INTRODUCTION
Acrylic resin is one of the most widely used dental materials for fabricating dental prostheses1. The transitional phase is of great importance to prosthetic treatment as it deals with the simulation of the definitive prosthesis2. This material is composed of a liquid-powder system in which the powder is composed of methyl polymethacrylate (polymer) and the liquid is composed of methyl methacrylate (monomer). There are two types of acrylic resin: autopolymerizing (or chemically activated) and heat-polymerizing (heat-activated).
The type of acrylic resin processing can affect the mechanical properties and surface roughness. The polymerized acrylic resin structure has a number of free monomers between 3% and 5% in the autopolymerizing version and 0.1% in the heat-polymerizing form1. The presence of these free monomers has an impact on surface roughness and complicates the resin finishing and polishing process.
A greater accumulation of biofilm is frequently observed on irregular surfaces and also causes discomfort to the patient. The biofilm, considered to be a bacterial microcolony, adheres to irregular surfaces in the mouth and they grow, forming a continuous layer of bacteria that adversely affects dental structures and oral tissue3. The accumulated biofilm is related to the etiology of diseases such as dental caries and periodontal diseases4. Accordingly, prosthetic work needs to have a smooth, well-finished surface in order to minimize the accumulation of bacteria. According to Kasina et al.5, a porous prosthetic part is vulnerable to exogenous coloration, the deposition of tartar and adhering substances. Thus, for a prosthetic appliance to be hygienically acceptable, it must not be porous. The fabrication of temporary crowns is a hugely important step in prosthetic treatment, mainly in the case of lengthy treatment. Among other characteristics, the temporary element should not retain biofilm as this may cause constant inflammation of the gums, thereby hindering the clinical stages for the production of the definitive crown.
In view of this, in order to avoid the loss of prosthetic pillars and adjacent teeth to periodontal disease or caries, smooth well-finished parts are extremely important, in addition to making the element esthetically acceptable6-7. Thus, finishing and polishing techniques need to be established reconciling the use of accessible materials, reduction in clinical time and the attainment of less surface roughness6.
Accordingly, in order to achieve adequate surface smoothness, there are two forms of finishing and polishing that are most commonly used in clinical practice. The more conventional method is the finishing and polishing done with the use of maxicut and minicut burs, mounted stones, a mandrel with fabric sandpapers and grinding wheels (with pumice stone and water) and cotton sandpaper (with Spanish white and water). At the present time, the use of the Dhpro® Finishing and Polishing Kit is the recommended option, which has rubber tips (silicone) and rotary brushes (Scotch Brite - goat-hair, cotton or felt) with a sequence of use recommended by the manufacturer.
Although autopolymerizing acrylic resin is widely used in the fabrication of temporary restorations, there is little information in the literature about the effect of certain finishing and polishing techniques on surface texture or on which resins the techniques produce the best results. In view of this, the present study was proposed with the aim of analyzing surface roughness of samples prepared with two commercial brands of autopolymerizing resin, applying two finishing and polishing methods, ascertaining which method is most effective for each type of resin.
METHODS
In this experiment, classified as a controlled in vitro experimental study, two brands of autopolymerizing acrylic resin were used that are widely employed in the fabrication, repair and relining of temporary crowns, namely:
- Clássico Dencor® 62
- Duralay® 62
Fabrication of test specimens
In the course of this study, in order to obtain the specimens, aluminum expulsion molds were fabricated measuring 65x12mm at the top, 64x11mm at the base and with a thickness of 3.5mm8. A quantity of Zetalabor® - Zhermak Condensation Silicon was put in a plastic container and molds were produced from the aluminum dies. The acrylic resins were manipulated using the proportions recommended by the manufacturer. During the plastic phase (working phase) the resins were accommodated, with the use of finger pressure, in the condensation silicone molds. Once completely polymerized, the specimens were removed from the molds. Twenty test specimens were fabricated (10 of each make) and each was split down the middle, each half receiving a different type of finishing and polishing (Figure 1).
Finishing and polishing techniques
The method considered to be conventional, which has the following sequence: tungsten grinders (Maxicult); cylindrical carborundum mounted stone; 180 grit sandpaper for wood finishing in 10 mm strips, mounted on a mandrel; fabric disc on a lathe using a mixture of pumice stone and water as the abrasive; lastly, cotton disc on a lathe with “Spanish white” polisher and water;
Dhpro® finishing and polishing kit comprising: Maxicut (for greater abrasion), Minicut (for smaller degree of abrasion), a reasonable amount of abrasion with rubber tips (Grey → Green → Yellow), Scotch Brite wheel (to remove scratches), goat-hair brush, felt wheel (goat-hair brush and felt wheel are both used with the FotoAcrill® paste that comes with the kit) and, lastly, the cotton brush is used to remove excess paste.
Each stage of the finishing and polishing methods lasts 10 seconds.
Data acquisition and statistical analysis
The fabrication of the test specimens and the finishing and polishing procedures listed above were carried out by a single operator. The test specimens were subsequently subjected to an evaluation of surface roughness using the Taylor Hobson Surtronic 25 roughness tester, in the technology center in the Metrology laboratory at the Rio Grande do Norte Federal University, providing 40 sets of roughness results, each result composed of three arithmetic mean readings. The readings were taken perpendicularly to the direction of the finishing and polishing. The data collected in the roughness test were subjected to the Student’s t-test.
RESULTS
In the t-test, a significant difference was found between conventional polishing and the polishing with the DhPro® kit (Figure 2 / p < 0.001), but this discrepancy is not related to the make of the resins. Table 1 shows that the makes of acrylic resin, when compared, and without taking into account the type of polishing, possess similar mean roughness values. By analyzing the best polishing for each make of acrylic resin, the conventional method was shown to be superior (Figure 3).
Table 1 Roughness, correlating the two makes of resin (Clássico Dencor® and Duralay®).
Type of Resin | N | Mean (µm) | Std. Deviation | “t” | “p” |
Roughness | Clássico Dencor | 20 | 0.16500 | 0.063398 | 0.052 0.959 |
Duralay | 20 | 0.16635 | 0.096309 |
DISCUSSION
The interrelationship between the transitional and definitive stages of fixed prosthetic treatment is very significant2. For this reason, temporary prostheses should be perfectly in accordance with what is desired of the definitive prosthesis. In view of this, the surface of these temporary restorations should be polished to avoid accumulation of biofilm, as well as to provide comfort for the patient and be esthetically acceptable7.
A number of authors devised a roughness classification in which they determined the range from 0.7 µm to 3.4 µm as the values of low roughness9. Accordingly, all surface roughness values obtained using the techniques of finishing and polishing used in the present study can be considered low, as the surface roughness values found varied between 0.08 µm and 0.48 µm. On the other hand, Quirynem & Bollen et al.10 stated that the roughness value below which bacterial adherence should not be expected, thus making the prosthesis clinically acceptable, is 0.2 μm. Consequently, it can be shown that the mean values of roughness exhibited in this study, for both types of polishing, and mainly with conventional polishing as it achieved lower mean values, should not generate an accumulation of microorganisms.
Mesquita et al.11 evaluated the effect on surface roughness of conventional and chemical polishing on heat-activated and autopolymerizing acrylic resin specimens. The results confirmed that conventional polishing was more effective than chemical polishing in reducing roughness. Several authors reported that chemical polishing on autopolymerizing acrylic resin structures causes softening of the less polymerized structures, caused by the monomer used in this type of polishing12. The advantage of this type of polishing is the speed and ease of execution, but it is seen to be less effective than mechanical methods13.
Another form of mechanical polishing employed by dental surgeons is to use Sof Lex® (3M) discs. When compared to methods such as rubber cup + Vaseline; pumice stone + Spanish White on a polishing lathe; 150 grit grinding discs for mandrel, the Sof Lex® (3M) discs produced the best results in reducing surface roughness, with a mean value of 0.48 µm14. This demonstrates the superior efficiency of the methods employed in this study, principally the conventional method.
The time taken to complete the polishing was evaluated, showing that, although many easy-to-use finishing and polishing kits are available, the method which takes the least amount of time, conventional polishing with a mechanical lathe, is superior4.