Acessibilidade / Reportar erro

Steel and concrete bond stress: a contribution to the study of APULOT tests using concrete with rubber addition

Abstracts

The bond stress between steel and concrete is the essential condition to the good behaviour of reinforced concrete structures. To preview the use of concrete with waste incorporation for structural aims, the verification of its quality control is necessary, whether of compression strength and bond. This paper presents the study results about the viability use of APULOT tests, that is a bond tests, to prevent the compression strength of concrete with rubber addition. The purpose of APULOT tests become study in many laboratories in France and Brazil, where is to estimate the compression strength using the bond stress obtained in tests execute inside of building construction. Also the use of concrete with rubber addition to structural use has been made with safe because this kind of addition makes the concrete compression strength decrease. To study its compression strength behavior is also make part of this research. This work aims to contribute with standardization of APULOT tests, and also give conditions to use the concrete with rubber addition in structural elements with more safe.

bond stress; compression strength; concrete; rubber


A aderência entre o concreto e o aço (armadura) é o principal fator do bom desempenho do concreto armado. Para prever a utilização do concreto com incorporação de resíduos para fins estruturais, a verificação do controle de qualidade se faz necessária, quer seja de sua resistência à compressão axial quer seja de sua aderência. Este artigo apresenta os resultados do estudo sobre a viabilidade do ensaio de aderência aço-concreto, denominado ensaio APULOT, para estimativa da resistência à compressão axial do concreto com adição de fibras de borracha. A proposta do ensaio APULOT, vem sendo estudada em vários laboratórios de pesquisa, na França e no Brasil e consiste em determinar a resistência à compressão axial do concreto, a partir dos resultados da tensão de aderência realizados na obra. A utilização do concreto com incorporação de resíduos de borracha para fins estruturais deve ser feita com cautela, pois comprovadamente a adição de borracha no concreto faz com que a resistência à compressão do mesmo venha a diminuir. Estudar seu comportamento quanto à resistência axial à compressão, além da aderência aço e concreto, também é necessária. Este trabalho visa contribuir com a normalização do ensaio APULOT possibilitando um melhor controle tecnológico em canteiros de obra, assim como verificar as condições de utilização para fins estruturais do concreto com resíduos de borracha.

tensão de aderência; resistência à compressão; concreto; borracha


Steel and concrete bond stress: a contribution to the study of APULOT tests using concrete with rubber addition

A. E. P. G. De Avila Jacintho ; L. L. Pimentel; M. P. Barbosa; P. S. P. Fontanini

Pontifícia Universidade Católica de Campinas, Faculdade de Engenharia Civil, Campinas, SP, Brasil E-mail: anajacintho@puc-campinas.edu.br, lialp@puc-campinas.edu.br, monica.barbosa@puc-campinas.edu.br, pspucha@puc-campinas.edu.br

ABSTRACT

The bond stress between steel and concrete is the essential condition to the good behaviour of reinforced concrete structures. To preview the use of concrete with waste incorporation for structural aims, the verification of its quality control is necessary, whether of compression strength and bond. This paper presents the study results about the viability use of APULOT tests, that is a bond tests, to prevent the compression strength of concrete with rubber addition. The purpose of APULOT tests become study in many laboratories in France and Brazil, where is to estimate the compression strength using the bond stress obtained in tests execute inside of building construction. Also the use of concrete with rubber addition to structural use has been made with safe because this kind of addition makes the concrete compression strength decrease. To study its compression strength behavior is also make part of this research. This work aims to contribute with standardization of APULOT tests, and also give conditions to use the concrete with rubber addition in structural elements with more safe.

Keywords: bond stress, compression strength, concrete, rubber.

1. Introduction

There are several ways to perform quality control on a reinforced concrete work, such as project management, molds, shoring, and one of the essential aspects for this control lies in monitoring the effectiveness of the concrete material, once the steel has an extremely strict control in its manufacture.

In most countries, the current technological control of reinforced concrete works is based almost exclusively on the testing of axial compression strength in concrete specimens, cubic or cylindrical, which are usually casted upon receipt of the concrete at the construction site prior to launching into the molds. This type of test, standardized in Brazil by ABNT NBR 5739:2007 [1] requires appropriate equipments and trained manpower, available at registered civil engineering laboratories. Only then this strength parameter is obtained to determine the efficiency of structural elements.

However, this testing disadvantage is the fact that the laboratories specialized for its implementation are often distant from the construction sites, as well as the need for controlling a number of factors such as molding, storing, capping and specimen loading velocity. Besides these facts, the axial compression strength test is done on a single material, the concrete, ignoring the bond between the steel and the concrete, essential condition for the existence of reinforced concrete. The steel already has a strict control on its manufacture, thus the need for mechanical strength testing is ignored in a work site.

Being aware of the importance and usefulness of the traditional test to determine the compression strength of concrete, a group of researchers led by Professor 3 Michel LORRAIN from INSA - Toulouse, has been analyzing the possibility of employing a bond test steel – concrete adapted to the construction site to estimate the concrete compression strength, due to experimental drawbacks obtained when performing these traditional tests.

This group has been working on the optimization of a new testing method featured by its simplicity and low cost, based on bond test steel-concrete pull-out- test, recommended by RILEM RC6: 1983 [2].

The method proposed by Lorrain and Barbosa (2008) [3] received the designation of APULOT (Appropriate pull-out test) and since its inception it has been tested in laboratories from various domestic and foreign universities (such as Ilha Solteira UNESP , UFRG, PUC – Campinas, INSA Toulouse, etc.), presenting good results and adequate capacity of estimated compression strength. Some tests performed on construction sites have also obtained satisfactory results.

The advantages of the proposed method reflect on the simplicity of its implementation, the reduction of the recommended time to perform the test, from 28 days to 7 days or even 3 days, besides the possibility of measuring not only strength but also the behavior of steel – concrete bonding, prime factor for the suitable performance of reinforced concrete structures.

This research, in the context presented, aims to contribute to the study of viability of the APULOT bond test as proposal of technological control and safety of reinforced concrete works, operating with a new range of concrete: the concrete with additions of residues. The search for alternative materials such as porcelain from electrical insulators, rubber tires, demolition waste, etc... that can be used in concrete, reducing the use of natural materials extracted from nature, such as river sand (fine aggregate) and crushed rock or boulder (aggregate coarse), has been growing in Brazil and the use of this concrete structural elements must be assessed in all its aspects, including its bonding to the steel bars.

Experimental tests were conducted to determine the compression strength of concrete with the addition of rubber fibers, both in the traditional method according NBR 5735:2007[4], and in the proposed new method, obtaining the compression strength from the APULOT test results.

1.1 Explanation

The main point of interest of this study is that the compression strength of the concrete is determining upon the behavior of steel-concrete bond. The hypothesis of the APULOT project is that if the test is conducted under controlled conditions and standardized, this relation becomes even more evident and robust, allowing an estimate of maximum compression strength of bonding. Added to this fact, evaluating the behavior of concrete incorporating residues in the partial or total replacement of conventional aggregates is justified by the need to review this new type of concrete for structural purposes.

2. The technological control of reinforced concrete

The quality of a product can be understood as the ability to meet certain requirements under the conditions of use foreseen. Thus, the quality control covers a set of operational techniques and activities undertaken, whose purpose is to ensure that the final product meets the pre-determined standards (Brandão, 1998) [5].

Quality control of a concrete structure is a wide and complex process, because it covers several variables ranging from planning, control of employee services to issues related with durability and lifespan of the structure.

Among these variables, the part of technological control applied in materials used in civil works, more specifically steel and concrete, is what most straightly interests for this work.

In the decades of 50 and 60, the evolving knowledge of concrete technology has treated concrete strength as a random magnitude, of normal distribution (Gaussian) of values and also as part of the structural variables. Fusco (2011) [6] states that this methodology has grown due to the advances in researches on structural calculation under breaking regime and the probability of structural variables.

Regarding steel the ABNT NBR 6118:2007 [7] prescribes that the parameters for quality control of the steel bars and wire designed for the reinforcement of concrete structures must meet the specifications of ABNT NBR 7480:2007 [8] .5 For quality control of the concrete designed to structures, the ABNT NBR 6118:2007 [7] states that parameters must meet the specifications of ABNT NBR 12655:2006 [9].

In hardened concrete, the main mechanical properties required by ABNT NBR 6118:2007 [7] are: compression strength (fc), modulus of elasticity (Ec) and tensile strength (fct).

The only test of steel-concrete bond recommended by Brazilian standards is regulated by ABNT NBR 7477:1982 [10], which determines the coefficient of superficial form coefficient (h) of the bars and steel wires.

The axial compression strength of concrete is the most commonly reported parameter and used for the technological control of the concrete. This value refers to the results of cylindrical specimens molded with concrete according to ABNT NBR 5738:2008 [11] and broken according to ABNT NBR 5739:2007 [1].

According to NBR 6118:2007 [7] for purposes of structural design of reinforced and prestressed concrete, from the compression strength it is possible to determine the modulus of elasticity and the tensile strength and even the bond stress for the anchoring of armors. According to Silva Filho and Helene (2011) [12] although the most recent norms and recommendations worldwide suggest to increase the number of parameters for quality control of concrete works, it is still traditional in Brazil to establish this control specifically on the compression strength of cylindrical specimens, molded during concreting.

2.1 Relation between steel-concrete bond with concrete compression strength

According to Fusco (1995) [13] the principle of structural concrete is the mutual action between steel-concrete which must comply with conditions allowing each one of them to reach the limits of their resisting capabilities without harming or being harmed by forces acting on one or other separated material. Being concrete a brittle material and of low resistance to tensile, and the steel being ductile and of high tensile strength, one material complements the other, thus forming reinforced or prestressed concrete, provided the condition of adhesion between the materials is met.

In the literature, several types of tests are found of assays for determining the bond stress between the steel bars and concrete and stress versus displacement curve. One of the most known and used, due to its efficiency, is the pull-out test (POT) which has its recommended guidelines in RILEM RC6: 1983 [2] and ASTM C234: 1996 [14].

A research conducted by Abrams (1913) [15] using pull-out bond tests found the influence of some variables inherent to the test response. Among these variables, the effect of mechanical strengths showed, no more than 100 years ago, there is a strong correlation between the compression strength of concrete and the maximum strength of steel-concrete bond. Later, in 1956, Rush studies [16] demonstrated the form importance in the steel-concrete strength, confirming a clear and strong correlation between the compression strength and the bond stress.

In NBR 6118: 2007 [7], the bond stress (τu) is given by the following equation:

Where : tu = Ultimate Bond Stress ;

F= pull out force;

ø = bar diameter;

L = Anchorage length.

The relationship between the bond stress and concrete compression strength is not explained in this equation. The proposal to relate the two parameters through a straight line, constructed empirically, was given in Lorrain and Barbosa (2008) [3]

3. APULOT test method

The main point of interest in the topic of this research is that the resistance of reinforced concrete is a key aspect for the bonding behavior. The principal concept of APULOT test is that if the bond test steel-concrete is conducted at controlled and standardized conditions this relationship becomes even more evident and robust, thus allowing the estimation of the concrete compression strength from the maximum bond strength data.

The APULOT test philosophy is to perform the reinforced concrete quality control from appropriate steel-concrete bond testing in the construction site, i.e., ascertain the compliance of the concrete compression strength ";in situ"; by means of bond strength through correlation between these respective strengths, proposed by Lorrain et al. [17].

The method is based on the principle of the POT (Pull out of a steel bar inserted into a concrete specimen) , however a PET bottle is used as mold, with the most homogeneous format possible in anchorage length, and a hydraulic jack, which is an equipment easily found in the working site. Figure 1 presents the APULOT test scheme.


For obtaining the anchorage length (Equation 4) the formulas of ultimate bond stress (Equation 1) and the yield stress of steel (Equation 2) are used. The value for the ultimate bond stress is obtained by the correlation proposed by Lorrain and Barbosa (2008) [3] (Figure 2).


It is important to note here that these suggested values of anchorage length in this experimental research are the first attempts of APULOT test characterization, so these values may be renewed with the advances in researches with these tests.

Where:

fy = Steel yield stress (MPa).

4. Steel and concrete bond stress with rubber addition

One of the researches conducted in Brazil on steel and concrete bond stress, using concrete with tire rubber residues was made by França (2004) [18] at UNESP of Ilha Solteira. He compared the bond stress obtained in pull out tests between conventional compression strength concrete of 35MPa to compression strength concrete with rubber residues of 25 MPa for ages of 28 and 90 days.

FRANÇA (2004) [18] compared his experimental results with other researchers and concluded that the concrete and rubber can be used in structures of reinforced concrete, despite the mechanical strengths not reaching very high values. The bond stress curves x bar slide had similar development between the conventional concrete and the concrete with rubber, conventional concrete and concrete with rubber, despite the concrete with rubber presenting bond stress with lower values.

Based on the findings from several studies already completed on the mechanical behavior of concrete with rubber Akasaki et al. (2003) [19] observed that the residues called rubber fibers may act as obstacles against crack development, when they intersect micro cracks which appear during the hardening of concrete, preventing its progression. Yet Yunping XI et al. (2004) [20] found that the concrete with rubber holds unique features with potential for using in several applications. According to Jacintho et al.(2010) [21] the concrete with rubber can be used in the manufacture of precast floor parts as an alternative for contributing to decrease the disposal of this material in landfills and to preserve non-renewable natural resources .

5. Materials and experimental program

The materials used in the experimental program of this research are from the Metropolitan Region of Campinas.

The experimental results regarding the particle size of the aggregates (rubber, sand and gravel) are shown in Tables 1, 2 and 3 and in figures 3, 4 and 5.




The rubber used in this study can be seen in Figure 6.


The experimental results of concrete with rubber, that is, their mechanical properties as well as their composition are presented in this section.

For this research the following materials were used: CP ARI RS cement type; Water from Campinas city water supply system; fine aggregate of quartz sand type; coarse aggregate: basalt stone; rubber: from scrap shredded tire; additive: multifunctional and steel: CA-50.

The following standards have been met: NBR5738 2003 [11] for the molding and hydration of Specimens; NBR5739: 2007 [1] for cylindrical concrete specimen compression test; NBR7222: 2011 [22] for determining the tensile strength by diametrical compression of cylindrical specimens; NBR12142: 2010 [23] for determining the flexural tensile strength in prismatic specimens; and NBR8522: 2008 [24] for determining modulus of elasticity test.

Initially, the concrete with rubber was studied in the proportion of 15% and 20%. A conventional concrete was made as a reference for comparing results. The fibers were added to the concrete with reference to the consumption of cement, not replacing anything concerning the reference concrete.

The specimens for testing compression strength, tensile strength by diametrical compression, and modulus of elasticity were cylindrical specimens of 10cm x 20cm and the specimens used in the tests of flexural tensile strength were prismatic ones measuring 15cm x 15cm x 50cm.

The results obtained from tests for axial compression strength, tensile strength by diametrical compression, flexural tensile strength and modulus of elasticity can be seen in Table 4. The graphs with average values in the tests cited in Table 4 can be seen in Figures 7-10 .


The characteristics of the steel found in this research were: yield stress fy = 583.0 MPa and rupture fu = 708.3 MPa. The diameter of the bars used was 8mm.

5.1 Analysis of results of mechanical characteristics of concrete

Through the graphs shown in Figures 7 to 10 and the average results presented in Table 4, it is observed a decrease in the values of the resistances and modulus of elasticity of concrete containing rubber when compared with the reference concrete, also observed by França [18] in different proportions from the ones assessed here.

Table 5 presents, briefly, in percentage, the decrease in the values of concrete strength in this research.

5.2 Pull out tests and procedures

After the initial tests of concrete strength, it was decided to make pullout tests with a percentage of rubber addition at the rate of 10%, for the fall in resistance has been accentuated for the 20% proportion of addition. Also because the 15% results have not eased this fall. The purpose was to try to get results of bond stress closer to the work performed by Granzotto [25] and by Jacintho et al [21].

This way, four concreting and four castings were made: one for the reference concrete, one for concrete with 10% of rubber addition, one for 15% and one for concrete with 20% rubber addition.

After molding, the specimens and PET bottles models were immersed in water, in the next day for hydration. One day before each test they were removed from the hydration, in order not to be tested in the saturated condition.

The anchorage length used for bars of 8mm diameter was 11 cm and was calculated using Equation 4, assuming the considerations of Equation 3, however using the steel rupture stress. This stress was chosen because the features of concrete with rubber have not been fully demonstrated, the bond length should be larger than the conventional one, since the concrete with rubber has less resistance than the usual concrete.

Tests with 7 and 14 days of age were performed to test cylindrical specimens measuring 10x20cm and tests with 14 days of age for models of molded PET bottles. At 7 days results for compressive strength of concrete and modulus of elasticity were obtained.

At 14 days the pullout tests of APULOT bars (figure 11) were performed and the following mechanical characteristics of concrete were also obtained: compression strength (Figure 12), tensile strength by diametral compression (Figure 13) and modulus of elasticity (Figure 14).





6. Results and partial discussion

The test results of compression strength, tensile strength by diametrical compression and modulus of elasticity can be seen in Table 6. Table 7 presents the results of the pullout tests.

For all the tests 8mm diameter bars and 11cm long anchorage were used 5 models were tested for each series of concrete, but some results were discarded for being very discrepant. For the series of reference concrete, a result was discarded, for the series of concrete added with 10% of rubber, 2 results were discarded and for the series of concrete with 20% rubber the result was not considered.

Figures 15-18 show graphs of bond stress X sliding obtained from tests.


Clique para ampliar

Clique para ampliar

Note that the higher the amount of rubber added to concrete, the lower the ultimate bond stress, however the branches of post-stress curves are shown flatter with respect to its slope. With the addition of 10% rubber, the loss of ultimate bond stress was not very sharp. This is due to the fact that the concrete with this amount of rubber had no significant loss in compression strength. On the contrary, its resistance ended up higher than the reference concrete. Even though the ultimate bond stress was lower than those found for the reference concrete.

Yet for the concrete with 15% rubber addition it is noted that the bond curve approach to the concrete with 10%, with a slight fall. When the addition of rubber into the concrete was 20%, the compression strength was smaller and the bond stress was ranked much lower levels, well below from the concrete with 10% and 15% addition.

In figure 19 it is presented the correlation between the bond stresses and the compression strengths obtained in the tests, with a linear interpolation between the points obtained. It can be noted that the results of concrete with addition of 20% rubber are more distant from the other concrete in the graph.


7. Conclusions

The analysis of the correlation between the maximum bond stress and compression strength brings to conclusion that the APULOT bond test is adequate to estimate the compression strength of the concrete at all ages tested. With the analysis of correlations it is possible to conclude that the increase of the maximum bond stress is proportional to increase the compression strength of the concrete.

A partial conclusion obtained in this work is classic in that the addition of rubber into the concrete causes a decrease in compression strength.

Another important conclusion was that the addition of the rubber into concrete also causes a decrease in the bond stress.

Therefore the values given for the calculation of the anchorage length for conventional concrete should be reviewed and increased so that when making the structural element using concrete with rubber, it was observed that for little additions into the concrete it can be performed.

An indication obtained in this research is that the values of this length of anchorage are proportional to the amount of rubber added to the concrete. Meanwhile, to reach the equation correlating the anchorage length with the amount of rubber added to concrete, more researches need to be conducted for a wider range of amounts of rubber added to the concrete.

8. Acknowledgment

The authors thank to the Fundação de Amparo à Pesquisa do Estado de São Paulo for the provided financial aid for this research could be realized.

They also thank to the staff of the Materials of Civil Construction and Structural laboratory, to the students Jonas Luís de Godoy and Ruy José Aun, of Pontifical Catholic University of Campinas for the help in the tests development and execution.

9. References

Received: 24 Feb 2014

Accepted: 15 Jul 2014

Available Online: 02 Oct 2014

  • 01. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 5739: Concreto Ensaio de compressão de corpos de prova cilíndricos. Rio de Janeiro, 2007.
  • 02. COMITÊ EURO-INTERNACIONAL DU BÉTON: RILEM/CEB/FIB/RC6.Concrete Reinforcement Technology. Paris, Georgi Publishing Company, 1983 
  • 03. LORRAIN, M.; BARBOSA, M.P. Controle de qualidade dos concretos estruturais: Ensaio de aderência aço-concreto. Revista Concreto e Construções. n.51, pp. 52-57. jul, ago, set, 2008.
  • 04. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 5735: Cimento Portland de alto-forno, Rio de janeiro, 2007
  • 05. BRANDÃO, A.M.S. Qualidade e durabilidade das estruturas de concreto armado:aspectos relativos ao projeto, 1998. 137f. Dissertação (Mestrado em Engenharia de estruturas) Escola de Engenharia de São Carlos, São Carlos, 1998.
  • 06. FUSCO, P.B. , Princípios Básicos para Projeto de Estruturas de Concreto. In: IBRACON - instituto Brasileiro do Concreto. (Org.). CONCRETO: CIÊNCIA E TECNOLOGIA. 1 ed. São Paulo: Ipsis Gráfica e Editora, 2011, v. 1, p. 101-126.
  • 07. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Projeto de estruturas de concreto – Procedimento. NBR 6118, Rio de Janeiro, 2007.
  • 08. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 7480: Aço destinado a armaduras para estruturas de concreto armado. Especificações. Rio de janeiro, 2007.
  • 09. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 12655: Concreto de cimento Portland - Preparo, controle e recebimento – Procedimento, Rio de Janeiro, 2006.
  • 10
     ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 7477: Determinação do coeficiente de conformação superficial de barras e fios de aço destinados a armaduras de concreto armado, Rio de Janeiro, 1982.
  • 11
     ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Concreto – Procedimento para moldagem e cura dos corpos de prova. NBR 5738, Rio de Janeiro, 2008.
  • 12. SILVA FILHO,L.C.P.; HELENE,P. Análise de estruturas de concreto com problemas de resistência e fissuração. In.: ISAIA G.C., Concreto: Ciência e Tecnologia. 1Edição. São Paulo: Editora IBRACON, 2011. vol.2, cap. 32, p 1124-1174.
  • 13. FUSCO, P. B. Técnica de armar as estruturas de concreto. São Paulo: PINI, 1995, 265p.
  • 14
     American Standardization for Testing and Materials (ASTM) C 234 91a – Standard test method for comparing concretes on the basis of the bond developed with reinforcing steel. 1996.
  • 15. ABRAMS, D.A.,";Test of Bond Between Concrete And Steel,";Engineering Experiment Station, Bulletin No. 71, University of Illinois, Champaign, 1913.
  • 16. RÜSCH,H. Der Zusammenhang zwischen rissbildung und Haftfestigkeit unter besonderer Berücksichtigung der Anwendung hoher Stahlspannungen. In: Stüssi,F.;Lardy,P. (Hrsg.) Fifih Congress (Lisboa-Porto), Preliminary publication. Lisboa; IABSE,1956, S. 791-813.
  • 17. LORRAIN, M.; BARBOSA, M.P.; ARNAUD M.. Bond test and on-site structural concrete quality control. 3rd fib International Congress 2010. Anais. EUA. 2010.
  • 18. FRANÇA, V. H. Aderência aço-concreto uma análise do comportamento do concreto fabricado com resíduos de borracha. Dissertação de Mestrado. UNESP de Ilha Solteira. 2004.
  • 19. AKASAKI, J. L.; SERNA ROS, P.; REYES, B.; TRIGO, A. P. M.. Avaliação da Resistência à Flexão do Concreto com Borracha de Pneu com Relação ao Concreto Convencional. In: 45º Congresso Brasileiro do Concreto. Anais. Vitória, E. S., IBRACON, 2003.
  • 20. YUNPING XI, YUE LI, ZHAOHUI XIE, AND JAE S. LEE. Utilization of solid wastes (waste glass and rubber particles) as aggregates in concrete. In: International Workshop on Sustainable Development And Concrete Technology. pp.45-54, 2004.
  • 21. JACINTHO, Ana Elisabete P. G. A.; CAMPOS, Wendersen C.; PIMENTEL, Lia L. Concreto com adição de fibras de borracha: um estudo frente às resistências mecânicas. In: 52º Congresso Brasileiro do Concreto, Fortaleza, 2010.
  • 22
     ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Concreto e argamassa – Determinação da resistência à tração por compressão diametral de corpos de prova cilindricos. NBR 7222, Rio de Janeiro, 2011.
  • 23
     ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS.  Concreto – Determinação da resistência à tração na flexão de corpos de prova prismáticos. NBR 12142, Rio de Janeiro, 2010.
  • 24
     ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS.  Concreto – Determinação do módulo estático de elasticidade à compressão. NBR 8522, Rio de Janeiro, 2008
  • 25. GRANZOTTO, l. Concreto com adições de borracha: uma alternativa ecologicamente viável. Dissertação de Mestrado, Universidade Estadual de Maringá, UEM, 2010.
  • Publication Dates

    • Publication in this collection
      27 Oct 2014
    • Date of issue
      Oct 2014

    History

    • Received
      24 Feb 2014
    • Accepted
      15 July 2014
    IBRACON - Instituto Brasileiro do Concreto Instituto Brasileiro do Concreto (IBRACON), Av. Queiroz Filho, nº 1700 sala 407/408 Torre D, Villa Lobos Office Park, CEP 05319-000, São Paulo, SP - Brasil, Tel. (55 11) 3735-0202, Fax: (55 11) 3733-2190 - São Paulo - SP - Brazil
    E-mail: arlene@ibracon.org.br