by 0.3 cm, respectively.

Anatomical variation 3b

The additional muscle took its origin from the undersurfaces of both the ECRL (medial) and brachioradialis (BR), then formed a common muscle and was inserted on the upper surface of the ECRB tendon (Fig 3b). The length of the additional muscle belly was 2 cm from the BR and 2.5 cm from the ECRL, while the width was 0.5 cm from the BR and 0.6 cm from the ERCL. The length and width of the additional muscle tendon were 2.8 cm and 0.4 cm, respectively.

Anatomical variation 4

The additional muscle took its origin from the radial side of the ECRL, and the tendon passed below the APL and EPB muscles to be inserted on the undersurface of the ECRB tendon (Fig 4). The length and width of the additional muscle belly and tendon were 6.2cm by 0.35 cm and 12.8 cm by 0.2 cm, respectively.

Anatomical variation 5

The additional muscle took its origin from the radial side of the ECRL, and the tendon passed below the second dorsal osseofibrous tunnel to be inserted into the B3M (Fig 5). The length and width of the additional muscle belly and tendon were 2 cm by 0.4 cm and 20.8 cm by 0.3 cm, respectively.

DISCUSSION

The extensor carpi radialis intermedius (ECRI) and extensor carpi radialis accessories (ECRA) are the two previously described variants of additional RWE in the antebrachial region (Wood, 1867 as cited by Wood, 1988; Wood, 1867 as cited by MacAlister, 1871)7,8,12. In the present study, we found that the additional RWE originated from the ECRL in three cases, from the ECRB in two cases, and from the BR and LEH in one case each. The additional RWE tendons inserted into various sites on the dorsal aspect of the hand, namely the DDEIF, B2M, B3M, B2/3M and the tendon of the ECRB muscle. The length of the additional RWE varied from two to 15 cm, and the muscle width also varied from 0.35 to 6.4 cm. The tendon length of the additional RWE varied from 2.8 to 20.8 cm, and the tendon width also varied from 0.2 to 0.5 cm. All of the additional RWE tendons were large enough to perform a tendon transfer.

Wood (1988)12 examined 312 upper limbs and found 39 (12.5%) ECRI, of which 32 (10.25%) tendons were suitable for muscle transfer and 7 (2.24%) were unacceptable. In the present study, we identified the occurrence of additional RWE in 10.41% of upper limbs, which was similar to the study by Wood (1988)12. Albright and Linburg (1978) 3 studied 173 upper limb specimens, of which they found 42 limbs (24%) with an extra muscle that originated either from the ECRL or ECRB muscle. In the present study we found additional RWE in 10.41% of upper limbs in comparison to the 24% found by Linburg (1978)3. Although the origins of additional RWE were mainly from the ECRL and ECRB, we also noted origins from the LEH and BR.

Baek et al. (1999)5 used ECRL and ECRB tendons instead of the flexor digitorum profundus (FDP) tendon to restore thumb opposition. To their surprise, they found that the RWE tendons produced excellent results. Malaviya (2003)6 used split ECRL tendons to correct finger clawing and was able to reduce operating time, muscle herniation and scarring at the donor site. Cooney et al. (1984)4 studied forearm and hand muscle volume, mean fiber length, and cross-sectional area for tendon transfers done for opposition of thumb and found that 60% of ECRL tendons were effective. Sabapathy et al. (2005)18 found that ECRL tendon transfer for restoration of finger flexion in patients with flexor muscle loss was a simple alternative, which should be considered when possible.

The present study on RWE supplements knowledge about the various forms of additional RWE and their occurrence. Furthermore, the morphometric measurements of the additional muscles and their tendons will help surgeons performing tendon transfer in the antebrachial and carpal region.

CONCLUSION

In the present study, we found five anatomical variations in the radial wrist extensor muscles. The length and width measurements of the anatomical variations were considered sufficient to warrant their use for tendon transfers.

Received for publication on September 11, 2007

Accepted for publication on October 05, 2007

  • 1. William PL, Warwick R, Dyson M, Bannister LH. The muscles of the fore arm. Gray's Anatomy. 37th ed. Edinburgh: Churchill Livingstone; 1989. p. 622.
  • 2. Caetano FM, Albertoni MW, Caetano BE, Perez MR. Anatomical study of insertions of the extensor carpi radialis longus and brevis. Int J Morphol. 2004;22:245-51.
  • 3. Albright JA, Linburg RM. Common variations of the radial wrist extensors. J Hand Surg. 1978; 3:134-8.
  • 4. Cooney WP, Linscheid RL, An KN. Opposition of the thumb: an anatomical and biomechanical study of tendon transfers. J Hand Surg. 1984;9:777-86.
  • 5. Baek GH, Jung JM, Yoo WJ, Chung MS. Transfer of extensor carpi radialis longus or brevis for opponensplasty. J Hand Surg. 1999;24:50- 3.
  • 6. Malaviya GN. Radial half of extensor carpi radialis longus tendon as graft to elongate muscle tendon unit for correction of finger clawing. Plast Reconstr Surg. 2003;111:1914-7.
  • 7. Wood J. Variations in human myology observed during the winter session of 1866-67 at King's College London. Proc. R. Soc. 1867;15:518-46.
  • 8. MacAlister A. Additional observations on muscular anomalies in human anatomy with a catalogue of the principal muscular variations hitherto published (third series). Trans. R. Ir. Acad. 1871;25:101-2.
  • 9. Frohse F, Frankel M. Die Muskeln des menschlichen Armes. In: Bardeleben, Kv. (Ed.), Handbuchs der Anatomie des Menschen. Fischer, Jena, 1908. p. 160-1.
  • 10. Valentin P. Extrinsic muscles of the hand and wrist: an introduction. In: Tubiana, R. (Ed.), The Hand. Philadelphia: WB Saunders Company; 1981. p. 243.
  • 11. Kaplan EB, Spinner M. Important muscular variations of the hand and forearm. In: Spinner, M. (Ed.), Kaplan's Functional and Surgical Anatomy of the Hand., Philadelphia: JB Lippincott Company; 1984. p. 340-1.
  • 12. Wood VE. The extensor carpi radialis intermedius tendon. J Hand Surg. 1988;13:242-5.
  • 13. Yoshida Y. Anatomical studies on the extensor carpi radialis longus and brevis muscles in Japanese. Okajimas Folia Anat Jpn. 1994;71:127-35.
  • 14. Melling M, Steindl M, Wilde J, Karimian-Teherani D. An anatomical variant of the extensor carpi radialis brevis muscle. Wien Klin Wochenschr. 2001;113:960-3.
  • 15. Mitsuyasu H, Yoshida R, Shah M, Patterson RM, Viegas SF. Unusual variant of the extensor carpi radialis brevis muscle: a case report. Clin Anat. 2004;17:61-3.
  • 16. Hong MK, Hong MK. An uncommon form of the rare extensor carpi radialis accessorius. Ann Anat. 2005;187:89-92.
  • 17. Nayak SR, Madhan Kumar SJ, Krishnamurthy A, Prabhu LV, Ranade AV, Rai R et al. An additional radial wrist extensor and its clinical significance. Ann Anat. 2007;189:283-6.
  • 18. Sabapathy SR, Gowda DK, Ranade AB, Venkatramani H, Sebastin SJ. Functional outcome of extensor carpi radialis longus transfer for finger flexion in posttraumatic flexor muscle loss. J Hand Surg. 2005;30:267- 72.

Publication Dates

  • Publication in this collection
    13 May 2008
  • Date of issue
    2008

History

  • Accepted
    05 Oct 2007
  • Received
    11 Sept 2007
Faculdade de Medicina / USP Rua Dr Ovídio Pires de Campos, 225 - 6 and., 05403-010 São Paulo SP - Brazil, Tel.: (55 11) 2661-6235 - São Paulo - SP - Brazil
E-mail: clinics@hc.fm.usp.br