Acessibilidade / Reportar erro

Analysis of biodegradation of orthodontic brackets using scanning electron microscopy

Abstracts

OBJECTIVES: The purpose of this study was to analyze, with the aid of scanning electron microscopy (SEM), the chemical and structural changes in metal brackets subjected to an in vitro biodegradation process. METHODS: The sample was divided into three groups according to brackets commercial brand names, i.e., Group A = Dyna-Lock, 3M/Unitek (AISI 303) and Group B = LG standard edgewise, American Orthodontics (AISI 316L). The specimens were simulated orthodontic appliances, which remained immersed in saline solution (0.05%) for a period of 60 days at 37°C under agitation. The changes resulting from exposure of the brackets to the saline solution were investigated by microscopic observation (SEM) and chemical composition analysis (EDX), performed before and after the immersion period (T0 and T5, respectively). RESULTS: The results showed, at T5, the formation of products of corrosion on the surface of the brackets, especially in Group A. In addition, there were changes in the composition of the bracket alloy in both groups, whereas in group A there was a reduction in iron and chromium ions, and in Group B a reduction in chromium ions. CONCLUSIONS: The brackets in Group A were less resistant to in vitro biodegradation, which might be associated with the type of steel used by the manufacturer (AISI 303).

Corrosion; Biocompatibility; Orthodontic brackets; Nickel


OBJETIVO: analisar, por meio de microscopia eletrônica de varredura, as alterações químicas e estruturais de braquetes metálicos submetidos a um processo de biodegradação in vitro. MÉTODOS: a amostra foi dividida em dois grupos, de acordo com a marca comercial dos acessórios - Grupo A = Dyna-Lock, 3M/Unitek (AISI 303) e Grupo B = LG Edgewise Standard, American Orthodontics (AISI 316L). Os corpos de prova, aparelhos ortodônticos simulados, permaneceram imersos em solução salina (0,05%) por um período de 60 dias, a 37ºC, sob agitação. As alterações decorrentes da exposição dos acessórios à solução salina foram investigadas através da observação com microscópio eletrônico de varredura (MEV) e análise da composição química (EDX), realizadas antes e após o período de imersão (T0 e T5, respectivamente). RESULTADOS: em T5, houve formação de produtos de corrosão sobre a superfície dos braquetes, especialmente no Grupo A, além disso, houve alterações na composição da liga metálica dos braquetes de ambos os grupos, sendo que, no Grupo A, houve redução dos íons ferro e cromo e, no Grupo B, redução de íons cromo. CONCLUSÃO: os acessórios do Grupo A apresentaram-se menos resistentes à biodegradação in vitro, o que poderia estar associado ao tipo de aço utilizado em sua fabricação (AISI 303).

Corrosão; Biocompatibilidade; Braquetes ortodônticos; Níquel


ONLINE ARTICLE

IPhD in Orthodontics, Federal University of Rio de Janeiro (UFRJ). Professor, Master's Program in Orthodontics, School of Dentistry, Rio Grande do Sul Catholic University (PUCRS)

IIMSc in Orthodontics and Facial Orthopedics, PUCRS

IIIPhD in Engineering, Head of the Centre for Microscopy and Microanalysis, PUCRS

Contact address

ABSTRACT

OBJECTIVES: The purpose of this study was to analyze, with the aid of scanning electron microscopy (SEM), the chemical and structural changes in metal brackets subjected to an in vitro biodegradation process.

METHODS: The sample was divided into three groups according to brackets commercial brand names, i.e., Group A = Dyna-Lock, 3M/Unitek (AISI 303) and Group B = LG standard edgewise, American Orthodontics (AISI 316L). The specimens were simulated orthodontic appliances, which remained immersed in saline solution (0.05%) for a period of 60 days at 37°C under agitation. The changes resulting from exposure of the brackets to the saline solution were investigated by microscopic observation (SEM) and chemical composition analysis (EDX), performed before and after the immersion period (T0 and T5, respectively).

RESULTS: The results showed, at T5, the formation of products of corrosion on the surface of the brackets, especially in Group A. In addition, there were changes in the composition of the bracket alloy in both groups, whereas in group A there was a reduction in iron and chromium ions, and in Group B a reduction in chromium ions.

CONCLUSIONS: The brackets in Group A were less resistant to in vitro biodegradation, which might be associated with the type of steel used by the manufacturer (AISI 303).

Keywords: Corrosion. Biocompatibility. Orthodontic brackets. Nickel.

Editor's summary

The occurrence of hypersensitivity caused by the nickel present in stainless steel alloys-widely used in orthodontic treatment-has become increasingly common. Orthodontic brackets, bands and archwires are universally made from this alloy, which contains about 6% to 12% nickel and 15% to 22% chromium. Besides allergenicity, carcinogenic, mutagenic and cytotoxic effects have been attributed to nickel and, to a lesser extent, chromium. One of the factors that determine the biocompatibility of alloys used in dentistry is their resistance to corrosion. However, despite the high resistance of austenitic stainless steel-the major alloy employed in the manufacture of orthodontic brackets-several studies have revealed the corrosion of these brackets. In view of the wide array of factors associated with corrosion and the susceptibility of orthodontic brackets to this process, the purpose of this study was to analyze, using scanning electron microscopy (SEM), the chemical and structural changes in two brands of metal brackets subjected to a process of biodegradation in vitro.

Two different brackets were analyzed: Dyna-Lock Standard Edgewise (3M Unitek, Monrovia, CA, USA) and LG Edgewise (American Orthodontics, Sheboygan, Wisconsin, USA), which were divided into 2 experimental groups, according to their commercial brand names. For evaluation by SEM (Philips XL30, Eindhoven, Netherlands) 70 brackets were randomly selected and analyzed in two stages: T0 - analyzed "as received" and T5 - after 60 days immersion in saline. The specimens were immersed in test tubes containing 10 ml of saline solution (NaCl 0.05%, Biochemistry Department, PUCRS) and subjected to a process of chemical-mechanical aging. They remained under agitation for 8 hours a day at a constant temperature of 36±1ºC (Dubnoff Bath, Nova Técnica™) for a period of up to 60 days.

The microscopic analysis (SEM) at T0 indicated that the brackets in Group A had a better surface finish than those of Group B. Alterations were found on the surfaces of the brackets after a 60-day immersion in saline solution (T5). These changes were more evident in Group A. As shown in Figures 2 and 3, differences were found in the composition of the metal alloy used in the brackets before (T0) and after having remained 60 days immersed in saline solution (T5). The brackets in Group A showed a reduction in the amount of iron and chromium (p < 0.05) and the brackets in Group B showed a decrease in chromium ions (p < 0.05).


FIGURE 1




It should be underscored that the use of alloys with a lower biodegradation rate would reduce the risk of harm to patient health.

Questions to the authors

1) How did you develop an interest in this subject matter?

Biocompatibility began to arouse our interest because of a patient who showed an allergic reaction to the metal in his cervical headgear. At the time, the patient came to the office reporting urticaria and rash in the neck area. A clinical examination revealed an erythematous area with vesicles in the neck and with injuries on both sides, in the same size and location of the headgear metal parts. The patient's medical history disclosed allergy to non-gold earrings, which caused local inflammation and skin peeling. Thus, contact dermatitis was diagnosed. The treatment consisted in removing the stimulus (replacement of the cervical headgear by a new one with no metal contact with the skin). Fifteen days later, the patient returned with no signs of allergic reaction.1 Since then we began to study, by means of in vitro2 and in vivo3-8 studies, the causes and consequences of the organic reactions which can manifest themselves in local or distant regions of the human body. One of the determinants of biocompatibility of metallic alloys in dentistry is the resistance to corrosion.6 Corrosion is defined as metal loss or oxidation. In the humid environment of the oral cavity all alloys undergo corrosion, at least to a certain extent.9 A number of factors can affect the process of ion release by an alloy: Manufacturing method; bracket surface characteristics; features of the environment in which brackets are inserted, such as composition, temperature, pH, bacterial flora, enzyme activity and the presence of proteins;10 in addition to factors such as alloy usage (aging), which may be subject to adverse conditions such as stress, heat treatment, recycling or reuse of components, among others.11

2) What can be done to reduce the biodegradation of metal brackets?

First, we should use good quality materials to minimize corrosion effects. The use of recycled brackets should be avoided. This issue was investigated by assessing the patterns of ion release by new brackets and recycled stainless steel brackets. To this end, the brackets were immersed in solutions with different pH values over a period of 48 weeks. The release of nickel, chromium, iron, copper, cobalt and manganese ions was analyzed by atomic absorption spectrophotometry. The results showed that recycled brackets release more ions than new brackets. This study demonstrates that although both new and recycled brackets will suffer corrosion in the oral environment,12 the cleaning and sterilization procedures involved in the recycling process result in microstructural changes that increase corrosion. We must also consider the possibility of using alternative products, such as nickel-free brackets, ceramic, titanium, polycarbonate or gold plated brackets.

3) Would it be important to evaluate the cytotoxicity of chemical agents released in the corrosion of steel brackets?

Material biocompatibility entails an appropriate response by the host (organism), which, in dentistry, means the non-occurrence of adverse reactions, or the occurrence of tolerable adverse reactions of the organism to the presence of a given material.14 The occurrence of any adverse reaction is what we call toxicity. On the other hand, cytotoxicity, or assessment of toxicity in cell culture, is a complex in vivo phenomenon, which can manifest a wide range of effects, from simple cell death to metabolic aberrations, whereby cell death does not occur, but rather changes in cell function.15

The literature contains a wealth of studies focusing on metal ion release by orthodontic brackets-especially iron, chromium and nickel, the main stainless steel corrosion products. However, other metal ions present in the silver solder used in orthodontic appliances-such as cadmium, copper and zinc-may be released into the oral cavity. These are considered potentially hazardous chemicals, included in the list of substances and processes considered of high risk to human life. In a study on ion release and silver solder cytotoxicity, Freitas7 observed high toxicity of this material in fibroblasts, reflecting changes in cell adhesion, proliferation and growth. Additionally, it was found a significant release of silver solder ions, with high concentrations occurring immediately after appliance installation. These ions were, in descending order, copper, silver, zinc and cadmium, involving a risk of absorption and retention of these ions by the human body.

An in vitro study by Kerosuo, Moe and Kleven16 found that there seems to occur detectable release of nickel and chromium from orthodontic appliances, with the largest amounts being released under dynamic conditions. Even so, the estimated amount of nickel release of a complete orthodontic appliance is less than 10% of the amount consumed in our daily diet17 and can be considered negligible from a toxicological standpoint.16 Barrett, Bishara and Quinn17 emphasize the need to determine the quantity of these corrosion products that is actually absorbed by the patient. Bergman et al18 pointed out that they had no information on when the dissolution of nickel alloy begins, nor when the maximum concentration of nickel occurs in various tissues. They also have no knowledge of the pattern or dynamics of nickel release, and the uptake and excretion of nickel by the organism.3 The real effects of nickel on the functioning of organs and tissues exposed to it is still unknown. Despite several studies, many questions still remain unanswered, pointing to the need for further research on this issue.

REFERENCES

  • 1. Menezes LM, Souza FL, Bolognese AM, Chevitarese O. Reação alérgica em paciente ortodôntico: um caso clínico. Ortodontia Gaúcha. 1997;1(1):51-6.
  • 2. Dolci GS, Menezes LM, Souza RM, Dedavid BA. Biodegradação de braquetes ortodônticos: avaliação da liberação iônica in vitro. Rev Dental Press Ortod Ortop Facial. 2008 maio-jun;13(3):77-84.
  • 3. Menezes LM, Campos LC, Quintão CC, Bolognese AM. Hypersensitivity to metals in orthodontics. Am J Orthod Dentofacial Orthop. 2004;126:58-64.
  • 4. Menezes LM, Quintão CA, Bolognese AM. Urinary excretion levels of nickel in orthodontic patients. Am J Orthod Dentofacial Orthop. 2007;131:635-8.
  • 5. Westphalen GH, Menezes LM, Pra D, Garcia GG, Schmitt VM, Henriques JA, et al. In vivo determination of genotoxicity induced by metals from orthodontic appliances using micronucleus and comet assays. Genet Mol Res 2008;7:1259-66.
  • 6. Souza RM, Menezes LM. Nickel, chromium and iron levels in the saliva of patients with simulated fixed orthodontic appliances. Angle Orthod. 2008;78:345-50.
  • 7. Freitas MPM. Toxicidade da solda de prata utilizada em Ortodontia: estudo in vitro e in situ. [dissertação]. Porto Alegre: Pontifícia Universidade Católica do Rio Grande do Sul; 2008.
  • 8. Menezes LM, Freitas MPM, Gonçalves TS. Biocompatibilidade dos materiais em Ortodontia: mito ou realidade? Rev Dental Press Ortod Ortop Facial. 2009 mar-abr;14(2):144-57.
  • 9. Stenman E, Bergman M. Hypersensitivity reactions to dental materials in a referred group of patients. Scand J Dent Res. 1989;97(1):76-83.
  • 10. Staffolani N, Damiani F, Lilli C, Guerra M, Staffolani NJ, Belcastro S, et al. Ion release from orthodontic appliances. J Dent. 1999;27(6):449-54.
  • 11. Huang TH, Yen CC, Kao CT. Comparison of ion release from new and recycled orthodontic brackets. Am J Orthod Dentofacial Orthop. 2001;120(1):68-75.
  • 12. Huang TH, Ding SJ, Min Y, Kao CT. Metal ion release from new and recycled stainless steel brackets. Eur J Orthod. 2004;26:171-7.
  • 13. Von Fraunhofer JA. Corrosion of orthodontic devices. Semin Orthod. 1997;3:198-205.
  • 14. Schmalz G, Browne RM. The biological evaluation of medical devices used in dentistry: the influence of the European Union on the preclinical screening of dental materials. Int Dent J. 1995;45(4):275-8.
  • 15. Estrela C. Metodologia científica. 2Ş ed. São Paulo: Artmed; 2005.
  • 16. Kerosuo H, Moe G, Kleven E. In vitro release of nickel and chromium from different types of simulated orthodontic appliances. Angle Orthod. 1995;65(2):111-6.
  • 17. Barrett RD, Bishara SE, Quinn JK. Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro. Am J Orthod Dentofacial Orthop. 1993 Jan;103(1):8-14.
  • 18. Bergman B, Bergman M, Magnusson B, Söremark R, Toda Y. The distribution of nickel in mice. An autoradiographic study. J Oral Rehabil. 1980;7(4):319-24.
  • Analysis of biodegradation of orthodontic brackets using scanning electron microscopy

    Luciane Macedo de MenezesI; Rodrigo Matos de SouzaII; Gabriel Schmidt DolciII; Berenice Anina DedavidIII
  • Publication Dates

    • Publication in this collection
      07 June 2010
    • Date of issue
      June 2010
    Dental Press International Av. Luís Teixeira Mendes, 2712 , 87015-001 - Maringá - PR, Tel: (55 44) 3033-9818 - Maringá - PR - Brazil
    E-mail: artigos@dentalpress.com.br