Abstract
Most conventional sewage treatment systems are not able to fully remove micropollutants found in sewage. Thus, the simultaneous degradation of 11 pharmaceuticals identified in the effluent of a sewage treatment plant in Southern Brazil was herein investigated through advanced oxidation processes based on ozonation, ultraviolet radiation and hydrogen peroxide. For detection, samples were prepared through solid-phase extraction and pharmaceuticals were identified through ultra-high performance liquid chromatography tandem mass spectrometry. Active ingredients such as ciprofloxacin, oxytetracycline, paracetamol, sulfamethoxazole and trimethoprim had their concentrations increased for degradation analysis purposes. Trials were carried out on a bench at room temperature and neutral pH, with aliquots collected at 7.5 and 15 minutes. Two ozone doses (0.5 and 0.9 mg per mg of dissolved organic carbon), and combinations of the lowest ozone dose with photolysis (254 nm) and with 25 mg.L−1 of hydrogen peroxide were evaluated. Pharmaceuticals mineralization efficiency was assessed in a total organic carbon analyzer. The process combining ozone, hydrogen peroxide and ultraviolet radiation was the most efficient in the degradation of all pharmaceuticals detected in this study, since it enabled reducing oxytetracycline by 89.32%, caffeine by 96.79%, trimethoprim by 97.40%, ciprofloxacin by 97.75%, sulfamethoxazole by 99.79%, paracetamol by 99.96%, and clindamycin, ofloxacin, sulfadiazine, sulfathiazole and tylosin by 100%. This process also recorded the highest mineralization rate (60.52%), fact that confirmed the potential to decrease persistent pharmaceuticals found in conventional sewage treatment systems.
Keywords:
sewage treatmen; micropollutant; ozonatio; hydrogen peroxid; ultraviolet radiation
Resumo
A maioria dos sistemas convencionais de tratamento de esgoto não é capaz de remover totalmente os micropoluentes presentes no esgoto. Assim, a degradação simultânea de 11 fármacos, detectados no efluente de uma estação de tratamento de esgoto no Sul do Brasil, foi investigada por meio de processos oxidativos avançados baseados em ozonização, radiação ultravioleta e peróxido de hidrogênio. Para detecção, as amostras foram preparadas por extração em fase sólida e os fármacos foram identificados por cromatografia líquida de ultra eficiência acoplada à espectrometria de massa em tandem. Ingredientes ativos como ciprofloxacina, oxitetraciclina, paracetamol, sulfametoxazol e trimetoprima tiveram suas concentrações aumentadas para análise de degradação. Os ensaios foram realizados em bancada a temperatura ambiente e pH neutro, com alíquotas coletadas aos 7,5 e 15 minutos. Duas doses de ozônio (0,5 e 0,9 mg por mg de carbono orgânico dissolvido) e combinações da menor dose de ozônio com fotólise (254 nm) e com 25 mg.L−1 de peróxido de hidrogênio foram avaliadas. A eficiência da mineralização dos fármacos foi verificada em um analisador de carbono orgânico total. O processo combinando de ozônio, peróxido de hidrogênio e radiação ultravioleta foi o mais eficiente na degradação de todos os fármacos detectados neste estudo, pois permitiu reduzir a oxitetraciclina em 89,32%, a cafeína em 96,79%, o trimetoprim em 97,40%, a ciprofloxacina em 97,75%, o sulfametoxazol em 99,79%, o paracetamol em 99,96% e a clindamicina, a ofloxacina, a sulfadiazina, o sulfatiazol e a tilosina em 100%. Esse processo também registrou a maior taxa de mineralização (60,52%), confirmando o potencial de redução de fármacos persistentes encontrados em sistemas convencionais de tratamento de esgoto.
Palavras-chave
tratamento de esgoto; micropoluentes; ozonização; peróxido de hidrogênio; radiação ultravioleta
INTRODUCTION
Thousands of tons of pharmaceuticals are annually consumed to prevent and treat human and animal diseases, mainly in Asian, American, and European countries (JIANG et al., 2014JIANG, Y.; LI, M.; GUO, C.; AN, D.; XU, J.; ZHANG, Y.; XI, B. Distribution and ecological risk of antibiotics in a typical effluent-receiving river (Wangyang River) in north China. Chemosphere, v. 112, p. 267-274, 2014. https://doi.org/10.1016/j.chemosphere.2014.04.075
https://doi.org/10.1016/j.chemosphere.20...
; HU et al., 2018HU, J.; ZHOU, J.; ZHOU, S.; WU, P.; TSANG, Y.F. Occurrence and fate of antibiotics in a wastewater treatment plant and their biological effects on receiving waters in Guizhou. Process Safety and Environmental Protection, v.113, p. 483-490, 2018. https://doi.org/10.1016/j.psep.2017.12.003
https://doi.org/10.1016/j.psep.2017.12.0...
; MARTINI et al., 2018MARTINI, J.; ORGE, C.A.; FARIA, J.L.; PEREIRA, M.F.R.; SOARES, O.S.G.P. Sulfamethoxazole degradation by combination of advanced oxidation processes. Journal of Environmental Chemical Engineering, v. 6, n. 4, p. 4054-4060, 2018. https://doi.org/10.1016/j.jece.2018.05.047
https://doi.org/10.1016/j.jece.2018.05.0...
). However, most of these pharmaceuticals present high stability (VERLICCHI; AL AUKIDY; ZAMBELLO, 2012VERLICCHI, P.; AL AUKIDY, M.; ZAMBELLO, E. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment-A review. Science of the Total Environment, v. 429, p. 123-155, 2012. https://doi.org/10.1016/j.scitotenv.2012.04.028
https://doi.org/10.1016/j.scitotenv.2012...
) and low assimilation in the body, since 50 to 90% of the administered doses are excreted as active substance in patients’ urine (MARTINI et al., 2018; MONDAL; SAHA; SINHA, 2018MONDAL, S.K.; SAHA, A.K.; SINHA, A. Removal of ciprofloxacin using modified advanced oxidation processes: Kinetics, pathways and process optimization. Journal of Cleaner Production, v. 171, p. 1203-1214, 2018. https://doi.org/10.1016/j.jclepro.2017.10.091
https://doi.org/10.1016/j.jclepro.2017.1...
). Thus, pharmaceuticals typically soluble in water arrive at sewage treatment plants (STP), where most of their compounds are not fully removed through conventional biological processes (BALAKRISHNA et al., 2017BALAKRISHNA, K.; RATH, A.; PRAVEENKUMARREDDY, Y.; GURUGE, K.S.; SUBEDI, B. A review of the occurrence of pharmaceuticals and personal care products in Indian water bodies. Ecotoxicology and Environmental Safety, v. 137, p. 113-120, 2017. https://doi.org/10.1016/j.ecoenv.2016.11.014
https://doi.org/10.1016/j.ecoenv.2016.11...
; GRAUMANS et al., 2022GRAUMANS, M.H.F.; VAN HOVE, H.; SCHIRRIS, T.; HOEBEN, W.F.L.M.; VAN DAEL, M.F.P.; ANZION, R.B.M.; RUSSEL, F.G.M.; SCHEEPERS, P.T.J. Determination of cytotoxicity following oxidative treatment of pharmaceutical residues in wastewater. Chemosphere, v. 303, 2022. https://doi.org/10.1016/j.chemosphere.2022.135022
https://doi.org/10.1016/j.chemosphere.20...
; KRISHNAN et al., 2021KRISHNAN, R.Y.; MANIKANDAN, S.; SUBBAYA, R.; BIRUNTHA, M.; KARMEGAM, N. Removal of emerging micropollutants originating from pharmaceuticals and personal care products (PPCPs) in water and wastewater by advanced oxidation processes: A review. Environmental Technology & Innovation, v. 23, 2021.; LOZANO et al., 2022LOZANO, I.; PÉREZ-GUZMÁN, C.J.; MORA, A.; MAHLKNECHT, J.; AGUILAR, C.L.; CERVANTES-AVILÉS, P. Pharmaceuticals and personal care products in water streams: Occurrence, detection, and removal by electrochemical advanced oxidation processes. Science of The Total Environment, v. 827, 2022. https://doi.org/10.1016/j.scitotenv.2022.154348
https://doi.org/10.1016/j.scitotenv.2022...
; LUO et al., 2014LUO, Y. L.; GUO, W.; NGO, H.H.; NGHIEM, L.D.; HAI, F.I.; ZHANG, J.; LIANG, S.; WANG, X.C. A review on the occurrence of micropollutants in the aquatic environment and their fate and removal during wastewater treatment. Science of the Total Environment, v. 473-474, p. 619-641, 2014. https://doi.org/10.1016/j.scitotenv.2013.12.065
https://doi.org/10.1016/j.scitotenv.2013...
; KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
; MARSON et al. 2022MARSON, E.O.; PANIAGUA, C.E.S.; GOMES JÚNIOR, O.; GONÇALVES, B.R.; SILVA, V.M.; RICARDO, I.A.; STARLING, M.C.V.M.; AMORIM, C.C.; TROVÓ, A.G. A review toward contaminants of emerging concern in Brazil: Occurrence, impact and their degradation by advanced oxidation process in aquatic matrices. Science of The Total Environment, v .836, 2022. https://doi.org/10.1016/j.scitotenv.2022.155605
https://doi.org/10.1016/j.scitotenv.2022...
; VERLICCHI; AL AUKIDY; ZAMBELLO, 2012VERLICCHI, P.; AL AUKIDY, M.; ZAMBELLO, E. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment-A review. Science of the Total Environment, v. 429, p. 123-155, 2012. https://doi.org/10.1016/j.scitotenv.2012.04.028
https://doi.org/10.1016/j.scitotenv.2012...
; TAOUFIK et al., 2021TAOUFIK, N.; BOUMYA, W.; ACHAK, M.; SILLANPÄÄ, M.; BARKA, N. Comparative overview of advanced oxidation processes and biological approaches for the removal pharmaceuticals. Journal of Environmental Management, v. 288, 2021. https://doi.org/10.1016/j.jenvman.2021.112404
https://doi.org/10.1016/j.jenvman.2021.1...
). Consequently, recalcitrant substances such as antibiotics are released into the environment along with the final effluent (MARSON et al., 2022MARSON, E.O.; PANIAGUA, C.E.S.; GOMES JÚNIOR, O.; GONÇALVES, B.R.; SILVA, V.M.; RICARDO, I.A.; STARLING, M.C.V.M.; AMORIM, C.C.; TROVÓ, A.G. A review toward contaminants of emerging concern in Brazil: Occurrence, impact and their degradation by advanced oxidation process in aquatic matrices. Science of The Total Environment, v .836, 2022. https://doi.org/10.1016/j.scitotenv.2022.155605
https://doi.org/10.1016/j.scitotenv.2022...
), fact that leads to (eco)toxicological effects on several non-target organisms, mainly on the aquatic ones (LIU et al., 2018LIU, L.; WU, W.; ZHANG, J.; LV, P.; XU, L.; YAN, Y. Progress of research on the toxicology of antibiotic pollution in aquatic organisms. Acta Ecologica Sinica, v. 38, n. 1, p. 36-41, 2018. https://doi.org/10.1016/j.chnaes.2018.01.006
https://doi.org/10.1016/j.chnaes.2018.01...
; LOZANO et al., 2022). In addition, these substances can be biotransformed, bioaccumulated and biomagnified at different trophic levels (MONDAL; SAHA; SINHA, 2018).
Therefore, it is necessary pursuing alternatives to enable the removal, or the maximum reduction, of several recalcitrant pharmaceuticals from municipal and industrial wastewaters. Luo et al. (2014) and Marson et al. (2022MARSON, E.O.; PANIAGUA, C.E.S.; GOMES JÚNIOR, O.; GONÇALVES, B.R.; SILVA, V.M.; RICARDO, I.A.; STARLING, M.C.V.M.; AMORIM, C.C.; TROVÓ, A.G. A review toward contaminants of emerging concern in Brazil: Occurrence, impact and their degradation by advanced oxidation process in aquatic matrices. Science of The Total Environment, v .836, 2022. https://doi.org/10.1016/j.scitotenv.2022.155605
https://doi.org/10.1016/j.scitotenv.2022...
) reported the use of tertiary systems based on advanced oxidation processes (AOP), which stood out for the ease of implementation at real scale, and for the slight economic advantage, in comparison to the use of filtration membranes and activated carbon adsorption (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
). In addition, the individual application of oxidizing agents such as ozone (O3), hydrogen peroxide (H2O2) and ultraviolet radiation (UV), mainly as disinfection systems to replace chlorinated agents in treatment plants, has increased (ARAÚJO et al., 2016ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
https://doi.org/10.4136/ambi-agua.1862...
). Accordingly, there has been increase in the number of studies about the use of AOP to enable the simultaneous removal of pharmaceuticals from sanitary effluents (AFONSO-OLIVARES et al., 2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
; DE LA CRUZ et al., 2013DE LA CRUZ, N.; ESQUIUS, L.; GRANDJEAN, D.; MAGNET, A.; TUNGLER, A.; ALENCASTRO, L.F.; PULGARÍN, C. Degradation of emergent contaminants by UV, UV/H2O2 and neutral photo-Fenton at pilot scale in a domestic wastewater treatment plant. Water Research, v. 47, n. 15, p. 5836-5845, 2013. https://doi.org/10.1016/j.watres.2013.07.005
https://doi.org/10.1016/j.watres.2013.07...
; HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
; KRISHNAN et al., 2021KRISHNAN, R.Y.; MANIKANDAN, S.; SUBBAYA, R.; BIRUNTHA, M.; KARMEGAM, N. Removal of emerging micropollutants originating from pharmaceuticals and personal care products (PPCPs) in water and wastewater by advanced oxidation processes: A review. Environmental Technology & Innovation, v. 23, 2021.; ZIMMERMANN et al., 2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
), besides the ones addressing the individual degradation of compounds (MARTINI et al., 2018; MONDAL; SAHA; SINHA, 2018) or the reduced number of selected active ingredients (ALHARBI et al., 2017ALHARBI, S.K.; KANG, J.; NGHIEM, L.D.; VAN DE MERWE, J.P.; LEUSCH, F.D.L.; PRICE, W.E. Photolysis and UV/H2O2 of diclofenac, sulfamethoxazole, carbamazepine, andtrimethoprim: Identification of their major degradation products by ESI–LC–MS and assessment of the toxicity of reaction mixtures. Process Safety and Environmental Protection, v. 112, p. 222-234, 2017. https://doi.org/10.1016/j.psep.2017.07.015
https://doi.org/10.1016/j.psep.2017.07.0...
; KATSOYIANNIS; CANONICA; VON GUNTEN, 2011KATSOYIANNIS, I.A.; CANONICA, S.; VON GUNTEN, U. Efficiency and energy requirements for the transformation of organic micropollutants by ozone, O3/H2O2 and UV/H2O2. Water Research, v.45, p. 3811-3822, 2011. https://doi.org/10.1016/j.watres.2011.04.038
https://doi.org/10.1016/j.watres.2011.04...
).
Besides conventional processes, AOP are a promising technique that can be used to remove a wide range of organic micropollutants from wastewater (ALHARBI et al., 2017; BRILLAS; MARTÍNEZ-HUITLE, 2015BRILLAS, E.; MARTÍNEZ-HUITLE, C.A. Decontamination of wastewaters containing synthetic organic dyes by electrochemical methods: An updated review. Applied Catalysis B: Environmental, v. 166-167, p. 603-643, 2015. https://doi.org/10.1016/j.apcatb.2014.11.016
https://doi.org/10.1016/j.apcatb.2014.11...
; TAOUFIK et al., 2021TAOUFIK, N.; BOUMYA, W.; ACHAK, M.; SILLANPÄÄ, M.; BARKA, N. Comparative overview of advanced oxidation processes and biological approaches for the removal pharmaceuticals. Journal of Environmental Management, v. 288, 2021. https://doi.org/10.1016/j.jenvman.2021.112404
https://doi.org/10.1016/j.jenvman.2021.1...
) due to the formation of highly-reactive species with high oxidizing power, such as the radical known as hydroxyl (OH•) (E° = 2.80 V), which can enable the mineralization, or transformation, of several organic compounds into simpler substances (ARAÚJO et al., 2016ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
https://doi.org/10.4136/ambi-agua.1862...
).
O3 is an extremely strong oxidant (E° = 2.07 V) that can be widely applied to disinfect water, as well as to remove taste, odor, and color from it (KATSOYIANNIS; CANONICA; VON GUNTEN, 2011; LIM et al., 2022). The transformation of organic compounds through O3 application can happen in direct or indirect ways. The molecular ozone reacts to organic compounds in the direct mechanism via direct oxidation, whereas, in the indirect mechanism, there is the formation of OH• radicals, which react faster to organic compounds than O3 (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; MAHMOUD; FREIRE, 2007MAHMOUD, A.; FREIRE, R.S. New methods for enhancing ozone efficiency on contaminated water treatment. Química Nova, v. 30, n. 1, p. 198-205, 2007. https://doi.org/10.1590/S0100-40422007000100032
https://doi.org/10.1590/S0100-4042200700...
; MARTINI et al., 2018). Studies have described more than 70% reduction, and even the full removal, of some soluble pharmaceuticals that have reacted to ozone within the first 20 reaction min, at doses ranging from 0.5 to 0.9 mgO3 mgDOC−1 (dissolved organic carbon) (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
; ZIMMERMANN et al., 2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
). However, drug removal through O3 application can be limited by the short lifespan of the oxidizing agent and by compound adhesion to organic matter particles (KANAKARAJU; GLASS; OELGEMÖLLER, 2018KANAKARAJU, D.; GLASS, B. D.; OELGEMÖLLER, M. Advanced oxidation process-mediated removal of pharmaceuticals from water: A review. Journal of Environmental Management, v. 219, p. 189-207, 2018. https://doi.org/10.1016/j.jenvman.2018.04.103
https://doi.org/10.1016/j.jenvman.2018.0...
). On the other hand, the combination between O3 and UV-C radiation (200 to 360 nm) enabled O3 photolysis and generated OH• radicals that potentiated the degradation, and mineralization, of organic compounds. Non-reactive OH• radicals, in their turn, recombined to each other and generated H2O2 (ARAÚJO et al., 2016ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
https://doi.org/10.4136/ambi-agua.1862...
; MARTINI et al., 2018).
Although H2O2 is a strong oxidant (Eº = 1.78 V), its oxidation potential is lower than that of O3 and OH•. Thus, reactions based on H2O2 are not efficient in degrading organic compounds due to their very slow decomposition in oxidizing radicals and to the strong influence of parameters such as temperature and pH (MARTINI et al., 2018). Therefore, H2O2 is often used in combination with UV-C radiation (less than 280 nm), which breaks the O-O bond of the peroxide molecule and produces OH• (ALHARBI et al., 2017; ARAÚJO et al., 2016ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
https://doi.org/10.4136/ambi-agua.1862...
; GRAUMANS et al., 2022). It is also possible making other combinations, such as H2O2 and O3, in which H2O2 works as homogeneous catalyst by accelerating ozone degradation to form non-selective OH• radicals (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; LIM et al., 2022).
Photolysis based on UV-C radiation (254 nm) is widely used to disinfect drinking water, besides being increasingly applied to slightly-turbid wastewater (ALHARBI et al., 2017). Although some pharmaceuticals are susceptible to degradation even at typical doses used in disinfection processes (AFONSO-OLIVARES et al., 2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
), degradation is achieved when there is radiation enough to break the chemical bonds of the compounds, i.e., when the photon energy exceeds the bond energy (MARTINI et al., 2018). Drug degradation through UV radiation can happen both through direct and indirect ways. In the first case, molecules absorb radiation photons and break, whereas, in the second case, there is the generation of strong reactive species, such as OH•, from compounds naturally found in solution (ALHARBI et al., 2017; FATTA-KASSINOS; VAZQUEZ; KÜMMERER, 2011FATTA-KASSINOS, D.; VASQUEZ, M.I.; KÜMMERER, K. Transformation products of pharmaceuticals in surface waters and wastewater formed during photolysis and advanced oxidation processes − Degradation, elucidation of byproducts and assessment of their biological potency. Chemosphere, v. 85, n. 5, p. 693-709, 2011. https://doi.org/10.1016/j.chemosphere.2011.06.082
https://doi.org/10.1016/j.chemosphere.20...
).
Thus, it is recommended combining two, or more, AOP to form strong oxidants (OH•) (MARSON et al., 2022MARSON, E.O.; PANIAGUA, C.E.S.; GOMES JÚNIOR, O.; GONÇALVES, B.R.; SILVA, V.M.; RICARDO, I.A.; STARLING, M.C.V.M.; AMORIM, C.C.; TROVÓ, A.G. A review toward contaminants of emerging concern in Brazil: Occurrence, impact and their degradation by advanced oxidation process in aquatic matrices. Science of The Total Environment, v .836, 2022. https://doi.org/10.1016/j.scitotenv.2022.155605
https://doi.org/10.1016/j.scitotenv.2022...
; MARTINI et al., 2018; TAOUFIK et al., 2021TAOUFIK, N.; BOUMYA, W.; ACHAK, M.; SILLANPÄÄ, M.; BARKA, N. Comparative overview of advanced oxidation processes and biological approaches for the removal pharmaceuticals. Journal of Environmental Management, v. 288, 2021. https://doi.org/10.1016/j.jenvman.2021.112404
https://doi.org/10.1016/j.jenvman.2021.1...
), which can reduce the generation of toxic by-products during degradation processes (AFONSO-OLIVARES et al., 2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
; ALHARBI et al., 2017; ARAÚJO et al., 2016ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
https://doi.org/10.4136/ambi-agua.1862...
; GRAUMANS et al., 2022). Therefore, the aim of the current study was to investigate the efficiency of simultaneous degradation, and mineralization, of pharmaceuticals in sanitary sewage post-treatment based on advanced oxidation processes comprising O3, UV radiation and photochemical associations O3/UV, H2O2/UV and O3/H2O2/UV.
MATERIALS AND METHODS
Origin of the studied sanitary effluent
Post-treatment trials were performed with sanitary sewage from a sewage treatment plant (STP) located in the metropolitan region of Porto Alegre city, Rio Grande do Sul state (RS), Brazil. The mentioned system operates at mean flow 2,250 ± 250 L∙s−1 and serves approximately 600 thousand people. It comprises mechanical screening, de-sanding and biological treatment units in Upflow Anaerobic Sludge Blanket (UASB) reactors, as well as activated sludge, in the process called Unitank: cyclic operations in the aeration stage, which are followed by sedimentation and disinfection with H2O2.
Treated effluent samples were collected in the STP emissary in April 2018, from 7 a.m. to 12 p.m.; effluent aliquots were collected every hour until reaching 40 L volume. Non-toxic high-density polyethylene (HDPE) bottles were used, previously sanitized and rinsed with the samples at collection time. A 1-L aliquot of sample was collected in amber bottle to enable determining pharmaceuticals and hormones; the bottle was stored under refrigeration (± 4°C) for further analysis.
Analytical procedures
Detection of compounds in effluent samples
Effluent samples were subjected to tests focused on detecting 44 compounds (Table 1 supplementary material), including human and veterinary prescription pharmaceuticals and hormones, at the Pesticide Residue Analysis Laboratory (LARP) of the Federal University of Santa Maria (UFSM), RS, Brazil.
Concentrations of pharmaceuticals found through ultra-high-performance liquid chromatography coupled to tandem mass spectrometry in the sewage sample before and after the increase of active principles for post-treatment trials.
Solid analyte standards with purity ranging from 95.0 to 99.6% were purchased from the German companies Dr. Ehrenstorfer and Witega. The individual standard solution of each analyte was prepared at concentration 1,000 mg∙L−1 in acetonitrile. Next, a solution containing the mixture of all pharmaceuticals at concentration 10 mg∙L−1 in acetonitrile was prepared. These solutions were stored in amber bottles at 5 °C.
Sample preparation
Sample preparation was based on solid phase extraction (SPE), adapted from Jank et al. (2014JANK, L.; HOFF, R.B.; COSTA, F.J.; PIZZOLATO, T.M. Simultaneous determination of eight antibiotics from distinct classes insurface and wastewater samples by solid-phase extraction and high-performance liquid chromatography–electrospray ionization mass spectrometry. International Journal of Environmental Analytical Chemistry, v. 94, n. 10, p. 1013-1037, 2014. https://doi.org/10.1080/03067319.2014.914184
https://doi.org/10.1080/03067319.2014.91...
), using Strata®-X cartridges: 100 mL of sample were percolated and eluted with the acidified mixture of MeOH:MeCN (1:1, v/v) solvents. Next, samples were diluted twice in ultrapure water and analyzed through ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) by Waters (USA). This process used liquid chromatograph; triple quadrupole MS detector, model Xevo TQ; electrospray ionization source; Acquity UPLC® BEH C18 analytical column (50 × 2.1 mm, 1.7 μm) by Waters (USA); and MassLynx 4.1 data acquisition system (Waters, USA). Two linear gradients were used to determine pharmaceuticals and hormones, at run time 4 and 3 minutes, respectively, flow rate 0.250 mL∙min−1 and injection volume 10 μL (for both). The mobile phase adopted for pharmaceuticals, except for caffeine and paracetamol, comprised (A) water: methanol (98:2, v/v) and (B) methanol, both containing 5 mmol∙L−1 ammonium formate and 0.1% formic acid (v/v); whereas the one adopted for hormones, caffeine and paracetamol comprised (A) 0.05% (v/v) aqueous ammonium hydroxide solution and (B) methanol. Analytes were quantified and identified by monitoring the selected reactions.
Sample characterization
Effluent samples were also subjected to physicochemical and microbiological characterization, before and after the post-treatment tests were applied to the most efficient process. The analyzed parameters were total organic carbon (TOC), total nitrogen (NTotal), alkalinity, turbidity, suspended solids (SS), temperature, pH, chemical oxygen demand (COD), biochemical oxygen demand (BOD5), total phosphorus (PTotal) and thermotolerant coliforms, according to analytical methods set by the Standard Methods for the Examination of Water and Wastewater (APHA; AWWA; WEF, 2012AMERICAN PUBLIC HEALTH ASSOCIATION (APHA); AMERICAN WATER WORKS ASSOCIATION (AWWA); WATER ENVIRONMENT FEDERATION (WEF). Standard Methods for the Examination of Water and Wastewater. 22th ed. Washington, DC: APHA, AWWA, WEF, 2012. 1360 p.).
The drug mineralization degree was determined through TOC removal in a high-sensitivity Shimadzu analyzer (model TOC-L CPH, TNM-L), based on the non-purgeable organic carbon (NPOC) fraction method. The mentioned equipment was also used to determine the dissolved organic carbon (DOC), which corresponded to the organic matter fraction permeated in a 0.45 μm filter, based on the difference between total and inorganic carbon (ZIMMERMANN et al., 2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
) and NT.
Experimental procedure
After the effluent analysis, active ingredients such as ciprofloxacin, oxytetracycline, paracetamol, sulfamethoxazole and trimethoprim were added to the sample at concentrations higher than the ones predicted to have no effect (predicted no-effect concentrations — PNEC) on the most sensitive species, in order to enable the AOP trials. These compounds were chosen because they recorded the highest persistence and/or incidence rates in the herein investigated sample, as reported in other studies (DINH et al., 2017DINH, Q.T.; MOREAU-GUIGON, E.; LABADIE, P.; ALLIOT, F.; TEIL, M.J.; BLANCHARD, M.; CHEVREUIL, M. Occurrence of antibiotics in rural catchments. Chemosphere, v. 168, p. 483-490, 2017. https://doi.org/10.1016/j.chemosphere.2016.10.106
https://doi.org/10.1016/j.chemosphere.20...
; HU et al., 2018; MARTÍN et al., 2012MARTÍN, J.; CAMACHO-MUÑOZ, D.; SANTOS, J.L.; APARICIO, I.; ALONSO, E. Occurrence of pharmaceutical compounds in wastewater and sludge from wastewater treatment plants: removal and ecotoxicological impact of wastewater discharges and sludge disposal. Journal of Hazardous Materials, v. 239-240, p. 40-47, 2012. https://doi.org/10.1016/j.jhazmat.2012.04.068
https://doi.org/10.1016/j.jhazmat.2012.0...
). In this way, the objective was to find a concentration capable of enabling a better comparison between different processes.
Drug degradation trials based on O3, UV radiation, and on combinations such as O3/UV, H2O2/UV, and O3/H2O2/UV, were performed at laboratory bench scale, room temperature 20.6 ± 0.3°C and pH 6.94 ± 0.02 (adjusted with 0.1 N H2SO4). Reaction time was set at 15 minutes, since drug degradation through AOP can happen in the early stage of the process (KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
; RIVAS; BELTRÁN; ENCINAS, 2012RIVAS, F.J.; BELTRÁN, F.J.; ENCINAS, A. Removal of emergent contaminants: Integration of ozone and photocatalysis. Journal of Environmental Management, v. 100, p. 10-15, 2012. https://doi.org/10.1016/j.jenvman.2012.01.025
https://doi.org/10.1016/j.jenvman.2012.0...
; ZIMMERMANN et al., 2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
), whereas long-exposure periods would hardly be economically viable at large scale. Samples were not filtered to allow simulating real conditions.
Degradation trial based on ozonation
The dissolved organic matter (measured in DOC) is the main matrix used to determine O3 consumption in wastewater, regardless of the drug concentration (Hansen et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
). Therefore, the herein adopted O3 dose was determined based on the DOC concentration of the effluent, as explained by Zimmermann et al. (2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
), Knopp et al. (2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
) and Hansen et al. (2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
), and on the production capacity of the generating plant, which was evaluated according to the indirect titration iodometric method recommended by the International Ozone Association (APHA; AWWA; WEF, 2012).
Trials were performed with two O3 doses: the first (the lowest one) was 0.5 mgO3∙mgDOC−1, whereas the second (the highest one) was 0.9 mgO3∙mgDOC−1. O3 was generated in a Purizonium compact plant with production capacity of 600 mgO3∙h−1, based on atmospheric air suction, filtration in silica gel and electric discharge (Corona effect). The equipment outlet ducting was connected to a porous stone placed at the bottom of a 1000 mL gas scrubber-type reaction flask. The output of the flask was connected to another 500 mL gas scrubber filled with 2% potassium iodide solution in order to transform residual ozone into oxygen (APHA; AWWA; WEF, 2012). The degradation test was carried out in batch for 15 minutes; 100 mL aliquots were collected after 7.5 min, and at the end of the reaction process, for chromatographic, TOC, COD, turbidity, and pH analyses.
Degradation trial based on ultraviolet radiation
The photolysis-based degradation experiment was performed in a cylindrical photoreactor with 76 mm diameter, 480 mm length, and 2.0 L useful volume. The photoreactor was built in PVC and equipped in the center with a 15 W mercury OSRAM low UV-C pressure (λ = 253.7 nm) transparent quartz tube lamp; the effluent was placed in direct contact with the lamp, under slow agitation, to enable uniform exposure. The lamp was turned on 30 minutes before the photoreactor was powered on, in order to achieve maximum radiation. Next, the effluent was exposed to UV radiation for 15 minutes and aliquots were collected after 7.5 minutes, and at the end of the reaction process, under the same conditions adopted in the previous experiment.
Degradation trial based on ozonation and ultraviolet radiation
The ozonation experiment combined with UV radiation adopted the ozone dose 0.5 mgO3∙mgDOC−1 in the photolysis test reactor, which was also used in the other UV experiments, under the same lamp preheating conditions. The porous stone of the O3 generating station was placed inside the photoreactor to enable this experiment. After the system was filled with the effluent, O3 started being injected in it in order to homogenize the solution and to enable uniform O3/effluent/UV contact. The same residual ozone destruction procedures in 2% potassium iodide solution were adopted at the reactor outlet. This experiment followed the sample collection pattern and the time adopted in the other experiments.
Degradation trial based on hydrogen peroxide and ultraviolet radiation
This experiment comprised the addition of 25 mgH2O2∙L−1 (35%, Merck) effluent to the photoreactor, based on the study by Afonso-Olivares et al. (2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
). The effluent was placed in direct contact with the lamp, under slow agitation, to enable uniform exposure. Again, the lamp was turned on 30 minutes in advance and aliquots were collected after 7.5 and 15 reaction minutes for drug degradation, TOC, COD, turbidity, and pH analyses.
Degradation trial based on ozonation, hydrogen peroxide and ultraviolet radiation
This experiment was carried out under the same conditions adopted in the previous one; however, it evaluated the influence of the combination added with O3. The effluent containing 25 mgH2O2∙L−1 (35%, Merck) was added to the system, after the hose with the porous stone was inserted in the photoreactor. The experiment adopted the dose 0.5 mgO3∙mgDOC−1, which enabled homogenization of, and uniformity in, the contact between the sample and the lamp. This system, like the others, was operated in batch; aliquots were collected halfway the reaction process, and at the end of it, to enable drug degradation, TOC, COD, turbidity, and pH analyses.
The photoreactor was washed between tests with running deionized water and homogenized with the sample to be post-treated.
The use of the lowest O3 dosage (0.5 mgO3∙mgDOC−1) in experiments in which there was association with other agents (O3/UV and O3/H2O2/UV) was based on preliminary results of removal of different active principles by the isolated action of photolysis (UV) and photoperoxidation (H2O2/UV). Associated with H2O2/UV, O3 starts to act, mainly, as an aid in the degradation of compounds that present greater reactivity with molecular ozone (LIM et al., 2022) in relation to OH• radicals. Still, with lower dosages of oxidizing agents, an attempt was made to minimize the possible generation of toxic intermediate metabolites, showed in the study developed by Bisognin et al. (2020BISOGNIN, R.P.; WOLFF, D.B.; CARISSIMI, E.; PRESTES, O.D.; ZANELLA, R.; STORCK, T.R.; CLASSEN, B. Potential environmental toxicity of sewage effluent with pharmaceuticals. Ecotoxicology, v. 29, p. 1315-1326, 2020. https://doi.org/10.1007/s10646-020-02264-7
https://doi.org/10.1007/s10646-020-02264...
), as well as cost minimization with a view to future application on a large scale, without compromising the reduction of target active ingredients.
Analysis of advanced oxidation processes efficiency in degrading pharmaceuticals
The efficiency in degrading pharmaceuticals is shown in Equation 1 — wherein E corresponds to efficiency (%), C0 and C represent the initial and final concentration of interest, respectively —, which was used to evaluate drug removal/reduction efficiency, TOC, and other effluent parameters.
Chemical reaction kinetics principles were also taken into consideration in the herein adopted drug removal processes (ABARGUES et al., 2018ABARGUES, M.R.; GIMÉNEZ, J.B.; FERRER, J.; BOUZAS, A.; SECO, A. Endocrine disrupter compounds removal in wastewater using microalgae: Degradation kinetics assessment. Chemical Engineering Journal, v. 334, p. 313-321, 2018. https://doi.org/10.1016/j.cej.2017.09.187
https://doi.org/10.1016/j.cej.2017.09.18...
); linear regression was used to determine the rate constants (K), correlation coefficient (R2) and the half-life time (t1/2) of the pharmaceuticals in each process.
The degradation experiments were replicated in two additional times to statistically validate the processes. This validation was performed through ANOVA test based on the TOC concentration of the effluent at the beginning, and at the end, of the reaction. Results were subjected to Tukey test in order to compare the means (p ≤ 0.05), in compliance with procedures available in the R statistical package (R CORE TEAM, 2016R CORE TEAM. R: A language environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria, 2016. Available at: https://r-project.org/. Accessed on: May 3, 2018.
https://r-project.org/...
).
RESULTS AND DISCUSSION
Thirteen pharmaceuticals out of the 44 evaluated compounds were found in the raw effluent of the herein investigated STP, 11 of them remained in the effluent after the treatment (Table 1), thus indicating the need of developing complementary techniques to enable their full removal or reduction. Table 1 also shows the concentration of active ingredients added to the effluent due to their persistence and incidence to enable better comparing the post-treatment processes. Enrofloxacin and metronidazole, which were found in the raw effluent at concentrations 0.037 and 0.023 μg∙L−1, respectively, were the only pharmaceuticals fully removed through the conventional system.
Degradation tests were conducted through different AOP based on the knowledge about drug concentrations, DOC (6.31 mg∙L−1) and TOC (10.69 mg∙L−1) in the effluent. Results are shown in Figure 1.
Drug degradation in sanitary sewage based on advanced oxidative processes: O3 (0.5 and 0.9 mgO3∙mgDOC−1); UV (15 W); O3/UV (0.5 mgO3∙mgDOC−1/UV 15 W); H2O2/UV (25 mgH2O2∙L−1/UV 15 W); O3/H2O2/UV (0.5 mgO3∙mgDOC−1/ 25 mgH2O2∙L−1UV 15 W).
The herein evaluated AOP recorded different drug removal performances, except for antibiotics such as ofloxacin, sulfadiazine and sulfathiazole, which were no longer found in the early reaction minutes, regardless of the degradation process. The degradation of these antibiotics may have been favored by low ofloxacin and sulfadiazine concentrations, which ranged from 0.025 to 0.078 μg∙L−1, respectively. However, although clindamycin was found at low concentration (0.071 μg∙L−1) in the effluent, it was only removed through the H2O2/UV and O3/H2O2/UV processes. This drug was more sensitive to H2O2 in combination with UV radiation, since O3 and UV radiation, either in separate or in combination, did not enable eliminating the active principle due to its strongly complex molecular structure. Three other antibiotics — trimethoprim, ciprofloxacin, and sulfamethoxazole — also presented degradation rates lower than the ones recorded for other pharmaceuticals in processes evaluating the use of O3, in separate. This outcome may have been influenced by the oxidizing agent dose, since Martini et al. (2018) reported that sulfamethoxazole was more easily removed through a single ozonation, after 15 reaction minutes, although with the application of 50 mgO3∙L−1, i.e., 8.8 times the maximum application reported in the current study. The dose of 0.5 mgO3∙mgDOC−1 did not enable full tylosin removal from the effluent, since the structural carbon, hydrogen and oxygen chain of this antibiotic is higher than that of the other herein evaluated compounds.
Sulfamethoxazole showed sensitivity to UV radiation and recorded high degradation rates in the first minutes of the process; however, the highest concentration reductions were observed in the O3/UV and O3/H2O2/UV processes — 99.57 and 99.79%, respectively (Figure 2).
Total ion chromatogram generated for sulfamethoxazole after effluent treatment based on different advanced oxidation processes.
On the other hand, clindamycin, oxytetracycline and trimethoprim were the antibiotics least affected by photolysis. This finding shows the limitation in the exclusive use of UV radiation in drug degradation processes, since sulfamethoxazole is co-administered with trimethoprim at ratio of 5:1 (LIN et al., 2018LIN, H.; LI, H.; CHEN, L.; LI, L.; YIN, L.; LEE, H.; YANG, Z. Mass loading and emission of thirty-seven pharmaceuticals in a typical municipal wastewater treatment plant in Hunan Province, Southern China. Ecotoxicology and Environmental Safety, v. 147, p. 530-536, 2018. https://doi:10.1016/j.ecoenv.2017.08.052
https://doi.org/10.1016/j.ecoenv.2017.08...
). UV radiation, in its turn, allowed reducing ciprofloxacin concentrations by more than 50% after the evaluation period. It is worth emphasizing that the O3/UV combination enhanced the degradation of the other pharmaceuticals in comparison to the action of O3 and UV radiation, in separate. It happened because some active principles presented higher reactivity to molecular ozone (KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
), whereas others reacted better to the oxidation triggered by OH• radicals formed by O3 photolysis, as reported by Rivas, Beltrán and Encinas (2012).
Overall, drug degradation was intensified in the H2O2/UV process, which enabled greater concentration reductions and celerity. Only oxytetracycline and trimethoprim were less sensitive to this combination, mainly due to the low influence of UV radiation on the mentioned antibiotics. However, the increased degradation rates in the H2O2/UV process can be explained by OH• formation in the photochemical method. Such formation was triggered by the direct H2O2 oxidation caused by UV light, since oxidation led to molecule O-O bond breakage, which is also known as homolytic peroxide bond cleavage (ARAÚJO et al., 2016ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
https://doi.org/10.4136/ambi-agua.1862...
; GRAUMANS et al., 2022).
The action of OH• radicals formed in the H2O2/UV process, in association with the direct O3 reaction to organic molecules via electrophilic addition, and with the indirect O3 reaction in the formation of radical species (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; MAHMOUD; FREIRE, 2007MAHMOUD, A.; FREIRE, R.S. New methods for enhancing ozone efficiency on contaminated water treatment. Química Nova, v. 30, n. 1, p. 198-205, 2007. https://doi.org/10.1590/S0100-40422007000100032
https://doi.org/10.1590/S0100-4042200700...
), enabled the highest drug removal rates in the early reaction minute of the O3/H2O2/UV treatment. According to Kanakaraju, Glass and Oelgemöller (2018), most hybrid and integrated techniques perform better than single treatments. However, despite the significant reduction in the concentration of all pharmaceuticals, oxytetracycline and trimethoprim showed increased resistance to degradation at the end of the reaction process.
The drug removal efficiency shown in Figure 3 clearly indicates different responses of active principles to the evaluated oxidizing agents, fact that reinforces the importance of conducting studies with real samples in order to define the process capable of presenting the best results.
Removal of the investigated pharmaceuticals through advanced oxidative processes: O3; UV (15 W); O3/UV (0.5 mgO3∙mgDOC−1/UV 15 W); H2O2/UV (25 mgH2O2∙L−1/UV 15 W); O3/H2O2/UV (0.5 mgO3∙mgDOC−1/ 25 mgH2O2∙L−1/UV 15 W).
The high performance of the O3/H2O2/UV process was attributed to extensive OH• formation, due to photozonation. These radicals were amplified by H2O2 addition (MARTINI et al., 2018). This process was mentioned by Jiang, Zhou, and Sharma (2013JIANG, J.-Q.; ZHOU, Z.; SHARMA, V.K. Occurrence, transportation, monitoring and treatment of emerging micro-pollutants in waste water — A review from global views. Microchemical Journal, v. 110, p. 292-300, 2013. https://doi.org/10.1016/j.microc.2013.04.014
https://doi.org/10.1016/j.microc.2013.04...
) as one of the main methods adopted for OH• radical generation purposes. Antibiotics such as clindamycin, ofloxacin, sulfadiazine, sulfathiazole, and tylosin were 100% removed from the effluent; they were followed by almost full degradation of paracetamol (99.96%), sulfamethoxazole (99.79%), ciprofloxacin (97.75%), trimethoprim (97.40%) and caffeine (96.79%), whereas oxytetracycline was more persistent, although it recorded high reduction rate (89.32%). Drug removal rates higher than 90% were recorded in the early reaction minute, fact that indicated the potential of the process to degrade the target micropollutants, although studies focused on drug removal from wastewater based on the O3/H2O2/UV combination are scarce in the literature (MARTINI et al., 2018).
Caffeine and ciprofloxacin were more sensitive to H2O2/UV processes. This outcome indicated oxidation, mainly due to OH• radicals, although caffeine was also sensitive to UV radiation. Similar to the most efficient process, caffeine, and ciprofloxacin removal higher than 90% was recorded in the early reaction minute, when there was greater OH• availability. Results reported in the current study are similar to the ones described by Afonso-Olivares et al. (2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
), who adopted the same H2O2 concentration (25 mg∙L−1) in association with UV. The mentioned authors recorded high caffeine (87%), ofloxacin (79%), ciprofloxacin, and sulfamethoxazole (> 99%) removal rates, whereas the current study recorded 94.10, 100, 93.86, and 99.57% removal rates for the same pharmaceuticals, respectively. Mondal, Saha, and Sinha (2018) reported full ciprofloxacin removal (C0 = 10 mg∙L−1) from the effluent, after 40 minutes of UV/H2O2 reaction (100 mmol∙L−1). Graumans et al. (2022) also report cirpofloxacin removal (> 99%) with the H2O2/UV process.
On the other hand, oxytetracycline reduction was lower in the H2O2/UV process than in the O3 and O3/UV processes. This outcome indicated greater degradation of the active principle by molecular ozone action, in comparison to the increased drug removal efficiency in the O3/H2O2/UV process.
Results showed that the degradation efficiency of some drugs increased as the O3 dose increased, which was also observed in H2O2 concentrations (5 to 25 mg∙L−1) evaluated by Afonso-Olivares et al. (2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
), and in the ones (1 to 100 mmol∙L−1) evaluated by Mondal, Saha, and Sinha (2018). Ciprofloxacin removal rates increased from 27.50 to 62.40% as the O3 dose increased from 0.5 to 0.9 mgO3∙mgDOC−1, whereas clindamycin removal rates increased from 6.58 to 40.85%, oxytetracycline removal rates increased from 15.94 to 88.40%, paracetamol removal rates increased from 80.91 to 99.34%, tylosin removal rates increased from 60.78 to 100%, and trimethoprim removal rates increased from 11.60 to 36.86%. Other studies also reported increased drug degradation efficiency as the O3 dose increased (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; KATSOYIANNIS; CANONICA; VON GUNTEN, 2011; KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
; LEE et al., 2013LEE, Y.; GERRITY, D.; LEE, M.; BOGEAT, A.E.; SALHI, E.; GAMAGE, S.; TRENHOLM, R.A.; WERT, E.C; SNYDER, S.A; VON GUNTEN, U. Prediction of Micropollutant Elimination during Ozonation of Municipal Wastewater Effluents: Use of Kinetic and Water Specific Information. Environmental Science & Technology, v. 47, p. 5872-5881, 2013. https://doi.org/10.1021/es400781r
https://doi.org/10.1021/es400781r...
; ZIMMERMANN et al., 2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
).
The lowest removal efficiency rate was recorded for clindamycin at 0.5 mgO3∙mgDOC−1 (6.58%), due to influence of the complex molecular structure of the compound. However, UV radiation was also poorly effective in removing clindamycin from the effluent, since it reduced the initial concentration of this antibiotic by 11.27%. Similar behavior was recorded for oxytetracycline (12.40%) and trimethoprim (9.11%) reduction under UV light. Alharbi et al. (2017) reported trimethoprim reduction by 58.2% after 1 hour of exposure to UV radiation, which indicated low antibiotic reactivity to the process.
However, the application of UV radiation for 15 minutes enabled reducing ciprofloxacin concentrations by 54.73% in the present study; this outcome is very close to the 60% removal rate reported by Mondal, Saha, and Sinha (2018), who also applied direct photolysis to the same antibiotic, although for 120 minutes. Photolysis enabled reducing by more than 75% the concentrations of the other pharmaceuticals evaluated in the current study; this value was higher than the ones Afonso-Olivares et al. (2016AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2. Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
https://doi.org/10.1016/j.jphotochem.201...
) recorded for caffeine (10.99%) and ofloxacin (71%) after 45 reaction minutes; equal to the one recorded for sulfamethoxazole (> 99%); and lower to the ones recorded for ciprofloxacin (> 99%) and trimethoprim (18.80%). It is worth emphasizing that the mentioned authors adopted the ratio of 6.25 L sample per lamp (14 W), whereas the current study adopted the ratio of 2 L sample per lamp (15 W), although it used higher concentrations of pharmaceuticals.
The full drug degradation in wastewater is often compromised by the presence of organic matter and nitrogen, which interfere in the action of OH• radicals over target micropollutants (GRAUMANS et al., 2022; KATSOYIANNIS; CANONICA; VON GUNTEN, 2011). Accordingly, the reactivity of the effluent organic matter (EfOM) composition to hydroxyl was investigated by Dong, Mezyk, and Rosario-Ortiz (2010), who recorded reduced OH• radicals as the molecular weight of the organic fraction increased. Thus, the higher the residual EfOM concentration, the greater the reduction of OH• radicals. This outcome may explain the incomplete degradation of some pharmaceuticals at the end of the process, since the herein evaluated sanitary sewage had 42.94 mg∙L−1 of COD, 10.69 mg∙L−1 of TOC and 27.43 mg∙L−1 of NTotal. Therefore, higher O3 and H2O2 concentrations, as well as extended reaction times and analyses conducted under reduced organic matter and nitrogen concentrations, should be adopted in future studies. Furthermore, in certain cases, discharged metabolites are transformed back into their pristine structure and become bioactive again (GRAUMANS et al., 2022).
Kinetic analysis of the degradation
Overall, the degradation of antibiotics and other pharmaceuticals often follows first-order kinetics (KANAKARAJU; GLASS; OELGEMÖLLER, 2018KANAKARAJU, D.; GLASS, B. D.; OELGEMÖLLER, M. Advanced oxidation process-mediated removal of pharmaceuticals from water: A review. Journal of Environmental Management, v. 219, p. 189-207, 2018. https://doi.org/10.1016/j.jenvman.2018.04.103
https://doi.org/10.1016/j.jenvman.2018.0...
). However, degradation conditions enabled by AOP can induce second-order kinetics (JIANG; ZHOU; SHARMA, 2013; KATSOYIANNIS; CANONICA; VON GUNTEN, 2011; MONDAL; SAHA; SINHA, 2018), as recorded for most pharmaceuticals exposed to O3 (0.9 mg), UV radiation and O3/UV combination in the current study. When these processes were analyzed in separate, only paracetamol degradation followed first-order kinetics, whereas the two processes combining the use of H2O2 presented similar behavior towards degradation kinetics, whose parameters are shown in Table 2.
Kinetic parameters of drug degradation reactions, based on the different herein investigated advanced oxidative processes: order of reactions; kinetic constant; correlation coefficient and half-life time.
Based on the degradation kinetics of the herein investigated pharmaceuticals, it was possible seeing that the highest rate constant (k) values were recorded for the combination O3/H2O2/UV that, consequently, enabled the shortest half-life time to the active principles. This behavior reinforces the claims that drug removal happens in the early stage of the reaction, and that the process efficiency depends on operating conditions and on oxidizing agent concentrations. Other studies adopted neutral pH and recorded increased drug degradation at the beginning of reactions (HANSEN et al., 2016HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
https://doi.org/10.1016/j.cej.2016.01.02...
; KNOPP et al., 2016KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
https://doi.org/10.1016/j.watres.2016.04...
; MAHMOUD; FREIRE, 2007MAHMOUD, A.; FREIRE, R.S. New methods for enhancing ozone efficiency on contaminated water treatment. Química Nova, v. 30, n. 1, p. 198-205, 2007. https://doi.org/10.1590/S0100-40422007000100032
https://doi.org/10.1590/S0100-4042200700...
; RIVAS; BELTRÁN; ENCINAS, 2012RIVAS, F.J.; BELTRÁN, F.J.; ENCINAS, A. Removal of emergent contaminants: Integration of ozone and photocatalysis. Journal of Environmental Management, v. 100, p. 10-15, 2012. https://doi.org/10.1016/j.jenvman.2012.01.025
https://doi.org/10.1016/j.jenvman.2012.0...
; ZIMMERMANN et al., 2011ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
https://doi.org/10.1016/j.watres.2010.07...
) triggered either by molecular ozone or by OH• radicals formed in O3/UV, H2O2/UV, and O3/H2O2/UV combinations. According to Jiang et al. (2010JIANG, J.L.; YUE, X.A.; CHEN, Q.F.; GAO, Z. Determination of ozonization reaction rate constants of aromatic pollutants and QSAR study. Bulletin of Environmental Contamination and Toxicology, v. 85, p. 568-572, 2010. https://doi.org/10.1007/s00128-010-0127-5
https://doi.org/10.1007/s00128-010-0127-...
), Rivas, Beltrán and Encinas (2012) and Lim et al. (2022LIM, S.; SHI, J.L.; VON GUNTEN, U.; McCURRY, D.L. Ozonation of organic compounds in water and wastewater: A critical review. Water Research, v. 213, 2022. https://doi.org/10.1016/j.watres.2022.118053
https://doi.org/10.1016/j.watres.2022.11...
), O3 and UV radiation reacted instantaneously to several pharmaceuticals and to other micropollutants through second-order kinetics, as observed in the current study. It is worth emphasizing that H2O2-combined processes recorded first- and second-order degradation kinetics for the same pharmaceuticals.
Overall, oxytetracycline and trimethoprim were more resistant to degradation, whereas UV radiation enabled the lowest rate constants, except for sulfamethoxazole, which was highly sensitive to the UV light. This outcome confirmed the information about photolysis-based sulfamethoxazole degradation described by Alharbi et al. (2017). However, the mentioned authors reported increased solution toxicity, which indicated the formation of photolytic products that were more toxic than the original ones, fact that was not reported in the H2O2/UV combination. Luo et al. (2018LUO, S.; WEI, Z.; SPINNEY, R.; ZHANG, Z.; DIONYSIOU, D.D.; GAO, L.; CHAI, L.; WANG, D.; XIAO, R. UV direct photolysis of sulfamethoxazole and ibuprofen: an experimental and modelling study. Journal of Hazardous Materials, v. 343, p. 132-139, 2018. https://doi.org/10.1016/j.jhazmat.2017.09.019
https://doi.org/10.1016/j.jhazmat.2017.0...
) described pseudo first-order kinetics under direct photolysis (254 nm) applied to sulfamethoxazole, both at pH 3 and at 7.55, unlike results observed in the current study, although degradations depend on several factors such as photoreactor and effluent characteristics. This information was corroborated by Kanakaraju, Glass and Oelgemöller (2018), who pointed out that degradation reaction orders change from study to study and that there is no clear consensus about this aspect.
Mondal, Saha, and Sinha (2018) also found second-order kinetics in ciprofloxacin degradation in UV and H2O2/UV processes, thus corroborating the herein reported results. The mentioned authors also reported that the modified photo-Fenton was the most efficient process, since it enabled full antibiotic degradation (10 mg∙L−1) after 30 minutes. Zimmermamm et al. (2011) reported that micropollutant oxidations often follow second-order kinetics, mainly when there is O3 action and combined conditions capable of favoring OH• formation. This kinetics is maintained as long as the concentration of micropollutants does not significantly affect the stability of the oxidant. Therefore, kinetic results recorded in the current study suggested the joint action of direct (due to the action of O3 and UV radiation) and indirect (due to OH• formation) degradation.
Mineralization and chemical oxygen demand removal analysis
Drug mineralization through AOP was evaluated based on TOC reduction. COD reduction was also evaluated, as shown in Figure 4.
Efficiency in reducing total organic carbon and chemical oxygen demand through advanced oxidative processes. Note: TOC: total organic carbon; COD: chemical oxygen demand. Data represent the mean and standard error (±). Lowercase letters in TOC data and uppercase letters in COD data indicate significant difference between treatments (p ≤ 0.05).
The highest TOC reduction in the effluent was observed in the O3/H2O2/UV process, which presented mean concentration reduction of 60.52%, whereas the lowest reduction (15.28%) was found in the UV process, although it was higher than the 9.6% reduction reported by De la Cruz et al. (2013) in sanitary sewage photolysis based on 22 micropollutants. The O3-based treatment at the lowest evaluated dose (0.5 mgO3∙mgDOC−1) did not present TOC reduction statistically different from that of the UV treatment, because, according to Lim et al. (2022), complete mineralization of micropollutants is normally not achieved during ozonation. The other treatments presented statistically significant difference from one another; the best results were observed in combination processes. The limited TOC reduction may have been caused by residual organic matter found in the sewage, since it minimizes the action of OH• radicals in the pharmaceuticals, as already reported by Dong, Mezyk, and Rosario-Ortiz (2010) and by Katsoyiannis, Canonica, and Von Gunten (2011). TOC reduction results reported in the current study were higher than that described by Mondal, Saha, and Sinha (2018) in UV-based ciprofloxacin degradation (4.04%), similar to the one obtained by the same authors in the H2O2/UV process (35.41%) after 40 minutes of reaction, and to the maximum rate recorded (59.99%) in the modified photo-Fenton treatment.
Márquez et al. (2014MÁRQUEZ, G.; RODRÍGUEZ, E.M.; MALDONADO, M.I.; ÁLVAREZ, P.M. Integration of ozone and solar TiO2-photocatalytic oxidation for the degradation of selected pharmaceutical compounds in water and wastewater. Separation and Purification Technology, v. 136, p. 18-26, 2014. https://doi.org/10.1016/j.seppur.2014.08.024
https://doi.org/10.1016/j.seppur.2014.08...
) also found 60% TOC reduction in a mixture of four pharmaceuticals (atenolol, hydrochlorothiazide, ofloxacin, and trimethoprim) in secondary effluent treated with solar photocatalysis and TiO2.
There were no statistically significant differences in COD reduction among O3 (0.9 mg∙mgDOC−1), O3/UV, and O3/H2O2/UV processes. In addition, processes based on the lowest O3 (0.5 mg∙mgDOC−1), UV, and H2O2/UV concentrations showed statistically similar results. However, the O3/H2O2/UV combination was statistically similar to both groups (“A” and “B”). This outcome can be attributed to COD increase caused by H2O2 addition, since H2O2/UV showed the lowest COD reduction rate (8.17%), whereas the maximum reduction rate (30.69%) was observed in the highest O3 dose.
According to Quinõnes et al. (2015QUIÑONES, D.H.; ÁLVAREZ, P.M.; REY, A.; CONTRERAS, S.; BELTRÁN, F.J. Application of solar photocatalytic ozonation for the degradation of emerging contaminants in water in a pilot plant. Chemical Engineering Journal, v. 260, p. 399-410, 2015. https://doi.org/10.1016/j.cej.2014.08.067
https://doi.org/10.1016/j.cej.2014.08.06...
), the synergy index (SI) can determine whether the combined processes are more, or less, efficient in drug mineralization than isolated processes. This index is calculated by dividing the mineralization efficiency value recorded for the combined process by the sum of the mineralization efficiency values recorded for isolated processes. SI higher than 1 means that the combined process has positive effect on efficiency, whereas SI lower than 1 indicates that the combined process is less efficient in drug mineralization. This evaluation was applied to O3/UV processes, such as O3/UV and O3/H2O2/UV, which resulted from O3 and H2O2/UV combination. Both processes recorded synergy indices higher than 1–1.05 and 1.02, respectively; this outcome indicated that these processes were more efficient in drug mineralization than the isolated methods, as already recorded in the drug removal process. However, O3 and H2O2 concentrations, as well as the reaction time, may not have been enough to form the necessary OH• radicals for drug mineralization, as also observed by Martini et al. (2018).
Finally, the O3/H2O2/UV process enabled sanitary sewage disinfection (Escherichia coli elimination), mean turbidity reduction by 13.45%, BOD5 by 15.32%, NTotal by 28.94% and slight pH increase from 6.94 to 7.05. There were no significant changes in SS and PTotal.
CONCLUSIONS
The current study investigated drug degradation in sanitary sewage based on O3, UV, O3/UV, H2O2/UV, and O3/H2O2/UV processes. Results showed that antibiotics such as ofloxacin, sulfadiazine, and sulfathiazole were easily degraded through all evaluated processes, likely due to their low concentrations in the effluent. Tylosin was not fully removed by concentration 0.5 mgO3∙mgDOC−1, only. Clindamycin was 100% removed through H2O2-combined processes. The O3/H2O2/UV process was the most efficient one in reducing the concentration of all pharmaceuticals during the 15 minutes evaluated; oxytetracycline was the most persistent antibiotic (89.32% removal), and it was followed by caffeine (96.79%), trimethoprim (97.40%), ciprofloxacin (97.75%), sulfamethoxazole (99.79%), paracetamol (99.96%), and by the other pharmaceuticals, which recorded 100% removal. Degradations happened in the early stage of the reaction and mostly followed second-order kinetics. UV radiation enabled the lowest drug reductions when it was applied alone, except for sulfamethoxazole, which was more sensitive to the UV light (254 nm).
Despite the high drug removal efficiencies observed in the current study, the herein investigated O3 and H2O2 doses, at 15-minutes reaction time, were not enough to enable drug mineralization, although the highest TOC reduction (60.52%) was found in the O3/H2O2/UV process and the lowest one, in the UV radiation process (15.28%). Therefore, O3/H2O2/UV combination was the most efficient process among the herein studied conditions, since it enabled substantial reduction of drug concentrations in wastewater to values far below the PNEC.
Acknowledgments
Thanks to the Federal University of Santa Maria (UFSM) and to the State University of Rio Grande do Sul (UERGS) for the support and facilities.
REFERENCES
- ABARGUES, M.R.; GIMÉNEZ, J.B.; FERRER, J.; BOUZAS, A.; SECO, A. Endocrine disrupter compounds removal in wastewater using microalgae: Degradation kinetics assessment. Chemical Engineering Journal, v. 334, p. 313-321, 2018. https://doi.org/10.1016/j.cej.2017.09.187
» https://doi.org/10.1016/j.cej.2017.09.187 - AFONSO-OLIVARES, C.; FERNÁNDEZ-RODRÍGUEZ, C.; OJEDA-GONZÁLEZ, R.J.; SOSA-FERRERA, Z.; SANTANA-RODRÍGUEZ, J.J.; DOÑA RODRÍGUEZ, J.M. Estimation of kinetic parameters and UV doses necessary to remove twenty-three pharmaceuticals from pre-treated urban wastewater by UV/H2O2 Journal of Photochemistry and Photobiology A: Chemistry, v. 329, p. 130-138, 2016. https://doi.org/10.1016/j.jphotochem.2016.06.018
» https://doi.org/10.1016/j.jphotochem.2016.06.018 - ALHARBI, S.K.; KANG, J.; NGHIEM, L.D.; VAN DE MERWE, J.P.; LEUSCH, F.D.L.; PRICE, W.E. Photolysis and UV/H2O2 of diclofenac, sulfamethoxazole, carbamazepine, andtrimethoprim: Identification of their major degradation products by ESI–LC–MS and assessment of the toxicity of reaction mixtures. Process Safety and Environmental Protection, v. 112, p. 222-234, 2017. https://doi.org/10.1016/j.psep.2017.07.015
» https://doi.org/10.1016/j.psep.2017.07.015 - AMERICAN PUBLIC HEALTH ASSOCIATION (APHA); AMERICAN WATER WORKS ASSOCIATION (AWWA); WATER ENVIRONMENT FEDERATION (WEF). Standard Methods for the Examination of Water and Wastewater 22th ed. Washington, DC: APHA, AWWA, WEF, 2012. 1360 p.
- ARAÚJO, K.S.; ANTONELLI, R.; GAYDECZKZA, B.; GRANATO, A.C.; MALPASS, G.R.P. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters. Ambiente & Água, v. 11, n. 2, p. 387-401, 2016. https://doi.org/10.4136/ambi-agua.1862
» https://doi.org/10.4136/ambi-agua.1862 - BALAKRISHNA, K.; RATH, A.; PRAVEENKUMARREDDY, Y.; GURUGE, K.S.; SUBEDI, B. A review of the occurrence of pharmaceuticals and personal care products in Indian water bodies. Ecotoxicology and Environmental Safety, v. 137, p. 113-120, 2017. https://doi.org/10.1016/j.ecoenv.2016.11.014
» https://doi.org/10.1016/j.ecoenv.2016.11.014 - BISOGNIN, R.P.; WOLFF, D.B.; CARISSIMI, E.; PRESTES, O.D.; ZANELLA, R.; STORCK, T.R.; CLASSEN, B. Potential environmental toxicity of sewage effluent with pharmaceuticals. Ecotoxicology, v. 29, p. 1315-1326, 2020. https://doi.org/10.1007/s10646-020-02264-7
» https://doi.org/10.1007/s10646-020-02264-7 - BRILLAS, E.; MARTÍNEZ-HUITLE, C.A. Decontamination of wastewaters containing synthetic organic dyes by electrochemical methods: An updated review. Applied Catalysis B: Environmental, v. 166-167, p. 603-643, 2015. https://doi.org/10.1016/j.apcatb.2014.11.016
» https://doi.org/10.1016/j.apcatb.2014.11.016 - DE LA CRUZ, N.; ESQUIUS, L.; GRANDJEAN, D.; MAGNET, A.; TUNGLER, A.; ALENCASTRO, L.F.; PULGARÍN, C. Degradation of emergent contaminants by UV, UV/H2O2 and neutral photo-Fenton at pilot scale in a domestic wastewater treatment plant. Water Research, v. 47, n. 15, p. 5836-5845, 2013. https://doi.org/10.1016/j.watres.2013.07.005
» https://doi.org/10.1016/j.watres.2013.07.005 - DINH, Q.T.; MOREAU-GUIGON, E.; LABADIE, P.; ALLIOT, F.; TEIL, M.J.; BLANCHARD, M.; CHEVREUIL, M. Occurrence of antibiotics in rural catchments. Chemosphere, v. 168, p. 483-490, 2017. https://doi.org/10.1016/j.chemosphere.2016.10.106
» https://doi.org/10.1016/j.chemosphere.2016.10.106 - DONG, M.M.; MEZYK, S.P.; ROSARIO-ORTIZ, F.L. Reactivity of effluent organic matter (EfOM) with hydroxyl radical as a function of molecular weight. Environmental Science & Technology, v. 44, n. 15, p. 5714-5720. https://doi.org/10.1021/es1004736
» https://doi.org/10.1021/es1004736 - FATTA-KASSINOS, D.; VASQUEZ, M.I.; KÜMMERER, K. Transformation products of pharmaceuticals in surface waters and wastewater formed during photolysis and advanced oxidation processes − Degradation, elucidation of byproducts and assessment of their biological potency. Chemosphere, v. 85, n. 5, p. 693-709, 2011. https://doi.org/10.1016/j.chemosphere.2011.06.082
» https://doi.org/10.1016/j.chemosphere.2011.06.082 - GRAUMANS, M.H.F.; VAN HOVE, H.; SCHIRRIS, T.; HOEBEN, W.F.L.M.; VAN DAEL, M.F.P.; ANZION, R.B.M.; RUSSEL, F.G.M.; SCHEEPERS, P.T.J. Determination of cytotoxicity following oxidative treatment of pharmaceutical residues in wastewater. Chemosphere, v. 303, 2022. https://doi.org/10.1016/j.chemosphere.2022.135022
» https://doi.org/10.1016/j.chemosphere.2022.135022 - HANSEN, K.M.S.; SPILIOTOPOULOU, A.; CHHETRI, R.K.; CASAS, M.E.; BESTER, K.; ANDERSEN, H.R. Ozonation for source treatment of pharmaceuticals in hospital wastewater – Ozone lifetime and required ozone dose. Chemical Engineering Journal, v. 290, p. 507-514, 2016. https://doi.org/10.1016/j.cej.2016.01.027
» https://doi.org/10.1016/j.cej.2016.01.027 - HU, J.; ZHOU, J.; ZHOU, S.; WU, P.; TSANG, Y.F. Occurrence and fate of antibiotics in a wastewater treatment plant and their biological effects on receiving waters in Guizhou. Process Safety and Environmental Protection, v.113, p. 483-490, 2018. https://doi.org/10.1016/j.psep.2017.12.003
» https://doi.org/10.1016/j.psep.2017.12.003 - JANK, L.; HOFF, R.B.; COSTA, F.J.; PIZZOLATO, T.M. Simultaneous determination of eight antibiotics from distinct classes insurface and wastewater samples by solid-phase extraction and high-performance liquid chromatography–electrospray ionization mass spectrometry. International Journal of Environmental Analytical Chemistry, v. 94, n. 10, p. 1013-1037, 2014. https://doi.org/10.1080/03067319.2014.914184
» https://doi.org/10.1080/03067319.2014.914184 - JIANG, J.L.; YUE, X.A.; CHEN, Q.F.; GAO, Z. Determination of ozonization reaction rate constants of aromatic pollutants and QSAR study. Bulletin of Environmental Contamination and Toxicology, v. 85, p. 568-572, 2010. https://doi.org/10.1007/s00128-010-0127-5
» https://doi.org/10.1007/s00128-010-0127-5 - JIANG, J.-Q.; ZHOU, Z.; SHARMA, V.K. Occurrence, transportation, monitoring and treatment of emerging micro-pollutants in waste water — A review from global views. Microchemical Journal, v. 110, p. 292-300, 2013. https://doi.org/10.1016/j.microc.2013.04.014
» https://doi.org/10.1016/j.microc.2013.04.014 - JIANG, Y.; LI, M.; GUO, C.; AN, D.; XU, J.; ZHANG, Y.; XI, B. Distribution and ecological risk of antibiotics in a typical effluent-receiving river (Wangyang River) in north China. Chemosphere, v. 112, p. 267-274, 2014. https://doi.org/10.1016/j.chemosphere.2014.04.075
» https://doi.org/10.1016/j.chemosphere.2014.04.075 - KANAKARAJU, D.; GLASS, B. D.; OELGEMÖLLER, M. Advanced oxidation process-mediated removal of pharmaceuticals from water: A review. Journal of Environmental Management, v. 219, p. 189-207, 2018. https://doi.org/10.1016/j.jenvman.2018.04.103
» https://doi.org/10.1016/j.jenvman.2018.04.103 - KATSOYIANNIS, I.A.; CANONICA, S.; VON GUNTEN, U. Efficiency and energy requirements for the transformation of organic micropollutants by ozone, O3/H2O2 and UV/H2O2 Water Research, v.45, p. 3811-3822, 2011. https://doi.org/10.1016/j.watres.2011.04.038
» https://doi.org/10.1016/j.watres.2011.04.038 - KNOPP, G.; PRASSE, C.; TERNES, T.A.; CORNEL, P. Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters. Water Research, v. 100, p. 580-592, 2016. https://doi:10.1016/j.watres.2016.04.069
» https://doi.org/10.1016/j.watres.2016.04.069 - KRISHNAN, R.Y.; MANIKANDAN, S.; SUBBAYA, R.; BIRUNTHA, M.; KARMEGAM, N. Removal of emerging micropollutants originating from pharmaceuticals and personal care products (PPCPs) in water and wastewater by advanced oxidation processes: A review. Environmental Technology & Innovation, v. 23, 2021.
- LEE, Y.; GERRITY, D.; LEE, M.; BOGEAT, A.E.; SALHI, E.; GAMAGE, S.; TRENHOLM, R.A.; WERT, E.C; SNYDER, S.A; VON GUNTEN, U. Prediction of Micropollutant Elimination during Ozonation of Municipal Wastewater Effluents: Use of Kinetic and Water Specific Information. Environmental Science & Technology, v. 47, p. 5872-5881, 2013. https://doi.org/10.1021/es400781r
» https://doi.org/10.1021/es400781r - LIM, S.; SHI, J.L.; VON GUNTEN, U.; McCURRY, D.L. Ozonation of organic compounds in water and wastewater: A critical review. Water Research, v. 213, 2022. https://doi.org/10.1016/j.watres.2022.118053
» https://doi.org/10.1016/j.watres.2022.118053 - LIN, H.; LI, H.; CHEN, L.; LI, L.; YIN, L.; LEE, H.; YANG, Z. Mass loading and emission of thirty-seven pharmaceuticals in a typical municipal wastewater treatment plant in Hunan Province, Southern China. Ecotoxicology and Environmental Safety, v. 147, p. 530-536, 2018. https://doi:10.1016/j.ecoenv.2017.08.052
» https://doi.org/10.1016/j.ecoenv.2017.08.052 - LIU, L.; WU, W.; ZHANG, J.; LV, P.; XU, L.; YAN, Y. Progress of research on the toxicology of antibiotic pollution in aquatic organisms. Acta Ecologica Sinica, v. 38, n. 1, p. 36-41, 2018. https://doi.org/10.1016/j.chnaes.2018.01.006
» https://doi.org/10.1016/j.chnaes.2018.01.006 - LOZANO, I.; PÉREZ-GUZMÁN, C.J.; MORA, A.; MAHLKNECHT, J.; AGUILAR, C.L.; CERVANTES-AVILÉS, P. Pharmaceuticals and personal care products in water streams: Occurrence, detection, and removal by electrochemical advanced oxidation processes. Science of The Total Environment, v. 827, 2022. https://doi.org/10.1016/j.scitotenv.2022.154348
» https://doi.org/10.1016/j.scitotenv.2022.154348 - LUO, S.; WEI, Z.; SPINNEY, R.; ZHANG, Z.; DIONYSIOU, D.D.; GAO, L.; CHAI, L.; WANG, D.; XIAO, R. UV direct photolysis of sulfamethoxazole and ibuprofen: an experimental and modelling study. Journal of Hazardous Materials, v. 343, p. 132-139, 2018. https://doi.org/10.1016/j.jhazmat.2017.09.019
» https://doi.org/10.1016/j.jhazmat.2017.09.019 - LUO, Y. L.; GUO, W.; NGO, H.H.; NGHIEM, L.D.; HAI, F.I.; ZHANG, J.; LIANG, S.; WANG, X.C. A review on the occurrence of micropollutants in the aquatic environment and their fate and removal during wastewater treatment. Science of the Total Environment, v. 473-474, p. 619-641, 2014. https://doi.org/10.1016/j.scitotenv.2013.12.065
» https://doi.org/10.1016/j.scitotenv.2013.12.065 - MAHMOUD, A.; FREIRE, R.S. New methods for enhancing ozone efficiency on contaminated water treatment. Química Nova, v. 30, n. 1, p. 198-205, 2007. https://doi.org/10.1590/S0100-40422007000100032
» https://doi.org/10.1590/S0100-40422007000100032 - MÁRQUEZ, G.; RODRÍGUEZ, E.M.; MALDONADO, M.I.; ÁLVAREZ, P.M. Integration of ozone and solar TiO2-photocatalytic oxidation for the degradation of selected pharmaceutical compounds in water and wastewater. Separation and Purification Technology, v. 136, p. 18-26, 2014. https://doi.org/10.1016/j.seppur.2014.08.024
» https://doi.org/10.1016/j.seppur.2014.08.024 - MARSON, E.O.; PANIAGUA, C.E.S.; GOMES JÚNIOR, O.; GONÇALVES, B.R.; SILVA, V.M.; RICARDO, I.A.; STARLING, M.C.V.M.; AMORIM, C.C.; TROVÓ, A.G. A review toward contaminants of emerging concern in Brazil: Occurrence, impact and their degradation by advanced oxidation process in aquatic matrices. Science of The Total Environment, v .836, 2022. https://doi.org/10.1016/j.scitotenv.2022.155605
» https://doi.org/10.1016/j.scitotenv.2022.155605 - MARTÍN, J.; CAMACHO-MUÑOZ, D.; SANTOS, J.L.; APARICIO, I.; ALONSO, E. Occurrence of pharmaceutical compounds in wastewater and sludge from wastewater treatment plants: removal and ecotoxicological impact of wastewater discharges and sludge disposal. Journal of Hazardous Materials, v. 239-240, p. 40-47, 2012. https://doi.org/10.1016/j.jhazmat.2012.04.068
» https://doi.org/10.1016/j.jhazmat.2012.04.068 - MARTINI, J.; ORGE, C.A.; FARIA, J.L.; PEREIRA, M.F.R.; SOARES, O.S.G.P. Sulfamethoxazole degradation by combination of advanced oxidation processes. Journal of Environmental Chemical Engineering, v. 6, n. 4, p. 4054-4060, 2018. https://doi.org/10.1016/j.jece.2018.05.047
» https://doi.org/10.1016/j.jece.2018.05.047 - MONDAL, S.K.; SAHA, A.K.; SINHA, A. Removal of ciprofloxacin using modified advanced oxidation processes: Kinetics, pathways and process optimization. Journal of Cleaner Production, v. 171, p. 1203-1214, 2018. https://doi.org/10.1016/j.jclepro.2017.10.091
» https://doi.org/10.1016/j.jclepro.2017.10.091 - QUIÑONES, D.H.; ÁLVAREZ, P.M.; REY, A.; CONTRERAS, S.; BELTRÁN, F.J. Application of solar photocatalytic ozonation for the degradation of emerging contaminants in water in a pilot plant. Chemical Engineering Journal, v. 260, p. 399-410, 2015. https://doi.org/10.1016/j.cej.2014.08.067
» https://doi.org/10.1016/j.cej.2014.08.067 - R CORE TEAM. R: A language environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria, 2016. Available at: https://r-project.org/ Accessed on: May 3, 2018.
» https://r-project.org/ - RIVAS, F.J.; BELTRÁN, F.J.; ENCINAS, A. Removal of emergent contaminants: Integration of ozone and photocatalysis. Journal of Environmental Management, v. 100, p. 10-15, 2012. https://doi.org/10.1016/j.jenvman.2012.01.025
» https://doi.org/10.1016/j.jenvman.2012.01.025 - TAOUFIK, N.; BOUMYA, W.; ACHAK, M.; SILLANPÄÄ, M.; BARKA, N. Comparative overview of advanced oxidation processes and biological approaches for the removal pharmaceuticals. Journal of Environmental Management, v. 288, 2021. https://doi.org/10.1016/j.jenvman.2021.112404
» https://doi.org/10.1016/j.jenvman.2021.112404 - VERLICCHI, P.; AL AUKIDY, M.; ZAMBELLO, E. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment-A review. Science of the Total Environment, v. 429, p. 123-155, 2012. https://doi.org/10.1016/j.scitotenv.2012.04.028
» https://doi.org/10.1016/j.scitotenv.2012.04.028 - ZIMMERMANN, S.G.; WITTENWILER, M.; HOLLENDER, J.; KRAUSS, M.; ORT, C.; SIEGRIST, H.; VON GUNTEN, U. Kinetic assessment and modeling of an ozonation step for full scale municipal wastewater treatment: Micropollutant oxidation, by-product formation and disinfection. Water Research, v. 45, n. 2, p. 605-617, 2011. https://doi.org/10.1016/j.watres.2010.07.080
» https://doi.org/10.1016/j.watres.2010.07.080
-
Funding: none.
Publication Dates
-
Publication in this collection
28 July 2023 -
Date of issue
2023
History
-
Received
02 Feb 2022 -
Accepted