Acessibilidade / Reportar erro

In vitro cytotoxicity of self-curing acrylic resins of different colors

Abstracts

OBJECTIVE:

The aim of this study was to assess the in vitro cytotoxicity of acrylic resins of different colors over time.

METHODS:

Specimens were divided into 4 groups (n = 6) according to the color of the acrylic resin (Orto Class, Clássico, Campinas, São Paulo, Brazil): Group 1: clear acrylic resin; group 2: pink acrylic resin; group 3: blue acrylic resin and group 4: green acrylic resin. All specimens were fabricated according to the mass manipulation technique and submitted to mechanical polishing protocol. The control was performed with an amalgam specimen (C+), a glass specimen (C-) and cell control (CC). Specimens were immersed in Minimum Eagle's Medium (MEM) and incubated for 24 h at 37o C. The extracts from the experimental material were filtered and mixed with L929 fibroblast. Cytotoxicity was evaluated at 4 different times, 24, 48, 72 and 168 h. After contact, cells were incubated for 24 h and added to 100 µ of 0.01% neutral red dye. The cells were incubated for 3 h for pigment incorporation and fixed. Cells viability was determined by a spectroscopic (BioTek, Winooski, Vermont, USA) with a 492-nm wavelength λ=492 nm).

RESULTS:

There were no statistical differences between the experimental groups and the CC and C- groups.

CONCLUSION:

Clear, pink, blue and green self-curing acrylic resins fabricated by means of the mass manipulation technique and mechanically polished are not cytotoxic. Neither the pigment added to the self-curing acrylic resin nor the factor of time influenced the cytotoxicity of the material.

Acrylic resins; Cell culture techniques; Cytotoxins


OBJETIVO:

avaliar, in vitro, a citotoxicidade de resinas acrílicas autopolimerizáveis, de diferentes cores, ao longo do tempo.

MÉTODOS:

os corpos de prova foram divididos em quatro grupos (n = 3), de acordo com a cor da resina acrílica utilizada (Orto Class, Clássico, São Paulo/SP), sendo: grupo 1, acrílica incolor; grupo 2, acrílica rosa; grupo 3, acrílica azul; e, grupo 4, acrílico verde. Todos os corpos de prova foram confeccionados pela técnica de massa e polidos mecanicamente. Um corpo de prova de amálgama, um de vidro e célula constituíram o controle positivo (C+), controle negativo (C-), e controle de célula (CC), respectivamente. Em seguida, esses foram imersos em meio mínimo essencial de Eagle (MEM) por 24h, quando se removeu o sobrenadante e colocou-os em contato com fibroblastos L929. Avaliou-se a citotoxicidade em quatro períodos: 24, 48, 72 e 168h. Após o contato com o meio, as células foram incubadas por 24h e adicionou-se 100µ do corante vermelho neutro a 0,01%. Posteriormente, as células foram incubadas por 3h, para incorporação do corante, e fixadas. A contagem das células viáveis foi realizada em espectrofotômetro (BioTek, Winooski, EUA), com um comprimento de onda de 492nm (λ = 492nm).

RESULTADOS:

não houve diferença estatística entre os grupos experimentais e os grupos CC e C-.

CONCLUSÇÕES:

as resinas acrílicas autopolimerizáveis incolor, rosa, azul e verde, manipuladas pela técnica de massa e polidas mecanicamente não são citotóxicas. O corante utilizado em resinas autopolimerizáveis e tempo não influenciam na citotoxocidade do material.

Resinas acrílicas; Técnicas de cultura de células; Citotoxinas


INTRODUCTION

Chemically activated acrylic resins are widely used in the fabrication of fixed, removable and retention orthodontic appliances.44. Gonçalves TS, Menezes LM, Silva LE. Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. Angle Orthod. 2008;78(4):722-7. Resin is sold in two vials: one containing the powder, the polymer, and the other containing the liquid, the monomer. The monomer is a clear, flammable and volatile liquid at room temperature.11. Aydin O, Attila G, Dogan A, Aydin MV, Canacankatan N, Kanik A. The effects of methyl methacrylate on nasal cavity, lung, and antioxidant system (an experimental inhalation study). Toxicol Pathol. 2002;30(3):350-6. It is considered cytotoxic and possibly genotoxic.99. Jorge JH, Giampaolo ET, Machado AL, Vergani CE. Cytotoxicity of denture base acrylic resins: a literature review. J Prosthet Dent. 2003;90(2):190-3. , 1010. Kedjarune U, Charoenworaluk N, Koontongkaew S. Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. Aust Dent J. 1999;44(1):25-30. , 2222. Schweikl H, Schmalz G, Spruss T. The induction of micronuclei in vitro by unpolymerized resin monomers. J Dent Res. 2001;80(7):1615-20. , 2323. Sheridan PJ, Koka S, Ewoldsen NO, Lefebvre CA, Lavin MT. Cytotoxicity of denture base resins. Int J Prosthodont. 1997;10(1):73-7. , 2424. Tsuchiya H, Hoshino Y, Tajima K, Takagi N. Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials. J Prosthet Dent. 1994;71(6):618-24. The polymer usually has the pigment that gives color to the resin.

Adding the monomer (methyl methacrylate, MMA) to the polymer causes a resin polymerization reaction that occurs without the formation of byproducts. Nevertheless, conversion of monomer into polymer is generally not complete,44. Gonçalves TS, Menezes LM, Silva LE. Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. Angle Orthod. 2008;78(4):722-7. for this reason, some amount of monomer, known as residual,22. Baker S, Brooks SC, Walker DM. The release of residual monomeric methyl methacrylate from acrylic appliances in the human mouth: an assay for monomer in saliva. J Dent Res. 1988;67(10):1295-9. remains. According to some studies, residual monomer remains in the manufactured orthodontic appliances, which indicates that varying amounts of residual monomer may be released into the oral cavity during the use of these appliances.44. Gonçalves TS, Menezes LM, Silva LE. Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. Angle Orthod. 2008;78(4):722-7. , 1010. Kedjarune U, Charoenworaluk N, Koontongkaew S. Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. Aust Dent J. 1999;44(1):25-30.

The residual monomer of methyl methacrylate not only changes the final physical properties of resins,33. Del Bel Cury AA, Rached RN, Ganzarolli SM. Microwave-cured acrylic resins and silicone-gypsum moulding technique. J Oral Rehabil. 2001;28(5):433-8. , 1212. Lee SY, Lai YL, Hsu TS. Influence of polymerization conditions on monomer elution and microhardness of autopolymerized polymelhyl methacrylate resin. Eur J Oral Sci. 2002;110(2):179-83. but also induces the onset of systemic and local tissue reactions when in contact with saliva and soft tissues,88. Hochman N, Zalkind M. Hypersensitivity to methyl methacrylate: mode of treatment. J Prosthet Dent. 1997;77(1):93-6. , 99. Jorge JH, Giampaolo ET, Machado AL, Vergani CE. Cytotoxicity of denture base acrylic resins: a literature review. J Prosthet Dent. 2003;90(2):190-3. , 1111. Lassila LVJ, Vallittu PK. Denture base polymer Alldent Sinomer(r): mechanical properties, water sorption and realease of residual compounds. J Oral Rehabil. 2001;28(7):607-13. , 1717. Nunes de Mello JA, Braun KO, Rached RN, Del Bel Cury AA. Reducing the negative effects of chemical polishing in acrylic resins by use of an additional cycle of polymerization. J Prosthet Dent. 2003;89(6):598-602. thus causing hypersensitivity, lip swelling, chronic urticaria and sialorrhea.55. Gonçalves TS, Morganti MA, Campos LC, Rizzatto SM, Menezes LM. Allergy to auto-polymerized acrylic resin in an orthodontic patient. Am J Orthod Dentofacial Orthop. 2006;129(3):431-5. , 66. Siqueira Gonçalves T, Minghelli Schmitt V, Thomas M, Lopes de Souza MA, Macedo de Menezes L. Cytotoxicity of two autopolymerized acrylic resins used in orthodontics. Angle Orthod. 2008;78(5):926-30. Furthermore, the pigment added to the powder may be another causative factor of hypersensitivity.

Although the in vitro cytotoxicity of MMA has already been demonstrated, no studies were conducted to assess the influence of pigments present in colored acrylics on cell viability. Thus, the aim of this study was to evaluate the in vitro cytotoxicity of acrylic resin at different periods and compare the cytotoxicity of acrylic resins of different colors.

MATERIAL AND METHODS

Preparation of specimens

For preparation of specimens, a metal matrix (10 mm X 5 mm X 2 mm) was molded with addition silicone (Express(r), 3M/ESPE, St. Paul, USA) and the mold filled with self-curing acrylic resin (Ortho Class(r), Classic, Campinas, São Paulo, Brazil). Powder-liquid ratio was obtained according to the manufacturer's instructions.

Each acrylic resin used for preparation of specimens was manipulated by means of the mass technique in a dappen dish with a lid where the monomer was inserted immediately before the polymer was poured until its saturation. Subsequently, the dish was covered with the lid, which allowed the resin to go through a sandy and fibrillar phase until it reached its plastic phase during which it was inserted into the mold. The acrylic resin was processed in a resin polymerizer M 1000(r) (EDG Equipment and Control Ltda.) at 20°C and pressure of 25 psi (1.75 kg/cm²) for a period of 15 minutes.

After polymerization, mechanical polishing was carried out in a vise using a bristle brush with a mixture pumice and water for 1 minute, followed by felt with white paste of Spain used for 1 minute.

Groups

Four self-curing acrylic resins of different colors were divided into four groups as follows (n = 3): Group 1 (clear), 2 (pink), 3 (blue) and 4 (green).

Control

To assess cellular response against extremes, other three groups (n = 3) were included: Group CC (cell control), cells which were not exposed to any material. This group was used to monitor normal cell growth. Group C+ (positive control) consisting of specimen made ​of amalgam. Silver amalgam was used because of its well known cytotoxic ability.1818. Pithon MM, Santos RL, Ruellas ACO, Sant'Anna EF, Romanos MTV, Silva-Mendes G. Avaliação in vitro da citotoxicidade de elásticos ortodônticos intermaxilares. Rev Odonto Ciênc. 2008;23(3):287-90. Specimens of 10 mm x 5 mm x 2 mm were manufactured in amalgamator (SDI(r), Bayswater, Australia) and polished with abrasive rubber tips. Group C- (negative control) consisting of glass specimen. Glass was the material of choice for not triggering cytotoxicity effect.1919. Pithon MM, Santos RL, Martins FO, Romanos MTV. Avaliação in vitro da citotoxicidade de parafusos expansores palatinos. Rev Odonto Ciênc. 2009;24(2):168-72.

Cell culture

Cell lineage used was L929 obtained from the American Type Culture Collection (ATCC, Rockville, MD) (mouse fibroblasts) grown in Eagle's minimum essential medium (MEM) (Cultilab, Campinas, São Paulo, Brazil), supplemented with 2 mM L glutamine (Sigma, St. Louis, Missouri, USA) 50 µg/mL gentamycin (Schering Plough, Kenilworth, New Jersey, USA), 2.5 µg/mL fungizone (Bristol Myers Squibb, New York, USA), 0.25 mL sodium bicarbonate solution (Merck, Darmstadt, Germany), 10 mM HEPES (Sigma, St. Louis, Missouri, USA) and 10 % fetal bovine serum (FBS) (Cultilab, Campinas, São Paulo, Brazil). It was kept at 37oC in an environment supplemented with 5 % CO2.

Cytotoxicity assay

Acrylic resin, silver amalgam and glass specimens were sterilized by exposure to UV light (Labconco, Kansas, Missouri, USA) for 1 hour.1919. Pithon MM, Santos RL, Martins FO, Romanos MTV. Avaliação in vitro da citotoxicidade de parafusos expansores palatinos. Rev Odonto Ciênc. 2009;24(2):168-72. Then, three samples of each material were placed in 24 well plates containing culture medium (MEM) (Cultilab, Campinas, São Paulo, Brazil). Supernatants were collected according to the time of evaluation, 24, 48, 72 and 168 hours (7 days), being the culture medium renewed every 24 hours.

Supernatants were placed, in triplicate, in 96 well plates containing confluent monolayer of L929 cells and incubated for 24 hours at 37oC in an environment containing 5 % CO2. After incubation, the effect on cell viability was determined by means of the dye-uptake technique, as described by Neyndorff et al,1616. Neyndorff HC, Bartel DL, Tufaro F, Levy JG. Development of a model to demonstrate photosensitizer-mediated viral inactivation in blood. Transfusion. 1990;30(6):485-90. but with minor modifications. The technique consists in adding 100 µL of 0.01 % neutral red (Sigma, St. Louis, Missouri, USA) into culture medium and incubation at 37°C for 3 hours for penetration of the dye in living cells.

After this period, the dye was discarded and the cells fixed for 5 minutes by adding 100 µL of formaldehyde solution (Reagen, Rio de Janeiro, Rio de Janeiro, Brazil) to 4 % in PBS (130 mM NaCl, 2 mM KCl; 6 mM Na2HPO4.2H2O, 1 mM K2HPO4, pH 7.2). Subsequently, the dye was extracted by adding 100 µL of a solution of 1 % acetic acid (Vetec, Rio de Janeiro, Rio de Janeiro, Brazil) and 50 % methanol (Reagen, Rio de Janeiro, Rio de Janeiro, Brazil). After 20 minutes, a spectrophotometer (BioTek, Winooski, Vermont, USA) at a wavelength of 492 ηm (λ = 492 ηm) was used to read the data.

Statistical analysis

Statistical analysis was performed with the SPSS 13.0 software (SPSS Inc., Chicago, Illinois, USA). Initially, data were submitted to Kolmogorov Smirnov and Levene's test to determine normality and homogeneity, respectively. The values ​​of the amount of viable cells were subjected to analysis of variance (ANOVA), with two factors (color and time) to determine whether there were statistical differences between groups, and subsequently to Tukey's test (Table 1). Significance level was set at 5 %.

Table 1
Mean and standard deviation of the amount of viable cells and statistical analysis of evaluated groups.

RESULTS

Results revealed increased cell viability from 24 to 48 h, a reduction in cell viability after 72 h and, an increase in cell viability after 168 h; however, with no statistically significant differences (P ≥ 0.05).

The color of resin proved not to influence material cytotoxicity, since there were no differences between groups 1, 2, 3 and 4 at all times (P ≥ 0.05).

At all times, the values ​​of cell viability were statistically similar between clear acrylic resin (group 1) and blue acrylic resin (group 3), as well as between groups C- and CC (P ≥ 0.05), thus proving the absence of cytotoxic effect of acrylic resin to fibroblasts. However, experimental group 2 (pink acrylic resin) and 4 (green acrylic resin) showed significant differences in comparison to group CC (P < 0.05) after 24 h, thus indicating a difference in normal cell growth. Group C+ showed statistical difference in comparison to all other groups at all time periods studied, thus showing a decrease in the number of viable cells.

DISCUSSION

Acrylic resins are widely used in Dentistry; however, some studies have demonstrated that this material can cause allergic reactions.1313. Lunder T, Rogl-Butina M. Chronic urticaria from an acrylic dental prosthesis. Contact Dermatitis. 2000;43(4):232-3. , 1414. McCabe JF, Basker RM. Tissue sensitivity to acrylic resin. A method of measuring the residual monomer content and its clinical application. Br Dent J. 1976;140(10):347-50. , 1515. Nealey ET, Del Rio CE. Stomatitis venenata: reaction of a patient to acrylic resin. J Prosthet Dent. 1969;21(5):480-4. Nevertheless, most researches assessed material used for prosthetic purposes, most of which are heat-curing

Self-curing ​​acrylic resins are the most frequently used in Orthodontics. According to Hensten Pettersen and Wictorin,77. Hensten-Pettersen A, Wictorin L. The cytotoxic effect of denture base polymers. Acta Odontol Scand. 1981;39(2):101-6. polymerization influences cytotoxicity. Their studies revealed lower cell growth in self-curing ​​resins in comparison to heat-curing ones, and for both, cell growth was lower than in the control group.

Baker et al22. Baker S, Brooks SC, Walker DM. The release of residual monomeric methyl methacrylate from acrylic appliances in the human mouth: an assay for monomer in saliva. J Dent Res. 1988;67(10):1295-9. found that residual monomer concentration was four times higher in saliva adjacent to the palatal surface of appliances manufactured ​​with acrylic resin in comparison to total saliva, thus indicating the importance of assessing cytotoxicity of this material, as well as the effects produced by the pigment and by the time of exposure on material cytotoxic potential.

Acrylic resin color proved not to affect cell viability, thus suggesting that the pigment does not influence cytotoxicity levels. However, when specimens were made ​​of pink and green acrylic resin, normal cell growth was modified, as shown by experimental groups 2 and 4 which differed from CC. Thus, toxic reaction seems not to be associated with neither pigment nor the other substances that constitute the polymer, but with increase in the level of residual monomer present in the material.66. Siqueira Gonçalves T, Minghelli Schmitt V, Thomas M, Lopes de Souza MA, Macedo de Menezes L. Cytotoxicity of two autopolymerized acrylic resins used in orthodontics. Angle Orthod. 2008;78(5):926-30.

In this study, groups 1, 2, 3 and 4 showed no statistically significant differences over time (P ≤ 0.05), thus indicating that cytotoxicity was not affected within the times tested. This finding is in disagreement with Gonçalves et al66. Siqueira Gonçalves T, Minghelli Schmitt V, Thomas M, Lopes de Souza MA, Macedo de Menezes L. Cytotoxicity of two autopolymerized acrylic resins used in orthodontics. Angle Orthod. 2008;78(5):926-30. who assessed cytotoxicity of acrylic resins for orthodontic purposes within 24 and 48 hours. Their results showed that there was less cell viability after 24 hours. This difference can be explained by the cell type used, given that Gonçalves et al66. Siqueira Gonçalves T, Minghelli Schmitt V, Thomas M, Lopes de Souza MA, Macedo de Menezes L. Cytotoxicity of two autopolymerized acrylic resins used in orthodontics. Angle Orthod. 2008;78(5):926-30. used epithelial cells and not fibroblasts. Polishing may also be considered as, according to Rocha Filho et al2020. Rocha Filho R, Paula LV, Costa VC, Seraidarian PI. Avaliação de monômero residual em resinas acrílicas de uso ortodôntico e protético: análise por espectroscopia. Rev Dental Press Ortod Ortop Facial. 2007;12(2):96-104. and Gonçalves et al,44. Gonçalves TS, Menezes LM, Silva LE. Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. Angle Orthod. 2008;78(4):722-7. it alters the level of residual monomer present in the acrylic resins. Release of residual monomer is responsible for the reduction in cell viability, and this release is more intense within the first 24 h.44. Gonçalves TS, Menezes LM, Silva LE. Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. Angle Orthod. 2008;78(4):722-7. However, mechanical polishing decreases the levels of residual monomer66. Siqueira Gonçalves T, Minghelli Schmitt V, Thomas M, Lopes de Souza MA, Macedo de Menezes L. Cytotoxicity of two autopolymerized acrylic resins used in orthodontics. Angle Orthod. 2008;78(5):926-30.. For this reason, it is suggested that the polishing procedure performed in this study was key not to trigger toxic reaction.

Although there was no significant difference between the times of assessment, in all experimental groups, from 48 to 72 hours there was a decrease in the number of viable cells. The fact that release of residual monomer is considered crucial in determining cell viability corroborates the results by Rocha Filho et al.2020. Rocha Filho R, Paula LV, Costa VC, Seraidarian PI. Avaliação de monômero residual em resinas acrílicas de uso ortodôntico e protético: análise por espectroscopia. Rev Dental Press Ortod Ortop Facial. 2007;12(2):96-104. In the graphs of this study, the authors demonstrate increased concentration of residual monomer from 2 to 5 days.

It is recommended that acrylic resin used to manufacture orthodontic appliances be properly proportioned and manipulated, following the manufacturer's recommendations to ensure safety for patients' health. Some measures may be taken to reduce the amount of residual monomer, such as: polymerization in water or under pressure, the use of correct monomer : polymer proportion, and storage in water for 72 hours after polymerization.22. Baker S, Brooks SC, Walker DM. The release of residual monomeric methyl methacrylate from acrylic appliances in the human mouth: an assay for monomer in saliva. J Dent Res. 1988;67(10):1295-9. , 1717. Nunes de Mello JA, Braun KO, Rached RN, Del Bel Cury AA. Reducing the negative effects of chemical polishing in acrylic resins by use of an additional cycle of polymerization. J Prosthet Dent. 2003;89(6):598-602. , 2121. Rose EC, Bumann J, Jonas IE, Kappert HF. Contribution to the biological assessment of orthodontic acrylic materials. Measurement of their residual monomer output and cytotoxicity. J Orofac Orthop. 2000;61(4):246-57. Moreover, the different colors of resin tested can be used without causing any damage to the biocompatibility of the material.

CONCLUSION

According to the methodology used and the conditions established in this research, it can be concluded that:

  • 1) Acrylic resin manufactured by means of the mass technique, polymerized under pressure and mechanically polished does not alter cell viability.

  • 2) Color of acrylic resin has no effect on cell viability.

  • 3) Cell viability is maintained when exposed to self-curing acrylic resin.

REFERENCES

  • 1
    Aydin O, Attila G, Dogan A, Aydin MV, Canacankatan N, Kanik A. The effects of methyl methacrylate on nasal cavity, lung, and antioxidant system (an experimental inhalation study). Toxicol Pathol. 2002;30(3):350-6.
  • 2
    Baker S, Brooks SC, Walker DM. The release of residual monomeric methyl methacrylate from acrylic appliances in the human mouth: an assay for monomer in saliva. J Dent Res. 1988;67(10):1295-9.
  • 3
    Del Bel Cury AA, Rached RN, Ganzarolli SM. Microwave-cured acrylic resins and silicone-gypsum moulding technique. J Oral Rehabil. 2001;28(5):433-8.
  • 4
    Gonçalves TS, Menezes LM, Silva LE. Residual monomer of autopolymerized acrylic resin according to different manipulation and polishing methods. Angle Orthod. 2008;78(4):722-7.
  • 5
    Gonçalves TS, Morganti MA, Campos LC, Rizzatto SM, Menezes LM. Allergy to auto-polymerized acrylic resin in an orthodontic patient. Am J Orthod Dentofacial Orthop. 2006;129(3):431-5.
  • 6
    Siqueira Gonçalves T, Minghelli Schmitt V, Thomas M, Lopes de Souza MA, Macedo de Menezes L. Cytotoxicity of two autopolymerized acrylic resins used in orthodontics. Angle Orthod. 2008;78(5):926-30.
  • 7
    Hensten-Pettersen A, Wictorin L. The cytotoxic effect of denture base polymers. Acta Odontol Scand. 1981;39(2):101-6.
  • 8
    Hochman N, Zalkind M. Hypersensitivity to methyl methacrylate: mode of treatment. J Prosthet Dent. 1997;77(1):93-6.
  • 9
    Jorge JH, Giampaolo ET, Machado AL, Vergani CE. Cytotoxicity of denture base acrylic resins: a literature review. J Prosthet Dent. 2003;90(2):190-3.
  • 10
    Kedjarune U, Charoenworaluk N, Koontongkaew S. Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. Aust Dent J. 1999;44(1):25-30.
  • 11
    Lassila LVJ, Vallittu PK. Denture base polymer Alldent Sinomer(r): mechanical properties, water sorption and realease of residual compounds. J Oral Rehabil. 2001;28(7):607-13.
  • 12
    Lee SY, Lai YL, Hsu TS. Influence of polymerization conditions on monomer elution and microhardness of autopolymerized polymelhyl methacrylate resin. Eur J Oral Sci. 2002;110(2):179-83.
  • 13
    Lunder T, Rogl-Butina M. Chronic urticaria from an acrylic dental prosthesis. Contact Dermatitis. 2000;43(4):232-3.
  • 14
    McCabe JF, Basker RM. Tissue sensitivity to acrylic resin. A method of measuring the residual monomer content and its clinical application. Br Dent J. 1976;140(10):347-50.
  • 15
    Nealey ET, Del Rio CE. Stomatitis venenata: reaction of a patient to acrylic resin. J Prosthet Dent. 1969;21(5):480-4.
  • 16
    Neyndorff HC, Bartel DL, Tufaro F, Levy JG. Development of a model to demonstrate photosensitizer-mediated viral inactivation in blood. Transfusion. 1990;30(6):485-90.
  • 17
    Nunes de Mello JA, Braun KO, Rached RN, Del Bel Cury AA. Reducing the negative effects of chemical polishing in acrylic resins by use of an additional cycle of polymerization. J Prosthet Dent. 2003;89(6):598-602.
  • 18
    Pithon MM, Santos RL, Ruellas ACO, Sant'Anna EF, Romanos MTV, Silva-Mendes G. Avaliação in vitro da citotoxicidade de elásticos ortodônticos intermaxilares. Rev Odonto Ciênc. 2008;23(3):287-90.
  • 19
    Pithon MM, Santos RL, Martins FO, Romanos MTV. Avaliação in vitro da citotoxicidade de parafusos expansores palatinos. Rev Odonto Ciênc. 2009;24(2):168-72.
  • 20
    Rocha Filho R, Paula LV, Costa VC, Seraidarian PI. Avaliação de monômero residual em resinas acrílicas de uso ortodôntico e protético: análise por espectroscopia. Rev Dental Press Ortod Ortop Facial. 2007;12(2):96-104.
  • 21
    Rose EC, Bumann J, Jonas IE, Kappert HF. Contribution to the biological assessment of orthodontic acrylic materials. Measurement of their residual monomer output and cytotoxicity. J Orofac Orthop. 2000;61(4):246-57.
  • 22
    Schweikl H, Schmalz G, Spruss T. The induction of micronuclei in vitro by unpolymerized resin monomers. J Dent Res. 2001;80(7):1615-20.
  • 23
    Sheridan PJ, Koka S, Ewoldsen NO, Lefebvre CA, Lavin MT. Cytotoxicity of denture base resins. Int J Prosthodont. 1997;10(1):73-7.
  • 24
    Tsuchiya H, Hoshino Y, Tajima K, Takagi N. Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials. J Prosthet Dent. 1994;71(6):618-24.
  • » The authors report no commercial, proprietary or financial interest in the products or companies described in this article.

Publication Dates

  • Publication in this collection
    Jul-Aug 2014

History

  • Received
    18 May 2009
  • Accepted
    12 Apr 2010
Dental Press International Av. Luís Teixeira Mendes, 2712 , 87015-001 - Maringá - PR, Tel: (55 44) 3033-9818 - Maringá - PR - Brazil
E-mail: artigos@dentalpress.com.br