Acessibilidade / Reportar erro
Arquivos Brasileiros de Cardiologia, Volume: 73, Número: 2, Publicado: 1999
  • Invasive hemodynamic monitoring in the postoperative period of cardiac surgery Original Articles

    Dragosavac, Desanka; Araújo, Sebastião; Carieli, Maria do Carmo Monteiro; Terzi, Renato G. G.; Dragosavac, Sanja; Vieira, Reinaldo Wilson

    Resumo em Inglês:

    OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP). METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI), systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI), and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2) and consumption (VO2), p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS). Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.
  • Results of the surgical treatment of chronic atrial fibrillation Original Articles

    Kalil, Renato A. K.; Albrecht, Álvaro; Lima, Gustavo G.; Vasconcellos, Daniela; Cunha, Bartira; Hatem, Domingos; Moreno, Paulo; Abrahão, Rogério; Sant'Anna, João R. M.; Prates, Paulo R.; Nesralla, Ivo A.

    Resumo em Inglês:

    OBJECTIVE: Report clinical experience in surgical treatment of atrial fibrillation (AF) by Cox-maze procedure. METHODS: 61 patients underwent surgical treatment for AF. Two had primary AF and 59 AF secondary to heart disease (2 atrial septal defects, 57 mitral). Ages ranged from 20 to 74 years (mean = 49). There were 44 females (72%). The surgical technique employed was Cox 3 without cryoablation. The patients were follow-up in specific at patient clinics and underwent periodical ECG, exercise tests, echocardiogram and Holter monitoring. RESULTS: In-hospital mortality was 4.9% and late mortality 1.6%. A temporary pacemaker was used in 28 (46%) and a definitive in 7 patients (11.4%). On hospital discharge, AF remained in 17%; 63.9% had sinus rhythm, 6.9% atrial rhythm, 1.7% junctional rhythm, and 10.3% had pacemaker rhythm. In the last evaluation, AF was present in 19.5%; (70.5% sinus rhythm, 4% atrial rhythm, 2% atrial tachycardia, and 4% pacemaker rhythm). There was no report of thromboembolic episodes. Chronotropic response was considered adequate in 19%, intermediate in 29%, and inadequate in 42%. In Holter monitoring, the mean heart rate was 82±8 bpm, with a minimum of 57±7 bpm and maximum of 126±23 bpm, with supraventricular extrasystoles in 2.3±5.5% of the total heartbeats and ventricular extrasystoles in 0.8±0.5%. In the echocardiogram, the A wave was present in the left atrium in 87.5%. CONCLUSION: Maze procedure is effective and has acceptable surgical risk. Atrial or sinus rhythms remain stable with a small but remarkable frequency of atrial and ventricular arrhythmias. Left atrial contraction is present, although attenuated, as well as the chronotropic response to exercise.
  • In-stent restenosis. Acute and long-term outcomes after excimer laser coronary angioplasty Original Articles

    Bejarano, Jorge; Bermudez, Edgardo; Diaz, Pedro; Gallarello, Francesca; Margolis, James R.

    Resumo em Inglês:

    OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.
  • Doppler echocardiographic evaluation of HIV-positive patients in different stages of the disease Original Articles

    Werneck, Guilherme Lobosco; Mesquita, Evandro Tinoco; Romêo Fº, Luiz José Martins; Ribeiro, Mario Luiz

    Resumo em Inglês:

    OBJETIVE: To evaluate by Doppler echocardiography (DE) early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A) and 25 with CD4 cell count <500/mm³ (Group B), were analyzed. CD4 cells were counted and matched with structural data and systolic and diastolic function of the left ventricle (LV), as analyzed by DE. The results were compared with those obtained in 47 healthy individuals (Group C). RESULTS: 8% of patients in Group B had mild pericardial effusion; 31.5% showed decreased systolic function of the LV, and 12% had moderate mitral regurgitation. A wave velocity from the mitral inflow was different among the 3 groups, being higher in Group B, where the deceleration time of the E wave of the mitral inflow and the E/A ratio were significantly lower with a normal value of the isovolumic relaxation time (IVRT). CONCLUSION: HIV-positive patients with a CD4 cell count >500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³), had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.
  • Ventricular evoked response in patients with hypertrophic obstructive cardiomyopathy treated with DDD pacing Original Articles

    Sant'Anna, João Ricardo M.; Prati, Raquel; Hutten, Helmut; Schreier, Günter; Kastner, Peter; Kalil, Renato A. K.; Prates, Paulo R.; Castro, Iran; Azambuja, Paulo C.; Faes, Farid; Nesralla, Ivo A.; Schaldach, Max

    Resumo em Inglês:

    OBJECTIVE: To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS: A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the following conditions were assessed: 1) Baseline evaluation: different AV delay (ranging from 150ms to 50 ms) were sequentially programmed during 5 to 10 minutes, and the LVOTG (as determined by Doppler echocardiography) and VER recorded; 2) standard evaluation, when the best AV delay (resulting in the lowest LVOTG) programmed at the initial evaluation was maintained so that its effect on VER and LVOTG could be assessed during each chronic pacing evaluation. RESULTS: LVOTG decreased after DDD pacing, with a mean value of 59 ± 24 mmHg after dual chamber pacemaker, which was significantly less than the gradient before pacing (98 + 22mmHg). An AV delay >100ms produced a significantly lower decrease in VER depolarization duration (VER DD) when compared to an AV delay <=100ms. Linear regression analyses showed a significant correlation between the LVOTG values and the magnitude of VER (r=0.69; p<0.05) in the 9 studied patients. CONCLUSION: The telemetry obtained intramyocardial electrogram is a sensitive means to assess left ventricular dynamics in patients with HOCM treated with DDD pacing.
  • Anomalous origin of the left coronary artery from the right pulmonary artery with intramural aortic trajectory. Clinicosurgical diagnostic implications Original Articles

    Atik, Edmar; Barbero-Marcial, Miguel; Tanamati, Carla; Kajita, Luis; Ebaid, Munir; Jatene, Adib

    Resumo em Inglês:

    OBJECTIVE: Anomalous origin of the left coronary artery from the right pulmonary artery (AOLCARPA), is a rare entity that is usually associated with other defects. Of the 20 cases of AOLCARPA reported in the literature, 14 (70%) had associations. We describe four patients with AOLCARPA without associated defects, but with a peculiar intramural aortic trajectory. METHODS: Fifty-five patients with anomalous origin of the left coronary artery were operated upon at INCOR-FMUSP. Four of the patients had the anomalous origin from the right pulmonary artery (RPA) without associated defects but with intramural aortic trajectory. Clinical and laboratory examinations were analyzed, as well as surgical findings. RESULTS: All patients had congestive heart failure (CHF) and 3 also had angina pectoris. Two patients had a murmur of mitral regurgitation, signs of myocardial infarction on the ECG and cardiomegaly. The shortening fraction varied from 9% to 23%. The hemodynamic study confirmed the diagnosis of anomalous origin of the coronary artery, but the intramural trajectory and the origin from the RPA were established only at surgery. In 3 patients, the technique of side-to-side anastomosis was performed with a good outcome. One patient, who underwent end-to-side anastomosis, died 6 months after the surgery. CONCLUSION: Association with other defects usually occurs in the AOLCARPA, and the intramural aortic trajectory is difficult to clinically diagnose but easy to surgically correct.
  • Intraaortic balloon pump support during coronary angioplasty. Initial experience Original Articles

    Osterne, Evandro C.V.; Alexim, Gustavo A.; Motta, Vicente P. da; Lins, Rosaly M.M.; Carvalho, Eustáquio F.; Carneiro, Marcos V.; Morais, Elio Ribeiro de; Brick, Alexandre V.

    Resumo em Inglês:

    OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction <30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.
  • Laboratory assessment of the hypertensive individual. Value of the main guidelines for high blood pressure Original Articles

    Reis, Rafael S.; Benseñor, Isabela J.; Lotufo, Paulo A.

    Resumo em Inglês:

    OBJECTIVE: To determine if abnormal laboratory findings are more common in individuals with hypertension and in those with other risk factors, such as obesity, smoking and alcohol ingestion. METHODS: A study was carried out in the general outpatient clinics of a university hospital (145 individuals without previous diagnosis of hypertension) and the following variables were assessed: high blood pressure (as defined by the VI Joint National Committee on Prevention, Detection and Treatment of High Blood Pressure - VI JNC), obesity [calculated using body mass index (BMI)], tobacco use, and alcoholic ingestion. The laboratory examinations consisted of the following tests: hemogram, glycemia, uric acid, potassium, total/HDL-fraction cholesterol, triglycerides, calcium and creatinine. RESULTS: High blood pressure was not associated with a higher number of abnormal laboratory tests. Hypertensive individuals with a BMI > or = 25kg/m² or normotensive obese individuals, however, had a higher frequency of diabetes (12X), hypertriglyceridemia (3X), and hypercholesterolemia (2X), as compared with hypertensive individuals with BMI <25kg/m² and preobese/normal weight normotensive individuals. CONCLUSION: High blood pressure is not associated with a higher frequency of abnormal laboratory tests. The association of high blood pressure and obesity, however, increases the detection of diabetes and dyslipidemias.
  • Recurrence of atrial septal defect in three generations Brief Reports

    Ferreira, Celso; Farah, Leila M. S.; Póvoa, Rui M.; Luna Fº, Bráulio; Costa, Andréa; Ferreira Fº, Celso

    Resumo em Inglês:

    Beginning with a patient presenting with an atrial septal defect (ASD) of the secundum type, the genealogy was identified in four affected individuals who belonged to three successive generations of the same family. The defects were visually confirmed in all individuals and were found to be anatomically similar. No other congenital malformations were present in these individuals. The genealogy was identified in 1972, when ASD recurred in two generations, and it was concluded that the mechanism of transmission was autosomal recessive. The fifth individual, identified 21 years later, and having an anomaly identical to that of the others, was the child of a couple who had no consaguinity and whose mother was a member of the previously studied genealogy. Considering the absence of phenotype in the parents and the rarity of the ASD gene in the general population, the occurrence of the uniparental disomy for this family nucleus, and the same autosomal recessive mechanism of transmission by this affected individual is possible. This study reports the familial occurrence of ASD by genetic mechanisms of transmission, emphasizing the necessity for genetic-clinical studies in members of the familial nucleus in order to detect new carriers, who usually are asymptomatic, thereby allowing for early and adequate treatment of individuals who may be affected.
  • Ebstein's anomaly with coarctation of the aorta. An unusual association Brief Reports

    Ebaid, Munir; Azeka, Estela; Ikari, Nana Miura; Sosa, Eduardo A.; Marcial, Miguel Barbero; Atik, Edmar

    Resumo em Inglês:

    Ebstein's anomaly with coarctation of the aorta is an extremely unusual condition. In this report, the clinical and surgical features of 3 male patients, aged 7 months, 4 years and 14 years, are discussed. All patients were in situs solitus. The first 2 patients had atrioventricular and ventriculoarterial discordance and progressed to heart failure in the neonatal period. The third had atrioventricular and ventriculoarterial concordance, as well as Wolf-Parkinson-White syndrome, with frequent episodes of paroxysmal tachycardia. The 3 patients underwent surgery for correction of the coarctation of the aorta. The patient with atrioventricular and ventriculoarterial concordance underwent tricuspid valvuloplasty using a DeVega-like technique. In addition, ablation of 2 anomalous pathways (Kent bundle), which were detected by the electrophysiologic study, was also subsequently performed. The 3 patients showed a good postoperative outcome for 2 years, although, in those with discordance, the surgical procedure did not influence the dysplasia of the tricuspid valve, because this valve showed light to moderate dysfunction.
  • A 63-year-old man with heart failure 3 years after bioprosthetic replacement of mitral and aortic heart valves Clinicopathologic Session

  • The role of depression in coronary artery disease Update

    Manica, André Luiz Langer; Leães, Carolina Garcia Soares; Frey, Benício Noronha; Juruena, Mário Francisco
Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
E-mail: revista@cardiol.br