Acessibilidade / Reportar erro
Brazilian Dental Journal, Volume: 31, Número: 4, Publicado: 2020
  • Effect of Occlusal Adjustment on Postoperative Pain after Root Canal Treatment: A Randomized Clinical Trial Article

    Vianna, Elizângela Cristina Barbosa; Herkrath, Fernando José; Martins, Izabelly Esteves Bittencourt; Lopes, Luana Pontes Barros; Marques, André Augusto Franco; Sponchiado Júnior, Emílio Carlos

    Resumo em Português:

    Resumo O objetivo deste estudo prospectivo, randomizado e clínico foi analisar a influência do ajuste oclusal na prevalência de dor pós-operatória após o tratamento endodôntico. Setenta e oito pacientes, diagnosticados com pulpite irreversível sintomática com indicação de tratamento endodôntico, foram selecionados para participar do estudo. Os participantes foram randomizados e divididos em dois grupos: no grupo de ajuste oclusal (GAO), foi realizado tratamento endodôntico com posterior ajuste oclusal. No grupo controle (GC), o tratamento endodôntico foi realizado sem ajuste oclusal. Os tratamentos foram realizados pelo mesmo operador. A ocorrência e a intensidade da dor foram registradas em duas escalas: a escala de classificação verbal (VRS) e a escala de classificação numérica (NRS). A avaliação da dor foi realizada por um segundo examinador, cego para o experimento, 6, 24 e 72 horas após o tratamento endodôntico. Os dados foram analisados utilizando testes de Mann-Whitney, qui-quadrado e exato de Fisher. No grupo de ajuste oclusal, 71,1% relataram dor pós-operatória e 67,5% relataram dor no grupo controle. Na avaliação de 6 horas, 21 indivíduos relataram dor no grupo de ajuste oclusal e 24 no grupo controle (p=0,672). Na avaliação de 24 horas, 18 e 19 indivíduos relataram dor (p=0,991) e, na avaliação de 72 horas, 8 e 4 relataram dor (p=0,219), respectivamente. O ajuste oclusal não influenciou a prevalência de dor pós-operatória após o tratamento endodôntico em dentes com pulpite irreversível sintomática.

    Resumo em Inglês:

    Abstract The aim of this prospective, randomized, clinical study was to analyze the influence of occlusal adjustment on the prevalence of postoperative pain after endodontic treatment. Seventy-eight patients, diagnosed with symptomatic irreversible pulpitis with indication for endodontic treatment, were selected to participate in the study. The participants were randomized and divided into two groups: in the occlusal adjustment group (OAG), endodontic treatment was performed with subsequent occlusal adjustment. In the control group (CG), endodontic treatment was performed without occlusal adjustment. Treatments were performed by the same operator. Pain occurrence and intensity were recorded on two scales: the verbal rating scale (VRS) and numerical rating scale (NRS). Pain assessment was carried out by a second examiner, blinded to the experiment, 6, 24 and 72 h after endodontic treatment. Data were analyzed using Mann-Whitney, chi-squared, and Fisher’s exact tests. In the occlusal adjustment group, 71.1% reported postoperative pain and 67.5% reported pain in the control group. At the 6-hour assessment, 21 individuals reported pain in the occlusal adjustment group and 24 in the control group (p=0.672). At the 24-hour assessment, 18 and 19 individuals reported pain (p=0.991) and at the 72-hour assessment, 8 and 4 reported pain (p=0.219), respectively. Occlusal adjustment did not influence the prevalence of postoperative pain of endodontically treated teeth with symptomatic irreversible pulpitis.
  • Model for Predicting Temporomandibular Dysfunction: Use of Classification Tree Analysis Article

    Waked, Jorge P; Canuto, Mariana P. L. de A. M.; Gueiros, Maria Cecilia S. N.; Aroucha, João Marcílio C. N. L.; Farias, Cleysiane G.; Caldas Jr, Arnaldo de F.

    Resumo em Português:

    Resumo O objetivo deste estudo foi construir um modelo preditivo que utiliza a análise estatística de árvore de classificação para predizer a ocorrência de disfunção temporomandibular, dividindo a amostra em grupos de alto e baixo risco para o desenvolvimento da doença. A utilização de abordagens estatísticas preditivas que facilitem o processo de reconhecimento e / ou previsão da ocorrência de disfunção temporomandibular é de interesse da comunidade científica, com o objetivo de fornecer aos pacientes soluções mais adequadas a cada caso. Trata-se de um estudo transversal analítico de base populacional que envolveu uma amostra de 776 indivíduos que procuraram atendimento médico ou odontológico nas Unidades de Saúde da Família de Recife, PE, Brasil. A amostra foi submetida à anamnese por meio do instrumento Research Diagnostic Criteria for Temporomandibular Disorders. Os dados foram inseridos no software Statistical Package for the Social Sciences 20.0 e analisados pelo teste Qui-quadrado de Pearson para análise bivariada e pelo método de árvore de classificação para análise multivariada. A desordem temporomandibular pode ser prevista pela presença da dor orofacial, idade e depressão. O grupo de alto risco foi composto por indivíduos com dor orofacial, entre 25 e 59 anos e que apresentavam depressão. O grupo de baixo risco foi composto por indivíduos sem dor orofacial. Os autores puderam concluir que o melhor preditor para a disfunção temporomandibular foi a dor orofacial e que o modelo preditivo proposto pela árvore de classificação pode ser aplicado como ferramenta para simplificar a tomada de decisão em relação à ocorrência de disfunção temporomandibular.

    Resumo em Inglês:

    Abstract The aim of this study was to construct a predictive model that uses classification tree statistical analysis to predict the occurrence of temporomandibular disorder, by dividing the sample into groups of high and low risk for the development of the disease. The use of predictive statistical approaches that facilitate the process of recognizing and/or predicting the occurrence of temporomandibular disorder is of interest to the scientific community, for the purpose of providing patients with more adequate solutions in each case. This was a cross-sectional analytical population-based study that involved a sample of 776 individuals who had sought medical or dental attendance at the Family Health Units in Recife, PE, Brazil. The sample was submitted to anamnesis using the instrument Research Diagnostic Criteria for Temporomandibular Disorders. The data were inserted into the software Statistical Package for the Social Sciences 20.0 and analyzed by the Pearson Chi-square test for bivariate analysis, and by the classification tree method for the multivariate analysis. Temporomandibular disorder could be predicted by orofacial pain, age and depression. The high-risk group was composed of individuals with orofacial pain, those between the ages of 25 and 59 years and those who presented depression. The low risk group was composed of individuals without orofacial pain. The authors were able to conclude that the best predictor for temporomandibular disorder was orofacial pain, and that the predictive model proposed by the classification tree could be applied as a tool for simplifying decision making relative to the occurrence of temporomandibular disorder.
  • Comparative Clinical Study Using Short and Conventional Implants in Bilateral Jaw Posteriors Article

    Pereira, Carlos Henrique Sardenberg; Pereira, Anna Carolina Britto de Macedo Sardenberg; Francischone, Carlos Eduardo

    Resumo em Português:

    Resumo O objetivo deste estudo foi comparar clínica e radiograficamente implantes extra curtos e padrões. Quarenta e dois implantes foram instalados em 10 pacientes selecionados. Eles receberam carga protética somente após o tempo de espera convencional para a osseointegração e as próteses foram feitas ferulizadas. As imagens radiográficas foram realizadas para avaliar as perdas ósseas verticais e horizontais nos tempos T1 (instalação protética), T2 (6 meses de acompanhamento) e T3 (12 meses de acompanhamento). Parâmetros biológicos como nível ósseo ao redor dos implantes (CBL) foram avaliados, alteração CBL (CBLC), comprimento total da coroa (TCL) e relação implante / coroa (ICR) foram calculados digitalmente. Todos os implantes incluídos no estudo foram submetidos à análise do quociente de estabilidade do implante (ISQ) no momento da instalação do implante (T0) e aos 12 meses de função protética (T3). Os dados foram testados estatisticamente. A ICR foi maior no grupo teste do que no grupo controle (p<0,0001). As medidas de CBL no início do estudo foram de 0,21±0,19 mm e 0,32±0,38 mm e em 12 meses 0,65±0,24 mm e 0,87±0,34 mm, respectivamente nos grupos teste e controle. CBLCs e CBL foram semelhantes em todos os momentos (p>0,05). Não foi encontrada correlação entre os parâmetros CBLC e ICR, bem como entre o ISQ e o comprimento do implante. Podemos concluir que padrões e implantes extra curtos podem fornecer resultados clínicos semelhantes na reabilitação protética da mandíbula atrófica ao longo de 12 meses de acompanhamento.

    Resumo em Inglês:

    Abstract The aim of this study was to clinically and radiographically compare extra short and standards implants. Forty-two implants were installed in 10 selected patients. They received prosthetic loading only after the conventional waiting time for osseointegration and the prostheses were made ferulized. Radiographic shots were performed to evaluate vertical and horizontal bone losses at times T1 (prosthetic installation), T2 (6 months follow-up) and T3 (12 months follow-up). Biological parameters such as bone level around the implants (CBL) were evaluated, CBL alteration (CBLC), total crown length (TCL) and implant/crown ratio (ICR) were digitally calculated. All implants included in the study were submitted to the analysis of the implant stability quotient (ISQ) at the time of implant installation (T0) and at 12 months of prosthetic function (T3). Data were statistically tested. The ICR was higher in the test group than in the control group (p<0.0001). The CBL measurements at the beginning of the study were 0.21±0.19 mm and 0.32±0.38 mm and at 12 months 0.65±0.24 mm and 0.87±0.34 mm, respectively in the test and control groups. CBLCs and CBL were similar at all times (p>0.05). No correlation was found between CBLC and ICR parameters, as well as between ISQ and implant length. We may conclude that standards and extra short implants can provide similar clinical results in prosthetic rehabilitation of the atrophic jaw over 12 months of follow-up.
  • Implant Volume Loss, Misfit, Screw Loosening, and Stress In Custom Titanium and Zirconia Abutments Article

    Barbosa Jr, Sales Antônio; Bacchi, Ataís; Barão, Valentim Adelino Ricardo; Silva-Sousa, Yara Teresinha Corrêa; Bruniera, João Felipe; Caldas, Ricardo Armini; Consani, Rafael Leonardo Xediek

    Resumo em Português:

    Resumo O objetivo neste estudo foi verificar o efeito da diminuição de volume do implante, desajuste vertical entre o pilar e plataforma protética, torque de afrouxamento do parafuso protético e distribuição da tensão no parafuso em pilares de titânio e zircônia. Dez pilares personalizados de cada material foram fresados e conectados aos implantes de titânio. A diminuição de volume do implante foi avaliada com microtomografia, o desajuste vertical com microscopia óptica e o torque de afrouxamento do parafuso protético com chave de torque digital. Todas as análises experimentais foram realizadas antes e após aplicação do ciclo mecânico (1.000.000 ciclos, 100 N/2 Hz). Modelos virtuais das estruturas foram criados para análise por elementos finitos e a tensão no parafuso obtida com valores de von Mises. Os dados foram analisados usando teste t independente, análise de varância dois fatores para medidas repetidas e teste de Tukey HSD (a=0,05). Não houve diferença significativa na diminuição de volume do implante para os dois materiais do pilar (p= 0,662). Os pilares de titânio proporcionaram maiores valores de torque de afrouxamento após o ciclo mecânico (p<0,001). O menor desajuste marginal foi obtido com os pilares de titânio antes e após o ciclo mecânico (p<0,001). A distribuição da tensão no parafuso foi similar entre os materiais. Em conclusão, os pilares personalizados de titânio reduziram o desajuste marginal e aumentaram a manutenção do torque dos parafusos protéticos quando comparados aos pilares de zircônia.

    Resumo em Inglês:

    Abstract The aim of this study was to verify the effect of the implant volume loss, vertical misfit between abutment and prosthetic platform, prosthetic screw loosening torque, and screw stress distribution in titanium and zirconia abutments. Ten CAD/CAM system custom abutments of each material were milled and attached to the titanium implants. The implant volume loss was evaluated by microtomography, the vertical misfit with optical microscopy, and digital torque wrench measured the prosthetic screw loosening. All experimental analyses were performed before and after mechanical cycle (1,000,000 cycles, 100 N/2 Hz). Virtual models of the structures were created for finite element analysis, and the stress on the screw obtained with von Mises procedure. Data were analyzed using an independent t-test, two-way ANOVA for repeated measures, and Tukey’s HSD test (a=0.05). There was no significant difference in the implant volume loss for the two abutment materials (p=0.662). Titanium abutments provided higher loosening torque values after mechanical cycling (p<0.001). Lesser marginal misfit was obtained with titanium abutments before and after mechanical cycling (p<0.001). The stress distribution on the screw was similar between abutment materials. In conclusion, CAD/CAM custom titanium abutment reduced the marginal misfit and increased the torque maintenance of prosthetic screws when compared to CAD/CAM custom zirconia abutment.
  • Comparative Analysis of Biofilm Formation on Materials Used for the Fabrication of Implant-Supported Prostheses Article

    Sadid-Zadeh, Ramtin; Willis, Jeffrey; Forgo, Gyula; Haraszthy, Violet

    Resumo em Português:

    Resumo O objetivo deste estudo foi comparar a formação de biofilme em materiais utilizados na confecção de próteses dentárias implantossuportadas. Vinte discos (D = 15 mm, H = 3 mm) foram confeccionados com um dos seguintes materiais restauradores: zircônia tetragonal policristalina estabilizada por ítrio (Y-TZP); titânio comercialmente puro (CP-Ti); ou polimetilmetacrilato (PMMA). As amostras foram polidas seguindo protocolos padrão. Um perfilômetro sem contato (NPFLEX, Bruker, UK) foi usado para avaliar a rugosidade da superfície de cada disco; os resultados foram relatados como Ra (µm). Cinco cepas de bactérias Gram-negativas freqüentemente associadas a peri-implantite, Aggregatibacter actinomycetemcomitans, Candida. albicans, Porphyromonas gingivalis, Prevotella intermedia e Tannerella forsythia, foram cultivadas em discos polidos à mão feitos de PMMA, Y-TZP ou CP-Ti para comparar a formação de biofilme em cada tipo de material. Os resultados foram relatados como unidades formadoras de colônias por mililitro (UFC/mL). Análise de variância a um fator e testes post hoc foram usados ​​para comparar a rugosidade da superfície e a colonização bacteriana nos respectivos materiais. A significância estatística foi estabelecida em a=0,05. Os discos feitos de Y-TZP tiveram um valor Ra significativamente mais alto (350 ± 30 µm) do que os discos de PMMA ou CP-Ti. Os discos fabricados com Y-TZP e CP-Ti podem apresentar menor colonização por bactérias associadas à perimucosite e peri-implantite. Considerando O Y-TZP e CP-Ti são materiais indicados para a confecção de próteses implantossuportadas, considerando a formação de biofilme

    Resumo em Inglês:

    Abstract The purpose of this study was to compare biofilm formation on materials used for the fabrication of implant-supported dental prostheses. Twenty discs (D=15 mm, H=3 mm) were fabricated from one of the following restorative materials: yttria tetragonal zirconia polycrystal (Y-TZP); commercially pure titanium (CP-Ti); or heat-cured polymethyl methacrylate (PMMA). Specimens were polished following standard protocols. A non-contact profilometer (NPFLEX, Bruker, UK) was used to assess the surface roughness of each disk; results were reported as Ra (µm). Five strains of Gram-negative bacteria frequently associated with peri-implantitis, Aggregatibacter actinomycetemcomitans, Candida. albicans, Porphyromonas gingivalis, Prevotella intermedia, and Tannerella forsythia, were cultured on hand-polished discs fabricated from heat-cured PMMA, Y-TZP, or CP-Ti to compare biofilm formation on each type of material. The results were reported as colony-forming units per milliliter (CFU/mL). One-way ANOVA and post hoc tests were used to compare surface roughness and bacterial colonization on the respective materials. Statistical significance was set at a = 0.05. Discs fabricated from Y-TZP had a significantly higher Ra value (350 ± 30 µm) than either PMMA, or CP-Ti discs. Discs fabricated from either Y-TZP and CP-Ti may exhibit less colonization by bacteria associated with peri-mucositis and peri-implantitis. Y-TZP and CP-Ti are suggested materials for fabrication of implant-supported prostheses, considering biofilm formation.
  • Simvastatin-Enriched Macro-Porous Chitosan-Calcium-Aluminate Scaffold for Mineralized Tissue Regeneration Article

    Cassiano, Fernanda Balestrero; Soares, Diana Gabriela; Bordini, Ester Alves Ferreira; Anovazzi, Giovana; Hebling, Josimeri; Costa, Carlos Alberto de Souza

    Resumo em Português:

    Resumo O presente estudo avaliou o potencial odontogênico de células da polpa dental humana (HDPCs) em contato com scaffolds de quitosana contendo aluminato de cálcio (CHAlCa) associado ou não à baixas dosagens de sinvastatina (SV). Scaffolds de quitosana receberam uma suspensão de aluminato de cálcio e foram imersos em soluções contendo a droga. Foram estabelecidos três grupos experimentais: scaffolds de quitosana e aluminato de cálcio (CHAlCa - controle), scaffolds de quitosana-aluminato de cálcio com 0.5 µM SV (CHAlCa-SV0.5), e quitosana-aluminato de cálcio com 1.0 µM SV (CHAlCa-SV1.0). A morfologia e composição foram avaliados por MEV e EDS, respectivamente. Após 14 dias do cultivo das HDPCs sobre os scaffolds, foram avaliados a viabilidade celular, adesão e espalhamento, deposição de matriz mineralizada e expressão gênica de marcadores odontogênicos. Observou-se que as partículas de aluminato de cálcio foram incorporadas à matriz de quitosana, a qual exibiu poros regulares distribuídos por toda sua estrutura. As dosagens selecionadas de sinvastatina foram biocompatíveis com as HDPCs. A concentração de 1 µM de SV induziu intensa expressão de fenótipo odontoblástico pelas HDPCs, demonstrando aumento da deposição de matriz mineralizada e maior expressão de ALP, Col1A1 e DMP-1. Portanto, podemos concluir que a incorporação de aluminato de cálcio e sinvastatina em scaffolds de quitosana apresentou um efeito sinérgico nas HDPCs, favorecendo a diferenciação celular e deposição de matriz mineralizada.

    Resumo em Inglês:

    Abstract The present study evaluated the odontogenic potential of human dental pulp cells (HDPCs) exposed to chitosan scaffolds containing calcium aluminate (CHAlCa) associated or not with low doses of simvastatin (SV). Chitosan scaffolds received a suspension of calcium aluminate (AlCa) and were then immersed into solutions containing SV. The following groups were established: chitosan-calcium-aluminate scaffolds (CHAlCa - Control), chitosan calcium-aluminate with 0.5 µM SV (CHAlCa-SV0.5), and chitosan calcium-aluminate with 1.0 µM SV (CHAlCa-SV1.0). The morphology and composition of the scaffolds were evaluated by SEM and EDS, respectively. After 14 days of HDPCs culture on scaffolds, cell viability, adhesion and spread, mineralized matrix deposition as well as gene expression of odontogenic markers were assessed. Calcium aluminate particles were incorporated into the chitosan matrix, which exhibited regular pores homogeneously distributed throughout its structure. The selected SV dosages were biocompatible with HDPCs. Chitosan-calcium-aluminate scaffolds with 1 µM SV induced the odontoblastic phenotype in the HDPCs, which showed enhanced mineralized matrix deposition and up-regulated ALP, Col1A1, and DMP-1 expression. Therefore, one can conclude that the incorporation of calcium aluminate and simvastatin in chitosan scaffolds had a synergistic effect on HDPCs, favoring odontogenic cell differentiation and mineralized matrix deposition.
  • Analysis of Dentistry YouTube Videos Related To COVID-19 Article

    Ozdede, Melih; Peker, Ilkay

    Resumo em Português:

    Resumo Este estudo teve como objetivo analisar os vídeos disponíveis no YouTube relacionados à odontologia e ao novo coronavírus (COVID-19), visto que não há tal análise na literatura existente. Os termos “dental” e “COVID-19” foram pesquisados no YouTube em 9 de maio de 2020. Os 116 principais vídeos em inglês, com pelo menos 300 visualizações, foram analisados por dois observadores. Os dados foram salvos para cada vídeo, incluindo público-alvo, fonte, país de origem, conteúdo, número de visualizações, tempo assistido, média de visualizações, duração, proporção de gostar/não gostar e utilidade. As pontuações do índice total de informação e qualidade de vídeo (VIQI) foram calculadas, consistindo em índices de fluxo, informação, exatidão, qualidade e precisão. Testes não paramétricos foram usados para análise. Os vídeos analisados ​​foram assistidos 375 mil vezes e totalizaram 20 h de conteúdo. A maioria dos vídeos foi enviada por dentistas (45,7%), com origem nos Estados Unidos (79,3%) e com informações direcionadas aos pacientes (48,3%). Quase metade dos vídeos (47,4%) foram moderadamente úteis. Para a utilidade dos vídeos, foram encontradas diferenças estatisticamente significantes para todos os índices, bem como para os escores totais do VIQI. Uma comparação dos índices de acordo com a relevância dos vídeos mostrou diferenças estatisticamente significativas nas informações dos vídeos e nos índices de precisão e nas pontuações totais do VIQI. Os resultados deste estudo mostraram que os vídeos de odontologia no YouTube relacionados à COVID-19 tiveram um alto número de visualizações; no entanto, os vídeos eram geralmente moderados em qualidade e utilidade.

    Resumo em Inglês:

    Abstract This study aimed to analyze the videos available on YouTube related to dentistry and the novel coronavirus (COVID-19), as there is no such analysis in the existing literature. The terms “dental” and “COVID-19” were searched on YouTube on May 9, 2020. The top 116 English-language videos with at least 300 views were analyzed by two observers. Data was saved for each video, including target audience, source, country of origin, content, number of views, time watched, average views, duration, like/dislike ratio, and usefulness. Total video information and quality index (VIQI) scores were calculated, consisting of flow, information, accuracy, quality, and precision indices. Non-parametric tests were used for analysis. The analyzed videos were viewed 375,000 times and totaled 20 h of content. Most videos were uploaded by dentists (45.7%), originated from the United States (79.3%), and contained information targeted towards patients (48.3%). Nearly half of the videos (47.4%) were moderately useful. For the usefulness of the videos, statistically significant differences were found for all indices as well as total VIQI scores. A comparison of the indices according to the relevance of the videos showed statistically significant differences in the videos’ information and precision indices and total VIQI scores. The results of this study showed that dentistry YouTube videos related to COVID-19 had high view numbers; however, the videos were generally moderate in quality and usefulness.
  • Evaluation of Bite Force and Masticatory Performance: Complete Denture vs Mandibular Overdenture Users Article

    Possebon, Anna Paula da Rosa; Schuster, Alessandra Julie; Bielemann, Amália Machado; Porto, Bruna Leão; Boscato, Noéli; Faot, Fernanda

    Resumo em Português:

    Resumo Este estudo observacional transversal com 24 participantes teve como objetivo avaliar as diferenças na força de mordida (FM) e na PM (performance mastigatória) entre usuários de prótese total convencional (PTC) e de overdenture mandibular (OM) e a correlação entre essas variáveis. O teste de FM foi realizado bilateralmente com um dispositivo de força oclusal. Durante o teste de PM, os pacientes foram solicitados a mastigar uma porção padronizada de Optocal por 40 ciclos mastigatórios. O teste de Shapiro Wilk foi empregado para verificar a normalidade dos dados, o teste T de Student para identificar diferenças entre os grupos e os coeficientes de correlação de Pearson para investigar inter-relações entre variáveis. Uma regressão linear múltipla foi realizada pelo método stepwise. Valores de p≤0,05 foram considerados estatisticamente significantes. Diferentemente dos usuários de OM, os usuários de PTC apresentaram uma diferença significativa (34%) na FM entre o lado dominante e o não dominante (p=0,04). Os usuários de OM apresentaram FM significativamente maior (p=0,01) sem apresentar um lado dominante (p=0,38) e obtiveram PM significativamente melhor nos seguintes parâmetros: os valores de PMX50 diminuíram 27,25% (p=0,01), PMB diminuiu em 48,38% (p=0,01), e EM 5.6 diminuiu 53,25% (p=0,02), enquanto EM2.8 aumentou 151,57% (p=0,01). A FM e PMX50 no grupo de usuários da IMO foram negativamente correlacionados (-0,57;p=0,05); esse coeficiente de correlação foi o único parâmetro incluído no modelo de regressão multivariada. Os usuários da OM possuem maior FM e melhor performance mastigatória do que os usuários de PTC, observados principalmente na redução do tamanho das partículas mastigadas. A PM está correlacionada com um maior FM nos usuários da OM através de uma melhor trituração de partículas.

    Resumo em Inglês:

    Abstract: This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally with an occlusal force device. During the MP test, patients were asked to chew Optocal particles for 40 cycles. The Shapiro Wilk test was employed to verify the normality of the data, the student t test to identify differences between groups, and Pearson’s correlation to investigate interrelationships between variables. A multiple linear regression was subsequently performed via the stepwise method. P values ≤0.05 were considered statistically significant. Unlike IMO users, CCD users presented a significant difference (25.6%) in BF between the dominant and non-dominant chewing side (p=0.04). IMO users presented significantly higher BF (p=0.01) without presenting a dominant side (p=0.38), and also performed significantly better for the following MP parameters: MPX50 values decreased by 27.25% in IMO users (p=0.01), MPB decreased by 48.38% (p=0.01), and ME 5.6 decreased by 53.25% (p=0.02), while ME2.8 increased by 151.57% (p=0.01). The BF and MPX50 in the IMO wearers group were negatively correlated (-0.57; p=0.05); this correlation coefficient was the only parameter included in the multivariate regression model. IMO users have higher BF and better masticatory performance than CCD users, especially in terms of chewed particles size reduction. MP is correlated with a higher BF in IMO users through better particle trituration.
  • Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision Article

    Melo, Andrélia Maciel; Vivacqua-Gomes, Nilton; Bernardes, Ricardo Affonso; Vivan, Rodrigo Ricci; Duarte, Marco Antônio Húngaro; Vasconcelos, Bruno Carvalho de

    Resumo em Português:

    Resumo O objetivo deste estudo foi avaliar a influência de diferentes protocolos de pré-alargamento cervical (ausente, conservador e convencional) na precisão dos localizadores eletrônicos foraminais (LEFs) Root ZX II, Raypex 6 e RomiApex A-15. Vinte molares inferiores com raízes mesiais do tipo IV de Vertucci foram submetidos à exploração endodôntica e confirmação da patência foraminal. Sob ampliação de 16x, seus comprimentos reais (CR) foram medidos e registrados (CR1). Os canais foram então irrigados com hipoclorito de sódio a 2,5% e medidos eletronicamente (ME1) utilizando o modelo em alginato; todas as medidas foram realizadas em triplicata por um operador cego, utilizando limas endodônticas ajustadas introduzidas até o forame apical. Os procedimentos de pré-alargamento cervical foram realizados sequencialmente com os instrumentos #25/.06 (conservador) e #25/.12 (convencional); novas determinações de CRs foram realizadas após cada protocolo de preparação cervical (CR2/CR3), da mesma forma que as medidas eletrônicas (ME2/ME3). O erro dos dispositivos (mm) foi avaliado considerando a diferença entre CRs e MEs em cada estágio de preparação; sua precisão foi estabelecida adotando ± 0,5 mm como margem de tolerância. O erro dos LEFs reduziu significativamente após o protocolo convencional de alargamento cervical (p<0,05), o que não ocorreu após o conservador. Os melhores valores de precisão foram observados após a preparação convencional como 90% (Root ZX II), 97,5% (Raypex 6) e 92,5% (RomiApex A-15). Não foram encontradas diferenças significantes nas comparações entre os LEFs, independentemente do protocolo cervical testado (p>0,05). Sob as condições testadas, pode-se concluir que os LEFs avaliados foram precisos. Além disso, os protocolos de alargamento influenciam sua precisão, onde o menos conservador produziu os melhores resultados.

    Resumo em Inglês:

    Abstract: The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci’s type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p<0.05), which not occur after the conservative one. The best precisions values were noted after conventional preparation as 90% (Root ZX II), 97.5% (Raypex 6), and 92.5% (RomiApex A-15). No significant differences were found in EFLs comparisons, regardless of the coronal protocol tested (p>0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy’s, where the less conservative one produced the best results.
  • Effect of Silver Antibacterial Agents on Bond Strength of Fiber Posts to Root Dentin Article

    Shafiei, Fereshteh; Memarpour, Mahtab; Jowkar, Zahra

    Resumo em Português:

    Resumo Este estudo foi conduzido para avaliar se a irrigação de pré-tratamento antibacteriano com nanopartículas de prata (SNPs) e fluoreto de diamina de prata (SDF) tem algum efeito na resistência de união de pinos de fibra cimentados com três tipos de cimentos resinosos no espaço do canal radicular. Cinquenta e quatro raízes de incisivos centrais superiores tratadas endodonticamente foram preparadas para cimentação de pino de fibra (FRC Postec Plus NO.3, Ivoclar Vivadent) e divididas em nove grupos em termos de três tipos de cimento e dois pré-tratamentos com agentes antibacterianos de prata. Os cimentos foram os seguintes: um cimento etch-and-rinse (ER, Excite DSC / Variolink N), um cimento autocondicionante (SE, ED Primer / Panavia F2.0) e um cimento autoadesivo (SA, Panavia SA Luting Plus). Para cada cimento, o grupo controle foi sem tratamento e dois grupos experimentais foram com SNPs e SDF tratamentos que foram usados após o condicionamento ácido para o cimento ER e após o tratamento com EDTA para os cimentos SE e SA. Após a cimentação do pilar de fibra, cada raiz ligada foi seccionada horizontalmente em microclimas de 1 mm de espessura para criar duas fatias para cada região da raiz (apical, média e coronal) e submetida ao teste de resistência de união por push-out (PBS). Os dados em MPa foram analisados ​​com ANOVA de dois fatores e teste de Tukey (p = 0,05). A interação do tipo de pré-tratamento e tipo de cimento foi significativa (p<0,001). SNPs e SDF aumentaram significativamente o PBS com cimento ER (p≤0,04). Este efeito positivo também foi marginalmente significativo para SDF com cimento SE (p = 0,049). Para o cimento SA, os SNPs mostraram um efeito positivo significativo, mas o SDF teve um efeito adverso significativo no PBS (p <0,001). O efeito do pré-tratamento com agentes antibacterianos de prata antes da cimentação adesiva dos pinos de fibra depende do cimento resinoso utilizado. Ao contrário dos SNPs com efeito benéfico ou nenhum efeito significativo na adesão para todos os cimentos, o SDF exibiu um efeito deletério com o cimento autoadesivo.

    Resumo em Inglês:

    Abstract This study was conducted to evaluate whether antibacterial pretreatment irrigation with silver nanoparticles (SNPs) and silver diamine fluoride (SDF) has any effect on bond strength of fiber posts cemented with three types of resin cements in root canal space. Fifty-four endodontically treated maxillary central incisor roots were prepared for fiber post (FRC Postec Plus NO.3, Ivoclar Vivadent) cementation and divided into nine groups in terms of three cement types and two pretreatments with silver antibacterial agents. The cements were as follows: an etch-and-rinse cement (ER, Excite DSC/Variolink N), a self-etch cement (SE, ED Primer/Panavia F2.0), and a self-adhesive cement (SA, Panavia SA Luting Plus). For each cement, the control group was with no treatment and two experimental groups were with SNPs and SDF treatments that were used after acid-etching for ER cement and after EDTA treatment for SE and SA cements. After fiber post cementation, each bonded root was horizontally sectioned into 1-mm thickness microslices to create two slices for each root region (apical, middle and coronal) and underwent push-out bond strength (PBS) test. Data in MPa were analyzed with two-way ANOVA and Tukey test (p=0.05). The interaction of the pretreatment type and cement type was significant (p<0.001). SNPs and SDF significantly increased PBS with ER cement (p≤0.04). This positive effect was also marginally significant for SDF with SE cement (p=0.049). For SA cement, SNPs showed a significant positive effect, but SDF had a significant adverse effect on PBS (p<0.001). The effect of pretreatment with silver antibacterial agents prior to adhesive cementation of fiber posts depends on the resin cement used. Contrary to SNPs with beneficial or no significant effect on bonding for all cements, SDF exhibited a deleterious effect with self-adhesive cement.
  • Effects of 1-Ethyl-3-(3-Dimethylaminopropyl) Carbodiimide on Adhesion of Posts in Teeth Obturated With Different Sealers Article

    Coelho, Beatriz Serrato; Tomazinho, Flávia Sens Fagundes; Leonardi, Denise Piotto; Scaini, Fabrício; Gabardo, Marilisa Carneiro Leão; Lara, Rafaela Mariana de; Baratto-Filho, Flares

    Resumo em Português:

    Resumo O objetivo deste estudo foi avaliar o efeito da 1-etil-3- (3-dimetilaminopropil) carbodiimida (EDC) na resistência de união de pinos de fibra de vidro em canais radiculares obturados com diferentes cimentos endodônticos. Setenta e oito pré-molares inferiores foram obturados com três cimentos endodônticos (n=26): Endofill (END), AH Plus (AHP) e Endosequence BC Sealer (EBS). Após o preparo do espaço para pino, dois subgrupos formaram-se conforme a cimentação dos pinos (n=13): com EDC e sem EDC (controle - CON). Os espécimes foram submetidos ao teste pull-out, classificação do modo de falha e avaliação da superfície do canal radicular por microscopia eletrônica de varredura após o deslocamento. Quanto à força de resistência de união, uma diferença estatisticamente significativa ocorreu entre os subgrupos EDC e CON apenas no END (p=0,001). Não foi detectada diferença entre os subgrupos CON (p=0,339). Contudo, no subgrupo EDC, o AHP apresentou maiores valores (END versus AHP: p=0,001; AHP versus EBS: p=0,016). Acerca da classificação dos modos de falha, o escore 1 (≥50% de cimento) foi o mais comumente observado, exceto para END + EDC. Restos de cimentos endodônticos e cimentos resinosos foram encontrados no terço cervical, mas sem diferença estatística (p=0,269), enquanto no terço médio, houve diferença (p=0,004). Em conclusão, o EDC diminui a resistência de união quando associado ao cimento END, sem alterar o modo de falha entre o cimento resinoso e o pino de fibra de vidro. O melhor desempenho foi observado quanto o EDC foi usado com o cimento AHP.

    Resumo em Inglês:

    Abstract The aim of this study was to evaluate the effect of 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) on bond strength of fiberglass posts in root canals obturated with different endodontic sealers. Seventy-eight mandibular premolars were obturated with three sealers (n=26): Endofill (END), AH Plus (AHP), and Endosequence BC Sealer (EBS). After preparation of the post space, two subgroups were formed according to the cementation of the posts (n=13): with EDC (EDC), and without EDC (control - CON). The specimens were submitted to a pull-out test, failure mode classification, and root canal surface evaluation by scanning electron microscopy after post displacement. Regarding the bond strength, a significant difference between the EDC and CON subgroups occurred only in the END (p=0.001). No difference was detected among the CON subgroups (p=0.339). However, among the EDC subgroups, AHP presented significantly higher values (END versus AHP: p=0.001; AHP versus EBS: p=0.016). Upon classification of failure modes, score 1 (≥ 50% of cement) was the most commonly observed, except for the END + EDC. Remains of endodontic sealers and resin cements were found in the cervical third, but without statistical difference (p=0.269), while in the middle third, difference occurred (p=0.004). In conclusion, EDC decreases bond strength when associated with END sealer, without changing the failure mode between the resin cement and fiberglass post. The best performance was observed when EDC was combined with AHP sealer.
  • Cyclodextrin and TiF4 Nanocomplex on Enamel Demineralization Article

    Vieira, Thiago; Alexandria, Adílis K.; Amaral, Lilian H.; Neves, Aline de A.; Lopes, Ricardo T.; Cabral, Lúcio M.; Valença, Ana M. G.; Maia, Lucianne C.

    Resumo em Português:

    Resumo O objetivo deste estudo foi avaliar o efeito da 1-etil-3- (3-dimetilaminopropil) carbodiimida (EDC) na resistência de união de pinos de fibra de vidro em canais radiculares obturados com diferentes cimentos endodônticos. Setenta e oito pré-molares inferiores foram obturados com três cimentos endodônticos (n=26): Endofill (END), AH Plus (AHP) e Endosequence BC Sealer (EBS). Após o preparo do espaço para pino, dois subgrupos formaram-se conforme a cimentação dos pinos (n=13): com EDC e sem EDC (controle - CON). Os espécimes foram submetidos ao teste pull-out, classificação do modo de falha e avaliação da superfície do canal radicular por microscopia eletrônica de varredura após o deslocamento. Quanto à força de resistência de união, uma diferença estatisticamente significativa ocorreu entre os subgrupos EDC e CON apenas no END (p=0,001). Não foi detectada diferença entre os subgrupos CON (p=0,339). Contudo, no subgrupo EDC, o AHP apresentou maiores valores (END versus AHP: p=0,001; AHP versus EBS: p=0,016). Acerca da classificação dos modos de falha, o escore 1 (≥50% de cimento) foi o mais comumente observado, exceto para END + EDC. Restos de cimentos endodônticos e cimentos resinosos foram encontrados no terço cervical, mas sem diferença estatística (p=0,269), enquanto no terço médio, houve diferença (p=0,004). Em conclusão, o EDC diminui a resistência de união quando associado ao cimento END, sem alterar o modo de falha entre o cimento resinoso e o pino de fibra de vidro. O melhor desempenho foi observado quanto o EDC foi usado com o cimento AHP.

    Resumo em Inglês:

    Abstract The aim of this study was to assess the effect of a newly developed nanocomplex formed of hydroxypropyl-b-cyclodextrin and 1% titanium tetrafluoride (TiF4) after distinct complexation periods (12/72 h) on demineralization of bovine enamel in vitro. Enamel blocks (n=60) were allocated in different groups: Mili-Q water, hydroxypropyl-b-cyclodextrin, 1% TiF4, hydroxypropyl-b-cyclodextrin + 1% TiF4 after 12 h of complexation and hydroxypropyl-b-cyclodextrin + 1% TiF4 after 72 h of complexation. The samples were evaluated by surface microhardness, cross-sectional microhardness and micro-CT. Scanning electron microscopy and energy dispersive X-ray spectrometry (SEM/EDX) were also obtained. Hydroxypropyl-b-cyclodextrin + 1% TiF4 after 12 h complexation resulted in lower percentage of surface microhardness loss compared to Mili-Q water, hydroxypropyl-b-cyclodextrin, 1% TiF4 and hydroxypropyl-b-cyclodextrin + 1% TiF4 after 72 h of complexation group, with a large effect size (from 1.307 to 2.943) and high power (84.9 to 99%). All groups resulted in similar integrated mineral loss (ΔZ) obtained by both internal microhardness and micro-CT techniques. Enamel treated with TiF4 and TiF4 + hydroxypropyl-b-cyclodextrin groups showed a TiO2 glaze-layer, while EDX evaluation identified Ti. The solution containing the inclusion complex of hydroxypropyl-b-cyclodextrin + TiF4 with 12 h of complexation period demonstrated a significant ability to reduce surface demineralization of sound enamel under an artificial cariogenic challenge.
  • Physical-Mechanical Properties of Bulk Fill Composites Submitted to Biodegradation by Streptococcus mutans Article

    Camassari, Jessica Rodrigues; Correr-Sobrinho, Lourenço; Correr, Américo Bortolazzo; Puppin-Rontani, Julia; Stipp, Rafael Nobrega; Puppin-Rontani, Regina Maria; Paula, Andreia Bolzan de

    Resumo em Português:

    Resumo O objetivo deste estudo foi avaliar a influência do biofilme de S. mutans na rugosidade (Ra), brilho (GU), dureza superficial (KHN) e resistência à flexão (FS) de compósitos de Bulk Fill de alta viscosidade. Foram utilizados Filtek Bulk Fill (FBF), Tetric N Ceram Bulk Fill (TNC), X-tra fil Bulk Fill (XF) e Filtek Z350 (FZ). Dez discos de cada compósito foram preparados para Ra, KHN e GU e 20 barras para o FS. Após 24 h, os espécimes foram polidos e as análises iniciais realizadas. As amostras foram esterilizadas e submetidas a biodegradação por 7 dias e as análises finais foram realizadas. Amostras representativas de cada grupo foram avaliadas no Microscópio Eletrônico de Varredura. Os dados foram submetidos à ANOVA dois fatores e teste de Tukey. XF apresentou os maiores valores (p<0,05) de Ra antes e após a biodegradação (0,1251; o00,3100) e FZ (0,1443) os menores após a biodegradação (p<0,05). Os maiores valores de GU (p<0,05) foram observados para FZ (71,7; 62) e FBF (69,0; 64,6), e os mais baixos (p<0,05) para TNC (61,4; 53,3) e XF (58,5; 53,5), ambos antes e depois da biodegradação. Para KHN, os valores mais altos foram obtidos por XF (151,7; 106), e os (p<0,05) valores mais baixos para TNC (62,2; 51,8), antes e depois da biodegradação. Os maiores valores (p <0,05) de FS foram observados para a FZ (127,6) e os menores (p<0,05) para a TNC (86,9); após biodegradação, o XF (117,7) apresentou os maiores valores (p<0,05) em comparação ao TNC e FZ. Em conclusão, a biodegradação aumentou o Ra e diminuiu a GU e a KHN para todos. Em relação à FS, a degradação promoveu uma diminuição significativa apenas para a FZ.

    Resumo em Inglês:

    Abstract The aim of this study was to evaluate the Streptococcus mutans biofilm influence on the roughness (Ra), gloss (GU), surface hardness (KHN) and flexural strength (FS) of high viscosity bulk fill composites. Filtek Bulk Fill (FBF), Tetric N Ceram Bulk Fill (TNC), X-tra fil Bulk Fill (XF) and Filtek Z350 (FZ) were used. Ten discs of each composite were prepared for Ra, KHN and GU and 20 bars for the FS. After 24 h, specimens were polished and initial analyzes performed. Samples were sterilized and subjected to biodegradation for 7 days and final analyzes performed. Representative samples of each group were evaluated in Scanning Electron Microscope. Data were submitted to ANOVA two factors and Tukey test. XF presented the highest values (p<0.05) of Ra before and after biodegradation (0.1251; 0.3100), and FZ (0.1443) the lowest after biodegradation (p<0.05). The highest GU values (p<0.05) were observed for FZ (71.7; 62) and FBF (69.0; 64.6), and the lowest (p<0.05) for TNC (61.4; 53.3) and XF (58.5; 53.5), both before and after biodegradation. For KHN the highest values were obtained by XF (151.7; 106), and the (p< 0.05) lowest values for TNC (62.2; 51.8), both before and after biodegradation. The highest values (p<0.05) of FS were observed for FZ (127.6) and the lowest (p<0.05) for TNC (86.9); after biodegradation, XF (117.7) presented the highest (p<0.05) values compared to TNC and FZ.” In conclusion, biodegradation increased Ra and decreased GU and KHN for all. Concerning FS, degradation provided a significant decreased value only for FZ.
  • Does Pigment Incorporation into Regular Composite Resins for Posterior Buildups Alter Their Bond Strength? Article

    Dias, Flaviana Alves; Conto, Maria Verônica Rodrigues; Guiraldo, Ricardo Danil; Geha, Omar; Paloco, Eloisa Aparecida Carlesse; Fernandes, Thais Maria Freire; Berger, Sandrine Bittencourt

    Resumo em Português:

    Resumo Levantes de mordida posterior são dispositivos para o tratamento ortodôntico confeccionados com resinas compostas ou materiais ionoméricos. Cuidado com a remoção destes se faz necessário para proteção da superfície dentária; para tanto, materiais pigmentados são preferidos por proporcionar melhor visualização. Este estudo propõe uma técnica de pigmentação experimental de resinas compostas convencionais, avaliando a resistência ao microcisalhamento (µ-SBT) na interface de união da resina experimental e superfície de esmalte dental e comparando-a com materiais comercialmente disponíveis para a confecção de levantes de mordida. Quarenta e oito superfícies de dentes humanos foram selecionadas aleatoriamente e divididos em quatro grupos (n=12), de acordo com o material adesivo utilizado: C (Controle, resina composta convencional); P (pigmentação experimental da resina composta convencional); UBL (Ultra Band Lok®); OB (Ortho Bite®). Microcilindros foram preparados para cada tipo de compósito utilizando uma matriz de silicone. As amostras foram mantidas em água destilada por 24h a 37°C, antes da realização do µ-SBT. Os padrões de fratura foram avaliados através de uma lupa estereoscópica com magnificação de 10x. ANOVA com pós teste de Fisher e teste de Dunnett foram utilizados para avaliar os dados. As médias obtidas do µ-SBT ± desvio padrão (MPa) foram: C (39.98a±13.0), P (40.09a± 14.3); UBL (33.26ab±8.6); OB (28.70b±5.5). O tipo de fratura mais prevalente foi a adesiva (80.4%). Além disso, não foi observada correlação estatisticamente significante entre os valores de resistência de união e os padrões de fratura. A técnica de pigmentação experimental não alterou os resultados de µ-SBT da resina composta convencional e mostrou adesividade semelhante à dos compósitos modificados por poliácidos utilizados neste estudo.

    Resumo em Inglês:

    Abstract Posterior build-ups are auxiliary devices to orthodontic treatment which are made with resin-based or glass ionomer composites. Their removal requires care to protect the tooth surface, therefore, pigmented materials are preferred for a better visualization. This study proposed a pigmentation experimental technique of a regular composite resin, evaluating the microshear bond strength test (µ-SBT) of this experimental pigmented resin and comparing with a blue-colored polyacid-modified composite resin, used for posterior buildups. Forty-eight buccal and lingual surfaces of human teeth were used and randomly divided into 4 groups (n=12). The groups were divided into: C (control), regular composite resin; P, regular composite resin pigmented; UBL, Ultra Band Lok™; OB, Ortho Bite™. The composites were bonded using a matrix to obtain microcylinders and prepared for each experimental groups. The samples were then stored in distilled water for 24h at 37°C followed by a µ-SBT. The types of bond failures were evaluated using a stereoscopic magnifying glass (10×). The data were analyzed by ANOVA with Fisher post hoc and Dunnett´s test. Means of µ-SBT± standard deviation (MPa) were: C (39.98a±13.0), P (40.09a± 14.3); UBL (33.26ab±8.6); OB (28.70b±5.5). The most prevalent type of failure was adhesive (80.4%). Further, was not observed a statistically significant correlation between the bond strength values and failure patterns. The pigmentation of a commercially available resin did not alter the µ-SBT and exhibited similar adhesiveness as a polyacid-modified composite resin.
  • Physical Properties of Glass Ionomer Cement Containing Pre-Reacted Spherical Glass Fillers Article

    Panpisut, Piyaphong; Monmaturapoj, Naruporn; Srion, Autcharaporn; Toneluck, Arnit; Phantumvanit, Prathip

    Resumo em Português:

    Resumo O objetivo deste estudo foi avaliar o efeito de diferentes fases líquidas comerciais (Ketac, Riva e Fuji IX) e o uso de partículas esféricas de vidro pré-reagido (SPG) na maturação do cimento, liberação de flúor, força de compressão (CS) e resistência biaxial à flexão (BFS) de cimentos de ionômero de vidro (GICs) experimentais. Os GICs experimentais (Ketac_M, Riva_M, FujiIX_M) foram preparados pela mistura de partículas SPG com fases líquidas comerciais usando a proporção de pó para massa líquida de 2,5: 1. O FTIR-ATR foi usado para avaliar a maturação dos GICs. O coeficiente de difusão do flúor (DF) e a liberação cumulativa de flúor (CF) em água deionizada foram determinados usando o eletrodo específico do íon fluoreto (n = 3). CS e BFS em 24 h também foram testados (n = 6). GICs comerciais foram usados como comparações. Riva e Riva_M exibiram rápida formação de sal de poliacrilato. Os maiores DF e CF foram observados com Riva_M (1,65x10-9 cm2/s) e Riva (77 ppm), respectivamente. O uso de partículas SPG melhorou o DF de GICs em média de ~ 2,5x10-9 cm2/s a ~ 3,0x10-9 cm2/s, mas reduziu o CF dos materiais em média de ~ 51 ppm a ~ 42 ppm. O CS e BFS de Ketac_M (144 e 22 MPa) e Fuji IX_M (123 e 30 MPa) foram comparáveis aos materiais comerciais. Usar SPG com Riva reduziu significativamente CS e BFS de 123 MPa para 55 MPa e 42 MPa para 28 MPa, respectivamente. O uso de SPG partículas melhorou o DF, mas reduziu o CF dos GICs. O uso de partículas SPG com líquidos Ketac ou Fuji IX proporcionou resistência comparável aos materiais comerciais.

    Resumo em Inglês:

    Abstract The aim of this study was to assess the effect of different commercial liquid phases (Ketac, Riva, and Fuji IX) and the use of spherical pre-reacted glass (SPG) fillers on cement maturation, fluoride release, compressive (CS) and biaxial flexural strength (BFS) of experimental glass ionomer cements (GICs). The experimental GICs (Ketac_M, Riva_M, FujiIX_M) were prepared by mixing SPG fillers with commercial liquid phases using the powder to liquid mass ratio of 2.5:1. FTIR-ATR was used to assess the maturation of GICs. Diffusion coefficient of fluoride (DF) and cumulative fluoride release (CF) in deionized water was determined using the fluoride ion specific electrode (n=3). CS and BFS at 24 h were also tested (n=6). Commercial GICs were used as comparisons. Riva and Riva_M exhibited rapid polyacrylate salt formation. The highest DF and CF were observed with Riva_M (1.65x10-9 cm2/s) and Riva (77 ppm) respectively. Using SPG fillers enhanced DF of GICs on average from ~2.5x10-9 cm2/s to ~3.0x10-9 cm2/s but reduced CF of the materials on average from ~51 ppm to ~42 ppm. The CS and BFS of Ketac_M (144 and 22 MPa) and Fuji IX_M (123 and 30 MPa) were comparable to commercial materials. Using SPG with Riva significantly reduced CS and BFS from 123 MPa to 55 MPa and 42 MPa to 28 MPa respectively. The use of SPG fillers enhanced DF but reduced CF of GICs. Using SPG with Ketac or Fuji IX liquids provided comparable strength to the commercial materials.
  • Errata: Infrared Light-Emitting Diode (LED) Effects on Orthodontic Tooth Movement Errata

Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br