Acessibilidade / Reportar erro

Alignment efficiency and three-dimensional assessment of root resorption after alignment with conventional and copper-nickel-titanium archwires: A randomized controlled trial

ABSTRACT

Objective:

To compare alignment efficiency and root resorption between nickel-titanium (NiTi) and copper-nickel-titanium (CuNiTi) archwires after complete alignment in mandibular anterior region.

Methods:

In this two-arm parallel single-blind randomized controlled trial, forty-four patients with Class I malocclusion with mandibular anterior crowding were recruited form orthodontic clinic of All India Institute of Medical Sciences (Jodhpur, India). Patients were randomly allocated into NiTi and CuNiTi groups, with a 1:1 allocation. Alignment was performed using 0.014-in, 0.016-in, 0.018-in, 0.019x0.025-in archwire sequence in the respective groups, which terminated in 0.019 x 0.025-in stainless-steel working archwire. The primary outcome was alignment efficiency, measured on study models from baseline (T0) to the first, second, third, fourth and fifth-month (T5). Secondary outcome was root resorption, measured from CBCT scans taken at T0 and T5. Mixed-factorial ANOVA was used to compare Little’s Irregularity Index (LII). For assessing the proportion of patients with complete alignment at the end of each month, Kaplan-Meier survival curve was built and time to treatment completion was compared between groups using log rank test. Paired t-test was used to assess external apical root resorption (EARR) within groups, whereas independent t-test was used to evaluate LII and EARR between the groups.

Results:

Twenty-two patients were recruited in each group. One patient was lost to follow-up in the CuNiTi group. No statistically significant differences were observed in alignment efficiency between the groups (p>0.05). Intergroup comparison revealed that the changes in root measurement in three-dimensions were not statistically significant (p>0.05), except for mandibular right central incisor, which showed increased resorption at root apex in NiTi group (p<0.01).

Conclusion:

The two alignment archwires showed similar rate of alignment at all time points. Root resorption measurement did not differ between the NiTi and CuNiTi groups, except for the mandibular right central incisor, which showed more resorption in NiTi group.

Keywords:
Alignment; Root resorption; Fixed orthodontic appliances; Orthodontic wires; CBCT

Dental Press International Av. Luís Teixeira Mendes, 2712 , 87015-001 - Maringá - PR, Tel: (55 44) 3033-9818 - Maringá - PR - Brazil
E-mail: artigos@dentalpress.com.br