Acessibilidade / Reportar erro

Changing Trends in the Treatment of Mandibular Fracture

Excluding nasal fractures, mandibular fractures are the most common fractures of the facial bones. A functioning intact mandible is essential for biting, chewing and speaking.11 Kumar I, Singh V, Bhagol A, Goel M, Gandhi S. Supplemental maxillomandibular fixation with miniplate osteosynthesis-required or not? Oral Maxillofac Surg 2011;15(01):27-30

The first description of a mandibular fracture dates back to 1650 BC, and an Egyptian papyrus describes the examination, diagnosis and treatment of mandibular fractures. Hippocrates was the first to mention the reapproximation and immobilization of the fractured mandible utilizing circumdental wires and external bandaging. The importance of first establishing proper dental occlusion was highlighted in the textbook written by Roger of Salerno in Italy in 1180. Rigid maxillomandibular fixation (MMF) was first mentioned in 1492, in an edition of the book Cirugia, which was printed in Lyons, France. Moreover, rigid internal fixation was developed and popularized by Spiessel in Europe in 1970s.22 Spiessl B. Rigid internal fixation of fractures of the lower jaw. Reconstr Surg Traumatol 1972;13:124-140 33 Ellis E III, Miles BA. Fractures of the mandible: a technical perspective. Plast Reconstr Surg 2007;120(07, Suppl 2):76S-89S

The purposes of the treatment of mandibular fractures are to restore the pre-trauma dental occlusion and normal mouth opening and to reduce the displaced fracture.44 El-Anwar MW, Sayed El-Ahl MA, Amer HS. Open reduction and internal fixation ofmandibular fracturewithout rigid maxillomandibular fixation. Int Arch Otorhinolaryngol 2015;19(04):314-318

Open reduction/internal fixation (OR/IF) has dramatically revolutionized the approach to mandible fractures, minimizing the postoperative role of rigid MMF. But MMF is still used to maintain proper occlusion until the IF of the fracture is performed.44 El-Anwar MW, Sayed El-Ahl MA, Amer HS. Open reduction and internal fixation ofmandibular fracturewithout rigid maxillomandibular fixation. Int Arch Otorhinolaryngol 2015;19(04):314-318 55 Gupta R, Surayana S, Pandya VK, et al. Traumatic mandibular fractures: Pendulum swinging towards closed reduction? World Articles of Ear, Nose, and Throat 2010;3:1 66 Haug RH, Assael LA. Outcomes of open versus closed treatment of mandibular subcondylar fractures. J OralMaxillofac Surg 2001;59 (04):370-375, discussion 375-376

Traditionally, closed reduction and OR/IF using wire osteosynthesis require an average of 6 weeks of immobilization by MMF in order to achieve satisfactory healing. Negative sequelae associated with this extended period of immobilization include airway problems, poor nutrition, weight loss, poor oral hygiene, speech difficulties, social inconvenience, insomnia, patient discomfort, work difficulties, and difficulty in retrieving the normal opening range of the jaw. In contrast, rigid and semirigid fixation of the mandible fractures enables early mobilization and restoration of normal jaw mobility, improved nutritional status, improved speech and oral hygiene, patient comfort and an early return to work.77 Singh B, Bhardwaj V. Continuous mandibular nerve block for pain relief. A report of two cases. Can J Anaesth 2002;49(09):951-953 88 Nacamuli RP, LongakerMT. Bone induction in craniofacial defects. Orthod Craniofac Res 2005;8(04):259-266

Immediate postoperative release of the rigid MMF after OR/IF using titanium miniplate(s) was confirmed to be as effective and safe as maintaining postoperative rigid MMF for different durations.55 Gupta R, Surayana S, Pandya VK, et al. Traumatic mandibular fractures: Pendulum swinging towards closed reduction? World Articles of Ear, Nose, and Throat 2010;3:1 66 Haug RH, Assael LA. Outcomes of open versus closed treatment of mandibular subcondylar fractures. J OralMaxillofac Surg 2001;59 (04):370-375, discussion 375-376 However, the use of rigid intraoperative MMF increases the operative time, cost, blood-transmitted diseases to patients and/or the surgical team and the risk of tooth injury. These factors opened the door for recent studies searching for simpler, faster, easier and at the same time effective OR/IF of the fractured mandible.44 El-Anwar MW, Sayed El-Ahl MA, Amer HS. Open reduction and internal fixation ofmandibular fracturewithout rigid maxillomandibular fixation. Int Arch Otorhinolaryngol 2015;19(04):314-318

After a prospective comparative study, El-Anwar et al44 El-Anwar MW, Sayed El-Ahl MA, Amer HS. Open reduction and internal fixation ofmandibular fracturewithout rigid maxillomandibular fixation. Int Arch Otorhinolaryngol 2015;19(04):314-318 found that manual MMF (3MF) during the OR/IF of selected cases of mandibular fractures could be successfully performed, allowing for a more rapid and less complex procedure limited to the mandible. In addition to the gained benefits of immediate postoperative mandible mobilization, 3MF provided significantly shorter operative times (p< 0001), less risk of blood-transmitted diseases to the surgical team and the patient, and significantly better early mouth opening (p= 0.0015).

In a later study of the the advantages of the rapid 3MF procedure that is limited to the mandible, El-Anwar and Hegab99 El-Anwar MW, Hegab A. Internal fixation of single mandibular fracture under mandibular nerve block. Oral Maxillofac Surg 2016;20(01):57-61 were the first to investigate the 3MF repair of fractured mandibles under regional anesthesia comparing the results with a control group in which 3MF was performed under general anesthesia (GA). They used an extraoral mandibular nerve block, and concluded that regional anesthesia can replace GA in the OR/IF of selected cases of mandibular fracture (parasymphyseal fracture) without reported complications, providing an optimal solution when GA is not recommended or contraindicated.

More studies applying regional anesthesia in other types of mandibular fracture are expected to be conducted in the near future. The maxillofacial surgeons' awareness of those easier and reliable alternatives needs to be increased so these simpler and effective repairs become more popular.

When there is a need to maintain a postoperative rigid MMF, various methods have been employed over time. Even though arch bars are effective for rigid MMF, they are not devoid of negative aspects. Intermaxillary fixation (IMF) screws are similarly effective for rigid MMF regarding postoperative occlusion and MMF stability. Additionally, IMF screws have the advantages of decreasing the surgical time and gloves perforations, and of enabling better patient acceptance and oral hygiene. Accidental root perforation is the only limitation to IMF screws.1010 Qureshi AA, ReddyUK,WaradNM, Badal S, Jamadar AA, Qurishi N. Intermaxillary fixation screws versus Erich arch bars in mandibular fractures: A comparative study and review of literature. Ann Maxillofac Surg 2016;6(01):25-30

The treatment of mandibular angle fractures represents a challenge due to their higher rate of complications, and there is currently no agreement as to the optimal treatment. The percutaneous approach using the transbuccal trocar technique provides easy access and fixation of the screws. Recently, El-Anwar and Sweed1111 El-Anwar MW, Sweed AH. Simple percutaneous transbuccal approach for management of mandibular angular fracture. J Craniofac Surg 2017;28(04):1035-1037 described a new, effective and simple percutaneous transbuccal approach using a modified cover of the cannula as a disposable available trocar for the admission and conduction of a microdrill shaft and screw driver directly to the fracture.

The familiarity with and popularity of these simpler effective trends in mandibular fracture repair will be very beneficial for surgeons, patients and the community in general.

References

  • 1
    Kumar I, Singh V, Bhagol A, Goel M, Gandhi S. Supplemental maxillomandibular fixation with miniplate osteosynthesis-required or not? Oral Maxillofac Surg 2011;15(01):27-30
  • 2
    Spiessl B. Rigid internal fixation of fractures of the lower jaw. Reconstr Surg Traumatol 1972;13:124-140
  • 3
    Ellis E III, Miles BA. Fractures of the mandible: a technical perspective. Plast Reconstr Surg 2007;120(07, Suppl 2):76S-89S
  • 4
    El-Anwar MW, Sayed El-Ahl MA, Amer HS. Open reduction and internal fixation ofmandibular fracturewithout rigid maxillomandibular fixation. Int Arch Otorhinolaryngol 2015;19(04):314-318
  • 5
    Gupta R, Surayana S, Pandya VK, et al. Traumatic mandibular fractures: Pendulum swinging towards closed reduction? World Articles of Ear, Nose, and Throat 2010;3:1
  • 6
    Haug RH, Assael LA. Outcomes of open versus closed treatment of mandibular subcondylar fractures. J OralMaxillofac Surg 2001;59 (04):370-375, discussion 375-376
  • 7
    Singh B, Bhardwaj V. Continuous mandibular nerve block for pain relief. A report of two cases. Can J Anaesth 2002;49(09):951-953
  • 8
    Nacamuli RP, LongakerMT. Bone induction in craniofacial defects. Orthod Craniofac Res 2005;8(04):259-266
  • 9
    El-Anwar MW, Hegab A. Internal fixation of single mandibular fracture under mandibular nerve block. Oral Maxillofac Surg 2016;20(01):57-61
  • 10
    Qureshi AA, ReddyUK,WaradNM, Badal S, Jamadar AA, Qurishi N. Intermaxillary fixation screws versus Erich arch bars in mandibular fractures: A comparative study and review of literature. Ann Maxillofac Surg 2016;6(01):25-30
  • 11
    El-Anwar MW, Sweed AH. Simple percutaneous transbuccal approach for management of mandibular angular fracture. J Craniofac Surg 2017;28(04):1035-1037
  • Financial Support

    The author received no financial support to write this letter.

Publication Dates

  • Publication in this collection
    Jul-Sep 2018

History

  • Received
    05 Apr 2017
  • Accepted
    24 Aug 2017
Fundação Otorrinolaringologia R. Teodoro Sampaio, 483, 05405-000 São Paulo/SP Brasil, Tel.: (55 11) 3068-9855, Fax: (55 11) 3079-6769 - São Paulo - SP - Brazil
E-mail: iaorl@iaorl.org