Abstracts
Flexural strength of high performance concrete submitted to several non-standard curing conditions was evaluated through bending tests on beams in order to allow comparisons among different curing procedures. The moist curing process resulted more effective than curing by chemical products leading to membrane formation over concrete surface; moreover, flexural strength of high strength concrete was increased when satu- rated specimens were tested, whereas conventional concrete flexural strength decreased when submitted to the same conditions. Such results were explained on the basis of concrete porosity with the support of air permeability tests. Results explained differences between the behavior of conventional and high strength concrete when water fills the specimen pores. As recommendation, high strength concrete specimens shall not be tested in bending in saturated condition under the risk of overestimation of flexural resistance.
flexural strength; curing; porosity
Um concreto de elevada resistência recebeu diferentes tipos de cura em laboratório e testes de resistência à tração na flexão permitiram comparar os resultados devidos aos diferentes processos de cura. A cura úmida resultou bem mais eficiente que a cura com aspersão de produto químico formando membrane sobre a superfície do concreto.; mais importante, a resistência à flexão dos concretos de elevada resistência aumentou quando o corpo de prova estava saturado enquanto que para concretos convencionais de pavimentação essa resistência diminuiu com a saturação das amostras. Com base em testes de permeabilidade ao ar para ambos os concretos, buscou-se explicar a natureza do fenômeno encontrado, consid- erando as gritantes diferenças na estrutura de poros de ambos os concretos. Como principal recomendação, a medida de resistência à tração na flexão para concretos de elevada resistência não deve ser realizada com amostras saturadas dados os resultados irreais encontrados
resistência à tração na flexão; cura; porosidade
Influence of curing procedures and porosity in the flexural resistance of concretes for paving
Influência do método de cura e da porosidade na resistência à tração na flexão de concretos para pavimentação
T.C. CervoI; J.T. BalboII; M. BadawyIII; A.A. SeveriIV
IUniversidade Federal de Santa Maria, tcervo@terra.com.br,tcervo@terra.com.br, Av. Roraima, 1000, Camobi, CT, Dpto de Transportes, 97105-900, Santa Maria, RS, Brasil
IIUniversidade de São Paulo, Epusp, jotbalbo@usp.br,jotbalbo@usp.br, Av. Prof. Almeida Prado 82, Cidade Universitária, 05508-900, São Paulo, Brasil
IIITFB A.G., badawy@bluenet.ch,badawy@bluenet.ch, Lindenstrasse 10, CH-5103, Wildegg, Suíça
IVECOWORLD, aseveri@gmail.com,aseveri@gmail.com, Rua Jacurici 166, 01453-030, São Paulo, Brasil
ABSTRACT
Flexural strength of high performance concrete submitted to several non-standard curing conditions was evaluated through bending tests on beams in order to allow comparisons among different curing procedures. The moist curing process resulted more effective than curing by chemical products leading to membrane formation over concrete surface; moreover, flexural strength of high strength concrete was increased when satu- rated specimens were tested, whereas conventional concrete flexural strength decreased when submitted to the same conditions. Such results were explained on the basis of concrete porosity with the support of air permeability tests. Results explained differences between the behavior of conventional and high strength concrete when water fills the specimen pores. As recommendation, high strength concrete specimens shall not be tested in bending in saturated condition under the risk of overestimation of flexural resistance.
Keywords: flexural strength, curing, porosity.
RESUMO
Um concreto de elevada resistência recebeu diferentes tipos de cura em laboratório e testes de resistência à tração na flexão permitiram comparar os resultados devidos aos diferentes processos de cura. A cura úmida resultou bem mais eficiente que a cura com aspersão de produto químico formando membrane sobre a superfície do concreto.; mais importante, a resistência à flexão dos concretos de elevada resistência aumentou quando o corpo de prova estava saturado enquanto que para concretos convencionais de pavimentação essa resistência diminuiu com a saturação das amostras. Com base em testes de permeabilidade ao ar para ambos os concretos, buscou-se explicar a natureza do fenômeno encontrado, consid- erando as gritantes diferenças na estrutura de poros de ambos os concretos. Como principal recomendação, a medida de resistência à tração na flexão para concretos de elevada resistência não deve ser realizada com amostras saturadas dados os resultados irreais encontrados
Palavras-chave: resistência à tração na flexão; cura; porosidade.
Texto completo disponível apenas em PDF.
Full text avaliable only in PDF.
6. References
Received: 22 Oct 2009
Accepted: 23 Nov 2010
Available Online: 28 Nov 2011
- [01] Tan, K; Gjorv, O. E. Performance of concrete under different curing conditions. Cement and Concrete Research, vol. 26, n. 3, pp. 355-361, 1996.
- [02] Ewertson, C.; Petersson, P.E. The influence of curing conditions on the permeability and durability of concrete. Results from a field exposure test. Cement and Concrete Research, vol. 23, pp. 683-692, 1993.
- [03] Raithby, K.D.; Galloway, J.W. Effects of moisture condition, age, and rate of loading on fatigue of plain concrete. Proceedings of ABELES Symposium on Fatigue of Concrete, Hollywood, ACI Publication, v. 41, pp. 15-34, 1974.
- [04] Gräf, H. and Grube, H. Verfahren zur prüfung der Durchlässigkeite von mörtel und beton gegenüber gasen und wasser. Beton, Helft 5, 1986.
- [05] Badawy, M and Honegger, E. Swissmetro – test on air permeability of concrete. Proceedings of the 16th Congress of IABSE, Cd-rom, Lucern, 2002.
Publication Dates
-
Publication in this collection
18 Sept 2014 -
Date of issue
Dec 2010
History
-
Received
22 Oct 2009 -
Accepted
23 Nov 2010