Acessibilidade / Reportar erro

Evaluation of electrosurgery and titanium clips for ovarian pedicle haemostasis in video-assisted ovariohysterectomy with two portals in bitches

Eletrocirurgia bipolar e clipes de titânio para hemostasia em pedículos ovarianos durante ovariohisterectomia videoassistida com dois portais em cadelas

ABSTRACT:

This study evaluated the use of bipolar electrosurgery and laparoscopic clipping, and their effects on blood loss and the inflammatory response, during a two portal video-assisted ovariohysterectomy technique (two groups with 10 animals each). Surgical time and blood loss volume were significantly lower in the electrosurgery group. There were no significant changes in haematocrit between groups; however, haematocrit did differ between evaluated times, and decreased 10% from the initial measurement to four hours after the procedure. The inflammatory response was significantly higher throughout the post-surgical period, but without any different clinical signs between the two groups. Both techniques had good application for the two portal video-assisted procedure; however, the bipolar electrosurgery allowed for shorter surgical times, reduced blood loss and a minimal learning curve for the surgeon.

Key words:
laparoscopy; blood tightening; blood loss; packed cell volume; interleukin

Universidade Federal de Santa Maria Universidade Federal de Santa Maria, Centro de Ciências Rurais , 97105-900 Santa Maria RS Brazil , Tel.: +55 55 3220-8698 , Fax: +55 55 3220-8695 - Santa Maria - RS - Brazil
E-mail: cienciarural@mail.ufsm.br