Acessibilidade / Reportar erro

Performance of the Titanium-Nitride-Oxide Coated Stent in Patients with Multivessel Coronary Artery Disease

Abstracts

Background:

To date, there are no studies evaluating the use of the titanium-nitride-oxide coated stent in patients with multivessel coronary artery disease. We have compared the performance of the Titan-2® stent to that of the second generation drug-eluting stents in this scenario.

Methods:

From 2011 to 2012, 284 patients were treated with the Titan-2® stent, of which 100 (35.2%) had multivessel coronary artery disease. This group was compared to 100 patients, of a group of 304 (38.9%) patients with multivessel coronary artery disease treated with second generation drug-eluting stents with durable or biodegradable polymers. The primary endpoint was the occurrence of major adverse cardiovascular events at 1 year.

Results:

Clinical, angiographic and procedure-related characteristics of the patients did not show differences between groups. Most patients in the Titan-2® group were male (70%), mean age was 68.4 ± 12.9 years and 25% were diabetic. Stable symptomatic patients were prevalent (68%), 51% had three-vessel disease and ventricular function was preserved (55.6 ± 12.7%). The incidence of major adverse cardiovascular events at 1 year in the Titan-2® group was 21% (vs. 17%; p = 0.59), death was observed in 3% (vs. 2%; p > 0.99) of the patients, acute myocardial infarction in 5% (vs. 4%; p > 0.99) and a new revascularization procedure in 13% (vs. 11%; p = 0.83). Definitive stent thrombosis was not observed in either group.

Conclusions:

The Titan-2® stent showed similar results to those of the second-generation drug-eluting stents, which makes it attractive for use in the complex scenario of patients with multivessel coronary artery disease.

Percutaneous coronary intervention; Stents; Coated materials, biocompatible; Titanium


Introdução:

Até o momento, nenhum estudo avaliou o stent recoberto por titânio-óxido nítrico em pacientes com doença arterial coronariana multiarterial. Comparamos o desempenho do stent Titan-2® ao stents farmacológicos de segunda geração nesse cenário.

Métodos:

No período de 2011 a 2012, 284 pacientes foram tratados com o stent Titan-2®, dos quais 100 (35,2%) eram portadores de doença arterial coronariana multiarterial. Esse grupo foi comparado a 100 pacientes, de um grupo de 304 (38,9%), com doença arterial coronariana multiarterial, tratados com o stent farmacológico de segunda geração com polímeros duráveis ou biodegradáveis. O desfecho primário foi a ocorrência de eventos cardíacos adversos maiores em 1 ano.

Resultados:

Características clínicas, angiográficas e do procedimento não apresentaram diferenças entre os grupos. A maioria dos pacientes do grupo Titan-2® era do sexo masculino (70%), com idade de 68,4 ± 12,9 anos e 25% eram diabéticos. Predominaram os quadros clínicos estáveis (68%), 51% tinham acometimento triarterial e a função ventricular estava preservada. A incidência de eventos cardiovasculares adversos maiores em 1 ano no grupo Titan-2® foi de 21% (vs. 17%; p = 0,59), óbito ocorreu em 3% (vs. 2%; p > 0,99) dos pacientes, infarto do miocárdio em 5% (vs. 4%; p > 0,99) e nova revascularização miocárdica em 13% (vs. 11%; p = 0,83). Não foram constatadas tromboses de stent definitivas em nenhum grupo.

Conclusões:

O uso do Titan-2® apresentou resultados similares aos do stent farmacológico de segunda geração, o que o torna atrativo para ser utilizado no complexo cenário de pacientes portadores de doença arterial coronariana multiarterial.

Intervenção coronária percutânea; Stents; Materiais revestidos biocompatíveis; Titânio


Coronary stent implantation has become the standard percutaneous coronary intervention, with a safer approach and better results than those obtained with balloon angioplasty.1Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, et al.; Stent Restenosis Study Investigators. A randomized comparison of coronary stent placement and balloon angioplasty in treatment of coronary artery disease. N Engl J Med. 1994;331(8):496-501.,2Serruys P, de Jaegere P, Kiemenneij F, Macaya C, Rutsch W, Heyndrickx G, et al. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331(8):489-95. However, coronary restenosis, although reduced, still remains as a limitation of the procedure, resulting in the need for new procedures and increased costs.3Peterson ED, Cowper PA, DeLong ER, Zidar JP, Stack RS, Mark DB. Acute and long-term cost implications of coronary stenting. J Am Coll Cardiol. 1999;33(6):1610-8. Drug-eluting stents (DES) have significantly reduced late luminal loss and angiographic restenosis, as well as the need for repeat revascularization, when compared to bare metal stents (BMS).4Daemen J, Garcia-Garcia HM, Kukreja N, Imani F, de Jaegere PP, Sianos G, et al. The long-term value of sirolimus- and paclitaxel- eluting stents over bare metal stents in patients with diabetes mellitus. Eur Heart J. 2007;28(1):26-32. This reduction has been significant in several clinical and anatomical scenarios,5Stefanini GG, Holmes DR Jr. Drug-eluting coronary-artery stents. N Engl J Med. 2013;368(3):254-65.

Centemero MP, Cherobin JC, De Conti KVF, Ohe LN, Mallmann N, Farkouh ME, et al. Doença arterial coronária e diabetes: do tratamento farmacológico aos procedimentos de revascularização. Rev Bras Cardiol Invasiva. 2009;17(3):398-413.

Pinheiro LFM, Pimentel Filho WA, Custódio WB, Fioroto WB, Soares Neto MM. Treatment of acute myocardial infarction with placement of drug eluting stents. Int J Atheroscler. 2007; 2:265-71.

Bangalore S, Toklu B, Amoroso N, Fusaro M, Kumar S, Hannan EL, et al. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis. BMJ. 2013;347:f6625.
-9Buchanan GL, Chieffo A, Bernelli C, Montonfano M, Carlino M, Latib A, et al. Two-year outcomes following unprotected left main stenting with first vs. new-generation drug-eluting stents: the FINE registry. EuroIntervention. 2013;9(7):809-16. especially with second-generation stents.8Bangalore S, Toklu B, Amoroso N, Fusaro M, Kumar S, Hannan EL, et al. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis. BMJ. 2013;347:f6625.

The Titan-2® bioactive stent (Hexacath - Paris, France) is approved for clinical use in Europe, Asia, and North, Central, and South America, including Brazil, with more than 5,000 units already used worldwide.1010 Sant'Anna FM, Batista LA, Brito MB, Menezes S, Ventura FM, Buczynski L, et al. Estudo randomizado e comparativo da intervenção coronária percutânea com stents recobertos por titânio-óxido nítrico ou de Aço Inoxidável em pacientes com doença arterial coronária: estudo RIO. Rev Bras Cardiol Invasiva. 2009;17(1):69-75.,1111 Angioi M, Barragan P, Cattan S, Collet F, Dupouy P, Durand P, et al. French Ministry of Health prospective multicentre study using bio-active stents coated with titanium nitride oxide: the EVIDENCE registry. Arch Cardiovas Dis. 2012;105(2):60-7. This stent consists of stainless steel coated with titanium-nitride-oxide, which has shown in vitro to reduce platelet aggregation and fibrinogen binding when compared to conventional bare metal stents. Preliminary data have shown similar safety and efficacy profiles of first- and second-generation DES in several clinical scenarios.1111 Angioi M, Barragan P, Cattan S, Collet F, Dupouy P, Durand P, et al. French Ministry of Health prospective multicentre study using bio-active stents coated with titanium nitride oxide: the EVIDENCE registry. Arch Cardiovas Dis. 2012;105(2):60-7.

12 Karjalainen P, Ylitalo A, Juhani Airaksinen KE. Titanium and nitride oxide coated stents and paclitaxel eluting stents for coronary revascularization in an unselected population. J Invasive Cardiol. 2006;18(10):462-8.

13 Karjalainen P, Ylitalo A, Juhani Airaksinen KE. Real world experience with TITAN® stent: a 9-month follow-up report from the Titan PORI Registry. EuroIntervention. 2006;2(2):187-91.

14 Giraud-Sauveur Y. TITAN 2 Bio-active stent (BAS) with titanium-NO. EuroIntervention. 2008;3(4):526-8.

15 Karjalainen P. Titan 2 Stent vs. Xience V Stent: 18-month follow-up of the BASE-ACS Randomized Trial [Internet]. [cited 2014 Apr 12]. Available from: http://www.pcronline.com/ Lectures/2012
http://www.pcronline.com/ ...

16 Romppanen H, Nammas W, Kervinen K, Mikkelsson J, Pietilä M, Lalmand J, et al. Outcome of ST-elevation myocardial infarction versus non-ST-elevation acute coronary syndrome treated with titanium-nitride-oxide-coated versus everolimuseluting stents: insights from the BASE-ACS trial. Minerva Cardioangiol. 2013;61(2):201-9.

17 Limacher A, Räber L, Laube E, Lauterburg A, Lötscher S, Hess N, et al. Clinical long-term outcome after implantation of titanium nitride-oxide coated stents compared with paclitaxel- or sirolimus-eluting stents: propensity-score matched analysis. EuroIntervention. 2012;7(9):1043-50.
-1818 Karjalainen PP, Niemelä M, Airaksinen JK, Rivero-Crespo F, Romppanen H, Sia J, et al. A prospective randomised comparison of titanium-nitride-oxide-coated bioactive stents with everolimus-eluting stents in acute coronary syndrome: the BASE-ACS trial. EuroIntervention. 2012;8(3):306-15. However, few studies have addressed the performance of the Titan-2® in the treatment of patients with multivessel coronary artery disease (CAD).

This study aimed to evaluate the performance of the Titan-2® stent in patients with multivessel CAD and compare it to that of second-generation DES.

METHODS

Patients

From January 2011 to December 2012, 284 patients were treated at Hospital Beneficência Portuguesa de São Paulo with the Titan-2® stent, of whom 100 (35.2%) had multivessel CAD and were selected for this analysis. This study excluded cases whose initial clinical presentation was myocardial infarction with ST-segment elevation, and those who had lesions > 50% in the left main coronary artery or when the percutaneous coronary intervention was performed with saphenous vein grafts. This group was compared to 100 patients from a group of 304 (38.9%) patients with multivessel CAD treated with secondgeneration DES with durable polymers - Endeavor® (Medtronic, Minneapolis, United States) or Xience V® (Abbott Vascular, Santa Clara, United States), and biodegradable polymers - BioMatrix® (Biosensors International, Singapore), in the same period, at the present institution.

The study was conducted in agreement with the Declaration of Helsinki, and all patients signed an informed consent.

The Stents

The Titan-2® balloon-expandable stent combines a stainless steel platform (316 L) of thin struts (0.0040 inch) with open cells and helical connections. It is not coated with polymers or antiproliferative drugs, but rather with a titanium matrix system bound to nitride oxide, applied by vapor deposition on the stent surface.

Stents that were used as controls included the Endeavor®, which releases zotarolimus from a biocompatible phosphorylcholine polymer applied to a cobalt-chromium platform of thin struts; the XienceV® , which releases everolimus from a biocompatible fluorinated acrylic polymer applied to a platform of cobalt-chromium with thin struts; and the BioMatrix®, which releases biolimus A9 from a biodegradable polylactic acid polymer applied to a stainless steel platform with thin struts.

Procedure

Percutaneous coronary interventions were performed according to current guidelines,1919 Gubolino LA, Mangione JA, Silva SS, Queiroga MAC, Marin-Neto JA. Sociedade Brasileira de Cardiologia. Diretrizes da Sociedade Brasileira de Cardiologia sobre Qualidade Profissional e Institucional, Centro de Treinamento e Certificação Profissional em Hemodinâmica e Cardiologia Intervencionista - III Edição -2013. Arq Bras Cardiol. 2013;101Supl. 4:1-58.,2020 Harold JG, Bass TA, Bashore TM, Brindis RG, Brush JE Jr, Burke JA, et al. ACCF/AHA/SCAI 2013 update of the clinical competence statement on coronary artery interventional procedures: a report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training (Writing Committee to Revise the 2007 Clinical Competence Statement on Cardiac Interventional Procedures). J Am Coll Cardiol. 2013;62(4):357-96. and the final strategy for the procedure was left to the discretion of the surgeon.

During the procedure, unfractionated heparin was administered at a dose of 70-100 IU/kg, and the use of glycoprotein IIb/IIIa inhibitors was at the discretion of the surgeon. Pre-dilation was not compulsory, and post-dilation of stents was recommended in case of residual stenosis > 20% by visual estimation. The administration of dual antiplatelet therapy (acetylsalicylic acid [loading dose 200 mg/100 mg maintenance] and clopidogrel [loading dose 300-600 mg/75 mg maintenance]) should be started at least 24 hours before the procedure. In patients with acute coronary syndromes, a loading dose of 600 mg of clopidogrel, 60 mg of prasugrel, or 180 mg of ticagrelor was recommended. After PCI, therapy with aspirin was maintained indefinitely; clopidogrel, prasugrel (10 mg/day), or ticagrelor (90 mg/day) were maintained for a period of 1 to 3 months for the Titan-2® group, and for at least one year for the DES group.

Outcomes and clinical follow-up

The primary study endpoint was the occurrence of major adverse cardiac events (MACE) during a 12 month follow-up. MACE was defined as death, non-fatal myocardial infarction, and need for repeat revascularization. All deaths were considered cardiac unless a non-cardiac cause could be clearly established by clinical and/or pathological study. The diagnosis of myocardial infarction was based on the development of new pathological Q waves in more than two contiguous ECG leads and/or elevation of creatine kinase MB isoenzyme (CK-MB) greater than three times the upper limit of the normal level after the procedure (during the index hospitalization), or twice the upper limit of the normal level after discharge. All new revascularizations, whether percutaneous or surgical, were considered. Definite stent thrombosis was diagnosed according to the criteria of the Academic Research Consortium.2121 Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al.; Academic Research Consortiun. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115(17):2344-51

Clinical follow-up was performed at 12 months after the procedure, consisting of telephone contact performed according to pre-established institutional protocol.

Statistical Analysis

Categorical variables were described as percentages and compared by the chi-squared or Fisher's exact test, when appropriate. Continuous variables were described as means and standard deviations and compared using Student's t-test. p-values < 0.05 were considered statistically significant.

RESULTS

The clinical, anatomical, and procedural characteristics of the patients are summarized in Table 1, demonstrating no statistically significant differences between the groups. Most patients from the Titan-2® group were males (70%), with a mean age of 68.4 ± 12.9 years, and 25% were diabetics (4.0% used insulin). Stable clinical pictures predominated in the clinical presentation (68%), 51% had three-vessel CAD, and ventricular function was preserved (55.6 ± 12.7%). In patients with three-vessel CAD treated with the titanium-nitride-oxide stent, 135 lesions were treated. Of these, 78% were treated with three or more stents; the remaining cases (22%) were treated with two stents. In patients with two-vessel CAD, 110 lesions were treated; 80% of cases were treated with two or more stents and only one stent was used in the others. In patients with three-vessel CAD treated with drug-eluting stents; 141 lesions were treated, with three or more stents in 77% of cases, and with two stents used in the others. In patients with two-vessel CAD, 115 lesions were treated with two or more stents in 78% of cases, and only one stent was used in the others.

TABLE 1
Clinical, angiographic, and procedural characteristics

The incidence of MACE at 1 year in the Titan-2® group was 21% (vs. 17%; p = 0.59) and death occurred in 3% (vs. 2%; p > 0.99) of patients, myocardial infarction in 5% (vs. 4%; p > 0.99), and new revascularization procedure in 13% (vs. 11%, p = 0.83), predominantly at the expense of a new PCI in more than three-quarters of the cases (Table 2). No definite stent thrombosis was observed in either group.

TABLE 2
Frequency of major adverse cardiovascular events during a one-year period

DISCUSSION

In this study, it was demonstrated that clinical outcomes at one year of Titan-2® stent implantation in a clinical and anatomical scenario of greater complexity (patients with multivessel CAD, of whom approximately 25% were diabetics with predominantly type B2/C lesions according to the classification of the American Heart Association/American College of Cardiology) were similar to those of the group of patients who received second-generation DES implantation with durable or biodegradable polymers.

Modifications of the stent surface and material properties may have important implications for neointimal hyperplasia after stent implantation. Metallic implants can induce the exchange of electrons and protons, as well as the formation of ion-organic molecular bonds in living tissue. The resulting protein activation, cell toxicity, and stimulation of platelets, monocytes/macrophages, and fibroblasts may contribute to restenosis.2222 Mosseri M, Miller H, Tamari I, Plich M, Hasin Y, Brizines M, et al. The Titanium-NO Stent: results of a multicenter registry. EuroIntervention. 2006;2(2):192-6.

Both stainless steel and cobalt-chromium have significant amounts of nickel, chromium, and molybdenum, which can be released from the stent and induce the aforementioned tissue reactions. The inflammatory and allergic reactions that induce the formation of new tissue around metal alloys containing nickel in patients with orthopedic and dental implants are well known.2323 Steinemann SG. Metal implants and surface reactions. Injury. 1996;27 Suppl 3:SC16-22. It is reasonable to assume that stents that contain nickel and other elements can increase neointimal hyperplasia.

Several types of stent coating have been used to create a biologically inert barrier between the metallic prosthesis surface and the circulating blood, but none has reduced rates of restenosis, and others, such as gold, increased such rates. An evaluation of five different biodegradable polymers and three no biodegradable polymers showed inflammatory reactions with subsequent coronary neointimal thickening, which was not expected based on in vitro tests.2424 van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes DR, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation. 1996; 94(7):1690-7. It is speculated that this inflammatory process might contribute to coronary restenosis and, eventually, to late thrombosis. Thus, it is necessary to improve the characteristics of the metallic stents, even as a platform for the release of antiproliferative drugs.

Titanium is the material of choice for biomedical implants, especially dental and orthopedic implants, because of its superior biocompatibility and resistance to corrosion. However, the processing of this metal is difficult, and its production costs are prohibitive. In contrast, titanium alloys, such as titanium-nitride oxide, can be more easily used and applied to stainless steel surfaces through physical vapor deposition at a reasonable cost. Titanium-nitride-oxide surfaces have been experimentally demonstrated to reduce the binding of platelets and fibrinogen in comparison to stainless steel.2525 Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, et al. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005;111(20):2617-22. Moreover, neointimal hyperplasia was reduced by 50% in a porcine model, when compared to a conventional stainless steel stent.2626 Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, et al. Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001; 104(8):928-33.

When compared to conventional stents, stents coated with titanium-nitride-oxide showed to be superior in reducing restenosis and major adverse cardiovascular events.1010 Sant'Anna FM, Batista LA, Brito MB, Menezes S, Ventura FM, Buczynski L, et al. Estudo randomizado e comparativo da intervenção coronária percutânea com stents recobertos por titânio-óxido nítrico ou de Aço Inoxidável em pacientes com doença arterial coronária: estudo RIO. Rev Bras Cardiol Invasiva. 2009;17(1):69-75.,2525 Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, et al. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005;111(20):2617-22.,2727 Moschovitis A, Simon R, Seidenstücker A, Klauss V, Baylacher M, Lüscher TF, et al. Randomized comparison of titanium-nitride-oxide coated stents with bare metal stents: five year follow-up of the TiNOX trial. EuroIntervention. 2010;6(1):63-8. In the case of first- and second-generation DES, several studies,1111 Angioi M, Barragan P, Cattan S, Collet F, Dupouy P, Durand P, et al. French Ministry of Health prospective multicentre study using bio-active stents coated with titanium nitride oxide: the EVIDENCE registry. Arch Cardiovas Dis. 2012;105(2):60-7.

12 Karjalainen P, Ylitalo A, Juhani Airaksinen KE. Titanium and nitride oxide coated stents and paclitaxel eluting stents for coronary revascularization in an unselected population. J Invasive Cardiol. 2006;18(10):462-8.

13 Karjalainen P, Ylitalo A, Juhani Airaksinen KE. Real world experience with TITAN® stent: a 9-month follow-up report from the Titan PORI Registry. EuroIntervention. 2006;2(2):187-91.

14 Giraud-Sauveur Y. TITAN 2 Bio-active stent (BAS) with titanium-NO. EuroIntervention. 2008;3(4):526-8.

15 Karjalainen P. Titan 2 Stent vs. Xience V Stent: 18-month follow-up of the BASE-ACS Randomized Trial [Internet]. [cited 2014 Apr 12]. Available from: http://www.pcronline.com/ Lectures/2012
http://www.pcronline.com/ ...

16 Romppanen H, Nammas W, Kervinen K, Mikkelsson J, Pietilä M, Lalmand J, et al. Outcome of ST-elevation myocardial infarction versus non-ST-elevation acute coronary syndrome treated with titanium-nitride-oxide-coated versus everolimuseluting stents: insights from the BASE-ACS trial. Minerva Cardioangiol. 2013;61(2):201-9.

17 Limacher A, Räber L, Laube E, Lauterburg A, Lötscher S, Hess N, et al. Clinical long-term outcome after implantation of titanium nitride-oxide coated stents compared with paclitaxel- or sirolimus-eluting stents: propensity-score matched analysis. EuroIntervention. 2012;7(9):1043-50.
-1818 Karjalainen PP, Niemelä M, Airaksinen JK, Rivero-Crespo F, Romppanen H, Sia J, et al. A prospective randomised comparison of titanium-nitride-oxide-coated bioactive stents with everolimus-eluting stents in acute coronary syndrome: the BASE-ACS trial. EuroIntervention. 2012;8(3):306-15. but not all,2727 Moschovitis A, Simon R, Seidenstücker A, Klauss V, Baylacher M, Lüscher TF, et al. Randomized comparison of titanium-nitride-oxide coated stents with bare metal stents: five year follow-up of the TiNOX trial. EuroIntervention. 2010;6(1):63-8.,2828 López-Mínguez JR, Nogales-Asensio JM, Doncel-Vecino LJ, Merchán-Herrera A, Pomar-Domingo F, Martínez-Romero P, et al. A Randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results. Rev Esp Cardiol. 2014 Apr 3. [Epub ahead of print]. demonstrated that the Titan-2® showed similar benefits to those of DES and did not require prolonged dual antiplatelet therapy (> 1 month for stable patients and > 3 months for those with acute coronary syndromes), as late thrombosis was not observed.1717 Limacher A, Räber L, Laube E, Lauterburg A, Lötscher S, Hess N, et al. Clinical long-term outcome after implantation of titanium nitride-oxide coated stents compared with paclitaxel- or sirolimus-eluting stents: propensity-score matched analysis. EuroIntervention. 2012;7(9):1043-50.

Study limitations

The results of this study should be interpreted in the context of the following limitations: it was a nonrandomized study and, therefore, subject to selection biases; the patient population was too small to detect differences in clinical events of minor importance; clinical information was obtained predominantly by the present team or by telephone contact with the assistant physician, and there was no long-term follow-up (> 1 year).

CONCLUSIONS

This study suggests that the Titan-2® stent has a similar safety and efficacy profile to that of secondgeneration drug-eluting stents, which makes it attractive for use in the treatment of the complex scenario of patients with multivessel coronary artery disease, particularly when long-term dual antiplatelet therapy is not intended.

REFERÊNCIAS

  • 1
    Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, et al.; Stent Restenosis Study Investigators. A randomized comparison of coronary stent placement and balloon angioplasty in treatment of coronary artery disease. N Engl J Med. 1994;331(8):496-501.
  • 2
    Serruys P, de Jaegere P, Kiemenneij F, Macaya C, Rutsch W, Heyndrickx G, et al. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331(8):489-95.
  • 3
    Peterson ED, Cowper PA, DeLong ER, Zidar JP, Stack RS, Mark DB. Acute and long-term cost implications of coronary stenting. J Am Coll Cardiol. 1999;33(6):1610-8.
  • 4
    Daemen J, Garcia-Garcia HM, Kukreja N, Imani F, de Jaegere PP, Sianos G, et al. The long-term value of sirolimus- and paclitaxel- eluting stents over bare metal stents in patients with diabetes mellitus. Eur Heart J. 2007;28(1):26-32.
  • 5
    Stefanini GG, Holmes DR Jr. Drug-eluting coronary-artery stents. N Engl J Med. 2013;368(3):254-65.
  • 6
    Centemero MP, Cherobin JC, De Conti KVF, Ohe LN, Mallmann N, Farkouh ME, et al. Doença arterial coronária e diabetes: do tratamento farmacológico aos procedimentos de revascularização. Rev Bras Cardiol Invasiva. 2009;17(3):398-413.
  • 7
    Pinheiro LFM, Pimentel Filho WA, Custódio WB, Fioroto WB, Soares Neto MM. Treatment of acute myocardial infarction with placement of drug eluting stents. Int J Atheroscler. 2007; 2:265-71.
  • 8
    Bangalore S, Toklu B, Amoroso N, Fusaro M, Kumar S, Hannan EL, et al. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis. BMJ. 2013;347:f6625.
  • 9
    Buchanan GL, Chieffo A, Bernelli C, Montonfano M, Carlino M, Latib A, et al. Two-year outcomes following unprotected left main stenting with first vs. new-generation drug-eluting stents: the FINE registry. EuroIntervention. 2013;9(7):809-16.
  • 10
    Sant'Anna FM, Batista LA, Brito MB, Menezes S, Ventura FM, Buczynski L, et al. Estudo randomizado e comparativo da intervenção coronária percutânea com stents recobertos por titânio-óxido nítrico ou de Aço Inoxidável em pacientes com doença arterial coronária: estudo RIO. Rev Bras Cardiol Invasiva. 2009;17(1):69-75.
  • 11
    Angioi M, Barragan P, Cattan S, Collet F, Dupouy P, Durand P, et al. French Ministry of Health prospective multicentre study using bio-active stents coated with titanium nitride oxide: the EVIDENCE registry. Arch Cardiovas Dis. 2012;105(2):60-7.
  • 12
    Karjalainen P, Ylitalo A, Juhani Airaksinen KE. Titanium and nitride oxide coated stents and paclitaxel eluting stents for coronary revascularization in an unselected population. J Invasive Cardiol. 2006;18(10):462-8.
  • 13
    Karjalainen P, Ylitalo A, Juhani Airaksinen KE. Real world experience with TITAN® stent: a 9-month follow-up report from the Titan PORI Registry. EuroIntervention. 2006;2(2):187-91.
  • 14
    Giraud-Sauveur Y. TITAN 2 Bio-active stent (BAS) with titanium-NO. EuroIntervention. 2008;3(4):526-8.
  • 15
    Karjalainen P. Titan 2 Stent vs. Xience V Stent: 18-month follow-up of the BASE-ACS Randomized Trial [Internet]. [cited 2014 Apr 12]. Available from: http://www.pcronline.com/ Lectures/2012
    » http://www.pcronline.com/ Lectures/2012
  • 16
    Romppanen H, Nammas W, Kervinen K, Mikkelsson J, Pietilä M, Lalmand J, et al. Outcome of ST-elevation myocardial infarction versus non-ST-elevation acute coronary syndrome treated with titanium-nitride-oxide-coated versus everolimuseluting stents: insights from the BASE-ACS trial. Minerva Cardioangiol. 2013;61(2):201-9.
  • 17
    Limacher A, Räber L, Laube E, Lauterburg A, Lötscher S, Hess N, et al. Clinical long-term outcome after implantation of titanium nitride-oxide coated stents compared with paclitaxel- or sirolimus-eluting stents: propensity-score matched analysis. EuroIntervention. 2012;7(9):1043-50.
  • 18
    Karjalainen PP, Niemelä M, Airaksinen JK, Rivero-Crespo F, Romppanen H, Sia J, et al. A prospective randomised comparison of titanium-nitride-oxide-coated bioactive stents with everolimus-eluting stents in acute coronary syndrome: the BASE-ACS trial. EuroIntervention. 2012;8(3):306-15.
  • 19
    Gubolino LA, Mangione JA, Silva SS, Queiroga MAC, Marin-Neto JA. Sociedade Brasileira de Cardiologia. Diretrizes da Sociedade Brasileira de Cardiologia sobre Qualidade Profissional e Institucional, Centro de Treinamento e Certificação Profissional em Hemodinâmica e Cardiologia Intervencionista - III Edição -2013. Arq Bras Cardiol. 2013;101Supl. 4:1-58.
  • 20
    Harold JG, Bass TA, Bashore TM, Brindis RG, Brush JE Jr, Burke JA, et al. ACCF/AHA/SCAI 2013 update of the clinical competence statement on coronary artery interventional procedures: a report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training (Writing Committee to Revise the 2007 Clinical Competence Statement on Cardiac Interventional Procedures). J Am Coll Cardiol. 2013;62(4):357-96.
  • 21
    Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al.; Academic Research Consortiun. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115(17):2344-51
  • 22
    Mosseri M, Miller H, Tamari I, Plich M, Hasin Y, Brizines M, et al. The Titanium-NO Stent: results of a multicenter registry. EuroIntervention. 2006;2(2):192-6.
  • 23
    Steinemann SG. Metal implants and surface reactions. Injury. 1996;27 Suppl 3:SC16-22.
  • 24
    van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes DR, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation. 1996; 94(7):1690-7.
  • 25
    Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, et al. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005;111(20):2617-22.
  • 26
    Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, et al. Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001; 104(8):928-33.
  • 27
    Moschovitis A, Simon R, Seidenstücker A, Klauss V, Baylacher M, Lüscher TF, et al. Randomized comparison of titanium-nitride-oxide coated stents with bare metal stents: five year follow-up of the TiNOX trial. EuroIntervention. 2010;6(1):63-8.
  • 28
    López-Mínguez JR, Nogales-Asensio JM, Doncel-Vecino LJ, Merchán-Herrera A, Pomar-Domingo F, Martínez-Romero P, et al. A Randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results. Rev Esp Cardiol. 2014 Apr 3. [Epub ahead of print].
Correspondence to: Wilson Albino Pimentel Filho. Hospital Beneficência Portuguesa de São Paulo − Rua Maestro Cardim, 769 − Bela Vista − CEP: 01323-900 − São Paulo, SP, Brazil. E-mail: wilpm@uol.com.br
CONFLICTS OF INTEREST
The authors declare no conflicts of interest.
  • FUNDING SOURCE
    None.

Publication Dates

  • Publication in this collection
    Apr-Jun 2014

History

  • Received
    02 Feb 2014
  • Accepted
    22 May 2014
Sociedade Brasileira de Hemodinâmica e Cardiologia Intervencionista - SBHCI R. Beira Rio, 45, 7o andar - Cj 71, 04548-050 São Paulo – SP, Tel. (55 11) 3849-5034, Fax (55 11) 4081-8727 - São Paulo - SP - Brazil
E-mail: sbhci@sbhci.org.br