Open-access Vicarious contrast media excretion: the bloody effusion Doppelgänger

A 3-year-old boy was admitted to the hospital with decompensated congenital heart disease, hypotension (serum lactate: 100mg/dL), and acute renal failure (serum creatinine: 3.54mg/dL). Hemodynamic angiography was performed to assess cardiac pressures with a volume of 120 mL at a rate of 15 mL/s of iodinated contrast. Approximately 4 h later, the patient underwent a chest computed tomography (CT) scan using a 320-section scanner without intravenous injection of iodinated contrast or use of general anesthesia. Vicariant contrast excretion was observed in virtually all the body tissues (Figure 1). Ten days later, after further evaluation using chest CT, these findings were no longer observed (Figure 1).

Figure 1
Non-contrasted chest and head computed tomography (CT) scan of a 3-year-old male, showing vicariant contrast media excretion 4 h after an angiographic evaluation (A, B, and C). (A) Spontaneous hyperdensity in the subcutaneous tissue, muscles, joints, including synovial fluid (white arrowheads) and cerebrospinal fluid (red dashed circle) at the cervicothoracic junction. (B) Spontaneous hyperdensity of the pleura (orange arrowheads), and pericardium (blue arrowheads) at the inferior third of the chest. (C) Spontaneously hyperdense ascites (yellow arrowheads) at the thoracoabdominal transition. Ten days later, these findings were no longer observed in a contrast-enhanced chest CT scan (D, E, and F)

The use of contrast media is well-established as a critical component in diagnostic and interventional radiology. Among the various types, iodine-based contrast media are most commonly used for diagnostic and therapeutic purposes, including CT evaluation, interventional procedures, and hemodynamics. These agents may be administered through several routes: intravenous, rectal, oral, or directly into the fistulous tract or biliary tree.

Typically, iodinated contrast media are primarily excreted through renal filtration, with minimal excretion via the biliary and gastrointestinal tracts.(1,2) Under normal physiological conditions, virtually no contrast medium is detected a few hours after administration, even at high doses. However, persistent contrast medium may be detected in diverse body tissues hours after its intravenous administration.

Understanding the vicarious excretion of iodinated contrast medium is crucial for accurate radiological interpretation and clinical decision-making. This often-overlooked phenomenon can significantly affect imaging results, potentially mimicking serious conditions such as abdominal hemorrhage, hemothorax, hemopericardium, and intracranial hemorrhage. This mimicry can lead to misdiagnosis and inappropriate treatment. Radiologists across all subspecialties must be aware of this phenomenon to differentiate it from genuine hemorrhagic manifestations and ensure accurate diagnosis and optimal patient care.

REFERENCES

  • 1 Lautin EM, Friedman AC. Vicarious excretion of contrast media. JAMA. 1982;247(11):1608-10.
  • 2 Thurtle D, Petchey W. Vicarious contrast excretion causing intraluminal colonic contrast on abdominal CT. Postgrad Med J. 2016;92(1091):562.

Edited by

  • Associate Editor:
    Carlos Vicente Serrano Jr. Instituto do Coração (InCor), Hospital das Clínica, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil ORCID: https://orcid.org/0000-0002-9171-1224

Publication Dates

  • Publication in this collection
    24 Oct 2025
  • Date of issue
    2025

History

  • Received
    09 Sept 2024
  • Accepted
    16 June 2025
location_on
Instituto Israelita de Ensino e Pesquisa Albert Einstein Avenida Albert Einstein, 627/701 , 05651-901 São Paulo - SP, Tel.: (55 11) 2151 0904 - São Paulo - SP - Brazil
E-mail: revista@einstein.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Reportar erro