Acessibilidade / Reportar erro
Journal of Applied Oral Science, Volume: 19, Número: 3, Publicado: 2011
  • The Journal of Applied Oral Science will start the publication of online ahead of print articles in SciELO, MEDLINE and ISI Web of Knowledge Editorial

    Santos, Carlos F.
  • Pulp tissue from primary teeth: new source of stem cells Original Articles

    Telles, Paloma Dias; Machado, Maria Aparecida de Andrade Moreira; Sakai, Vivien Thiemy; Nör, Jacques Eduardo

    Resumo em Inglês:

    SHED (stem cells from human exfoliated deciduous teeth) represent a population of postnatal stem cells capable of extensive proliferation and multipotential differentiation. Primary teeth may be an ideal source of postnatal stem cells to regenerate tooth structures and bone, and possibly to treat neural tissue injury or degenerative diseases. SHED are highly proliferative cells derived from an accessible tissue source, and therefore hold potential for providing enough cells for clinical applications. In this review, we describe the current knowledge about dental pulp stem cells and discuss tissue engineering approaches that use SHED to replace irreversibly inflamed or necrotic pulps with a healthy and functionally competent tissue that is capable of forming new dentin.
  • Effect of incorporation of 2-tert-butylaminoethyl methacrylate on flexural strength of a denture base acrylic resin Original Articles

    Paleari, André Gustavo; Marra, Juliê; Pero, Ana Carolina; Rodriguez, Larissa Santana; Ruvolo-Filho, Adhemar; Compagnoni, Marco Antonio

    Resumo em Inglês:

    Polymethyl methacrylate (PMMA) resins have commonly been used as a denture base material. However, denture bases may act as a reservoir for microorganisms and contribute to oral diseases in denture wearers. It is hypothesized that the 2-tert-butylaminoethyl methacrylate (TBAEMA) incorporated to acrylic resins should have antimicrobial activity related to the presence of amino groups on acrylic resin surface. OBJECTIVES: The objectives of this study were to evaluate the presence of amino groups on acrylic resin surface and the influence on flexural strength after incorporation of TBAEMA. MATERIAL AND METHODS: Six groups were divided according to the concentration of TBAEMA incorporated to acrylic resin (Lucitone 550): 0, 0.5, 1.0, 1.5, 1.75 and 2%. Specimens surface were evaluated by Electron Spectroscopy for Chemical Analysis (ESCA) to detect the presence of amino groups, represented by nitrogen ratios. Flexural strength of the specimens was tested and results were analyzed by ANOVA and Tukey's test (α=0.05). RESULTS: Different nitrogen ratios were observed on specimen surfaces: 0, 0.13, 0.74, 0.66, 0.92 and 0.33% for groups 0, 0.5, 1.0, 1.5, 1.75, and 2%, respectively. Significant differences were found for flexural strength (p<0.001). The mean flexural strength values were 98.3±3.9, 93.3±3.2, 83.9±2.1, 82.8±5.2, 71.2±5.1 and 17.3±3.2 MPa for groups 0, 0.5, 1.0, 1.5, 1.75, and 2%, respectively. CONCLUSION: Within the limitations of this study, the incorporation of TBAEMA results in the presence of the potentially antimicrobial amino groups on specimen surfaces, but affect the flexural strength, depending on the concentration of TBAEMA.
  • Evaluation of the color stability of two techniquesfor reproducing artificial irides after microwave polymerization Original Articles

    Goiato, Marcelo Coelho; Santos, Daniela Micheline dos; Moreno, Amália; Gennari-Filho, Humberto; Pellizzer, Eduardo Piza

    Resumo em Inglês:

    The use of ocular prostheses for ophthalmic patients aims to rebuild facial aesthetics and provide an artificial substitute to the visual organ. Natural intemperate conditions promote discoloration of artificial irides and many studies have attempted to produce irides with greater chromatic paint durability using different paint materials. OBJECTIVES: The present study evaluated the color stability of artificial irides obtained with two techniques (oil painting and digital image) and submitted to microwave polymerization. MATERIAL AND METHODS: Forty samples were fabricated simulating ocular prostheses. each sample was constituted by one disc of acrylic resin N1 and one disc of colorless acrylic resin with the iris interposed between the discs. The irides in brown and blue color were obtained by oil painting or digital image. The color stability was determined by a reflection spectrophotometer and measurements were taken before and after microwave polymerization. Statistical analysis of the techniques for reproducing artificial irides was performed by applying the normal data distribution test followed by 2-way ANOVA and Tukey HSD test (α=.05). RESULTS: Chromatic alterations occurred in all specimens and statistically significant differences were observed between the oil-painted samples and those obtained by digital imaging. There was no statistical difference between the brown and blue colors. Independently of technique, all samples suffered color alterations after microwave polymerization. CONCLUSION: The digital imaging technique for reproducing irides presented better color stability after microwave polymerization.
  • Composite resin color stability: influence of light sources and immersion media Original Articles

    Domingos, Patricia Aleixo dos Santos; Garcia, Patrícia Petromilli Nordi Sasso; Oliveira, Ana Luisa Botta Martins de; Palma-Dibb, Regina Guenka

    Resumo em Inglês:

    OBJECTIVE: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. MATERIAL AND METHODS: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). RESULTS: High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - ΔE=2.05; XL 3000 - ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. CONCLUSION: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.
  • Dental caries experience, oral health status and treatment needs of dental patients with autism Original Articles

    Jaber, Mohamed Abdullah

    Resumo em Inglês:

    OBJECTIVES: Autism is a lifelong neurodevelopmental disorder. The aims of this study were to investigate whether children with autism have higher caries prevalence, higher periodontal problems, or more treatment needs than children of a control group of non-autistic patients, and to provide baseline data to enable comparison and future planning of dental services to autistic children. MATERIAL AND METHODS: 61 patients with autism aged 6-16 years (45 males and 16 females) attending Dubai and Sharjah Autism Centers were selected for the study. The control group consisted of 61 non-autistic patients chosen from relatives or friends of autistic patients in an attempt to have matched age, sex and socioeconomic status. Each patient received a complete oral and periodontal examination, assessment of caries prevalence, and caries severity. Other conditions assessed were dental plaque, gingivitis, restorations and treatment needs. Chi-square and Fisher's exact test of significance were used to compare groups. RESULTS: The autism group had a male-to-female ratio of 2.8:1. Compared to controls, children with autism had significantly higher decayed, missing or filled teeth than unaffected patients and significantly needed more restorative dental treatment. The restorative index (RI) and Met Need Index (MNI) for the autistic children were 0.02 and 0.3, respectively. The majority of the autistic children either having poor 59.0% (36/61) or fair 37.8% (23/61) oral hygiene compared with healthy control subjects. Likewise, 97.0% (59/61) of the autistic children had gingivitis. CONCLUSIONS: Children with autism exhibited a higher caries prevalence, poor oral hygiene and extensive unmet needs for dental treatment than non-autistic healthy control group. Thus oral health program that emphasizes prevention should be considered of particular importance for children and young people with autism.
  • Apoptosis and survivability of human dental pulp cells under exposure to Bis-GMA Original Articles

    Yano, Junya; Kitamura, Chiaki; Nishihara, Tatsuji; Tokuda, Masayuki; Washio, Ayako; Chen, Ker-Kong; Terashita, Masamichi

    Resumo em Inglês:

    OBJECTIVE: In the present study, we examined whether 2, 2-bis [4-(2-hydroxy-3-methacryloxypropoxy) phenyl] propane (Bis-GMA) has effects on LSC2 cells, human dental pulp cell line. MATERIAL AND METHODS: The viability, cell cycle, and morphology of LSC2 cells were analyzed after exposure to several different concentrations of Bis-GMA. The recovery of viability of Bis-GMA exposed cells was also analyzed in the condition without Bis-GMA. Further, penetration of Bis-GMA to dentin disc was examined using isocratic high-performance liquid chromatography. RESULTS: There was a concentration-dependent decrease in cell proliferation and an increase in cell number in the sub-G1 population after exposure to Bis-GMA. Furthermore, the cells showed typical characteristics of apoptotic cells after the exposure to high concentration of Bis-GMA. In contrast, cells exposed to lower concentrations of Bis-GMA recovered their viability after being cultured without Bis-GMA. We also found that Bis-GMA is capable of penetrating 1-mm-thick dentin discs, though the penetrated concentration was lower than that showing cytotoxicity. CONCLUSION: These results suggest that Bis-GMA has cytotoxic effects, though dental pulp exposed to lower concentrations is able to recover their viability when Bis-GMA is removed.
  • Surface roughness of orthodontic band cements with different compositions Original Articles

    Sande, Françoise Hélène van de; Silva, Adriana Fernandes da; Michelon, Douver; Piva, Evandro; Cenci, Maximiliano Sérgio; Demarco, Flávio Fernando

    Resumo em Inglês:

    OBJECTIVES: The present study evaluated comparatively the surface roughness of four orthodontic band cements after storage in various solutions. MATERIAL AND METHODS: Eight standardized cylinders were made from 4 materials: zinc phosphate cement (ZP), compomer (C), resin-modified glass ionomer cement (RMGIC) and resin cement (RC). Specimens were stored for 24 h in deionized water and immersed in saline (pH 7.0) or 0.1 M lactic acid solution (pH 4.0) for 15 days. Surface roughness readings were taken with a profilometer (Surfcorder SE1200) before and after the storage period. Data were analyzed by two-way ANOVA and Tukey's test (comparison among cements and storage solutions) or paired t-test (comparison before and after the storage period) at 5% significance level. RESULTS: The values for average surface roughness were statistically different (p<0.001) among cements at both baseline and after storage. The roughness values of cements in a decreasing order were ZP>RMGIC>C>R (p<0.001). After 15 days, immersion in lactic acid solution resulted in the highest surface roughness for all cements (p<0.05), except for the RC group (p>0.05). Compared to the current threshold (0.2 µm) related to biofilm accumulation, both RC and C remained below the threshold, even after acidic challenge by immersion in lactic acid solution. CONCLUSIONS: Storage time and immersion in lactic acid solution increased the surface roughness of the majority of the tested cements. RC presented the smoothest surface and it was not influenced by storage conditions.
  • Radiopacity evaluation of Portland and MTA-based cements by digital radiographic system Original Articles

    Borges, Alvaro Henrique; Pedro, Fabio Luiz Miranda; Semanoff-Segundo, Alex; Miranda, Carlos Eduardo Saraiva; Pécora, Jesus Djalma; Cruz Filho, Antônio Miranda

    Resumo em Inglês:

    OBJECTIVE: The aim of the present study was to evaluate the radiopacity of Portland and MTA-based cements using the Digora TM digital radiographic system. MATERIAL AND METHODS: The performed tests followed specification number 57 from the American National Standard Institute/American Dental Association (2000) for endodontic sealing materials. The materials were placed in 5 acrylic plates, especially designed for this experiment, along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The set was radiographed at a 30 cm focus-object distance and with 0.2 s exposure time. After the radiographs were taken, the optical laser readings of radiographs were performed by Digora TM system. Five radiographic density readings were performed for each studied material and for each step of the aluminum scale. RESULTS: White ProRoot MTA (155.99±8.04), gray ProRoot MTA (155.96±16.30) and MTA BIO (143.13±16.94) presented higher radiopacity values (p<0.05), while white non-structural Portland (119.76±22.34), gray Portland (109.71±4.90) and white structural Portland (99.59±12.88) presented lower radiopacity values (p<0.05). CONCLUSIONS: It was concluded that MTA-based cements were the only materials presenting radiopacity within the ANSI/ADA specifications.
  • Effects of silica coating and silane surface conditioning on the bond strength of rebonded metal and ceramic brackets Original Articles

    Atsü, Saadet; Çatalbaş, Bülent; Gelgör, Ibrahim Erhan

    Resumo em Inglês:

    OBJECTIVE: The aim of this study was to evaluate the effects of tribochemical silica coating and silane surface conditioning on the bond strength of rebonded metal and ceramic brackets. MATERIAL AND METHODS: Twenty debonded metal and 20 debonded ceramic brackets were randomly assigned to receive one of the following surface treatments (n=10 for each group): (1) sandblasting (control); (2) tribochemical silica coating combined with silane. Brackets were rebonded to the enamel surface on the labial and lingual sides of premolars with a light-polymerized resin composite. All specimens were stored in distilled water for 1 week and then thermocycled (5,000 cycles) between 5-55ºC. Shear bond strength values were measured using a universal testing machine. Student's t-test was used to compare the data (α=0.05). Failure mode was assessed using a stereomicroscope, and the treated and non-treated bracket surfaces were observed by scanning electron microscopy. RESULTS: Rebonded ceramic brackets treated with silica coating followed by silanization had significantly greater bond strength values (17.7±4.4 MPa) than the sandblasting group (2.4±0.8 MPa, P<0.001). No significant difference was observed between the rebonded metal brackets treated with silica coating with silanization (15±3.9 MPa) and the sandblasted brackets (13.6±3.9 MPa). Treated rebonded ceramic specimens primarily exhibited cohesive failure in resin and adhesive failure at the enamel-adhesive interface. CONCLUSIONS: In comparison to sandblasting, silica coating with aluminum trioxide particles followed by silanization resulted in higher bond strengths of rebonded ceramic brackets.
  • Visibility of the mandibular canal on CBCT crosssectional images Original Articles

    Oliveira-Santos, Christiano; Capelozza, Ana Lúcia Álvares; Dezzoti, Mariela Siqueira Gião; Fischer, Cássia Maria; Poleti, Marcelo Lupion; Rubira-Bullen, Izabel Regina Fischer

    Resumo em Inglês:

    The identification of the mandibular canal (MC) is an important prerequisite for surgical procedures involving the posterior mandible. Cone beam computed tomography (CBCT) represents an advance in imaging technology, but distinguishing the MC from surrounding structures may remain a delicate task. OBJECTIVES: The aim of this study was to assess the visibility of the MC in different regions on CBCT cross-sectional images. MATERIAL AND METHODS: CBCT cross-sectional images of 58 patients (116 hemi-mandibles) were analyzed, and the visibility of the MC in different regions was assessed. RESULTS: The MC was clearly visible in 53% of the hemi-mandibles. Difficult and very difficult visualizations were registered in 25% and 22% of the hemi-mandibles, respectively. The visibility of the MC on distal regions was superior when compared to regions closer to the mental foramen. No differences were found between edentulous and tooth-bearing areas. CONCLUSIONS: The MC presents an overall satisfactory visibility on CBCT cross-sectional images in most cases. However, the discrimination of the canal from its surrounds becomes less obvious towards the mental foramen region when cross-sectional images are individually analyzed.
  • Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests Original Articles

    Miyashiro, Mariane; Suedam, Valdey; Moretti Neto, Rafael Tobias; Ferreira, Paulo Martins; Rubo, José Henrique

    Resumo em Inglês:

    OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
  • Flexural strength of acrylic resin repairs processed by different methods: water bath, microwave energy and chemical polymerization Original Articles

    Arioli Filho, João Neudenir; Butignon, Luís Eduardo; Pereira, Rodrigo de Paula; Lucas, Matheus Guilherme; Mollo Junior, Francisco de Assis

    Resumo em Inglês:

    Denture fractures are common in daily practice, causing inconvenience to the patient and to the dentists. Denture repairs should have adequate strength, dimensional stability and color match, and should be easily and quickly performed as well as relatively inexpensive. OBJECTIVE: The aim of this study was to evaluate the flexural strength of acrylic resin repairs processed by different methods: warm water-bath, microwave energy, and chemical polymerization. MATERIAL AND METHODS: Sixty rectangular specimens (31x10x2.5 mm) were made with warm water-bath acrylic resin (Lucitone 550) and grouped (15 specimens per group) according to the resin type used to make repair procedure: 1) specimens of warm water-bath resin (Lucitone 550) without repair (control group); 2) specimens of warm water-bath resin repaired with warm water-bath; 3) specimens of warm water-bath resin repaired with microwave resin (Acron MC); 4) specimens of warm water-bath resin repaired with autopolymerized acrylic resin (Simplex). Flexural strength was measured with the three-point bending in a universal testing machine (MTS 810 Material Test System) with load cell of 100 kgf under constant speed of 5 mm/min. Data were analyzed statistically by Kruskal-Wallis test (p<0.05). RESULTS: The control group showed the best result (156.04±1.82 MPa). Significant differences were found among repaired specimens and the results were decreasing as follows: group 3 (43.02±2.25 MPa), group 2 (36.21±1.20 MPa) and group 4 (6.74±0.85 MPa). CONCLUSION: All repaired specimens demonstrated lower flexural strength than the control group. Repairs with autopolymerized acrylic resin showed the lowest flexural strength.
  • Characterization of aqueous silver nitrate solutions for leakage tests Original Articles

    Costa, José Ferreira; Siqueira, Walter Luiz; Loguercio, Alessandro Dourado; Reis, Alessandra; Oliveira, Elizabeth de; Alves, Cláudia Maria Coelho; Bauer, José Roberto de Oliveira; Grande, Rosa Helena Miranda

    Resumo em Inglês:

    OBJECTIVE: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated. MATERIAL AND METHODS: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled) and three brands of silver nitrate salt (Merck, Synth or Cennabras) at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h) and concentrations (1, 5, 25, 50%) of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25% or 50% AgNO3 solution and the primary teeth in 5% or 50% AgNO3 solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5%). RESULTS: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9). Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm). In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000). CONCLUSIONS: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO3 solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5% concentration, the solutions were capable of indicating loss of marginal seal in the composite restorations; the 3-step conventional adhesive system had better performance regarding microleakage in enamel on primary and permanent teeth.
  • Experimental alveolitis in rats: microbiological, acute phase response and histometric characterization of delayed alveolar healing Original Articles

    Rodrigues, Moacyr Tadeu Vicente; Cardoso, Camila Lopes; Carvalho, Paulo Sérgio Perri de; Cestari, Tânia Mary; Feres, Magda; Garlet, Gustavo Pompermaier; Ferreira Júnior, Osny

    Resumo em Inglês:

    The pathogenesis of alveolitis is not well known and therefore experimental situations that mimic some features of this disease should be developed. OBJECTIVE: In this study, the evolution of the experimentally induced infection in rat sockets is characterized, which leads to clinical signs of suppurative alveolitis with remarkable wound healing disturbs. MATERIAL AND METHODS: Non-infected (Group I) and experimentally infected sockets in Rattus novergicus (Group II) were histometrically evaluated regarding the kinetics of alveolar healing. In addition, the characterization of the present bacteria in inoculation material and the serum levels of C-reactive protein (CRP) were performed. The detected species were Capnocytophaga ochracea, Fusobacterium nucleatum ss nucleatum, Prevotella melaninogenica, Streptococcus anginosus, Treponema socranskii and Streptococcus sanguis. RESULTS: All experimentally infected rats developed suppurative alveolitis, showing higher levels of CRP in comparison to those non-infected ones. Furthermore, infected rats presented a significant delayed wound healing as measured by the histometric analysis (higher persistent polymorphonuclear infiltrate and lower density of newly formed bone). CONCLUSION: These findings indicate that rat sockets with experimentally induced infection produced higher levels of serum CRP, showing the potential of disseminated infection and a disturb in the alveolar repair process in an interesting experimental model for alveolitis studies.
  • Cell block technique as a complementary method in the clinical diagnosis of cyst-like lesions of the jaw Original Articles

    Rivero, Elena Riet Correa; Grando, Liliane Janete; Menegat, Fabíola; Claus, Jonathas Daniel Paggi; Xavier, Felipe Marcelo

    Resumo em Inglês:

    OBJECTIVE: To evaluate the applicability of the cell block technique as a complementary method for presumptive diagnosis in the analysis of cyst-like aspirates from jaw lesions prior to histopathological diagnosis. MATERIAL AND METHODS: The sample was made up of 17 cyst-like jaw lesions. After puncture, the aspirates were centrifuged, fixed in formalin, embedded in paraffin and processed. All lesions were biopsied and submitted to histopathological examination. RESULTS: In 9 cases, the cytopathological analysis using the cell block method showed a predominant presence of erythrocytes, inflammatory cells and few epithelial cells. In the other 8 cases, the cell block technique demonstrated the presence of parakeratin, whose histopathological analysis confirmed the occurrence of keratocystic odontogenic tumors (KOTs). CONCLUSIONS: According to the studied cases, the cell block method was proven to be a simple, fast and low-cost technique to effectively differentiate KOTs from other lesions with similar clinical and radiographic features. The cell block technique comprises cellular preparations useful to determine a clinical diagnosis and help to develop a therapeutic plan for those lesions.
  • Effect of gender, facial dimensions, body mass index and type of functional occlusion on bite force Original Articles

    Koç, Duygu; Dogan, Arife; Bek, Bülent

    Resumo em Inglês:

    OBJECTIVE: Some factors such as gender, age, craniofacial morphology, body structure, occlusal contact patterns may affect the maximum bite force. Thus, the purposes of this study were to determine the mean maximum bite force in individuals with normal occlusion, and to examine the effect of gender, facial dimensions, body mass index (BMI), type of functional occlusion (canine guidance and group function occlusion) and balancing side interferences on it. MATERIAL AND METHODS: Thirty-four individuals aged 19-20 years-old were selected for this study. Maximum bite force was measured with strain-gauge transducers at first molar region. Facial dimensions were defined by standardized frontal photographs as follows: anterior total facial height (ATFH), bizygomathic facial width (BFW) and intergonial width (IGW). BMI was calculated using the equation weight/height². The type of functional occlusion and the balancing side interferences of the subjects were identified by clinical examination. RESULTS: Bite force was found to be significantly higher in men than women (p<0.05). While there was a negative correlation between the bite force and ATFH/BFW, ATFH/IGW ratios in men (p<0.05), women did not show any statistically significant correlation (p>0.05). BMI and bite force correlation was not statistically significant (p>0.05). The average bite force did not differ in subjects with canine guidance or group function occlusion and in the presence of balancing side interferences (p>0.05). CONCLUSIONS: Data suggest that bite force is affected by gender. However, BMI, type of functional occlusion and the presence of balancing side interferences did not exert a meaningful influence on bite force. In addition, transverse facial dimensions showed correlation with bite force in only men.
  • Histologic grading and nucleolar organizer regions in oral squamous cell carcinomas Original Articles

    Hanemann, João Adolfo Costa; Miyazawa, Marta; Souza, Mireile São Geraldo dos Santos

    Resumo em Inglês:

    OBJECTIVE: The purposes of this study were to histologically assess different types of oral squamous cell carcinoma and the silver-binding nucleolar organizer region (AgNOR) morphology in neoplastic cells, as well as to quantify the number of AgNORs in each type of carcinoma in order to relate AgNOR count and histologic grading. MATERIAL AND METHODS: Twenty-eight cases of oral squamous cell carcinoma were divided into 4 groups, namely well-differentiated, moderately differentiated, poorly differentiated, and undifferentiated. For NOR study, 3-µm-thick sections were stained with 50% aqueous silver nitrate solution. The predominant microscopic pattern of NORs was determined. Quantitative analyses of NORs were obtained of all cells present on each histological field using a 0.025 mm² eyepiece graticule. Different histological fields were analyzed until the total number of NORs was 120 cells for each tumor. Kruskall-Wallis test was applied to compare the groups of sample data at a significance level of p=0.05. RESULTS: The mean number of AgNORs per nucleus was 3.20 for the well-differentiated group, 5.33 for the moderately differentiated one, 8.27 for the poorly differentiated one, and 10.08 for the undifferentiated one. AgNOR count was significantly different (p<0.05) among all of the studied groups. CONCLUSION: AgNOR staining technique seems to be a useful diagnostic tool since differences in AgNOR numeric values can be identified in the different types of oral squamous cell carcinoma. This technique is easy to handle and inexpensive, thus justifying its large use in histopathology.
  • Effect of reduced exposure times on the cytotoxicity of resin luting cements cured by high-power led Original Articles

    Ergun, Gulfem; Egilmez, Ferhan; Yilmaz, Sukran

    Resumo em Inglês:

    OBJECTIVE: Applications of resin luting agents and high-power light-emitting diodes (LED) light-curing units (LCUs) have increased considerably over the last few years. However, it is not clear whether the effect of reduced exposure time on cytotoxicity of such products have adequate biocompatibility to meet clinical success. This study aimed at assessing the effect of reduced curing time of five resin luting cements (RLCs) polymerized by high-power LED curing unit on the viability of a cell of L-929 fibroblast cells. MATERIAL AND METHODS: Disc-shaped samples were prepared in polytetrafluoroethylene moulds with cylindrical cavities. The samples were irradiated from the top through the ceramic discs and acetate strips using LED LCU for 20 s (50% of the manufacturer's recommended exposure time) and 40 s (100% exposure time). After curing, the samples were transferred into a culture medium for 24 h. The eluates were obtained and pipetted onto L-929 fibroblast cultures (3x10(4) per well) and incubated for evaluating after 24 h. Measurements were performed by dimethylthiazol diphenyltetrazolium assay. Statistical significance was determined by two-way ANOVA and two independent samples were compared by t-test. RESULTS: Results showed that eluates of most of the materials polymerized for 20 s (except Rely X Unicem and Illusion) reduced to a higher extent cell viability compared to samples of the same materials polymerized for 40 s. Illusion exhibited the least cytotoxicity for 20 s exposure time compared to the control (culture without samples) followed by Rely X Unicem and Rely X ARC (90.81%, 88.90%, and 83.11%, respectively). For Rely X ARC, Duolink and Lute-It 40 s exposure time was better (t=-1.262 p=0,276; t=-9.399 p=0.001; and t=-20.418 p<0.001, respectively). CONCLUSION: The results of this study suggest that reduction of curing time significantly enhances the cytotoxicity of the studied resin cement materials, therefore compromising their clinical performance.
Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil
E-mail: jaos@usp.br