Quantification of Myocardial Ischemia: Comparison between Myocardial SPECT and 13NH3 PET/TC

Keywords
Myocardial Ischemia/diagnosis; Coronary Artery Disease/diagnostic imaging; Tomography Emission- Computed Single-Photon/methods; Positron-Emission Tomography/method

Introduction

Myocardial perfusion is a very important tool to diagnose and quantify hypoperfusion related to coronary artery disease (CAD). Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a widely available nuclear medicine imaging tool. Cardiac 13N-ammonia positron emission tomography/computed tomography (13NH3 PET/CT) has increased its capability to provide quantitative measures of myocardial blood flow at rest and under stress, as well as of coronary flow reserve (CFR), in addition to better image quality.

Case report

A 61-year-old male patient with a history of hypertension, dyslipidemia and previous atrial fibrillation underwent a kidney transplant in 2001 because of post-pyelonephritic chronic kidney disease.

In 2007, in the presence of typical angina with anterior ST-depression, he underwent coronary angiography, which showed critical stenosis in the Left Anterior Descending Artery (LAD). He also underwent percutaneous transluminal coronary angioplasty (PTCA) and stenting.

From 2007 to 2017 he remained asymptomatic and all cardiac examinations he underwent did not reveal any abnormalities.

In January 2018, a treadmill stress test demonstrated ST-depression in the anterior and lateral leads that appeared only during the recovery and disappeared after 3 minutes. Therefore, he was submitted to a pharmacological stress-rest SPECT-MPI using a CZT gamma camera; an intravenous infusion of 400 µg regadenoson was performed, followed by the 99mTc-tetrofosmin injection at 7 minutes. Stress acquisition started 15-25 minutes after the radiotracer administration. Rest injection was administered 2 hours later, and images were obtained about 15-30 minutes later. Both stress and rest studies were acquired in list mode for 9 minutes using a gated 16 frame-per-cycle acquisition.

The images showed a small hypoperfusion area in the lateral wall, while it was not possible to evaluate the inferior wall because of the presence of artifacts due to persistent diaphragmatic attenuation (Figure 1). The inducible ischemia in the LCX coronary territory was reported as 16%. CFR was also evaluated during the test : it was normal in the LAD and CDX territory, whereas it was 1.58 in the LCX territory.

Figure 1
SPECT images.

A subsequent 13NH3 PET/CT study was performed to better define the perfusion and coronary blood flow measurement of the left ventricular inferior wall (Figure 2). The examination was performed again at stress and at rest with 400 µg of regadenoson and the dose was 370 MBq of 13NH3 both at stress and at rest. The PET studies were acquired in 3D and list mode for 10 minutes, starting acquisition immediately before 13NH3 injection using a Discovery PET/CT 690 (GE Healthcare, Milwaukee, Wisconsin, USA). A low-dose CT attenuation correction (140 kV, 120-150 mA) was acquired for optimal imaging position on a CT scout scan and for attenuation correction. The examination result was an increased area of inducible ischemia in the LCX coronary territory of 46%. The global CFR was also evaluated during the PET/CT test : the values were normal in the LAD and CDX territories, but pathological in the LCX territory (1,45). The patient was asymptomatic during the examination and there were no alterations in the ECG.

Figure 2
13N-NH3 PET/CT images.

Discussion

Coronary anatomy and myocardial blood flow have been identified as independent prognostic factors in patients with stable CAD.11 Douglas PS, Hoffmann U, Patel MR, Mark DB, Al-Khalidi HR, Cavanaugh B, et al. Outcomes of anatomical versus functional testing for coronary artery disease. N Engl J Med 372(14):1291-300. Frequently, these anatomical and physiological assessments are used as complementary techniques for risk stratification and clinical decision-making.22 Cremer P, Hachamovitch R, Tamarappoo B. Clinical decision making with myocardial perfusion imaging in patients with known or suspected coronary artery disease. Semin Nucl Med 44(4):320-9. Nuclear methods such as SPECT with 99mTc-tetrofosmin and cardiac PET/CT with 13NH3 are among the most frequently used tools for myocardial perfusion assessment. However, some disadvantages of the SPECT imaging related to the presence of image artifacts, long duration of the examination and the possibility of underestimating the ischemic severity in patients with multivessel disease should be considered.33 Yoshinaga K, Katoh C, Manabe O, Klein R, Naya M, Sakakibara M, et al. Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET. Circ J. 2011,75(11):2628-34. These negative issues can be avoided by using cardiac PET/CT study, which has shown high accuracy and enables the quantification of perfusion and determination of CFR, which means high sensitivity and high predictive value in coronary artery disease detection and small vessel disease.

Myocardial perfusion PET is an important and appropriate test for patients in which CFR quantification is useful for patient management.44 American Society of Nuclear Cardiology and Society of Nuclear Medicine and Moleclar Imaging Joint Statement on the Clinical Indications for Myocardial Perfusion PET. J Nucl Med, 2016;57(10):1654-6. CFR has an important impact on the prognosis of the patient: an analysis of the association between CFR and cardiac mortality suggests an excellent prognosis for a CFR > 2 and a steady increase in cardiac mortality for a CFR lower than this value.55 Murthy VL, Lee BC, Sitek A, Naya M, Moody J, Polavarapu V, et al. Comparison and progrnostic vaildation of multiple methods of quantification of myocardial blood flow with 82Rb PET. J Nucl Med. 2014;55(12):1952-8.

Much attention now is being devoted to the possibility of evaluating CFR with CZT-SPECT. This technique is very promising and recently, the WATERDAY study results were published demonstrating that the sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia in comparison with 15O-H2O PET.66 Agostini D, Roule V, Nganoa C, Roth N, Baavour R, Parienti JJ, et al. First validation of myocardial flow reserve assessed by dynamic (99m)Tc-sestamibi CZT-SPECT camera: head to head comparison with (15)O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur J Nucl Med Mol Imaging. 2018l;45(7):1079-90. Unfortunately, in our case, the results of CZT-SPECT images were not completely accurate because of the presence of diaphragmatic attenuation and the identification of a small area of inducible ischemia in the LCX territory.

Therefore, it was suggested to the patient to undergo a 13NH3 PET/CT study, which was able to better define the results of the quite unclear SPECT MPI test. The PET scan result showed an important area of inducible ischemia in the LCX coronary territory (46%) and the CFR of this territory was estimated at 1.45, which confirmed the significant diagnosis of ischemia: this information has an important impact on patient prognosis and management. We believe that this case highlights the need to perform more studies evaluating the role of CZT-SPECT in myocardial blood flow reserve assessment with a larger number of subjects using attenuation and scatter correction. Until further proven, PET results should be considered the gold standard for the quantification of myocardial blood flow.

  • Sources of Funding
    There were no external funding sources for this study.
  • Study Association
    This study is not associated with any thesis or dissertation work.
  • Ethics approval and consent to participate
    This article does not contain any studies with human participants or animals performed by any of the authors.

References

  • 1
    Douglas PS, Hoffmann U, Patel MR, Mark DB, Al-Khalidi HR, Cavanaugh B, et al. Outcomes of anatomical versus functional testing for coronary artery disease. N Engl J Med 372(14):1291-300.
  • 2
    Cremer P, Hachamovitch R, Tamarappoo B. Clinical decision making with myocardial perfusion imaging in patients with known or suspected coronary artery disease. Semin Nucl Med 44(4):320-9.
  • 3
    Yoshinaga K, Katoh C, Manabe O, Klein R, Naya M, Sakakibara M, et al. Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET. Circ J. 2011,75(11):2628-34.
  • 4
    American Society of Nuclear Cardiology and Society of Nuclear Medicine and Moleclar Imaging Joint Statement on the Clinical Indications for Myocardial Perfusion PET. J Nucl Med, 2016;57(10):1654-6.
  • 5
    Murthy VL, Lee BC, Sitek A, Naya M, Moody J, Polavarapu V, et al. Comparison and progrnostic vaildation of multiple methods of quantification of myocardial blood flow with 82Rb PET. J Nucl Med. 2014;55(12):1952-8.
  • 6
    Agostini D, Roule V, Nganoa C, Roth N, Baavour R, Parienti JJ, et al. First validation of myocardial flow reserve assessed by dynamic (99m)Tc-sestamibi CZT-SPECT camera: head to head comparison with (15)O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur J Nucl Med Mol Imaging. 2018l;45(7):1079-90.

Publication Dates

  • Publication in this collection
    08 Aug 2019
  • Date of issue
    Mar-Apr 2020

History

  • Received
    02 Oct 2018
  • Reviewed
    02 Oct 2018
  • Accepted
    26 Nov 2018
Sociedade Brasileira de Cardiologia Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil
E-mail: revistaijcs@cardiol.br