Acessibilidade / Reportar erro
Radiologia Brasileira, Volume: 42, Número: 4, Publicado: 2009
  • Espectroscopia de prótons e difusão na avaliação dos tumores do sistema musculoesquelético Editoriais

    Aguiar, Rodrigo O. C. de
  • BI-RADS® ultrassonográfico: análise de resultados iniciais Editoriais

    Pereira, Fernanda Philadelpho Arantes
  • Oftalmopatia de Graves, sempre um desafio Editoriais

    Cardoso, Gilberto Perez
  • Qual o seu diagnóstico? Qual É O Seu Diagnóstico?

    Santana Júnior, Pedro José de; Teixeira, Kim-Ir-Sen Santos; Torres, Pedro Paulo Teixeira e Silva; Daher, Renato Tavares; Santana, Patrícia Karla Vilarinho; Aurione, Ana Caroline Vieira
  • Avaliação dosimétrica de uma combinação de aplicadores para braquiterapia de tumores do colo uterino com acometimento da porção distal da vagina Artigos Originais

    Guimarães, Roger Guilherme Rodrigues; Carvalho, Heloisa de Andrade; Stuart, Silvia Radwanski; Rubo, Rodrigo Augusto; Seraide, Rodrigo Migotto

    Resumo em Português:

    OBJETIVO: Avaliar uma alternativa de braquiterapia para tumores do colo uterino acometendo a porção distal da vagina, sem aumentar os riscos de toxicidade. MATERIAIS E MÉTODOS: Estudo teórico comparando três diferentes aplicadores de braquiterapia intracavitária de alta taxa de dose: sonda intrauterina e cilindro vaginal (SC); sonda e anel associado ao cilindro vaginal (SA+C) e um aplicador virtual com sonda, anel e cilindro vaginal em um único conjunto (SAC). Foram prescritas doses de 7 Gy no ponto A e 5 Gy na superfície ou a 5 mm de profundidade na mucosa vaginal, mantendo as doses nos pontos de reto, bexiga e sigmoide abaixo dos limites de tolerância. Foram comparados os volumes englobados pelas isodoses de 50% (V50), 100% (V100), 150% (V150) e 200% (V200), respectivamente. RESULTADOS: Tanto SA+C quanto SAC apresentaram melhor distribuição de dose quando comparados ao aplicador SC. A distribuição de dose obtida com SA+C foi semelhante à do aplicador SAC, sendo V150 e V200 cerca de 50% maiores para SA+C, todavia, dentro do cilindro. CONCLUSÃO: A utilização de SA+C em uma única aplicação em dois tempos pode ser uma alternativa de tratamento para pacientes que apresentam tumores de colo uterino com acometimento distal da vagina.

    Resumo em Inglês:

    OBJECTIVE: To evaluate an alternative brachytherapy technique for uterine cervix cancer involving the distal vagina, without increasing the risk of toxicity. MATERIALS AND METHODS: Theoretical study comparing three different high-dose rate intracavitary brachytherapy applicators: intrauterine tandem and vaginal cylinder (TC); tandem/ring applicator combined with vaginal cylinder (TR+C); and a virtual applicator combining both the tandem/ring and vaginal cylinder in a single device (TRC). Prescribed doses were 7 Gy at point A, and 5 Gy on the surface or at a 5 mm depth of the vaginal mucosa. Doses delivered to the rectum, bladder and sigmoid colon were kept below the tolerance limits. Volumes covered by the isodoses, respectively, 50% (V50), 100% (V100), 150% (V150) and 200% (V200) were compared. RESULTS: Both the combined TR+C and TRC presented a better dose distribution as compared with the TC applicator. The TR+C dose distribution was similar to the TRC dose, with V150 and V200 being about 50% higher for TR+C (within the cylinder). CONCLUSION: Combined TR+C in a two-time single application may represent an alternative therapy technique for patients affected by uterine cervix cancer involving the distal vagina.
  • Espectroscopia de prótons e perfusão por ressonância magnética na avaliação dos tumores do sistema musculoesquelético Artigos Originais

    Costa, Flávia Martins; Vianna, Evandro Miguelote; Domingues, Rômulo Côrtes; Setti, Marcela; Meohas, Walter; Rezende, José Francisco; Domingues, Romeu Côrtes; Gasparetto, Emerson Leandro

    Resumo em Português:

    OBJETIVO: Avaliar a espectroscopia de prótons e o estudo dinâmico do contraste por ressonância magnética na diferenciação dos tumores musculoesqueléticos benignos e malignos. MATERIAIS E MÉTODOS: Foram estudados 55 pacientes com tumores musculoesqueléticos (27 malignos e 28 benignos). Os exames foram realizados em aparelho de ressonância magnética de 1.5 T com protocolo convencional e espectroscopia de prótons com TE de 135 ms. O estudo dinâmico do contraste foi adquirido pela sequência T1 gradiente-eco após a administração intravenosa de gadolínio. Curvas de intensidade de sinal versus tempo e valores de slope foram calculados. A análise estatística foi realizada pelo teste de Levene, seguido pelo teste t de Student, além dos testes qui-quadrado de Pearson e exato de Fischer. RESULTADOS: A sensibilidade, especificidade e acurácia da espectroscopia de prótons foram, respectivamente, de 87,5%, 92,3% e 90,9% (p < 0,0001). Além disso, houve significativa diferença entre o valor quantitativo da curva entre as lesões benignas (média de 27,5% por minuto) e malignas (média de 110,9% por minuto) (p < 0,0001). CONCLUSÃO: Os estudos quantitativo e qualitativo da análise dinâmica do contraste por ressonância magnética associados à presença do pico de colina são úteis na diferenciação dos tumores musculoesqueléticos em benignos e malignos.

    Resumo em Inglês:

    OBJECTIVE: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. MATERIALS AND METHODS: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 135 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Timesignal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. RESULTS: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p < 0.0001). Statistically significant difference was observed in the slope (%/min) between benign (mean, 27.5%/min) and malignant (mean, 110.9%/min) lesions (p < 0.0001). CONCLUSION: The time-intensity curve and slope values using dynamic-enhanced perfusion magnetic resonance imaging in association with the presence of choline peak demonstrated by single voxel magnetic resonance spectroscopy study are useful in the differentiation between malignant and benign musculoskeletal tumors.
  • Alcoolização percutânea de cistos renais: revisão da literatura e apresentação de resultados Artigos Originais

    D'Ippolito, Giuseppe; Torres, Lucas Rios; Ribeiro, Alessandra Caivano Rodrigues; Roque, Arcílio de Jesus; Ortiz, Valdemar; Ajzen, Sergio

    Resumo em Português:

    OBJETIVO: Demonstrar a eficácia e os resultados práticos da alcoolização percutânea de pacientes com cistos renais simples sintomáticos. MATERIAIS E MÉTODOS: Foram revistos os resultados obtidos em dez pacientes com cistos renais simples sintomáticos (oito homens e duas mulheres), com idade entre 28 e 72 anos (média de 55 anos), submetidos a pelo menos duas alcoolizações percutâneas. A indicação do procedimento foi dor no flanco refratária nos dez pacientes, sete deles com algum grau de hidronefrose pela localização parapiélica do cisto. O volume aspirado variou entre 20 e 1.300 ml (média de 200 ml). O tempo médio de seguimento após o procedimento foi de sete meses. O procedimento foi dirigido por ultrassonografia em dois casos e por tomografia computadorizada em oito. O tempo de internação variou entre 24 e 72 horas. Foi considerado sucesso completo do tratamento o desaparecimento do cisto, e parcial a redução maior que 50%. RESULTADOS: Durante o seguimento houve redução completa do cisto em sete pacientes e redução parcial em três. Em nenhum caso foram registradas complicações e os pacientes toleraram bem o procedimento. CONCLUSÃO: A alcoolização percutânea de cistos renais sintomáticos é um procedimento seguro, efetivo e pouco invasivo e com resultados semelhantes aos obtidos por outros autores.

    Resumo em Inglês:

    OBJECTIVE: To demonstrate the effectiveness and practical outcomes of percutaneous ethanol sclerotherapy in patients with symptomatic simple renal cysts. MATERIALS AND METHODS: The authors reviewed the outcomes of ten patients (eight men and two women) in the age range between 28 and 72 years (mean, 55 years) submitted to at least two procedures of percutaneous sclerotherapy for symptomatic simple renal cysts. Main presentation was refractory flank pain in all patients, seven of them with some degree of hydronephrosis because of the parapyelic localization of the cyst. The aspirated volume ranged from 20 to 1300 ml (mean, 200 ml). The mean follow-up period following the procedure was of seven months. Two patients had ultrasoud-guided sclerotherapy, and eight, computed tomography-guided sclerotherapy. The hospital stay period ranged between 24 and 72 hours. Complete success corresponded to total cyst regression, and partial success corresponded to recurrence of less than half the original cyst volume. RESULTS: Complete cyst ablation was achieved in seven patients and partial resolution in three. No complication was observed and the therapy was well tolerated by all of the patients. CONCLUSION: Percutaneous ethanol sclerotherapy of symptomatic simple renal cysts is a safe, effective and minimally invasive procedure, with results similar to the ones reported by other studies.
  • Quantificação volumétrica da hiperplasia neointimal em artérias ilíacas após implante de suporte intravascular metálico Artigos Originais

    Moreira, Samuel Martins; Kambara, Antonio Massamitsu; Ajzen, Sergio; Costa Junior, José de Ribamar

    Resumo em Português:

    OBJETIVO: Quantificar a hiperplasia neointimal em artérias ilíacas após stent, correlacionando fatores clínicos, arteriais e materiais dos stents. MATERIAIS E MÉTODOS: De junho de 2003 a agosto de 2005, 60 pacientes realizaram angioplastia transluminal percutânea e stent. Desses, 30 foram reestudados com ultrassonografia intravascular. Os dados foram analisados no laboratório de análise quantitativa. RESULTA-DOS: Dezesseis pacientes eram do sexo masculino (53,3%) e 14 (46,7%), do sexo feminino. A média de idade foi de 60,3 anos. Apresentaram hipertensão arterial 22 pacientes (73,3%), tabagismo, 18 (62,1%), hiperlipidemia, 20 (66,7%), e diabetes, 9 (30%). Foram implantados 20 stents de nitinol (66,7%) e 10 de aço inoxidável (33,3%). Quatro pacientes eram TASC A (13,3%), 15 eram TASC B (50%) e 11, TASC C (36,7%). O volume da hiperplasia variou de 49,02 mm³ a 112,87 mm³ (média de 80,33 mm³). O percentual de obstrução intra-stent variou de 18% a 47% (média de 27,4%). Os resultados clínicos obtidos com stent se mantiveram até o reestudo. CONCLUSÃO: A hiperplasia neointimal sempre ocorre após a angioplastia transluminal percutânea e stent, porém os percentuais de obstrução não foram superiores a 50% em nenhum caso. Não houve diferença estatisticamente significante dos percentuais de obstrução intra-stent quanto aos materiais dos stents, aos fatores clínicos e aos fatores arteriais.

    Resumo em Inglês:

    OBJECTIVE: To quantify neointimal hyperplasia in iliac arteries after stent implantation, correlating clinical, arterial factors and stent material. MATERIALS AND METHODS: In the period from June/2003 to August/ 2005, 60 patients were submitted to percutaneous transluminal angioplasty and stenting. Among these patients, 30 were followed-up with intravascular ultrasonography. Data were analyzed in a laboratory of quantitative analysis by means of a specific software. RESULTS: Sixteen (53.3%) patients were men, and 14 (46.7%), women, and the mean age was 60.3 years. Arterial hypertension was observed in 22 patients (73.3%), smoking in 18 (62.1%), hyperlipidemia in 20 (66.7%), and diabetes in 9 (30%). A total of 20 nitinol stents (66.7%) and 10 stainless steel stents (33.3%) were implanted. Four patients were classified as TASC A (13.3%), 15 TASC B (50%) and 11 TASC C (36.7%). The neointimal hyperplasia volume ranged from 49.02 mm³ to 112.87 mm³ (mean, 80.33 mm³). The rate of intrastent obstruction ranged from 18% to 47% (mean, 27.4%). The clinical outcomes achieved with stenting were sustained through the follow-up. CONCLUSION: Neointimal hyperplasia is a common finding after percutaneous transluminal angioplasty and stenting, but in the present study the stenosis rate was never higher than 50%. There was no statistically significant difference in intrastent stenosis rates in relation to stents materials, clinical and arterial risk factors.
  • Acurácia dos achados ultrassonográficos do câncer de mama: correlação da classificação BI-RADS® e achados histológicos Artigos Originais

    Nascimento, José Hermes Ribas do; Silva, Vinicius Duval da; Maciel, Antonio Carlos

    Resumo em Português:

    OBJETIVO: O objetivo geral do estudo é avaliar a acurácia da ultrassonografia (BI-RADS) no diagnóstico do câncer de mama, e os objetivos específicos, descrever a frequência de apresentação dos diferentes achados ultrassonográficos e a avaliação da concordância entre observadores. MATERIAIS E MÉTODOS: Exames de 110 pacientes encaminhados para biópsia, com diagnóstico prévio de nódulos, foram reanalisados independentemente por dois médicos especialistas utilizando a nomenclatura do BI-RADS. Os achados histológicos foram utilizados como padrão-ouro. A acurácia dos achados foi determinada. As diferenças nos grupos de comparação foram analisadas com teste qui-quadrado para variáveis categóricas e a concordância entre os médicos foi calculada por meio da estatística kappa (κ). RESULTADOS: Cento e dez massas mamárias foram avaliadas pelo ultrassom, sendo que 76 (69%) foram benignas e 34 (30,9%), malignas. Foram observados, entre os radiologistas, sensibilidade variando entre 70,5% e 82,3%, valor preditivo negativo entre 81,1% e 87,5%, valor preditivo positivo entre 42,1% e 45,1%, especificidade entre 56,58% e 55,2% e acurácia entre 60,9% e 63,6%. Na avaliação entre observadores foi obtida concordância global considerada moderada (κ= 0,50). CONCLUSÃO: O BI-RADS 4ª edição é um acurado sistema para auxiliar os médicos na descrição das lesões mamárias e na tomada de condutas.

    Resumo em Inglês:

    OBJECTIVE: The main purpose of the present study is to evaluate the accuracy of ultrasonography (BI-RADS) in the diagnosis of breast cancer whereas the additional specific objectives are to describe the frequency of different sonographic findings and evaluating interobserver agreement. MATERIALS AND METHODS: Images of 110 patients who had been referred for biopsy with previous diagnosis of breast nodules were independently reviewed by two specialists according to the BI-RADS classification. Histological findings were utilized as a gold-standard. The accuracy of findings was determined. The chi-squared test for categorical variables was utilized in the analysis of the differences resulting from the groups comparison, and the interobserver agreement was calculated with kappa () statistics. RESULTS: Among 110 breast masses evaluated by ultrasonography, 76 (69%) were benign and 34 (30.9%) were malignant. According to the radiologists, the sensitivity ranged from 70.5% to 82.3%, negative predictive value, from 81.1% to 87.5%, positive predictive value, from 42.1% to 45.1%, specificity from 56.58% to 55.2%, and accuracy from 60.9% to 63.6%. The global interobserver agreement was considered as moderate ( = 0.50). CONCLUSION: The fourth edition of BI-RADS provides radiologists with an accurate clinical decision support system for the diagnosis and management of breast disease.
  • Utilização do índice de resistência vascular na diferenciação entre nódulos mamários benignos e malignos Artigos Originais

    Schmillevitch, Joel; Guimarães Filho, Hélio Antonio; De Nicola, Harley; Gorski, Ana Cheila

    Resumo em Português:

    OBJETIVO: O objetivo deste estudo foi avaliar o significado do Doppler espectral por meio da obtenção do índice de resistência vascular na diferenciação entre lesões mamárias benignas e malignas. MATERIAIS E MÉTODOS: Dezenove lesões malignas e 18 benignas, diagnosticadas por estudo histológico, foram submetidas previamente a análise de sua vascularização por meio do Doppler espectral para se obter o índice de resistência vascular. RESULTADOS: Observou-se diferença estatisticamente significante (p < 0,001) entre os valores médios do índice de resistência para os resultados benigno e maligno (0,62x 0,80, respectivamente), em nódulos maiores que 1 cm. Um índice de resistência 0,69 foi altamente associado a lesões malignas, com sensibilidade de 84,2%, especificidade de 88,9%, taxa de falso-positivo de 11,1% e taxa de falso-negativo de 15,8%. CONCLUSÃO: A análise do índice de resistência vascular pode fornecer grande auxílio na avaliação das lesões nodulares da mama maiores que 1 cm, em conjunto com as informações obtidas por meio da escala de cinzas, com elevada sensibilidade e especificidade.

    Resumo em Inglês:

    OBJECTIVE: The present study was aimed at evaluating the role played by spectral Doppler as a method to measure the vascular resistance index in the differentiation between benign and malignant breast lesions. MATERIALS AND METHODS: Nineteen malignant and 18 benign lesions histologically diagnosed had their vascularization previously analyzed through the resistance index. RESULTS: A statistically significant difference (p < 0.001) was observed between the mean values of resistance index for benign and malignant lesions (respectively 0.62x 0.80) in nodular breast lesions greater than 1 cm. A resistance index 0.69 was highly associated with malignant lesions, with 84.2% sensitivity, 88.9% specificity, false-positive rate of 11.1%, and false-negative rate of 15.8%. CONCLUSION: The analysis of vascular resistance index combined with findings on grayscale sonographic images can be of great assistance in the assessment of nodular breast lesions greater than 1 cm, with high sensitivity and specificity.
  • Refluxo gastroesofágico: estudo comparativo da receptividade e sensibilidade entre seriografia e ultrassonografia Artigos Originais

    Sakate, Makoto; Silveira, Guilherme Lopes; Muzio, Bruno Paulino de; Teigao Junior, Hudson; Ozaki, Jorge Guilherme Okanobo; Spadim, Marcelo Dimas; Dantas, Roberto Cesar Teixeira; Machado, Nilton Carlos

    Resumo em Português:

    OBJETIVO: Estudo comparativo da receptividade (colaboração) e sensibilidade da seriografia do esôfago, estômago e duodeno em relação à ultrassonografia do esôfago intra-abdominal em pacientes com suspeita de refluxo gastroesofágico. MATERIAIS E MÉTODOS: Foram incluídos no estudo 42 pacientes pediátricos (26 masculinos, com idade média de 33,64 ± 34,33 meses, e 16 femininos, com idade média de 31,02 ± 35,56 meses) com suspeita de refluxo gastroesofágico, os quais foram submetidos, inicialmente, a seriografia do esôfago, estômago e duodeno, e posteriormente, a ultrassonografia do esôfago intra-abdominal. RESUL-TADOS: A análise estatística comparativa entre os sexos e as idades sugere não haver evidência de associação com a colaboração, tanto para a seriografia do esôfago, estômago e duodeno como para a ultrassonografia do esôfago intra-abdominal. Entretanto, na classificação quanto ao tipo de colaboração, a técnica de seriografia do esôfago, estômago e duodeno apresentou menos de 50% de colaboração, enquanto 80,49% dos pacientes colaboraram com a ultrassonografia do esôfago intra-abdominal. Quanto à sensibilidade do diagnóstico de refluxo gastroesofágico, a técnica de ultrassonografia do esôfago intra-abdominal (85,7%) foi significativamente superior à de seriografia do esôfago, estômago e duodeno (47,6%). CONCLUSÃO: O presente estudo sugere que se proceda a ultrassonografia do esôfago intra-abdominal, mesmo na ausência de refluxo gastroesofágico na seriografia do esôfago, estômago e duodeno.

    Resumo em Inglês:

    OBJECTIVE: Comparative study of receptiveness (cooperation) and sensitivity of upper gastrointestinal series and intraabdominal esophagus ultrasonography in patients with suspicion of gastroesophageal reflux. MATERIALS AND METHODS: The present study included 42 pediatric patients (26 male, with mean age of 33.64 ± 34.33 months, and 16 female, with mean age of 31.02 ± 35.56 months) with suspicion of gastroesophageal reflux, who were initially submitted to upper gastrointestinal series and subsequently to intraabdominal esophagus ultrasonography. RESULTS: The statistical comparative analysis covering sexes and ages suggests no evidence of association with cooperation, both for the upper gastrointestinal series and the intraabdominal esophagus ultrasonography. However, in the classification of the patients' cooperation, the technique of upper gastrointestinal series presented less than 50% of cooperation, while 80.49% of patients cooperated in the intraabdominal esophagus ultrasonography examinations. As regards the methods sensitivity for the diagnosis of gastroesophageal reflux, the technique of intraabdominal esophagus ultrasonography was significantly superior (85.7%) to the upper gastrointestinal series (47.6%). CONCLUSION: The present study suggests that an intraabdominal esophagus ultrasonography should be performed even if gastroesophageal reflux even if it is not detected at the upper gastrointestinal series.
  • Simulação computacional de um feixe de fótons de 6 MV em diferentes meios heterogêneos utilizando o código PENELOPE Artigos Originais

    Salata, Camila; Sibata, Claudio Hissao; Ferreira, Nadya Maria; Almeida, Carlos Eduardo de

    Resumo em Português:

    OBJETIVO: Utilizar o código PENELOPE e desenvolver geometrias onde estão presentes heterogeneidades para simular o comportamento do feixe de fótons nessas condições. MATERIAIS E MÉTODOS: Foram feitas simulações do comportamento da radiação ionizante para o caso homogêneo, apenas água, e para os casos heterogêneos, com diferentes materiais. Consideraram-se geometrias cúbicas para os fantomas e geometrias em forma de paralelepípedos para as heterogeneidades com a seguinte composição: tecido simulador de osso e pulmão, seguindo recomendações da International Commission on Radiological Protection, e titânio, alumínio e prata. Definiram-se, como parâmetros de entrada: a energia e o tipo de partícula da fonte, 6 MV de fótons; a distância fonte-superfície de 100 cm; e o campo de radiação de 10x 10 cm². RESULTADOS: Obtiveram-se curvas de percentual de dose em profundidade para todos os casos. Observou-se que em materiais com densidade eletrônica alta, como a prata, a dose absorvida é maior em relação à dose absorvida no fantoma homogêneo, enquanto no tecido simulador de pulmão a dose é menor. CONCLUSÃO: Os resultados obtidos demonstram a importância de se considerar heterogeneidades nos algoritmos dos sistemas de planejamento usados no cálculo da distribuição de dose nos pacientes, evitando-se sub ou superdosagem dos tecidos próximos às heterogeneidades.

    Resumo em Inglês:

    OBJECTIVE: The PENELOPE code was utilized to simulate irradiation geometries where heterogeneities are present and to simulate a photon beam behavior under these conditions. MATERIALS AND METHODS: For the homogeneous case, the ionizing radiation behavior was simulated only with water, and different materials were introduced to simulate heterogeneous conditions. Cubic geometries were utilized for the homogeneous phantoms, and parallelepiped-shaped geometries for the heterogeneities with the following composition: bone and lung tissue simulators, as recommended by the International Commission on Radiological Protection, and titanium, aluminum and silver. Input parameters were defined as follows: energy and type of source, 6 MV photons; source-surface distance=100 cm; and radiation field of 10x 10 cm². RESULTS: Percentage depth-dose curves were obtained for all the cases. As result, it was observed that for high electronic density materials, such as silver, the absorbed dose is higher than the absorbed dose in the homogeneous phantom, and for the lung tissue simulator, it is lower. CONCLUSION: Results clearly demonstrate the relevant role of heterogeneities in the treatment planning system algorithms utilized in the calculation of dose distribution in patients, increasing the accuracy of the dose delivered to the tumor and avoiding unnecessary irradiation of healthy tissues.
  • Teste de proficiência para medições de radioatividade na medicina nuclear Artigos Originais

    Iwahara, Akira; Tauhata, Luiz; Oliveira, Antonio Eduardo de; Nícoli, Ieda Gomes; Alabarse, Frederico Gil; Xavier, Ana Maria

    Resumo em Português:

    OBJETIVO: Avaliar o desempenho dos calibradores de radionuclídeos de 55 serviços de medicina nuclear brasileiros em medição de atividade de radiofármaco contendo 99Tc m. Testes de proficiência foram aplicados em 63 resultados originados do programa de comparação promovido pelo Laboratório Nacional de Metrologia das Radiações Ionizantes do Instituto de Radioproteção e Dosimetria. MATERIAIS E MÉTODOS: O desempenho foi avaliado em relação ao critério de aceitação de ±10% de exatidão exigido pela norma brasileira e também aos critérios estabelecidos pela ISO/IEC Guide 43-1, e classificado como "aceitável" ou "não aceitável". Amostras de 99Tc m usadas nas comparações foram fornecidas por alguns dos participantes e calibradas no Laboratório Nacional de Metrologia das Radiações Ionizantes para determinar o valor de referência da atividade. RESULTADOS: Esta comparação com o 99Tc m mostrou que o desempenho aceitável atendendo à exigência da norma regulatória foi de 82,5%, enquanto pelos critérios estabelecidos pela norma ISO/IEC 43-1 foi de 81,0%. Por outro lado, calibradores de radionuclídeos com detector Geiger-Müller apresentaram desempenho inferior quando comparados com os dotados com câmara de ionização. CONCLU-SÃO: Nesta comparação, a avaliação do desempenho baseada nos critérios da ISO/IEC 43-1, os quais são aplicados a laboratórios analíticos, apesar de serem mais restritivas, foi bastante consistente com o critério de exatidão exigido pela norma nacional.

    Resumo em Inglês:

    OBJECTIVE: To assess the performance of radionuclide calibrators in 55 Brazilian nuclear medicine services in the measurement of 99Tc m radiopharmaceutical activity. Proficiency tests were applied to data sets with 63 results originated from the comparison program developed by Laboratório Nacional de Metrologia das Radiações Ionizantes of Instituto de Radioproteção e Dosimetria. MATERIALS AND METHODS: The calibrators' performance was evaluated in compliance with the acceptance criterion of ±10% accuracy required by the Brazilian standards and also the criteria established by the ISO/IEC Guide 43-1, and classified as either "acceptable" or "non-acceptable". The samples of 99Tc m utilized in the comparison were supplied by some of the participants and calibrated at Laboratório Nacional de Metrologia das Radiações Ionizantes for determining the activity reference value. RESULTS: The present study utilizing 99Tc m has shown that 82.5% of the calibrators were considered as acceptable according to the Brazilian standards, while by the criteria established by ISO/IEC 43-1, 81.0% were considered as acceptable. On the other hand, radionuclide calibrators with Geiger-Müller detectors presented unsatisfactory performance when compared with calibrators with ionization chambers. CONCLUSION: The performance evaluation based on the ISO/IEC 43-1 criteria, which are applied to analytical laboratories, in spite of being more restrictive, has demonstrated to be quite consistent with the accuracy criterion established by the Brazilian standard.
  • Oftalmopatia tireoidea revisitada Artigo De Revisão

    Machado, Karina Freitas Soares; Garcia, Marcelo de Mattos

    Resumo em Português:

    A oftalmopatia tireoidea é doença orbitária autoimune intimamente associada com o hipertireoidismo, porém podendo existir separadamente. Pode preceder, coincidir ou suceder o início da disfunção tireoidea, raramente ocorrendo em eutireoideos ou hipotireoideos. Os músculos extraoculares são os principais alvos acometidos e tornam-se aumentados de volume, determinando oftalmoplegia e proptose. Outros sinais importantes incluem retração palpebral, hiperemia conjuntival e edema periorbitário. Perda visual pode ocorrer se há compressão do nervo óptico no ápice orbitário. A oftalmopatia tireoidea é caracterizada por inflamação, congestão, hipertrofia e fibrose da gordura e músculos orbitários. A atividade da doença é dividida em fase aguda ou inflamatória, seguida pela fase inativa associada com alterações fibróticas e infiltração gordurosa. O diagnóstico é clínico, e quando este é difícil ou se suspeita de neuropatia óptica os métodos de imagem são indicados. A tomografia computadorizada e a ressonância magnética podem confirmar o diagnóstico e avaliar a área crítica do ápice orbitário. A ressonância magnética é superior, em virtude da resolução tecidual e da sua capacidade de avaliar a atividade da doença (mediante sequências com TR longo) e detectar alterações inflamatórias, auxiliando o planejamento terapêutico no momento certo, melhorando o prognóstico.

    Resumo em Inglês:

    Thyroid ophthalmopathy is an autoimmune orbital disorder closely associated with Graves' disease, although both conditions may also occur isolatedly. Thyroid ophthalmopathy may precede, coincide or follow the thyroid dysfunction onset and may rarely occur in euthyroid and hypothyroid patients. The extraocular muscles are most frequently involved and become enlarged resulting in ophthalmoplegia and proptosis. Other relevant signs include palpebral retraction, conjuctival hyperemia and periorbitary edema. Visual loss may occur in association with compressive optic neuropathy at the orbital apex. Thyroid ophthalmopathy is characterized by inflammation, congestion, hypertrophy and fibrosis involving fat and the orbital muscles. The disease activity is divided into two phases: an acute or inflammatory phase and a second one corresponding to an inactive phase associated with fibrotic changes and fat infiltration of the retrobulbar tissues. The diagnosis is based on clinical findings and imaging methods are indicated in case of doubt or suspicion of optic neuropathy. Computed tomography and magnetic resonance imaging can confirm the diagnosis, allowing the evaluation of the critical region of the orbital apex. Magnetic resonance imaging is the method of choice considering the superior tissue contrast resolution, besides the capacity of evaluating the disease activity by means of long TR sequences and detecting inflammatory changes, with a relevant role in a timely therapeutic planning, which may improve the prognosis.
  • Doença de Erdheim-Chester: relato de dois casos Relatos De Casos

    Hexsel, Fernando Fernandez; Canazaro, Letícia Frigo; Capoani, Mariana; Aguiar, Paula Musa; Suwa, Eiji; Maciel, Antonio Carlos

    Resumo em Português:

    A doença de Erdheim-Chester é uma rara histiocitose de células não-Langerhans, de etiologia desconhecida, que apresenta manifestações sistêmicas, atingindo ossos, sistema nervoso central, olhos, pulmões, mediastino, rins e retroperitônio. Relatamos dois casos que cursaram com a apresentação típica da doença. Os achados radiológicos foram concordantes com a literatura e orientaram a suspeita diagnóstica, confirmada pelo exame imuno-histoquímico.

    Resumo em Inglês:

    Erdheim-Chester disease is a rare non-Langerhans cell histiocytosis of unknown etiology, affecting multiple organ system, involving bones, central nervous system, eyes, lungs, mediastinum, kidneys and retroperitoneum. The authors report two cases that progressed with the typical presentation of the disease. Radiological findings were in agreement with literature and guided the diagnosis, confirmed by immunohistochemistry.
  • Hemangioma cavernoso hepático roto: relato de caso e revisão da literatura Relatos De Casos

    Paula Neto, Walter Teixeira de; Koifman, Ana Celia Baptista; Martins, Carlos Alberto de Souza

    Resumo em Português:

    O hemangioma hepático é frequentemente assintomático e, mesmo quando de grandes dimensões, não mostra tendência a sangramento. Os autores relatam o caso de uma paciente de 31 anos de idade com dor abdominal aguda, cujos exames de imagem evidenciaram hematoma no lobo hepático esquerdo, associado a hemoperitônio. A paciente foi submetida a hepatectomia esquerda, com o diagnóstico histopatológico de hemangioma cavernoso.

    Resumo em Inglês:

    Hepatic hemangioma is frequently asymptomatic, and bleeding is rare, even in cases of large lesions. The authors report the case of a 31-year-old female patient presenting with acute abdominal pain, whose imaging studies have demonstrated hematoma in the left hepatic lobe associated with hemoperitoneum. The patient was submitted to left hepatectomy, with a final histopathological diagnosis of cavernous hemangioma.
  • Alterações neurorradiológicas em pacientes com síndrome de Kallmann: estudos por ressonância magnética Resumos De Teses

    Santos, Marcel Koenigkam
  • Síndrome de Rett: achados clínicos, genéticos e por ressonância magnética Resumos De Teses

    Farage, Luciano
  • Avaliação de pacientes com hepatopatias crônicas através de ressonância magnética de 3 tesla Resumos De Teses

    Zapparoli, Maurício
  • Avaliação videofluoroscópica da dinâmica da deglutição e dos processos disfágicos Resumos De Teses

    Koch, Tiago Vieira
  • Determinação dos valores do tamanho do fígado de crianças normais, entre 0 e 7 anos de idade, por ultrassonografia Resumos De Teses

    Rocha, Silvia Maria Sucena da
  • Estudo comparativo entre artrotomografia computadorizada "multislice" e artrorressonância magnética na instabilidade do ombro correlacionadas com os achados artroscópicos Resumos De Teses

    Gomez, Gisele Florence Carvalheira de Azevedo
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem Av. Paulista, 37 - 7º andar - conjunto 71, 01311-902 - São Paulo - SP, Tel.: +55 11 3372-4541, Fax: 3285-1690, Fax: +55 11 3285-1690 - São Paulo - SP - Brazil
E-mail: radiologiabrasileira@cbr.org.br