Acessibilidade / Reportar erro

Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis

Abstract

Background:

Tracheal intubation in patients with coronavirus disease-19 is a high-risk procedure that should be performed with personal protective equipment (PPE). The influence of PPE on operator’s performance during tracheal intubation remains unclear.

Methods:

We conducted a systematic review and meta-analysis of simulation studies to evaluate the influence of wearing PPE as compared to standard uniform regarding time-to-intubation (TTI) and success rate. Subgroup analyses were conducted according to device used and operator’s experience.

Results:

The TTI was prolonged when wearing PPE (eight studies): Standard Mean Difference (SMD)-0.54, 95% Confidence Interval [-0.75,-0.34], p < 0.0001. Subgroup analyses according to device used showed similar findings (direct laryngoscopy, SMD-0.63 [-0.88,-0.38], p < 0.0001; videolaryngoscopy, SMD-0.39 [-0.75,-0.02], p = 0.04). Considering the operator’s experience, non-anesthesiologists had prolonged TTI (SMD-0.75 [-0.98,-0.52], p < 0.0001) while the analysis on anesthesiologists did not show significant differences (SMD-0.25 [-0.51, 0.01], p = 0.06). The success rate of tracheal intubation was not influenced by PPE: Risk Ratio (RR) 1.02 [1.00, 1.04]; p = 0.12). Subgroup analyses according to device demonstrated similar results (direct laryngoscopy, RR 1.03 [0.99, 1.07], p = 0.15, videolaryngoscopy, RR 1.01 [0.98, 1.04], p = 0.52). Wearing PPE had a trend towards negative influence on success rate in non-anesthesiologists (RR 1.05 [1.00, 1.10], p = 0.05), but not in anesthesiologists (RR 1.00 [0.98, 1.03], p = 0.84). Trial-sequential analyses for TTI and success rate indicated robustness of both results.

Conclusions:

Under simulated conditions, wearing PPE delays the TTI as compared to dressing standard uniform, with no influence on the success rate. However, certainty of evidence is very low. Performing tracheal intubation with direct laryngoscopy seems influenced to a greater extent as compared to videolaryngoscopy. Similarly, wearing PPE affects more the non-anesthesiologists subgroup as compared to anesthesiologists.

KEYWORDS
Direct laryngoscopy; Videolaryngoscopy; Anesthesiologists; Paramedics; Time to intubation; Success rate

Introduction

At the beginning of May 2021 the coronavirus disease 2019 (COVID-19) pandemic has approached almost 165 million diagnosed cases in 191 countries/regions, causing over 3.300.000 deaths according to the data from the Center for Systems Science and Engineering at Johns Hopkins University.11 Center for Systems Science and Engineering at Johns Hopkins University. COVID-19 Map. Available from: https://coronavirus.jhu.edu/map.html [Accessed 17 Jan 2021].
https://coronavirus.jhu.edu/map.html...
It has been estimated that around 2% of patients with COVID-19 will eventually require tracheal intubation for acute respiratory failure.22 Guan WJ, Ni ZY, Hu Y, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. 2020;382:1708-20.

A cornerstone in the management of COVID-19 pandemic has been the use of personal protective equipment (PPE) in order to ensure adequate protection to healthcare staff. Indeed, COVID-19 is a highly contagious disease and all maneuvers spreading aerosol particles (such as tracheal intubation) are considered as high-risk procedures for contamination of healthcare personnel. During the 2003 Severe Acute Respiratory Syndrome epidemic, Loeb et al. identified the following activities at high-risk for contagion in healthcare professionals: performing and assisting for tracheal intubation, suctioning before intubation, manipulating the oxygen mask.33 Loeb M, McGeer A, Henry B, et al. SARS among critical care nurses, Toronto. Emerg Infect Dis. 2004;10:251-5. Such risks were subsequently confirmed by a systematic review.44 Tran K, Cimon K, Severn M, et al. Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: a systematic review. PloS one. 2012;7:e35797.

In the attempt to safely manage airways of COVID-19 patients and to minimize the risk of viral transmission, several recommendations have been issued in the course of the current pandemic.55 Yao W, Wang T, Jiang B, et al. Emergency tracheal intubation in 202 patients with COVID-19 in Wuhan, China: lessons learnt and international expert recommendations. Br J Anaesth. 2020;125:e28-37.

6 Cook TM, El-Boghdadly K, McGuire B, et al. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists. Anaesthesia. 2020;75:785-99.
-77 Orser BA. Recommendations for endotracheal intubation of COVID-19 patients. Anesth Analg. 2020;130:1109-10. Among these, experts have suggested to wear full PPE and to use a videolaryngoscope (VLS) already at the first tracheal intubation attempt, possibly using a device with distant screen in order to enable further distancing of the operators from the patient’s mouth. Of note, these recommendations are mostly based on a theoretical background and on the experience acquired during present55 Yao W, Wang T, Jiang B, et al. Emergency tracheal intubation in 202 patients with COVID-19 in Wuhan, China: lessons learnt and international expert recommendations. Br J Anaesth. 2020;125:e28-37. and previous88 Caputo KM, Byrick R, Chapman MG, et al. Intubation of SARS patients: infection and perspectives of healthcare workers. Can J Anaesth. 2006;53:122-9. pandemics. However, there is currently no strong evidence supporting these recommendations and it remains unclear if VLS is truly the best choice. Moreover, it remains uncertain if the use of PPE has different impact on tracheal intubation according to the operator’s experience. Therefore, several aspects pertaining the approach to tracheal intubation during a pandemic need to be systematically addressed.

Whilst it seems likely that the indispensable use of PPE under hazardous conditions may render airway management more challenging due to operator’s constraints, one study reported faster performance by operators wearing PPEs as compared to their results whilst dressing in standard uniform.99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6. Moreover, several other studies showed neutral findings.1010 Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13.

11 Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.
-1212 Wang CC, Chaou CH, Tseng CY, et al. The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study. Eur J Emerg Med. 2016;23:124-9. In light of the above considerations, we thought it was urgent to pool the results of the available evidence. Therefore, we conducted a systematic review and a meta-analysis of simulation studies to evaluate the impact of wearing PPE as compared to standard uniform, both in term of time to intubation (TTI) and of success of the procedure, with sub-analyses conducted according to the type of device used or to the operator’s experience.

Methods

This systematic review and meta-analysis is reported in accordance with PRISMA guidelines.1313 Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62:e1-34. A protocol was written before starting the current review but the registration with the international prospective register of systematic reviews (PROSPERO) was not feasible as the register itself does not currently consider systematic reviews and meta-analyses on simulation studies.

Eligibility criteria

We included prospective studies conducted in simulated adult scenarios where participants with any level of experience in airway management performed tracheal intubation both under standard uniform dressing and whilst wearing any level of PPE. Regarding the simulation scenarios, we decided to include prospective simulated studies performed both on manikins or cadavers, and irrespectively of a normal or difficult airway scenario. The outcomes of interest were TTI and success rate (see Supplementary Digital Content 1 for PICOS criteria - Population, Intervention, Comparison, Outcomes, Study design).

Exclusion criteria

Studies including a population below 10 participants were considered for sensitivity analyses only. Paediatric studies were excluded. We applied a language restriction and only articles providing an abstract and published in the English language were considered for inclusion.

Search strategy

Two systematic independent literature searches of the electronic databases were performed through the NHS Healthcare Databases Advanced Search. We systematically searched the PubMed, MedLine, and EMBASE databases with the last update on September 3rd, 2020; the searches consisted of the combination of the MESH term ‘‘airway’’ with at least one term from each of two groups: 1) ‘‘simulat*’’ or ‘‘manikin*’’ or ‘‘mannequin*’’, and 2) ‘‘protective equipment’’ or ‘‘CBRN’’ (Chemical, Biological, Radiological, and Nuclear hazards) or ‘‘protective clothing’’ or ‘‘PPE’’ or ‘‘biohazard’’ or ‘‘protective gear’’ for the second group. A further independent manual search was performed by two authors (ST, VLR).

Study selection and data extraction

Two pairs of assessors screened the titles and abstracts for suitability (FS, ST, VLR, PM), with a fifth assessor (MA) arbitrating any disagreements. Full text articles identified as potentially relevant were assessed against PICOS criteria. Discrepancies were resolved by consensus and/or by involving another author (MA). All the authors conducted also an independent search on PubMed to check for further evidence. Two reviewers (ST, VLR) independently extracted data from individual studies and entered information into a pre-designed data collection form, which was cross-checked by two other authors (FS, PM). If needed, we planned to contact the corresponding authors to get more data.

Synthesis of evidence and outcomes of interest

The two primary outcomes were time-to-intubation (TTI) and success rate of the intubation procedure. These outcomes were considered for participants performing tracheal intubation wearing any type of PPE as compared to standard work dressing. In this regard, it must be noted that the level of protection offered by PPEs varies. In fact, PPEs have been classified by the Environmental Protection Agency and by the Occupational Safety and Health Administration into four levels of protection,1414 Classification of personal protective equipment according to the Environmental Protection Agency (EPA) and the Occupational Safety and Health Administration (OSHA): https://www.remm.nlm.gov/ppeclassification.htm. [Accessed on 17 September 2020].
https://www.remm.nlm.gov/ppeclassificati...
,1515 Classification of personal protective equipment according to the Environmental Protection Agency (EPA) and the Occupational Safety and Health Administration (OSHA): https://www.osha.gov/laws-regs/mou/1991-02-13 [Accessed on 17 September 2020].
https://www.osha.gov/laws-regs/mou/1991-...
each one identified by a capital letter (A, B, C, D). The level A PPE offers the highest protection, whilst level D identifies the standard uniform (standard precautions for healthcare professionals as gloves, splash protection, etc.). Details of PPE level are provided as Supplementary Digital Content 2. For each study, we evaluated in detail the equipment worn by participants before confirming the level of PPE. Despite apparent differences in PPE levels and in the protection offered, they all increase constraints and discomfort for the operator. For such reason, and because we expected a relatively low number of prospective studies with a heterogeneous design regarding devices and operator’s experience,1616 Sanfilippo F, Tigano S, Palumbo GJ, et al. Systematic review of simulated airway management whilst wearing personal protective equipment. Br J Anaesth. 2020;125:e301-5. we preventively decided to perform the primary analysis grouping all the PPE levels (A, B, and C) as compared to standard uniform (level D).

Subgroup and secondary analyses

Subgroup analyses of the outcomes of interest (TTI, success rate) were conducted separating studies results according to: a) the type of device used, or b) the operator’s experience. Regarding the type of device, we divided data of participants in those performing tracheal intubation with direct laryngoscopy (DL, with or without the use of aids) or with a VLS. In case of studies where DL was performed both alone or with the use of aids (i.e., stylet, bougie), we included only the DL without use of aids. In the second subgroup analysis, we separated studies where all participants were anaesthesiologists (or anesthesiology residents) from those where the population was mostly represented by nonanaesthesiologists. In particular, in the case of a study with a mixed population, it was classified in the subgroup of nonanaesthesiologists if the anaesthesiologists were less than 50% of the study population.

We also performed secondary analyses. As discussed, PPEs are classified into 3 levels (A, B, C). In the secondary analyses, we repeated the analyes for TTI and success rate separating studies according to the type of PPE. Thus, we performed three secondary analyses. Another secondary analysis was performed pooling together the PPE of level A and B, as we judged similar the level of discomfort/constraint caused by them (main difference is that PPE level A is fully encapsulating, while B is not).

Statistical analysis, heterogeneity, risk of bias, quality of assessment, and publication bias

Number of participants, mean values, and standard deviation were collected for the outcome analysis of TTI. If data were reported only as median and interquartile range or confidence interval (CI), we followed the approaches suggested by Luo et al.1717 Luo D, Wan X, Liu J, et al. Optimally estimating the sample mean from the sample size, median, mid-range, and/or mid-quartile range. Stat Methods Med Res. 2018;27:1785-805. and Wan et al.1818 Wan X, Wang W, Liu J, et al. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014;14:135. For the analysis of the success rate, we collected the number of attempts and the success at first attempt. A random effect model was used, the continuous outcome (TTI) and the categorical variable (success rate) differences were analyzed using the inverse variance method with a 95%CI. Values for TTI are reported as standard mean difference (SMD), while success rate is reported according to Risk Ratio (RR); p-values were two-tailed and considered significant if p < 0.05.

The presence of statistical heterogeneity was assessed using the X22 Guan WJ, Ni ZY, Hu Y, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. 2020;382:1708-20. (Cochran Q) test. Heterogeneity was likely if Q > df (degrees of freedom) and confirmed if p ≤ 0.10. Quantification of heterogeneity was performed using I2 statistic. Values of 0-24.9%, 25-49.9%, 50-74.9%, and > 75% were considered as none, low, moderate, and high heterogeneity, respectively. Meta-analysis was performed using review manager (Revman, Version 5.4. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014).

As already performed in other meta-analyses in the field of anesthesiology,1919 Julien-Marsollier F, Michelet D, Bellon M, et al. Muscle relaxation for tracheal intubation during paediatric anaesthesia: a meta-analysis and trial sequential analysis. Eur J Anaesthesiol. 2017;34:550-61.,2020 Vanlinthout LE, Geniets B, Driessen JJ, et al. Neuromuscularblocking agents for tracheal intubation in pediatric patients (0-12 years): a systematic review and meta-analysis. Paediatr Anaesth. 2020;30:401-14. we conducted trial-sequential analyses (TSAs) and assessment of the quality of evidence of our findings. In particular, we performed the TSA in order to evaluate the effect of random error and calculate the information size (the power of the meta-analysis) for the overall analyses of TTI and success rate. We used the freely-available TSA Software (Copenhagen Trial Unit’s TSA Software®; Copenhagen, Denmark). The information size was computed assuming an alpha risk of 5%, a beta risk of 20%. The estimated effects (RR and SMD) were computed averaging results of the classical meta-analysis method. Further details on TSA and its interpretation are available elsewhere.2121 Afshari A, Wetterslev J. When may systematic reviews and meta-analyses be considered reliable? Eur J Anaesthesiol. 2015;32:85-7.

There were no deviations from the protocol. The risk of bias was performed using the RoB 2.0 for ‘‘Individuallyrandomized, cross-over trials’’2222 A revised tool to assess risk of bias in randomized trials (RoB 2.0). https://www.bristol.ac.uk/population-health-sciences/centres/cresyda/barr/riskofbias/rob2-0/. [Accessed 27 March 2021].
https://www.bristol.ac.uk/population-hea...
which was deemed the most appropriate after consultation with senior statisticians. Publication bias was investigated by visual inspection of funnel plots for the primary outcomes. The quality of evidence was generated in accordance with the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group. Using the GRADEpro online software, we performed a summary of the overall analyses in order to assess the quality and certainty of evidence for each outcome (pooled data expressed as SMD or RR).2323 Alonso-Coello P, Oxman AD, Moberg J, Brignardello-Petersen R, Akl EA, Davoli M, et al. GRADE Evidence to Decision (EtD) frameworks: a systematic and transparent approach to making well informed healthcare choices. 2: clinical practice guidelines. BMJ (Clin Res Ed). 2016;353:i2089.

24 Andrews JC, Schünemann HJ, Oxman AD, et al. GRADE guidelines: 15. Going from evidence to recommendationdeterminants of a recommendation’s direction and strength. J Clin Epidemiol. 2013;66:726-35.
-2525 Guyatt GH, Oxman AD, Vist GE, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ (Clin Res Ed). 2008;336:924-6. The flow of references was managed with the Endnote X7 citation manager.

Results

The two independent literature searches produced 31 titles on Medline, 48 on PubMed, and 51 on EMBASE. The PRISMA flowchart of the systematic search and qualitative synthesis is reported as Figure 1. After removal of duplicates and after screening of titles and abstracts, 17 articles were considered of interest. Six were excluded because participants performed simulated tracheal intubation wearing PPEs but not under a standard uniform (missing control group). Two other studies were excluded for not reporting the data required (we contacted twice the corresponding author without success). Therefore, we finally included 9 studies. Of these, one was a four-arm study (controls, PPE A, B, and C),1010 Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13. another evaluated tracheal intubation with both levels B and C PPEs as compared with controls.99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6. Of the remaining seven studies, five compared level C PPEs to standard uniform,1111 Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.,1212 Wang CC, Chaou CH, Tseng CY, et al. The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study. Eur J Emerg Med. 2016;23:124-9.,2626 Burns JB Jr, Branson R, Barnes SL, et al. Emergency airway placement by EMS providers: comparison between the King LT supralaryngeal airway and endotracheal intubation. Prehosp Disaster Med. 2010;25:92-5.

27 Scott Taylor R, Pitzer M, Goldman G, et al. Comparison of intubation devices in level C personal protective equipment: a cadaveric study. Am J Emerg Med. 2018;36:922-5.
-2828 Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31. and two involved the use of level A PPEs.2929 Castle N, Pillay Y, Spencer N. What is the optimal position of an intubator wearing CBRN-PPE when intubating on the floor: a manikin study. Resuscitation. 2011;82:588-92.,3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. All studies performed tracheal intubation with DL (± aids), one included also attempts with a McCoy laryngoscope,3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. and five performed tracheal intubation with VLS(s).99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.,1111 Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.,2727 Scott Taylor R, Pitzer M, Goldman G, et al. Comparison of intubation devices in level C personal protective equipment: a cadaveric study. Am J Emerg Med. 2018;36:922-5.,2828 Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31.,3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. As shown in Table 1, data extracted from each study included the PPE level, the type of device(s) used for tracheal intubation, operator’s experience, and the outcome(s) of interest reported.

Figure 1
PRISMA flowchart.

Table 1
Characteristics of the included studies.

Outcome analyses - TTI

Eight studies reported the TTI comparing simulated procedure performed both dressing standard uniform (controls) and wearing PPE.99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.

10 Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13.

11 Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.
-1212 Wang CC, Chaou CH, Tseng CY, et al. The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study. Eur J Emerg Med. 2016;23:124-9.,2626 Burns JB Jr, Branson R, Barnes SL, et al. Emergency airway placement by EMS providers: comparison between the King LT supralaryngeal airway and endotracheal intubation. Prehosp Disaster Med. 2010;25:92-5.,2828 Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31.

29 Castle N, Pillay Y, Spencer N. What is the optimal position of an intubator wearing CBRN-PPE when intubating on the floor: a manikin study. Resuscitation. 2011;82:588-92.
-3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. In particular, regarding the intervention group, seven studies reported data on level C PPE, two with level B, and three level A.

The primary outcome analysis (pooling together results from all levels of PPEs) showed that tracheal intubation was significantly shorter wearing standard uniform (SMD - 0.54, 95%CI [-0.75,-0.34], p < 0.0001, I2 = 69%; 19 studies, 1306 procedures; very low certainty of evidence). As shown in Fig. 2, we found no subgroup differences according to the device used for tracheal intubation, being TTI shorter with standard uniform using both DL (SMD-0.63, 95%CI [- 0.88,-0.38]; p < 0.0001, I2 = 69%) or VLS (SMD-0.39, 95%CI [-0.75,-0.02]; p = 0.04, I2 = 72%). As shown in Supplementary Digital Content 3, when dividing subgroups according to the operator’s experience, anesthesiologists had a nonsignificant trend towards shorter TTI whilst wearing standard uniform (SMD-0.25, 95%CI [-0.51, 0.01]; p = 0.06, I2 = 72%). Conversely, in the subgroup of non-anesthesiologists (which included also Garner et al.1010 Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13. where 2 out of 16 participants were anesthesiologists) the TTI was significantly shorter wearing standard uniform as compared to PPE (SMD-0.75, 95%CI [-0.98,-0.52]; p < 0.0001, I2 = 61%).

Figure 2
Forest plot comparing the Time to Intubation wearing standard uniform as compared with personal protective equipment (PPE) of level A, B, or C. Subgroups are divided according to the type of device used for the tracheal intubation.

In order to provide more clinical sense of potential delay of intubation under the constraints of wearing PPE, we also calculated the weighted means from the groups. We found that weighted TTI was on average prolonged by 11.3 seconds when wearing PPE uniform (38.8 vs. 27.5 seconds in the standard uniform).

Outcome analyses - success rate

Seven studies reported the success rate during simulated attempts of tracheal intubation performed by participants dressing standard uniform (controls) and wearing PPE(s).99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.,1111 Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.,1212 Wang CC, Chaou CH, Tseng CY, et al. The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study. Eur J Emerg Med. 2016;23:124-9.,2727 Scott Taylor R, Pitzer M, Goldman G, et al. Comparison of intubation devices in level C personal protective equipment: a cadaveric study. Am J Emerg Med. 2018;36:922-5.

28 Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31.

29 Castle N, Pillay Y, Spencer N. What is the optimal position of an intubator wearing CBRN-PPE when intubating on the floor: a manikin study. Resuscitation. 2011;82:588-92.
-3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. We pooled data from five studies where participants worn level C PPE, one where they dressed level B PPE and two with level A PPE. The primary outcome analysis showed that wearing PPE did not significantly influence the success rate of tracheal intubation (RR 1.02, 95%CI [1.00, 1.04]; p = 0.12, I2 = 25%; 17 studies, 1192 procedures; very low certainty of evidence; Fig. 3). This finding was valid for both the use of DL (RR-1.03, 95%CI [0.99, 1.07]; p = 0.15, I2 = 49%) or VLS [(RR 1.01, 95%CI [0.98, 1.04]; p = 0.52, I2 = 0%).

Figure 3
Forest plot comparing the success rate of tracheal intubation wearing standard uniform as compared with personal protective equipment (PPE) of level A, B, or C. Subgroups are divided according to the type of device used for the tracheal intubation.

When the analysis was performed dividing subgroups according to the operator’s experience, we found that success rate in anesthesiologists was not influenced by wearing PPEs as compared to standard uniform (RR-1.00, 95%CI [- 0.98, 1.03]; p = 0.84, I2 = 0%). Conversely, the subgroup of ‘‘non-anesthesiologists’’ had a trend towards lower success rate when wearing PPEs (RR 1.05, 95%CI [1.00, 1.10]; p = 0.05, I2 = 57%, Supplementary Digital Content 4).

In order to provide more clinical understanding on the impact of wearing PPE on success rate at first attempt of the intubation procedure, we calculated the weighted success rates, which was, on average, almost 5% lower when wearing PPE uniform (93.6% vs. 98.5% in the standard uniform).

Trial-sequential analyses

The two TSA performed for the overall TTI and success rate showed similar results (Supplementary Digital Content 5 and 6, respectively). The TSA on the overall TTI crossed the trial sequential monitoring boundary, showing that meta-analysis results are well-powered. Indeed, the two-sided alphaspending boundary according to O’Brien-Fleming method showed that the number of intubation procedures needed to be included in the meta-analysis to reach the desired level of significance and power was 148, which was passed very early by the z-curve. Therefore, the result on TTI seems very robust and unlikely to be biased.

The z-curve on the overall success crossed the futility boundary and almost reached the required sample size of 1243 procedures. This indicates that the finding of no difference in success rate between standard uniform and PEE is robust and no further studies are needed.

Secondary analyses

Table 2 shows the results of the primary analyses on TTI and success rates together with the findings of the analyses conducted according to the level of PPE used. As the studies of Schumacher et al.99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6. and Garner et al.1010 Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13. compared the control group with two and three level of PPE respectively, we also conducted further post-hoc analyses of the primary outcomes considering one level of PPE only (vs. control group) for these two studies. None of these analyses changed the results.

Table 2
Summary of the results of the primary and secondary analyses comparing tracheal intubation wearing personal protective equipment (PPE) vs. standard uniform (control group).

Risk of bias, publication bias, and quality of evidence assessment

The assessment of the risk of bias performed with the RoB 2.0 showed that all studies were at high-risk (Supplementary Digital Content 7).

We investigated publication bias by visual inspection of funnel plots for the primary outcomes (Supplementary Digital Content 8). We found no evidence of publication bias regarding the TTI outcome. The success rate included a total of seventeen comparisons, with ten of them reporting a RR value of 1.00 and similar sample size. Therefore, several studies had an overlap on the funnel plot. Only one comparison of the three reported by Castle et al.3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. behaved as outlier (RR = 1.20, intubation with McCoy DL). Its exclusion did not change the overall and the subgroups’ results.

Quality of evidence generated in accordance with the GRADE Working Group resulted very low for both outcomes (Table 3), suffering from the high-risk of bias in the included studies and the indirectness of the simulation scenarios.

Table 3
Evaluation of quality of evidence according to Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group.

Discussion

We conducted a systematic review and meta-analysis with the aim of investigating whether performing tracheal intubation under the constraints of wearing PPE may worsen the operator’s performance, both in terms of TTI and success rate. The most important finding of our meta-analysis is that wearing PPE significantly prolonged the TTI without affecting the overall success rate of tracheal intubation as compared with standard uniform. The two TSAs showed that both analyses reached the appropriate information size. Therefore, wearing PPE prolongs the TTI without worsening the success rate of intubation with no further research required to confirm these findings. However, the high risk of bias in the included studies, the inconsistency due to the different level of experience in airway management across studies’ participants and the indirectness of findings due to the simulation environment contributed to the very low certainty of evidence for the two primary outcomes as assessed with the GRADEpro software. The larger effect size found for TTI allowed an upgrade of certainty of evidence.

From a clinical perspective, as the use of SMD and the RR are not entirely intuitive in describing to what extent PPE hinders tracheal intubation, we calculated the weighted means of TTI and success rate. On average, we found that PPE increased the TTI of about 11 seconds, whilst decreasing 5% the probability of success at first attempt. As guaranteeing the operators’ safety during intubation is certainly of utmost importance, our meta-analysis numerically supports that wearing PPE has a mild clinical impact on intubation practice.

We also performed subgroup analyses according to the device used for tracheal intubation or to the operator’s experience. The first subgroup analysis (taking into account the type of device used) confirmed that wearing PPE increases the TTI regardless of the device used. However, the delay in achieving tracheal intubation was longer using DL as compared with VLS (see values of SMD and relative 95%CI - weighted means around 13 s for DL and 9 s for VL). The success rate was not different between subgroups.

The other subgroup analysis was performed considering the experience in airway management. In this analysis, the TTI was significantly prolonged in operators with lower experience in airway management, whilst the impact on anesthesiologists did not reach a statistically significant result (p = 0.06). Regarding the success rate at first attempt, wearing PPE did not influence the performance of anesthesiologists, whilst a trend towards lower success rate in non-anesthesiologists was noted (p = 0.05).

Noteworthy, one should keep in mind that, among several limitations of pooling evidence from simulated scenarios, the included studies were not set up for difficult intubation. This setting deserves further investigations as, theoretically, the constraints of wearing PPE may further worsen performances in difficult airway scenarios. Nonetheless, despite these and other limitations (see dedicated paragraph), our meta-analysis provides some support to the current (and possibly future) guidelines developed on the airway management in highly hazardous conditions,55 Yao W, Wang T, Jiang B, et al. Emergency tracheal intubation in 202 patients with COVID-19 in Wuhan, China: lessons learnt and international expert recommendations. Br J Anaesth. 2020;125:e28-37.

6 Cook TM, El-Boghdadly K, McGuire B, et al. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists. Anaesthesia. 2020;75:785-99.
-77 Orser BA. Recommendations for endotracheal intubation of COVID-19 patients. Anesth Analg. 2020;130:1109-10. such as in COVID-19 patients. Current guidelines suggest that tracheal intubation procedure should be performed from the beginning with a VLS, also suggesting the use a VLS equipped with a distant screen to enable greater distance between the operator’s face and the patient’s mouth. As we did not find enough studies evaluating the use of VLS with distant screen, we could not investigate if this type of VLS offers better performances as compared to VLS with ‘‘screen-on-blade’’. Indeed, there was a large heterogeneity regarding the devices for tracheal intubation in the included simulation studies. Therefore, a quantitative analysis comparing the performances of each device was not reasonable, and we rather pooled studies in broad subgroups according to the type of device (DL or VLS). This results in a certain degree of clinical heterogeneity as in the subgroup DL were also included procedures performed with the aid of a stylet,1212 Wang CC, Chaou CH, Tseng CY, et al. The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study. Eur J Emerg Med. 2016;23:124-9.,2828 Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31. as well as results obtained with the use of McCoy blade.3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52. Similarly, we included in the VLS subgroup both studies performed with the device with screen attached (Pentax AWS2828 Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31. and Airtraq99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.,1111 Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.,3030 Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52.) or distant from the blade (Airtraq VL99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.). We acknowledge the heterogeneity of pooling together different levels of PPE, but this choice was justified by the expected (and confirmed) relatively low number of studies.

Though some analyses were not feasible due to the low number of studies, in the attempt to look for difference between PPE levels, we performed secondary analyses in this regard confirming the results of the primary outcomes. In particular, wearing PPE delays the TTI but does not affect the overall success rate of tracheal intubation. Moreover, the findings of subgroup analyses also seemed similar, with greater delay when tracheal intubation is performed with DL or by less experienced operators (non-anesthesiologists).

Of note, we excluded one study where the participants (anesthesiology consultants and residents) performed tracheal intubation with DL wearing various PPEs but the study did not include a control group (lower level of protection was equivalent to PPE level C3131 Greenland KB, Tsui D, Goodyear P, et al. Personal protection equipment for biological hazards: does it affect tracheal intubation performance? Resuscitation. 2007;74:119-26.).

Limitations

Our meta-analysis has several limitations. First, the studies presented heterogeneity in the definition of TTI, and the chronometer count did not have the same start-point for all the studies. Moreover, not all studies were clear on the TTI calculation in case of failure. In such instance, authors have two main options: 1) calculate the TTI averaging only the time taken for successful intubations, or 2) also counting the time for failed procedures attributing a ‘‘failure time’’ (pre-established cut-off) for each failed procedure. In other words, some studies explicitly reported in their design a predefined cut-off time to declare a failed tracheal intubation attempt (i.e., 120 seconds). In these cases, authors may have either counted the cut-off time for each failed attempt, or rather discarded the case. As in most cases authors were unclear in this regard, we preferred to use the overall number of participants for the calculation of the TTI. Since the success rates were similar between groups, we think that it is unlikely that the analysis was significantly biased by this reporting issue.

Second, the validity of subgroup analyses according to the operator experience is probably limited. Indeed, the group of anesthesiologists consisted of 55 participants only, whilst the experience in the remaining non-anesthesiologist participants was highly variable. Moreover, the betweenstudy heterogeneity cannot be fully corrected using a random-effects analysis. In this regard, one way to investigate the influence of factors contributing to the variability of study findings would have been to perform a meta-regression analysis accounting for operator experience (anesthesiologist or non-anesthesiologist), type of model for performing intubation (manikin or cadaver), positioning of the operator (lying or in upright position), and possibly others. We unfortunately don’t have the required skills to perform such advanced analysis and lack of meta-regression analysis is one limitation of our study.

Third, we investigated simulation studies and the included studies cannot account for all the human factors involved in the airways management of patients with highly infectious diseases, such as COVID-19. Indeed, while some factors are potentially accounted also in simulation studies as related to the uniform itself, other issues that may influence the operator performance (such as the fear of self-contamination with a highly infectious disease)3232 Andrade EF, Pereira LJ, Oliveira APL, et al. Perceived fear of COVID-19 infection according to sex, age and occupational risk using the Brazilian version of the Fear of COVID-19 Scale. Death Stud. 2020:1-10.,3333 McKay D, Minaya C, Storch EA. Conducting exposure and response prevention treatment for contamination fears during COVID-19: The behavioral immune system impact on clinician approaches to treatment. J Anxiety Disord. 2020;74:102270. are probably not well-replicated by simulation environment. Moreover, in a computed tomography study, Schebesta et al. showed that manikins do not fully reflect the upper airways anatomy of actual patients.3434 Schebesta K, Hüpfl M, Rössler B, et al. Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers. Anesthesiology. 2012;116:1204-9. Therefore, the generalizability of our findings and those of all manikin studies is certainly limited.

Fourth, from a statistical perspective, the decision to pool together the studies regardless the level of PPE was dictated by the expectation of a low number of studies.3535 Sanfilippo F, Tigano S, Palumbo GJ, et al. Importance of inclusion criteria in systematic reviews. Br J Anaesth. 2020;125:E398-9. This means that for the two studies exploring more than one level of PPE,99 Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.,1010 Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13. the performances of tracheal intubation with each PPE level were plotted against the same control group. However, post-hoc analyses ruled out this issue.

Fifth, we found some difficulties in finding the best scale of evaluation for the risk of bias. After consultation with a senior statistician, we agreed that the RoB 2.0 for ‘‘Individually-randomized, cross-over trials’’ was the most appropriate.

Conclusion

In conclusion, under simulated conditions, wearing PPE prolongs the time to achieve successful tracheal intubation as compared to dressing in standard uniform, without influence on the success rate of the procedure. The influence of wearing PPE seems greater when performing tracheal intubation with DL as compared with VLS. The performance of anesthesiologists seem less influenced than of non-anesthesiologists. Although, the overall analyses are well-powered according to the TSA, the strength of our findings is heavily weakened by the high risk of bias in the included studies and the very low/low certainty of evidence found in the GRADE assessment. The clinical impact of our meta-analysis is weakened by the variability in the included studies regarding providers, PPE used, operator experience, and by the indirectness of findings due to the simulation setting.

The PRISMA checklist is provided as supplementary material.

Appendix A Supplementary data

Supplementary material related to this article can be found, in the online version, at doi:https://doi.org/10.1016/j.bjane.2021.08.017.

References

  • 1
    Center for Systems Science and Engineering at Johns Hopkins University. COVID-19 Map. Available from: https://coronavirus.jhu.edu/map.html [Accessed 17 Jan 2021].
    » https://coronavirus.jhu.edu/map.html
  • 2
    Guan WJ, Ni ZY, Hu Y, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. 2020;382:1708-20.
  • 3
    Loeb M, McGeer A, Henry B, et al. SARS among critical care nurses, Toronto. Emerg Infect Dis. 2004;10:251-5.
  • 4
    Tran K, Cimon K, Severn M, et al. Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: a systematic review. PloS one. 2012;7:e35797.
  • 5
    Yao W, Wang T, Jiang B, et al. Emergency tracheal intubation in 202 patients with COVID-19 in Wuhan, China: lessons learnt and international expert recommendations. Br J Anaesth. 2020;125:e28-37.
  • 6
    Cook TM, El-Boghdadly K, McGuire B, et al. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists. Anaesthesia. 2020;75:785-99.
  • 7
    Orser BA. Recommendations for endotracheal intubation of COVID-19 patients. Anesth Analg. 2020;130:1109-10.
  • 8
    Caputo KM, Byrick R, Chapman MG, et al. Intubation of SARS patients: infection and perspectives of healthcare workers. Can J Anaesth. 2006;53:122-9.
  • 9
    Schumacher J, Arlidge J, Dudley D, et al. The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study. Anaesthesia. 2020;75:1301-6.
  • 10
    Garner A, Laurence H, Lee A. Practicality of performing medical procedures in chemical protective ensembles. Emerg Med Austral. 2004;16:108-13.
  • 11
    Plazikowski E, Greif R, Marschall J, et al. Emergency airway management in a simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39:145-51.
  • 12
    Wang CC, Chaou CH, Tseng CY, et al. The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study. Eur J Emerg Med. 2016;23:124-9.
  • 13
    Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62:e1-34.
  • 14
    Classification of personal protective equipment according to the Environmental Protection Agency (EPA) and the Occupational Safety and Health Administration (OSHA): https://www.remm.nlm.gov/ppeclassification.htm [Accessed on 17 September 2020].
    » https://www.remm.nlm.gov/ppeclassification.htm
  • 15
    Classification of personal protective equipment according to the Environmental Protection Agency (EPA) and the Occupational Safety and Health Administration (OSHA): https://www.osha.gov/laws-regs/mou/1991-02-13 [Accessed on 17 September 2020].
    » https://www.osha.gov/laws-regs/mou/1991-02-13
  • 16
    Sanfilippo F, Tigano S, Palumbo GJ, et al. Systematic review of simulated airway management whilst wearing personal protective equipment. Br J Anaesth. 2020;125:e301-5.
  • 17
    Luo D, Wan X, Liu J, et al. Optimally estimating the sample mean from the sample size, median, mid-range, and/or mid-quartile range. Stat Methods Med Res. 2018;27:1785-805.
  • 18
    Wan X, Wang W, Liu J, et al. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014;14:135.
  • 19
    Julien-Marsollier F, Michelet D, Bellon M, et al. Muscle relaxation for tracheal intubation during paediatric anaesthesia: a meta-analysis and trial sequential analysis. Eur J Anaesthesiol. 2017;34:550-61.
  • 20
    Vanlinthout LE, Geniets B, Driessen JJ, et al. Neuromuscularblocking agents for tracheal intubation in pediatric patients (0-12 years): a systematic review and meta-analysis. Paediatr Anaesth. 2020;30:401-14.
  • 21
    Afshari A, Wetterslev J. When may systematic reviews and meta-analyses be considered reliable? Eur J Anaesthesiol. 2015;32:85-7.
  • 22
    A revised tool to assess risk of bias in randomized trials (RoB 2.0). https://www.bristol.ac.uk/population-health-sciences/centres/cresyda/barr/riskofbias/rob2-0/ [Accessed 27 March 2021].
    » https://www.bristol.ac.uk/population-health-sciences/centres/cresyda/barr/riskofbias/rob2-0/
  • 23
    Alonso-Coello P, Oxman AD, Moberg J, Brignardello-Petersen R, Akl EA, Davoli M, et al. GRADE Evidence to Decision (EtD) frameworks: a systematic and transparent approach to making well informed healthcare choices. 2: clinical practice guidelines. BMJ (Clin Res Ed). 2016;353:i2089.
  • 24
    Andrews JC, Schünemann HJ, Oxman AD, et al. GRADE guidelines: 15. Going from evidence to recommendationdeterminants of a recommendation’s direction and strength. J Clin Epidemiol. 2013;66:726-35.
  • 25
    Guyatt GH, Oxman AD, Vist GE, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ (Clin Res Ed). 2008;336:924-6.
  • 26
    Burns JB Jr, Branson R, Barnes SL, et al. Emergency airway placement by EMS providers: comparison between the King LT supralaryngeal airway and endotracheal intubation. Prehosp Disaster Med. 2010;25:92-5.
  • 27
    Scott Taylor R, Pitzer M, Goldman G, et al. Comparison of intubation devices in level C personal protective equipment: a cadaveric study. Am J Emerg Med. 2018;36:922-5.
  • 28
    Shin DH, Choi PC, Na JU, et al. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin. Emerg Med J. 2013;30:527-31.
  • 29
    Castle N, Pillay Y, Spencer N. What is the optimal position of an intubator wearing CBRN-PPE when intubating on the floor: a manikin study. Resuscitation. 2011;82:588-92.
  • 30
    Castle N, Pillay Y, Spencer N. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study. Resuscitation. 2011;82:1548-52.
  • 31
    Greenland KB, Tsui D, Goodyear P, et al. Personal protection equipment for biological hazards: does it affect tracheal intubation performance? Resuscitation. 2007;74:119-26.
  • 32
    Andrade EF, Pereira LJ, Oliveira APL, et al. Perceived fear of COVID-19 infection according to sex, age and occupational risk using the Brazilian version of the Fear of COVID-19 Scale. Death Stud. 2020:1-10.
  • 33
    McKay D, Minaya C, Storch EA. Conducting exposure and response prevention treatment for contamination fears during COVID-19: The behavioral immune system impact on clinician approaches to treatment. J Anxiety Disord. 2020;74:102270.
  • 34
    Schebesta K, Hüpfl M, Rössler B, et al. Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers. Anesthesiology. 2012;116:1204-9.
  • 35
    Sanfilippo F, Tigano S, Palumbo GJ, et al. Importance of inclusion criteria in systematic reviews. Br J Anaesth. 2020;125:E398-9.

Publication Dates

  • Publication in this collection
    28 Feb 2022
  • Date of issue
    Mar-Apr 2022

History

  • Received
    18 Jan 2021
  • Accepted
    28 Aug 2021
Sociedade Brasileira de Anestesiologia (SBA) Rua Professor Alfredo Gomes, 36, Botafogo , cep: 22251-080 - Rio de Janeiro - RJ / Brasil , tel: +55 (21) 97977-0024 - Rio de Janeiro - RJ - Brazil
E-mail: editor.bjan@sbahq.org