Acessibilidade / Reportar erro

Cutaneous sensibility assesment in hemodialysis- related carpal tunnel syndrome

OBJECTIVE: Describe the use of the PSSD (Pressure specified sensory Device) for the diagnosis of carpal tunnel syndrome. METHODS: The PSSD is a tool that incorporates a pressure transducer with two prongs, linked to a computer capable of measuring the cutaneous pressure thresholds. The patients were divided in two groups: Group 1- patients neither with superior limb neuropathy nor renal insufficiency. Group 2- patients with carpal tunnel syndrome related to hemodialysis. Group 2 - patients with carpal tunnel syndrome but no renal insufficiency. RESULTS: The results showed, for two of the four parameters measured, that the group 2 had more benefits for the diagnosis of carpal tunnel syndrome than group 3. CONCLUSION: The PSSD is useful as a diagnostic tool in hemodialysis-related carpal tunnel syndrome Level of Evidence: Level II, development of diagnostic.

Carpal tunnel syndrome; Renal dialysis; Nerve compression syndromes


ATHA EDITORA Rua: Machado Bittencourt, 190, 4º andar - Vila Mariana - São Paulo Capital - CEP 04044-000, Telefone: 55-11-5087-9502 - São Paulo - SP - Brazil
E-mail: actaortopedicabrasileira@uol.com.br