Acessibilidade / Reportar erro

Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test

In an attempt to build the evaluation strategies to assess the human eye irritation, a reassessment of some in vitro tests is necessary, particularly concerning the non-irritants, mild and moderate irritants. Thus, the correlations between results obtained from the Draize test with the in vitro methods HET-CAM (Hens Egg Test-Chorion Allantonic Membrane) and RBC haemolysis assay to assess the ocular irritancy potential of 20 eye drops were examined. Parameters such as accuracy (%) and specificity (%) were determined. All results were correlated with RBC correctly with the results obtained in the Draize test. The HET-CAM presented four false-positive results, showing a tendency of data overestimation. Despite the high specificity provided mainly by the RBC, it would be necessary to test a wider range of products representing all the scales of irritation to confirm its ability to be used as a first alternative to test products that could be presumptive non-irritants.

Alternative methods; eye irritation; Draize Test; low-irritant; HET-CAM; RBC


Instituto de Tecnologia do Paraná - Tecpar Rua Prof. Algacyr Munhoz Mader, 3775 - CIC, 81350-010 Curitiba PR Brazil, Tel.: +55 41 3316-3052/3054, Fax: +55 41 3346-2872 - Curitiba - PR - Brazil
E-mail: babt@tecpar.br