Savant et ai.(2)2 Savant V, Chavan R, Pushpoth S, Ilango B. Comparing and
intra-/interobserved reliability of anterior chamber depth measurements with Pentacam
and IOLMaster. J Refract Surg. 2008;24(6):615-8., (50) |
Pentacam |
3.21 ± 0.03 |
- |
|
IOLMaster |
3.23 ± 0.03 |
- |
Nemeth G et al.(3)3 Nemeth G, Vajas A, Kolozsvari B, Berta A, Modis L Jr. Anterior chamber
depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound
device. J Cataract Refract Surg. 2006;32(8):1331-5., (42) |
A-Scan |
2.89 ± 0.49 |
- |
|
Pentacam |
2.87 ± 0.40 |
- |
Doors et al.(4)4 Doors M, Cruysberg LP, Berendschot TT, de Brabander J, Verbakel F, Weber
CA, et al. Comparison of central corneal thickness and anterior chamber depth
measurements using three imaging technologies in normal eyes and after phakic
intraocular lens implantation. Graefes Arch Clin Exp Ophthalmol.
2009;247(8):1139-46., (66) |
Orbscan II |
3.25 ± 0.29 |
- |
|
Pentacam |
3.34 ± 0.27 |
- |
|
Visante OCT
|
3.41 ± 0.25 |
- |
Woodmass et al.(5)5 Woodmass J, Rocha G. A comparison of Scheimpflug imaging simulated and
Holladay equivalent keratometry values with partial coherence interferometry
keratometry measurements in phakic eyes. Can J Ophthalmol.
2009;44(6):700-4., (52) |
Pentacam |
3.82 ± 0.41 |
- |
|
IOLMaster |
3.78 ± 0.42 |
- |
Reuland et al.(6)6 Reuland MS, Reuland AJ, Nishi Y, Auffarth GU. Corneal radii and anterior
chamber depth measurements using the IOLMaster versus the Pentacam. J Refract Surg.
2007;23(4):368-73., (82) |
Pentacam |
3.25 ± 0.50 |
- |
|
IOLMaster |
3.20 ± 0.40 |
- |
Lackner et al.(7)7 Lackner B, Schmidinger G, Skorpik C. Validity and repeatability of
anterior chamber depth measurements with Pentacam and Orbscan. Optom Vis Sci.
2005;82(9):858-61., (60) |
Orbscan |
3.23 ± 0.40 |
- |
|
Pentacam |
3.18 ± 0.38 |
- |
Utine et al.(8)8 Utine CA, Altin F, Cakir H, Perente I. Comparison of anterior chamber
depth measurements taken with the Pentacam, Orbscan IIz and IOLMaster in myopic and
emmetropic eyes. Acta Ophthalmol. 2009;87(4):386-91., (42) |
Orbscan II |
3.49 ± 0.30 |
- |
|
Pentacam |
3.54 ± 0.31 |
- |
|
IOLMaster |
3.43 ± 0.29 |
- |
Dinc et al.(9)9 Dinc UA, Gorgun E, Oncel B, Yenerel MN, Alimgil L. Assessment of
anterior chamber depth using Visante optical coherence tomography, slitlamp optical
coherence tomography, IOL Master, Pentacam and Orbscan IIz. Ophthalmologica.
2010;224(6):341-6., (80) |
Orbscan II |
2.80 ± 0.29 |
- |
|
Pentacam |
2.93 ± 0.30 |
- |
|
Visante OCT
|
2.98 ± 0.29 |
- |
|
IOLMaster |
3.33 ± 0.42 |
- |
Elbaz et al.(10)10 Elbaz U, Barkana Y, Gerber Y, Avni I, Zadok D. Comparison of different
techniques of anterior chamber depth and keratometric measurements. Am J Ophthalmol.
2007;143(1):48-53., (22) |
A-Scan |
3.00 ± 0.37 |
- |
|
Pentacam |
3.08 ± 0.38 |
- |
|
IOLMaster |
2.99 ± 0.37 |
- |
Szalai et al.(11)11 Szalai E, Berta A, Nemeth G, Hassan Z, Modis L Jr. Anterior chamber
depth measurements obtained with Pentacam HR® imaging system and conventional A-scan
ultrasound. Ophthalmic Surg Lasers Imaging. 2011;42(2):248-53., (46) |
A-Scan |
3.08 ± 0.43 |
- |
|
Pentacam HR |
2.89 ± 0.41 |
- |
Yazici et al.(12)12 Yazici AT, Bozkurt E, Alagoz C, Alagoz N, Pekel G, Kaya V, et al.
Central corneal thickness, anterior chamber depth, and pupil diameter measurements
using Visante OCT, Orbscan, and Pentacam. J Refract Surg.
2010;26(2):127-33., (100) |
Orbscan |
2.84 ± 0.33 |
- |
|
Pentacam |
2.98 ± 0.33 |
- |
|
Visante OCTe
|
2.94 ± 0.34 |
- |
Salouti et al.(13)13 Salouti R, Nowroozzadeh MH, Zamani M, Ghoreyshi M, Salouti R. Comparison
of anterior chamber depth measurements using Galilei, HR Pentacam, and Orbscan II.
Optometry. 2010;81(1):35-9., (74) |
Orbscan II |
3.54 ± 0.07 |
- |
|
Pentacam HR |
3.25 ± 0.05 |
- |
|
Galilei |
3.22 ± 0.05 |
- |
Hashemi et al.(14)14 Hashemi H, Mehravaran S. Corneal changes after laser refractive surgery
for myopia: comparison of Orbscan II and Pentacam findings. J Cataract Refract Surg.
2007;33(5):841-7., (46) |
Orbscan II |
3.10 ± 0.33 |
- |
|
Pentacam |
3.26 ± 0.34 |
- |
Kim et al.(15)15 Kim SW, Sun HJ, Chang JH, Kim EK. Anterior segment measurements using
Pentacam and Orbscan II 1 to 5 years after refractive surgery. J Refract Surg.
2009;25(12):1091-7., (51) |
Orbscan II |
3.09 ± 0.28 |
- |
|
Pentacam |
3.23 ± 0.33 |
- |
O'Donnell et al.(16)16 O'Donnell C, Hartwig A, Radhakrishnan H. Comparison of central corneal
thickness and anterior chamber depth measured using Lenstar LS900, Pentacam, and
Visante AS-OCT. Cornea. 2012;31(9):983-8., (17) |
Pentacam |
2.96 ± 0.32 |
- |
|
Visante OCT |
3.03 ± 0.29 |
- |
|
Lenstar |
2.93 ± 0.30 |
- |
Huang et al.(17)17 Huang J, Pesudovs K, Wen D, Chen S, Wright T, Wang X, et al. Comparison
of anterior segment measurements with rotating Scheimpflug photography and partial
coherence reflectometry. J Cataract Refract Surg. 2011;37(2):341-8., (108) |
Pentacam |
3.78 ± 0.25 |
- |
|
Lenstar |
3.76 ± 0.24 |
- |
Németh et al.(18)18 Nemeth G, Hassan Z, Modis L Jr, Szalai E, Katona K, Berta A. Comparison
of anterior chamber depth measurements conducted with Pentacam HR® and IOLMaster®.
Ophthalmic Surg Lasers Imaging. 2011;42(2):144-7., (83) |
Pentacam HR |
3.01 ± 0.34 |
- |
|
IOLMaster |
2.95 ± 0.32 |
- |
Aramberri et al.(19)19 Aramberri J, Araiz L, García A, Illrramendi I, Olmos J, Oyanarte I, et
al. Dual versus single Scheimpflug camera for anterior segment analysis: Precisions
and agreement. J Cataract Refract Surg. 2012;38(11):1934-49., (35) |
Pentacam HR |
3.04 ± 0.33 |
- |
|
Galilei |
3.14 ± 0.32 |
- |
Salouti et al.(20)20 Salouti R, Nowroozzadeh MH, Zamani M, Ghoreyshi M, Salouti R. Comparison
of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II
systems. Clin Exp Optom. 2009;92(5):429-33., (37) |
Orbscan II |
- |
11.67 ± 0.29 |
|
Galilei |
- |
12.01 ± 0.61 |
|
EyeSys |
- |
12.09 ± 0.87 |
Kim et al.(21)21 Kim SK, Kim HM, Song JS. Comparison of internal anterior chamber
diameter imaging modalities: 35-MHz ultrasound biomicroscopy, Visante optical
coherence tomography, and Pentacam. J Refract Surg.
2010;26(2):120-6., (20) |
Orbscan II |
- |
11.56 ± 0.41 |
|
Pentacam |
- |
11.86 ± 0.45 |
|
Visante OCT |
- |
11.70 ± 0.47 |