Does the type of electrode affect the electromyoneurographic parameters in rats?1 1 Research performed at Laboratory of Experimental Surgery, Universidade do Estado do Pará (UEPA), Belem-PA, Brazil.

Abstract

Purpose:

To evaluate if the type of electrode (needle vs. surface) affects the electromyoneurography parameters in rats.

Methods:

Twenty male rats were anesthetized, then compound muscle action potential were recorded using a Neuropack S1 MEB- 9400©. All animals were submitted to two electroneuromyography analysis: first with surface electrode and then by needle electrode. We evaluated the latency, amplitude, duration and area of the negative peak of the gastrocnemius and cranial tibial muscles.

Results:

There were no significant differences between the groups in the mean of duration, latency, amplitude or area of the negative peak in gastrocnemius and cranial tibial muscles.

Conclusion:

The type of electrode does not affect the electroneuromyography parameters.

Key words:
Neurophysiology; Neural Conduction; Experimental Development; Rats