Acessibilidade / Reportar erro

Case 6/2009: 13 years old youngsters with major atrial and ventricular septal defects

CLINICORADIOLOGICAL SESSION

Case 6/2009 - 13 years old youngsters with major atrial and ventricular septal defects

Edmar Atik

Hospital Sírio-Libanês de São Paulo - Brazil

Mailing address Mailing address: Edmar Atik InCor - Av. Dr. Enéas Carvalho de Aguiar, 44 05403-000 - São Paulo, SP - Brasil E-mail: conatik@incor.usp.br

Key words: Heart defects, congenital / surgery; atrial septal defect; ventricular septal defect; heart septal defects.

Clinical data

Heart murmur had been observed upon birth and tiredness on stress, besides palpitations at rest, has been observed by the patient for some years. The patient had taken Digoxin and Furosemide up to 4 years of age. Good physical development occurred.

Physical examinations found the patient eupneic, ruddy and with normal pulses. Weight was 71.8 lbs, 4.79 ft of height, heart rate of 82 bpm and blood pressure of 105/65 mm Hg. The aorta was not palpated on the suprasternal notch. There were clear impulsions on the precordium and the left sternal edge was diffusely palpated. The heart sounds were accentuated in intensity. The second heart sound was splitted, with both components of equal intensity. Intense and rude systolic thrill and holosystolic murmur, +++ of intensity, were found in the lower left sternal edge, irradiating to the right sternal edge and to the mitral area. Liver was not palpated.

Electrocardiogram tests (fig.1) showed signs of diastolic left ventricular overload with broad qR complexes in the left precordial leads, R wave of 30 mm in V6 and T positive wave, besides blocking on the left antero-superior division. AQRS was at -40º, AP a +30º and AT at +80º.


Radiographic image

Shows cardiac area highly increased by dilation of left cardiac cavities with double atrium arch to the right and ventricular arch elongated and deviated to the left. Arteries were slightly increased and the medium arch elongated and rectified (Figure 1).

Diagnostic impression

The radiographic image is compatible to congenital acianogenic cardiopathy with high volume overload of left cardiac cavities, followed by an increased pulmonary arterial circulation, such as in conditions involving blood from left to the right, such as in ventricular septal defect.

Differential diagnosis

Due to the higher increase of left cardiac cavities, this image may also lead to a diagnosis of left atrioventricular valve failure. In addition to the acianogenic cardiopathies with obstructed flow to the left of the heart, such as aortic stenosis and aortic coarctation, in cases of left ventricular failure. However, in these abnormal conditions, there will be greater pulmonary venocapillar congestion.

Diagnosis confirmation

Clinical data led to the diagnosis of ventricular septal defect, of repercussion, despite an isolated diastolic left ventricular overload observed in the ECG. Echocardiogram (Figure 2) confirmed this abnormal condition in perimembranous position with extension to the ventricular inlet, with 8 mm of diameter. There was also atrial septal defect with 20 mm of extension. Cardiac cavities measured: Left atrium: 31; Aorta: 24, Right ventricular diastolic diameter: 29, Left ventricular diastolic diameter: 59, Left ventricular sistolic diameter: 38 mm, Shortening ejection fraction: 36%, Ejection fraction: 64%.


Management

Upon the surgery, at extracorporeal circulation of 70', we found atrial septal defect, ostium secundum, of 40 mm and ventricular septal defect of 8 mm, closed with bovine pericardial patch. A good initial evolution was observed and after 5 months from the surgery, no residual defects were observed.

Comments

Unexpected clinical exteriorization associated to major septal defects in which, despite the large atrial septal defect (ASD), almost a single atrium, there was a higher repercussion of the LV volumetric overload caused by the ventricular septal defect (VSD), with no RV potential. This explains the difficulty in finding a diagnosis for the ASD, well-established by echocardiogram examinations, although at an underestimated size. Such exteriorization is uncommon, as the ASD always works as a escape route in the presence of the other defects.

  • Mailing address:
    Edmar Atik
    InCor - Av. Dr. Enéas Carvalho de Aguiar, 44
    05403-000 - São Paulo, SP - Brasil
    E-mail:
  • Publication Dates

    • Publication in this collection
      24 Nov 2009
    • Date of issue
      Oct 2009
    Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
    E-mail: revista@cardiol.br