Six dogs were submitted to an operation to test the viability of sylicon slab in partial replecement of tracheal wall. These animais were anesthetized and had removed a third part with compatible dimension of the circunference of three tracheal rings at mid cervical region. At this place a sylicon slab was implanted and fixed to the surrounding tracheal cartilage. The dogs were observed during thirty days. At post morten, they were evalueted by gross and microscopic examination. It was detected the tissue replacement and the growing of the epithelium.
implant; sylicon; trachea